Les cookies nous permettent de vous proposer nos services plus facilement. En utilisant nos services, vous nous donnez expressément votre accord pour exploiter ces cookies.En savoir plus OK

Lenovo ThinkSystem ST550 Server (Xeon SP Gen 2) Product Guide

Lenovo ThinkSystem ST550 Server (Xeon SP Gen 2) Product Guide

Le pdf se trouve ci-dessous. Vous pouvez télécharger le pdf en cliquant à droite.

Revenir à l'accueil

 

Lenovo ThinkSystem ST550 Server (Xeon SP Gen 2)Product Guide

Abstract

The Lenovo ThinkSystem ST550 2-socket 4U rack-mountable tower server provides outstanding performance and industry-leading reliability. Now available with second-generation Intel Xeon Scalable processors, the ST550 is ideal for small-to-medium businesses, distributed enterprises, retail, educational institutions and branch offices.

This product guide provides essential presales information to understand the ThinkSystem ST550 server, its key features and specifications, components and options, and configuration guidelines. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the ST550 and consider its use in IT solutions.

Note: There are two Product Guides for the ThinkSystem ST550, as follows:

Change History

Changes in the March 17 update:

  • New models for customers in the Australia & New Zealand market
    • 7X10A0D0AU
    • 7X10A0D2AU
  • New models for customers in the EMEA market
    • 7X10A0D1EA
    • 7X10A0D3EA
    • 7X10A0D4EA
  • Added links to service videos on YouTube and Youku - Related publications and links section
  • Images are now clickable to show larger versions

Introduction

The Lenovo ThinkSystem ST550 2-socket 4U rack-mountable tower server provides outstanding performance and industry-leading reliability. It is ideal for small-to-medium businesses, distributed enterprises, retail, educational institutions, and remote/branch offices.

The ST550 server now supports second-gernation Intel Xeon Processor Scalable Family processors with up to 768 GB of TruDDR4 system memory.

Suggested uses: business workloads such as e-mail, workgroup applications, file & print, system management, web serving, and point-of-sale applications

Figure 1 shows the Lenovo ThinkSystem ST550.

Lenovo ThinkSystem ST550
Figure 1. Lenovo ThinkSystem ST550

Did you know?

The ThinkSystem ST550 is an enterprise-grade server with support for hot-swap power supplies, fans, and drives. It also offers full support of Lenovo XClarity Administrator for comprehensive systems management and includes the next generation UEFI-based Lenovo XClarity Provisioning Manager for system setup and diagnosis, and the Lenovo XClarity Controller management processor for ongoing systems management and alerting. These tools make the ST550 easy to deploy, integrate, service, and manage.

Key features

The ThinkSystem ST550 is a high-performance dual-socket tower server based on the second-generation Intel Xeon Scalable processors, supporting a wide range of processors to suit a wide range of budgets and application requirements.

Scalability and performance

The ST550 offers the following features to boost performance, improve scalability, and reduce costs:

  • Improves productivity by offering superior system performance with up to two processors, each with up to 22 cores, and core speeds up to 3.8 GHz.
  • Hyper-Threading Technology to maximize the concurrent execution of multithreaded applications, available with most processors.
  • Intelligent and adaptive system performance with energy-efficient Intel Turbo Boost Technology, available with most processors, allows CPU cores to run at maximum speeds during peak workloads by temporarily going beyond processor thermal design power (TDP).
  • Intel Virtualization Technology integrates hardware-level virtualization hooks that allow operating system vendors to better use the hardware for virtualization workloads.
  • Intel Speed Select Technology provides improvements in server utilization and guaranteed per-core performance service levels with more granular control over processor performance.
  • Intel Deep Learning Boost (Vector Neural Network Instruction set or VNNI) is designed to deliver significant, more efficient Deep Learning (Inference) acceleration for high-performance Artificial Intelligence (AI) workloads.
  • Intel Advanced Vector Extensions 512 (AVX-512) enable acceleration of enterprise-class workloads, including databases and enterprise resource planning (ERP).
  • Each processor has six memory channels with memory speeds of up to 2933 MHz to help maximize system performance
  • Up to 768 GB of memory capacity using 12x 64GB DIMMs
  • The 12 Gbps SAS internal storage connectivity doubles the data transfer rate compared to 6 Gb SAS solutions to maximize performance of storage I/O-intensive applications.
  • Flexible storage configurations support either 2.5-inch or 3.5-inch hot-swap drive bays or a combination of the two (hybrid configuration). Configurations with 3-5-inch simple-swap drive bays are also available. 
    • Up to 16x 2.5-inch drive bays with two 5.25-inch media drive bays available
    • Up to 20x 2.5-inch drive bays with the media bays converted to 4x 2.5-inch drive bays
    • Up to 8x 3.5-inch drive bays with two 5.25-inch media drive bays available
    • Up to 8x 3.5-inch + 4x 2.5-inch drive bays with the media bay conversion
    • Up to 8x 3.5-inch simple-swap drive bays
  • 3.5-inch drive bays support SAS and SATA HDDs and SSDs. 2.5-inch drive bays support SAS and SATA HDDs and SSDs, as well as NVMe drives.
  • Support for up to four NVMe PCIe SSDs in a 2.5-inch form factor maximizes drive I/O performance, in terms of throughput, bandwidth, and latency.
  • The use of solid-state drives (SSDs) instead of, or along with, traditional hard disk drives (HDDs) can significantly improve I/O performance. An SSD can support up to 100 times more I/O operations per second (IOPS) than a typical HDD.
  • New high-speed RAID controllers from Broadcom provide 12 Gb SAS connectivity to the drive backplanes. A variety of RAID adapters are available, with cache up to 4 GB and support for 20 drives on a single controller.
  • Supports a new Lenovo patented-design M.2 adapter for convenient operating system boot functions. Available M.2 adapters support either one M.2 drive or two M.2 drives in a RAID 1 configuration for greater boot drive performance and reliability.
  • The server has two integrated Gigabit Ethernet ports.
  • The server offers PCI Express 3.0 I/O expansion capabilities that improve the theoretical maximum bandwidth by almost 100% (8 GT/ps per link using 128b/130b encoding) compared to the previous generation of PCI Express 2.0 (5 GT/s per link using 8b/10b encoding).
  • The server offers up to six PCIe 3.0 I/O expansion slots plus one slot reserved for the M.2 adapter
  • Support for up to two NVIDIA graphics processing units (GPUs) to maximize computing power.

Availability and serviceability

The ST550 provides the following features to simplify serviceability and increase system uptime:

  • The server offers Single Device Data Correction (SDDC, also known as Chipkill), Adaptive Double- Device Data Correction (ADDDC, also known as Redundant Bit Steering or RBS), memory mirroring, and memory rank sparing for redundancy in the event of a non-correctable memory failure.
  • The server offers hot-swap (HS) SSDs and HDDs, and supports RAID redundancy for data protection and greater system uptime.
  • Much like HS drives, simple-swap drives are mounted on an easy-to-remove tray and work with the same RAID options. Simple-swap require a system power-down before adding or replacing, however simple-swap drives are less expensive than hot-swap drives.
  • The Dual M.2 Boot Adapter supports RAID-1 which enables two installed M.2 drives to be configured as a redundant pair.
  • The server supports hot-swap power supplies; with two installed, they form a redundant pair to provide availability for business-critical applications. The server also offers an optional 4th fan which offers redundancy in most server configurations.
  • Toolless cover removal provides easy access to upgrades and serviceable parts, such as CPU, memory, and adapter cards.
  • Proactive Platform Alerts (including PFA and SMART alerts) for: processors, voltage regulators, memory, internal storage (SAS/SATA HDDs and SSDs), fans, power supplies, RAID controllers, and server ambient and sub-component temperatures. Alerts can be surfaced through the XClarity Controller management processor to managers such as Lenovo XClarity Administrator, VMware vCenter, and Microsoft System Center. These proactive alerts let you take appropriate actions in advance of possible failure, thereby increasing server uptime and application availability.
  • SSDs, with no moving parts, offer significantly better reliability than mechanical HDDs, for greater uptime.
  • The built-in XClarity Controller continuously monitors system parameters, triggers alerts, and performs recovery actions in case of failures to minimize downtime.
  • Built-in diagnostics in UEFI, using Lenovo XClarity Provisioning Manager, speed up troubleshooting tasks to reduce service time.
  • Lenovo XClarity Provisioning Manager supports diagnostics and can save service data to a USB key drive or remote CIFS share folder for troubleshooting and reduce service time.
  • Auto restart in the event of a momentary loss of AC power (based on power policy setting in the XClarity Controller service processor)
  • Support for the XClarity Administrator Mobile app running on a supported smartphone and connected to the server through the service-enabled USB port, enables additional local systems management functions.
  • Three-year or one-year customer-replaceable unit and onsite limited warranty, 9 x 5 next business day. Optional service upgrades are available.

Manageability and security

The following powerful systems management features simplify local and remote management of the ST550:

  • The server includes an XClarity Controller (XCC) to monitor server availability. Optional upgrade to XCC Advanced to provide remote control (keyboard video mouse) functions. Optional upgrade to XCC Enterprise enables the additional support for the mounting of remote media files (ISO and IMG image files), boot capture, and power capping.
  • Lenovo XClarity Administrator offers comprehensive hardware management tools that help to increase uptime, reduce costs and improve productivity through advanced server management capabilities.
  • New UEFI-based Lenovo XClarity Provisioning Manager, accessible from F1 during boot, provides system inventory information, graphical UEFI Setup, platform update function, RAID Setup wizard, operating system installation function, and diagnostic functions.
  • Support for Lenovo XClarity Energy Manager which captures real-time power and temperature data from the server and provides automated controls to lower energy costs.
  • Integrated Trusted Platform Module (TPM) 2.0 support enables advanced cryptographic functionality, such as digital signatures and remote attestation.
  • Supports Secure Boot to ensure that only a digitally signed operating system can be used. Supported with HDDs and SSDs as well as M.2 drives in the M.2 Adapter.
  • Industry-standard Advanced Encryption Standard (AES) NI support for faster, stronger encryption.
  • Intel Execute Disable Bit functionality can prevent certain classes of malicious buffer overflow attacks when combined with a supported operating system.
  • Intel Trusted Execution Technology provides enhanced security through hardware-based resistance to malicious software attacks, allowing an application to run in its own isolated space, protected from all other software running on a system.
  • Physical security measures to prevent unauthorized access: Lockable side cover to prevent access to internal components, a slot at the rear of the server for a Kensington Cable. Optional additional physical security features are a lockable front security door and a chassis intrusion switch (included in some models).

Energy efficiency

The ST550 offers the following energy-efficiency features to save energy, reduce operational costs, increase energy availability, and contribute to the green environment:

  • Energy-efficient planar components help lower operational costs.
  • High-efficiency power supplies with 80 PLUS Platinum and Titanium certifications. Energy Star 2.1 certified.
  • Intel Intelligent Power Capability powers individual processor elements on and off as needed to reduce power draw.
  • Low-voltage 1.2 V DDR4 memory DIMMs use up to 20% less energy compared to 1.35 V DDR3 DIMMs.
  • SSDs use as much as 80% less power than traditional spinning 2.5-inch HDDs.
  • The server uses hexagonal ventilation holes, which can be grouped more densely than round holes, providing more efficient airflow through the system.
  • Optional Lenovo XClarity Energy Manager provides advanced data center power notification, analysis, and policy-based management to help achieve lower heat output and reduced cooling needs.

Components and connectors

The following figure shows the front of the server.

Front view of the ThinkSystem ST550 server
Figure 2. Front view of the ThinkSystem ST550 server

The following figure shows the rear of the server.

Rear view of the ThinkSystem ST550 server
Figure 3. Rear view of the ThinkSystem ST550 server

The following figure shows the locations of key components inside the server.

Internal view of the ThinkSystem ST550 server
Figure 4. Internal view of the ThinkSystem ST550 server

System architecture

The following figure shows the architectural block diagram of the ST550, showing the major components and their connections.

ST550 system architectural block diagram
Figure 5. ST550 system architectural block diagram

Standard specifications

The following table lists the standard specifications.

Table 1. Standard specifications
Components Specification
Machine type 7X09 - 1 year warranty
7X10 - 3 year warranty
Form factor Tower or 4U Rack.
Processor One or two second-generation Intel Xeon Processor Scalable Family of processors, either Bronze, Silver, Gold or Platinum-level processors (formerly codename "Cascade Lake"). Supports processors up to 22 cores, core speeds up to 3.8 GHz, and TDP ratings up to 125W. Two Intel Ultra Path Interconnect (UPI) links at 10.4 GT/s each.
Chipset Intel C624 "Lewisburg" chipset
Memory Up to 12 DIMM sockets (6 DIMMs per processor) supporting Lenovo TruDDR4 DIMMs at up to 2933 MHz. RDIMMs and LRDIMMs (Load Reduced DIMMs) are supported, but memory types cannot be intermixed.
Memory maximums Up to 768 GB with 12x 64 GB RDIMMs and two processors
Memory protection ECC, SDDC (for x4-based memory DIMMs), ADDDC (for x4-based memory DIMMs, requires Intel Xeon Gold or Platinum processors), memory mirroring, and memory sparing.
Disk drive bays

Available configurations:

  • 8, 16, or 20x 2.5-inch SAS/SATA hot-swap (optional support for NVMe drives)
  • 4 or 8x 3.5-inch SAS/SATA hot-swap
  • Both 8x 3.5-inch + 4x 2.5-inch SAS/SATA hot-swap
  • 4 or 8x 3.5-inch SATA simple-swap
Additional drive bays (except for 20-bay and hybrid configurations):
  • Two 5.25-inch drive bays for optical drives
Maximum internal storage
  • 153.6 TB with 20x 7.68TB 2.5-inch SAS hot-swap SSDs
  • 142.7 TB with 8x 14TB 3.5-inch HDDs + 4x 7.68TB 2.5-inch SSDs
  • 112 TB with 8x 14TB 3.5-inch NL SAS or NL SATA hot-swap HDDs
  • 80 TB with 8x 10TB 3.5-inch NL SAS or NL SATA simple-swap HDDs
  • Intermix of SAS and SATA is supported.
Storage controller
  • Onboard 6 Gb SATA for simple-swap drive configurations, using embedded Intel RSTe software RAID, supporting RAID 0, 1, 10, 5, 50
  • 12 Gb SAS/SATA RAID for hot-swap drive configurations:
    • RAID 530i (cacheless) supports RAID 0, 1, 10, 5, 50
    • RAID 730-8i with 1GB cache supports RAID 0, 1, 10, 5, 50
    • RAID 730-8i with 2GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
    • RAID 930-8i with 2GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
    • RAID 930-16i and 24i with 4GB flash-backed cache supports RAID 0, 1, 10, 5, 50, 6, 60
  • 12 Gb SAS/SATA non-RAID: 430-8i and 430-16i HBAs
Optical drive bays Two half-height 5.25-inch bays for optical or tape drives. Supports DVD-ROM or Multiburner. Hot-swap bays can be converted to 4x 2.5-inch hot-swap drive bays. (Not available with simple-swap drive configurations.)
Tape drive bays Two half-height 5.25-inch bays for optical or tape drives. Support for one RDX drive or LTO tape drive.
Network interfaces Two integrated Gigabit Ethernet 1000BASE-T ports (RJ-45) based on Intel X722 embedded controller (No 10/100 Mbps support)
PCI Expansion slots Up to 7 PCIe slots: 6 general purpose PCIe 3.0 slots plus one slot reserved for the M.2 adapter. General purpose slots are as follows:
  • Slot 1: PCIe 3.0 x8 (25W) FHHL
  • Slot 2: PCIe 3.0 x16 (75W); FHHL
  • Slot 3: PCIe 3.0 x16 (75W); FHFL
  • Slot 4: PCIe 3.0 x16 (x8 wired) (25W); FHFL (requires second processor)
  • Slot 5: PCIe 3.0 x16 (75W); FHFL (requires second processor)
  • Slot 6: PCIe 3.0 x8 (x4 wired) (25W); FHFL

Slots 3 and 5 support double-wide GPUs

Ports
  • Front: Two USB ports (one USB 3.0, one USB 2.0 port
  • Rear: Six USB ports (four USB 2.0, two USB 3.0), one VGA video, one RJ-45 systems management, two RJ-45 GbE network ports, optional serial port.
  • Internal: One internal USB 3.0 port for RDX drive
Cooling Supports ASHRAE A2 environments as well as A3/A4 with some limitations. Up to four simple-swap fans: two fans shipped standard on single processor models and three fans shipped on dual processor models or models where there are drive bays in lieu of the optical drive bays. The fourth rear-mounted fan is N+1 redundant, except for certain configurations.
Power supply Up to two redundant hot-swap 550 W, 750 W or 1100 W High Efficiency Platinum AC power supplies, or 750 W High Efficiency Titanium AC power supplies. Also available is a 450 W fixed (non-hot-swap) power supply. In China only, all hot-swap power supplies also support 240V DC.
Hot-swap parts Hard drives, power supplies, and fans
Systems management Operator panel with status LEDs. XClarity Controller embedded management, XClarity Administrator centralized infrastructure delivery, XClarity Integrator plugins, and XClarity Energy Manager centralized server power management. Optional XClarity Controller Advanced to enable remote control functions.
Security features Power-on password, administrator's password, Trusted Platform Module (TPM), supporting TPM 1.2 or TPM 2.0. In China only, optional Trusted Cryptographic Module (TCM). Kensington cable slot. Lockable side cover. Optional lockable front security door and chassis intrusion switch (included with some models).
Video G200 graphics with 16 MB memory with 2D hardware accelerator, integrated into the XClarity Controller. Maximum resolution is 1920x1200 32bpp at 60Hz.
Operating systems supported Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server, VMware ESXi. See the Operating system support section for specifics.
Limited warranty Three-year or one-year (model dependent) customer-replaceable unit and onsite limited warranty with 9x5 next business day (NBD).
Service and support Optional service upgrades are available through Lenovo Services: 4-hour or 2-hour response time, 6-hour fix time, 1-year or 2-year warranty extension, software support for Lenovo hardware and some third-party applications.
Dimensions Tower: width, without foot stands: 176 mm (6.9 in), width, with foot stands: 272 mm (10.7 in), depth: 670 mm (26.4 in), height: 438 mm (17.2 in). With rack conversion kit: Width: 482 mm (18.97 inches), depth: 670 mm (26.4 in), height: 176 mm (6.9 in)
Weight Fully configured: 36 kg (79.36 lb)

Models

The following tables list the available models, grouped by region.

Refer to the Specifications section for information about standard features of the server.

Common to all models:

  • All models indicated as having the 750W power supply are using the Platinum power supply.

Models for Australia and New Zealand

Table 2. Models for Australia and New Zealand
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
Standard models
7X10A0AHAU 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0AJAU 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09WAU 1x Silver 4209T 8C 70W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0A6AU 1x Silver 4209T 8C 70W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09XAU 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0AGAU 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0ABAU 1x Silver 4214 12C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0AEAU 1x Silver 4214 12C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0ADAU 1x Silver 4214Y 12/10/8C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0AFAU 1x Silver 4214Y 12/10/8C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0A1AU 1x Silver 4215 8C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0A4AU 1x Silver 4215 8C 85W 2.5GHz 1x 32GB 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0ACAU 1x Silver 4215 8C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0AMAU 1x Silver 4215 8C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0A3AU 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0A8AU 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0ANAU 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09ZAU 1x Gold 5217 8C 115W 3.0GHz 1x 32GB 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0A0AU 1x Gold 5218 16C 125W 2.3GHz 1x 32GB 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
TopSeller models
7X10A09YAU 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 2Rx8 2933 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0A7AU 1x Bronze 3204 6C 85W 1.9GHz 1x 32GB 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0A9AU 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0AAAU 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0D0AU 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2666 930-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0A2AU 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0A5AU 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2933 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0AKAU 1x Silver 4210 10C 85W 2.2GHz 1x 32GB 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0ALAU 1x Silver 4210 10C 85W 2.2GHz 1x 32GB 2933 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No
7X10A0D2AU 1x Silver 4214 12C 85W 2.2GHz 1x 16GB 2Rx8 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Ent No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for South East Asian countries (ASEAN)

Table 3. Models for South East Asian countries (ASEAN)
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
Standard models
7X10A080SG 1x Gold 5215 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09MSG 1x Gold 5215 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08CSG 1x Gold 5215L 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09HSG 1x Gold 5215L 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07KSG 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08KSG 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07NSG 1x Gold 5220 18C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A086SG 1x Gold 5220 18C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07QSG 1x Gold 5222 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A082SG 1x Gold 5222 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07JSG 1x Gold 6230 20C 125W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A090SG 1x Gold 6230 20C 125W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08HSG 1x Gold 6238T 22C 125W 1.9GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08LSG 1x Gold 6238T 22C 125W 1.9GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08DSG 1x Platinum 8253 16C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09RSG 1x Platinum 8253 16C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09LSG 1x Platinum 8256 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09TSG 1x Platinum 8256 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for Brazil

Table 4. Models for Brazil
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
TopSeller models
7X10A0BMBR 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 1Rx4 2933 730-8i 1GB 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Std No
7X10A0BLBR 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 1Rx4 2933 730-8i 1GB 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Std No
7X10A0BNBR 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 1Rx4 2933 530-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Std No
SAP Business One models with SLES for SAP Applications 2 Socket Priority Subscription with 1-Year Lenovo Support
7X10A0C5BR 2x Silver 4210 10C 85W 2.2GHz 12x 8GB 2933 930-16i 16x 2.5" HS / 16 4x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0C6BR 2x Silver 4210 10C 85W 2.2GHz 12x 16GB 2Rx8 2933 930-16i 16x 2.5" HS / 16 4x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0C7BR 2x Silver 4210 10C 85W 2.2GHz 12x 32GB 2933 930-16i 16x 2.5" HS / 16 5x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0C8BR 2x Silver 4214 12C 85W 2.2GHz 12x 64GB 2933 930-16i 16x 2.5" HS / 16 6x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for EMEA countries

Table 5. Models for EMEA countries
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
Standard models
7X10A0CREA 1x Bronze 3206R 8C 85W 1.9GHz 1x 16GB 2Rx8 2933 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS Yes Std No
7X10A07AEA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2666 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS No Std No
7X10A07SEA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 1100W HS No Ent No
7X10A07TEA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2666 930-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 1100W HS No Ent No
7X10A0B5EA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS No Ent No
7X10A0CMEA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0CTEA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS Yes Std No
7X10A0CWEA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0CXEA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS Yes Std No
7X10A07GEA 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS No Std No
7X10A092EA 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2666 930-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09PEA 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2666 930-8i 8x 2.5" HS / 20** 2x 600GB 10K Open 8 / 11 2x 750W HS No Std No
7X10A09VEA 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2666 930-8i 8x 2.5" HS / 20** 2x 480GB PM883 Open 8 / 11 2x 550W HS No Std No
7X10A0CLEA 1x Silver 4210R 10C 100W 2.4GHz 1x 16GB 2Rx8 2933 930-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0CQEA 1x Silver 4210R 10C 100W 2.4GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** 2x 480GB PM883 Open 8 / 11 2x 550W HS Yes Std No
7X10A0CSEA 1x Silver 4210R 10C 100W 2.4GHz 1x 16GB 2Rx8 2933 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS Yes Std No
7X10A0CVEA 1x Silver 4210R 10C 100W 2.4GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS Yes Std No
7X10A0D1EA 1x Silver 4210R 10C 100W 2.4GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0D3EA 1x Silver 4210R 10C 100W 2.4GHz 1x 16GB 2Rx8 2933 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Std No
7X10A0D4EA 1x Silver 4210R 10C 100W 2.4GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Std No
7X10A07FEA 1x Silver 4214 12C 85W 2.2GHz 1x 16GB 2Rx8 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS No Std No
7X10A0CYEA 1x Silver 4214R 12C 100W 2.4GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A09SEA 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 2Rx8 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 550W HS No Std No
7X10A0CPEA 1x Gold 5218R 20C 125W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for Hong Kong, Taiwan, Korea (HTK)

Table 6. Models for Hong Kong, Taiwan, Korea (HTK)
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
Standard models
7X10A07ZCN 1x Gold 5215 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A097CN 1x Gold 5215 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A091CN 1x Gold 5215L 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09NCN 1x Gold 5215L 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08NCN 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08XCN 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A078CN 1x Gold 5220 18C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07XCN 1x Gold 5220 18C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08WCN 1x Gold 5222 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A094CN 1x Gold 5222 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07ECN 1x Gold 6230 20C 125W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07WCN 1x Gold 6230 20C 125W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A079CN 1x Gold 6238T 22C 125W 1.9GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09CCN 1x Gold 6238T 22C 125W 1.9GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09ACN 1x Platinum 8253 16C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09KCN 1x Platinum 8253 16C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08MCN 1x Platinum 8256 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A093CN 1x Platinum 8256 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
TopSeller models
7X10A0CACN 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CGCN 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CBCN 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CKCN 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CCCN 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CJCN 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CDCN 1x Silver 4214 12C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CHCN 1x Silver 4214 12C 85W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CECN 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A0CFCN 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for India

Table 7. Models for India
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
Standard models
7X10A085SG 1x Gold 5215 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09BSG 1x Gold 5215 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08PSG 1x Gold 5215L 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08ZSG 1x Gold 5215L 10C 85W 2.5GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08VSG 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A09GSG 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08BSG 1x Gold 5220 18C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A098SG 1x Gold 5220 18C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A081SG 1x Gold 5222 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A096SG 1x Gold 5222 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A084SG 1x Gold 6230 20C 125W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08ASG 1x Gold 6230 20C 125W 2.1GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07CSG 1x Gold 6238T 22C 125W 1.9GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08FSG 1x Gold 6238T 22C 125W 1.9GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08RSG 1x Platinum 8253 16C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A099SG 1x Platinum 8253 16C 125W 2.2GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No
7X10A07YSG 1x Platinum 8256 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS No Std No
7X10A08YSG 1x Platinum 8256 4C 105W 3.8GHz 1x 16GB 2Rx8 2933 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS No Std No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for Japan

Table 8. Models for Japan
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
Topseller Models
7X10A08JJP 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 550W HS Yes Adv Yes
7X10A09FJP 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 1Rx4 2666 730-8i 2GB 4x 3.5" HS / 8 Open bay 1x DVD-ROM 8 / 11 1x 550W HS Yes Adv Yes
7X10A08QJP 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 550W HS Yes Adv Yes
7X10A09DJP 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 550W HS Yes Adv Yes
7X10A09EJP 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 1Rx4 2666 730-8i 2GB 4x 3.5" HS / 8 Open bay 1x DVD-ROM 8 / 11 1x 550W HS Yes Adv Yes
7X10A07DJP 1x Silver 4214 12C 85W 2.2GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 550W HS Yes Adv Yes
7X10A08UJP 1x Silver 4215 8C 85W 2.5GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 550W HS Yes Adv Yes
7X10A07MJP 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 1Rx4 2666 730-8i 2GB 4x 3.5" HS / 8 Open bay 1x DVD-ROM 8 / 11 1x 750W HS Yes Adv Yes
7X10A08EJP 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 750W HS Yes Adv Yes
7X10A07RJP 1x Gold 5215 10C 85W 2.5GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 750W HS Yes Adv Yes
7X10A07VJP 1x Gold 5217 8C 115W 3.0GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 750W HS Yes Adv Yes
7X10A087JP 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 750W HS Yes Adv Yes
7X10A089JP 1x Gold 5220 18C 125W 2.2GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 750W HS Yes Adv Yes
7X10A07LJP 1x Gold 5222 4C 105W 3.8GHz 1x 16GB 1Rx4 2666 730-8i 2GB 8x 2.5" HS / 16 Open bay 1x DVD-ROM 8 / 11 1x 750W HS Yes Adv Yes

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for Latin American countries (except Brazil)

Table 9. Models for Latin American countries (except Brazil)
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
TopSeller models
7X10A0BGLA 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 1Rx4 2933 730-8i 1GB 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Std No
7X10A0BJLA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 1Rx4 2933 730-8i 1GB 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Std No
SAP Business One models with SLES for SAP Applications 2 Socket Priority Subscription with 1-Year Lenovo Support
7X10A0BTLA 2x Silver 4210 10C 85W 2.2GHz 12x 8GB 2933 930-16i 16x 2.5" HS / 16 4x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0BULA 2x Silver 4210 10C 85W 2.2GHz 12x 16GB 2Rx8 2933 930-16i 16x 2.5" HS / 16 4x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0BVLA 2x Silver 4210 10C 85W 2.2GHz 12x 32GB 2933 930-16i 16x 2.5" HS / 16 5x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0BXLA 2x Silver 4210 10C 85W 2.2GHz 12x 8GB 2933 930-16i 16x 2.5" HS / 16 4x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0BYLA 2x Silver 4210 10C 85W 2.2GHz 12x 16GB 2Rx8 2933 930-16i 16x 2.5" HS / 16 4x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0BZLA 2x Silver 4210 10C 85W 2.2GHz 12x 32GB 2933 930-16i 16x 2.5" HS / 16 5x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0C1LA 2x Silver 4210 10C 85W 2.2GHz 12x 8GB 2933 930-16i 16x 2.5" HS / 16 4x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0C2LA 2x Silver 4210 10C 85W 2.2GHz 12x 16GB 2Rx8 2933 930-16i 16x 2.5" HS / 16 4x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0C3LA 2x Silver 4210 10C 85W 2.2GHz 12x 32GB 2933 930-16i 16x 2.5" HS / 16 5x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0BWLA 2x Silver 4214 12C 85W 2.2GHz 12x 64GB 2933 930-16i 16x 2.5" HS / 16 6x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0C0LA 2x Silver 4214 12C 85W 2.2GHz 12x 64GB 2933 930-16i 16x 2.5" HS / 16 6x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No
7X10A0C4LA 2x Silver 4214 12C 85W 2.2GHz 12x 64GB 2933 930-16i 16x 2.5" HS / 16 6x S4610 960GB 1x DVD-RW 8 / 11 2x 750W HS Yes Ent No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Models for USA and Canada

Table 10. Models for USA and Canada
Model Intel Xeon
processors†
Memory RAID Drive bays
Drives
Optical Slots Power supplies
Power
cords
XCC
Level
Physical
security‡
Standard models
7X10A0ARNA 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 1Rx4 2666 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0ASNA 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 1Rx4 2666 530-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0ATNA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 1Rx4 2666 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0AZNA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 1Rx4 2666 530-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0B2NA 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 1Rx4 2666 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0B0NA 1x Silver 4214 12C 85W 2.2GHz 1x 16GB 1Rx4 2666 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0AWNA 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 1Rx4 2666 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0AVNA 1x Gold 5218 16C 125W 2.3GHz 1x 16GB 1Rx4 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0AYNA 1x Gold 5220 18C 125W 2.2GHz 1x 16GB 1Rx4 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
TopSeller models
7X10A0APNA 1x Bronze 3204 6C 85W 1.9GHz 1x 16GB 1Rx4 2666 530-8i 4x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0BHNA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 1Rx4 2666 530-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0BKNA 1x Silver 4208 8C 85W 2.1GHz 1x 16GB 1Rx4 2666 530-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0AQNA 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 1Rx4 2666 530-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0B3NA 1x Silver 4210 10C 85W 2.2GHz 1x 16GB 1Rx4 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0AUNA 1x Silver 4216 16C 100W 2.1GHz 1x 32GB 2666 930-8i 8x 3.5" HS / 8* Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0B1NA 1x Silver 4216 16C 100W 2.1GHz 1x 16GB 1Rx4 2666 930-8i 8x 2.5" HS / 20** Open bay Open 8 / 11 1x 750W HS Yes Ent No
7X10A0AXNA 1x Gold 5218 16C 125W 2.3GHz 1x 32GB 2666 930-16i 16x 2.5" HS / 16* Open bay Open 8 / 11 1x 750W HS Yes Ent No

† Processor detail: Quantity, model, core count, TDP, core frequency
** 20 drive bays includes 4x 2.5" HS drive bays with media bay conversion
* Additionally supports 4x 2.5" HS drive bays with media bay conversion
‡ Physical security includes both security door & intrusion switch

Processor options

The ST550 supports the Bronze, Silver, Gold, and Platinum level processors in the family of second-generation Intel Xeon Scalable processors. The server supports the processor options that are listed in the following table. The server supports up to two processors.

First generation processors: The ST550 also supports first-generation Xeon Scalable processors. For details, see https://lenovopress.com/lp0648.

All processors listed above have the following characteristics:

  • Second-generation Intel Xeon Scalable processors (formerly codenamed "Cascade Lake")
  • 14 nm process technology
  • Six DDR4 memory channels
  • 48 PCIe 3.0 I/O lanes
  • 1 MB L2 cache
  • 1.375 MB or more L3 cache per core
  • Intel Hyper-Threading Technology (except Bronze processors)
  • Intel Turbo Boost Technology 2.0 (except Bronze processors)
  • Intel Advanced Vector Extensions 512 (AVX-512)
  • Two Intel Ultra Path Interconnect (UPI) links at up to 10.4 GT/s

Some processors include a suffix letter in the processor model number:

  • L: Large memory tier (supports total memory up to 4.5TB)
  • M: Medium memory tier (supports total memory up to 2TB)
  • N: NFV optimized
  • S: Search optimized
  • T: High Tcase
  • U: Single socket
  • V: VM Density optimized
  • Y: Speed Select

Tip: B is not an official suffix, but instead used by Intel to distinguish between the Xeon Gold 5218 and the Xeon Gold 5218B processors. These two processor models have the same core counts, frequencies, and features, however they are based on different die configurations. You should not install 5218 and 5218B processors in the same server.

Tip: The option part numbers listed in the table below includes the processor heatsink and an additional system fan.

Table 11. Second-generation Intel Xeon Scalable processor selections
Part number* Feature code Description Maximum
supported
4XG7A14813 B4HU Intel Xeon Bronze 3204 6C 85W 1.9GHz Processor 2
4XG7A37997 B7N3 Intel Xeon Bronze 3206R 8C 85W 1.9GHz Processor 2
4XG7A14812 B4HT Intel Xeon Silver 4208 8C 85W 2.1GHz Processor 2
4XG7A14881 B4P4 Intel Xeon Silver 4209T 8C 70W 2.2GHz Processor 2
4XG7A14811 B4HS Intel Xeon Silver 4210 10C 85W 2.2GHz Processor 2
4XG7A37995 B7N5 Intel Xeon Silver 4210R 10C 100W 2.4GHz Processor 2
4XG7A14810 B4HR Intel Xeon Silver 4214 12C 85W 2.2GHz Processor 2
4XG7A37994 B7N6 Intel Xeon Silver 4214R 12C 100W 2.4GHz Processor 2
4XG7A14840 B4NW Intel Xeon Silver 4214Y 12/10/8C 85W 2.2GHz Processor 2
4XG7A14809 B4HQ Intel Xeon Silver 4215 8C 85W 2.5GHz Processor 2
4XG7A14808 B4HP Intel Xeon Silver 4216 16C 100W 2.1GHz Processor 2
4XG7A14807 B4HN Intel Xeon Gold 5215 10C 85W 2.5GHz Processor 2
4XG7A15698 B4P9 Intel Xeon Gold 5215L 10C 85W 2.5GHz Processor 2
4XG7A14860 B4P1 Intel Xeon Gold 5215M 10C 85W 2.5GHz Processor 2
4XG7A14806 B4HM Intel Xeon Gold 5217 8C 115W 3.0GHz Processor 2
4XG7A14805 B4HL Intel Xeon Gold 5218 16C 125W 2.3GHz Processor 2
4XG7A15786 B6BS Intel Xeon Gold 5218B 16C 125W 2.3GHz Processor 2
4XG7A15730 B5S0 Intel Xeon Gold 5218N 16C 105W 2.3GHz Processor 2
4XG7A63302 BAZS Intel Xeon Gold 5218R 20C 125W 2.1GHz Processor 2
4XG7A37972 B4P3 Intel Xeon Gold 5218T 16C 105W 2.1GHz Processor 2
4XG7A14804 B4HK Intel Xeon Gold 5220 18C 125W 2.2GHz Processor 2
4XG7A15860 B6CW Intel Xeon Gold 5220S 18C 125W 2.7GHz Processor 2
4XG7A15858 B6CQ Intel Xeon Gold 5220T 18C 105W 1.9GHz Processor 2
4XG7A15754 B5S1 Intel Xeon Gold 5222 4C 105W 3.8GHz Processor 2
None** B6CX Intel Xeon Gold 6209U 20C 125W 2.1GHz Processor 1**
4XG7A15859 B6CV Intel Xeon Gold 6222V 20C 115W 1.8GHz Processor 2
4XG7A15856 B6CL Intel Xeon Gold 6226 12C 125W 2.7GHz Processor 2
4XG7A14803 B4HJ Intel Xeon Gold 6230 20C 125W 2.1GHz Processor 2
4XG7A15857 B6CP Intel Xeon Gold 6230T 20C 125W 2.1GHz Processor 2
4XG7A14867 B4P2 Intel Xeon Gold 6238T 22C 125W 1.9GHz Processor 2
4XG7A15746 B5RZ Intel Xeon Platinum 8253 16C 125W 2.2GHz Processor 2
4XG7A15739 B5S2 Intel Xeon Platinum 8256 4C 105W 3.8GHz Processor 2

* Option part numbers include the processor heatsink and an additional system fan.
** The 6209U processor is only supported one processor per server; as a result, there is no option part number for a second processor.

Memory capacity of processors

Second-generation Xeon Scalable processors are limited to the amount of memory they can address, as follows:

  • Processors with an L suffix (eg 8280L): Up to 4.5 TB per processor
  • Processors with an M suffix (eg 8280M): Up to 2 TB per processor
  • All other processors: Up to 1 TB per processor

The calculation is based on each processor individually, not the total memory installed in the server. For example, a configuration using 12x 64GB DIMMs per server is 6x 64 GB per processor, which is 384 GB per processor. This means that neither an M nor an L processor is required

Tip: There are no memory configurations of the ST550 that require an L-suffix or an M-suffix processor.

Processor features

The following table compares the features of the supported second-generation Intel Xeon processors.

Abbreviations used in the table:

  • UPI: Ultra Path Interconnect
  • TDP: Thermal Design Power
  • FMA: Number of Intel AVX-512 Fused-Multiply Add (FMA) units
  • HT: Hyper-Threading
  • TB: Turbo Boost 2.0
  • VT: Virtualization Technology (includes VT-x and VT-d)
  • SST-PP: Speed Select Technology - Performance Profile
  • DCPMM: DC Persistent Memory Module support
  • RAS: Reliability, Availability, and Serviceability: Std = Standard, Adv = Advanced

The processors that support SST-PP offer three distinct operating points that are defined by a core count with a base speed associated with that core count. The operating point is selected during the boot process and cannot be changed at runtime.

Table 12. Processor specifications
CPU
model
Cores /
threads
Core speed
(Base / TB max)
L3 cache* Max
memory
speed
Max
memory
per CPU
UPI links
& speed
FMA
units
TDP
HT
TB
VT
SST-PP
DCPMM
RAS
Intel Xeon 3200 (Bronze) processors
3204 6 / 6 1.9 / None 8.25 MB 2133 MHz 1 TB 2, 9.6 GT/s 1 85 W N N Y N N Std
3206R 8 / 8 1.9 GHz / None 11 MB 2133 MHz 1 TB 2, 9.6 GT/s 1 85 W N N Y N N Std
Intel Xeon 4200 (Silver) processors
4208 8 / 16 2.1 / 3.2 GHz 11 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 85 W Y Y Y N N Std
4209T 8 / 16 2.2 / 3.2 GHz 11 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 70 W Y Y Y N N Std
4210 10 / 20 2.2 / 3.2 GHz 13.75 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 85 W Y Y Y N N Std
4210R 10 / 20 2.4 / 3.2 GHz 13.75 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 100 W Y Y Y N N Std
4214 12 / 24 2.2 / 3.2 GHz 16.5 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 85 W Y Y Y N N Std
4214R 12 / 24 2.4 / 3.5 GHz 16.5 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 100 W Y Y Y N N Std
4214Y 12 / 24 2.2 / 3.2 GHz 16.5 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 85 W Y Y Y Y N Std
10 / 20 2.3 / 3.2 GHz
8 / 16 2.4 / 3.2 GHz
4215 8 / 16 2.5 / 3.5 GHz 11 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 85 W Y Y Y N Y Std
4215R 8 / 16 3.2 / 4.0 GHz 11 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 130 W Y Y Y N Y Std
4216 16 / 32 2.1 / 3.2 GHz 22 MB 2400 MHz 1 TB 2, 9.6 GT/s 1 100 W Y Y Y N N Std
Intel Xeon 5200 (Gold) processors
5215 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 85 W Y Y Y N Y Adv
5215M 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 2 TB 2, 10.4 GT/s 1 85 W Y Y Y N Y Adv
5215L 10 / 20 2.5 / 3.4 GHz 13.75 MB 2666 MHz 4.5 TB 2, 10.4 GT/s 1 85 W Y Y Y N Y Adv
5217 8 / 16 3.0 / 3.7 GHz 11 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 115 W Y Y Y N Y Adv
5218** 16 / 32 2.3 / 3.9 GHz 22 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 125 W Y Y Y N Y Adv
5218B** 16 / 32 2.3 / 3.9 GHz 22 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 125 W Y Y Y N Y Adv
5218R 20 / 40 2.1 / 4.0 GHz 27.5 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 125 W Y Y Y N Y Adv
5218T 16 / 32 2.1 / 3.9 GHz 22 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 105 W Y Y Y N Y Adv
5220 18 / 36 2.2 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 125 W Y Y Y N Y Adv
5220S 18 / 36 2.7 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 125 W Y Y Y N Y Adv
5220T 18 / 36 1.9 / 3.9 GHz 24.75 MB 2666 MHz 1 TB 2, 10.4 GT/s 1 105 W Y Y Y N Y Adv
5222 4 / 8 3.8 / 3.9 GHz 16.5 MB* 2933 MHz 1 TB 2, 10.4 GT/s 2 105 W Y Y Y N Y Adv
Intel Xeon 6200 (Gold) processors
6209U 20 / 40 2.1 / 3.9 GHz 27.5 MB 2933 MHz 1 TB None 2 125 W Y Y Y N Y Adv
6222V 20 / 40 1.8 / 3.6 GHz 27.5 MB 2400 MHz 1 TB 3, 10.4 GT/s 2 115 W Y Y Y N Y Adv
6226 12 / 24 2.7 / 3.7 GHz 19.25 MB* 2933 MHz 1 TB 3, 10.4 GT/s 2 125 W Y Y Y N Y Adv
6230 20 / 40 2.1 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 3, 10.4 GT/s 2 125 W Y Y Y N Y Adv
6230T 20 / 40 2.1 / 3.9 GHz 27.5 MB 2933 MHz 1 TB 3, 10.4 GT/s 2 125 W Y Y Y N Y Adv
6238T 22 / 44 1.9 / 3.7 GHz 30.25 MB 2933 MHz 1 TB 3, 10.4 GT/s 2 125 W Y Y Y N Y Adv
Intel Xeon 8200 (Platinum) processors
8253 16 / 32 2.2 / 3.0 GHz 22 MB 2933 MHz 1 TB 3, 10.4 GT/s 2 125 W Y Y Y N Y Adv
8256 4 / 8 3.8 / 3.9 GHz 16.5 MB* 2933 MHz 1 TB 3, 10.4 GT/s 2 105 W Y Y Y N Y Adv

* L3 cache is 1.375 MB per core or larger. Processors with a larger L3 cache per core are marked with an *
** The Intel Xeon Gold 5218 and 5218B processors have similar specifications; however, they use different silicon designs and cannot be mixed in the same system.

Memory options

The ST550 server supports Lenovo TruDDR4 memory. TruDDR4 memory uses the highest-quality components sourced from Tier 1 DRAM suppliers and only memory that meets strict requirements is selected. It is compatibility-tested and tuned to maximize performance and reliability.

TruDDR4 memory has a unique signature programmed into the DIMM, which enables ThinkSystem servers to verify whether the memory installed is qualified and supported. From a service and support standpoint, TruDDR4 memory automatically assumes the system's warranty, and service and support provided worldwide.

The ST550 supports up to 6 DIMMs per processor, for a total of 12 DIMMs when two processors are installed. Each processor has six memory channels, and supports one DIMM per channel.

With second-generation Intel Xeon Scalable processors, the ST550 supports 2666 MHz or 2933 MHz memory. It is supported to have a mix of 2933 MHz and 2666 MHz memory, however all memory will operate at the lower speed. In addition, if the processor selected has a lower memory bus speed (eg 2400 MHz or 2133 MHz - see the Processor options section), then all DIMMs will operate at that lower speed.

The following table lists the memory options that are available for the ST550 server with second-generation Intel Xeon Scalable processors.

Persistent Memory: Intel Optane DC Persistent Memory (DCPMM) is not supported in the ST550.

Table 13. Memory options
Part
number
Feature
code
Description Maximum
supported
2933 MHz RDIMMs
4ZC7A08706 B4H1 ThinkSystem 8GB TruDDR4 2933MHz (1Rx8 1.2V) RDIMM 12 (6 per processor)
4ZC7A08707 B4LY ThinkSystem 16GB TruDDR4 2933 MHz (1Rx4 1.2V) RDIMM 12 (6 per processor)
4ZC7A08708 B4H2 ThinkSystem 16GB TruDDR4 2933MHz (2Rx8 1.2V) RDIMM 12 (6 per processor)
4ZC7A08709 B4H3 ThinkSystem 32GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM 12 (6 per processor)
4ZC7A08710 B4H4 ThinkSystem 64GB TruDDR4 2933MHz (2Rx4 1.2V) RDIMM 12 (6 per processor)
2666 MHz RDIMMs
7X77A01302 AUNB ThinkSystem 16GB TruDDR4 2666 MHz (1Rx4 1.2V) RDIMM 12 (6 per processor)
7X77A01303 AUNC ThinkSystem 16GB TruDDR4 2666 MHz (2Rx8 1.2V) RDIMM 12 (6 per processor)
7X77A01304 AUND ThinkSystem 32GB TruDDR4 2666 MHz (2Rx4 1.2V) RDIMM 12 (6 per processor)

The following rules apply when selecting the memory configuration:

  • The server supports RDIMMs and LRDIMMs.
  • Mixing RDIMMs and LRDIMMs is not supported. Use either RDIMMs or LDRIMMs but not both.
  • Mixing 2666 MHz and 2933 MHz DIMMs is supported. All memory will operate at the lower speed.
  • Mixing x4 and x8 DIMMs is supported.
  • For best performance, populate memory DIMMs in quantities of 6 per processor, so that all memory channels are used.

The following memory protection technologies are supported:

  • ECC
  • SDDC (for x4-based memory DIMMs; look for "x4" in the DIMM description)
  • ADDDC (for x4-based memory DIMMs; Gold and Platinum processors only)
  • Memory channel mirroring
  • Memory rank sparing

If memory channel mirroring is used, then DIMMs must be installed in pairs (minimum of one pair per processor), and both DIMMs in a pair must be identical in type and size. 50% of the installed capacity is available to the operating system.

If memory rank sparing is used, then a minimum of one quad-rank DIMM or two single-rank or dual-rank DIMMs must be installed per populated channel (the DIMMs do not need to be identical). In rank sparing mode, one rank of a DIMM in each populated channel is reserved as spare memory. The largest rank in the channel will be automatically selected as the spare rank. The amount of memory available to the operating system depends on the number, capacity and rank counts of the DIMMs installed.

Internal storage

The ST550 supports 2.5-inch hot-swap, 3.5-inch hot-swap, and 3.5-inch simple-swap drives in a variety of drive bay configurations.

In this section:

Drive bays and backplanes

The server supports up to 20 drive bays: It can support up to 16x 2.5-inch drives or 8x 3.5-inch drives, plus an additional 4x 2.5-inch drive bays installed in the space occupied by the two 5.25-inch media bays. Hot-swap (HS) drive configurations support SAS & SATA drives, and with an AnyBay backplane, can support up to four NVMe drives. Simple-swap (SS) drive configurations support SATA drives only. The server also supports one or two M.2 drives, installed in an M.2 adapter. The dual-M.2 adapter provides RAID 0 and 1 support.

The different drive bay configurations supported are shown in the following figure.

Internal drive bay configurations
Figure 6. Internal drive bay configurations

The following table lists all available drive configurations.

Table 14. Drive configurations
Configuration Backplane 5.25-inch media bays
2.5-inch hot-swap drive bay configurations
8x 2.5-inch SAS/SATA One 8x2.5-inch SAS/SATA Available
8x 2.5-inch SAS/SATA,
4 bays supporting NVMe
One 8x2.5-inch AnyBay Available
16x 2.5-inch SAS/SATA Two 8x2.5-inch SAS/SATA Available
16x 2.5-inch SAS/SATA,
4 bays supporting NVMe
One 8x2.5-inch SAS/SATA +
One 8x2.5-inch AnyBay
Available
20x 2.5-inch SAS/SATA Two 8x2.5-inch SAS/SATA +
4x2.5-inch Media Bay conversion
Converted to
2.5-inch drive bays
20x 2.5-inch SAS/SATA,
4 bays supporting NVMe
One 8x2.5-inch SAS/SATA +
One 8x2.5-inch AnyBay +
4x2.5-inch Media Bay conversion
Converted to
2.5-inch drive bays
3.5-inch and 3.5+2.5-inch hot-swap drive bay hybrid configurations
4x 3.5-inch SAS/SATA One 4x3.5-inch SAS/SATA Available
8x 3.5-inch SAS/SATA One 8x3.5-inch SAS/SATA Available
8x 3.5-inch SAS/SATA +
4x 2.5-inch SAS/SATA
One 8x3.5-inch SAS/SATA +
4x2.5-inch Media Bay conversion
Converted to
2.5-inch drive bays
3.5-inch simple-swap drive bay configurations
4x 3.5-inch SATA One Simple-swap bracket plate Available
8x 3.5-inch SATA Two Simple-swap bracket plates Available

The drive backplanes used with these configurations are listed in the following table.

Table 15. Drive backplanes
Part number Feature Description Purpose
None* AVRN ThinkSystem ST550 2.5" SATA/SAS 8-Bay Backplane 2.5-inch SAS/SATA
None* AUR5 ThinkSystem 2U/Twr 2.5" AnyBay 8-Bay Backplane 2.5-inch AnyBay
None* AVRQ ThinkSystem ST550 4x3.5" Backplane 3.5-inch SAS/SATA
None* AVRM ThinkSystem ST550 2.5" SATA/SAS 4-Bay Backplane Media bay conversion
None* AVRY ThinkSystem ST550 3.5" SATA 4-Bay Simple Swap Backplate Simple-swap drives

* Backplanes are configure-to-order only, however upgrade kits are available that include backplanes, as described in the Field upgrades section below.

Adapters and cabling

This section describes the adapter and cabling requirements for each drive bay configuration.

Notes:

  • For configurations with 16x 2.5-inch drive bays (i.e., two backplanes), you can select either one 16-port SAS/SATA adapter or two 8-port SAS/SATA adapters
  • For configurations with 20x 2.5-inch drive bays, a single 24-port SAS/SATA adapter is used.
  • For the use of AnyBay drive bays, a NVMe Switch adapter is used to provide the NVMe ports. The adapter is installed in slot 2 (which connects to processor 1).

The drive bay configurations are shown in the the subsections below. Where there are different adapter and cabling options, they are shown by the letters A, B, C, D. These configuration numbers are also referenced later in the Field upgrades section.

  1. 8x 2.5-inch hot-swap drive bays, all SAS/SATA
  2. 8x 2.5-inch hot-swap drive bays, where 4 of the bays are AnyBay
  3. 16x 2.5-inch hot-swap drive bays, all SAS/SATA
  4. 16x 2.5-inch hot-swap drive bays, where 4 of the bays are AnyBay
  5. 20x 2.5-inch hot-swap drive bays, all SAS/SATA
  6. 20x 2.5-inch hot-swap drive bays, where 4 of the bays are AnyBay
  7. 4x 3.5-inch drive bays, all SAS/SATA
  8. 8x 3.5-inch hot-swap hot-swap drive bays, all SAS/SATA
  9. 8x 3.5-inch + 4x 2.5-in hot-swap drive bays, all SAS/SATA
  10. 4x 3.5-inch simple-swap drive bays, SATA only
  11. 8x 3.5-inch simple-swap drive bays, SATA only

Tip: The adapters are described in detail in the Controllers for internal storage section.

1. 8x 2.5-inch hot-swap drive bays, all SAS/SATA

In this drive bay configuration, all eight 2.5-inch hot-swap drives are connected to one 8-port SAS/SATA RAID adapter or HBA using two backplane cables, as shown in the following figure.

Adapter and cabling for 8x 2.5-inch drive bays, all SAS/SATA
Figure 7. Adapter and cabling for 8x 2.5-inch drive bays, all SAS/SATA

2. 8x 2.5-inch hot-swap drive bays, where four of the bays are AnyBay

In 8x 2.5-inch drive-bay configurations where four of those bays are AnyBay drive bays, an 8-port SAS/SATA RAID adapter or HBA is needed plus an NVMe Switch Adapter to provide the four needed NVMe ports.

In this configuration you can have either up to eight SAS or SATA drives, or you can have up to four NVMe drives in the four AnyBay drive bays along with four SAS or SATA drives in the other bays.

Adapter and cabling for 8x 2.5-in drive bays, where 4 of the bays are AnyBay
Figure 8. Adapter and cabling for 8x 2.5-inch drive bays, where 4 of the bays are AnyBay

3. 16x 2.5-inch hot-swap drive bays, all SAS/SATA

In 16-bay configurations where all 16 2.5-inch drive bays are SAS/SATA drives, you can use either two 8-port SAS/SATA RAID adapters or HBAs or one 16-port SAS/SATA RAID adapter or HBA. These choices are shown in the following figure.

16x 2.5-in drive bays, all SAS/SATA
Figure 9. Adapter and cabling for 16 drive bays, all SAS/SATA

4. 16x 2.5-inch hot-swap drive bays, where four of the bays are AnyBay

In 16-drive configurations where four of the 2.5-inch bays are AnyBay drive bays, a 16-port SAS/SATA RAID adapter or HBA is needed plus an NVMe Switch Adapter to provide the four needed NVMe ports. The configurations are shown in the following figure.

Adapter and cabling for 16 drive bays, where 4 of the bays are AnyBay
Figure 10. Adapter and cabling for 16 drive bays, where 4 of the bays are AnyBay

5. 20x 2.5-inch hot-swap drive bays, all SAS/SATA

In a 20-drive configuration, where all drives are SAS or SATA, all connectivity is provided by a single 24-port SAS/SATA RAID adapter. The top four drive bays are in place of the two 5.25" media bays. Connectivity is shown in the following figure.

20x 2.5-in drive bays, all SAS/SATA
Figure 11. Adapter and cabling for 20 drive bays, all SAS/SATA

6. 20x 2.5-inch hot-swap drive bays, where four of the bays are AnyBay

In this 20-drive configuration, all drives can be SAS or SATA drives, or four can be NVMe drives. SAS/SATA connectivity is provided by a single 24-port SAS/SATA RAID adapter. NVMe connectivity is provided by the NVMe Switch Adapter. The top four drive bays are in place of the two 5.25" media bays. Connectivity is shown in the following figure.

Adapter and cabling for 20 drive bays, where 4 of the bays are AnyBay
Figure 12. Adapter and cabling for 20 drive bays, where 4 of the bays are AnyBay

7. 4x 3.5-inch hot-swap drive bays, all SAS/SATA

In this drive bay configuration, four 3.5-inch hot-swap drives are connected to one 8-port SAS/SATA RAID adapter or HBA using a single backplane cable, as shown in the following figure.

Adapter and cabling for 4x 3.5-inch drive bays, all SAS/SATA
Figure 13. Adapter and cabling for 4x 3.5-inch drive bays, all SAS/SATA

8. 8x 3.5-inch hot-swap drive bays, all SAS/SATA

In this drive bay configuration, eight 3.5-inch hot-swap drives are connected to one 8-port SAS/SATA RAID adapter or HBA using two backplane cables, as shown in the following figure.

Adapter and cabling for 8x 3.5-inch drive bays, all SAS/SATA
Figure 14. Adapter and cabling for 8x 3.5-inch drive bays, all SAS/SATA

9. 8x 3.5-inch + 4x 2.5-inch hot-swap drive bays, all SAS/SATA

In this combination drive configuration, eight 3.5-in drives and four 2.5-inch drives are supported. The top four drive bays are in place of the two 5.25" media bays. All connectivity can be provided by a single 16-port adapter or two 8-port adapters. Connectivity options are shown in the following figure.

Adapter and cabling for 8x 3.5-in + 4x 2.5-in drive bays, all SAS/SATA
Figure 15. Adapter and cabling for 8x 3.5-inch + 4x 2.5-inch drive bays, all SAS/SATA

10. 4x 3.5-inch simple-swap drive bays, SATA only

In this configuration, the server supports four 3.5-inch simple-swap (SS) drive bays, which support only SATA HDDs and SSDs. The drives connect to a single simple-swap bracket plate, which in turn plugs into a mini-SAS HD connector on the system board.

Adapter and cabling for 4x 3.5-in simple-swap drive bays, SATA only
Figure 16. Adapter and cabling for 4x 3.5-inch simple-swap drive bays; SATA only

11. 8x 3.5-inch simple-swap drive bays, SATA only

In this configuration, the server supports eight 3.5-inch simple-swap drives bays, which support only SATA HDDs and SSDs. The drives connect to two simple-swap bracket plates, which in turn each plug into a mini-SAS HD connector on the system board.

8x 3.5-in simple-swap drive bays, SATA only
Figure 17. Adapter and cabling for 8x 3.5-inch simple-swap drive bays; SATA only

Field upgrades

The following table shows the backplane kits you can use after the initial purchase to upgrade the server to add additional drive bays.

Table 16. Drive backplane upgrades
Part number Feature Description Purpose
7XH7A05906 AVRN ThinkSystem ST550 2.5" SATA/SAS 8-Bay Backplane Add 8x 2.5-inch SAS/SATA
7XH7A05907 AUR5 ThinkSystem ST550 2.5" Anybay 8-Bay Backplane Kit Add 8x 2.5-inch AnyBay
7XH7A05908* AVRM ThinkSystem ST550 2.5" SATA/SAS 4-Bay Backplane
(media bay conversion kit)
Add 4x 2.5-inch to media bay
(replace existing 5.25" bays)
7XH7A05905 AVRQ ThinkSystem ST550 3.5" SATA/SAS 4-Bay Backplane Add 4x 3.5-inch HS SAS/SATA
7XH7A05904 AVRY ThinkSystem ST550 3.5" SATA 4-Bay Simple Swap Backplate Add 4x 3.5-inch simple-swap

* The media bay conversion kit also requires an additional system fan if the server has only one processor. See the Fans and cooling section for details.

Each kit contains the backplane and the necessary cables (including PCIe cables for the AnyBay backplane). The 2.5" SATA/SAS 4-Bay Backplane Kit also includes the necessary 4x 2.5-inch drive-bay cage.

In addition to the backplane kits, you will need a RAID adapter or HBA, and if you are adding an AnyBay backplane, you'll also need an NVMe Switch adapter. The adapters are described in the Controllers for internal storage section.

M.2 drives

The server supports one or two M.2 form-factor SATA drives for use as an operating system boot solution. With two M.2 drives configured, the drives are configured by default as a RAID-1 mirrored pair for redundancy.

The M.2 drives install into an M.2 adapter which in turn is installed in a dedicated slot on the system board. See the internal view of the server in the Components and connectors section for the location of the M.2 slot.

There are two M.2 adapters supported, as listed in the following table.

Table 17. M.2 components
Part
number
Feature
code
Description Maximum
supported
7Y37A01092 AUMU ThinkSystem M.2 Enablement Kit
(contains the Single M.2 Boot Adapter; supports 1 drive)
1
7Y37A01093 AUMV ThinkSystem M.2 with Mirroring Enablement Kit
(contains the Dual M.2 Boot Adapter, supports 1 or 2 drives)
1

Supported drives are listed in the Internal drive options section.

For details about M.2 components, see the ThinkSystem M.2 Drives and M.2 Adapters product guide:
https://lenovopress.com/lp0769-thinksystem-m2-drives-adapters

SED encryption key management with ISKLM

The server supports FIPS 140-2 self-encrypting drives (SEDs) as listed in the Internal drive options section. To effectively manage a large deployment of these drives in Lenovo servers, IBM Security Key Lifecycle Manager (SKLM) offers a centralized key management solution. A Lenovo Feature on Demand (FoD) upgrade is used to enable this SKLM support in the management processor of the server.

The following table lists the part numbers and feature codes for the upgrades.

Table 18. FoD upgrades for SKLM support
Part number Feature code Description
Security Key Lifecycle Manager - FoD (United States, Canada, Asia Pacific, and Japan)
00D9998 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00D9999 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S
Security Key Lifecycle Manager - FoD (Latin America, Europe, Middle East, and Africa)
00FP648 A5U1 SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 1 year S&S
00FP649 AS6C SKLM for System x/ThinkSystem w/SEDs - FoD per Install with 3 year S&S

Controllers for internal storage

The ST550 with hot-swap drives supports internal SAS and SATA drives with the addition of a RAID adapter or HBA. For NVMe support, the server supports the use of an NVMe Switch Adapter installed in a PCIe slot.

For simple-swap drive support, the ST550 uses two onboard 6Gb SATA ports to connect the four or eight simple-swap drives. These ports enable Intel RSTe for RAID functionality.

Virtualization support: The SATA ports can be used with virtualization hypervisors, including VMware ESXi, Linux KVM, Xen, and Microsoft Hyper-V, however support is limited to AHCI (non-RAID) mode. RSTe mode is not supported with virtualization hypervisors.

The following table lists the adapters used for the internal disk storage of the ST550 server.

Table 19. Controllers for internal storage - hot-swap drive support
Part number Feature code Description Number
of ports
Maximum
supported
SAS/SATA HBA
7Y37A01088 AUNL ThinkSystem 430-8i SAS/SATA 12Gb HBA 8 2
7Y37A01089 AUNM ThinkSystem 430-16i SAS/SATA 12Gb HBA 16 1
RAID adapters
7Y37A01082 AUNG ThinkSystem RAID 530-8i PCIe 12Gb Adapter 8 2
7Y37A01083* AUNH* ThinkSystem RAID 730-8i 1GB Cache PCIe 12Gb Adapter 8 2
4Y37A09722 B4RQ ThinkSystem RAID 730-8i 2GB Flash PCIe 12Gb Adapter 8 2
7Y37A01084 AUNJ ThinkSystem RAID 930-8i 2GB Flash PCIe 12Gb Adapter 8 2
7Y37A01085 AUNK ThinkSystem RAID 930-16i 4GB Flash PCIe 12Gb Adapter 16 1
4Y37A09721 B31E ThinkSystem RAID 930-16i 8GB Flash PCIe 12Gb Adapter 16 1
7Y37A01086 AUV1 ThinkSystem RAID 930-24i 4GB Flash PCIe 12Gb Adapter 24 1
NVMe adapter
7Y37A01081 AUV2 ThinkSystem 1610-4P NVMe Switch Adapter 4 1

* Country availability: The RAID 730-8i 1GB Cache adapter is not available in USA and Canada.

The following two tables compare the functions of the storage adapters and the onboard SATA.

Table 20. Comparison of internal storage controllers - RAID controllers
Feature RAID 530-8i RAID 730-8i 1GB* RAID 730-8i 2GB RAID 930-8i RAID 930-16i RAID 930-24i
Adapter type RAID controller RAID controller RAID controller RAID controller RAID controller RAID controller
Part number 7Y37A01082 7Y37A01083 4Y37A09722 7Y37A01084 7Y37A01085
4Y37A09721
7Y37A01086
Form factor PCIe HHHL PCIe low profile PCIe low profile PCIe HHHL PCIe HHHL PCIe HHHL
Controller chip LSI SAS3408 LSI SAS3108 LSI SAS3108 LSI SAS3508 LSI SAS3516 LSI SAS3508 + LSI SAS35x36R
Broadcom equivalent MegaRAID 9440-8i MegaRAID 9361-8i MegaRAID 9361-8i MegaRAID 9460-8i MegaRAID 9460-16i MegaRAID 9460-24i
Host interface PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS 12 Gb SAS
Number of ports 8 8 8 8 16 24
Port connectors 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 2x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643) 6x Mini-SAS HD x4 (SFF-8643)
Drive interface SAS, SATA SAS, SATA SAS, SATA SAS, SATA SAS, SATA SAS, SATA
Drive type HDD, SED, SSD HDD, SSD HDD, SED, SSD HDD, SED, SSD HDD, SED, SSD HDD, SED, SSD
Hot-swap drives Yes Yes Yes Yes Yes Yes
Max devices 8 8 8 8 16 24**
RAID levels 0, 1, 10, 5, 50 0, 1, 10, 5, 50 0, 1, 10, 5, 50, 6, 60 0, 1, 10, 5, 50, 6, 60 0, 1, 10, 5, 50, 6, 60 0, 1, 10, 5, 50, 6, 60
JBOD mode Yes Yes Yes Yes Yes Yes
Cache None 1GB (Standard) 2GB (Standard) 2GB (Standard) 4GB or 8GB (Standard) 4GB (Standard)
CacheVault cache protection No No Yes Yes (Flash) Yes (Flash) Yes (Flash)
Performance Accelerator (FastPath) Yes No Yes Yes Yes Yes
SSD Caching (CacheCade Pro 2.0) No No No No No No
SED support† Yes No Yes Yes Yes Yes

* Country availability: The RAID 730-8i 1GB Cache adapter is not available in USA and Canada.
† SED support by RAID controllers is provided using the built-in MegaRAID SafeStore functionality of the adapter.
** With the ST550, the RAID 930-24i supports up to 20 drives.

Table 21. Comparison of internal storage controllers - HBAs and NVMe Switch Adapter
Feature Intel RSTe 430-8i 430-16i 1610-4P NVMe
Adapter type Software RAID HBA HBA NVMe switch
Part number None 7Y37A01088 7Y37A01089 7Y37A01081
Form factor Onboard PCIe low profile PCIe low profile PCIe HHHL
Controller chip Intel PCH (RSTe) LSI SAS3408 LSI SAS3416 Broadcom PEX9733
Broadcom equivalent Not applicable HBA 9400-8i HBA 9400-16i P310W-4P
Host interface Not applicable PCIe 3.0 x8 PCIe 3.0 x8 PCIe 3.0 x16
Port interface 6 Gb SATA 12 Gb SAS 12 Gb SAS PCIe
Number of ports Varies 8 16 4
Port connectors Onboard 2x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643) 4x Mini-SAS HD x4 (SFF-8643)
Drive interface SATA SAS, SATA SAS, SATA PCIe NVMe
Drive type HDD, SSD HDD, SSD, SED** HDD, SSD, SED** SSD
Hot-swap drives No Yes Yes Yes
Max devices Varies 8 16 4
RAID levels 0, 1, 10, 5 No RAID No RAID No RAID
JBOD mode Yes Yes Yes Yes
Cache None No No None
CacheVault cache protection No No No No
Performance Accelerator (FastPath) No No No No
SSD Caching (CacheCade Pro 2.0) No No No No
SED support No Yes** Yes** No

** SED support of the SAS HBAs is by using software on the server (SED commands are passed through the HBA to the drives).

Internal drive options

The following tables list the hard disk drive and solid-state drive options for the internal disk storage of the server.

Tip: The use of M.2 drives requires an additional adapter as described in the M.2 drives subsection.

Table 22. 2.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 12 Gb SAS 10K
7XB7A00024 AULY ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00025 AULZ ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00026 AUM0 ThinkSystem 2.5" 900GB 10K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00027 AUM1 ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00028 AUM2 ThinkSystem 2.5" 1.8TB 10K SAS 12Gb Hot Swap 512e HDD 20
7XB7A00069 B0YS ThinkSystem 2.5" 2.4TB 10K SAS 12Gb Hot Swap 512e HDD 20
2.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00021 AULV ThinkSystem 2.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00022 AULW ThinkSystem 2.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00023 AULX ThinkSystem 2.5" 900GB 15K SAS 12Gb Hot Swap 512e HDD 20
2.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00034 AUM6 ThinkSystem 2.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD 20
7XB7A00035 AUM7 ThinkSystem 2.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD 20
2.5-inch hot-swap SED HDDs - 12 Gb SAS 10K
7XB7A00030 AUM4 ThinkSystem 2.5" 300GB 10K SAS 12Gb Hot Swap 512n HDD SED 20
7XB7A00031 AUM5 ThinkSystem 2.5" 600GB 10K SAS 12Gb Hot Swap 512n HDD SED 20
7XB7A00033 B0YX ThinkSystem 2.5" 1.2TB 10K SAS 12Gb Hot Swap 512n HDD SED 20
Table 23. 2.5-inch hot-swap 6 Gb SAS/SATA HDDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00036 AUUE ThinkSystem 2.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD 20
7XB7A00037 AUUJ ThinkSystem 2.5" 2TB 7.2K SATA 6Gb Hot Swap 512e HDD 20
Table 24. 2.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 12 Gb SAS - Mainstream (3-5 DWPD)
4XB7A17062 B8HU ThinkSystem 2.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD 20
4XB7A17063 B8J4 ThinkSystem 2.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD 20
4XB7A17064 B8JD ThinkSystem 2.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD 20
4XB7A13653 B4A0 ThinkSystem 2.5" PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD 20
4XB7A13654 B4A1 ThinkSystem 2.5" PM1645 1.6TB Mainstream SAS 12Gb Hot Swap SSD 20
4XB7A13655 B4A2 ThinkSystem 2.5" PM1645 3.2TB Mainstream SAS 12Gb Hot Swap SSD 20
2.5-inch hot-swap SSDs - 12 Gb SAS - Entry / Capacity (<3 DWPD)
4XB7A38175 B91A ThinkSystem 2.5" PM1643a 960GB Entry SAS 12Gb Hot Swap SSD 20
4XB7A38176 B91B ThinkSystem 2.5" PM1643a 1.92TB Entry SAS 12Gb Hot Swap SSD 20
4XB7A17054 B91C ThinkSystem 2.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD 20
4XB7A17055 B91D ThinkSystem 2.5" PM1643a 7.68TB Entry SAS 12Gb Hot Swap SSD 20
4XB7A13646 B4A6 ThinkSystem 2.5" PM1643 7.68TB Capacity SAS 12Gb Hot Swap SSD 20
4XB7A13645 B4A7 ThinkSystem 2.5" PM1643 3.84TB Capacity SAS 12Gb Hot Swap SSD 20
Table 25. 2.5-inch hot-swap 6 Gb SAS/SATA SSDs
Part number Feature Description Maximum
supported
2.5-inch hot-swap SSDs - 6 Gb SATA - Mainstream (3-5 DWPD)
4XB7A17087 B8J1 ThinkSystem 2.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A17088 B8HY ThinkSystem 2.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A17089 B8J6 ThinkSystem 2.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A17090 B8JE ThinkSystem 2.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A17091 B8J7 ThinkSystem 2.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A13633 B49L ThinkSystem 2.5" Intel S4610 240GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A13634 B49M ThinkSystem 2.5" Intel S4610 480GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A13635 B49N ThinkSystem 2.5" Intel S4610 960GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A13636 B49P ThinkSystem 2.5" Intel S4610 1.92TB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A13637 B49Q ThinkSystem 2.5" Intel S4610 3.84TB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A10237 B488 ThinkSystem 2.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A10238 B489 ThinkSystem 2.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A10239 B48A ThinkSystem 2.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A10240 B48B ThinkSystem 2.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD 20
4XB7A10241 B48C ThinkSystem 2.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD 20
7SD7A05761 B110 ThinkSystem 2.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD 20
2.5-inch hot-swap SSDs - 6 Gb SATA - Entry (<3 DWPD)
4XB7A17075 B8HV ThinkSystem 2.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A17076 B8JM ThinkSystem 2.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A17077 B8HP ThinkSystem 2.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A17078 B8J5 ThinkSystem 2.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A17079 B8JP ThinkSystem 2.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A17080 B8J2 ThinkSystem 2.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A38185 B9AC ThinkSystem 2.5" 5210 960GB Entry SATA 6Gb Hot Swap QLC SSD 20
4XB7A38144 B7EW ThinkSystem 2.5" 5210 1.92TB Entry SATA 6Gb Hot Swap QLC SSD 20
4XB7A38145 B7EX ThinkSystem 2.5" 5210 3.84TB Entry SATA 6Gb Hot Swap QLC SSD 20
4XB7A38146 B7EY ThinkSystem 2.5" 5210 7.68TB Entry SATA 6Gb Hot Swap QLC SSD 20
4XB7A10247 B498 ThinkSystem 2.5" Intel S4510 240GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10248 B499 ThinkSystem 2.5" Intel S4510 480GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10249 B49A ThinkSystem 2.5" Intel S4510 960GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A13622 B49B ThinkSystem 2.5" Intel S4510 1.92TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A13623 B49C ThinkSystem 2.5" Intel S4510 3.84TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10195 B34H ThinkSystem 2.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10196 B34J ThinkSystem 2.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10197 B34K ThinkSystem 2.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10198 B34L ThinkSystem 2.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10199 B34M ThinkSystem 2.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10200 B4D2 ThinkSystem 2.5" PM883 7.68TB Entry SATA 6Gb Hot Swap SSD 20
7SD7A05742 B0YY ThinkSystem 2.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD 20
7SD7A05740 B0Z0 ThinkSystem 2.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD 20
7N47A00111 AUUQ ThinkSystem 2.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10153 B2X2 ThinkSystem 2.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10154 B2X3 ThinkSystem 2.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10155 B2X4 ThinkSystem 2.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10156 B2X5 ThinkSystem 2.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A10157 B2X6 ThinkSystem 2.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD 20
4XB7A08505 B10R ThinkSystem 2.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD 20
Table 26. 2.5-inch U.2 NVMe SSDs
Part number Feature Description Maximum
supported
2.5-inch SSDs - NVMe - Entry (<3 DWPD)
4XB7A10202 B58F ThinkSystem U.2 Intel P4510 1.0TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A10204 B58G ThinkSystem U.2 Intel P4510 2.0TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A10205 B58H ThinkSystem U.2 Intel P4510 4.0TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A10175 B34N ThinkSystem U.2 PM983 1.92TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A10176 B34P ThinkSystem U.2 PM983 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
7N47A00985 AUUU ThinkSystem U.2 PM963 3.84TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
4XB7A10177 B4D3 ThinkSystem U.2 PM983 7.68TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4
7SD7A05777 B11E ThinkSystem U.2 Intel P4500 4.0TB Entry NVMe PCIe 3.0 x4 Hot Swap SSD 4

Note: NVMe PCIe SSDs support informed hot removal and hot insertion, provided the operating system supports PCIe SSD hot-swap.

Table 27. 3.5-inch hot-swap 12 Gb SAS HDDs
Part number Feature Description Maximum
supported
3.5-inch hot-swap HDDs - 12 Gb SAS 15K
7XB7A00038 AUU2 ThinkSystem 3.5" 300GB 15K SAS 12Gb Hot Swap 512n HDD 8
7XB7A00039 AUU3 ThinkSystem 3.5" 600GB 15K SAS 12Gb Hot Swap 512n HDD 8
3.5-inch hot-swap HDDs - 12 Gb NL SAS
7XB7A00041 AUU4 ThinkSystem 3.5" 1TB 7.2K SAS 12Gb Hot Swap 512n HDD 8
7XB7A00042 AUU5 ThinkSystem 3.5" 2TB 7.2K SAS 12Gb Hot Swap 512n HDD 8
7XB7A00043 AUU6 ThinkSystem 3.5" 4TB 7.2K SAS 12Gb Hot Swap 512n HDD 8
7XB7A00044 AUU7 ThinkSystem 3.5" 6TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
7XB7A00045 B0YR ThinkSystem 3.5" 8TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
7XB7A00046 AUUG ThinkSystem 3.5" 10TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
7XB7A00067 B117 ThinkSystem 3.5" 12TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
4XB7A13906 B496 ThinkSystem 3.5" 14TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
4XB7A13911 B7EZ ThinkSystem 3.5" 16TB 7.2K SAS 12Gb Hot Swap 512e HDD 8
Table 28. 3.5-inch hot-swap 6 Gb SAS/SATA HDDs
Part number Feature Description Maximum
supported
3.5-inch hot-swap HDDs - 6 Gb NL SATA
7XB7A00049 AUUF ThinkSystem 3.5" 1TB 7.2K SATA 6Gb Hot Swap 512n HDD 8
7XB7A00050 AUUD ThinkSystem 3.5" 2TB 7.2K SATA 6Gb Hot Swap 512n HDD 8
7XB7A00051 AUU8 ThinkSystem 3.5" 4TB 7.2K SATA 6Gb Hot Swap 512n HDD 8
7XB7A00052 AUUA ThinkSystem 3.5" 6TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
7XB7A00053 AUU9 ThinkSystem 3.5" 8TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
7XB7A00054 AUUB ThinkSystem 3.5" 10TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
7XB7A00068 B118 ThinkSystem 3.5" 12TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
4XB7A13907 B497 ThinkSystem 3.5" 14TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
4XB7A13914 B7F0 ThinkSystem 3.5" 16TB 7.2K SATA 6Gb Hot Swap 512e HDD 8
Table 29. 3.5-inch hot-swap 12 Gb SAS SSDs
Part number Feature Description Maximum
supported
3.5-inch hot-swap SSDs - 12 Gb SAS - Mainstream (3-5 DWPD)
4XB7A17066 B8HT ThinkSystem 3.5" PM1645a 800GB Mainstream SAS 12Gb Hot Swap SSD 8
4XB7A17043 B8JN ThinkSystem 3.5" PM1645a 1.6TB Mainstream SAS 12Gb Hot Swap SSD 8
4XB7A17067 B8JK ThinkSystem 3.5" PM1645a 3.2TB Mainstream SAS 12Gb Hot Swap SSD 8
4XB7A13657 B4A3 ThinkSystem 3.5" PM1645 800GB Mainstream SAS 12Gb Hot Swap SSD 8
4XB7A13658 B4A4 ThinkSystem 3.5" PM1645 1.6TB Mainstream SAS 12Gb Hot Swap SSD 8
3.5-inch hot-swap SSDs - 12 Gb SAS - Entry / Capacity (<3 DWPD)
4XB7A17058 B91E ThinkSystem 3.5" PM1643a 3.84TB Entry SAS 12Gb Hot Swap SSD 8
4XB7A13649 B4A8 ThinkSystem 3.5" PM1643 3.84TB Capacity SAS 12Gb Hot Swap SSD 20
Table 30. 3.5-inch hot-swap 6 Gb SAS/SATA SSDs
Part number Feature Description Maximum
supported
3.5-inch hot-swap SSDs - 6 Gb SATA - Mainstream (3-5 DWPD)
4XB7A17096 B8JL ThinkSystem 3.5" 5300 240GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A17097 B8JF ThinkSystem 3.5" 5300 480GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A17098 B8J0 ThinkSystem 3.5" 5300 960GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A17099 B8HR ThinkSystem 3.5" 5300 1.92TB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A17100 B8HX ThinkSystem 3.5" 5300 3.84TB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A13639 B49R ThinkSystem 3.5" Intel S4610 240GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A13640 B49S ThinkSystem 3.5" Intel S4610 480GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A13641 B49T ThinkSystem 3.5" Intel S4610 960GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A13642 B49U ThinkSystem 3.5" Intel S4610 1.92TB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A13643 B49V ThinkSystem 3.5" Intel S4610 3.84TB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A10242 B48D ThinkSystem 3.5" 5200 240GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A10243 B48E ThinkSystem 3.5" 5200 480GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A10244 B48F ThinkSystem 3.5" 5200 960GB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A10245 B48G ThinkSystem 3.5" 5200 1.92TB Mainstream SATA 6Gb Hot Swap SSD 8
4XB7A10246 B48H ThinkSystem 3.5" 5200 3.84TB Mainstream SATA 6Gb Hot Swap SSD 8
7SD7A05756 B115 ThinkSystem 3.5" 5100 3.84TB Mainstream SATA 6Gb Hot Swap SSD 8
3.5-inch hot-swap SSDs - 6 Gb SATA - Entry (<3 DWPD)
4XB7A17081 B8JB ThinkSystem 3.5" 5300 240GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17082 B8J9 ThinkSystem 3.5" 5300 480GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17083 B8JC ThinkSystem 3.5" 5300 960GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17084 B8HZ ThinkSystem 3.5" 5300 1.92TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17085 B8HQ ThinkSystem 3.5" 5300 3.84TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17086 B8J3 ThinkSystem 3.5" 5300 7.68TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A13625 B49D ThinkSystem 3.5" Intel S4510 240GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A13626 B49E ThinkSystem 3.5" Intel S4510 480GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A13627 B49F ThinkSystem 3.5" Intel S4510 960GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A13628 B49G ThinkSystem 3.5" Intel S4510 1.92TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A13629 B49H ThinkSystem 3.5" Intel S4510 3.84TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17176 B6TM ThinkSystem 3.5" PM883 240GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17177 B6TN ThinkSystem 3.5" PM883 480GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17178 B6TP ThinkSystem 3.5" PM883 960GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17179 B6JY ThinkSystem 3.5" PM883 1.92TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A17180 B6JZ ThinkSystem 3.5" PM883 3.84TB Entry SATA 6Gb Hot Swap SSD 8
7N47A00115 AUUS ThinkSystem 3.5" PM863a 240GB Entry SATA 6Gb Hot Swap SSD 8
7SD7A05737 B0Z3 ThinkSystem 3.5" Intel S4500 240GB Entry SATA 6Gb Hot Swap SSD 8
7SD7A05735 B0Z5 ThinkSystem 3.5" Intel S4500 960GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A10158 B2X7 ThinkSystem 3.5" 5200 480GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A10159 B2X8 ThinkSystem 3.5" 5200 960GB Entry SATA 6Gb Hot Swap SSD 8
4XB7A10160 B2X9 ThinkSystem 3.5" 5200 1.92TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A10161 B2XA ThinkSystem 3.5" 5200 3.84TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A10162 B2XB ThinkSystem 3.5" 5200 7.68TB Entry SATA 6Gb Hot Swap SSD 8
4XB7A08509 B10V ThinkSystem 3.5" 5100 3.84TB Entry SATA 6Gb Hot Swap SSD 8
Table 31. 3.5-inch simple-swap 6 Gb SAS/SATA HDDs
Part number Feature Description Maximum
supported
3.5-inch simple-swap HDDs - 6 Gb NL SATA
7XB7A00055 AUZS ThinkSystem 1TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD 8
7XB7A00056 AUZT ThinkSystem 2TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD 8
7XB7A00057 AUZU ThinkSystem 4TB 7.2K 6Gbps SATA 3.5" Simple Swap 512n HDD 8
7XB7A00058 AXC7 ThinkSystem 6TB 7.2K 6Gbps SATA 3.5" Simple Swap 512e HDD 8
7XB7A00059 AXC6 ThinkSystem 8TB 7.2K 6Gbps SATA 3.5" Simple Swap 512e HDD 8
7XB7A00060 AXC8 ThinkSystem 3.5" 10TB 7.2K SATA 6Gb Simple Swap 512e HDD 8
Table 32. M.2 drives
Part number Feature Description Maximum
supported
M.2 SSDs - 6 Gb SATA - Entry (<3 DWPD)
7N47A00129 AUUL ThinkSystem M.2 32GB SATA 6Gbps Non-Hot Swap SSD 2
7N47A00130 AUUV ThinkSystem M.2 128GB SATA 6Gbps Non-Hot Swap SSD 2
4XB7A14049 B5S4 ThinkSystem M.2 5100 240GB SATA 6Gbps Non-Hot Swap SSD 2
7SD7A05703 B11V ThinkSystem M.2 5100 480GB SATA 6Gbps Non-Hot Swap SSD 2
4XB7A17071 B8HS ThinkSystem M.2 5300 240GB SATA 6Gbps Non-Hot Swap SSD 2
4XB7A17073 B919 ThinkSystem M.2 5300 480GB SATA 6Gbps Non-Hot Swap SSD 2

Internal backup units

The server supports the internal backup unit options that are listed in the following table.

Table 33. Internal backup units
Part number Feature code Description Maximum supported
Drives
4T27A10726 B3YK ThinkSystem Internal Half High LTO Gen6 SAS Tape Drive 1
7T27A01503 AVF5 ThinkSystem Internal Half High LTO Gen7 SAS Tape Drive 1
4T27A10727 B4BM ThinkSystem Internal Half High LTO Gen8 SAS Tape Drive 1
7T27A01501 AVF6 ThinkSystem Internal RDX USB 3.0 Dock 1
LTO Media
7TP7A01604 AVF4 ThinkSystem LTO Gen6 2.5TB Tape Not applicable
7TP7A01606 AVF7 ThinkSystem LTO Gen7 6TB Tape Not applicable
4TP7A09619 B4BN ThinkSystem LTO Gen8 12TB Tape Not applicable
RDX Media
7TP7A01601 AVF8 ThinkSystem RDX 500GB Cartridge Not applicable
7TP7A01602 AVF1 ThinkSystem RDX 1TB Cartridge Not applicable
7TP7A01603 AVF0 ThinkSystem RDX 2TB Cartridge Not applicable
7TP7A04318 AXD1 ThinkSystem RDX 4TB Cartridge Not applicable

The RDX drive is attached via the USB 3.0 port on the system board.

The use of an LTO tape drive requires a SAS HBA, either the 430-8i or 430-16i SAS/SATA 12Gb HBA.

For more information about RDX drive and LTO tape drives, see the Backup Units page on the Lenovo Press site: https://lenovopress.com/servers/options/backup

Optical drives

The ST550 supports the optical drive options listed in the following table.

Table 34. Optical drives
Part number Feature code Description Maximum
supported
Internal optical drives
7XA7A01204* AVEZ ThinkSystem Half High SATA DVD-ROM Optical Disk Drive 2
7XA7A01202 AVEY ThinkSystem Half High SATA DVD-RW Optical Disk Drive 2
External optical drives
7XA7A05926 AVV8 ThinkSystem External USB DVD RW Optical Disk Drive 2

* Lenovo offers two different versions of the DVD-ROM drive, however the differences are only cosmetic. The functions and performance are identical.

The internal optical drives in the table can be installed in any open 5.25-inch drive bay.

The Half High SATA DVD-ROM drive supports the following media and speeds for reading:

  • CD-ROM 48X
  • CD-DA (DAE) 48X
  • CD-R 48X
  • CD-RW 40X
  • DVD-ROM (single layer) 16X
  • DVD-ROM (dual layer) 12X
  • DVD-R (4.7 GB) 16X
  • DVD-R DL 8X
  • DVD+R 16X
  • DVD+R DL 8X
  • DVD-RW (4.7 GB) 8X
  • DVD+RW 8X

The Half High SATA DVD-RW drive supports the same media and speeds for reading as HH DVD-ROM. In addition, this drive supports the following media and speeds for writing:

  • CD-R 24X
  • CD-RW 4X
  • High Speed CD-RW 10X
  • Ultra Speed CD-RW 16X
  • DVD-R 8X
  • DVD-R DL 8X
  • DVD+R 8X
  • DVD+R DL 8X
  • DVD-RW 6X
  • DVD+RW 8X

The ThinkSystem External USB DVD RW Optical Disk Drive is based on the Lenovo Slim DVD Burner DB65 drive and has the following specifications:

  • Read:
    • CD-ROM 24X
    • CD-DA (DAE) 24X
    • CD-R 24X
    • CD-RW 24X
    • DVD-ROM (single layer) 8X
    • DVD-ROM (dual layer) 8X
    • DVD-R (4.7 GB) 8X
    • DVD-R DL 8X
    • DVD+R 8X
    • DVD+R DL 8X
    • DVD-RW (4.7 GB) 8X
    • DVD+RW 8X
  • Write:
    • CD-R 10X (CLV), 24X (PCAV)
    • CD-RW 4X
    • High Speed CD-RW 10X
    • Ultra Speed CD-RW 24X
    • DVD-R 8X
    • DVD-R DL 6X
    • DVD+R 8X
    • DVD+R DL 6X
    • DVD-RW 6X
    • DVD+RW 8X

I/O expansion options

The ST550 server supports up to six PCIe 3.0 slots: Four slots (1, 2, 3 and 6) are supported when only one CPU is installed. Slots 4 and 5 require the second processor. The slot lane widths, available power, and supported adapter height and length are as follows:

  • Slot 1: PCIe 3.0 x8 (25W); full-height, half-length
  • Slot 2: PCIe 3.0 x16 (75W); full-height, half-length
  • Slot 3: PCIe 3.0 x16 (75W); full-height, full-length
  • Slot 4: PCIe 3.0 x16 (x8 wired) (25W); full-height, full-length (requires second processor)
  • Slot 5: PCIe 3.0 x16 (75W); full-height, full-length (requires second processor)
  • Slot 6: PCIe 3.0 x8 (x4 wired) (25W); full-height, full-length

Slots 3 and 5 support double-wide GPUs. When double-wide adapters are used slots 4 and 6 cannot be used.

The following figure shows the locations of the PCIe slots.

ThinkSystem ST550 PCIe slots
Figure 18. ThinkSystem ST550 PCIe slots

Above the PCIe slots is a space for a serial port bracket which is used for making an external serial port available at the rear of the server. The following table lists the ordering information.

Table 35. ThinkSystem COM Port Upgrade Kit ordering information
Part
number
Feature
code
Description Maximum
Supported
7Z17A02577 AUSL ThinkSystem COM Port Upgrade Kit 1

Network adapters

The ST550 has two onboard Gigabit Ethernet ports, connected to the integrated Intel Ethernet Connection X722 controller. 

Note: The onboard Gigabit ports do not support 10 Mbps or 100 Mbps Ethernet connections.

The following table lists other supported network adapters. The maximum supported column indicates which slots each adapter is supported in. For slot locations see the I/O expansion options section.

Table 36. Network adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
Gigabit Ethernet
7ZT7A00482 AUZX ThinkSystem Broadcom 5720 1GbE RJ45 2-Port PCIe Ethernet Adapter All slots 6
7ZT7A00484 AUZV ThinkSystem Broadcom 5719 1GbE RJ45 4-Port PCIe Ethernet Adapter All slots 6
7ZT7A00533 AUZZ ThinkSystem I350-F1 PCIe 1Gb 1-Port SFP Ethernet Adapter By Intel All slots 6
7ZT7A00534 AUZY ThinkSystem I350-T2 PCIe 1Gb 2-Port RJ45 Ethernet Adapter By Intel All slots 6
7ZT7A00535 AUZW ThinkSystem I350-T4 PCIe 1Gb 4-Port RJ45 Ethernet Adapter By Intel All slots 6
10 Gb Ethernet
00MM850 ATRY Intel X550-T1 Single Port 10GBase-T Adapter All slots 6
00MM860 ATPX Intel X550-T2 Dual Port 10GBase-T Adapter All slots 6
7ZT7A00496 AUKP ThinkSystem Broadcom 57416 10GBASE-T 2-Port PCIe Ethernet Adapter All slots 6
4XC7A08225 B31G ThinkSystem QLogic QL41134 PCIe 10Gb 4-Port Base-T Ethernet Adapter All slots 6
7ZT7A00537 AUKX ThinkSystem X710-DA2 PCIe 10Gb 2-Port SFP+ Ethernet Adapter All slots 6*
00AG580 AT7T Emulex VFA5.2 2x10 GbE SFP+ Adapter and FCoE/iSCSI SW All slots 6*
00AG570 AT7S Emulex VFA5.2 2x10 GbE SFP+ PCIe Adapter All slots 6*
7ZT7A00493 AUKN ThinkSystem Emulex OCe14104B-NX PCIe 10Gb 4-Port SFP+ Ethernet Adapter All slots 6*
25 Gb Ethernet
01GR250 AUAJ Mellanox ConnectX-4 Lx 10/25GbE SFP28 2-port PCIe Ethernet Adapter All slots 6*
4XC7A08238 B5T0 ThinkSystem Broadcom 57414 10/25GbE SFP28 2-port PCIe Ethernet Adapter All slots 6*
4XC7A08228 B21R ThinkSystem QLogic QL41262 10/25GbE SFP28 2-Port PCIe Ethernet Adapter All slots 6*
7XC7A05523 B0WY ThinkSystem Intel XXV710-DA2 10/25GbE SFP28 2-Port PCIe Ethernet Adapter All slots 6*

* Requires SFP+ transceivers or DAC cables that must be purchased separately.

For more information, including the transceivers and cables that each adapter supports, see the list of Lenovo Press Product Guides in the Ethernet adapters category:
https://lenovopress.com/servers/options/ethernet

SAS adapters for external storage

The following table lists the SAS HBAs and RAID adapters suitable for connectivity to external storage.

Table 37. Supported SAS HBAs and RAID adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
12 Gb SAS HBA
7Y37A01090 AUNR ThinkSystem 430-8e SAS/SATA 12Gb HBA All slots 6
12 Gb RAID Adapter
7Y37A01087 AUNQ ThinkSystem RAID 930-8e 4GB Flash PCIe 12Gb Adapter All slots 4*

* Limited by the number of supercap mounts in the server

The following table summarizes the features of supported adapters.

Table 38. Comparison of features
Feature 430-8e RAID 930-8e
Adapter type HBA External RAID
Part number 7Y37A01090 7Y37A01087
Controller chip LSI SAS3408 LSI SAS3516
Broadcom equivalent HBA 9400-8e MegaRAID 9480-8e
Host interface PCIe 3.0x8 PCIe 3.0x8
Port interface 12 Gb SAS 12 Gb SAS
Number of ports 8 8
Port connectors 2x Mini-SAS HD SFF8644 2x Mini-SAS HD SFF8644
Drive interface SAS/SATA SAS,SATA
Drive type HDD/SSD/SED* HDD,SED,SSD
Hot-swap drives Yes Yes
Maximum devices 1024 216
RAID levels None 0/1/10/5/50/6/60
JBOD mode Yes Yes
Cache None 4GB (Standard)
CacheVault cache protection None Yes (Flash)
Performance Accelerator (FastPath) No Yes
SSD Caching (CacheCade Pro 2.0) No No
SED support* Yes* Yes

* SED (self-encrypting drive) support of the SAS HBA is by using software on the server (SED commands are passed through the HBA to the drives).

Fibre Channel host bus adapters

The following table lists the Fibre Channel HBAs supported by the server.

Table 39. Fibre Channel adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
16 Gb Fibre Channel
01CV840 ATZV Emulex 16Gb Gen6 FC Dual-port HBA All slots 6
01CV830 ATZU Emulex 16Gb Gen6 FC Single-port HBA All slots 6
01CV760 ATZC QLogic 16Gb Enhanced Gen5 FC Dual-port HBA All slots 6
01CV750 ATZB QLogic 16Gb Enhanced Gen5 FC Single-port HBA All slots 6

For more information, see the list of Lenovo Press Product Guides in the Host bus adapters category:
https://lenovopress.com/servers/options/hba

Flash Storage adapters

The server currently does not support Flash Storage adapters.

GPU adapters

The ST550 server supports the graphics processing units (GPUs) listed in the following table. Up to two GPUs are supported when two processors are installed in a server (or one GPU with only one processor).

Table 40. GPU adapters
Part
number
Feature
code
Description Slots
supported
Maximum
supported
4X67A11584 B31D ThinkSystem NVIDIA Quadro P620 2GB PCIe Active GPU 3, 5 2
7C57A02877 AUW6 ThinkSystem NVIDIA Quadro P2000 5GB PCIe Active GPU 3, 5 2
4X67A14935 B7JW ThinkSystem NVIDIA Quadro P2200 5GB PCIe Active GPU 3, 5 2
4V17A10255 B225 ThinkSystem NVIDIA Quadro P4000 3, 5† 2
4X67A14934 B6CG ThinkSystem NVIDIA Quadro RTX 4000 8GB PCIe Active GP 3, 5† 2
7C57A02895 AVRK ThinkSystem NVIDIA Quadro P6000 24GB PCIe Active GPU 3, 5* 2

† The use of the P4000 or RTX 4000 requires that ST550 chassis AVS5 (3.5-inch bays) or AVS6 (2.5-inch bays) be selected. See the P4000 topic below.
* The P6000 is a double-width adapter: When installed in slot 3, slot 4 is no longer available. When installed in slot 5, slot 6 is no longer available.

The following other rules apply:

  • If two GPUs are installed, they must be identical
  • The first GPU is installed in slot 3; the second GPU is installed in slot 5 and requires the second processor to be installed.
  • The number of GPUs that can be installed depends on the type of power supply that is installed and the drive bay configuration selected. For more information, see the Power Supplies section.
  • Cooling requirements and limitations in fan redundancy exist for some configurations as described in the Fans and cooling section
  • The use of a GPU requires that Fan 4 (rear fan) be installed.
  • The P4000 GPU can only be installed as a field-upgrade in ST550 servers with chassis B32J (3.5-inch) or B32J (2.5-inch). Older ST550 chassis do not support the P4000 GPU. See the ST550 Setup Guide for information on how to determine which chassis you have.

Tip: NVIDIA Pxxxx GPUs do not have the 1TB system memory limit that previous NVIDIA adapters had.

Chassis selection for NVIDIA Quadro P4000 and RTX 4000

The NVIDIA Quadro P4000 and RTX 4000 use the NVIDIA Form Factor 3.0. in the ST550, to use either of these GPUs, specific chassis feature codes must be selected when building a configure-to-order configuration.

Table 41. Chassis support for GPUs
Feature code Description GPU support
B32K ThinkSystem ST550 16x2.5" CHAS NV3.0 Supports all GPUs
B32J ThinkSystem ST550 8x3.5" CHAS NV3.0 Supports all GPUs
AVS6 ThinkSystem ST550 16x2.5" Chassis Does not support the NVIDIA Quadro P4000 or RTX 4000
AVS5 ThinkSystem ST550 8x3.5" Chassis Does not support the NVIDIA Quadro P4000 or RTX 4000

Configuration notes:

  • There are no other support differences between the two 16x2.5" chasiss (B32K and AVS6) and the two 8x3.5" chassis (B32J and AVS5) other than the mechanical changes needed to support NVIDIA Form Factor 3.0 GPUs like the Quadro P4000 and RTX 4000.
  • There is no field upgrade available to add support for the P4000 in the AVS6 and AVS5 chassis features. If you require P4000 or RTX 4000 support now or in the future, ensure that either the B32K or B32J chassis is selected.

Fans and cooling

The server can operate in environments up to ASHRAE A4 (45°C and 90% humidity). Details and restrictions are described in the Physical and electrical specifications section.

The server supports up to four simple-swap fans, three in the front of the server, just behind the drive bays and one installed at the rear of the server. See the Inside view in the Components and connectors section for locations.

Use of these fans is as follows:

  • Single processor systems require 2 fans, installed in the area behind drive bays
  • The third fan installed behind the drive bays is required in the following situations:
    • The server has two processors. If the second processor is a field upgrade, then the fan is included with the second processor and does not need to be ordered separately.
    • The server has four 2.5-inch hot-swap drives bays installed in place of the two 5.25-inch media bays converted. If the media bay conversion is a field upgrade (part number 7XH7A05908) and the server only has one processor installed, then order the fan using part number 7XH7A06781.
  • Fan 4 (the fan at the rear of the server) can be installed as an N+1 redundant fan if desired. The part number is 7XH7A05900.
  • If a GPU is installed, Fan 4 is required and is non-redundant in most configurations. The following table indicates the cooling restrictions that apply when supported GPUs are installed:
    • Whether or not Fan 4 is redundant
    • Limits to ambient temperatures
Table 42. Cooling restrictions with GPUs installed
GPU configuration NVIDIA P600 selected NVIDIA P2000 selected NVIDIA P6000 selected
One GPU installed Fan 4 is redundant
System is limited to ASHRAE A2 (35°C)
Fan 4 is redundant
System is limited to ASHRAE A2 (35°C)
Fan 4 is non-redundant
System is limited to ASHRAE A2 (35°C)
Two GPUs installed Fan 4 is redundant
System is limited to ASHRAE A2 (35°C)
Fan 4 is non-redundant
System is limited to ASHRAE A2 (35°C)
Fan 4 is non-redundant
System is limited to 30°C ambient

The table below lists the fan upgrades.

Table 43. Fan upgrades
Part number Feature code Description
7XH7A06781 AVS3 ThinkSystem ST550 Front Mid Fan Module for 4x2.5" ODD conversion
7XH7A05900 AVS4 ThinkSystem ST550 Rear Fan Module

Power supplies

The server supports either a single fixed power supply or one or two hot-swap power supplies. When two hot-swap power supplies are installed, they form a redundant pair. The following table lists the supported power supplies.

Table 44. Power supply options
Part number Feature
code
Description Maximum
supported
110V AC 220V AC 240V DC
China only
None* AVS1 450W (230V/115V) Gold AC Fixed (Cabled) Power Supply 1 Yes Yes No
7N67A00882 AWFT 550W (230V/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes
7N67A00883 AWFS 750W (230/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes
7N67A00884 AWFR 750W (230V) Titanium Hot-Swap Power Supply 2 No Yes Yes
7N67A00885 AWFQ 1100W (230V/115V) Platinum Hot-Swap Power Supply 2 Yes Yes Yes

* Configure-to-order only

550W, 750W and 1100W Platinum power supplies are auto-sensing and support both 110V AC (100-127V 50/60 Hz) and 220V AC (200-240V 50/60 Hz) power. The 750W Titanium power supply only supports 220V AC power. In China only, all four hot-swap power supplies also support 240V DC.

Power supply options do not include a line cord.

For server configurations, the inclusion of a power supply is model dependent. Configure-to-order models can be configured without a power cord if desired.

Power supply configuration rules

The following table shows the power supplies supported with and without GPUs and with the various supported drive bay configurations.

For further power configuration of the server, use the Lenovo Capacity Planner, available at:
https://datacentersupport.lenovo.com/us/en/products/solutions-and-software/software/lenovo-capacity-planner/solutions/ht504651

Additional rules:

  • 550W, 750W, 1100W power supplies can be used all processors supported by the server
  • 450W power supply can only be used with processors that have a TDP of 85W or lower
  • 1100W power supply supports GPUs, however limitations on cooling fan redundancy exist for some configurations as described in the Fans and cooling section
Table 45. Power supply support for drive and GPU configurations
Power
supply
4x 3.5 SS 8x 3.5 HS 8x 2.5 HS 16x 2.5 HS 8x 2.5 HS
AnyBay
8x 3.5 +
4x 2.5 HS
16x 2.5 HS
AnyBay
20x 2.5 HS
AnyBay
20x 2.5 HS
Without any GPUs
450W Y* Y* Y* N N N N N N
550W Y Y Y N N N N N N
750W Y Y Y Y Y Y Y Y Y
1100W Y Y Y Y Y Y Y Y Y
With 1 or 2 GPUs**
450W N N N N N N N N N
550W N N N N N N N N N
750W N N N N N N N N N
1100W Y Y Y Y Y Y Y Y Y

* Only with processors that have a TDP of 85W or lower
** See the Fans and cooling section for cooling restrictions with GPUs

Power cords

Line cords and rack power cables can be ordered as listed in the following table.

110V customers: If you plan to use the ThinkSystem 1100W power supply with a 110V power source, select a power cable that is rated above 10A. Power cables that are rated at 10A or below are not supported with 110V power.

Table 46. Power cords
Part number Feature code Description
Rack cables
00Y3043 A4VP 1.0m, 10A/100-250V, C13 to C14 Jumper Cord
39Y7937 6201 1.5m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08369 6570 2.0m, 13A/100-250V, C13 to C14 Jumper Cord
4L67A08366 6311 2.8m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08370 6400 2.8m, 13A/100-250V, C13 to C14 Jumper Cord
39Y7932 6263 4.3m, 10A/100-250V, C13 to C14 Jumper Cord
4L67A08371 6583 4.3m, 13A/100-250V, C13 to C14 Jumper Cord
Line cords
39Y7930 6222 2.8m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
81Y2384 6492 4.3m, 10A/250V, C13 to IRAM 2073 (Argentina) Line Cord
39Y7924 6211 2.8m, 10A/250V, C13 to AS/NZS 3112 (Australia/NZ) Line Cord
81Y2383 6574 4.3m, 10A/250V, C13 to AS/NZS 3112 (Australia/NZ) Line Cord
69Y1988 6532 2.8m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
81Y2387 6404 4.3m, 10A/250V, C13 to NBR 14136 (Brazil) Line Cord
39Y7928 6210 2.8m, 10A/220V, C13 to GB 2099.1 (China) Line Cord
81Y2378 6580 4.3m, 10A/250V, C13 to GB 2099.1 (China) Line Cord
39Y7918 6213 2.8m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
81Y2382 6575 4.3m, 10A/250V, C13 to DK2-5a (Denmark) Line Cord
39Y7917 6212 2.8m, 10A/250V, C13 to CEE 7/7 (Europe) Line Cord
81Y2376 6572 4.3m, 10A/250V, C13 to CEE 7/7 (Europe) Line Cord
39Y7927 6269 2.8m, 10A/250V, C13 to IS 6538 (India) Line Cord
81Y2386 6567 4.3m, 10A/250V, C13 to IS 6538 (India) Line Cord
39Y7920 6218 2.8m, 10A/250V, C13 to SI 32 (Israel) Line Cord
81Y2381 6579 4.3m, 10A/250V, C13 to SI 32 (Israel) Line Cord
39Y7921 6217 2.8m, 10A/250V, C13 to CEI 23-16 (Italy) Line Cord
81Y2380 6493 4.3m, 10A/250V, C13 to CEI 23-16 (Italy) Line Cord
4L67A08362 6495 4.3m, 12A/200V, C13 to JIS C-8303 (Japan) Line Cord
39Y7922 6214 2.8m, 10A/250V, C13 to SABS 164-1 (South Africa) Line Cord
81Y2379 6576 4.3m, 10A/250V, C13 to SANS 164-1 (South Africa) Line Cord
39Y7926 6335 4.3m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord
39Y7925 6219 2.8m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord
81Y2385 6494 4.3m, 12A/250V, C13 to KSC 8305 (S. Korea) Line Cord
39Y7919 6216 2.8m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
81Y2390 6578 4.3m, 10A/250V, C13 to SEV 1011-S24507 (Swiss) Line Cord
23R7158 6386 2.8m, 10A/125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2375 6317 2.8m, 10A/250V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2374 6402 2.8m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
4L67A08363 AX8B 4.3m, 10A/125V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2389 6531 4.3m, 10A/250V, C13 to CNS 10917 (Taiwan) Line Cord
81Y2388 6530 4.3m, 13A/125V, C13 to CNS 10917 (Taiwan) Line Cord
39Y7923 6215 2.8m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
81Y2377 6577 4.3m, 10A/250V, C13 to BS 1363/A (UK) Line Cord
90Y3016 6313 2.8M, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
46M2592 A1RF 2.8m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
00WH545 6401 2.8M, 13A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08359 6370 4.3m, 10A/125V, C13 to NEMA 5-15P (US) Line Cord
4L67A08361 6373 4.3m, 10A/250V, C13 to NEMA 6-15P (US) Line Cord
4L67A08360 AX8A 4.3m, 13A/125V, C13 to NEMA 5-15P (US) Line Cord

The ST550 also supports the following two-up cables.

Table 47. Power cables for ST550
Part number Feature code Description
47C2491 A3SW 1.2m, 10A/100-250V, (2X) C13 to C20 Jumper Cord
47C2492 A3SX 2.5m, 10A/100-250V, (2X) C13 to C20 Jumper Cord
47C2493 A3SY 2.8m, 10A/100-250V, (2X) C13 to C20 Jumper Cord
47C2494 A3SZ 4.1m, 10A/100-250V, (2X) C13 to C20 Jumper Cord

Integrated virtualization

The server supports booting from an operating system or hypervisor installed on an M.2 solid-state drive. See the M.2 drives section for details and the list of available options.

You can download supported VMware vSphere hypervisor images from the following web page and load it on the M.2 drive using the instructions provided:
https://vmware.lenovo.com/content/custom_iso/

Systems management

The server contains an integrated service processor, XClarity Controller (XCC), which provides advanced service-processor control, monitoring, and alerting functions. The XCC is based on the Pilot4 XE401 baseboard management controller (BMC) using a dual-core ARM Cortex A9 service processor.

Local management

The ST550 offers a front operator panel showing key LED status indicators, as shown in the following figure.

ST550 front operator panel
Figure 19. Front operator panel

When you press the ID button on the front panel, the blue system ID LEDs on both the front and rear of the server are lit to help you locate the server among other servers. You also can turn on the system ID LEDs using a remote management program for server presence detection.

System status with XClarity Mobile

The XClarity Mobile app includes a tethering function where you can connect your Android or iOS device to the server via USB to see the status of the server.

The steps to connect the mobile device are as follows:

  1. Enable USB Management on the server, by holding down the ID button for 3 seconds (or pressing the dedicated USB management button if one is present)
  2. Connect the mobile device via a USB cable to the server's USB port with the management symbol USB Management symbol
  3. In iOS or Android settings, enable Personal Hotspot or USB Tethering
  4. Launch the Lenovo XClarity Mobile app

Once connected you can see the following information:

  • Server status including error logs (read only, no login required)
  • Server management functions (XClarity login credentials required)

Remote management

The server offers a dedicated RJ45 port at the rear of the server for remote management via the XClarity Controller management processor. The port supports 10/100/1000 Mbps speeds.

Remote server management is provided through industry-standard interfaces:

  • Intelligent Platform Management Interface (IPMI) Version 2.0
  • Simple Network Management Protocol (SNMP) Version 3 (no SET commands; no SNMP v1)
  • Common Information Model (CIM-XML)
  • Representational State Transfer (REST) support
  • Redfish support (DMTF compliant)
  • Web browser - HTML 5-based browser interface (Java and ActiveX not required) using a responsive design (content optimized for device being used - laptop, tablet, phone) with NLS support

IPMI via the Ethernet port (IPMI over LAN) is supported, however it is disabled by default. For CTO orders you can specify whether you want to the feature enabled or disabled in the factory, using the feature codes listed in the following table.

Table 48. IPMI-over-LAN settings
Part number Feature code Description
CTO only B7XZ Disable IPMI-over-LAN (default)
CTO only B7Y0 Enable IPMI-over-LAN

There are two XClarity Controller upgrades available for the server, Advanced and Enterprise.

Lenovo XClarity Controller Advanced adds the following remote control functions:

  • Remotely viewing video with graphics resolutions up to 1600x1200 at 75 Hz with up to 23 bits per pixel, regardless of the system state
  • Remotely accessing the server using the keyboard and mouse from a remote client
  • Capturing blue-screen errors
  • International keyboard mapping support
  • LDAP-based authentication

Lenovo XClarity Controller Enterprise enables the following additional features:

  • Boot Capture
  • Remote mounting of CD-ROM (ISO) and diskette (IMG) files as virtual drives
  • Virtual console collaboration - Ability for up to 6 remote users to be log into the remote session simultaneously
  • Power capping
  • License for XClarity Energy Manager

Preconfigured models come with either XClarity Controller Standard, Advanced or Enterprise, depending on the model. See the Models section for details. The following table shows the field upgrades available for preconfigured models.

Table 49. XClarity Controller field upgrades
Part number Feature code Description
4L47A09132 AVUT ThinkSystem XClarity Controller Standard to Advanced Upgrade
(for servers that have XCC Standard)
4L47A09133 AVUU ThinkSystem XClarity Controller Advanced to Enterprise Upgrade
(for servers that have XCC Advanced)

For configure-to-order (CTO) models, you can elect to have one of the following XCC functionality by selecting the appropriate XCC feature codes as listed in the following table:

  • XCC Standard - select neither feature listed in the table
  • XCC Advanced - select feature AVUT
  • XCC Enterprise - select feature AUPW
Table 50. XClarity Controller Upgrades for configure-to-order
Feature code Description
AVUT ThinkSystem XClarity Controller Standard to Advanced Upgrade
AUPW ThinkSystem XClarity Controller Standard to Enterprise Upgrade

Lenovo XClarity Provisioning Manager

Lenovo XClarity Provisioning Manager (LXPM) is a UEFI-based application embedded in ThinkSystem servers and accessible via the F1 key during system boot.

LXPM provides the following functions:

  • Graphical UEFI Setup
  • System inventory information and VPD update
  • System firmware updates (UEFI and XCC)
  • RAID setup wizard
  • OS installation wizard (including unattended OS installation)
  • Diagnostics functions

Lenovo XClarity Administrator

Lenovo XClarity Administrator is a centralized resource management solution designed to reduce complexity, speed response, and enhance the availability of Lenovo systems and solutions.

Lenovo XClarity Administrator provides agent-free hardware management for ThinkSystem servers, in addition to ThinkServer, System x, and Flex System servers. The administration dashboard is based on HTML 5 and allows fast location of resources so tasks can be run quickly.

Because Lenovo XClarity Administrator does not require any agent software to be installed on the managed endpoints, there are no CPU cycles spent on agent execution, and no memory is used, which means that up to 1GB of RAM and 1 - 2% CPU usage is saved, compared to a typical managed system where an agent is required.

Lenovo XClarity Administrator provides full management function to ThinkSystem servers, including the following:

  • Discovery
  • Inventory
  • Monitoring and alerting
  • Call home
  • Centralized user management
  • Cryptography modes, server certificates, and encapsulation
  • Configuration patterns
  • Operating system deployment
  • Firmware updates

For more information about Lenovo XClarity Administrator, including ordering part numbers, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Integrators

Lenovo also offers software plug-in modules, Lenovo XClarity Integrators, to manage physical infrastructure from leading external virtualization management software tools including those from Microsoft and VMware.

These integrators are offered at no charge, however if software support is required, a Lenovo XClarity Pro software subscription license should be ordered.

Lenovo XClarity Integrators offer the following additional features:

  • Ability to discover, manage, and monitor Lenovo server hardware from VMware vCenter or Microsoft System Center
  • Deployment of firmware updates and configuration patterns to Lenovo x86 rack servers and Flex System from the virtualization management tool
  • Non-disruptive server maintenance in clustered environments that reduces workload downtime by dynamically migrating workloads from affected hosts during rolling server updates or reboots
  • Greater service level uptime and assurance in clustered environments during unplanned hardware events by dynamically triggering workload migration from impacted hosts when impending hardware failures are predicted

For more information about all the available Lenovo XClarity Integrators, see the Lenovo XClarity Administrator Product Guide: https://lenovopress.com/tips1200-lenovo-xclarity-administrator

Lenovo XClarity Essentials

Lenovo offers the following XClarity Essentials software tools that can help you set up, use, and maintain the server at no additional cost:

  • Lenovo Essentials OneCLI

    OneCLI is a collection of server management tools that uses a command line interface program to manage firmware, hardware, and operating systems. It provides functions to collect full system health information (including health status), configure system settings, and update system firmware and drivers.

  • Lenovo Essentials UpdateXpress

    The UpdateXpress tool is a standalone GUI application for firmware and device driver updates that enables you to maintain your server firmware and device drivers up-to-date and help you avoid unnecessary server outages. The tool acquires and deploys individual updates and UpdateXpress System Packs (UXSPs) which are integration-tested bundles.

  • Lenovo Essentials Bootable Media Creator

    The Bootable Media Creator (BOMC) tool is used to create bootable media for offline firmware update.

For more information and downloads, visit the Lenovo XClarity Essentials web page:
http://support.lenovo.com/us/en/documents/LNVO-center

Lenovo XClarity Energy Manager

Lenovo XClarity Energy Manager is an agent-free, web-based console that provides power management for ThinkSystem servers as well as System x and ThinkServer systems. It enables server density and data center capacity to be increased through the use of power capping.

Lenovo XClarity Energy Manager is a licensed product. A single-node XClarity Energy Manager license is included with the XClarity Controller Enterprise (XCC Enterprise) upgrade as described in the Remote Management section. If your server does not have the XCC Enterprise upgrade, Energy Manager licenses can be ordered as shown in the following table.

Table 51. Lenovo XClarity Energy Manager
Description Part number
4L40E51621 Lenovo XClarity Energy Manager Node License (1 license needed per server)

Security

The server offers the following security features:

  • Electronic security measures:
    • Administrator and power-on passwords
    • Trusted Platform Module (TPM) supporting both TPM 1.2 and TPM 2.0
    • Optional Trusted Cryptographic Module (TCM), available only in China
    • Self-encrypting drives with support for IBM Security Key Lifecycle Manager
  • Mechanical security measures
    • Lockable side cover to help prevent access to internal components
    • Slot at the rear of the server for a Kensington Cable Lock
    • Optional chassis intrusion switch
    • Optional lockable front security door

The TCM module and Nationz TPM module are available only for China customers and are installed in a dedicated socket on the system board, as shown in Figure 4.

The optional lockable front door includes a key that enables you to secure access to the drive bays and system controls, thereby reducing the possibility of unauthorized or accidental access to the server.

The following table lists the security options for the server.

Table 52. Security features
Part number Feature code Description
7XH7A05903 AVRR ThinkSystem ST550 Security Door
None* AVKE ThinkSystem Trusted Cryptographic Module (China customers only)
None* B22N ThinkSystem Nationz Trusted Platform Module v2.0 (China customers only)
None* AVSD ThinkSystem ST550 Intrusion Switch and Cable

* Available via configure-to-order or in preconfigured models only

For SED drives and IBM Security Key Lifecycle Manager support see the SED encryption key management with ISKLM section.

Keyboards and Mice

The following table lists the supported full-sized USB keyboards and mice available for Lenovo ThinkSystem servers.

The keyboards have the following features:

  • Full-sized 104-key keyboard with 3 special Windows keys
  • 3 LEDs for caps lock, scroll lock and num lock
  • Wired USB connection with 1.8m cable
  • Adjustable feet at the rear of the keyboard

Tip: For keyboards that fit in the rack-mounted console kit, see the KVM console options section, or the 1U 18.5-inch Standard Media Console product guide.

Table 53. Lenovo Preferred Pro USB Full-sized keyboards - ThinkSystem
Part number Feature code Description
Mice
7M57A04698 B0LN ThinkSystem Optical Wheel Mouse - USB
Keyboards
7ZB7A05521 AXTM ThinkSystem Pref. Pro Keyboard USB - Arabic 253 RoHS v2
7ZB7A05520 AXTN ThinkSystem Pref. Pro Keyboard USB - Arabic French 462 RoHS v2
7ZB7A05519 AXTP ThinkSystem Pref. Pro Keyboard USB - Belgium/French 120 RoHS v2
7ZB7A05518 AXTQ ThinkSystem Pref. Pro Keyboard USB - Belgium/UK 120 RoHS v2
7ZB7A05517 AXTR ThinkSystem Pref. Pro Keyboard USB - Brazil/Portuguese 275 RoHS v2
7ZB7A05515 AXTS ThinkSystem Pref. Pro Keyboard USB - Bulgarian 442 RoHS v2
7ZB7A05511 AXTU ThinkSystem Pref. Pro Keyboard USB - Czech RoHS v2
7ZB7A05509 AXTV ThinkSystem Pref. Pro Keyboard USB - Danish 159 RoHS v2
7ZB7A05508 AXTW ThinkSystem Pref. Pro Keyboard USB - Dutch 143 RoHS v2
7ZB7A05506 AXTX ThinkSystem Pref. Pro Keyboard USB - French 189 roHS v2
7ZB7A05496 AXTZ ThinkSystem Pref. Pro Keyboard USB - French Canadian 058 French RoHS v2
7ZB7A05504 AXTY ThinkSystem Pref. Pro Keyboard USB - French Canadian 445 Multilingual RoHS v2
7ZB7A05495 AXU0 ThinkSystem Pref. Pro Keyboard USB - German 129 RoHS v2
7ZB7A05494 AXU1 ThinkSystem Pref. Pro Keyboard USB - Greek 319 RoHS v2
7ZB7A05493 AXU2 ThinkSystem Pref. Pro Keyboard USB - Hebrew RoHS v2
7ZB7A05492 AXU3 ThinkSystem Pref. Pro Keyboard USB - Hungarian 208 RoHS v2
7ZB7A05491 AXU4 ThinkSystem Pref. Pro Keyboard USB - Iceland 197 RoHS v2
7ZB7A05490 AXU5 ThinkSystem Pref. Pro Keyboard USB - Italy 141 RoHS v2
7ZB7A05489 AXU6 ThinkSystem Pref. Pro Keyboard USB - Japanese 194 RoHS
7ZB7A05488 AXU7 ThinkSystem Pref. Pro Keyboard USB - Korean 413 RoHS v2
7ZB7A05487 AXU8 ThinkSystem Pref. Pro Keyboard USB - LA Spanish 171 RoHS v2
7ZB7A05486 AXU9 ThinkSystem Pref. Pro Keyboard USB - Norwegian 155 RoHS v2
7ZB7A05485 AXUA ThinkSystem Pref. Pro Keyboard USB - Polish RoHS v2
7ZB7A05484 AXUB ThinkSystem Pref. Pro Keyboard USB - Portuguese 163 RoHS v2
7ZB7A05483 AXUC ThinkSystem Pref. Pro Keyboard USB - Romanian RoHS v2
7ZB7A05482 AXUD ThinkSystem Pref. Pro Keyboard USB - Russian/Cyrillic 441 RoHS v2
7ZB7A05481 AXUE ThinkSystem Pref. Pro Keyboard USB - Serbian/Cyrillic RoHS v2
7ZB7A05480 AXUF ThinkSystem Pref. Pro Keyboard USB - Slovak 245 RoHS v2
7ZB7A05471 AXUQ ThinkSystem Pref. Pro Keyboard USB - Slovenian 234 RoHS v2
7ZB7A05479 AXUG ThinkSystem Pref. Pro Keyboard USB - Spanish 172 RoHS v2
7ZB7A05478 AXUH ThinkSystem Pref. Pro Keyboard USB - Swedish/Finn 153 RoHS v2
7ZB7A05477 AXUJ ThinkSystem Pref. Pro Keyboard USB - Swiss F/G 150 RoHS v2
7ZB7A05476 AXUK ThinkSystem Pref. Pro Keyboard USB - Thailand 191 RoHS v2
7ZB7A05513 AXTT ThinkSystem Pref. Pro Keyboard USB - Trad Chinese/US 467 RoHS v2
7ZB7A05474 AXUM ThinkSystem Pref. Pro Keyboard USB - Turkish 179 RoHS v2
7ZB7A05475 AXUL ThinkSystem Pref. Pro Keyboard USB - Turkish 440 RoHS v2
7ZB7A05473 AXUN ThinkSystem Pref. Pro Keyboard USB - UK English 166 RoHS v2
7ZB7A05522 AXTL ThinkSystem Pref. Pro Keyboard USB - US English 103P RoHS v2
7ZB7A05472 AXUP ThinkSystem Pref. Pro Keyboard USB - US Euro 103P RoHS v2

Rack installation

The server can be installed in the rack with the Tower to Rack Conversion Kit. The resulting server is a 4U rack-mountable server, as shown in the following figure.

ThinkSystem ST550 Rack Conversion
Figure 20. ThinkSystem ST550 with Rack Conversion Kit installed

The part numbers are summarized in the following table.

Table 54. Rack installation options
Part
number
Feature
code
Description
7XH7A05901 AVRZ ThinkSystem ST550 4U Tower to Rack Conversion Kit
7XH7A05902 AVRX ThinkSystem ST550 CMA Kit

The rail kit has the specifications listed in the following table.

Table 55. Rail kit specifications
Feature ThinkSystem ST550 4U Tower to Rack Conversion Kit
Part number 7XH7A05901
Rail type Full-out slide rail (ball bearing)
Toolless installation Yes
Cable Management Arm (CMA) support Optional (7XH7A05902)
In-rack server maintenance Yes
1U PDU support Yes
0U PDU support Limited*
Rack type Lenovo and IBM 4-post, IEC standard-compliant
Mounting holes Square or round
Mounting flange thickness 2 mm - 3.3 mm (0.08 - 0.13 in.)
Distance between front and rear mounting flanges 537 mm - 810 mm (21.1 - 31.9 in.)
Rail length*** 792 mm (31.2 in.)

 * For 0U PDU support, the rack must be at least 1100 mm (43.31 in.) deep without a CMA, or at least 1200 mm (47.24 in.) deep if a CMA is used.
*** Measured when mounted on the rack, from the front surface of the front mounting flange to the rearmost point of the rail.

Supported rack cabinets are listed in the Rack cabinets section.

Operating system support

The ST550 with second-generation Intel Xeon Scalable processors supports the following operating systems:

  • Microsoft Windows Server 2016
  • Microsoft Windows Server 2019
  • Red Hat Enterprise Linux 7.6
  • Red Hat Enterprise Linux 7.7
  • Red Hat Enterprise Linux 7.8
  • Red Hat Enterprise Linux 8.0
  • Red Hat Enterprise Linux 8.1
  • SUSE Linux Enterprise Server 12 SP4
  • SUSE Linux Enterprise Server 12 SP5
  • SUSE Linux Enterprise Server 12 Xen SP4
  • SUSE Linux Enterprise Server 12 Xen SP5
  • SUSE Linux Enterprise Server 15
  • SUSE Linux Enterprise Server 15 SP1
  • SUSE Linux Enterprise Server 15 Xen
  • SUSE Linux Enterprise Server 15 Xen SP1
  • VMware ESXi 6.5 U2
  • VMware ESXi 6.5 U3
  • VMware ESXi 6.7 U1
  • VMware ESXi 6.7 U2
  • VMware ESXi 6.7 U3
  • VMware ESXi 7.0

For a complete list of supported, certified and tested operating systems, plus additional details and links to relevant web sites, see the Operating System Interoperability Guide: https://lenovopress.com/osig#servers=st550-7x09-7x10-sp-gen-2

Virtualization support: The onboard SATA ports of the server can be used with virtualization hypervisors, including VMware ESXi, Linux KVM, Xen, and Microsoft Hyper-V, however support is limited to AHCI (non-RAID) mode. RSTe mode is not supported with virtualization hypervisors.

For configure-to-order configurations, the server can be preloaded with VMware ESXi installed on M.2 cards. Ordering information is listed in the following table.

Table 56. VMware ESXi preload
Part number Feature code Description
CTO only B3VW VMware ESXi 6.5 U2 (Factory Installed)
CTO only B6U0 VMware ESXi 6.5 U3 (factory installed)
CTO only B4XA VMware ESXi 6.7 U1 (Factory Installed)
CTO only B6U1 VMware ESXi 6.7 U2 (factory installed)
CTO only B88T VMware ESXi 6.7 U3 (factory installed)

Physical and electrical specifications

The server features the following dimensions and weight:

  • Tower:
    • Width with stabilizer feet extended: 272 mm (10.7 in)
    • Width with stabilizer feet retracted: 176 mm (6.9 in)
    • Depth: 670 mm (26.4 in)
    • Height: 438 mm (17.2 in)
  • With rack conversion kit:
    • Width: 482 mm (18.97 inches)
    • Depth: 670 mm (26.4 in)
    • Height: 176 mm (6.9 in)

Weight:

  • Fully configured: 36 kg (79.36 lb)

A note about the stabilizer feet: The ST550 includes stabilizer foot stands that are used when the server is in the tower configuration. The stabilizer feet can be installed in a retracted position or in an open position. For safety reasons, it is recommended the feet be used in the open position to help prevent the server from tipping over, however if needed, the feet can be positioned so that they do not extend beyond the width of the server enclosure. When the ST550 is converted to a rack configuration, the feet are removed.

Electrical requirements are as follows:

  • Models with 550 W AC power supplies:
    • 100-127 (nominal) V ac; 50 Hz or 60 Hz; 6.2 A
    • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 3.0 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.16 kVA
      • Maximum configuration: 0.722 kVA
  • Models with 750 W Platinum AC power supplies:
    • 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 8.4 A
    • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.1 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 0.954 kVA
  • Models with 750 W Titanium AC power supplies:
    • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 4.1 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 0.906 kVA
  • Models with 1100 W Platinum AC power supplies:
    • 100 - 127 (nominal) V ac; 50 Hz or 60 Hz; 12.0 A
    • 200 - 240 (nominal) V ac; 50 Hz or 60 Hz; 6.0 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration:  0.12 kVA
      • Maximum configuration: 1.406 kVA

For China customers using 240V DC input power:

  • Models with 550 W 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 2.5 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.16 kVA
      • Maximum configuration: 0.70 kVA
  • Models with 750 W Platinum 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 3.5 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 0.958 kVA
  • Models with 750 W Titanium 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 3.5 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration: 0.15 kVA
      • Maximum configuration: 0.948 kVA
  • Models with 1100 W Platinum 240V DC power supplies:
    • 200 - 240 (nominal) V dc; 5.1 A
    • Input kilovolt-amperes (kVA) (approximately):
      • Minimum configuration:  0.12 kVA
      • Maximum configuration: 1.408 kVA

Operating environment

The ThinkSystem ST550 server complies with ASHRAE Class A2 specifications, and depending on the hardware configuration, also complies with ASHRAE Class A3 and Class A4 specifications. System performance may be impacted when operating temperature is outside ASHRAE A2 specification.

The following restrictions apply with ASHRAE A4 and A3 support:

  • No support for processors with TDP rating of 125 W or higher
  • Two power supplies must be installed; fixed (cabled) power supply not supported
  • The rear fan must be installed
  • No support for NVMe drives
  • No support for GPUs
  • If the media bay conversion kit is installed (adding 4x 2.5-inch drive bays), those drive bays cannot support SAS drives (HDD or SSD) that are 2TB or larger. SATA drives are fully supported.

In addition, CPU core speed may be reduced depending on the processor selected. 

The server is supported operating in the following environments:

  • ASHRAE A2:
    • Temperature: 10°C to 35°C
    • Humidity: 8% to 80%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 300 m above 950 m
  • ASHRAE A3:
    • Temperature: 5°C to 40°C
    • Humidity: 8% to 85%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 175 m above 950 m
  • ASHRAE A4:
    • Temperature: 5°C to 45°C
    • Humidity: 8% to 90%
    • Altitude 0-3000 m (10,000 ft), derated 1°C per 125 m above 950 m

Non-operating environment support:

  • Without packaging:
    • Temperature: -10 °C to 60 °C
    • Humidity: 8 to 90%
  • Storage with packaging:
    • Temperature: -40 °C to 70 °C
    • Humidity: 8 to 90%

Thermal (heat) output:

  • Maximum configuration: 4074 Btu/hr (1194 watts)

Acoustical noise emissions:

  • Sound power levels (bels):
    • Base configuration: 4.0 bels (idle), 4.1 bels (operating)
    • Maximum configuration: 5.3 bels (idle), 5.3 bels (operating)
  • Sound pressure levels (dBA):
    • Base configuration: 33 dBA (idle), 33 dBA (operating)
    • Maximum configuration: 43 dBA (idle), 43 dBA (operating)

The server has the following vibration and shock limits:

  • Vibration:
    • Operating: 0.21 G rms at 5 Hz to 500 Hz for 15 minutes across 3 axes
    • Non-operating: 1.04 G rms at 2 Hz to 200 Hz for 15 minutes across 6 surfaces
  • Shock:
    • Operating: 15 G for 3 milliseconds in each direction (positive and negative X, Y, and Z axes)
    • Non-operating:
      • 12 kg - 22 kg: 50 G for 152 in./sec velocity change across 6 surfaces
      • 23 kg  - 31 kg: 35 G for 152 in./sec velocity change across 6 surfaces

Warranty and Support

The ST550 has a 1-year or 3-year warranty, based on the machine type of the system:

  • 7X09: 1 year warranty
  • 7X10: 3 year warranty

The standard warranty terms are customer-replaceable unit (CRU) and onsite (for field-replaceable units FRUs only) with standard call center support during normal business hours and 9x5 Next Business Day Parts Delivered.

Lenovo’s additional support services provide a sophisticated, unified support structure for your data center, with an experience consistently ranked number one in customer satisfaction worldwide. Available offerings include:

  • Premier Support

    Premier Support provides a Lenovo-owned customer experience and delivers direct access to technicians skilled in hardware, software, and advanced troubleshooting, in addition to the following:

    • Direct technician-to-technician access through a dedicated phone line
    • 24x7x365 remote support
    • Single point of contact service
    • End to end case management
    • Third-party collaborative software support
    • Online case tools and live chat support
    • On-demand remote system analysis
  • Warranty Upgrade (Preconfigured Support)

    Services are available to meet the on-site response time targets that match the criticality of your systems.

    • 3, 4, or 5 years of service coverage
    • 1-year or 2-year post-warranty extensions
    • Foundation Service: 9x5 service coverage with next business day onsite response. YourDrive YourData is an optional extra (see below).
    • Essential Service: 24x7 service coverage with 4-hour onsite response or 24-hour committed repair (available only in select countries). Bundled with YourDrive YourData.
    • Advanced Service: 24x7 service coverage with 2-hour onsite response or 6-hour committed repair (available only in select countries). Bundled with YourDrive YourData.
  • Managed Services

    Lenovo Managed Services provides continuous 24x7 remote monitoring (plus 24x7 call center availability) and proactive management of a your data center using state of the art tools, systems, and practices by a team of highly skilled and experienced Lenovo services professionals.

    Quarterly reviews check error logs, verify firmware & OS device driver levels, and software as needed. We’ll also maintain records of latest patches, critical updates, and firmware levels, to ensure you systems are providing business value through optimized performance.

  • Technical Account Management (TAM)

    A Lenovo Technical Account Manager helps you optimize the operation of your data center based on a deep understanding of your business. You gain direct access to your Lenovo TAM, who serves as your single point of contact to expedite service requests, provide status updates, and furnish reports to track incidents over time. In addition, your TAM will help proactively make service recommendations and manage your service relationship with Lenovo to make certain your needs are met.

  • Enterprise Server Software Support

    Enterprise Software Support is an additional support service providing customers with software support on Microsoft, Red Hat, SUSE, and VMware applications and systems. Around the clock availability for critical problems plus unlimited calls and incidents helps customers address challenges fast, without incremental costs. Support staff can answer troubleshooting and diagnostic questions, address product comparability and interoperability issues, isolate causes of problems, report defects to software vendors, and more.

  • YourDrive YourData

    Lenovo’s YourDrive YourData is a multi-drive retention offering that ensures your data is always under your control, regardless of the number of drives that are installed in your Lenovo server. In the unlikely event of a drive failure, you retain possession of your drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The YourDrive YourData service can be purchased in convenient bundles, and is optional with Foundation Service. It is bundled with Essential Service and Advanced Service.

  • Health Check

    Having a trusted partner who can perform regular and detailed health checks is central to maintaining efficiency and ensuring that your systems and business are always running at their best. Health Check supports Lenovo-branded server, storage, and networking devices, as well as select Lenovo-supported products from other vendors that are sold by Lenovo or a Lenovo-Authorized Reseller.

Examples of region-specific warranty terms are second or longer business day parts delivery or parts-only base warranty.

If warranty terms and conditions include onsite labor for repair or replacement of parts, Lenovo will dispatch a service technician to the customer site to perform the replacement. Onsite labor under base warranty is limited to labor for replacement of parts that have been determined to be field-replaceable units (FRUs). Parts that are determined to be customer-replaceable units (CRUs) do not include onsite labor under base warranty.

If warranty terms include parts-only base warranty, Lenovo is responsible for delivering only replacement parts that are under base warranty (including FRUs) that will be sent to a requested location for self-service. Parts-only service does not include a service technician being dispatched onsite. Parts must be changed at customer’s own cost and labor and defective parts must be returned following the instructions supplied with the spares parts.

Lenovo Service offerings are region-specific. Not all preconfigured support and upgrade options are available in every region. For information about Lenovo service upgrade offerings that are available in your region, refer to the following resources:

For service definitions, region-specific details, and service limitations, please refer to the following documents:

Services

Lenovo Services is a dedicated partner to your success. Our goal is to reduce your capital outlays, mitigate your IT risks, and accelerate your time to productivity.

Here’s a more in-depth look at what we can do for you:

  • Asset Recovery Services

    Asset Recovery Services (ARS) helps customers recover the maximum value from their end-of-life equipment in a cost-effective and secure way. On top of simplifying the transition from old to new equipment, ARS mitigates environmental and data security risks associated with data center equipment disposal. Lenovo ARS is a cash-back solution for equipment based on its remaining market value, yielding maximum value from aging assets and lowering total cost of ownership for your customers. For more information, see the ARS page, https://lenovopress.com/lp1266-reduce-e-waste-and-grow-your-bottom-line-with-lenovo-ars.

  • Assessment Services

    An Assessment helps solve your IT challenges through an onsite, multi-day session with a Lenovo technology expert. We perform a tools based assessment which provides a comprehensive and thorough review of a company's environment and technology systems. In addition to the technology based functional requirements, the consultant also discusses and records the non-functional business requirements, challenges, and constraints. Assessments help organizations like yours, no matter how large or small, get a better return on your IT investment and overcome challenges in the ever-changing technology landscape.

  • Design Services

    Professional Services consultants perform infrastructure design and implementation planning to support your strategy. The high-level architectures provided by the assessment service are turned into low level designs and wiring diagrams, which are reviewed and approved prior to implementation The implementation plan will demonstrate an outcome-based proposal to provide business capabilities through infrastructure with a risk-mitigated project plan.

  • Basic Hardware Installation

    Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities.

  • Deployment Services

    When investing in new IT infrastructures, you need to ensure your business will see quick time to value with little to no disruption. Lenovo deployments are designed by development and engineering teams who know our Products & Solutions better than anyone else, and our technicians own the process from delivery to completion. Lenovo will conduct remote preparation and planning, configure & integrate systems, validate systems, verify and update appliance firmware, train on administrative tasks, and provide post-deployment documentation. Customer’s IT teams leverage our skills to enable IT staff to transform with higher level roles and tasks.

  • Integration, Migration, and Expansion Services

    Move existing physical & virtual workloads easily, or determine technical requirements to support increased workloads while maximizing performance. Includes tuning, validation, and documenting ongoing run processes. Leverage migration assessment planning documents to perform necessary migrations.

Some service options may not be available in all countries. For more information, go to https://www.lenovo.com/systems/services. For information about Lenovo service upgrade offerings that are available in your region, contact your local Lenovo sales representative or business partner.

Regulatory compliance

The ST550 server conforms to the following standards:

  • Energy Star 2.1
  • FCC - Verified to comply with Part 15 of the FCC Rules, Class A
  • Canada ICES-003, issue 6, Class A
  • UL/IEC 60950-1
  • CSA C22.2 No. 60950-1
  • IEC 62368-1:2014 (CB Certificate and CB Test Report)
  • NOM-019
  • Argentina IEC60950-1
  • Japan VCCI, Class A
  • Australia/New Zealand AS/NZS CISPR 32, Class A; AS/NZS 60950.1
  • China CCC GB4943.1, GB9254 Class A, GB17625.1
  • Taiwan BSMI CNS13438, Class A; CNS14336-1; CNS15663
  • Korea KN32, Class A; KN35
  • Russia, Belorussia and Kazakhstan, TR CU 020/2011 (for EMC) and TR CU 004/2011 (for safety)
  • IEC 60950-1 (CB Certificate and CB Test Report)
  • CE Mark (EN55032 Class A, EN60950-1, EN55024, EN61000-3-2, EN61000-3-3)
  • CISPR 32, Class A
  • TUV-GS (EN60950-1 /IEC60950-1,EK1-ITB2000)
  • RoHS Directive
  • ErP lot3
  • JESL

External drive enclosures

The server supports attachment to external drive enclosures using a RAID controller with external ports or a SAS host bus adapter. Adapters supported by the server are listed in the SAS adapters for external storage section.

Note: Information provided in this section is for ordering reference purposes only. For the operating system and adapter support details, refer to the interoperability matrix for a particular storage enclosure that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com

Table 57. External drive enclosures
Description Part number
Worldwide Japan PRC
Lenovo Storage D1212 LFF Disk Expansion with Dual SAS IO Modules 4587A11 4587A1J 4587A1C
Lenovo Storage D1224 SFF Disk Expansion with Dual SAS IO Modules 4587A31 4587A3J 4587A3C
Lenovo Storage D3284 4TB x 84 HD Expansion Enclosure 641311F
Lenovo Storage D3284 6TB x 84 HD Expansion Enclosure 641312F
Lenovo Storage D3284 8TB x 84 HD Expansion Enclosure 641313F
Lenovo Storage D3284 10TB x 84 HD Expansion Enclosure 641314F

For details about supported drives, adapters, and cables, see the following Lenovo Press Product Guides:

External storage systems

The following table lists the external storage systems that are currently offered by Lenovo.

Note: Information provided in this section is for ordering reference purposes only. End-to-end storage configuration support must be verified through the interoperability matrix for a particular storage system that can be found on the Lenovo Data Center Support web site:
http://datacentersupport.lenovo.com

Table 58. External storage systems: DE Series
Description Part number
Worldwide Japan
Lenovo ThinkSystem DE Series Storage (SAS connectivity)
Lenovo ThinkSystem DE2000H SAS Hybrid Flash Array LFF (16 GB cache) 7Y70A000WW 7Y701003JP
Lenovo ThinkSystem DE2000H SAS Hybrid Flash Array SFF (16 GB cache) 7Y71A000WW 7Y711003JP
Lenovo ThinkSystem DE4000H SAS Hybrid Flash Array 4U60 (16 GB cache) 7Y77A002WW 7Y771000JP
Lenovo ThinkSystem DE4000H SAS Hybrid Flash Array LFF (16 GB cache) 7Y74A000WW 7Y74A000JP
Lenovo ThinkSystem DE4000H SAS Hybrid Flash Array SFF (16 GB cache) 7Y75A000WW 7Y75A000JP
Lenovo ThinkSystem DE4000F SAS All Flash Array SFF (16 GB cache) 7Y76A000WW 7Y76A000JP
Lenovo ThinkSystem DE4000F SAS All Flash Array SFF (64 GB cache) 7Y76A005WW 7Y76A008JP
Lenovo ThinkSystem DE6000H SAS Hybrid Flash Array 4U60 (32 GB cache) 7Y80A000WW 7Y801002JP
Lenovo ThinkSystem DE6000H SAS Hybrid Flash Array SFF (32 GB cache) 7Y78A000WW 7Y781002JP
Lenovo ThinkSystem DE6000F SAS All Flash Array SFF (128 GB cache) 7Y79A000WW 7Y79A000JP
Lenovo ThinkSystem DE Series Storage (iSCSI connectivity)
Lenovo ThinkSystem DE2000H 10GBASE-T Hybrid Flash Array LFF (16 GB cache) 7Y70A003WW 7Y701001JP
Lenovo ThinkSystem DE2000H 10GBASE-T Hybrid Flash Array SFF (16 GB cache) 7Y71A002WW 7Y711005JP
Lenovo ThinkSystem DE2000H iSCSI Hybrid Flash Array LFF (16 GB cache) 7Y70A004WW 7Y701000JP
Lenovo ThinkSystem DE2000H iSCSI Hybrid Flash Array SFF (16 GB cache) 7Y71A003WW 7Y711006JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array 4U60 (16 GB cache) 7Y77A000WW 7Y771002JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array LFF (16 GB cache) 7Y74A002WW 7Y74A002JP
Lenovo ThinkSystem DE4000H iSCSI Hybrid Flash Array SFF (16 GB cache) 7Y75A001WW 7Y75A001JP
Lenovo ThinkSystem DE4000F iSCSI All Flash Array SFF (16 GB cache) 7Y76A002WW 7Y76A002JP
Lenovo ThinkSystem DE4000F iSCSI All Flash Array SFF (64 GB cache) 7Y76A007WW 7Y76A00AJP
Lenovo ThinkSystem DE6000H iSCSI Hybrid Flash Array 4U60 (32 GB cache) 7Y80A002WW 7Y801000JP
Lenovo ThinkSystem DE6000H iSCSI Hybrid Flash Array SFF (32 GB cache) 7Y78A002WW 7Y781000JP
Lenovo ThinkSystem DE6000F iSCSI All Flash Array SFF (128 GB cache) 7Y79A002WW 7Y79A002JP
Lenovo ThinkSystem DE Series Storage (FC connectivity)
Lenovo ThinkSystem DE2000H FC Hybrid Flash Array LFF (16 GB cache) 7Y70A002WW 7Y701002JP
Lenovo ThinkSystem DE2000H FC Hybrid Flash Array SFF (16 GB cache) 7Y71A001WW 7Y711004JP
Lenovo ThinkSystem DE4000H FC Hybrid Flash Array 4U60 (16 GB cache) 7Y77A001WW 7Y771001JP
Lenovo ThinkSystem DE4000H FC Hybrid Flash Array LFF (16 GB cache) 7Y74A001WW 7Y74A001JP
Lenovo ThinkSystem DE4000H FC Hybrid Flash Array SFF (16 GB cache) 7Y75A002WW 7Y75A002JP
Lenovo ThinkSystem DE4000F FC All Flash Array SFF (16 GB cache) 7Y76A001WW 7Y76A001JP
Lenovo ThinkSystem DE4000F FC All Flash Array SFF (64 GB cache) 7Y76A006WW 7Y76A009JP
Lenovo ThinkSystem DE6000H FC Hybrid Flash Array 4U60 (32 GB cache) 7Y80A001WW 7Y801001JP
Lenovo ThinkSystem DE6000H FC Hybrid Flash Array SFF (32 GB cache) 7Y78A001WW 7Y781001JP
Lenovo ThinkSystem DE6000F FC All Flash Array SFF (128 GB cache) 7Y79A001WW 7Y79A001JP
Table 59. External storage systems: DM Series
Description Part number
Lenovo ThinkSystem DM Series Storage (NAS or iSCSI connectivity)
ThinkSystem DM3000H, 48TB (12x 4TB HDDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y421003EA*
ThinkSystem DM3000H, 48TB (12x 4TB HDDs), 10GBASE-T, ONTAP 9.5 7Y421007EA*
ThinkSystem DM3000H, 96TB (12x 8TB HDDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y421005EA*
ThinkSystem DM3000H, 96TB (12x 8TB HDDs), 10GBASE-T, ONTAP 9.5 7Y421001EA*
ThinkSystem DM5000H, 11.5TB (12x 960GB SSDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y571004EA*
ThinkSystem DM5000H, 11.5TB (12x 960GB SSDs), 10GBASE-T, ONTAP 9.5 7Y57100LEA*
ThinkSystem DM5000H, 14.4TB (12x 1.2TB HDDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y57100CEA*
ThinkSystem DM5000H, 21.6TB (12x 1.8TB HDDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y57100GEA*
ThinkSystem DM5000H, 23TB (24x 960GB SSDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y571006EA*
ThinkSystem DM5000H, 23TB (24x 960GB SSDs), 10GBASE-T, ONTAP 9.5 7Y57100NEA*
ThinkSystem DM5000H, 28.8TB (24x 1.2TB HDDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y57100EEA*
ThinkSystem DM5000H, 28.8TB (24x 1.2TB HDDs), 10GBASE-T, ONTAP 9.5 7Y57100VEA*
ThinkSystem DM5000H, 43.2TB (24x 1.8TB HDDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y57100JEA*
ThinkSystem DM5000H, 43.2TB (24x 1.8TB HDDs), 10GBASE-T, ONTAP 9.5 7Y571002EA*
ThinkSystem DM5000H, 46TB (12x 3.84TB SSDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y571008EA*
ThinkSystem DM5000H, 46TB (12x 3.84TB SSDs), 10GBASE-T, ONTAP 9.5 7Y57100QEA*
ThinkSystem DM5000H, 92TB (24x 3.84TB SSDs), 10GBASE-T, ONTAP 9.5 Fundamentals 7Y57100AEA*
ThinkSystem DM5000H, 92TB (24x 3.84TB SSDs), 10GBASE-T, ONTAP 9.5 7Y57100REA*
ThinkSystem DM5000F, 11.5TB (12x 960GB SSDs), 10GBASE-T, ONTAP 9.5 7Y411002EA*
ThinkSystem DM5000F, 23TB (24x 960GB SSDs), 10GBASE-T, ONTAP 9.5 7Y411004EA*
ThinkSystem DM5000F, 46TB (12x 3.84TB SSDs), 10GBASE-T, ONTAP 9.5 7Y411006EA*
ThinkSystem DM5000F, 92TB (24x 3.84TB SSDs), 10GBASE-T, ONTAP 9.5 7Y411007EA*
Lenovo ThinkSystem DM Series Storage (NAS, iSCSI, or FC connectivity)
ThinkSystem DM3000H Hybrid Storage Array (2U12 LFF, CTO only) 7Y42CTO1WW
ThinkSystem DM3000H, 48TB (12x 4TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y421009NA*
ThinkSystem DM3000H, 48TB (12x 4TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y421002EA*
ThinkSystem DM3000H, 48TB (12x 4TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y421006EA*
ThinkSystem DM3000H, 96TB (12x 8TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y421004EA*
ThinkSystem DM3000H, 96TB (12x 8TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y421008EA*
ThinkSystem DM5000H Hybrid Storage Array (2U24 SFF, CTO only) 7Y57CTO1WW
ThinkSystem DM5000H, 11.5TB (12x 960GB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y571011NA*
ThinkSystem DM5000H, 11.5TB (12x 960GB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y571003EA*
ThinkSystem DM5000H, 11.5TB (12x 960GB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y57100KEA*
ThinkSystem DM5000H, 14.4TB (12x 1.2TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y57100BEA*
ThinkSystem DM5000H, 21.6TB (12x 1.8TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y57100FEA*
ThinkSystem DM5000H, 23TB (24x 960GB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y571005EA*
ThinkSystem DM5000H, 23TB (24x 960GB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y57100MEA*
ThinkSystem DM5000H, 28.8TB (24x 1.2TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y57100DEA*
ThinkSystem DM5000H, 43.2TB (24x 1.8TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y571010NA*
ThinkSystem DM5000H, 43.2TB (24x 1.8TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y57100HEA*
ThinkSystem DM5000H, 43.2TB (24x 1.8TB HDDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y57100ZEA*
ThinkSystem DM5000H, 46TB (12x 3.84TB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y571007EA*
ThinkSystem DM5000H,  46TB (12x 3.84TB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y57100PEA*
ThinkSystem DM5000H, 92TB (24x 3.84TB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 Fundamentals 7Y571009EA*
ThinkSystem DM5000H, 92TB (24x 3.84TB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y57100SEA*
ThinkSystem DM5000F Flash Storage Array (2U24 SFF, CTO only) 7Y41CTO1WW
ThinkSystem DM5000F, 11.5TB (12x 960GB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y411001EA*
ThinkSystem DM5000F, 23TB (24x 960GB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y411003EA*
ThinkSystem DM5000F, 46TB (12x 3.84TB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y411005EA*
ThinkSystem DM5000F, 92TB (24x 3.84TB SSDs), 16Gb FC / 10GbE SFP+, ONTAP 9.5 7Y411000EA*
ThinkSystem DM7000H Hybrid Storage Array (3U, CTO only) 7Y56CTO1WW
ThinkSystem DM7000F Flash Storage Array (3U, CTO only) 7Y40CTO1WW
ThinkSystem DM7100H Hybrid Storage Array (4U, CTO only) 7D26CTO1WW
ThinkSystem DM7100F Flash Storage Array (4U, CTO only) 7D25CTO1WW

* Preconfigured models that are available only in North America (part numbers that have NA at the end) or EMEA (part numbers that have EA at the end) and require Preconfigured support to be purchased with the storage system (See the respective product guide for details).

For more information, see the list of Product Guides in the Lenovo Storage category:
http://lenovopress.com/storage/san/lenovo#rt=product-guide

External backup units

The following table lists the available external SAS tape backup options.

Tip: Verify the end-to-end support of an IBM tape backup solution through the IBM System Storage Interoperation Center (SSIC): http://www.ibm.com/systems/support/storage/ssic

Table 60. External SAS backup options
Part number Description
External SAS tape backup drives
6160S6E IBM TS2260 Tape Drive Model H6S
6160S7E IBM TS2270 Tape Drive Model H7S
6160S8E IBM TS2280 Tape Drive Model H8S
External SAS tape backup autoloaders
6171S6R IBM TS2900 Tape Autoloader w/LTO6 HH SAS
6171S7R IBM TS2900 Tape Autoloader w/LTO7 HH SAS
6171S8R IBM TS2900 Tape Autoloader w/LTO8 HH SAS
External tape backup libraries
6741A1F IBM TS4300 3U Tape Library-Base Unit
SAS backup drives for TS4300 Tape Library
01KP934 LTO 6 HH SAS Drive
01KP937 LTO 7 HH SAS Drive
01KP953 LTO 8 HH SAS Drive

For more information, see the list of Product Guides in the Backup units category:
https://lenovopress.com/servers/options/backup

Top-of-rack Ethernet switches

The following table lists the Ethernet LAN switches that are offered by Lenovo.

Table 61. Ethernet LAN switches
Part number Description
1 Gb Ethernet Rack switches
7Y810011WW Lenovo ThinkSystem NE0152T RackSwitch (Rear to Front)
7Z320O11WW Lenovo ThinkSystem NE0152TO RackSwitch (Rear to Front, ONIE)
7159BAX Lenovo RackSwitch G7028 (Rear to Front)
7159CAX Lenovo RackSwitch G7052 (Rear to Front)
7159G52 Lenovo RackSwitch G8052 (Rear to Front)
7165H1X Juniper EX2300-C PoE Switch
7165H2X Juniper EX2300-24p PoE Switch
1 Gb Ethernet Campus switches
7Z340011WW Lenovo CE0128TB Switch (3-Year Warranty)
7Z360011WW Lenovo CE0128TB Switch (Limited Lifetime Warranty)
7Z340012WW Lenovo CE0128PB Switch (3-Year Warranty)
7Z360012WW Lenovo CE0128PB Switch (Limited Lifetime Warranty)
7Z350021WW Lenovo CE0152TB Switch (3-Year Warranty)
7Z370021WW Lenovo CE0152TB Switch (Limited Lifetime Warranty)
7Z350022WW Lenovo CE0152PB Switch (3-Year Warranty)
7Z370022WW Lenovo CE0152PB Switch (Limited Lifetime Warranty)
10 Gb Ethernet switches
7159A1X Lenovo ThinkSystem NE1032 RackSwitch (Rear to Front)
7159B1X Lenovo ThinkSystem NE1032T RackSwitch (Rear to Front)
7Z330O11WW Lenovo ThinkSystem NE1064TO RackSwitch (Rear to Front, ONIE)
7159C1X Lenovo ThinkSystem NE1072T RackSwitch (Rear to Front)
7159CRW Lenovo RackSwitch G8272 (Rear to Front)
7159GR6 Lenovo RackSwitch G8296 (Rear to Front)
25 Gb Ethernet switches
7159E1X Lenovo ThinkSystem NE2572 RackSwitch (Rear to Front)
7Z210O21WW Lenovo ThinkSystem NE2572O RackSwitch (Rear to Front, ONIE)
7Z330O21WW Lenovo ThinkSystem NE2580O RackSwitch (Rear to Front, ONIE)
100 Gb Ethernet switches
7159D1X Lenovo ThinkSystem NE10032 RackSwitch (Rear to Front)
7Z210O11WW Lenovo ThinkSystem NE10032O RackSwitch (Rear to Front, ONIE)

For more information, see the list of Product Guides in the following switch categories:

Fibre Channel SAN switches

The following table lists the Fibre Channel SAN switches that are offered by Lenovo and can be used with this system.

Table 62. Fibre Channel SAN switches
Description Part number
8 Gb FC
Lenovo B300, E_Port License, 8 ports licensed, 8x 8Gb SWL SFPs, 1 PS, Rail Kit, 1Yr FW 3873AR6
16 Gb FC
Lenovo ThinkSystem DB610S, 8 ports licensed, 8x 16Gb SWL SFPs, 1 PS, Rail Kit, 1Yr FW 6559F2A
Lenovo ThinkSystem DB610S, ENT., 24 ports licensed, 24x 16Gb SWL SFPs, 1 PS, Rail Kit, 1Yr FW 6559F1A
Lenovo ThinkSystem DB620S, 24 ports licensed, 24x 16Gb SWL SFPs, 2 PS, Rail Kit, 1Yr FW 6415J1A
Lenovo B6505, 12 ports licensed, 12x 16Gb SWL SFPs, 1 PS, Rail Kit, 1Yr FW 3873ER1
Lenovo B6510, 24 ports licensed, 24x 16Gb SWL SFPs, 2 PS, Rail Kit, 1Yr FW 3873IR1
Lenovo B6510, 24 ports licensed, 24x 16Gb SWL SFPs, 2 PS, Rail Kit, 3Yr FW 3873BR3
32 Gb FC
Lenovo ThinkSystem DB610S, 8 ports licensed, No SFPs, 1 PS, Rail Kit, 1Yr FW 6559F3A
Lenovo ThinkSystem DB620S, 24 ports licensed, No SFPs, 2 PS, Rail Kit, 1Yr FW 6415G3A
Lenovo ThinkSystem DB620S, 24 ports licensed, 24x 32Gb SWL SFPs, 2 PS, Rail Kit, 1Yr FW 6415H11
Lenovo ThinkSystem DB620S, ENT., 48 ports licensed, 48x 32Gb SWL SFPs, 2 PS, Rail Kit, 1Yr FW 6415H2A
Lenovo ThinkSystem DB630S, 48 ports licensed, No SFPs, 2 PS, Rail Kit, 1Yr FW 7D1SA001WW
Lenovo ThinkSystem DB630S, 48 ports licensed, 48x 32Gb SWL SFPs, 2 PS, Rail Kit, 1Yr FW 7D1SA002WW
Lenovo ThinkSystem DB630S, ENT., 96 ports licensed, 96x 32Gb SWL SFPs, 2 PS, Rail Kit, 1Yr FW 7D1SA003WW
Lenovo ThinkSystem DB400D 32Gb FC Director, ENT., 4 Blade slots, 8U, 1Yr FW 6684D2A
Lenovo ThinkSystem DB400D 32Gb FC Director, ENT., 4 Blade slots, 8U, 3Yr FW 6684B2A
Lenovo ThinkSystem DB800D 32Gb FC Director, ENT., 8 Blade slots, 14U, 1Yr FW 6682D1A

For more information, see the list of Product Guides in the Rack SAN Switches category:
http://lenovopress.com/storage/switches/rack#rt=product-guide

Uninterruptible power supply units

The server supports attachments to the uninterruptible power supply (UPS) units that are listed in the following table.

Table 63. Uninterruptible power supply units
Part number Description
Tower UPS units
55951AX T1kVA Tower UPS (100-125VAC)
55951KX T1kVA Tower UPS (200-240VAC)
55952AX T1.5kVA Tower UPS (100-125VAC)
55952KX T1.5kVA Tower UPS (200-240VAC)
Rack-mounted or tower UPS units
55941AX RT1.5kVA 2U Rack or Tower UPS (100-125VAC)
55941KX RT1.5kVA 2U Rack or Tower UPS (200-240VAC)
55942AX RT2.2kVA 2U Rack or Tower UPS (100-125VAC)
55942KX RT2.2kVA 2U Rack or Tower UPS (200-240VAC)
55943AX RT3kVA 2U Rack or Tower UPS (100-125VAC)
55943KX RT3kVA 2U Rack or Tower UPS (200-240VAC)
55945KX RT5kVA 3U Rack or Tower UPS (200-240VAC)
55946KX RT6kVA 3U Rack or Tower UPS (200-240VAC)
55948KX RT8kVA 6U Rack or Tower UPS (200-240VAC)
55949KX RT11kVA 6U Rack or Tower UPS (200-240VAC)
55948PX RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
55949PX RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC)
Rack-mounted UPS units
55943KT† ThinkSystem RT3kVA 2U Standard UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55943LT† ThinkSystem RT3kVA 2U Long Backup UPS (200-230VAC) (2x C13 10A, 2x GB 10A, 1x C19 16A outlets)
55946KT† ThinkSystem RT6kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)
5594XKT† ThinkSystem RT10kVA 5U UPS (200-230VAC) (2x C13 10A outlets, 1x Terminal Block output)

† Only available in China and countries in the Asia Pacific region.

For more information, see the list of Product Guides in the UPS category:
https://lenovopress.com/servers/options/ups

Power distribution units

The following table lists the power distribution units (PDUs) that are offered by Lenovo.

Table 64. Power distribution units
Part number Description
0U Basic PDUs
00YJ776 0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord
00YJ777 0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord
00YJ778 0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line cord
00YJ779 0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord
Switched and Monitored PDUs
00YJ780 0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6 line cord
00YJ781 0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P line cord
00YJ782 0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309 532P6 cord
00YJ783 0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9 line cord
46M4002* 1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)
46M4003* 1U 9 C19/3 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
46M4004* 1U 12 C13 Switched and Monitored DPI PDU (without line cord)
46M4005* 1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line cord
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
71762NX Ultra Density Enterprise C19/C13 PDU Module (without line cord)
71763NU Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line cord
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
39M2816 DPI C13 Enterprise PDU+ (without line cord)
39Y8941 DPI Single Phase C13 Enterprise PDU (without line cord)
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
39Y8948 DPI Single Phase C19 Enterprise PDU (without line cord)
39Y8923 DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord
Front-end PDUs (3x IEC 320 C19 outlets)
39Y8938 DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord
39Y8939 DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord
39Y8934 DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
39Y8940 DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
39Y8935 DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord
NEMA PDUs (6x NEMA 5-15R outlets)
39Y8905 DPI 100-127V PDU with Fixed NEMA L5-15P line cord
Line cords for PDUs that ship without a line cord
40K9611 DPI 32a Line Cord (IEC 309 3P+N+G)
40K9612 DPI 32a Line Cord (IEC 309 P+N+G)
40K9613 DPI 63a Cord (IEC 309 P+N+G)
40K9614 DPI 30a Line Cord (NEMA L6-30P)
40K9615 DPI 60a Cord (IEC 309 2P+G)
40K9617 DPI Australian/NZ 3112 Line Cord
40K9618 DPI  Korean 8305 Line Cord

* Not available in USA and Canada

For more information, see the Lenovo Press documents in the PDU category:
https://lenovopress.com/servers/options/pdu

Rack cabinets

Rack installation kits are described in the Rack installation section.

The following table lists the supported rack cabinets.

Table 65. Rack cabinets
Part number Description
7D2B0001WW / 7D2N0001WW 12U 1200mm Deep Micro Datacenter Rack
7D2C0001WW / 7D2P0001WW 18U 1200mm Deep Micro Datacenter Rack
93072RX 25U Standard Rack
93072PX 25U Static S2 Standard Rack
93634PX 42U 1100mm Dynamic Rack
93634EX 42U 1100mm Dynamic Expansion Rack
93604PX 42U 1200mm Deep Dynamic Rack
93614PX 42U 1200mm Deep Static Rack
93084EX 42U Enterprise Expansion Rack
93084PX 42U Enterprise Rack
93074RX 42U Standard Rack
Withdrawn rack cabinets
201886X* 11U Office Enablement Kit
93604EX* 42U 1200mm Deep Dynamic Expansion Rack
93614EX* 42U 1200mm Deep Static Expansion Rack
93074XX* 42U Standard Rack Extension
93624PX* 47U 1200mm Deep Static Rack
93624EX* 47U 1200mm Deep Static Expansion Rack
93634BX* PureFlex System 42U Expansion Rack
93634DX* PureFlex System 42U Expansion Rack
93634AX* PureFlex System 42U Rack
93634CX* PureFlex System 42U Rack

* Withdrawn from marketing

For specifications about these racks, see the Lenovo Rack Cabinet Reference, available from:
https://lenovopress.com/lp1287-lenovo-rack-cabinet-reference

For more information, see the list of Product Guides in the Rack cabinets category:
https://lenovopress.com/servers/options/racks

KVM console options

The following table lists the supported KVM consoles, keyboards, and KVM switches.

Table 66. Console keyboards
Part number Description
Consoles
17238BX 1U 18.5" Standard Console (without keyboard)
Console keyboards
7ZB7A05469 ThinkSystem Keyboard w/ Int. Pointing Device USB - Arabic 253 RoHS v2
7ZB7A05468 ThinkSystem Keyboard w/ Int. Pointing Device USB - Belg/UK 120 RoHS v2
7ZB7A05206 ThinkSystem Keyboard w/ Int. Pointing Device USB - Czech 489 RoHS v2
7ZB7A05207 ThinkSystem Keyboard w/ Int. Pointing Device USB - Danish 159 RoHS v2
7ZB7A05208 ThinkSystem Keyboard w/ Int. Pointing Device USB - Dutch 143 RoHS v2
7ZB7A05210 ThinkSystem Keyboard w/ Int. Pointing Device USB - Fr/Canada 445 RoHS v2
7ZB7A05209 ThinkSystem Keyboard w/ Int. Pointing Device USB - French 189 RoHS v2
7ZB7A05211 ThinkSystem Keyboard w/ Int. Pointing Device USB - German 129 RoHS v2
7ZB7A05212 ThinkSystem Keyboard w/ Int. Pointing Device USB - Greek 219 RoHS v2
7ZB7A05213 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hebrew 212 RoHS v2
7ZB7A05214 ThinkSystem Keyboard w/ Int. Pointing Device USB - Hungarian 208 RoHS v2
7ZB7A05215 ThinkSystem Keyboard w/ Int. Pointing Device USB - Italian 141 RoHS v2
7ZB7A05216 ThinkSystem Keyboard w/ Int. Pointing Device USB - Japanese 194 RoHS v2
7ZB7A05217 ThinkSystem Keyboard w/ Int. Pointing Device USB - Korean 413 RoHS v2
7ZB7A05218 ThinkSystem Keyboard w/ Int. Pointing Device USB - LA Span 171 RoHS v2
7ZB7A05219 ThinkSystem Keyboard w/ Int. Pointing Device USB - Norwegian 155 RoHS v2
7ZB7A05220 ThinkSystem Keyboard w/ Int. Pointing Device USB - Polish 214 RoHS v2
7ZB7A05221 ThinkSystem Keyboard w/ Int. Pointing Device USB - Portuguese 163 RoHS v2
7ZB7A05222 ThinkSystem Keyboard w/ Int. Pointing Device USB - Russian 441 RoHS v2
7ZB7A05223 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovak 245 RoHS v2
7ZB7A05231 ThinkSystem Keyboard w/ Int. Pointing Device USB - Slovenian 234 RoHS v2
7ZB7A05224 ThinkSystem Keyboard w/ Int. Pointing Device USB - Spanish 172 RoHS v2
7ZB7A05225 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swed/Finn 153 RoHS v2
7ZB7A05226 ThinkSystem Keyboard w/ Int. Pointing Device USB - Swiss F/G 150 RoHS v2
7ZB7A05227 ThinkSystem Keyboard w/ Int. Pointing Device USB - Thai 191 RoHS v2
7ZB7A05467 ThinkSystem Keyboard w/ Int. Pointing Device USB - Trad Chinese/US 467 RoHS v2
7ZB7A05228 ThinkSystem Keyboard w/ Int. Pointing Device USB - Turkish 179 RoHS v2
7ZB7A05229 ThinkSystem Keyboard w/ Int. Pointing Device USB - UK Eng 166 RoHS v2
7ZB7A05470 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Eng 103P RoHS v2
7ZB7A05230 ThinkSystem Keyboard w/ Int. Pointing Device USB - US Euro 103P RoHS v2
ThinkSystem Digital and Analog KVM Console switches and cables
1754D1T ThinkSystem Digital 2x1x16 KVM Switch (DVI video output port)
1754A1T ThinkSystem Analog 1x8 KVM Switch (DVI video output port)
4X97A11108 ThinkSystem VGA to DVI Conversion Cable
4X97A11109 ThinkSystem Single-USB Conversion Cable for Digital KVM
4X97A11107 ThinkSystem Dual-USB Conversion Cable for Digital KVM
4X97A11106 ThinkSystem USB Conversion Cable for Analog KVM
GCM and LCM Console switches and cables
1754D2X Global 4x2x32 Console Manager (GCM32)
1754D1X Global 2x2x16 Console Manager (GCM16)
1754A2X Local 2x16 Console Manager (LCM16)
1754A1X Local 1x8 Console Manager (LCM8)
43V6147 Single Cable USB Conversion Option (UCO)
39M2895 USB Conversion Option (4 Pack UCO)
46M5383 Virtual Media Conversion Option Gen2 (VCO2)
46M5382 Serial Conversion Option (SCO)

For more information, see the list of Product Guides in the KVM Switches and Consoles category:
http://lenovopress.com/servers/options/kvm

Lenovo Financial Services

Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering products and services that are recognized for their quality, excellence, and trustworthiness. Lenovo Financial Services offers financing solutions and services that complement your technology solution anywhere in the world.

We are dedicated to delivering a positive finance experience for customers like you who want to maximize your purchase power by obtaining the technology you need today, protect against technology obsolescence, and preserve your capital for other uses.

We work with businesses, non-profit organizations, governments and educational institutions to finance their entire technology solution. We focus on making it easy to do business with us. Our highly experienced team of finance professionals operates in a work culture that emphasizes the importance of providing outstanding customer service. Our systems, processes and flexible policies support our goal of providing customers with a positive experience.

We finance your entire solution. Unlike others, we allow you to bundle everything you need from hardware and software to service contracts, installation costs, training fees, and sales tax. If you decide weeks or months later to add to your solution, we can consolidate everything into a single invoice.

Our Premier Client services provide large accounts with special handling services to ensure these complex transactions are serviced properly. As a premier client, you have a dedicated finance specialist who manages your account through its life, from first invoice through asset return or purchase. This specialist develops an in-depth understanding of your invoice and payment requirements. For you, this dedication provides a high-quality, easy, and positive financing experience.

For your region specific offers please ask your Lenovo sales representative or your technology provider about the use of Lenovo Financial Services. For more information, see the following Lenovo website:

https://www.lenovo.com/us/en/landingpage/lenovo-financial-services/

Related product families

Product families related to this document are the following:

Trademarks

 

Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.

The following terms are trademarks of Lenovo in the United States, other countries, or both:
AnyBay®
Bootable Media Creator
Flex System
Lenovo Services
Lenovo®
RackSwitch
ServerProven®
System x®
ThinkServer®
ThinkSystem
TopSeller
TruDDR4
UpdateXpress System Packs
XClarity®

The following terms are trademarks of other companies:

Intel®, Optane™, and Xeon® are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

Linux® is the trademark of Linus Torvalds in the U.S. and other countries.

ActiveX®, Hyper-V®, Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.

 

Other company, product, or service names may be trademarks or service marks of others

The Lenovo Server Operating System Interoperability Guide (OSIG) is a comprehensive source of information about operating system compatibility with Lenovo servers. It includes servers in the ThinkSystem, ThinkAgile, System x, ThinkServer, NeXtScale, Flex System and BladeCenter product families and covers servers that are currently supported by Lenovo under warranty.

Learn about the OSIG web interface: view the introductory video and read the article.

To begin: Enter a search term or select entries from the pull-down menus.

 

Abstract

The Lenovo zero-U (0U) Switched and Monitored power distribution units (PDUs) are the ideal solutions when you need flexible, reliable, easy-to-deploy power distribution with branch circuit protection to minimize downtime. These rack-dense units distribute power to up to 42 outlets. The 0U PDUs are designed to be installed vertically in the rear channel or side pockets of a Lenovo rack, thereby not consuming any horizontal rack space.

This product guide provides essential presales information to understand the 0U Switched and Monitored PDUs and their key features, specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about the Switched and Monitored PDUs and consider their use in IT solutions.

Change History

Changes in the April 2 update:

Introduction

The Lenovo zero-U (0U) Switched and Monitored power distribution units (PDUs) are the ideal solutions when you need flexible, reliable, easy-to-deploy power distribution with branch circuit protection to minimize downtime. These rack-dense units distribute power to up to 42 outlets. 0U PDUs are designed to be installed vertically in the rear channel or side pockets of a Lenovo rack, thereby not consuming any horizontal rack space that otherwise be used by servers, storage and network switches (hence the term 0U).

The following figure displays the 0U Switched and Monitored PDUs.

Lenovo 0U Switched and Monitored PDUs
Figure 1. Lenovo 0U Switched and Monitored PDUs

Did you know?

With ever growing power densities in today’s rack environments, it is all too easy to add load in the wrong place and trigger an overload event. The 0U Switched and Monitored PDU offerings can minimize this impact, providing the ability to quickly recover with resettable circuit breakers for each designated bank of receptacles, referred to as load groups. Breakers are color coded to the receptacles in a particular load group to aid in configuration, installation, and maintenance. Furthermore, these PDUs also offer individual outlet remote monitoring and switching (on/off), which allows for remote power sequencing and further helping to prevent unintended PDU overloading.

Introduction to PDUs

A power distribution unit (PDU) is a highly reliable, multiple outlet power strip designed to consolidate line cords within the rack and distribute conditioned power from an uninterruptible power supply (UPS) or utility power to servers and other IT equipment. The PDU efficiently distributes power within the rack and provides fault-tolerant power redundancy for high availability requirements.

There are three types of PDUs available from Lenovo: basic, monitored, and switched & monitored. The PDUs covered in this document are of the switched & monitored type.

Part number information

The following table provides the ordering part numbers and feature codes for the 0U Switched and Monitored PDUs.

Table 1. Ordering part numbers and feature codes
Part
number
Feature
code
Description Region
availability*
00YJ780 AU01 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU International
00YJ781 AU03 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU (30A derated) North America
00YJ782 AU02 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU International
00YJ783 AU04 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU (60A derated) North America
46M4113 6146 Enviromental Monitoring Probe All countries

* See region availability below

Region availability

PDUs indicated in Table 1 as available for North America are available in the following countries:

  • United States
  • Canada
  • Mexico
  • Saudi Arabia
  • Japan
  • Philippines
  • Some of Brazil

PDUs indicated in Table 1 as available Internationally are available in these regions:

  • Europe
  • Africa
  • Most of the Middle East
  • Most of Asia
  • Australia/New Zealand
  • Most of South America

Included with the PDUs

The PDUs include the following items:

Features and specifications

The 0U Basic PDUs have the following common features:

The following table compares the technical and environmental specifications of the 0U Switched and Monitored PDUs.

Table 2. PDU specifications
Feature 0U 20 C13/4 C19 Switched and Monitored 32A 1 Phase PDU 0U 20 C13/4 C19 Switched and Monitored 24A 1 Phase PDU 0U 18 C13/6 C19 Switched and Monitored 32A 3 Phase PDU 0U 12 C13/12 C19 Switched and Monitored 48A 3 Phase PDU
Part Number 00YJ780 00YJ781 00YJ782 00YJ783
Feature Code AU01 AU03 AU02 AU04
Region International North America International North America
Input power
Number of phases Single phase input Three phase input
Line cord Attached line cord, 3 m length (9-ft, 10-in)
Line cord connector 332P6, W+N+PE 1ph NEMA L6-30P 532P6, WYE, 3W+N+PE 3Ph HBL460P9, Delta 3W+PE 3ph
Plug design
Input voltage 200-240V 200-240V 200-240V /
350-415V
200-240V
Input current 32A 24A (derated from 30A) 32A 48A (derated from 60A)
Maximum power rating 7680 VA 5760 VA 23,040 VA 20,736 VA
Output power
Number of C13 outlets 20 20 18 12
Number of C19 outlets 4 4 6 15
Output voltage rating at 50/60Hz 200-240V 200-240V 200-240V 200-240V
Output current rating Each C13 outlet: 10 amps; Each C19 outlet: 16 amps
Circuit breakers Two double-pole branch rated circuit breakers rated at 16A Six double-pole branch rated circuit breakers rated at 16A
Number of load groups 2 (A, B) 2 (A, B) 6 (A-F) 6 (A-F)
Number of outlets per load group A = 10x C13, 2x C19
B = 10x C13, 2x C19
A = 10x C13, 2x C19
B = 10x C13, 2x C19
A = 3x C13, 1x C19
B = 3x C13, 1x C19
C = 3x C13, 1x C19
D = 3x C13, 1x C19
E = 3x C13, 1x C19
F = 3x C13, 1x C19
A = 2x C13, 2x C19
B = 2x C13, 2x C19
C = 2x C13, 2x C19
D = 2x C13, 2x C19
E = 2x C13, 2x C19
F = 2x C13, 2x C19
Capacity per load group (Amps) A = 16 A
B = 16 A
A = 20 A
B = 20 A
A = 20 A
B = 20 A
C = 20 A
D = 16 A
E = 16 A
F = 16 A
A = 20 A
B = 20 A
C = 20 A
D = 20 A
E = 20 A
F = 20 A
Capacity per phase (Amps) Not applicable Not applicable 32 A 32 A
Capacity per PDU (Amps) 32 A 24 A 96 A 86 A
Mechanical and environmental
Physical dimensions (DxWxH) 2.5 x 2.0 x 66.4 in
66 x 52 x 1689 mm
2.5 x 2.0 x 66.4 in
66 x 52 x 1689 mm
3.9 x 2.0 x 66.4 in
100 x 52 x 1689 mm
5.1 x 2.0 x 66.4 in
131 x 52 x 1689 mm
Weight 5 kg / 11 lb 5.1 kg / 11.2 lb 6.9 kg / 15.2 lb 10.5 kg / 23.1 lb
Operating temperature 10° C to 60° C
50° F to 140° F
10° C to 55° C
50° F - 122° F
10° C to 60° C
50° F to 140° F
10° C to 55° C
50° F - 122° F
Operating humidity 5% to 95% without condensation

Connectors and load groups

The 0U Switched and Monitored PDUs with 20 C13 connectors and 4 C19 connectors (part numbers
00YJ780 and 00YJ781) have the components and controls as shown in the following figure.

Load groups for 00YJ780 and 00YJ781
Figure 2. Load groups for part numbers 00YJ780 and 00YJ781

The 0U Switched and Monitored PDU with 18 C13 connectors and 6 C19 connectors (part number 00YJ782) has the components and controls as shown in the following figure.

Load groups for part number 00YJ782
Figure 3. Load groups for part number 00YJ782

The 0U Switched and Monitored PDU with 12 C13 connectors and 12 C19 connectors (part number
00YJ783) has the components and controls as shown in the following figure.

Load groups for part number 00YJ783
Figure 4. Load groups for part number 00YJ783

Management interface

The switched and managed PDUs include Network Management Module (NMM) that provides the interface and connectors to manage the PDU. The following figure shows the LCD screen and the ports of the NMM. The LCD interface provides information about the load status, events, measurements, identification, and settings.

NMC connectors
Figure 5. Interface of the Network Management Module

The components of the NMM are as follows:

Daisy chain example
Figure 6. Daisy chaining example

Environmental Monitoring Probe

The Environmental Monitoring Probe (EMP), part number 46M4113, is an optional device used to report local temperature and humidity values at its installed location and make that information available to the web interface of the PDU. The EMP connects to the PDU via the EMP/Serial port of the NMM that is installed in the PDU. The following figure displays the EMP.

Environmental Monitoring Probe (EMP)
Figure 7. Environmental Monitoring Probe

The Environmental Monitoring Probe has the following features:

Browser interface

The PDU provides a graphical user interface that you can view from a web browser. Using a web browser, you can access and monitor the PDU power outlets and output devices remotely from a computer.

The following tasks can be performed though browser interface:

Selecting the right PDU

To avoid over sizing or under sizing power, it is important to understand the power requirements of the hardware that will be powered by the PDU(s). To understand this, use the Power Configurator tool to determine the hardware’s overall power usage. Download the Power Configurator from http://support.lenovo.com/au/en/documents/LNVO-PWRCONF.

Likewise, to avoid over sizing or under sizing PDUs it is also important to understand the PDU capabilities and capacities.

Consider the following for capabilities:

Consider the following for capacities:

For additional information on selecting the right PDU, load groups, phases, outlets, line cords, plugs and specifications, see the Lenovo PDU Technical Reference (International or North American version), available from: http://support.lenovo.com/documents/lnvo-powinf

Supported rack cabinets

The 0U Switched and Monitored PDUs can be installed in the following racks:

Each PDU has a universal mounting bracket that enables the PDU to be mounted in a variety of different racks that are outside of the Lenovo portfolio.

The PDU is designed to be mounted without the use of tools. Mounting buttons are pre-installed on the rear of the PDU at the factory. The mounting buttons allow for three mounting methods for installing the 0U Switched and Monitored PDUs vertically in a rack.

For additional information on racking the 0U Switched and Monitored PDUs, refer to User’s Guide for the PDUs.

Warranty

The 0U Switched and Monitored PDUs are offered with a three-year limited warranty. At Lenovo discretion this warranty will be either CRU service (customer replaceable unit) or a Lenovo employee, subcontractor or reseller will be assigned to repair the failing item. Proof and date of purchase is required for warranty claims.

Agency approvals

The PDUs conform to the following standards:

Abstract

The Lenovo zero-U (0U) Basic power distribution units (PDUs) are the ideal solutions when you need flexible, reliable, easy-to-deploy power distribution with branch circuit protection to minimize downtime. These rack-dense units distribute power to up to 42 outlets. The 0U PDUs are designed to be installed vertically in the rear channel or side pockets of a Lenovo rack, thereby not consuming any horizontal rack space.

This product guide provides essential presales information to understand the 0U Basic PDUs and their key features, specifications, and compatibility. This guide is intended for technical specialists, sales specialists, sales engineers, IT architects, and other IT professionals who want to learn more about 0U Basic PDUs and consider their use in IT solutions.

Change History

Changes in the April 2 update:

Introduction

The Lenovo zero-U (0U) Basic power distribution units (PDUs) are the ideal solutions when you need flexible, reliable, easy-to-deploy power distribution with branch circuit protection to minimize downtime. These rack-dense units distribute power to up to 42 outlets. The 0U PDUs are designed to be installed vertically in the rear channel or side pockets of a Lenovo rack, thereby not consuming any horizontal rack space that otherwise be used by servers, storage and network switches (hence the term 0U).

The following figure displays the 0U Basic PDUs.

Lenovo 0U Basic PDUs
Figure 1. Lenovo 0U Basic PDUs

Did you know?

With ever growing power densities in today’s rack environments, it is all too easy to add load in the wrong place and trigger an overload event. The 0U Basic PDU offerings can minimize this impact, providing the ability to quickly recover with resettable circuit breakers for each designated bank of receptacles, referred to as load groups. Breakers are color coded to the receptacles in a particular load group to aid in configuration, installation, and maintenance.

Introduction to PDUs

A power distribution unit (PDU) is a highly reliable, multiple outlet power strip designed to consolidate line cords within the rack and distribute conditioned power from an uninterruptible power supply (UPS) or utility power to servers and other IT equipment. The PDU efficiently distributes power within the rack and provides fault-tolerant power redundancy for high availability requirements.

There are three types of PDUs available from Lenovo: basic, monitored, and switched & monitored. The PDUs covered in this document are of the basic type.

Part number information

The following table provides the ordering part numbers and feature codes for the 0U Basic PDUs.

Table 1. Ordering part numbers and feature codes
Part
number
Feature
code
Description Region
availability*
00YJ776 ATZY 0U 36 C13/6 C19 24A 1 Phase PDU (30A derated) North America
00YJ777 ATZZ 0U 36 C13/6 C19 32A 1 Phase PDU International
00YJ778 AU00 0U 21 C13/12 C19 32A 3 Phase PDU International
00YJ779 ATZX 0U 21 C13/12 C19 48A 3 Phase PDU (60A derated) North America

* See region availability below

Region availability

PDUs indicated in Table 1 as available for North America are available in the following countries:

PDUs indicated in Table 1 as available Internationally are available in these regions:

Included with the PDUs

The PDUs include the following items:

Features and specifications

The 0U Basic PDUs have the following common features:

The following table compares the technical and environmental specifications of the 0U Basic PDUs.

Table 2. PDU specifications
Feature 0U 36 C13/6 C19 30A 1 Phase PDU 0U 36 C13/6 C19 32A 1 Phase PDU 0U 21 C13/12 C19 32A 3 Phase PDU 0U 21 C13/12 C19 60A 3 Phase PDU
Part Number 00YJ776 00YJ777 00YJ778 00YJ779
Feature Code ATZY ATZZ AU00 ATZX
Region North America International International North America
Input power
Number of phases Single phase input Three phase input
Line cord Attached line cord, 3 m length (9-ft, 10-in)
Line cord connector NEMA L6-30P 332P6, W+N+PE 1ph 532P6, WYE, 3W+N+PE 3Ph HBL460P9, Delta 3W+PE 3ph
Plug design
Input voltage 200-240V 200-240V 200-240V / 350-415V 200-240V
Input current 24A (derated from 30A) 32A 32A 48A (derated from 60A)
Maximum power rating 5760 VA 7680 VA 23,040 VA 20,736 VA
Output power
Number of C13 outlets 36 36 21 21
Number of C19 outlets 6 6 12 12
Output voltage rating at 50/60Hz 200-240V 200-240V 200-240V 200-240V
Output current rating Each C13 outlet: 10 amps; Each C19 outlet: 16 amps
Circuit breakers Two double-pole branch rated circuit breakers rated at 16A Six double-pole branch rated circuit breakers rated at 16A
Number of load groups 2 (A, B) 2 (A, B) 6 (A-F) 6 (A-F)
Number of outlets per load group A = 18x C13, 3x C19
B = 18x C13, 3x C19
A = 18x C13, 3x C19
B = 18x C13, 3x C19
A = 4x C13, 2x C19
B = 4x C13, 2x C19
C = 4x C13, 2x C19
D = 3x C13, 2x C19
E = 3x C13, 2x C19
F = 3x C13, 2x C19
A = 4x C13, 2x C19
B = 4x C13, 2x C19
C = 4x C13, 2x C19
D = 3x C13, 2x C19
E = 3x C13, 2x C19
F = 3x C13, 2x C19
Capacity per load group (Amps) A = 20 A
B = 20 A
A = 16 A
B = 16 A
A = 20 A
B = 20 A
C = 20 A
D = 16 A
E = 16 A
F = 16 A
A = 20 A
B = 20 A
C = 20 A
D = 20 A
E = 20 A
F = 20 A
Capacity per phase (Amps) Not applicable Not applicable Phase 1:
A + D = 32 A
Phase 2:
B + E = 32 A
Phase 3:
C + F = 32 A
Phase 1:
A + D = 32 A
Phase 2:
B + E = 32 A
Phase 3:
C + F = 32 A
Capacity per PDU (Amps) 24 A 32 A 96 A 86 A
Mechanical and environmental
Physical dimensions (DxWxH) 2.5 x 2.0 x 66.4 in
66 x 52 x 1689 mm
2.5 x 2.0 x 66.4 in
66 x 52 x 1689 mm
3.0 x 2.0 x 66.4 in
77 x 52 x 1689 mm
3.8 x 2.0 x 66.4 in
99 x 52 x 1689 mm
Weight 4 kg / 8.8 lb. 4 kg / 8.8 lb. 5.3 kg / 11.6 lb. 8.7 kg / 19.1 lb.
Operating temperature 10° C to 55° C
50° F - 122° F
10° C to 60° C
50° F to 140° F
10° C to 60° C
50° F to 140° F
10° C to 55° C
50° F - 122° F
Operating humidity 5% to 95% without condensation

Connectors and load groups

The 0U Basic PDUs with 36 C13 connectors and 6 C19 connectors (part numbers 00YJ776 and
00YJ777) have the components and controls as shown in the following figure.

Load groups for 00YJ776 and 00YJ777
Figure 2. Load groups for part numbers 00YJ776 and 00YJ777

The 0U Basic PDUs with 21 C13 connectors and 12 C19 connectors (part numbers 00YJ778 and 00YJ779) have the components and controls as shown in the following figure.

Load groups for part numbers 00YJ778 and 00YJ779
Figure 3. Load groups for part numbers 00YJ778 and 00YJ779

Selecting the right PDU

To avoid over sizing or under sizing power, it is important to understand the power requirements of the hardware that will be powered by the PDU(s). To understand this, use the Power Configurator tool to determine the hardware’s overall power usage. Download the Power Configurator from the following link: http://support.lenovo.com/au/en/documents/LNVO-PWRCONF

Likewise, to avoid over sizing or under sizing PDUs it is also important to understand the PDU capabilities and capacities.

Consider the following for capabilities:

Consider the following for capacities:

For additional information on selecting the right PDU, load groups, phases, outlets, line cords, plugs and specifications, see the Lenovo PDU Technical Reference (International or North American version), available from: http://support.lenovo.com/documents/lnvo-powinf

Supported rack cabinets

The 0U Basic PDUs can be installed in the following racks:

Each PDU has a universal mounting bracket that enables the PDU to be mounted in a variety of different racks that are outside of the Lenovo portfolio.

The PDU is designed to be mounted without the use of tools. Mounting buttons are pre-installed on the rear of the PDU at the factory. The mounting buttons allow for three mounting methods for installing the 0U Basic PDUs vertically in a rack.

For additional information on racking the 0U Basic PDUs, refer to User’s Guide for the PDUs.

Warranty

The 0U Basic PDUs are offered with a three-year limited warranty. At Lenovo discretion this warranty will be either CRU service (customer replaceable unit) or a Lenovo employee, subcontractor or reseller will be assigned to repair the failing item. Proof and date of purchase is required for warranty claims.

Agency approvals

The PDUs conform to the following standards:

Related product families

Product families related to this document are the following: