Dell™ PowerVault NX3300 Manuel du propriétaire -> Accéder au site Dell -> Accéder aux Codes Promo et Bons de réduction Dell -> Voir d'autres manuels Dell Revenir à l'accueil

ou juste avant la balise de fermeture -->

 

 

 

Accéder au Support :

http://support.dell.com/support/edocs/stor-sys/NX3300/fr/omfr.pdf

-> Commander sur Dell.com, Cliquez ici

 

Autres manuels :

Dell

Dell-Imprimantes-laser-Dell-2350d-et-Dell-2350dn

Dell-XPS-430-Guide-de-reference-rapide

Dell-PowerEdge-RAID-Controller-PERC-H700-et-H800-Guide-d-utilisation

Dell-Lifecycle-Controller-2-Version-1.00.00-User-s-Guide

Dell-OpenManage-Server-Administrator-Version-7.0-Guide-d-utilisation

Dell-Solutions-NAS-Dell-FluidFS-Manuel-du-proprietaire-Manue

Dell-Guide-de-l-utilisateur-Dell-V525w

Dell-XPS-13-Manuel-du-proprietaire

Dell-Adaptateurs-Brocade-Manuel-d-installation-et-de-reference

Dell-FluidFS-NAS-Solutions-NX3600-NX3610-Guide-de-deploiement

Dell-Systemes-Dell-PowerEdge-T410-Manuel-du-proprietaire

Dell-Latitude-ST-Manuel-du-proprietaire-Manuel

Dell-OptiPlex-360-Guide-de-configuration-et-de-reference-rapide

Dell-PowerEdge-R810-Manuel-du-proprietaire-du-materiel

Dell-Guide-d-installation-des-systemes-Dell-PowerVault-Modular-Disk-3000

Dell-Imprimante-laser-Dell-2230d-Guide-de-l-utilisateur

Dell-Systemes-Dell-PowerEdge-C6105-Manuel-du-proprietaire-du-materiel

Dell-Imprimante-personnelle-a-jet-d-encre-Dell-J740-Manuel-du-proprietaire

Dell-2130cn-IMPRIMANTE-LASER-COULEUR

Dell-Guide-d-utilisation-de-la-station-de-travail-Dell-Precision-T3400

Dell-1235cn-Imprimante-Multifonction-Mode-d-emploi

Dell-Vostro-1310-1510-1710-et-2510-Guide-de-configuration-et-de-reference-rapide

Dell-Guide-d-utilisation-APC-Smart-UPS-750VA-1000VA-1500VA-100-120-230-V-CA-2U-Montage-en-baie-Onduleur

Dell-Guide-d-utilisation-Modele-TL24iSCSIxSAS%201Gb-iSCSI-a-SAS

Dell-Imprimantes-laser-Dell-1130-et-Dell-1130n

Dell-Precision-M6400-Guide-de-configuration-et-de-reference-rapide

Dell-M770mm-Color-Monitor-Quick-Set-up

Dell-Carte-de-gestion-reseau-AP9617-AP9618-AP9619-Manuel-d-installation-et-de-demarrage-rapide

Dell-Projecteur-Dell-1410X-Guide-d-utilisation

Dell-Imprimante-couleur-Dell-1350cnw

Dell-Manuel-d-utilisation-Dell-Inspiron-M5040-15-N5040-15-N5050-Manuel

Dell-Manuel-de-maintenance-Dell-Inspiron-620

Dell-3D-VISION-MANUEL-D-UTILISATION

Dell-Inspiron-600m-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R805-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R900-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-2970-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-C6145-Manuel-du-proprietaire-du-materiel

Dell-Inspiron-660s-Manuel-du-proprietaire

Dell-P513w-User-s-Guide-Francais-manuel

Dell-Inspiron-660-manuels

Dell-Serveur-de-sauvegarde-sur-disque-Dell-PowerVault-DL-optimise-par-CommVault-Simpana-Guide-d-utilisation

Dell-P513w-User-s-Guide-Guide-de-l-utilisateur-manuel

Dell-Precision-Workstation-T1650-Manuel-du-proprietaire

Dell-ALIENWARE-M17x-MANUEL-DE-L-ORDINATEUR-PORTABLE

Dell-Manuel-du-proprietaire-de-Dell-PowerEdge-M905-M805-M600-et-M605

Dell-Inspiron-One-2330-Manuel-du-proprietaire

Dell-Dimension-1100-B110-Manuel-du-proprietaire

Dell-Vostro-270-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T320-Manuel-du-proprietaire

Dell-Station-de-travail-mobile-Dell-Precision-M4700-Manuel-du-proprietaire

Dell-XPS-8500-Manuel-du-proprietaire

Dell-1230c-Imprimante-laser-couleur-mode-d-emploi-Manuel

Dell-Client-Management-Manuel

Dell-Studio-XPS-Setup-Guide-Manue

Dell-Adaptateur-hote-Dell-PCIe-SCSI-Ultra320-monocanal-Guide-d-utilisation-Manuel

Dell-INSPIRON-DUO-SETUP-GUIDE-Manuel

Dell-INSPIRON-DUO-GUIDE-DE-CONFIGURATION-Manuel

Dell-Guide-de-l-utilisateur-Dell-Inspiron-M4040-14-N4050-Manuel

Dell-Guide-de-l-administrateur-de-Dell-PowerVault-705N-Manuel

Dell-Vostro-420-220-220s-Guide-de-Configuration-et-de-Reference-Rapide-Manuel

Dell-Matrices-de-stockage-Dell-PowerVault-MD3660f-Series-Guide-de-deploiement-Manuel

Dell-Systemes-Dell-PowerVault-Network-Attached-Storage-NAS-Guide-de-l-administrateur-Manuel

Dell-Latitude-D430-Guide-d-utilisation-Manuel

Dell-Studio-XPS-Guide-de-configuration-Manuel

Dell-PowerEdge-C410x-Manuel-du-proprietaire

Dell-Precision-Workstation-T1650-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R300-Manuel-du-proprietaire

Dell-Systemes%20-Dell%20PowerEdge-T110-II-Manuel-du-proprietaire

Dell-Vostro-200-Manuel-du-proprietaire-Mini-Tower

Dell-Inspiron-531-Manuel-du-proprietaire

Dell-ALIENWARE-MANUEL-DE-L-ORDINATEUR-DE-BUREAU-Francais

Dell-PowerEdge-R520-Manuel-du-proprietaire

Projecteur-Dell-1201MP-Manuel-d-utilisation

Dell-PowerEdge-R910-Manuel-du-proprietaire

Dell-Dimension-C521-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T605-Manuel-du-proprietaire

Dell-Mobile-Jamz

Dell-Inspiron-530-Series-Manuel-du-proprietaire

Dell-Vostro-3460-Manuels

Dell-OPENMANAGE-POWER-CENTER-1.1-Guide-d-utilisation

Dell-PowerVault-MD3660f-Storage-Arrays-Manuels

Dell™ Ekran Yöneticisi Kullanıcı Kılavuzu

Dell-PowerEdge-R620-Guide-de-mise-en-route

Dell-PowerEdge-R520-Guide-de-mise-en-route

DELL-POWERVAULT-MD1200-et-MD1220-TECHNICAL-GUIDEBOOK

Console-de-gestion-multi-onduleurs-Dell-Manuel-de-l-utilisateur-pour-l-installation-et-la-configuration

DELL-OPTIPLEX580-TECHNICAL-GUIDEBOOK-INSIDE-THE-OPTIPLEX-580

Dell-Inspiron-1720-manuels

Dell-PowerEdge-R720-et-R720xd-Guide-de-mise-en-route

Dell-Vostro-1540-1550-Manuel-du-proprietaire

Dell-Latitude-E5430-Manuel-du-proprietaire

Dell™ S2240L/S2340L Monitör Kullanıcı Kılavuzu

Dell PowerEdge Sistemleri İçin Microsoft Windows Server 2012 Önemli Bilgiler Kılavuzu

Dell-Guide-de-l-utilisateur-du-moniteur-Dell-S2240L-S2340L

Dell™ S320/S320wi Projektör Kullanım Kılavuzu

Dell-%20Vostro-270-Manuels

Dell-Vostro-3460-Manuel-du-proprietaire-Francais

Dell-Inspiron-9200-Manuel-de-l-utilisateur

Dell-Inspiron-2600-et-2650-Manuel-de-l-utilisateur

Dell-Axim-X30-Manuel-de-l-utilisateur

Dell-Vostro-2520-Manuel-du-proprietaire

Dell-Inspiron-1721-Manuel

Dell-Systemes-Dell-PowerEdge-T710-Manuel-du-proprietaire

Dell-Precision-Workstation-T5600-Manuel-du-proprietaire

Dell-Solutions-NAS-Dell-FluidFS-Manuel-du-proprietaire

Systemes-Dell-PowerEdge-C5220-Manuel-du-proprietaire-du-materiel

Dell-Dimension-3000-Manuel-du-proprietaire

Dell-PowerEdge-R210-Technical-Guide

Dell-Inspiron-Manuels

Dell-Manuel-du-proprietaire-du-Dell-Vostro-1700

Dell-Clavier-sans-fil-et-souris-Dell-KM713-Manuel-de-l'utilisateur

Dell-Systeme-de-navigation-GPS-Dell-Manuel-de-l'utilisateur

Dell-Logiciel-de-gestion-de-l-onduleur-Manuel-de-l-utilisateur-pour-l-installation-et-la-configuration

Dell-Demarrage-rapide-du-moniteur-couleur-M990

Dell-Manuel-de-l-utilisateur-de-la-station-de-travail-Dell-Precision-370

Dell-Systemes-Dell-PowerEdge-2800-Guide-d-installation-et-de-depannage

Dell-Manuel-de-l-utilisateur-du-systeme-Dell-OptiPlex-SX280

Dell-Vostro-1440-1450-Manuel-de-l-utilisateur

Dell-Photo-Printer-540-Guide-de-l-utilisateur

Dell-Streak-7-Francais-Manuel-de-l-utilisateur

Dell-Venue-Pro-Manuel-de-l-utilisateur

Dell-Imprimante-laser-personnelle-Dell-P1500-Manuel-du-proprietaire

Dell-PowerEdge-C5125-Manuel-du-proprietaire-du-materiel

Dell-Latitude-D630-Manuels

Dell-Vostro-400-Manuel-du-proprietaire-Mini-Tower

Dell-Systemes-Dell-PowerEdge-T100-Manuel-du-proprietaire

Dell-OptiPlex-9010-7010-compact-Manuel-du-proprietaire

Dell-PowerVault%20NX3200-Manuel-du-proprietaire

Dell-Inspiron-1200-et-2200-Manuel-de%20l-utilisateur

Dell-Vostro-1540-1550-Manuel-du-proprietaire

Dell-Inspiron-8600-Manuel-du-proprietaire

Dell-PowerVault-Baie-de-stockage-MD1120-Manuel-du-proprietaire

Dell-Dimension-E521-Manuel-du-proprietaire

Dell-Inspiron-9100-Manuel-du-proprietaire

Dell-Vostro-3360-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T300-Manuel-du-proprietaire

Dell-XPS-One-2710-manuel-d-utilisation

Dell-Inspiron-1150-Manuel-du-proprietaire

Dell-Latitude-E5530-Manuel-du-proprietaire

Dell-Inspiron-660-Manuel-du-proprietaire

Acceder-au-site-Dell

Dell-Manuel-du-proprietaire-des-Dell-Latitude-E6420-et-E6420-ATG-Francais

Dell-OptiPlex-9010-Tout-en-un-Manuel-du-proprietaire

Dell-Vostro-3560-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T110-Manuel-du-proprietaire

Dell-server-poweredge-m710-tech-guidebook_fr

Dell-Systemes-Dell-PowerEdge-R420-Manuel-du-proprietaire

Dell-Latitude-5420-E5420-E5420m-Manuel-de-l-utilisateur

Dell-Latitude-E6320-Manuel-de-l-utilisateur

Dell-Systemes-Dell-Inspiron-8200-Manuel-de-l-utilisateur-Francais

Dell-server-poweredge-r610-tech-guidebook_fr

Dell-server-poweredge-t710-technical-guide-book_fr

Dell-server-poweredge-m1000e-tech-guidebook_fr

Dell-server-poweredge-m610-tech-guidebook_fr

Dell-poweredge-r210-technical-guidebook-en_fr

Dell-MANUEL-ALIENWARE-M15x-MOBILE-Manuel-de-l-utilisateur

Dell-Axim-X51-X51v-Manuel-de-l-utilisateur

Dell-Beats-By-dr.dre-Manuel-et-Garantie

Dell-Dimension-3100C-Manuel-du-proprietaire

 

Dell-Precision-Workstation-T3600-Manuel-du-proprietaire

Dell-Vostro-200-Manuel-du-proprietaire-Slim-Tower

Dell-ALIENWARE-MANUEL-DE-L-ORDINATEUR-DE-BUREAU

Dell-OPENMANAGE-POWER-CENTER-1-1-Guide-d-utilisation

Dell-Vostro-360-Proprietaire-du-manuel

Dell-Dimension-3100C-Manuel-du-proprietaire

AlienwareArea-51Area-51ALX

Dell-Ordinateurs-de-Bureau-PC-Portables-Netbooks/AlienwareAurora-R3

AlienwareAurora-R4

lienwareAuroraAuroraALXAurora-R2

Chassis-RAID-Dell-PowerVault-MD3000i-Manuel-du-proprietaire

Dell-Axim-X50-Manuel-du-proprietaire

Dell-Axim-X51-X51v-Manuel-du-proprietaire

Dell-Baie-de-stockage-Dell-PowerVault-MD1000-Manuel-du-proprietaire

Dell-Boîtier-Dell-PowerEdge-M1000e-Manuel-du-proprietaire

Dell-Clavier-Axim-Manuel-du-proprietaire

Dell-Dimension-3100-E310-Manuel-du-proprietaire

Dell-Dimension-9200-Manuel-du-proprietaire

Dell-Dimension-E520-Manuel-du-proprietaire

Dell-Imprimante-laser-Dell-1100-Manuel-du-proprietaire

Dell-Imprimante-laser-de-groupe-de-travail-Dell-M5200-Manuel-du-proprietaire

Dell-Imprimante-laser-monochrome-Dell-5330dn-Mode-d-emploi

Dell-Imprimante-laser-multifonction-Dell-1600n-Manuel-du-proprietaire

Dell-Inspiron-13z-Manuel-du-proprietaire

Dell-Inspiron-17R-Manuel-du-proprietaire

Dell-Inspiron-530s-Manuel-d-utilisation

Dell-Inspiron-530s-Manuel-du-proprietaire

Dell-Inspiron-700m-Manuel-du-proprietaire

Dell-Inspiron-1100-Manuel-d-utilisation

Dell-Inspiron-1525-1526-Manuel-du-proprietaire

Dell-Inspiron-5100-et-5150-Manuel-d-utilisation

Dell-Inspiron-9300-Manuel-du-proprietaire

Dell-Inspiron-9400-E1705-Manuel-du-proprietaire

http://www.audentia-gestion.fr/Dell-Ordinateurs-de-Bureau-PC-Portables-Netbooks/Dell-Laser-Printer-1700-1700n-Manuel-du-proprietaire.htm

Dell-Laser-Printer-1710-1710n-Manuel-du-proprietaire

Dell-Laser-Printer-3100cn-manuel-du-proprietaire

Dell-Latitude-ST-Manuel-du-proprietaire

Dell-Latitude-XT3-Manuel-du-proprietaire

Dell-Liste-des-manuels-et-de-la-documentation-Dell

Dell-MANUEL-ALIENWARE-M11x-MOBILE-Manuel-du-proprietaire

Dell-MANUEL-ALIENWARE-M15x-MOBILE

Dell-MANUEL-D-ALIENWARE-M17x-MOBILE-francais

Dell-MANUEL-D-ALIENWARE-M17x-MOBILE

Dell-Manuel-d-utilisation-Dell-Inspiron-M5040-15-N5040-15-N5050

Dell-Manuel-d-utilisation-du-Dell-XPS-420

Dell-Manuel-de-l-Utilisateur-Dell-Latitude-E6220

Dell-Manuel-de-l-Utilisateur-Dell-Latitude-E6520

Dell-Manuel-de-l-utilisateur-Dell-Latitude-E6320

Dell-Manuel-de-maintenance-Dell-Inspiron-N5110

Dell-Manuel-du-proprietaire-Dell-Vostro-1500

Dell-Manuel-du-proprietaire-Dell-XPS-M1330

Dell-Manuel-du-proprietaire-des-Dell-Latitude-E6420-et-E6420-ATG

Dell-Manuel-du-proprietaire-du-Dell-Inspiron-1721

Dell-Manuel-du-proprietaire-du-Dell-XPS-M1730

Dell-Manuel-du-proprietaire-du-Dell-XPS-One

Dell-Matrices-de-stockage-Dell-PowerVault-MD3260i-Series-Guide-de-deploiement

Dell-Matrices-de-stockage-Dell-PowerVault-MD3660i-Series-Guide-de-deploiement

Dell-Photo-All-In-One-Printer-944-Manuel-du-proprietaire

Dell-Photo-All-In-One-Printer-964-Manuel-du-proprietaire

Dell-Photo-All-In-One-Printer%20942-Manuel-du-proprietaire

Dell-Photo-Printer-720-Manuel-du-proprietaire

Dell-PowerEdge-C8220-Manuel-du-proprietaire

Dell-PowerEdge-R620-Manuel-du-proprietaire

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Guide-de-l-administrateur

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Manuel-du-proprietaire

Dell-PowerVault-NX400-Guide-de-mise-en-route

Dell-Precision-Workstation-T7600-Manuel-du-proprietaire

Dell-Streak-7-Manuel-de-l-utilisateur

Dell-Streak-Manuel-d-utilisation

Dell-Systemes-Dell-Inspiron-4150-Manuel-de-l-utilisateur

Dell-Systemes-Dell-Inspiron-8200-Manuel-de-l-utilisateur

Dell-Systemes-Dell-PowerEdge-1950-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-M420-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R210-II-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R410-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R710-Manuel-du-proprietaire%20-Manuel-d-utilisation

Dell-Systemes-Dell-PowerEdge-T310-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T420-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T620-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerVault-NX400-Manuel-du-proprietaire

Dell-Tout-en-un-Dell-Photo-924-Manuel-du-proprietaire

Dell-Vostro-360-Proprietaire-du-manuel

Dell-Vostro-3750-Manuel-du-proprietaire

Dell-Vostro-V131-Manuel-du-proprietaire

Dell-XP-M1530-Manuel-du-proprietaire

Dell-XPS-630i-Manuel-du-proprietair

Dell-moniteur-D1920-Manuel-du-proprietaire

DellDimension1100Series

Imprimante-Dell-Photo-All-In-One-Printer-922-Manuel-du-proprietaire

Imprimante-laser-de-groupe-de-travail-Dell-S2500-Manuel-du-proprietaire

Imprimante-personnelle-Dell-AIO-A960-Manuel-du-proprietaire

alienwareX51

Dell-Manuel-de-l-Utilisateur-Dell-Latitude-E6220

Dell-Systemes-Dell-PowerEdge-T420-Manuel-du-proprietaire

Dell-Systemes-Dell-Inspiron-4150-Manuel-de-l-utilisateur

Dell-Streak-Manuel-d-utilisation

Dell-Manuel-du-proprietaire-du-Dell-XPS-M1730

Dell-Photo-All-In-One-Printer-944-Manuel-du-proprietaire

Dell-Manuel-du-proprietaire-du-Dell-XPS-One

Dell-Clavier-Axim-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R410-Manuel-du-proprietaire

Dell-Manuel-d-utilisation-Dell-Inspiron-M5040-15-N5040-15-N5050

Dell-Manuel-de-maintenance-Dell-Inspiron-N5110

Dell-Inspiron-1100-Manuel-d-utilisation

Dell-Imprimante-laser-de-groupe-de-travail-Dell-M5200-Manuel-du-proprietaire

Dell-Photo-Printer-720-Manuel-du-proprietaire

Dell-Imprimante-laser-Dell-1100-Manuel-du-proprietaire

Dell-Manuel-du-proprietaire-Dell-Vostro-1500

Dell-XP-M1530-Manuel-du-proprietaire

Dell-Inspiron-530s-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R710-Manuel-du-proprietaire-Manuel-d-utilisation

Dell-Inspiron-5100-et-5150-Manuel-d-utilisation

Dell-Manuel-de-l-Utilisateur-Dell-Latitude-E6520

Dell-MANUEL-D-ALIENWARE-M17x-MOBILE

Dell-Manuel-de-l-utilisateur-Dell-Latitude-E6320

Dell-Laser-Printer-3100cn-manuel-du-proprietaire

Dell-Inspiron-530s-Manuel-d-utilisation

Dell-Systemes-Dell-PowerEdge-1950-Manuel-du-proprietaire

Dell-Manuel-du-proprietaire-des-Dell-Latitude-E6420-et-E6420-ATG

Dell-Imprimante-laser-monochrome-Dell-5330dn-Mode-d-emploi

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Guide-de-l-administrateur

Dell-PowerVault-NX400-Guide-de-mise-en-route

Dell-Matrices-de-stockage-Dell-PowerVault-MD3260i-Series-Guide-de-deploiement

Dell-PowerEdge-C8220-Manuel-du-proprietaire

Dell-MANUEL-ALIENWARE-M11x-MOBILE-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-M420-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerVault-NX400-Manuel-du-proprietaire

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Manuel-du-proprietaire

Dell-Matrices-de-stockage-Dell-PowerVault-MD3660i-Series-Guide-de-deploiement

Dell-Laser-Printer-1700-1700n-Manuel-du-proprietaire

Dell-Inspiron-9400-E1705-Manuel-du-proprietaire

Dell-Tout-en-un-Dell-Photo-924-Manuel-du-proprietaire

Dell-Laser-Printer-1710-1710n-Manuel-du-proprietaire

Dell-Dimension-3100-E310-Manuel-du-proprietaire

Dell-Inspiron-1525-1526-Manuel-du-proprietaire

Dell PowerVault NX3300 Manuel du propriétaire Modèle réglementaire: E16S Series Type réglementaire: E16S001Remarques, précautions et avertissements REMARQUE: Une REMARQUE indique des informations importantes qui peuvent vous aider à mieux utiliser l'ordinateur. PRÉCAUTION: Une PRÉCAUTION indique un risque de dommage matériel ou de perte de données et vous indique comment éviter le problème. AVERTISSEMENT: Un AVERTISSEMENT indique un risque d'endommagement du matériel, de blessure corporelle ou de mort. © 2012 Dell Inc. Marques commerciales utilisées dans ce document : Dell™, le logo Dell, Dell Precision™, OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, Compellent™, KACE™, FlexAddress™, Force10™ et Vostro™ sont des marques de Dell Inc. Intel®, Pentium®, Xeon®, Core® et Celeron® sont des marques déposées d'Intel Corporation aux États-Unis et dans d'autres pays. AMD® est une marque déposée, et AMD Opteron™, AMD Phenom™ et AMD Sempron™ sont des marques d'Advanced Micro Devices, Inc. Microsoft®, Windows®, Windows Server®, Internet Explorer®, MS-DOS®, Windows Vista® et Active Directory® sont des marques ou des marques déposées de Microsoft Corporation aux États-Unis et/ou dans d'autres pays. Red Hat® et Red Hat® Enterprise Linux® sont des marques déposées de Red Hat, Inc. aux États-Unis et/ou dans d'autres pays. Novell® et SUSE® sont des marques déposées de Novell Inc. aux États-Unis et dans d'autres pays. Oracle® est une marque déposée d'Oracle Corporation et/ou de ses filiales. Citrix®, Xen®, XenServer® et XenMotion® sont des marques ou des marques déposées de Citrix Systems, Inc. aux États-Unis et/ou dans d'autres pays. VMware®, Virtual SMP®, vMotion®, vCenter® et vSphere® sont des marques ou des marques déposées de VMware, Inc. aux États-Unis ou dans d'autres pays. IBM® est une marque déposée d'International Business Machines Corporation. 2012 - 07 Rev. A00Table des matières Remarques, précautions et avertissements..............................................................................2 Chapitre 1: À propos du système.................................................................................................9 Voyants et fonctions du panneau avant...................................................................................................................9 Fonctionnalités de l'écran LCD...............................................................................................................................10 Écran d'accueil................................................................................................................................................11 Menu Configuration..........................................................................................................................................11 Menu Vue.........................................................................................................................................................12 Voyants de diagnostic............................................................................................................................................12 Codes des voyants des disques durs.....................................................................................................................13 Voyants et caractéristiques du panneau arrière....................................................................................................14 Codes des voyants de carte réseau.......................................................................................................................16 Codes du voyant d'alimentation.............................................................................................................................16 Autres informations utiles.......................................................................................................................................18 Chapitre 2: Utilisation du gestionnaire de configuration du système et d'amorçage......19 Choix du mode d'amorçage du système.................................................................................................................19 Accès à la configuration du système.....................................................................................................................20 Réponse aux messages d'erreur.....................................................................................................................20 Utilisation des touches de navigation de la configuration du système...........................................................20 Options de configuration du système.....................................................................................................................21 Écran principal System Setup (Configuration du système)..............................................................................21 Écran System BIOS (BIOS du système)...........................................................................................................21 Écran System Information (Informations sur le système)................................................................................22 Écran Memory Settings (Paramètres de la mémoire)......................................................................................22 Écran Processor Settings (Paramètres du processeur)..................................................................................23 Écran SATA Settings (Paramètres SATA)........................................................................................................25 Écran Boot Settings (Paramètres d'amorçage)...............................................................................................25 Écran Integrated Devices (Périphériques intégrés)........................................................................................26 Écran Serial Communications (Communications série)...................................................................................27 Écran System Profile Settings (Paramètres du profil du système)..................................................................28 Écran System Security (Sécurité du système).................................................................................................29 Paramètres divers............................................................................................................................................30 Fonctionnalités de mot de passe du système et de mot de passe de configuration..............................................31 Attribution d'un mot de passe système et/ou de configuration.......................................................................31 Suppression ou modification d'un mot de passe système et/ou de configuration existant............................32 Protection du système à l'aide d'un mot de passe système............................................................................33Utilisation du système avec un mot de passe de configuration activé............................................................33 Accès au Gestionnaire d'amorçage UEFI...............................................................................................................33 Utilisation des touches de navigation du Gestionnaire d'amorçage...............................................................34 Écran Boot Manager (Gestionnaire d'amorçage)............................................................................................34 Menu UEFI Boot (Amorçage UEFI)...................................................................................................................35 Gestion intégrée du système..................................................................................................................................35 Utilitaire de configuration iDRAC............................................................................................................................35 Accès à l'utilitaire de configuration iDRAC......................................................................................................36 Chapitre 3: Installation des composants du système.............................................................37 Outils recommandés...............................................................................................................................................37 Cadre avant (en option)..........................................................................................................................................37 Retrait du cadre avant......................................................................................................................................37 Installation du cadre avant...............................................................................................................................38 Ouverture et fermeture du système........................................................................................................................38 Ouverture du système......................................................................................................................................38 Fermeture du système......................................................................................................................................39 À l'intérieur du système..........................................................................................................................................39 Carénage de refroidissement.................................................................................................................................40 Retrait du carénage de refroidissement..........................................................................................................40 Installation du carénage de refroidissement...................................................................................................41 Mémoire système...................................................................................................................................................41 Consignes générales pour l'installation des barrettes de mémoire................................................................43 Consignes spécifiques à chaque mode...........................................................................................................44 Exemples de configurations de mémoire.........................................................................................................45 Retrait de barrettes de mémoire......................................................................................................................48 Installation de barrettes de mémoire...............................................................................................................49 Disques durs...........................................................................................................................................................50 Retrait d'un cache de lecteur de disque dur de 2,5 pouces............................................................................51 Installation d'un cache de lecteur de disque dur de 2,5 pouces.....................................................................51 Retrait d'un disque dur remplaçable à chaud..................................................................................................51 Installation d'un disque dur remplaçable à chaud...........................................................................................52 Retrait d'un disque dur installé dans un support.............................................................................................53 Installation d'un disque dur dans un support...................................................................................................53 Optical Drive (Lecteur optique)...............................................................................................................................54 Retrait du lecteur optique.................................................................................................................................54 Installation du lecteur optique.........................................................................................................................55 Ventilateurs de refroidissement.............................................................................................................................55 Retrait d'un ventilateur.....................................................................................................................................55 Installation d'un ventilateur de refroidissement..............................................................................................56 Clé de mémoire USB interne (en option)................................................................................................................57 Remplacement de la clé USB interne..............................................................................................................57Cartes d'extension et cartes de montage pour cartes d'extension.......................................................................58 Consignes d'installation des cartes d'extension.............................................................................................58 Retrait d'une carte d'extension........................................................................................................................59 Installation d'une carte d'extension.................................................................................................................60 Retrait de cartes de montage de carte d'extension.........................................................................................60 Installation des cartes de montage pour cartes d'extension..........................................................................62 Carte SD vFlash.......................................................................................................................................................62 Remplacement de la carte SD vFlash..............................................................................................................62 Module SD interne double......................................................................................................................................63 Retrait du module SD interne double...............................................................................................................63 Installation du module SD interne double........................................................................................................64 Carte SD interne.....................................................................................................................................................65 Retrait d'une carte SD interne.........................................................................................................................65 Installation d'une carte SD interne..................................................................................................................65 Carte contrôleur de stockage intégrée...................................................................................................................66 Retrait de la carte contrôleur de stockage intégrée........................................................................................66 Installation de la carte contrôleur de stockage intégrée.................................................................................67 Carte fille réseau.....................................................................................................................................................68 Retrait de la carte fille réseau..........................................................................................................................68 Installation de la carte fille réseau...................................................................................................................69 Processeurs............................................................................................................................................................69 Retrait d'un processeur....................................................................................................................................69 Installation d'un processeur............................................................................................................................72 Blocs d'alimentation...............................................................................................................................................74 Alimentation de rechange................................................................................................................................74 Retrait d'un bloc d'alimentation en CA.............................................................................................................74 Installation d'un bloc d'alimentation en CA.....................................................................................................75 Instructions de câblage pour un bloc d'alimentation en CC............................................................................76 Retrait d'un bloc d'alimentation en CC.............................................................................................................78 Installation d'un bloc d'alimentation en CC......................................................................................................79 Retrait d'un cache de bloc d'alimentation.......................................................................................................80 Installation du cache de bloc d'alimentation...................................................................................................80 Pile du système.......................................................................................................................................................81 Remplacement de la pile du système...............................................................................................................81 Fond de panier des disques durs............................................................................................................................82 Retrait du fond de panier des disques durs.....................................................................................................82 Installation du fond de panier des disques durs..............................................................................................84 Assemblage du panneau de commande................................................................................................................85 Retrait de la carte du panneau de commande.................................................................................................85 Installation de la carte du panneau de commande..........................................................................................86 Retrait du panneau de commande...................................................................................................................86 Installation du panneau de commande............................................................................................................87Module VGA............................................................................................................................................................88 Retrait du module VGA.....................................................................................................................................88 Installation du module VGA..............................................................................................................................89 Carte système.........................................................................................................................................................90 Retrait de la carte système..............................................................................................................................90 Installation de la carte système.......................................................................................................................92 Chapitre 4: Dépannage du système..........................................................................................93 La sécurité en priorité, pour vous et votre système...............................................................................................93 Dépannage des échecs de démarrage du système...............................................................................................93 Dépannage des connexions externes....................................................................................................................93 Dépannage du sous-système vidéo........................................................................................................................93 Dépannage d'un périphérique USB........................................................................................................................93 Dépannage d'un périphérique d'E/S série..............................................................................................................94 Dépannage d'une carte réseau..............................................................................................................................94 Dépannage d'un système mouillé...........................................................................................................................95 Dépannage d'un système endommagé..................................................................................................................95 Dépannage de la pile du système...........................................................................................................................96 Dépannage des blocs d'alimentation.....................................................................................................................96 Dépannage des problèmes de refroidissement.....................................................................................................97 Dépannage des ventilateurs de refroidissement...................................................................................................97 Dépannage de la mémoire système.......................................................................................................................97 Dépannage d'une clé USB interne.........................................................................................................................98 Dépannage d'une carte SD....................................................................................................................................99 Dépannage d'un lecteur optique............................................................................................................................99 Dépannage d'une unité de sauvegarde sur bande..............................................................................................100 Dépannage d'un disque dur..................................................................................................................................100 Dépannage d'un contrôleur de stockage.............................................................................................................101 Dépannage des cartes d'extension......................................................................................................................102 Dépannage des processeurs................................................................................................................................103 Chapitre 5: Utilisation des diagnostics du système..............................................................105 Dell Online Diagnostics.........................................................................................................................................105 Diagnostics du système intégré Dell....................................................................................................................105 Quand utiliser les diagnostics intégrés du système......................................................................................105 Exécution des diagnostics intégrés du système............................................................................................105 Commandes du diagnostic du système..........................................................................................................106 Chapitre 6: Cavaliers et connecteurs......................................................................................107 Paramètres des cavaliers de la carte système....................................................................................................107 Connecteurs de la carte système.........................................................................................................................108 Désactivation d'un mot de passe oublié...............................................................................................................110Chapitre 7: Caractéristiques techniques................................................................................111 Chapitre 8: Messages système................................................................................................115 Messages LCD......................................................................................................................................................115 Affichage des messages sur l'écran LCD......................................................................................................115 Suppression des messages affichés sur l'écran LCD....................................................................................115 Messages d'erreur du système............................................................................................................................115 Messages d'avertissement..................................................................................................................................134 Messages de diagnostic.......................................................................................................................................134 Messages d'alerte................................................................................................................................................135 Chapitre 9: Obtention d'aide.....................................................................................................137 Contacter Dell.......................................................................................................................................................13781 À propos du système Voyants et fonctions du panneau avant Figure 1. Voyants et fonctions du panneau avant Élément Voyant, bouton ou connecteur Icône Description 1 Voyant de mise sous tension, bouton d'alimentation Le voyant de mise sous tension s'allume lorsque le système est allumé. Le bouton d'alimentation contrôle l'alimentation fournie au système. REMARQUE: Si vous éteignez un ordinateur utilisant un système d'exploitation compatible ACPI en appuyant sur le bouton d'alimentation, le système peut effectuer un arrêt normal avant la mise hors tension de l'ordinateur. 2 Bouton NMI Ce bouton permet de résoudre les erreurs liées aux logiciels ou aux pilotes de périphériques rencontrées avec certains systèmes d'exploitation. Appuyez sur ce bouton à l'aide de la pointe d'un trombone. Appuyez sur ce bouton uniquement si un technicien de support qualifié vous indique de le faire ou si cela est indiqué dans la documentation du système d'exploitation. 3 Bouton d'identification du système Les boutons d'identification du système qui se trouvent sur les panneaux avant et arrière peuvent être utilisés pour localiser un système particulier dans un rack. Lorsque vous appuyez sur un de ces boutons, le panneau LCD qui se trouve à l'avant et le voyant d'état de système qui se trouve à l'arrière clignotent en bleu jusqu'à ce que vous appuyiez de nouveau sur un des boutons. Appuyez pour faire basculer l'ID du système. Si le système cesse de répondre pendant l'auto-test de démarrage, appuyez sur le bouton de l'ID du système et maintenez-le enfoncé pendant plus de cinq secondes pour entrer en mode d'avancement du BIOS. 9Élément Voyant, bouton ou connecteur Icône Description Pour réinitialiser l'iDRAC (si non désactivé pendant la configuration iDRAC F2) appuyez sur le bouton et maintenez-le enfoncé pendant plus de 15 secondes. 4 connecteur USB (2) Vous permet d'insérer des périphériques USB dans le système. Les ports sont conformes à USB 2.0. 5 Lecteur optique (en option) Un lecteur SATA DVD-ROM ou DVD+/-RW. REMARQUE: Les périphériques DVD sont uniquement des périphériques de données. 6 Logement de carte de média vFlash Permet d'insérer une carte de support vFlash. 7 Boutons de menu de l'écran LCD Permettent de naviguer dans le menu de l'écran LCD du panneau de commande. 8 Écran LCD Affiche l'ID du système, les informations d'état et les messages d'erreur du système. L'écran LCD est bleu lorsque le système fonctionne normalement. Il est orange lorsque le système nécessite une intervention. Il affiche alors un code d'erreur suivi d'un texte descriptif. REMARQUE: Si le système est connecté à l'alimentation secteur et si une erreur a été détectée, l'écran LCD s'allume en orange, que le système soit allumé ou non. 9 Plaquette d'information Cache coulissant sur lequel figure l'étiquette, qui vous permet d'enregistrer des informations système, telles que le numéro de service, la carte de réseau, l'adresse MAC, etc, selon vos besoins. 10 Connecteur vidéo Permet de connecter un moniteur VGA au système. 11 Disques durs Jusqu'à seize disques durs de 2,5 pouces remplaçables à chaud. Fonctionnalités de l'écran LCD Le panneau LCD du système fournit des informations système et des messages d'état et d'erreur pour indiquer que le système fonctionne correctement ou qu'il a un problème. Reportez-vous à la section Messages d'erreur LCD pour en savoir plus sur les codes d'erreurs spécifiques. • Le rétro-éclairage de l'écran LCD est de couleur bleue en fonctionnement normal et orange en cas d'erreur. • Lorsque le système est en mode veille, l'écran LCD n'est pas rétro-éclairé. Pour activer le rétroéclairage, appuyez sur le bouton Sélectionner, Gauche ou Droite de l'écran LCD. • Le rétro-éclairage de l'écran LCD reste inactif si l'affichage de messages a été désactivé via l'utilitaire iDRAC, l'écran LCD ou d'autres outils. 10Figure 2. Fonctionnalités de l'écran LCD Élément Bouton Description 1 Gauche Fait revenir le curseur étape par étape. 2 Sélectionner Permet de sélectionner l'élément de menu mis en surbrillance à l'aide du curseur. 3 Droite Fait avancer le curseur étape par étape. Durant le défilement des messages : • Appuyez une fois pour augmenter la vitesse de défilement. • Appuyez de nouveau pour arrêter le défilement. • Appuyez une nouvelle fois pour rétablir la vitesse de défilement par défaut. • Appuyez encore une fois pour répéter le cycle. Écran d'accueil L'écran d'accueil affiche des informations sur le système qui sont configurables par l'utilisateur. Cet écran est affiché lors d'un fonctionnement système normal quand il n'y a pas de messages d'état ou d'erreurs. Lorsque le système est en mode de veille, le rétro-éclairage LCD s'éteint après cinq minutes d'inactivité s'il n'y a pas de messages d'erreur. Appuyez sur l'un des trois boutons de navigation (sélectionner, gauche ou droit) pour afficher l'écran d'accueil. Pour retourner à l'écran d'accueil à partir d'un autre menu, continuez de sélectionner la flèche haut jusqu'à ce que l'icône Accueil soit affichée, puis sélectionnez l'icône Accueil. Sur l'écran d'accueil, appuyez sur le bouton Sélectionner pour accéder au menu principal. Menu Configuration REMARQUE: Si vous sélectionnez une option dans le menu Setup (Configuration), vous devez confirmer l'option avant de passer à l'étape suivante. 11Option Description iDRAC Sélectionnez DHCP ou Static IP (IP statique) pour configurer le mode réseau. Si Static IP (IP statique) est sélectionné, les champs disponibles sont IP, Subnet (Sub) (sous-réseau) et Gateway (Gtw) (passerelle). Sélectionnez Setup DNS (configuration de DNS) pour activer une DNS et pour afficher les adresses de domaine. Deux entrées de DNS séparées sont disponibles. Set Error (Définition du mode d'erreur) Sélectionnez SEL pour afficher des messages d'erreur LCD dans un format qui correspond à la description IPMI dans le journal SEL. Il s'agit d'une méthode pratique lorsque vous essayez de faire correspondre un message LCD avec une entrée SEL. Sélectionnez Simple pour afficher des messages d'erreur LCD dans une description conviviale simplifiée. Référez-vous à la section Messages d'erreur système pour voir une liste de messages dans ce format. Set Home (Définition de l'écran d'accueil) Sélectionnez l'information par défaut que vous voulez afficher sur l'écran d'accueil LCD. Référezvous à la section View Menu (Menu Vue) pour voir les options et les articles d'options qui peuvent être réglés par défaut sur l'écran d'accueil. Menu Vue REMARQUE: Si vous sélectionnez une option dans le menu View (Vue), vous devez confirmer l'option avant de passer à l'étape suivante. Option Description IP iDRAC Affiche les adresses IPv4 ou IPv6 de l'iDRAC7. Il s'agit de l'adresse DNS (principale et secondaire), de l'adresse de passerelle, de l'adresse IP et de l'adresse de sous-réseau (l'IPv6 ne comprend par de sous-réseau). MAC Affiche les adresses MAC des périphériques iDRAC, iSCSI ou réseau. Nom Affiche le nom d'hôte, le modèle ou une chaîne définie par l'utilisateur pour le système. Numéro Affiche le numéro d'inventaire ou le numéro de service du système. Alimentation Affiche la sortie d'alimentation du système en UET/h ou watts. Le format d'affichage peut être configuré dans le sous-menu Set home (Configurer accueil) du menu Setup (Configurer). Température Affiche la température du système en Celsius et Fahrenheit. Le format d'affichage peut être configuré dans le sous-menu Set home (Configurer accueil) du menu Setup (Configurer). Voyants de diagnostic Les voyants de diagnostic sur le panneau avant du système affichent l'état pendant le démarrage du système. REMARQUE: Les voyants de diagnostic ne sont pas présents lorsque le système est doté d'un écran LCD. La section suivante décrit les conditions du système et les mesures correctives possibles associées à ces voyants : 12Voyant électrique État Mesure corrective Le voyant clignote en orange si le système rencontre une erreur électrique (par exemple, une tension en dehors des limites ou un bloc d'alimentation ou un régulateur de tension défaillant). Reportez-vous au journal des événements système ou aux messages du système pour des problèmes particuliers. Si le problème vient du bloc d'alimentation, vérifiez la DEL du bloc d'alimentation. Réinsérez le bloc d'alimentation en le retirant et le réinstallant. Si le problème persiste, reportez-vous à la section Obtention d'aide. Voyant de température État Mesure corrective Le voyant clignote en orange si le système rencontre une erreur de température (par exemple, une température en dehors des limites ou un ventilateur défaillant). Assurez-vous qu'aucune des conditions suivantes n'existe : • Retrait ou panne de l'un des ventilateurs. • Retrait du capot du système, du carénage de refroidissement, de la plaque de recouvrement EMI, du cache de barrette de mémoire ou de plaque de recouvrement arrière. • La température ambiante est trop élevée. • La circulation de l'air extérieur est bloquée. Voir Obtention d'aide. Voyant de mémoire État Mesure corrective Le voyant clignote en orange si une erreur de mémoire survient. Reportez-vous au journal des événements système ou aux messages système pour localiser la mémoire défaillante. Réinstallez le périphérique mémoire. Si le problème persiste, reportez-vous à la section Obtention d'aide. Codes des voyants des disques durs Figure 3. Voyants de disque dur 131. voyant d'activité du disque dur (vert) 2. voyant d'état du disque dur (vert et orange) REMARQUE: Si le disque dur est en mode Advanced Host Controller Interface (AHCI), le voyant de l'état (sur la droite) ne fonctionne pas et reste éteint. Codes des voyants d'état des disques (RAID uniquement) État Voyant vert clignotant deux fois par seconde Identification du disque/préparation au retrait Éteint Disque prêt pour insertion ou retrait REMARQUE: Le voyant d'état des disques reste éteint jusqu'à ce que tous les disques soient initialisés après la mise sous tension du système. Il n'est pas possible d'insérer ou de retirer des disques au cours de cette période. Vert clignotant, puis orange, puis extinction Panne du lecteur prévisible Orange clignotant quatre fois par seconde Disque en panne Vert clignotant lentement Disque en cours de reconstruction Vert fixe Disque en ligne Voyant vert clignotant pendant trois secondes, orange pendant trois secondes et extinction pendant six secondes Reconstruction annulée Voyants et caractéristiques du panneau arrière Figure 4. Voyants et caractéristiques du panneau arrière Élément Voyant, bouton ou connecteur Icône Description 1 Bouton d'identification du système Les boutons d'identification sur les panneaux avant et arrière peuvent être utilisés pour localiser un système particulier à l'intérieur d'un rack. Lorsque vous appuyez sur un de ces boutons, le panneau LCD à l'avant et l'indicateur d'état du système à l'arrière clignotent jusqu'à ce que vous appuyiez de nouveau sur un des boutons. Appuyez pour faire basculer l'ID du système. Si le système cesse de répondre pendant l'auto-test de démarrage, appuyez sur le bouton de l'ID du système et maintenez-le enfoncé pendant plus de cinq secondes pour entrer en mode d'avancement du BIOS. 14Élément Voyant, bouton ou connecteur Icône Description Pour réinitialiser l'iDRAC (s'il n'a pas été désactivé au cours de la configuration d'iDRAC F2), appuyez sur le bouton et maintenez-le enfoncé pendant plus de 15 secondes. 2 Connecteur d'identification du système Permet de connecter le module de voyants d'état du système en option au moyen du passe-câbles en option. 3 Port iDRAC7 Enterprise Port de gestion dédié. REMARQUE: Le port est prêt à être utilisé seulement si la licence iDRAC7 Enterprise est installée sur votre système. 4 Connecteur série Permet de connecter un périphérique série au système. 5 Logement de la carte d'extension PCIe (carte adaptatrice de connexion 2) Vous permet de connecter une carte d'extension PCIe. 6 Connecteur vidéo Permet de connecter un moniteur VGA au système. 7 Connecteurs USB (2) Permet de connecter des périphériques USB au système. Les ports sont compatibles USB 2.0. 8 Connecteurs Ethernet (4) Quatre connecteurs de carte réseau10/100/1000 Mbp intégrés ou Quatre connecteurs intégrés : • Deux connecteurs de carte réseau10/100/1000 Mbp intégrés • Deux connecteurs100 Mbp/1 Gbp/10 Gbp SFP+ intégrés 9 Logement de la carte d'extension PCIe (carte adaptatrice de connexion 3) Vous permet de connecter une carte d'extension PCIe. 10 Alimentation (PSU1) CA 495 W, 750 W ou 1100 W ou CC 1100 W (si disponible) 11 Alimentation (PSU2) 15Codes des voyants de carte réseau Figure 5. Voyant de la carte réseau 1. voyant de liaison 2. voyant d'activité Voyant Code du voyant Les voyants de liaison et d'activité sont éteints La carte réseau n'est pas connectée au réseau. Le voyant de liaison est vert La carte réseau est connectée à un réseau valide à la vitesse de débit de port maximale (1 Gb/s ou 10 Gb/s). Le voyant de liaison est orange La carte réseau est connectée à un réseau valide à un débit moindre que son débit de port maximal. Le voyant d'activité clignote en vert. Des données réseau sont en cours d'envoi ou de réception. Codes du voyant d'alimentation Chaque bloc d'alimentation en CA est équipé d'une poignée translucide allumée et chaque bloc d'alimentation en CC (le cas échéant) a un voyant qui indique si l'alimentation est normale ou si une erreur d'alimentation s'est produite. Figure 6. Voyant d'état du bloc d'alimentation en CA 1. Indicateur d'état/poignée du bloc d'alimentation en CA 16Figure 7. Voyant d'état du bloc d'alimentation en CC 1. Voyant d'état du bloc d'alimentation en CC Comportement du voyant d'alimentation État Éteint Non connecté. Vert La poignée/le voyant s'allument en vert pour signaler qu'une source d'alimentation valide est connectée au bloc d'alimentation et que celui-ci est opérationnel. Orange clignotant Un voyant orange indique un problème lié au bloc d'alimentation. PRÉCAUTION: Lorsque vous corrigez une non-correspondance de bloc d'alimentation, remplacez uniquement le bloc d'alimentation dont le voyant clignote. Si vous remplacez l'autre bloc d'alimentation pour créer une paire correspondante, une erreur peut se produire et le système peut s'éteindre de manière péremptoire. Pour modifier la configuration de tension de sortie haute en tension de sortie basse, et vice versa, vous devez éteindre le système. PRÉCAUTION: Les blocs d'alimentation en CA prennent en charge des tensions d'entrée de 220 V et 110 V. Lorsque deux blocs d'alimentation identiques reçoivent différentes tensions d'entrée, leur puissance de sortie peut être différente, ce qui occasionne une noncorrespondance. PRÉCAUTION: Si deux blocs d'alimentation sont utilisés, ils doivent être de même type et leur puissance de sortie maximale doit être la même. PRÉCAUTION: La combinaison de blocs d'alimentation CA et CC n'est pas prise en charge et peut provoquer une non-correspondance. Vert clignotant Lorsque vous ajoutez un bloc d'alimentation à chaud, ce voyant indique que les deux blocs d'alimentation ne correspondent pas (en termes d'efficacité, de fonctions, d'état de santé et de tension prise en charge). Remplacez le bloc d'alimentation au voyant clignotant par un bloc d'alimentation aux capacités identiques à celles du bloc d'alimentation installé. 17Autres informations utiles AVERTISSEMENT: Reportez-vous aux informations concernant la sécurité et les réglementations livrées avec votre système. Les informations sur la garantie peuvent être incluses dans ce document ou bien dans un document séparé. • Le Getting Started Guide (Guide de démarrage) présente l'installation de votre système et ses caractéristiques techniques. Ce document est disponible en ligne à l'adresse support.dell.com/manuals. • La documentation fournie avec le rack indique comment installer le système dans un rack, le cas échéant. • Tous les supports fournis avec le système contiennent de la documentation et des outils permettant de configurer et de gérer le système, notamment les supports du système d'exploitation, du logiciel de gestion du système, des mises à jour système et des composants système que vous avez achetés avec le système. • Pour obtenir le nom complet d'une abréviation ou connaître la signification d'un sigle utilisé dans ce tableau, voir Glossary (Glossaire) sur support.dell.com/manuals. REMARQUE: Vérifiez toujours si des mises à jour sont disponibles sur le site support.dell.com/manuals et lisez les informations de mise à jour en premier, car elles remplacent souvent les informations que contiennent les autres documents. 182 Utilisation du gestionnaire de configuration du système et d'amorçage La configuration du système vous permet de gérer le matériel du système et de définir les options au niveau du BIOS. Les touches suivantes permettent d'accéder à certaines fonctions au démarrage du système : Touche Description Permet d'accéder à la configuration du système. Permet d'entrer dans les Services système, ce qui ouvre le Dell Lifecycle Controller 2 (LC2). Le Dell LC2 prend en charge des fonctions de gestion du système telles que le déploiement du système d'exploitation, les diagnostics matériels, les mises à jour de plate-forme et la configuration de plate-forme, à l'aide de l'interface utilisateur graphique. L'ensemble des fonctions exactes du LC2 est déterminé par la licence iDRAC achetée. Pour de plus amples informations, reportez-vous à la documentation Dell LC2. Permet d'accéder au gestionnaire d'amorçage BIOS ou UEFI selon la configuration de démarrage de votre système. Permet de lancer l'amorçage PXE (Preboot eXecution Environment). À partir de la configuration du système, vous pouvez effectuer les tâches suivantes : • Modifier les paramètres NVRAM après l'ajout ou la suppression de matériel • Afficher la configuration matérielle du système • Activer ou désactiver les périphériques intégrés • Définir les seuils de gestion de l'alimentation et des performances • Gérer la sécurité du système Vous pouvez accéder à la configuration du système à l'aide : • du navigateur graphique standard, activé par défaut • du navigateur de texte, activé à l'aide de Console Redirection (Redirection de la console) Pour activer Console Redirection (Redirection de la console), dans System Setup(Configuration du système), sélectionnez System BIOS (BIOS du système) → écran Serial Communication (Communications série) → Serial Communication (Communications série), sélectionnez On with Console Redirection(Activé avec la console de redirection). REMARQUE: Par défaut, le texte d'aide pour le champ sélectionné est affiché dans le navigateur graphique. Pour afficher le texte d'aide dans le navigateur de texte, vous devez appuyer sur la touche . Choix du mode d'amorçage du système Le programme de configuration du système vous permet de spécifier le mode d'amorçage pour l'installation du système d'exploitation : • Le mode d'amorçage du BIOS (par défaut) est l'interface standard d'amorçage au niveau du BIOS. 19• Le mode d'amorçage de l'UEFI est une interface d'amorçage améliorée de 64 bits basée sur des spécifications UEFI et superposée au système du BIOS. Vous devez sélectionner le mode d'amorçage dans le champ Boot Mode (Mode d'amorçage) de l'écran Boot Settings (Paramètres d'amorçage) dans System Setup (Configuration du système). Une fois le mode d'amorçage spécifié, le système démarre dans le mode spécifié et vous pouvez procéder à l'installation de votre système d'exploitation depuis ce mode. Ensuite, vous devez redémarrer le système à l'aide du même mode d'amorçage (BIOS ou UEFI) pour accéder au système d'exploitation installé. Si vous essayez de démarrer le système à partir d'un autre mode d'amorçage, le système se bloquera au démarrage. REMARQUE: Les systèmes d'exploitation doivent être compatibles avec l'UEFI afin d'être installés en mode d'amorçage UEFI. Les systèmes d'exploitation DOS et 32 bits ne prennent pas en charge l'UEFI et ne peuvent être installés qu'à partir du mode d'amorçage BIOS. REMARQUE: Pour obtenir les dernières informations sur les systèmes d'exploitation pris en charge, rendez-vous sur le site dell.com/ossupport. Accès à la configuration du système 1. Allumez ou redémarrez le système. 2. Appuyez sur dès que vous avez vu le message suivant : = System Setup (Configuration du système) Si le système d'exploitation commence à se charger alors que vous n'avez pas encore appuyé sur , attendez que le système finisse de démarrer, puis redémarrez-le et réessayez. Réponse aux messages d'erreur Si un message d'erreur s'affiche pendant que le système s'amorce, prenez en note le message. Pour en savoir plus, référez-vous à la section Messages d'erreur du système. REMARQUE: Il est normal qu'un message s'affiche lorsque vous redémarrez le système après avoir installé une mise à niveau de mémoire. Utilisation des touches de navigation de la configuration du système Touches Action Flèche vers le haut Permet de revenir au champ précédent. Flèche vers le bas Permet de passer au champ suivant. Vous permet de saisir une valeur dans le champ sélectionné (le cas échéant) ou de suivre le lien dans le champ. Barre d'espacement Permet d'étendre ou de réduire la liste déroulante, le cas échéant. Passe à l'objectif suivant. REMARQUE: Seulement pour le navigateur de graphiques standard. <Échap> Permet de passer à la page précédente jusqu'à ce que vous voyiez l'écran principal. Appuyez sur <Échap> dans l'écran principal pour afficher un message qui vous invite à enregistrer toutes les modifications non enregistrées et pour redémarrer le système. 20Touches Action Permet d'afficher le fichier d'aide de la configuration du système. REMARQUE: Pour la plupart des options, les modifications effectuées sont enregistrées mais ne prennent effet qu'au redémarrage du système. Options de configuration du système Écran principal System Setup (Configuration du système) REMARQUE: Appuyez sur pour réinitialiser les paramètres du BIOS ou de l'UEFI à leur valeur par défaut. Élément de menu Description System BIOS (BIOS du système) Cette option est utilisée pour afficher et configurer les paramètres du BIOS. iDRAC Settings (Paramètres iDRAC) Cette option est utilisée pour afficher et configurer les paramètres iDRAC. Device Settings (Paramètres du périphérique) Cette option est utilisée pour afficher et configurer les paramètres du périphérique. Écran System BIOS (BIOS du système) REMARQUE: Les options du programme de configuration du système varient en fonction de la configuration du système. REMARQUE: Les valeurs par défaut du programme de configuration du système sont répertoriées sous l'option correspondante dans les sections suivantes, le cas échéant. Élément de menu Description Informations système Permet d'afficher les informations sur le système telles que le nom du modèle du système, la version du BIOS, le numéro de service, etc. Memory Settings (Paramètres de la mémoire) Permet d'afficher les informations et les options relatives à la mémoire installée. Processor settings (Paramètres du processeur) Permet d'afficher les informations et les options relatives au processeur telles que la vitesse, la taille du cache, etc. SATA Settings (Paramètres SATA) Permet d'afficher les options permettant d'activer ou de désactiver le contrôleur et les ports SATA intégrés. Boot Settings (Paramètres d'amorçage) Permet d'afficher les options pour indiquer le mode d'amorçage (BIOS ou UEFI). Vous permet de modifier les paramètres d'amorçage UEFI et BIOS. Integrated Devices (Périphériques intégrés) Permet d'afficher les options permettant d'activer ou de désactiver les contrôleurs de périphérique et les ports intégrés, et de spécifier les fonctionnalités et options associées. Serial Communication (Communications série) Permet d'afficher les options permettant d'activer ou de désactiver les ports série et de spécifier les fonctionnalités et options associées. 21Élément de menu Description System Profile Settings (Paramètres du profil du système) Permet d'afficher les options permettant de modifier les paramètres de gestion de l'alimentation du processeur, la fréquence de la mémoire, etc. System Security (Sécurité du système) Permet d'afficher les options permettant de configurer les paramètres de sécurité du système tels que le mot de passe du système, le mot de passe de configuration, la sécurité TPM, etc. Permet également d'activer ou de désactiver la prise en charge pour la mise à jour BIOS locale, le bouton d'alimentation et le bouton INM du système. Miscellaneous Settings (Paramètres divers) Permet d'afficher les options permettant de modifier la date du système, l'heure, etc. Écran System Information (Informations sur le système) Élément de menu Description System Model Name (Nom du modèle du système) Affiche le nom du modèle du système. System BIOS Version (Version du BIOS du système) Affiche la version du BIOS installée sur le système. System Service Tag (Numéro de service du système) Affiche le numéro de service du système. System Manufacturer (Fabricant du système) Affiche le nom du fabricant du système. System Manufacturer Contact Information (Coordonnées du fabricant du système) Affiche les coordonnées du fabricant du système. Écran Memory Settings (Paramètres de la mémoire) Élément de menu Description System Memory Size (Taille de la mémoire système) Indique la taille de la mémoire installée dans le système. System Memory Type (Type de mémoire système) Indique le type de mémoire installée dans le système. System Memory Speed (Vitesse de la mémoire système) Indique la vitesse de la mémoire système. System Memory Voltage (Tension de la mémoire système) Indique la tension de la mémoire système. Video Memory (Mémoire vidéo) Affiche la quantité de mémoire vidéo disponible. System Memory Testing (Test de la mémoire système) Indique si les tests de la mémoire système sont exécutés pendant l'amorçage du système. Les options sont Enabled (Activé) et Disabled (Désactivé).Par défaut, l'option System Memory Testing (Test de la mémoire système) est réglée sur Disabled (Désactivé). Memory Operating Mode (Mode de fonctionnement de la mémoire) Indique le mode de fonctionnement de la mémoire. Les options disponibles dépendant de la configuration de la mémoire du système sont Optimizer Mode 22Élément de menu Description (Mode optimisé), Advanced ECC Mode (Mode ECC avancé), Mirror Mode (Mode miroir), Spare Mode (Mode réserve) et Spare with Advanced ECC Mode (Mode réserve et ECC avancé). Par défaut, l'option Memory Operating Mode (Mode de fonctionnement de la mémoire) est réglée sur Optimizer Mode (Mode optimisé). REMARQUE: Le mode de fonctionnement de la mémoire peut avoir des paramètres par défaut et des options disponibles différents selon la configuration de la mémoire. Node Interleaving (Entrelacement de nœuds) Si ce champ est réglé sur Enabled (Activé), l'entrelacement de nœuds est pris en charge si une configuration de mémoire symétrique est installée. Si le champ est réglé sur Disabled (Désactivé), le système prend en charge des configurations de mémoire (asymétriques) d'architecture de la mémoire non uniforme (NUMA). Par défaut, l'option Node Interleaving (Entrelacement de nœuds) est réglée sur Disabled (Désactivé). Serial Debug Output (Sortie de débogage en série) Réglé par défaut sur désactivé. Écran Processor Settings (Paramètres du processeur) Élément de menu Description Logical Processor (Processeur logique) Vous permet d'activer ou de désactiver les processeurs logiques et d'activer le nombre de processeurs logiques. Si l'option Logical Processor (Processeur logique) est réglée sur Enabled (Activé), le BIOS affiche tous les processeurs logiques. Si cette option est réglée sur Disabled (Désactivé), le BIOS n'affiche qu'un processeur logique par cœur. Par défaut, l'option Logical Processor (Processeur logique) est réglée sur Enabled (Activé). QPI Speed (Vitesse QPI) Vous permet de régler les paramètres de débit de données QuickPath Interconnect. Par défaut, l'option QPI Speed (Vitesse QPI) est réglée sur Maximum data rate (Débit de données maximal). REMARQUE: L'option QPI Speed (Vitesse QPI) est affichée uniquement lorsque les deux processeurs sont installés. Alternate RTID (Requestor Transaction ID) Setting (Paramètre RTID alterné) Vous permet d'attribuer plus de RTID au support à distance augmentant ainsi la performance du cache entre les supports ou de travailler en mode normal pour NUMA. Par défaut, Alternate RTID (Requestor Transaction ID) Setting (Paramètre RTID alterné) est réglé sur Disabled (Désactivé). Virtualization Technology (Technologie de virtualisation) Vous permet d'activer ou de désactiver les capacités matérielles supplémentaires fournies par la technologie de virtualisation. Par défaut, l'option Virtualization Technology (Technologie de virtualisation) est réglée sur Enabled (Désactivé). Adjacent Cache Line Prefetch (Prérécupération de la ligne de mémoire cache adjacente) Vous permet d'optimiser le système pour des applications nécessitant une utilisation élevée de l'accès séquentiel de la mémoire. Par défaut, l'option Adjacent Cache Line Prefetch (Prérécupération de la ligne de mémoire cache adjacente) est réglée sur Enabled (Activé). Vous pouvez désactiver cette option 23Élément de menu Description pour des applications nécessitant une utilisation élevée à un accès aléatoire à la mémoire. Hardware Prefetcher (Prérécupérateur de matériel) Vous permet d'activer ou de désactiver le prérécupérateur de matériel. Par défaut, l'option Hardware Prefetcher (Prérécupérateur de matériel) est réglée sur Enabled (Activé). DCU Streamer Prefetcher (Prérécupération du dévideur d'antémémoire de données) Vous permet d'activer ou de désactiver le prérécupérateur du dévideur d'antémémoire de données. Par défaut, l'option DCU Streamer Prefetcher (Prérécupération du dévideur d'antémémoire de données) est réglée sur Enabled (Activé). DCU IP Prefetcher (Prérécupération de l'adresse IP de l'antémémoire de données) Vous permet d'activer ou de désactiver le prérécupérateur de l'adresse IP du dévideur d'antémémoire de données. Par défaut, l'option DCU IP Prefetcher (Prérécupération de l'adresse IP de l'antémémoire de données) est réglée sur Enabled (Activé). Execute Disable (Exécution de la désactivation) Vous permet d'activer ou de désactiver la technologie de protection mémoire d'exécution de la désactivation. Par défaut, l'option Execute Disable (Exécution de la désactivation) est réglée sur Enabled (Activé). Number of Cores per Processor (Nombre de cœurs par processeur) Vous permet de contrôler le nombre de cœurs disponibles pour chaque processeur. Par défaut, l'option Number of Cores per Processor (Nombre de cœurs par processeur) est réglée sur All (Tous). Processor 64-bit Support (Prise en charge des processeurs 64 bits) Indique si le ou les processeurs prennent en charge les extensions 64 bits. Processor Core Speed (Vitesse du cœur du processeur) Affiche la fréquence maximale du cœur du processeur. Processor Bus Speed (Vitesse de bus du processeur) Affiche la vitesse de bus des processeurs. REMARQUE: L'option de la vitesse de bus du processeur est affichée uniquement lorsque les deux processeurs sont installés. Processeur 1 REMARQUE: Les paramètres suivants sont affichés pour chaque processeur installé dans le système. Family-Model-Stepping (FamilleModèle-Stepping) Affichez la famille, le modèle et le stepping du processeur tels que définis par Intel. Brand (Marque) Affiche le nom de la marque signalé par le processeur. (Level 2 Cache) Cache de niveau 2 Affiche la taille de la mémoire cache de niveau 2 Level 3 Cache (Cache de niveau 3) Affiche la taille de la mémoire cache L3 Number of Cores (Nombre de noyaux) Indique le nombre de cœurs activés par processeur. 24Écran SATA Settings (Paramètres SATA) Élément de menu Description Embedded SATA (SATA intégré) Permet au disque SATA intégré d'être réglé sur les modes Off (Éteint), ATA, AHCI ou RAID. Par défaut, la fonction Embedded SATA (SATA intégré) est réglée sur AHCI. Port E Auto permet une prise en charge du BIOS pour le périphérique fixé au port SATA E. Off (Éteint) désactive la prise en charge du BIOS pour le périphérique. Par défaut, le port E est réglé sur Auto. Port F Auto permet une prise en charge du BIOS pour le périphérique fixé au port SATA F. Off (Éteint) désactive la prise en charge du BIOS pour le périphérique. Par défaut, le port F est réglé sur Auto. Écran Boot Settings (Paramètres d'amorçage) Élément de menu Description Boot Mode (Mode d'amorçage) Vous permet de définir le mode d'amorçage du système. PRÉCAUTION: La permutation du mode d'amorçage peut empêcher le démarrage du système si le système d'exploitation n'a pas été installé selon le même mode d'amorçage. Si le système d'exploitation prend en charge l'UEFI, vous pouvez définir cette option sur UEFI. Le réglage de ce champ sur BIOS permet la compatibilité avec des systèmes d'exploitation non UEFI. Par défaut, l'option Boot Mode (Mode d'amorçage) est réglée sur BIOS. REMARQUE: Le réglage de ce champ sur UEFI désactive le menu BIOS Boot Settings (Paramètres d'amorçage du BIOS). Le réglage de ce champ sur BIOS désactive le menu UEFI Boot Settings (Paramètres d'amorçage UEFI). Boot Sequence Retry (Réexécution de la séquence d'amorçage) Vous permet d'activer ou de désactiver la fonction de réexécution de la séquence d'amorçage. Si ce champ est activé et que le système n'arrive pas à démarrer, ce dernier ré-exécute la séquence d'amorçage après 30 secondes. Par défaut, l'option Boot Sequence Retry (Réexécution de la séquence d'amorçage) est réglée sur Disabled (Désactivé). BIOS Boot Settings (Paramètres d'amorçage BIOS) Vous permet d'activer ou de désactiver les options d'amorçage du BIOS. REMARQUE: Cette option est activée uniquement si le mode d'amorçage est le BIOS. UEFI Boot Settings (Paramètres d'amorçage UEFI) Vous permet d'activer ou de désactiver les options d'amorçage de l'UEFI. REMARQUE: Cette option est activée uniquement si le mode d'amorçage est l'UEFI. One-Time Boot (Amorçage ponctuel) Vous permet d'activer ou de désactiver l'amorçage ponctuel depuis un périphérique sélectionné. 25Écran Integrated Devices (Périphériques intégrés) Élément de menu Description Integrated RAID controller (Contrôleur RAID intégré) Vous permet d'activer ou de désactiver le contrôleur RAID intégré. Par option, l'option Integrated RAID Controller (Contrôleur RAID intégré) est réglée sur Enabled (Activé). User Accessible USB Ports (Ports USB accessibles à l'utilisateur) Vous permet d'activer ou de désactiver les ports USB accessibles à l'utilisateur. Si vous sélectionnez Only Back Ports On (Seuls les ports arrières sont activés) les ports USB avants seront désactivés, et si vous sélectionnez All ports Off (Tous les ports sont désactivés), les ports USB avants et arrières seront désactivés. Par défaut, l'option User Accessible USB Ports (Ports accessibles à l'utilisateur) est réglée sur All ports On (Tous les ports sont activés). Internal USB Port (Port USB interne) Vous permet d'activer ou de désactiver le port interne USB. Par défaut, l'option Internal USB Port (Port USB interne) est réglée sur On (Activé). Internal SD Card Port (Port de carte SD interne) Active ou désactive le port de la carte SD interne du système. Par défaut, l'option Internal SD Card Port (Port de la carte SD interne du système) est réglée sur On (Activé). REMARQUE: Cette option s'affiche seulement si le IDSDM est installé sur la carte système. Internal SD Card Redundancy (Redondance de la carte SD interne) Lorsque l'option est réglée sur le mode Mirror (Miroir), les données sont écrites sur les deux cartes SD. Si l'une des cartes tombe en panne, les données sont écrites sur la carte SD active. Les données depuis cette carte sont copiées sur la carte SD de remplacement au prochain démarrage. Par défaut, l'option Internal SD Card Redundancy (Redondance de la carte SD interne) est définie sur Mirror (Miroir). REMARQUE: Cette option s'affiche seulement si le IDSDM est installé sur la carte système. Integrated Network Card 1 (Carte réseau intégrée 1) Vous permet d'activer ou de désactiver la carte réseau intégrée. Par défaut, l'option Integrated Network Card 1 (Carte réseau intégrée 1) est réglée sur Enabled (Activé). OS Watchdog Timer (Temporisateur de surveillance du système d'exploitation) Vous permet d'activer ou de désactiver le temporisateur de surveillance du système d'exploitation. Lorsque ce champ est activé, le système d'exploitation initialise le temporisateur et ce dernier aide à la récupération du système d'exploitation. Par défaut, l'option OS Watchdog Timer (Temporisateur de surveillance du système d'exploitation) est réglée sur Disabled (Désactivé). Embedded Video Controller (Contrôleur vidéo intégré) Vous permet d'activer ou de désactiver Embedded Video Controller (Contrôleur vidéo intégré). Par défaut, le contrôleur vidéo intégré est réglé sur Enabled (Activé). SR-IOV Global Enable (Activation des périphériques SR-IOV avec la commande globale) Vous permet d'activer ou de désactiver la configuration du BIOS des périphériques SRIOV (Single Root I/O Virtualization). Par défaut, l'option SR-IOV Global Enable (Activation des périphériques SR-IOV avec la commande globale) est réglée sur Disabled (Désactivé) Slot Disablement (Désactivation des logements) Vous permet d'activer ou de désactiver des logements PCIe disponibles sur votre système. La fonction Slot Disablement (Désactivation des logements) contrôle la configuration des cartes PCIe installées dans un logement spécifique. 26Élément de menu Description PRÉCAUTION: La désactivation de logement doit être utilisée seulement lorsque la carte périphérique installée empêche l'amorçage dans le système d'exploitation ou lorsqu'elle cause des délais lors du démarrage du système. Si le logement est désactivé, l'option ROM et le pilote UEFI sont aussi désactivés. Écran Serial Communications (Communications série) Élément de menu Description Serial Communication (Communications série) Vous permet de sélectionner des périphériques de communication série (Périphérique série 1 et Périphérique série 2) dans le BIOS. La redirection de la console BIOS peut aussi être activée et l'adresse du port utilisée peut être spécifiée. Par défaut, l'option Serial Communication (Communication série) est réglée sur On without Console Redirection (Activée sans redirection de console). Serial Port Address (Adresse de port série) Vous permet de définir l'adresse de port pour les périphériques série. Par défaut, l'option Serial Port Address (Adresse de port série) est réglée sur Serial Device 1=COM2, Serial Device 2=COM1 (périphérique série 1=COM2, périphérique série 2=COM1). REMARQUE: Seul le périphérique série 2 (Serial Device 2) peut être associé aux connectivités SOL (Serial Over LAN). Pour utiliser la redirection de console par SOL, configurez la même adresse de port pour la redirection de console et le périphérique série. External Serial Connector (Connecteur série externe) Vous permet d'associer le connecteur série externe au périphérique série 1, au périphérique série 2 ou au périphérique d'accès à distance. Par défaut, l'option External Serial Connector (Connecteur série externe) est réglée sur Serial Device1 (Périphérique série 1). REMARQUE: Seul le périphérique série 2 peut être associé aux connectivités SOL. Pour utiliser la redirection de console par SOL, configurez la même adresse de port pour la redirection de console et le périphérique série. Failsafe Baud Rate (Débit en bauds de la ligne de secours) Affiche le débit en bauds de la ligne de secours pour la redirection de console. Le BIOS tente de déterminer le débit en bauds automatiquement. Ce débit est utilisé uniquement si la tentative échoue et la valeur ne doit pas être modifiée. Par défaut, l'option Failsafe Baud Rate (Débit en bauds de la ligne de secours) est réglée sur 11520. Remote Terminal Type (Type du terminal distant) Vous permet de définir le type de terminal de console distant. Par défaut, l'option Remote Terminal Type (Type du terminal distant) est réglée sur VT 100/VT220. Redirection After Boot (Redirection après démarrage) Vous permet d'activer ou de désactiver la redirection de console du BIOS lorsque le système d'exploitation est en cours de chargement. Par défaut, l'option Redirection After Boot (Redirection après démarrage) est réglée sur Enabled (Activé). 27Écran System Profile Settings (Paramètres du profil du système) Élément de menu Description System Profile (Profil du système) Vous permet de régler le profil du système. Si vous réglez l'option System Profile (Profil du système) sur un mode autre que Custom (Personnalisé), le BIOS définit automatiquement le reste des options. Vous ne pouvez que modifier le reste des options si le mode est réglé sur Custom (Personnalisé). Par défaut, l'option System Profile (Profil du système) est réglée sur Performance Per Watt Optimized (DAPC) [Performance par watt optimisée (DAPC)]. DAPC correspond à Dell Active Power Controller (Contrôleur de l'alimentation actif Dell). REMARQUE: Les paramètres suivants ne sont disponibles que lorsque System Profile (Profil du système) est réglé sur Custom (Personnalisé). CPU Power Management (Gestion de l'alimentation de l'UC) Vous permet de régler la gestion de l'alimentation de l'UC. Par défaut, l'option CPU Power Management (Gestion de l'alimentation de l'UC) est réglée sur System DBPM (DAPC) [Modulation biphasée différentielle du système (DAPC)]. DBPM correspond à DemandBased Power Management (Gestion de l'alimentation en fonction de la demande). Memory Frequency (Fréquence de la mémoire) Vous permet de définir la fréquence de la mémoire. Par défaut, l'option Memory Frequency (Fréquence de la mémoire) est réglée sur Maximum Performance (Performances maximales). Turbo Boost Vous permet d'activer ou de désactiver le processeur pour faire fonctionner le mode turbo boost. Par défaut, l'option Turbo Boost est réglée sur Enabled (Activé). C1E Vous permet d'activer et de désactiver le processeur pour basculer à un état de performances minimales lorsqu'il est inactif. Par défaut, l'option C1E est réglée sur Enabled (Activé). C States (États C) Vous permet d'activer ou de désactiver le processeur pour fonctionner avec tous les états d'alimentation disponibles. Par défaut, l'option C States (États C) est réglée sur Enabled (Activé). Monitor/Mwait Vous permet d’activer les instructions Monitor/Mwait dans le processeur. Par défaut, l’option Moniteur/Mwait est réglée sur Enabled (Activé) pour tous les profils du système, sauf Custom (Personnalisé). REMARQUE: Cette option peut être désactivée uniquement si l’option C States (États C) du mode Custom (Personnalisé) est désactivée. REMARQUE: Lorsque C States (États C) est activée dans le mode Custom (Personnalisé), la modification du paramètres Monitor/Mwait n’a aucune incidence sur l’alimentation ou les performances du système. Memory Patrol Scrub (Vérification et correction d'erreur de la mémoire) Vous permet de définir la fréquence de vérification et de correction d'erreur de la mémoire. Par défaut, l'option Memory Patrol Scrub (Vérification et correction d'erreur de la mémoire) est réglée sur Standard. Memory Refresh Rate (Taux de rafraîchissement de la mémoire) Vous permet de régler le taux de rafraîchissement de la mémoire. Par défaut, l'option Memory Refresh Rate (Taux de rafraîchissement de la mémoire) est réglée sur 1x. 28Élément de menu Description Memory Operating Voltage (Tension de fonctionnement de la mémoire) Vous permet de régler la sélection de tension des barrettes DIMM. Lorsque l'option est réglée sur Auto, le système règle la tension du système à un paramètre optimal basé sur la capacité des barrettes DIMM ainsi que le nombre de barrettes DIMM installées. Par défaut, l'option Memory Operating Voltage (Tension de fonctionnement de la mémoire) est réglée sur Auto. Écran System Security (Sécurité du système) Élément de menu Description Intel AES-NI L'option Intel AES-In améliore la vitesse des applications en réalisant un cryptage et un décryptage à l'aide de l'ensemble des consignes liées à la norme de cryptage avancé, et est réglée sur Enabled (Activé) par défaut. System Password (Mot de passe du système) Vous permet de définir le mot de passe système. Cette option est réglée sur Enabled (Activé) par défaut et est en lecture seule si le cavalier de mot de passe n'est pas installé dans le système. Setup Password (Mot de passe de configuration) Vous permet de définir le mot de passe de configuration. Cette option est en lecture seule si le cavalier du mot de passe n'est pas installé sur le système. Password Status (État du mot de passe) Vous permet de verrouiller le mot de passe du système. Par défaut, l'option Password Status (État du mot de passe) est réglée sur Unlocked (Déverrouillé). TPM Security (Sécurité TPM) Vous permet de contrôler le mode de signalement du module TPM (Trusted Platform Module). Par défaut, l'option TPM Security est réglée sur Off (Désactivé). Vous ne pouvez modifier TPM Status (Condition TPM), TPM Activation (Activation de la puce TPM) et les champs Intel TXT que si le champ TPM Status (Condition TPM) est réglé sur On with Pre-boot Measurements (Activé avec les mesures de pré-amorçage) ou On without Pre-boot Measurements (Activé sans mesures pré-amorçage). TPM Activation (Activation de la puce TPM) Vous permet de modifier l'état opérationnel du module TPM. Par défaut, l'option TPM Activation (Activation de la puce TPM) est réglée sur No Change (Aucun changement). TPM Status (État TPM) Affiche la condition du module TPM. TPM Clear (Effacement TPM) PRÉCAUTION: L'effacement du module TPM entraîne une perte de toutes les clés du module TPM. La perte des clés du module TPM peut affecter le démarrage du système d'exploitation. Vous permet d'effacer tous les contenus du module TPM. Par défaut, l'option TPM Clear (Effacement TPM) est réglée sur No (Non). Intel TXT Vous permet d'activer ou de désactiver la technologie Intel Trusted Execution Technology. Pour activer Intel TXT, l'option Virtualization Technology (Technologie de virtualisation) doit être activée et l'option TPM Security (Sécurité TPM) doit être activée avec les mesures de pré-amorçage. Par défaut, l'option Intel TXT est réglée sur Off (Désactivé). BIOS Update Control (Contrôle de la mise à jour du BIOS) Vous permet de mettre à jour le BIOS en utilisant des utilitaires flash basés sur des environnements DOS ou UEFI. Pour les environnements ne nécessitant aucune mise à jour BIOS locale, il est recommandé de régler ce champ sur Limited (Limité). Par 29Élément de menu Description défaut, l'option Local BIOS Update Support (Prise en charge de la mise à jour du BIOS locale) est réglée sur Unlocked (Déverrouillé). REMARQUE: Les mises à jour du BIOS utilisant Dell Update Package ne sont pas concernées par cette option. Power Button (Bouton d'alimentation) Vous permet d'activer ou de désactiver le bouton d'alimentation sur l'avant du système. Par défaut l'option Power Button (Bouton d'alimentation) est réglée sur Enabled (Activé). NMI Button (Bouton INM) Vous permet d'activer ou de désactiver le bouton INM sur l'avant du système. Par défaut l'option NMI Button (Bouton INM) est réglée sur Enabled (Activé). AC Power Recovery Delay (Délai de restauration de l'alimentation) Vous permet de définir le temps de réaction du système une fois l'alimentation restaurée dans le système. Par défaut, l'option AC Power Recovery (Restauration de l'alimentation) est réglée sur Last (Dernière). AC Power Recovery Delay (Délai de restauration de l'alimentation secteur) Vous permet de régler la façon dont le système prend en charge le décalage de mise sous tension après que le courant alternatif soit restauré dans le système. Par défaut, l'option AC Power Recovery Delay (Délai de restauration du courant alternatif) est réglée sur Immediate (Immédiat). User Defined Delay (60s to 240s) (Délai défini de l'utilisateur [60 à 240]) Vous permet de régler le User Defined Delay (Délai défini de l'utilisateur) lorsque l'option User Defined (Utilisateur défini) pour le AC Power Recovery Delay (Délai de restauration du courant alternatif) est sélectionné. Paramètres divers Élément de menu Description System Time (Heure système) Vous permet de régler l'heure sur le système. System Date (Date système) Vous permet de régler la date sur le système. Asset Tag (Numéro d'inventaire) Affiche le numéro d'inventaire et vous permet de le modifier à des fins de sécurité et de suivi. Keyboard NumLock (Verr Num clavier) Vous permet de définir si le système démarre avec la fonction Verr Num activée ou désactivée. Par défaut, Keyboard NumLock (Verr Num clavier) est réglé sur On (Activé). REMARQUE: Ce champ ne s'applique pas aux claviers à 84 touches. Report Keyboard Errors (Signaler les erreurs de clavier) Vous permet de définir si les messages d'erreur de clavier sont signalés pendant le démarrage du système. Par défaut, le champ Report Keyboard Errors (Signaler les erreurs de clavier) est réglé sur Report (Signaler). F1/F2 Prompt on Error (Invite F1/F2 en cas d'erreur) Vous permet d'activer ou de désactiver l'invite F1/F2 en cas d'erreur. Par défaut, F1/F2 Prompt on Error (Invite F1/F2 en cas d'erreur) est réglé sur Enabled (Activé). In-System Characterization (Caractérisation dans le système) Ce champ permet d'activer ou de désactiver In-System Characterization (Caractérisation dans le système). Par défaut, In-System Characterization (Caractérisation dans le système) est réglé sur Enabled (Activé). 30Fonctionnalités de mot de passe du système et de mot de passe de configuration Vous pouvez créer un mot de passe du système et un mot de passe de configuration pour protéger le système. Pour activer la création du mot de passe du système et du mot de passe de configuration, le cavalier de mot de passe doit être activé. Pour obtenir plus d'informations sur les paramètres du cavalier du mot de passe, reportez-vous à la section Paramètres du cavalier de la carte système. System Password (Mot de passe du système) Il s'agit du mot de passe que vous devez saisir pour ouvrir une session sur le système. Setup Password (Mot de passe de configuration) Il s'agit du mot de passe que vous devez saisir pour accéder et effectuer les modifications sur les paramètres du BIOS ou UEFI de votre système. PRÉCAUTION: Les fonctionnalités de mot de passe assurent la sécurité de base des données de votre système. PRÉCAUTION: N'importe qui peut accéder aux données enregistrées sur votre système si celui-ci est en cours de fonctionnement et sans surveillance. REMARQUE: Votre système est fourni avec la fonction de mot de passe du système et de configuration désactivée. Attribution d'un mot de passe système et/ou de configuration REMARQUE: Le cavalier de mot de passe active ou désactive les fonctions de mot de passe du système et de mot de passe de configuration. Pour obtenir des informations sur les paramètres du cavalier de mot de passe, reportezvous à la section Paramètres du cavalier de la carte système. Vous pouvez attribuer un nouveau System Password (Mot de passe du système) et/ou Setup Password (Mot de passe de configuration) ou modifier un System Password (Mot de passe du système) et/ou un Setup Password (Mot de passe de configuration) déjà existant lorsque le paramètre du cavalier du mot de passe est activé et que l'option Password Status (État du mot de passe) est Unlocked (Déverrouillé). Si Password Status (État du mot de passe) est Locked (Verrouillé), vous ne pouvez pas modifier le mot de passe du système et/ou le mot de passe de configuration. Si le paramètre du cavalier du mot de passe est désactivé, le mot de passe du système et le mot de passe de configuration existants sont supprimés et vous n'avez pas besoin de fournir au système un mot de passe du système pour ouvrir une session. Attribution d'un mot de passe système et/ou de configuration : 1. Pour accéder à la configuration du système, appuyez immédiatement après le démarrage ou le redémarrage sur la touche . 2. Dans System Setup Main Menu (Menu principal de la configuration du système), sélectionnez System BIOS (BIOS du système) et appuyez sur . L'écran System BIOS (BIOS du système) s'affiche. 3. Dans l'écran System BIOS (BIOS du système), sélectionnez System Security (Sécurité du système) et appuyez sur . L'écran System Security (Sécurité du système) s'affiche. 4. Dans l'écran System Security (Sécurité du système), vérifiez que Password Status (État du mot de passe) est réglé sur Unlocked (Déverrouillé). 5. Sélectionnez System Password (Mot de passe du système), saisissez votre mot de passe du système, puis appuyez sur ou . Utilisez les consignes suivantes pour attribuer le mot de passe du système : 31– Un mot de passe peut contenir au maximum 32 caractères. – Le mot de passe peut contenir des chiffres allant de 0 à 9. – Seules les minuscules sont valides, les majuscules ne sont pas autorisées. – Les caractères spéciaux suivants sont autorisés : espace, (”), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`). Un message vous invite à ressaisir le mot de passe du système. 6. Saisissez à nouveau le mot de passe du système entré précédemment puis cliquez sur OK. 7. Sélectionnez Setup Password (Mot de passe de configuration), saisissez votre mot de passe du système, puis appuyez sur ou . Un message vous invite à ressaisir le mot de passe de configuration. 8. Saisissez à nouveau le mot de passe du de configuration entré précédemment puis cliquez sur OK. 9. Appuyez sur <Échap> pour retourner à l'écran de BIOS du système. Appuyez de nouveau sur <Échap>, et un message vous invite à enregistrer les modifications. REMARQUE: La protection par mot de passe ne prend effet que lorsque vous redémarrez le système. Suppression ou modification d'un mot de passe système et/ou de configuration existant Assurez-vous que le cavalier de mot de passe est activé et que Password Status (État du mot de passe) est réglé sur Unlocked (Déverrouillé) avant d'essayer de supprimer ou modifier le mot de passe du système et/ou de configuration. Vous ne pouvez pas supprimer ou modifier un mot de passe du système ou de configuration si Password Status (État du mot de passe) est réglé sur Locked (Verrouillé). Pour supprimer ou modifier le mot de passe du système et/ou de configuration : 1. Pour accéder à la configuration du système, appuyez immédiatement après le démarrage ou le redémarrage sur la touche . 2. Dans System Setup Main Menu (Menu principal de la configuration du système), sélectionnez System BIOS (BIOS du système) et appuyez sur . L'écran System BIOS (BIOS du système) s'affiche. 3. Dans l'écran System BIOS (BIOS du système), sélectionnez System Security (Sécurité du système) et appuyez sur . L'écran System Security (Sécurité du système) s'affiche. 4. Dans l'écran System Security (Sécurité du système), vérifiez que Password Status (État du mot de passe) est réglé sur Unlocked (Déverrouillé). 5. Sélectionnez System Password (Mot de passe du système), modifiez ou supprimer le mot de passe du système existant et appuyez sur ou . 6. Sélectionnez Setup Password (Mot de passe de configuration), modifiez ou supprimer le mot de passe de configuration existant et appuyez sur ou . REMARQUE: Si vous modifiez le mot de passe du système et/ou de configuration, un message vous invite à ressaisir le nouveau mot de passe. Si vous supprimer le mot de passe du système et/ou de configuration, un message vous invite à confirmer la suppression. 7. Appuyez sur <Échap> pour revenir à l'écran du BIOS du système. Appuyez de nouveau sur <Échap> pour faire apparaître une invite d'enregistrement des modifications. REMARQUE: Vous pouvez désactiver la sécurité du mot de passe tout en vous connectant au système. Pour ce faire, démarrez ou redémarrez le système, saisissez votre mot de passe puis appuyez sur . 32Protection du système à l'aide d'un mot de passe système REMARQUE: Si vous avez attribué un mot de passe de configuration, le système l'accepte également comme mot de passe du système alternatif. 1. Allumez ou redémarrez le système. 2. Saisissez le mot de passe, puis appuyez sur . Si Password Status (État du mot de passe) indique Locked (Verrouillé), vous devez saisir le mot de passe, puis appuyer sur lorsque le système vous y invite au redémarrage. Si un mot de passe du système incorrect est saisi, le système affiche un message et vous invite à saisir de nouveau votre mot de passe. Vous disposez de trois tentatives pour saisir le bon mot de passe. Après la troisième tentative infructueuse, le système affiche un message d'erreur indiquant que le système s'est arrêté et qu'il doit être éteint. Même après l'arrêt et le redémarrage du système, le message d'erreur continue à s'afficher tant que vous n'avez pas entré le mot de passe approprié. REMARQUE: Vous pouvez utiliser l'option Password Status (État du mot de passe) conjointement avec les options System Password (Mot de passe du système) et Setup Password (Mot de passe de configuration) pour mieux protéger le système contre toute modification non autorisée. Utilisation du système avec un mot de passe de configuration activé Si l'option Setup Password (Mot de passe de configuration) indique Enabled (Activé), saisissez ce mot de passe avant de modifier la plupart des options de configuration du système. Si vous ne saisissez pas le bon mot de passe au bout de trois tentatives, le système affiche le message Invalid Password! Number of unsuccessful password attempts: System Halted! Must power down. (Mot de passe incorrect ! Nombre d'essai Système arrêté ! Redémarrez le système.) Même après l'arrêt et le redémarrage du système, le message d'erreur continue à s'afficher tant que vous n'avez pas entré le mot de passe approprié. Les options suivantes font office d'exceptions : • Si l'option System Password (Mot de passe du système) n'est ni définie sur Enabled (Activé) ni verrouillée via l'option Password Status (État du mot de passe), vous pouvez attribuer un mot de passe du système. • Vous ne pouvez ni désactiver ni changer un mot de passe système existant. REMARQUE: Il est possible de combiner l'utilisation des options Password Status (État du mot de passe) et Setup Password (Mot de passe de configuration) pour empêcher toute modification non autorisée du mot de passe système. Accès au Gestionnaire d'amorçage UEFI REMARQUE: Les systèmes d'exploitation doivent être compatibles avec une version UEFI 64 bits (comme par exemple Microsoft Windows Server 2008 version x64) pour pouvoir être installés à partir du mode d'amorçage UEFI. L'installation des systèmes d'exploitation DOS et 32 bits est possible uniquement à partir du mode d'amorçage sur le BIOS. Le Gestionnaire d'amorçage permet d'effectuer les opérations suivantes : • Ajouter, supprimer et organiser les options d'amorçage • Accéder à la configuration du système et aux options d'amorçage BIOS sans nécessiter de redémarrage 33Pour accéder au Gestionnaire d'amorçage : 1. Allumez ou redémarrez le système. 2. Appuyez sur dès l'apparition du message suivant : = UEFI Boot Manager (Gestionnaire d'amorçage UEFI) Si le système d'exploitation commence à se charger alors que vous n'avez pas encore appuyé sur , attendez que le système finisse de démarrer, puis redémarrez-le et réessayez. Utilisation des touches de navigation du Gestionnaire d'amorçage Touche Description Flèche vers le haut Permet de revenir au champ précédent. Flèche vers le bas Permet de passer au champ suivant. Vous permet de saisir une valeur dans le champ sélectionné (le cas échéant) ou de suivre le lien dans le champ. Barre d'espacement Permet d'étendre ou de réduire la liste déroulante, le cas échéant. Passe à l'objectif suivant. REMARQUE: Pour le navigateur de graphiques standard seulement. <Échap> Passe à la page précédente jusqu'à ce que vous aperceviez l'écran principal. En appuyant sur la touche <Échap> dans l'écran principal, vous quitterez le gestionnaire d'amorçage et démarrerez le système. Permet d'afficher le fichier d'aide de la configuration du système. REMARQUE: Pour la plupart des options, les modifications effectuées sont enregistrées mais ne prennent effet qu'au redémarrage du système. Écran Boot Manager (Gestionnaire d'amorçage) Élément de menu Description Continue Normal Boot (Poursuivre le démarrage normal) Le système tente d'effectuer successivement l'amorçage sur différents périphériques en commençant par le premier dans l'ordre d'amorçage. En cas d'échec de l'amorçage, le système passe au périphérique suivant dans l'ordre d'amorçage jusqu'à ce que le démarrage réussisse ou qu'aucune autre option ne soit disponible. Menu BIOS Boot (Amorçage BIOS) Affiche la liste des options d'amorçage BIOS disponibles (marquées par des astérisques). Choisissez l'option d'amorçage de votre choix, puis appuyez sur . Menu UEFI Boot (Amorçage UEFI) Affiche la liste des options d'amorçage UEFI disponibles (marquées par des astérisques). Choisissez l'option d'amorçage de votre choix, puis appuyez sur . Le menu UEFI Boot (Amorçage UEFI) vous permet d'utiliser les options suivantes : Add Boot Option (Ajouter une option d'amorçage), Delete Boot Option (Supprimer une option d'amorçage) ou Boot From File (Amorçage à partir d'un fichier). 34Élément de menu Description Menu Driver Health (Intégrité du pilote) Affiche une liste des pilotes installés sur le système ainsi que leur état d'intégrité. Launch System Setup (Démarrer la configuration du système) Vous permet d'accéder au programme de configuration du système. System Utilities (Utilitaires du système) Vous permet d'accéder à l'explorateur de fichier de mise à jour du BIOS, d'exécuter le programme Dell Diagnostics et de redémarrer le système. Menu UEFI Boot (Amorçage UEFI) Élément de menu Description Select UEFI Boot Option (Sélectionner une option d'amorçage UEFI) Affiche la liste des options d'amorçage UEFI disponibles (marquées par des astérisques), choisissez l'option d'amorçage de votre choix, puis appuyez sur . Add Boot Option (Ajouter une option d'amorçage) Ajoute une nouvelle option d'amorçage. Delete Boot Option (Supprimer une option d'amorçage) Supprime une option d'amorçage existante. Boot From File (Amorçage à partir d'un fichier) Définit une option d'amorçage utilisable une seule fois qui ne figure pas dans la liste des options d'amorçage. Gestion intégrée du système Le Dell Lifecycle Controller offre une gestion avancée des systèmes intégrés tout au long du cycle de vie du serveur. Le Lifecycle Controller peut être démarré pendant la séquence d'amorçage et peut fonctionner indépendamment du système d'exploitation. REMARQUE: Certaines configurations de plate-forme peuvent ne pas prendre en charge l'ensemble des fonctionnalités de Lifecycle Controller. Pour plus d'informations sur la configuration de Lifecycle Controller, la configuration du matériel et du micrologiciel et le déploiement du système d'exploitation, reportez-vous à la documentation relative à Lifecycle Controller, disponible à l'adresse support.dell.com/manuals. Utilitaire de configuration iDRAC L'utilitaire de configuration iDRAC est une interface permettant d'installer et de configurer les paramètres iDRAC à l'aide de UEFI. Vous pouvez activer ou désactiver de nombreux paramètres iDRAC à l'aide de l'utilitaire de configuration iDRAC7. REMARQUE: L'accès à certaines fonctions de l'utilitaire de configuration iDRAC exige la mise à niveau de la licence iDRAC7 Enterprise. Pour en savoir plus sur l'utilisation d'iDRAC, reportez-vous à la section iDRAC7 User's Guide (Guide de l'utilisateur iDRAC7) sous Software → Systems Management → Dell Remote Access Controllers (Logiciel, Gestion des systèmes, Contrôleurs d'accès à distance DELL) à l'adresse suivante : support.dell.com/manuals. 35Accès à l'utilitaire de configuration iDRAC 1. Activez ou redémarrez le système géré. 2. Appuyez sur pendant l'auto-test de démarrage (POST). 3. Sur la page System Setup Main Menu (Menu principal du système de configuration), cliquez sur iDRAC Settings (Paramètres iDRAC). La page iDRAC Settings (Paramètres iDRAC) s'affiche. 363 Installation des composants du système Outils recommandés Vous pouvez avoir besoin des outils suivants pour réaliser les procédures décrites dans cette section : • Clé du verrouillage à clé du système • Tournevis cruciformes n°1 et n°2 • Tournevis à pointe à six lobes T10 et T15 • Bracelet de mise à la masse connecté au sol Les outils suivants sont requis pour l'assemblage de câbles d'alimentation en CC (unité d'alimentation), s'ils sont disponibles : • Pince à dénuder pouvant supprimer une isolation de calibre10 AWG solide ou toronnée, fil de cuivre isolé • Pince à sertir manuelle AMP 90871-1 ou un outil équivalent REMARQUE: Utilisez une pièce fil alpha numéro 3080 ou une pièce équivalente (câblage 65/30). Cadre avant (en option) Retrait du cadre avant 1. Ouvrez le verrou situé à l'extrémité gauche du cadre. 2. Soulevez le loquet d'éjection situé près du verrou. 3. Faites pivoter l'extrémité gauche du cadre pour écarter celui-ci du panneau avant. 4. Décrochez la partie droite du cadre et retirez le cadre. Figure 8. Retrait et installation du cadre avant 371. loquet 2. verrou 3. cadre avant 4. crochet de verrouillage Installation du cadre avant 1. Accrochez l'extrémité droite du cadre au châssis. 2. Fixez l'extrémité libre du cadre sur le système. 3. Fixez le cadre à l'aide du verrouillage à clé. Ouverture et fermeture du système AVERTISSEMENT: Chaque fois que vous devez soulever le système, demandez de l'aide. Pour éviter les blessures, ne tentez pas de soulever le système par vous-même. AVERTISSEMENT: Ouvrir ou retirer le capot du système lorsque celui-ci est sous tension est dangereux. Vous risqueriez de recevoir une décharge électrique. PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Ne pas faire fonctionner le système sans le capot pour une durée dépassant cinq minutes. Ouverture du système REMARQUE: L'utilisation systématique d'un tapis et d'un bracelet antistatiques est recommandée pour manipuler les composants internes du système. 1. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 2. Faites pivoter le verrou du loquet de fermeture dans le sens inverse des aiguilles d'une montre afin de le mettre en position déverrouillée. 3. Soulevez le loquet situé sur la partie supérieure du système, puis faites glisser le capot vers l'arrière. 4. Saisissez le capot de chaque côté, puis soulevez-le avec précaution pour le retirer du système. 38Figure 9. Ouverture et fermeture du système 1. capot du système 2. loquet 3. verrou du loquet de dégagement Fermeture du système 1. Relevez le loquet situé sur le capot. 2. Placez le capot sur le châssis et décalez-le légèrement vers l'arrière pour le dégager des crochets du châssis, de sorte qu'il repose totalement à plat sur ce dernier. 3. Rabattez le loquet pour faire pivoter le capot en position fermée. 4. Tournez le verrou du loquet de dégagement dans le sens des aiguilles d'une montre pour fermer le capot. 5. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. À l'intérieur du système PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Les composants remplaçables à chaud sont indiqués en orange et les ergots sur les composants sont indiqués en bleu. 39Figure 10. À l'intérieur du système 1. assemblage du panneau de commande 2. pince de fixation de câble 3. ventilateurs de refroidissement (7) 4. support de fixation de câble 5. Carénage de refroidissement 6. Blocs d'alimentation (2) 7. Le commutateur d'intrusion dans le châssis 8. carte de montage 3 9. Carte fille réseau 10. carte de montage 2 11. carte contrôleur de stockage intégrée 12. carénage de refroidissement de la carte fille réseau 13. barrettes DIMM (24) 14. Dissipateur de chaleur du processeur 2 15. Fond de panier des disques durs 16. Panneau de commande 17. Disques durs (4) 18. le lecteur optique Carénage de refroidissement Retrait du carénage de refroidissement PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Ne mettez jamais le système sous tension sans le carénage de refroidissement. Le système peut surchauffer rapidement entraînant sa mise hors tension ainsi qu'une perte de données. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 403. Saisissez les ergots, puis soulevez le carénage de refroidissement du système. Figure 11. Installation et retrait du carénage de refroidissement 1. carénage de refroidissement Installation du carénage de refroidissement PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Pour le positionnement correct du carénage de refroidissement dans le châssis, assurez-vous que les câbles qui se trouvent à l'intérieur du système sont acheminés le long de la paroi du châssis et qu'ils sont bien attachés avec le support de fixation de câble. 1. Alignez les pattes du carénage de refroidissement sur les fentes de fixation du châssis. 2. Baissez le carénage de refroidissement dans le châssis jusqu'à ce qu'il soit fermement positionné. 3. Le cas échéant, remplacez la carte PCle pleine longueur. 4. Refermez le système. 5. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Mémoire système Votre système prend en charge des barettes de mémoire ECC sans tampon DDR3 (UDIMM ECC), des barettes de mémoire enregistrées (RDIMM) et des barettes de mémoire de charge réduite (LRDIMM). Il prend en charge les spécifications de tension DDR3 et DDR3L. REMARQUE: MT/s indique la vitesse de la barrette DIMM en méga-transferts par seconde. La fréquence de fonctionnement de bus mémoire peut être de 1 600 MT/s, 1 333 MT/s, 1 066 MT/s ou 800 MT/s selon : • le type de barette de mémoire (UDIMM, RDIMM ou LRDIMM) • la configuration de la barrette DIMM (nombre de rangées) • la fréquence maximale des barrettes DIMM • le nombre de barrettes installées par canal 41• la tension de fonctionnement de la barrette DIMM • le profil système sélectionné (par exemple, Performance Optimized [Performance optimisée], Custom [Personnalisé] ou Dense Configuration Optimized [Configuration dense optimisée]) • la fréquence maximale de la barrette DIMM prise en charge des processeurs Le système est composé de 24 supports de mémoire divisés en deux ensembles de 12 supports, un ensemble par processeur. Chaque ensemble est organisé en 4 canaux. Dans chaque canal, les leviers d'éjection du premier support sont blancs, ceux du second support sont noirs et ceux du troisième support sont verts. REMARQUE: Les barrettes DIMM des supports A1 à A12 sont attribuées au processeur 1 et les barrettes DIMM des supports B1 à B12 sont attribuées au processeur 2. Figure 12. Emplacement des supports de mémoire Les canaux de mémoire sont répartis comme suit : 42Processeur 1 canal 0 : logements A1, A5 et A9 canal 1 : logements A2, A6 et A10 canal 2 : logements A3, A7 et A11 canal 3 : logements A4, A8 et A12 Processeur 2 canal 0 : logements B1, B5 et B9 canal 1 : logements B2, B6 et B10 canal 2 : logements B3, B7 et B11 canal 3 : logements B4, B8 et B12 Le tableau suivant présente les installations de mémoire et les fréquences de fonctionnement pour les configurations prises en charge. Type de barrette de mémoire Barrettes installées/canal Fréquence de fonctionnement (en MT/s) Rangées de barrettes DIMM maximales/canal 1,5 V 1,35 V ECC UDIMM 1 1 333, 1 066 et 800 1 066 et 800 Double rangée 2 1 333, 1 066 et 800 1 066 et 800 Double rangée Barrette RDIMM 1 1 333, 1 066 et 800 1 333, 1 066 et 800 Double rangée 1 066 et 800 800 À quatre rangées 2 1 600, 1 333, 1 066 et 800 1 333, 1 066 et 800 Double rangée 800 800 À quatre rangées 3 1 066 et 800 Non applicable Double rangée LRDIMM 1 1 333 et 1 066 1 333 et 1 066 À quatre rangées 2 1 333 et 1 066 1 333 et 1 066 À quatre rangées 3 1 066 1 066 À quatre rangées Consignes générales pour l'installation des barrettes de mémoire Ce système prend en charge la configuration de mémoire flexible, permettant une configuration et une exécution du système depuis n'importe quelle configuration architecturale d'un jeu de puces valide. Ci-dessous se trouvent les consignes recommandées pour obtenir des performances optimales : • Les UDIMM, les RDIMM et les LRDIMM ne doivent pas être mélangés. • Les barrettes DIMM DRAM x4 et x8 peuvent être mélangées. Pour obtenir plus d'informations, reportez-vous aux consignes spécifiques à chaque mode. • Deux barrettes UDIMM peuvent être installées dans un canal. • Jusqu'à deux RDIMM à quatre rangées et jusqu'à trois RDIMM à rangées doubles ou individuelles peuvent être remplies par canal. Lorsqu'une RDIMM à quatre rangées est remplie dans le premier logement avec des leviers de dégagement blancs, il est impossible de remplir le troisième logement de barette de mémoire dans le canal avec des leviers de dégagement verts. • Jusqu'à trois LRDIMM peuvent être remplis quel que soit le nombre de rangées. • Remplissez les supports de barrettes DIMM uniquement si un processeur est installé. Pour les systèmes à processeur unique, les supports A1 à A12 sont disponibles. Pour les systèmes à double processeur, les supports A1 à A12 et les supports B1 à B12 sont disponibles. 43• Remplissez tous les supports avec les pattes de dégagement blanches en premier, puis les pattes noires et enfin les vertes. • Ne remplissez pas le troisième support de barrettes de mémoire DIMM dans un canal avec des pattes de dégagement vertes si une barrette de mémoire RDIMM à quatre rangées se trouve dans le premier support avec les pattes de dégagement blanches. • Remplissez les supports par le nombre de rangées le plus élevé dans l'ordre suivant : tout d'abord les supports avec les pattes de dégagement blanches, puis les noires et enfin les vertes. Par exemple, si vous souhaitez mélanger des barrettes DIMM à quatre rangées et à double rangée, installez les barrettes DIMM à quatre rangées dans les supports avec pattes de dégagement blanches et les barrettes à double rangée dans les supports avec pattes de dégagement noires. • Dans une configuration à deux processeurs, la configuration de la mémoire pour chaque processeur doit être identique. Par exemple, si vous remplissez le support A1 pour le processeur 1, vous devez alors remplir le support B1 pour le processeur 2, etc. • Des barrettes de mémoire de différentes tailles peuvent être mélangées tant que les autres règles de population de mémoire sont respectées (par exemple, les barrettes de mémoire de 2 Go et de 4 Go peuvent être mélangées). • Installez quatre barrettes DIMM par processeur (une barrette DIMM par canal) à la fois pour maximiser les performances. • Si les barrettes de mémoire avec différentes vitesses sont installées, elles fonctionneront à la vitesse de la/des barrette(s) de mémoire installée(s) la/les plus lente(s) ou plus lentement selon la configuration des barrettes DIMM sur le système. Consignes spécifiques à chaque mode Quatre canaux de mémoire sont attribués à chaque processeur. Les configurations autorisées dépendent du mode de mémoire sélectionné. REMARQUE: Les barrettes DIMM DRAM de largeur x4 et x8 peuvent être mélangées pour offrir une prise en charge des fonctionnalités RAS. Toutefois, toutes les recommandations pour des fonctionnalités RAS spécifiques doivent être respectées. Les barrettes DIMM DRAM de largeur x4 conservent la correction SDDC (Single Device Data Correction) dans le mode d'optimisation de la mémoire (canal indépendant). Les barrettes DIMM DRAM de largeur x8 nécessitent le mode Fonctions ECC avancées pour profiter de la correction SDDC. Les sections suivantes offrent des recommandations supplémentaires relatives au remplissage de logements pour chaque mode. Advanced ECC (Lockstep) [Fonctions ECC avancées (Lockstep)] Le mode Advanced ECC (Fonctions avancées) permet d'étendre la SDDC des barrettes DIMM DRAM de largeur x4 aux DRAM de largeur x4 et x8. Ce mode permet de protéger le système contre les échecs de puce DRAM seule au cours du fonctionnement normal. Consignes d'installation de la mémoire : • Les barrettes doivent être de taille, de vitesse et de technologie identiques. • Les barrettes DIMM installées dans les supports de mémoire avec les pattes de dégagement blanches doivent être identiques et les mêmes règles s'appliquent pour les supports avec des pattes de dégagement noires et vertes. Cela assure que des barrettes DIMM identiques sont installées par paires identiques, par exemple, A1 avec A2, A3 avec A4, A5 avec A6, etc. REMARQUE: Les fonctions ECC avancées avec mise en miroir ne sont pas prises en charge. Mode Optimisation de la mémoire (canal indépendant) Ce mode prend en charge la SDDC uniquement pour les barrettes de mémoire qui utilisent une largeur de périphérique x4 et qui n'imposent aucune exigence spécifique relative à la population d'emplacements. 44Mémoire de réserve REMARQUE: Afin d'utiliser la mémoire de réserve, cette fonction doit être activée dans la configuration du système. Dans ce mode, une rangée par canal est réservée. Dans le cas où des erreurs corrigeables persistantes sont détectées sur une rangée, les données de cette rangée sont copiées sur la rangée de réserve et la rangée défaillante est désactivée. Lorsque la mémoire de réserve est activée, la mémoire système disponible pour le système d'exploitation est réduite d'une rangée par canal. Par exemple, pour une configuration bi-processeur avec seize barrettes DIMM à double rangée de 4 Go, la mémoire système disponible est : 3/4 (rangées/canal) × 16 (barrettes DIMM) × 4 Go = 48 Go et non 16 (barrettes DIMM) × 4 Go = 64 Go. REMARQUE: La mémoire de réserve n'offre aucune protection contre une erreur non corrigeable sur plusieurs bits. REMARQUE: Les modes Fonctions ECC avancées/Lockstep et Optimisation prennent en charge la mémoire de réserve. Mise en miroir de la mémoire La mise en miroir de la mémoire offre le mode disposant de la plus forte fiabilité des barrettes DIMM comparativement aux autres modes. En effet, il offre une protection contre les incidents non corrigeables sur plusieurs bits. Dans une configuration mise en miroir, la mémoire système totale disponible correspond à la moitié du total de la mémoire physique installée. La moitié de la mémoire installée est utilisée pour mettre en miroir les barrettes DIMM actives. Dans le cas d'une erreur non corrigeable, le système bascule sur la copie mis en miroir. Cela garantie la SDDC et la protection sur plusieurs bits. Consignes d'installation de la mémoire : • Les barrettes doivent être de taille, de vitesse et de technologie identiques. • Les barrettes DIMM installées dans les supports de mémoire avec les pattes de dégagement blanches doivent être identiques et les mêmes règles s'appliquent pour les supports avec des pattes de dégagement noires et vertes. Cela assure que des barrettes DIMM identiques sont installées par paires identiques, par exemple, A1 avec A2, A3 avec A4, A5 avec A6, etc. Exemples de configurations de mémoire Les tableaux suivants montrent des exemples de configurations de mémoire pour un et deux processeurs qui suivent les consignes de mémoire appropriées indiquées dans cette section. REMARQUE: Les barrettes RDIMM à quatre rangées de 16 Go ne sont pas prises en charge. REMARQUE: 1R, 2R et 4R qui se trouvent dans le tableau suivant indiquent respectivement des barettes de mémoire à une, deux et quatre rangées. Tableau 1. Configurations de mémoire—Processeur individuel Capacité du système (en Go) Taille des barrettes de mémoire DIMM (en Go) Nombre de barrettes de mémoire DIMM Rangée de barette de mémoire, organisation, et fréquence Population de l'emplacement de la barrette de mémoire DIMM 2 2 1 1R x8, 1 333 MT/s 1R x8, 1 600 MT/s A1 4 2 2 1R x8, 1 333 MT/s 1R x8, 1 600 MT/s A1, A3 45Capacité du système (en Go) Taille des barrettes de mémoire DIMM (en Go) Nombre de barrettes de mémoire DIMM Rangée de barette de mémoire, organisation, et fréquence Population de l'emplacement de la barrette de mémoire DIMM 8 2 4 1R x8, 1 333 MT/s 1R x8, 1 600 MT/s A1, A2, A3, A4 12 2 6 1R x8, 1 333 MT/s 1R x8, 1 600 MT/s A1, A2, A3, A4, A5, A6 16 2 8 1R x8, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8 4 4 2R x8, 1 333 MT/s 2R x8, 1 600 MT/s A1, A2, A3, A4 24 2 12 1R x8, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 4 6 2R x8, 1 333 MT/s 2R x8, 1 600 MT/s A1, A2, A3, A4, A5, A6 48 4 12 2R x8, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 8 6 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4, A5, A6 96 8 12 2R x4, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 16 6 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4, A5, A6 128 16 8 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4, A5, A6, A7, A8 144 16 et 8 10 2R x4, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 REMARQUE: Des barrettes DIMM de 16 Go doivent être installées dans les emplacements numérotés A1, A2, A3, A4, A5, A6, A7 et A8 et des barrettes DIMM de 8 Go doivent être installées dans les emplacements A9 et A11. 384 32 12 LRDIMM, x4, 1333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 Tableau 2. Configurations de mémoire— Deux processeurs Capacité du système (en Go) Taille des barrettes de mémoire DIMM (en Go) Nombre de barrettes de mémoire DIMM Rangée de barettes de mémoire, organisation, et fréquence Population de l'emplacement de la barrette de mémoire DIMM 16 2 8 1R x8, 1 333 MT/s 1R x8, 1 600 MT/s A1, A2, A3, A4 B1, B2, B3, B4 32 2 16 1R x8, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8 46Capacité du système (en Go) Taille des barrettes de mémoire DIMM (en Go) Nombre de barrettes de mémoire DIMM Rangée de barettes de mémoire, organisation, et fréquence Population de l'emplacement de la barrette de mémoire DIMM B1, B2, B3, B4, B5, B6, B7, B8 32 4 8 2R x8, 1 333 MT/s 2R x8, 1 600 MT/s A1, A2, A3, A4 B1, B2, B3, B4 64 4 16 2R x8, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8 B1, B2, B3, B4, B5, B6, B7, B8 8 8 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4 B1, B2, B3, B4 96 4 24 2R x8, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12 8 12 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4, A5, A6 B1, B2, B3, B4, B5, B6 128 8 16 2R x4, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8 B1, B2, B3, B4, B5, B6, B7, B8 16 8 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4, B1, B2, B3, B4 160 8 20 2R x4, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12 16 et 8 12 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4, A5, A6 B1, B2, B3, B4, B5, B6 REMARQUE: Des barrettes DIMM de 16 Go doivent être installées dans les emplacements numérotés A1, A2, A3, A4, B1, B2, B3 et B4 et des barrettes DIMM de 8 Go doivent être installées dans les emplacements A5, A6, B5 et B6. 192 8 24 2R x4, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12 16 12 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4, A5, A6 B1, B2, B3, B4, B5, B6 256 16 16 2R x4, 1 333 MT/s 2R x4, 1 600 MT/s A1, A2, A3, A4, A5, A6, A7, A8 B1, B2, B3, B4, B5, B6, B7, B8 384 16 24 2R x4, 1 333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 47Capacité du système (en Go) Taille des barrettes de mémoire DIMM (en Go) Nombre de barrettes de mémoire DIMM Rangée de barettes de mémoire, organisation, et fréquence Population de l'emplacement de la barrette de mémoire DIMM B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12 32 12 4R, x4, 1333 MT/s A1, A2, A3, A4, A5, A6 B1, B2, B3, B4, B5, B6 512 32 16 4R, x4, 1066 MT/s 4R, x4, 1333 MT/s A1, A2, A3, A4, A5, A6, A7, A8 B1, B2, B3, B4, B5, B6, B7, B8 768 32 24 LRDIMM, x4, 1333 MT/s A1, A2, A3, A4, A5, A6, A7, A8, A9, A10, A11, A12 B1, B2, B3, B4, B5, B6, B7, B8, B9, B10, B11, B12 Retrait de barrettes de mémoire AVERTISSEMENT: Les barrettes de mémoire restent chaudes au toucher quelques temps après l'arrêt du système. Laissez refroidir les barrettes avant de les manipuler. Manipulez les barrettes par les bords de la carte et évitez de toucher leurs composants. PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Pour assurer le bon refroidissement du système, des barrettes neutres doivent être installées dans tout logement de barrette inoccupé. Retirez les barrettes neutres uniquement si vous avez l'intention d'utiliser des barrettes de mémoire dans ces logements. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Retirez le carénage de refroidissement. 4. Localisez le(s) support(s) de barrettes de mémoire appropriés. PRÉCAUTION: Tenez chaque barrette par les bords, en veillant à ne pas toucher la partie centrale. 5. Exercez une pression vers le bas puis vers l'extérieur sur les dispositifs d'éjection situés de part et d'autre de l'emplacement, afin d'extraire la barrette de mémoire. 48Figure 13. Retrait et installation d'une barrette de mémoire 1. module de mémoire 2. dispositifs d'éjection du support pour barrette de mémoire (2) 3. détrompeur 6. Installez les caches du module de mémoire dans le ou les supports du module de mémoire vides afin de garantir le refroidissement correct du système. 7. Installez le carénage de ventilation. 8. Refermez le système. 9. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Installation de barrettes de mémoire AVERTISSEMENT: Les barrettes de mémoire restent chaudes au toucher quelques temps après l'arrêt du système. Laissez refroidir les barrettes avant de les manipuler. Manipulez les barrettes par les bords de la carte et évitez de toucher leurs composants. PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Pour assurer le bon refroidissement du système, des barrettes neutres doivent être installées dans tout logement de barrette inoccupé. Retirez les barrettes neutres uniquement si vous avez l'intention d'utiliser des barrettes de mémoire dans ces logements. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Retirez le carénage de refroidissement. 494. Identifiez les supports de barrettes de mémoire. 5. Appuyez sur les éjecteurs qui se trouvent sur le support du module de mémoire et relâchez-les afin de permettre au module de mémoire de s'insérer dans le support. Si un cache de module de mémoire est installé dans le support, enlevez-le. REMARQUE: Conservez le ou les caches de module de mémoire pour une utilisation ultérieure. PRÉCAUTION: Tenez chaque barrette par les bords, en veillant à ne pas toucher la partie centrale. 6. Alignez le connecteur de bord de la barrette de mémoire sur le repère du support, puis insérez la barrette dans le support. REMARQUE: Le détrompeur du logement de la barrette mémoire permet de garantir que la barrette est insérée dans le bon sens. 7. Appuyez sur la barrette de mémoire avec les pouces jusqu'à verrouillage du loquet des leviers du support. Si la barrette de mémoire est installée correctement, les leviers s'alignent sur ceux des autres connecteurs équipés de barrettes. 8. Répétez les étapes 4 à 7 de cette procédure pour installer les barrettes de mémoire restantes. 9. Réinstallez le carénage de refroidissement. 10. Refermez le système. 11. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 12. Appuyez sur pour accéder à la Configuration système, puis vérifiez les paramètres de la mémoire. Le système doit normalement avoir déjà modifié la valeur pour prendre en compte la mémoire qui vient d'être installée. 13. Si la valeur est incorrecte, un ou plusieurs module de mémoire peuvent ne pas être installés correctement. Répétez les étapes 4 à 7 de cette procédure, en vous assurant bien que les modules de mémoire sont fermement positionnés dans leurs supports. 14. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Disques durs Tous les disques durs se connectent à la carte système en passant par le fond de panier du disque dur. Les disques durs sont approvisionnés en transporteurs de disques durs échangeables à chaud qui correspondent aux logements de disque dur. PRÉCAUTION: Avant de retirer ou d'installer un lecteur pendant que le système est en cours de fonctionnement, reportez-vous à la documentation relative à la carte contrôleur de stockage pour vérifier que la configuration de l'adaptateur hôte lui permet de prendre en charge le retrait et l'insertion de lecteurs à chaud. PRÉCAUTION: N'éteignez pas votre système et ne le redémarrez pas pendant que le disque dur est en train de se formater. Cela pourrait causer une panne du disque dur. REMARQUE: Utilisez uniquement des disques durs testés et homologués pour l'utilisation avec le fond de panier de disque dur. Lorsque vous formatez un disque dur, prévoyez assez de temps pour terminer le formatage. Souvenez-vous que des disques durs à capacité élevée peuvent prendre des heures pour se formater. 50Retrait d'un cache de lecteur de disque dur de 2,5 pouces PRÉCAUTION: Pour assurer un refroidissement correct du système, vous devez installer un cache de disque dur dans toutes les baies de disque dur vacantes. 1. Retirez le cadre avant s'il est installé. 2. Appuyez sur le bouton de dégagement et extrayez le cache hors du logement de disque. Figure 14. Retrait et installation d'un cache de lecteur de disque dur de 2,5 pouces 1. cache de disque dur 2. bouton de dégagement Installation d'un cache de lecteur de disque dur de 2,5 pouces 1. Retirez le cadre avant s'il est installé. 2. Insérez le cache de disque dur dans le logement de disque dur jusqu'à ce que le bouton de dégagement s'enclenche. 3. Le cas échéant, installez le cadre avant. Retrait d'un disque dur remplaçable à chaud PRÉCAUTION: Pour éviter toute perte de données, veillez à ce que le remplacement de lecteurs à chaud soit pris en charge. Consultez la documentation fournie avec le système d'exploitation. 1. À partir du logiciel de gestion, préparez le retrait du disque dur. Attendez que les indicateurs du support de disque dur signalent qu'il peut être retiré en toute sécurité. Pour de plus amples informations, consultez la documentation du contrôleur de stockage. Si le disque dur est en ligne, l'indicateur d'activité/de panne clignote en vert lorsque le disque dur est mis hors tension. Une fois les indicateurs du disque dur éteints, celui-ci est prêt à être retiré. 2. Appuyez sur le bouton de dégagement pour ouvrir la poignée de dégagement du support du disque. 3. Retirez le support de disque dur de la baie de disque. PRÉCAUTION: Pour assurer un refroidissement correct du système, vous devez installer un cache de disque dur dans toutes les baies de disque dur vacantes. 514. Insérez un cache de lecteur dans la baie de disque dur vacante. Figure 15. Retrait et installation d'un disque dur remplaçable à chaud 1. bouton de dégagement 2. disque dur 3. poignée du support de disque dur Installation d'un disque dur remplaçable à chaud PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Utilisez uniquement des disques durs testés et homologués pour l'utilisation avec le fond de panier de disque dur. PRÉCAUTION: La prise en charge de la combinaison lecteurs SAS et SATA dans le même volume RAID n'est pas assurée. PRÉCAUTION: Lors de l'installation d'un disque dur, assurez-vous que les lecteurs adjacents sont pleinement installés. Si vous essayez d'insérer un support de disque dur et de verrouiller sa poignée en regard d'un support partiellement installé, vous risquez d'endommager le ressort du carénage du support partiellement installé et de le rendre inutilisable. PRÉCAUTION: Pour éviter toute perte de données, veillez à ce que le remplacement de lecteurs à chaud soit pris en charge. Consultez la documentation fournie avec le système d'exploitation. PRÉCAUTION: Lorsqu'un disque dur remplaçable à chaud est installé et que le système est mis sous tension, le disque dur commence automatiquement à se reconstruire. Veillez strictement à ce que le disque dur de remplacement soit vierge ou contienne des données que vous souhaitez écraser. Les éventuelles données présentes sur le disque dur de remplacement sont immédiatement perdues après l'installation du disque. 1. Si un cache de disque dur est installé dans le logement de disque dur, retirez-le. 2. Installez le disque dur dans le support de disque dur. 3. Appuyez sur le bouton de dégagement situé à l'avant du support de disque dur puis tournez la poignée. 524. Insérez le support de disque dur dans le logement de disque dur jusqu'à ce que le support se connecte au fond de panier. 5. Fermez la poignée du support de disque dur afin de verrouiller le lecteur. Retrait d'un disque dur installé dans un support 1. Retirez les vis des rails coulissants du support de disque dur. 2. Soulevez le disque dur et retirez-le de son support. Figure 16. Retrait et installation d'un disque dur dans un support 1. support de disque dur 2. disque dur 3. vis (4) Installation d'un disque dur dans un support PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Insérez le disque dur dans le support, connecteur vers l'arrière. 2. Alignez les trous de vis du disque dur sur ceux de l'arrière du support. Si la position est correcte, l'arrière du disque dur s'aligne sur l'arrière du support. 3. Fixez le disque dur sur le support à l'aide des vis. 53Optical Drive (Lecteur optique) Retrait du lecteur optique PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Cette procédure s'applique seulement au système 8 disques durs. 1. Retirez le cadre avant s'il est installé. 2. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 3. Ouvrez le système. 4. Débranchez le câble d'alimentation/de données situé à l'arrière du lecteur. Prenez note de l'acheminement des câbles de données/d'alimentation sur le côté du système lorsque vous les retirez de la carte système et du lecteur. Vous devez les réacheminer correctement lorsque vous les réinstallez pour éviter qu'ils ne soient pincés ou écrasés. 5. Pour retirer le lecteur, appuyez et poussez la patte de dégagement bleue vers l'avant du système. 6. Extrayez le lecteur optique en le faisant glisser hors de la baie. 7. Si vous n'envisagez pas d'installer un nouveau lecteur optique, installez un cache. 8. Refermez le système. 9. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 10. Le cas échéant, installez le cadre avant. Figure 17. Retrait et installation du lecteur optique 541. lecteur optique 2. câble d'alimentation et de données 3. languette de dégagement Installation du lecteur optique PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Cette procédure s'applique seulement au système 8 disques durs. 1. Retirez le cadre avant s'il est installé. 2. Éteignez le système et les périphériques connectés, puis débranchez le système de la prise de courant. 3. Ouvrez le système. 4. Alignez le lecteur optique avec l'emplacement du lecteur optique situé à l'avant du châssis. 5. Insérez le lecteur optique jusqu'à ce que le loquet s'enclenche. 6. Connectez le câble d'alimentation/de données au lecteur optique et à la carte système. REMARQUE: Vous devez acheminer correctement le câble sur le côté du système pour éviter qu'il ne soit coincé ou écrasé. 7. Refermez le système. 8. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 9. Le cas échéant, installez le cadre avant. Ventilateurs de refroidissement Votre système prend en charge les ventilateurs de refroidissement remplaçables à chaud. REMARQUE: En cas de problème dû à un ventilateur spécifique, le logiciel de gestion du système référence les numéros de ventilateur. Ceci facilite l'identification et le remplacement d'un ventilateur défectueux au sein du module de ventilation. Retrait d'un ventilateur AVERTISSEMENT: Ouvrir ou retirer le capot du système lorsque celui-ci est sous tension est dangereux. Vous risqueriez de recevoir une décharge électrique. Manipulez avec précaution les ventilateurs lorsque vous les retirez ou les installez. PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Les ventilateurs sont remplaçables à chaud. Pour maintenir un refroidissement adéquat lorsque le système est sous tension, remplacez les ventilateurs un par un. 55PRÉCAUTION: Ne faites pas fonctionner le système lorsque son capot est retiré pendant plus de 5 minutes. REMARQUE: La procédure de retrait pour chaque ventilateur est identique. 1. Ouvrez le système. 2. Saisissez le ventilateur et retirez-le du système. Figure 18. Retrait et installation d'un ventilateur de refroidissement 1. ensemble de ventilation 2. ventilateurs de refroidissement (7) 3. connecteurs des ventilateurs de refroidissement (7) Installation d'un ventilateur de refroidissement PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Ouvrez le système. 2. Alignez la prise située à la base du ventilateur de refroidissement sur le connecteur de la carte système. 3. Faites glisser le ventilateur dans les fentes jusqu'à ce qu'il s'enclenche. 4. Refermez le système. 56Clé de mémoire USB interne (en option) Une clé de mémoire USB optionnelle installée à l'intérieur de votre système peut être utilisée comme périphérique d'amorçage, clé de sécurité ou périphérique de stockage de masse. Le connecteur USB doit être activé par l'option de port USB interne de l'écran Périphériques intégrés du programme de configuration du système. Pour pouvoir démarrer le système à partir de la clé de mémoire USB, configurez cette dernière avec une image d'amorçage, puis ajoutez la clé à la séquence d'amorçage définie dans le programme de configuration du système. REMARQUE: Pour localiser le connecteur USB interne (J_USB_INT) de la carte système, reportez-vous à la section Connecteurs de la carte système. Remplacement de la clé USB interne PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Localisez le connecteur USB/la clé USB sur la carte système du serveur lame. Pour localiser le connecteur USB (J_USB_INT), reportez-vous à la section Connecteurs de la carte système. 4. Le cas échéant, retirez la clé USB. 5. Insérez la clé de mémoire USB dans le connecteur USB. 6. Refermez le système. 7. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 8. Accédez à la configuration du système et vérifiez que la clé USB a été détectée par le système. Figure 19. Remplacement de la clé USB interne 1. connecteur de clé de mémoire USB 2. clé de mémoire USB 57Cartes d'extension et cartes de montage pour cartes d'extension REMARQUE: Une carte de montage pour cartes d'extension manquante ou non prise en charge créé un événement dans le journal des événements système. Cela n'empêche pas votre système d'être mis sous tension et aucun message de l'auto-test de démarrage du BIOS ni de pause F1/F2 n'est affiché. Consignes d'installation des cartes d'extension Votre système prend en charge les cartes d'extension PCI Express Génération 3. REMARQUE: Une carte de montage manquante ou non prise en charge est consignée dans un événement SEL. Votre système se met néanmoins sous tension et aucun message POST BIOS ou de pause F1/F2 n'est affiché. Tableau 3. Cartes d'extension prises en charge Carte de montage Logement PCIe Connexion des processeurs Hauteur Longueur Largeur du lien Largeur du logement 2 1 Processeur 1 Demi-hauteur Mi-longueur x8 x16 Processeur 2 Demi-hauteur Mi-longueur x16 x16 3 2 Processeur 1 Pleine hauteur Longueur trois-quarts x16 x16 PRÉCAUTION: Si la carte fille réseau 10 GbE est installée, vous ne pouvez pas installer la carte GPU. REMARQUE: Seule une carte GPU de trois quart de longueur est prise en charge dans le logement de carte d'extension PCIe (logement 2) sur la carte de montage 3. REMARQUE: Vous pouvez installer des cartes d'extension uniquement sur le logement de carte de montage 2. REMARQUE: Les deux processeurs doivent être installés pour pouvoir utiliser le lien x16 du logement de carte de montage 2. Le tableau suivant fournit un guide d'installation des cartes d'extension pour un refroidissement approprié et un ajustement mécanique correct. Les cartes d'extension à la priorité la plus haute doivent être installées tout d'abord par priorité de logement indiquée. Toutes les autres cartes d'extension doivent être installées par ordre de priorité de carte et de priorité de logement. Tableau 4. Priorité d'installation des cartes d'extension Priorité de la carte Type de carte Priorité du logement Maximum autorisé 1 Pont PCIe 2 1 2 GPU 2 1 3 RAID 1 1 4 Adaptateur réseau convergé 1, 2 2 5 Cartes réseau 10 Gb 1, 2 2 6 HBA FC8 1, 2 2 7 Cartes réseau 1 Gb 1, 2 2 8 Non RAID 1, 2 2 58Priorité de la carte Type de carte Priorité du logement Maximum autorisé 9 HIC 1 1 Retrait d'une carte d'extension PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Déconnectez tous les câbles connectés à la carte d'extension ou à la carte de montage de carte d'extension. 4. Pour retirer la carte d'extension, ouvrez le loquet de cette dernière. 5. Tenez la carte d'extension par ses bords et retirez-la doucement de son connecteur sur la carte de montage. 6. Si vous retirez définitivement la carte, installez une plaque de recouvrement métallique sur l'emplacement non utilisé, puis refermez le loquet. REMARQUE: Vous devez installer une plaque de recouvrement sur un logement d'expansion vide pour conserver la certification FCC (Federal Communications Commission) du système. Les plaques empêchent également la pénétration de poussières et d'impuretés dans le système et favorisent le refroidissement et la circulation d'air dans le système. 7. Refermez le système. 8. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Figure 20. Retrait et installation de la carte d'extension 1. carte d'extension 2. connecteur de carte d'extension 593. loquet de carte d'extension Installation d'une carte d'extension PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Déballez la carte d'extension, puis préparez-la en vue de son installation. Pour obtenir des instructions, consultez la documentation fournie avec la carte. 2. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 3. Ouvrez le système. 4. Repérez le connecteur de la carte d'extension sur la carte de montage/système. 5. Ouvrez le loquet de la carte d'extension, puis retirez la plaque de recouvrement. 6. En tenant la carte par les bords, positionnez-la en alignant son connecteur latéral avec le connecteur de la carte d'extension. 7. Insérez fermement le connecteur du bord de la carte dans le connecteur de carte d'extension, jusqu'à ce que la carte soit en place. 8. Remettez en place le loquet de la carte d'extension. 9. Connectez les câbles à la carte d'extension, le cas échéant. REMARQUE: Lorsque vous installez une carte GPU sur la carte de montage 3, connectez le câble d'alimentation de la carte GPU au connecteur d'alimentation de la carte de montage 3. 10. Refermez le système. 11. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 12. Installez tous les pilotes de périphérique requis pour la carte, comme indiqué dans sa documentation. Retrait de cartes de montage de carte d'extension PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: La carte de montage de carte d'extension 1 et le lien x16 du logement de la carte de montage 2 peuvent être utilisés uniquement lorsque les deux processeurs sont installés. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. En maintenant les points de contact, soulevez la carte de montage de carte d'extension hors du connecteur de carte de montage de la carte système. 60Figure 21. Retrait et installation de la carte de montage de carte d'extension 1 1. carte de montage 1 2. carte d'extension 3. arrière du guide de carte de montage (droit) 4. arrière du guide de carte de montage (gauche) 5. connecteur Figure 22. Retrait et installation de la carte de montage de carte d'extension 3 611. connecteur 2. carte de montage de carte d'extension 3 4. Le cas échéant, retirez ou installez une carte d'extension sur la carte de montage. 5. Réinstallez la carte de montage de carte d'extension. 6. Refermez le système. 7. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Installation des cartes de montage pour cartes d'extension PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Le cas échéant, réinstallez les cartes d'extension dans la carte de montage pour cartes d'extension. 2. Alignez la carte de montage pour cartes d'extension sur le connecteur et la broche du guide de la carte de montage sur la carte système. 3. Abaissez la carte de montage pour cartes d'extension jusqu'à ce que son connecteur soit complètement enclenché. 4. Refermez le système. 5. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 6. Installez tous les pilotes de périphérique requis pour la carte, comme indiqué dans sa documentation. Carte SD vFlash La carte SD vFlash est une carte numérique sécurisée (SD/Secure Digital) qui se connecte dans un logement de carte SD vFlash sur le système. Elle offre des capacités de stockage local permanent à la demande et un environnement de déploiement personnalisé qui permet l'automatisation de la configuration des serveurs, des scripts et de l'imagerie. Elle émule les périphériques USB. Pour plus d'informations, consultez le Guide d'utilisation iDRAC7 à l'adresse support.dell.com/manuals. Remplacement de la carte SD vFlash REMARQUE: Cette procédure s'applique seulement au système 8 disques durs. 1. Localisez le logement du support vFlash sur le système. 2. Pour retirer la carte mémoire SD vFlash qui y est installée, poussez la carte vers l'intérieur pour la libérer. 3. Retirez la carte du logement. 62Figure 23. Retrait et installation de la carte SD vFlash 1. carte SD vFlash 2. logement pour carte SD vFlash 4. Pour installer la carte SD vFlash, placez le côté étiqueté de la carte vers le haut, puis insérez le bout de la broche de contact de la carte SD dans le logement de carte du module. REMARQUE: Le logement est muni d'un détrompeur qui permet d'insérer la carte dans le bon sens. 5. Appuyez sur la carte pour qu'elle s'enclenche dans son logement. Module SD interne double REMARQUE: Lorsque l'option Redundancy (Redondance) est définie sur Mirror Mode (Mode miroir) dans l'écran Integrated Devices (Périphériques intégrés), l'information est répliquée d'une carte SD à l'autre. Retrait du module SD interne double PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Localisez le double module SD qui est installlé sur le connecteur J_RIPS de la carte système. 4. Le cas échéant, retirez la ou les cartes SD. 5. Tout en maintenant la languette, tirez sur le double module SD pour le retirer de la carte système. 6. Refermez le système. 7. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 63Figure 24. Retrait et installation du module SD interne double 1. languette de retrait bleue 2. carte SD 1 3. carte SD 2 4. module SD double 5. connecteur de la carte système Installation du module SD interne double PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Repérez le connecteur J_RIPS de la carte système. 4. Alignez les connecteurs sur la carte système et le double module SD. 5. Tout en maintenant la languette, appuyez sur le double module SD jusqu'à ce qu'il soit bien positionné sur la carte système. 646. Refermez le système. 7. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Carte SD interne Retrait d'une carte SD interne PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Repérez le logement de la carte SD sur le module SD interne double ou la carte d'extension du fond de panier, puis exercez une pression sur la carte afin de la libérer et la retirer de son logement. 4. Refermez le système. 5. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Installation d'une carte SD interne PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Pour utiliser une carte SD avec le système, assurez-vous que le port correspondant est activé dans le programme de configuration du système. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Localisez le connecteur de la carte SD sur le module SD interne double ou sur la carte d'extension de fond de panier. En tournant le côté étiquetté vers le haut, insérez l'extrémité de la broche de contact dans le logement. REMARQUE: Le logement est muni d'un détrompeur qui permet d'insérer la carte dans le bon sens. 4. Exercez une pression sur la carte jusqu'à ce qu'elle se mette en place. 5. Refermez le système. 6. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 65Carte contrôleur de stockage intégrée Votre système comprend un logement de carte d'extension dédié sur la carte système pour une carte contrôleur intégrée qui fournit le sous-système de stockage intégré pour les disques durs internes de votre système. Le contrôleur prend en charge les disques durs SAS et SATA et vous permet également d'installer des disques durs en configuration RAID comme pris en charge par la version du contrôleur de stockage incluse dans votre système. Retrait de la carte contrôleur de stockage intégrée PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 2. Ouvrez le système. 3. Appuyez sur les deux languettes qui se trouvent sur le bord de la carte et extrayez la carte des extracteurs. Lorsque la carte est dégagée des picots de fixation, le connecteur situé sous la carte se désengage du connecteur de la carte système. 4. Orientez la carte de façon à ce que l'autre bout de la carte se désengage de la carte contrôleur de stockage sur la carte système. 5. Refermez le système. 661. connecteur de stockage sur la carte système 2. carte contrôleur de stockage 3. support de carte contrôleur de stockage 4. extracteurs (2) Installation de la carte contrôleur de stockage intégrée PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 2. Ouvrez le système. 3. Alignez une des extrémités de la carte sur le support de carte de la carte système. 4. Abaissez l'autre extrémité de la carte et alignez les trous qui se trouvent sur la carte avec les points de localisation des extracteurs de la carte système. 5. Appuyez sur les coins de la carte jusqu'à ce qu'elle soit complètement en place. Lorsque l'avant de la carte est en place, le picot de fixation en plastique s'emboîte sur le rebord du support. 6. Refermez le système. 7. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 67Carte fille réseau PRÉCAUTION: Si la carte GPU est installée, il est impossible d'installer la carte fille réseau de 10 GbE. Retrait de la carte fille réseau PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 2. Ouvrez le système. 3. Retirez le module de carte de montage pour carte d'extension : 4. À l'aide d'un tournevis cruciforme No. 2, désserrez les deux vis imperdables qui fixent la carte fille réseau sur la carte système. 5. Prenez la carte fille résau par les bords à côté des contacts et soulevez-la pour la retirer du connecteur de la carte système. 6. Faites glisser la carte fille réseau vers l'arrière en dehors du système jusqu'à ce que les connecteurs RJ-45 soient dégagés du logement du panneau arrière. 7. Enlevez la carte fille réseau du système. Figure 25. Retrait et installation de la carte fille réseau 1. supports de vis imperdables (2) 2. connecteur de la carte système 3. vis imperdables (2) 4. contact 5. carte fille réseau 686. logements du panneau arrière des connecteurs RJ-45 Installation de la carte fille réseau PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Si vous installez la carte fille réseau de 10 Gb, assurez-vous d'installer le carénage de refroidissement de la carte fille réseau dans votre système. 1. Orientez la carte de façon à ce que les connecteurs RJ-45 puissent passer dans le logement du panneau arrière. 2. Alignez les vis imperdables à l'arrière de la carte sur les trous qui se trouvent sur la carte système. 3. Appuyez sur le contact sur la carte pour vous assurer que le connecteur de la carte est en contact avec le connecteur de la carte système. 4. À l'aide d'un tournevis cruciforme No. 2, serrez les deux vis imperdables pour fixer la carte fille réseau à la carte système. 5. Installez la carte de montage 3 pour carte d'extension. 6. Refermez le système. 7. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Processeurs Utilisez la procédure suivante lors de : • l'installation d'un processeur supplémentaire • le remplacement d'un processeur REMARQUE: Pour assurer un refroidissement du système correct, vous devez installer un cache de processeur et un cache de dissipateur de chaleur dans un support de processeur vide. Retrait d'un processeur PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Avant de mettre à niveau votre système, téléchargez la dernière version du BIOS du système à partir du site support.dell.com. Suivez ensuite les instructions contenues dans le fichier de téléchargement compressé pour installer la mise à jour. REMARQUE: Vous pouvez mettre à jour le BIOS du système à l'aide de Lifecycle Controller. 2. Mettez le système hors tension, y compris tous les périphériques reliés, puis débranchez le système de sa prise électrique. Une fois le système débranché de sa source d'alimentation, appuyez sur le bouton d'alimentation et 69maintenez-le enfoncé pendant trois secondes pour vider le système de toute l'énergie accumulée avant de retirer le capot. 3. Ouvrez le système. 4. Retirez le carénage de refroidissement. AVERTISSEMENT: Le radiateur et le processeur restent chauds au toucher pendant quelques temps après l'arrêt du système. Laissez refroidir le radiateur et le processeur avant de les manipuler. PRÉCAUTION: Ne retirez jamais le dissipateur de chaleur d'un processeur, sauf si vous souhaitez retirer également le processeur. Le dissipateur de chaleur est essentiel au maintien de bonnes conditions thermiques. 5. À l'aide d'un tournevis cruciforme No. 2, desserrez un des supports de retenue du dissipateur de chaleur. Attendez 30 secondes que le dissipateur de chaleur se desserre du processeur. 6. Desserrez l'autre vis de fixation du dissipateur de chaleur. 7. Soulevez le dissipateur de chaleur pour le dégager du processeur, puis mettez-le de côté. Figure 26. Retrait et installation du dissipateur de chaleur 1. dissipateur de chaleur 2. supports de retenue (2) 3. vis de fixation (2) 4. processeur PRÉCAUTION: La pression exercée pour maintenir le processeur dans son support est très forte. Si vous ne maintenez pas fermement le levier d'éjection, il risque de se redresser brusquement. 8. Positionnez fermement votre pouce sur le levier d'éjection du support du processeur près de l'icône de déverrouillage et déverrouillez le levier en le poussant vers le bas et en le dégageant de sous la languette. 709. Positionnez fermement votre pouce sur le levier d'éjection du support du processeur près de l'icône de verrouillage et déverrouillez le levier en le poussant vers le bas et en le dégageant de sous la languette. Faites pivoter le levier de 90 degrés vers le haut. Figure 27. Séquence d'ouverture et de fermeture du levier du cadre de protection du processeur 1. symbole de verrouillage 2. levier d'éjection du support du processeur 3. processeur 4. levier d'éjection du support du processeur 5. symbole de déverrouillage 10. Faites pivoter le carénage du processeur vers le haut pour le dégager. PRÉCAUTION: Les broches du support sont fragiles et peuvent être endommagées. Faites attention à ne pas plier les broches lorsque vous retirez le processeur de son support. 11. Extrayez le processeur de son support et laissez le levier d'éjection ouvert en vue de l'installation du nouveau processeur. REMARQUE: Si vous retirez définitivement le processeur, vous devez installer un cache de processeur et un cache de dissipateur de chaleur dans son support afin d'assurer un refroidissement correct du système. REMARQUE: L'installation d'un cache de processeur/cache de dissipateur de chaleur est identique à l'installation d'un processeur/dissipateur de chaleur. 71Figure 28. Retrait et installation d'un processeur 1. levier d'éjection du support du processeur 2. indicateur de broche 1 3. levier d'éjection du support du processeur 4. cadre de protection du processeur 5. processeur 6. support ZIF 7. détrompeurs de support (4) 8. encoches du processeur (4) REMARQUE: Après avoir retiré le processeur, placez-le dans un conteneur antistatique pour le réutiliser, le renvoyer ou pour le stocker temporairement. Ne touchez pas le dessous du processeur. Touchez uniquement ses extrémités latérales. Si vous retirez le processeur du support de processeur 2, vous devez installer un cache de dissipateur de chaleur dans le support vide. Installation d'un processeur PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Si vous n'installez qu'un seul processeur, il doit être placé dans le support CPU1. 1. Avant de mettre à niveau votre système, téléchargez la dernière version du BIOS du système à partir du site support.dell.com. Suivez ensuite les instructions contenues dans le fichier de téléchargement compressé pour installer la mise à jour. 72REMARQUE: Vous pouvez mettre à jour le BIOS du système à l'aide de Lifecycle Controller. 2. Mettez le système hors tension, y compris tous les périphériques reliés, puis déconnectez le système de sa prise électrique. Une fois le système débranché de sa source d'alimentation, appuyez sur le bouton d'alimentation et maintenez-le enfoncé pendant trois secondes pour vider le système de toute l'énergie accumulée avant de retirer le capot. 3. Ouvrez le système. 4. Retirez le carénage de refroidissement. AVERTISSEMENT: Le radiateur et le processeur restent chauds au toucher pendant quelques temps après l'arrêt du système. Laissez refroidir le radiateur et le processeur avant de les manipuler. PRÉCAUTION: Ne retirez jamais le dissipateur de chaleur d'un processeur, sauf si vous souhaitez retirer également le processeur. Le dissipateur de chaleur est essentiel au maintien de bonnes conditions thermiques. 5. Retirez le dissipateur de chaleur/cache de dissipateur de chaleur et le processeur/cache de processeur, le cas échéant. REMARQUE: La procédure de retrait du cache de dissipateur de chaleur et du cache de processeur est similaire à celle du dissipateur de chaleur et du processeur. 6. Déballez le nouveau processeur. 7. Alignez le processeur sur les détrompeurs du support ZIF. PRÉCAUTION: Si le processeur n'est pas positionné correctement, il risque d'être endommagé ou d'endommager la carte système de manière permanente. Faites attention à ne pas plier les broches du support. PRÉCAUTION: Ne forcez pas l'installation du processeur. Lorsqu'il est positionné correctement, celui-ci s'enclenche facilement dans le support. 8. Mettez les leviers de dégagement du support de processeur en position ouverte, puis alignez la broche 1 du processeur, à l'aide du guide de positionnement de la broche 1 du support, comme référence, puis installez avec précaution le processeur dans son support. 9. Fermez le cadre de protection du processeur. 10. Faites pivoter le levier de dégagement du support en regard de l'icône de verrouillage jusqu'à ce qu'il soit en position verrouillée. 11. Faites pivoter à l'identique le levier de dégagement du support en regard de l'icône de déverrouillage jusqu'à ce qu'il soit en position verrouillée. 12. À l'aide d'un chiffon propre et non pelucheux, essuyez la pâte thermique du dissipateur de chaleur. PRÉCAUTION: Si vous appliquez trop de pâte thermique, celle-ci risque d'atteindre et de contaminer le support de processeur. 13. Ouvrez le paquet de pâte thermique fourni avec le kit du processeur, puis appliquez-en tout le contenu sur le centre de la face supérieure du nouveau processeur. 14. Placez le dissipateur de chaleur sur le processeur. 15. À l'aide d'un tournevis cruciforme n° 2, serrez les supports de retenue du dissipateur de chaleur. 16. Installez le carénage de refroidissement. 17. Refermez le système. 18. Rebranchez le système et les périphériques aux prises secteur, puis mettez le système sous tension. 19. Appuyez sur pour accéder à la configuration du système et vérifier que les informations relatives au processeur correspondent bien à la nouvelle configuration. 20. Lancez les diagnostics du système pour vérifier que le nouveau processeur fonctionne correctement. 73Blocs d'alimentation Votre système prend en charge : • Deux modules de bloc d'alimentation en CA de 495 W, 750 W ou 1100 W ou • Deux modules de bloc d'alimentation en CC 1100 W (le cas échéant). Lorsque deux blocs d'alimentation identiques sont installés, leur configuration est redondante (1 + 1). En mode redondant, le système est alimenté de manière égale par les deux blocs pour une efficacité optimale. Lorsqu'un seul bloc d'alimentation est installé, sa configuration est non redondante (1 + 0). Le système est alimenté par ce seul bloc d'alimentation. REMARQUE: Si deux blocs d'alimentation sont utilisés, ils doivent être de même type et avoir la même puissance de sortie d'alimentation maximale. PRÉCAUTION: Lorsque vous installez un bloc d'alimentation CA ou CC de 1100 W, vous devez les installer tous deux. Votre système ne prend pas en charge un seul bloc d'alimentation CA ou CC de 1100 W. Alimentation de rechange Votre système prend en charge la fonction d'alimentation de rechange, qui permet de réduire considérablement la surcharge d'alimentation associée à la redondance de blocs d'alimentation. Lorsque cette fonction est activée, un bloc d'alimentation redondant passe en état de veille. Le bloc d'alimentation actif prend en charge 100 % de la charge et fonctionne donc de façon plus efficace. Le bloc d'alimentation redondant en état de veille surveille la tension de sortie du bloc d'alimentation actif. Si celle-ci chute, il revient à l'état actif. Le bloc d'alimentation actif peut également activer un bloc d'alimentation en veille, lorsqu'il devient plus efficace d'avoir les deux blocs activés. Les valeurs par défaut des blocs d'alimentation activent les deux blocs si la charge sur le bloc d'alimentation actif est supérieure à 50 %, et mettent en veille le bloc redondant si la charge descend en dessous de 20 %. Vous pouvez configurer la fonction d'alimentation de rechange via les paramètres iDRAC. Pour plus d'informations sur les paramètres iDRAC, consultez le Guide d'utilisation iDRAC7 à l'adresse support.dell.com/manuals. Retrait d'un bloc d'alimentation en CA PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Le système exige un bloc d'alimentation pour fonctionner normalement. Sur les systèmes redondants, retirez et remplacez un seul bloc d'alimentation à la fois lorsque le système est sous tension. REMARQUE: Vous devrez peut-être détacher et soulever le bras de retenue optionnel du câble s'il empêche le retrait du bloc d'alimentation. Pour de plus amples informations sur le bras de retenue du câble, reportez-vous à la documentation de rack du système. 1. Débranchez le câble branché sur la source d'alimentation et sur le bloc à retirer, puis retirez les câbles de la bande Velcro. 2. Appuyez sur le loquet de dégagement, puis retirez le bloc d'alimentation du châssis. 74Figure 29. Retrait et installation d'un bloc d'alimentation en CA 1. connecteur 2. bloc d'alimentation 3. loquet de dégagement 4. poignée du bloc d'alimentation Installation d'un bloc d'alimentation en CA PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Vérifiez que les blocs d'alimentation sont de même type et qu'ils ont la même puissance maximale de sortie. REMARQUE: La puissance maximale (en watts) est indiquée sur l'étiquette du bloc d'alimentation. 2. Le cas échéant, retirez le cache du bloc d'alimentation. 3. Faites glisser le bloc d'alimentation dans le châssis jusqu'à ce qu'il s'emboîte complètement et que le loquet de dégagement s'enclenche. REMARQUE: Si vous avez débloqué le bras de gestion des câbles, ré-enclenchez-le. Pour plus d'informations sur le bras de gestion des câbles, reportez-vous à la documentation du système relative au rack. 4. Branchez le câble d'alimentation sur le bloc d'alimentation et branchez son autre extrémité sur une prise électrique. PRÉCAUTION: Lorsque vous branchez le câble d'alimentation, fixez-le à l'aide de la bande. REMARQUE: Lors de l'installation, du remplacement à chaud ou de l'ajout à chaud d'un bloc d'alimentation, attendez quelques secondes pour que le système reconnaisse le bloc d'alimentation et détermine son état. Le voyant d'état du bloc d'alimentation devient vert si le bloc d'alimentation fonctionne normalement. 75Instructions de câblage pour un bloc d'alimentation en CC Votre système prend en charge jusqu'à deux blocs d'alimentation –(48–60) V CC (selon disponibilité). AVERTISSEMENT: Pour les équipements qui utilisent des blocs d'alimentation en CC de 48 à 60 V, un électricien qualifié doit effectuer toutes les connexions à l'alimentation en CC et aux mises à la terre de sécurité. N'essayez pas d'établir la connexion à une source d'alimentation en CC ou d'installer les mises à la terre par vous-même. Tout le câblage électrique doit être conforme aux pratiques et aux codes locaux et nationaux en vigueur. Tout dommage provoqué par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Équipez l'unité uniquement de câbles en cuivre, de grosseur 10 AWG, supportant au moins 90 ºC pour la source et le retour. Protégez le bloc –(48–60) V CC (1 câble) avec un dispositif de protection contre les surtensions par circuit de dérivation 50 A pour CC avec un haut qualibre de relais d'interruption. PRÉCAUTION: Branchez l'équipement à une source d'alimentation –(48–60) V CC électriquement isolée de la source CA (source SELV –(48–60) V CC mise à la terre). Vérifiez que la source –(48–60) V CC est correctement reliée à la terre. REMARQUE: Un dispositif de désaccouplage accessible facilement, approuvé et qualifié, doit être intégré au câblage. Configuration d'entrée requise • Tension d'alimentation : –(48–60) V CC • Consommation électrique :: 32 A (maximum) Contenu du kit • Bloc de terminal Dell numéro de pièce 6RYJ9 ou équivalent (1) • Écrou n° 6-32 équipé d'une rondelle de blocage (1) Outils requis Pince à dénuder pouvant supprimer une isolation de calibre10 AWG solide ou toronnée, fil de cuivre isolé REMARQUE: Utiliser du fil alpha, numéro de pièce 3080 ou équivalent (torsade 65/30). Câbles requis • Un câble noir UL 10 AWG, 2 mètres maximum (torsadé) [–(48–60) V CC] • Un câble rouge UL 10 AWG, 2 mètres maximum (torsadé) (V CC au retour) • Un câble torsadé vert/jaune, vert avec bande jaune UL 10 AWG, 2 mètres maximum (mise à la terre) Assemblage et connexion du câble de terre de sécurité AVERTISSEMENT: Pour les équipements qui utilisent des blocs d'alimentation en CC de 48 à 60 V, un électricien qualifié doit effectuer toutes les connexions à l'alimentation en CC et aux mises à la terre de sécurité. N'essayez pas d'établir la connexion à une source d'alimentation en CC ou d'installer les mises à la terre par vous-même. Tout le câblage électrique doit être conforme aux pratiques et aux codes locaux et nationaux en vigueur. Tout dommage provoqué par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 761. Enlevez la protection isolante de l'extrémité du câble vert/jaune pour exposer environ 4,5 mm (0,175 pouce) de fil de cuivre. 2. À l'aide d'une pince à sertir manuelle (Tyco Electronics, 58433-3 ou équivalent), pincez la cosse à languette en anneau (Jeeson Terminals Inc., R5-4SA ou équivalent) sur le câble vert/jaune (câble de terre de sécurité). 3. Connectez le câble de terre de sécurité au point de mise à la terre à l'arrière du système à l'aide d'un écrou de taille 6-32 équipé d'une rondelle-frein. Figure 30. Assemblage et connexion du câble de terre de sécurité 1. câble de terre de sécurité 2. point de mise à la terre 3. rondelle-frein 4. rondelle élastique 5. écrou 6-32 Assemblage des câbles d'alimentation d'entrée en CC AVERTISSEMENT: Pour les équipements qui utilisent des blocs d'alimentation en CC de 48 à 60 V, un électricien qualifié doit effectuer toutes les connexions à l'alimentation en CC et aux mises à la terre de sécurité. N'essayez pas d'établir la connexion à une source d'alimentation en CC ou d'installer les mises à la terre par vous-même. Tout le câblage électrique doit être conforme aux pratiques et aux codes locaux et nationaux en vigueur. Tout dommage provoqué par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Enlevez la protection isolante de l'extrémité des câbles d'alimentation en CC pour exposer environ 13 mm (0,5 pouce) de fil de cuivre. 77AVERTISSEMENT: L'inversion de la polarité lors de la connexion des câbles d'alimentation en CC peut endommager de manière irréversible le bloc d'alimentation du système. 2. Insérez les extrémités en cuivre dans les connecteurs homologues et serrez les vis imperdables situées en haut des connecteurs homologues à l'aide d'un tournevis cruciforme No. 2. AVERTISSEMENT: Pour protéger le bloc d'alimentation des chocs électriques, les vis imperdables doivent être recouvertes du capuchon en caoutchouc avant d'insérer le connecteur homologue dans le bloc d'alimentation. 3. Faites pivoter les capuchons en caoutchouc dans le sens des aiguilles d'une montre pour les fixer sur les vis imperdables. 4. Insérez le connecteur homologue dans le bloc d'alimentation. Figure 31. Assemblage des câbles d'alimentation d'entrée en CC 1. support d'alimentation en CC 2. capuchon en caoutchouc 3. vis imperdables (2) 4. connecteur d'alimentation CC 5. câble –48 V 6. câble RTN 7. câble de terre Retrait d'un bloc d'alimentation en CC AVERTISSEMENT: Pour les équipements qui utilisent des blocs d'alimentation en CC de 48 à 60 V, un électricien qualifié doit effectuer toutes les connexions à l'alimentation en CC et aux mises à la terre de sécurité. N'essayez pas d'établir la connexion à une source d'alimentation en CC ou d'installer les mises à la terre par vous-même. Tout le câblage électrique doit être conforme aux pratiques et aux codes locaux et nationaux en vigueur. Tout dommage provoqué par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Le système exige un bloc d'alimentation pour un fonctionnement normal. Sur les systèmes redondants, retirez et remplacez un seul bloc d'alimentation à la fois lorsque le système est sous tension. 78REMARQUE: Vous devrez peut-être détacher et soulever le bras de retenue optionnel du câble s'il empêche le retrait du bloc d'alimentation. Pour de plus amples informations sur le bras de retenue du câble, reportez-vous à la documentation de rack du système. 1. Déconnectez les câbles d'alimentation de leur source d'alimentation et le connecteur du bloc d'alimentation à retirer. 2. Débranchez le câble de terre de sécurité. 3. Appuyez sur le loquet de dégagement, puis retirez le bloc d'alimentation du châssis. Figure 32. Retrait et installation d'un bloc d'alimentation en CC 1. connecteur 2. alimentation électrique 3. voyant d'état du bloc d'alimentation 4. loquet 5. poignée du bloc d'alimentation Installation d'un bloc d'alimentation en CC AVERTISSEMENT: Pour les équipements qui utilisent des blocs d'alimentation en CC de 48 à 60 V, un électricien qualifié doit effectuer toutes les connexions à l'alimentation en CC et aux mises à la terre de sécurité. N'essayez pas d'établir la connexion à une source d'alimentation en CC ou d'installer les mises à la terre par vous-même. Tout le câblage électrique doit être conforme aux pratiques et aux codes locaux et nationaux en vigueur. Tout dommage provoqué par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Vérifiez que les blocs d'alimentation sont de même type et qu'ils ont la même puissance maximale de sortie. REMARQUE: La puissance maximale de sortie (en watts) est indiquée sur l'étiquette du bloc d'alimentation. 2. Le cas échéant, retirez le cache du bloc d'alimentation. 3. Faites glisser le nouveau bloc d'alimentation dans le châssis jusqu'à ce qu'il s'emboîte complètement et que le loquet de dégagement s'enclenche. 79REMARQUE: Si vous avez détaché le bras de retenue du câble, attachez-le de nouveau. Pour de plus amples informations sur le bras de retenue du câble, reportez-vous à la documentation de rack du système. 4. Connectez le câble de terre de sécurité. 5. Installez le connecteur d'alimentation en CC dans le bloc d'alimentation. PRÉCAUTION: Lorsque vous connectez les câbles d'alimentation, fixez-les à l'aide de la bande Velcro à la poignée du bloc d'alimentation. 6. Connectez les câbles à une source d'alimentation en CC. REMARQUE: Lors de l'installation, du remplacement à chaud ou de l'ajout à chaud d'un nouveau bloc d'alimentation, attendez quelques secondes pour que le système reconnaisse le bloc d'alimentation et détermine son état. Le voyant d'état du bloc d'alimentation s'allume en vert pour indiquer que le bloc d'alimentation fonctionne correctement. Retrait d'un cache de bloc d'alimentation PRÉCAUTION: Pour assurer un refroidissement du système correct, il est nécessaire d'installer le cache du bloc d'alimentation dans la deuxième baie de bloc d'alimentation dans le cas d'une configuration non redondante. Retirez le cache du bloc d'alimentation uniquement si vous installez un deuxième bloc d'alimentation. Si vous installez un bloc d'alimentation secondaire, tirez sur le cache placé sur la baie vers l'extérieur pour l'extraire. Figure 33. Retrait et installation d'un cache de bloc d'alimentation 1. cache de bloc d'alimentation Installation du cache de bloc d'alimentation REMARQUE: Le cache de bloc d'alimentation ne doit être installé que sur la seconde baie d'alimentation. Pour installer le cache de bloc d'alimentation, alignez-le sur la baie d'alimentation, puis insérez-le dans le châssis jusqu'à ce qu'il se mette en place en émettant un déclic. 80Pile du système Remplacement de la pile du système AVERTISSEMENT: Il existe un risque d'explosion d'une nouvelle batterie si elle n'est pas correctement installée. Remplacez la batterie par une batterie identique ou équivalente recommandée par le fabricant. Pour en savoir plus, consultez les informations de sécurité. PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 2. Ouvrez le système. 3. Appuyez sur les contacts et soulevez le couvercle de la pile du système hors du carénage de refroidissement de la carte fille réseau. Figure 34. Retrait du couvercle de la pile du système 1. couvercle de la pile du système 2. carénage de refroidissement de la carte fille réseau 3. contacts 4. Localisez le support de pile. PRÉCAUTION: Pour ne pas endommager le connecteur de la pile, vous devez le maintenir fermement en place lorsque vous installez ou retirez une pile. 5. Pour retirer la pile, appuyez fermement sur le pôle positif du connecteur et retirez la pile des pattes de fixation sur le pôle négatif du connecteur. 81Figure 35. Remplacement de la pile du système 1. pôle positif du connecteur de pile 2. pile du système 3. pôle négatif du connecteur de pile 6. Pour installer une nouvelle pile dans le système, maintenez la pile avec le côté «+» vers le haut puis faites-la glisser sous les pattes de fixation sur le pôle positif du connecteur. 7. Appuyez sur la pile pour l'enclencher dans le connecteur. 8. Alignez l'arrière du couvercle de la pile système sur l'encoche de carénage de refroidissement de la carte fille réseau et appuyez sur le couvercle de la pile système pour qu'elle rentre dans les encoches et s'enclenche. 9. Refermez le système. 10. Rebranchez le système sur la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 11. Accédez au programme de configuration du système et vérifiez que la pile fonctionne correctement. 12. Entrez l'heure et la date exactes dans les champs Time (Heure) et Date du programme de configuration du système. 13. Quittez le programme de configuration du système. Fond de panier des disques durs The system supports a 2.5 inch (x4) SAS/SATA backplane. Retrait du fond de panier des disques durs PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Retirez le cadre avant s'il est installé. 2. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 3. Ouvrez le système. PRÉCAUTION: Pour éviter d'endommager les disques durs et le fond de panier, retirez les disques durs du système avant d'enlever le fond de panier de disque dur. 82PRÉCAUTION: Avant de retirer chaque disque dur, notez son numéro d'emplacement et étiquetez-le temporairement afin de pouvoir ensuite le réinstaller au même endroit. 4. Retirez tous les disques durs. 5. Débranchez le(s) câble(s) de données SAS/SATA/SSD et le câble d'alimentation du fond de panier. 6. Le cas échéant, débranchez le câble d'alimentation/de données du lecteur optique. 7. Poussez les pattes de dégagement bleues dans la direction indiquée par les flèches et faites glisser le fond de panier vers le haut. 8. Tirez le fond de panier hors du système jusqu'à ce que les logements de fixation soient libérés des pattes sur l'assemblage avant du châssis. Figure 36. Retrait et installation du fond de panier de disque dur 2,5 pouces (x4) 1. Fond de panier des disques durs 2. câble de transmission du fond de panier 3. câble d'alimentation du fond de panier 4. Patte de dégagement 5. câble SAS A 83Figure 37. Schéma de câblage—Systèmes à 4 disques durs de 2,5 pouces 1. support de maintien de câble 2. la carte système 3. carte contrôleur de stockage intégrée 4. connecteur SAS sur la carte système 5. fond de panier SAS Installation du fond de panier des disques durs PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Alignez les logements du fond de panier des disques durs avec les languettes du châssis en maintenant les languettes bleues. 2. Faites glissez vers le bas le fond de panier des disques durs jusqu'à ce que les languettes de retenue s'enclenchent. 3. Branchez le câble SAS A au connecteur SAS A sur le fond de panier et le câble SAS B au connecteur SAS B. 4. Connectez le(s) câble(s) d'alimentation au fond de panier des disques durs. 5. Faites passer les câbles d'alimentation et de données le long de la paroi du châssis. 6. Installez les disques durs dans leur emplacement d'origine. 847. Refermez le système. 8. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 9. Le cas échéant, installez le cadre avant. Assemblage du panneau de commande Retrait de la carte du panneau de commande PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Retirez le cadre avant s'il est installé. 2. Éteignez le système et les périphériques connectés, puis débranchez le système de la prise secteur et des périphériques. 3. Ouvrez le système. PRÉCAUTION: Le connecteur du module d'affichage est un connecteur ZIF (force d'insertion nulle). Assurez-vous que l'onglet de verouillage sur le connecteur est relâché avant le retrait et l'insertion. L'onglet de verrouillage doit être engagé après l'insertion. 4. Déconnectez les câbles du panneau de commande et du module d'affichage de la carte du panneau de commande. 5. À l'aide d'un tournevis cruciforme No. 2, retirez les deux vis qui fixent la carte du panneau de commande au châssis. 6. Faites glisser la carte du panneau de commande vers l'arrière du système et extrayez-la. Figure 38. Retrait et installation de la carte du panneau de commande 1. Carte du panneau de commande 2. Vis (2) 853. Câble du panneau de commande 4. câble du module d'affichage Installation de la carte du panneau de commande PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Alignez les trous de vis de la carte du panneau de commande sur ceux du châssis. 2. À l'aide d'un tournevis cruciforme no. 2, revissez les deux vis qui fixent la carte du panneau de commande au châssis. PRÉCAUTION: Le connecteur du module d'affichage est un connecteur ZIF (force d'insertion nulle). Assurez-vous que l'onglet de verouillage sur le connecteur est relâché avant le retrait et l'insertion. L'onglet de verrouillage doit être engagé après l'insertion. 3. Connectez le panneau de commande et les câbles de module d'affichage sur la carte du panneau de commande. 4. Le cas échéant, faites passer les câbles d'alimentation et de données le long de la paroi du châssis. 5. Refermez le système. 6. Le cas échéant, installez le cadre avant. 7. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Retrait du panneau de commande PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Retirez le cadre avant s'il est installé. 2. Éteignez le système et les périphériques connectés, puis débranchez le système de la prise secteur et des périphériques. 3. Ouvrez le système. PRÉCAUTION: Le connecteur du module d'affichage est un connecteur ZIF (force d'insertion nulle). Assurez-vous que l'onglet de verouillage sur le connecteur est relâché avant le retrait et l'insertion. L'onglet de verrouillage doit être engagé après l'insertion. 4. Débranchez le câble du module d'affichage de la carte du panneau de commande. 5. À l'aide d'un tournevis cruciforme No. 1, retirez la vis (située au bas du châssis) qui fixe le module de contrôle au châssis. REMARQUE: Outre la vis, le panneau de commande est équipé de trois languettes de fixation au châssis (une à gauche et deux en haut). PRÉCAUTION: Si vous tirez trop fort vers le haut, vous risquez d'endommager le panneau de commande. 866. Maintenez le panneau de commande par ses bords supérieurs et tirez-le vers le haut jusqu'à ce que ses languettes le libèrent. 7. Maintenez le panneau de commande par son bord droit et faites-le pivoter vers la gauche jusqu'à ce qu'il se détache du châssis. 8. Tirez le panneau de commande hors du châssis. Figure 39. Retrait et installation du panneau de commande 1. Panneau de commande 2. encoches de la paroi avant du châssis 3. connecteur ZIF du module d'affichage 4. câble du module d'affichage 5. Vis Installation du panneau de commande PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Faites glisser le côté gauche du panneau de commande dans le châssis de façon à ce que la languette gauche du panneau de commande s'aligne avec le logement sur la paroi du châssis et que la languette gauche supérieure s'aligne avec le logement sur le haut du châssis. 2. Insérez le câble de module d'affichage dans le châssis en le faisant passer par l'ouverture. 3. Appuyez sur le côté droit du panneau de commande jusqu'à ce que la languette droite supérieure s'aligne sur le haut du châssis et que le panneau s'enclenche. 4. À l'aide d'un tournevis cruciforme no. 1, replacez la vis (située au bas du châssis) qui fixe le module de commande au châssis. 87PRÉCAUTION: Le connecteur du module d'affichage est un connecteur ZIF (force d'insertion nulle). Assurez-vous que l'onglet de verouillage sur le connecteur est relâché avant le retrait et l'insertion. L'onglet de verrouillage doit être engagé après l'insertion. 5. Branchez le câble du module d'affichage sur la carte du panneau de commande. 6. Refermez le système. 7. Le cas échéant, installez le cadre avant. 8. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Module VGA Retrait du module VGA PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Cette procédure s'applique seulement au système 8 disques durs. 1. Retirez le cadre avant s'il est installé. 2. Éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur et déconnectez-le des périphériques. 3. Ouvrez le système. PRÉCAUTION: Le connecteur du module d'affichage est un connecteur ZIF (force d'insertion nulle). Assurez-vous que l'onglet de verouillage sur le connecteur est relâché avant le retrait et l'insertion. L'onglet de verrouillage doit être engagé après l'insertion. 4. Débranchez le câble du module d'affichage de la carte du panneau de commande. 5. Retirez le panneau de commande. 6. Déconnectez le câble du module VGA du module VGA. 7. À l'aide d'un tournevis cruciforme No. 2, retirez la vis qui fixe le module VGA au châssis. 8. Faites glisser le module VGA en dehors du châssis. 88Figure 40. Retrait et installation du module VGA 1. panneau de commande 2. câble du module d'affichage 3. vis (haut) 4. câble du module VGA 5. vis (bas) 6. module VGA Installation du module VGA REMARQUE: Cette procédure s'applique seulement au système 8 disques durs. PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Poussez le module VGA en position dans le châssis et alignez le trou de vis fileté du module VGA sur le trou de vis du châssis. 2. À l'aide d'un tournevis cruciforme no. 2, replacez la vis (au bas du châssis) qui fixe le module VGA au châssis. 3. Réinstallez le panneau de commande. 4. Connectez le câble du module VGA au module VGA. PRÉCAUTION: Le connecteur du module d'affichage est un connecteur ZIF (force d'insertion nulle). Assurez-vous que l'onglet de verouillage sur le connecteur est relâché avant le retrait et l'insertion. L'onglet de verrouillage doit être engagé après l'insertion. 5. Branchez le câble du module d'affichage sur la carte du panneau de commande. 6. Refermez le système. 7. Le cas échéant, installez le cadre avant. 898. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. Carte système Retrait de la carte système PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. PRÉCAUTION: Si vous utilisez le module Trusted Program Module (TPM) à l'aide d'une clé de chiffrage, vous serez peut-être invité à créer une clé de récupération au cours de la configuration du programme ou de la configuration du système. Assurez-vous de créer cette clé de récupération et de la stocker en sécurité. Si vous remplacez cette carte système, vous devez fournir cette clé de récupération lors du redémarrage du système ou du programme avant de pouvoir accéder aux données cryptées de vos disques durs. 1. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 2. Retirez le cadre avant s'il est installé. 3. Ouvrez le système. 4. Retirez les composants suivants : a) carénage de refroidissement b) modules de mémoire c) ventilateurs de refroidissement d) bloc(s) d'alimentation e) toutes les cartes de montage des cartes d'extension AVERTISSEMENT: Le dissipateur de chaleur reste chaud un certain temps après la mise hors tension du système. Veillez à ne pas toucher le(s) dissipateur(s) de chaleur lors du retrait de la carte système. f) dissipateur(s) de chaleur/caches de dissipateur de chaleur et processeur(s)/caches de processeur g) toutes les cartes d'extension et la carte contrôleur de stockage intégrée h) carte fille réseau i) module SD interne double j) clé USB interne (le cas échéant) k) disques durs remplaçables à chaud l) fond de panier des disques durs PRÉCAUTION: Pour éviter d'endommager le câble et le connecteur mini SAS, suivez la procédure correcte de retrait du câble mini SAS de la carte système. 5. Déconnectez le câble mini SAS de la carte système. a) Appuyez sur le connecteur du câble mini SAS pour le faire glisser au fond du connecteur (J_SASX8) de la carte système. b) Appuyez sur la languette métallique du connecteur de câble mini SAS et maintenez-la enfoncée. c) Tirez le câble mini SAS en dehors du connecteur de la carte système. 90a. connecteur de câble mini SAS b. languette métallique c. connecteur de la carte système 6. Débranchez tous les câbles de la carte système. PRÉCAUTION: Veillez à ne pas endommager le bouton d'identification du système lors du retrait de la carte système du châssis. 7. Saisissez le support de carte système, soulevez la broche de dégagement bleue, faites glisser la carte système vers l'avant du système, puis soulevez-la pour la dégager du châssis. PRÉCAUTION: Ne vous servez pas d'une barrette de mémoire, d'un processeur ou de tout autre composant pour soulever l'assemblage de la carte système. Figure 41. Retrait et installation de la carte système 1. carte système 2. support de carte système 3. broche de dégagement 91Installation de la carte système PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Déballez le nouvel assemblage de la carte système. PRÉCAUTION: Ne vous servez pas d'une barrette de mémoire, d'un processeur ou de tout autre composant pour soulever l'assemblage de la carte système. PRÉCAUTION: Veillez à ne pas endommager le bouton d'identification du système lors de la remise en place de la carte système dans le châssis. 2. Maintenez les contacts et abaissez la carte système dans le châssis. 3. Poussez la carte système vers l'arrière du châssis jusqu'à ce qu'elle s'enclenche. 4. Remettez les éléments suivants en place : a) fond de panier des disques durs b) disques durs remplaçables à chaud c) clé USB interne (le cas échéant) d) module SD interne double e) carte fille réseau f) toutes les cartes d'extension ainsi que la carte contrôleur de stockage intégrée. g) dissipateur(s) de chaleur/caches de dissipateur de chaleur et processeur(s)/caches de processeur h) toutes les cartes de montage des cartes d'extension i) bloc(s) d'alimentation j) ventilateurs de refroidissement k) modules de mémoire l) carénage de refroidissement 5. Branchez les câbles à l'assemblage de la carte système, au fond de panier SAS, à la carte du panneau de commande et au lecteur optique (le cas échéant). 6. Faites passer les câbles d'alimentation et de données le long de la paroi du châssis. 7. Refermez le système. 8. Le cas échéant, installez le cadre avant. 9. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 10. Importez votre licence iDRAC Enterprise (nouvelle ou déjà existante). Pour plus d'informations, reportez-vous au iDRAC7 User's Guide (Guide d'utilisation iDRAC7) à l'adresse support.dell.com/manuals. 924 Dépannage du système La sécurité en priorité, pour vous et votre système PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. Dépannage des échecs de démarrage du système Si vous démarrez le système en mode de démarrage BIOS après l'installation du système d'exploitation à partir du Gestionnaire de démarrage UEFI, le système se bloquera. L'inverse est également vrai. Vous devez démarrer en utilisant le même mode de démarrage que celui avec lequel vous avez installé le système d'exploitation. Pour tous les autres problèmes de démarrage, notez les messages du système qui apparaissent à l'écran. Dépannage des connexions externes Avant de procéder au dépannage de tout périphérique externe, assurez-vous que tous les câbles externes sont correctement fixés aux connecteurs externes de votre système. Dépannage du sous-système vidéo 1. Vérifiez les branchements du moniteur (prise secteur et raccordement au système). 2. Vérifiez le câblage de l'interface vidéo entre le système et le moniteur. 3. Exécutez le test de diagnostic approprié. Si les tests aboutissent, le problème n'est pas lié au matériel vidéo. Si les tests échouent, reportez-vous à la section Obtention d'aide. Dépannage d'un périphérique USB Effectuez les étapes suivantes pour dépanner un clavier/une souris USB. Pour tous les autres périphériques USB, passez à l'étape 7. 1. Débranchez un court instant du système les câbles du clavier ou de la souris, puis reconnectez-les. 2. Connectez le clavier ou la souris aux ports USB situés sur le côté opposé du système. 3. Si l'incident est résolu, redémarrez le système, accédez au programme de configuration du système et vérifiez que les ports USB défectueux sont activés. 4. Remplacez le clavier ou la souris par un périphérique équivalent en état de marche. 5. Si le problème est résolu, remplacez le périphérique (clavier ou souris) défectueux. 936. Si le problème persiste, passez à l'étape suivante pour dépanner les autres périphériques USB reliés au système. 7. Mettez hors tension tous les périphériques USB et déconnectez-les du système. 8. Redémarrez le système et, si votre clavier fonctionne, entrez dans le programme de configuration du système. Vérifiez que tous les ports USB sont activés dans l'écran Integrated Devices (Périphériques intégrés), dans les options du programme de configuration du système. Si votre clavier ne fonctionne pas, vous pouvez également utiliser l'accès distant. Si le système n'est pas accessible, réinitialisez le cavalier NVRAM_CLR à l'intérieur de votre système et restaurez les paramètres par défaut du BIOS. 9. Reconnectez et remettez sous tension les périphériques USB un par un. 10. Si un périphérique provoque un problème similaire, mettez-le hors tension, remplacez le câble USB si nécessaire, puis remettez le périphérique sous tension. Si toutes les tentatives de dépannage échouent, reportez-vous à la section Obtention d'aide. Dépannage d'un périphérique d'E/S série 1. Mettez hors tension le système et les périphériques connectés au port série. 2. Remplacez le câble d'interface série par un câble fiable, puis mettez le système et le périphérique série sous tension. Si vous avez résolu le problème, remplacez le câble d'interface par un câble réputé fiable. 3. Mettez hors tension le système et le périphérique série, puis remplacez ce dernier par un périphérique similaire. 4. Mettez sous tension le système et le périphérique série. Si le problème persiste, reportez-vous à la section Obtention d'aide. Dépannage d'une carte réseau 1. Lancez les tests de diagnostic adéquats. Reportez-vous à la section Utilisation des diagnostics système pour connaître les tests de diagnostic disponibles. 2. Redémarrez le système et consultez les messages éventuels concernant le contrôleur de carte réseau. 3. Vérifiez le voyant approprié du connecteur de carte réseau : – Si le voyant de liaison ne s'allume pas, vérifiez tous les branchements. – Si le voyant d'activité ne s'allume pas, les fichiers des pilotes réseau sont peut-être endommagés ou manquants. Retirez et réinstallez les pilotes, le cas échéant. Reportez-vous à la documentation de votre carte réseau. – Le cas échéant, modifiez le paramètre d'autonégociation. – Utilisez un autre connecteur sur le commutateur ou le concentrateur. 4. Assurez-vous que les pilotes appropriés sont installés et que les protocoles sont liés. Reportez-vous à documentation de votre carte réseau. 5. Entrez dans le programme de configuration du système, et confirmez que les ports de la carte réseau sont activés dans l'écran Périphériques intégrés. 6. Assurez-vous que les cartes réseau, les concentrateurs et les commutateurs du réseau sont tous configurés sur la même vitesse de transmission de données et en recto-verso. Reportez-vous à la documentation de chaque périphérique réseau. 7. Vérifiez que tous les câbles réseau sont du type approprié et qu'ils ne dépassent pas la longueur maximale. Si toutes les tentatives de dépannage échouent, reportez-vous à la section Obtention d'aide. 94Dépannage d'un système mouillé PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 2. Ouvrez le système. 3. Désassemblez les composants du système : – Disques durs – Fond de panier des disques durs – clé de mémoire USB – Carénage de refroidissement – Cartes de montage de carte d'extension (le cas échéant) – Cartes d'extension – Bloc)s) d'alimentation – Module de ventilation, le cas échéant – Ventilateurs de refroidissement – Processeur(s) et dissipateur(s) de chaleur – Barrettes de mémoire 4. Laissez sécher le système pendant au moins 24 heures. 5. Réinstallez les composants retirés à l'étape 3. 6. Refermez le système. 7. Mettez sous tension le système et les périphériques qui y sont connectés. Si le système ne démarre pas normalement, reportez-vous à la section Obtention d'aide. 8. Si le système démarre normalement, arrêtez-le et réinstallez les cartes d'extension que vous avez retirées. 9. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Si les tests échouent, reportez-vous à la section Obtention d'aide. Dépannage d'un système endommagé PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 2. Ouvrez le système. 3. Assurez-vous que les composants suivants sont correctement installés : 95– Carénage de refroidissement – Cartes de montage de carte d'extension (le cas échéant) – Cartes d'extension – Bloc)s) d'alimentation – Module de ventilation, le cas échéant – Ventilateurs de refroidissement – Processeur(s) et dissipateur(s) de chaleur – Barrettes de mémoire – Supports de disque dur – Fond de panier des disques durs 4. Vérifiez que tous les câbles sont connectés correctement. 5. Refermez le système. 6. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Si les tests échouent, reportez-vous à la section Obtention d'aide. Dépannage de la pile du système PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Si le système est hors tension pendant une longue période (des semaines ou des mois), la NVRAM peut perdre ses informations de configuration du système. Cette situation est provoquée par une pile défectueuse. 1. Entrez de nouveau l'heure et la date dans le programme de configuration du système. 2. Mettez le système hors tension et débranchez-le de la prise secteur pendant au moins une heure. 3. Rebranchez le système à la prise secteur et mettez-le sous tension. 4. Accédez à la configuration du système. Si la date et l'heure sont incorrectes dans la configuration du système, vérifiez si le SEL affiche des messages de pile système. Si le problème n'est pas résolu, reportez-vous à la section Obtention d'aide. REMARQUE: Il se peut que certains logiciels fassent accélérer ou ralentir l'heure du système. Si le système semble fonctionner normalement hormis l'heure se trouvant dans la configuration du système, le problème provient peut- être du logiciel plutôt que d'une batterie défectueuse. Dépannage des blocs d'alimentation PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Réinstallez le bloc d'alimentation en procédant d'abord à son retrait, puis à sa réinstallation. 96REMARQUE: Après avoir installé un bloc d'alimentation, patientez quelques secondes pour laisser au système le temps de le reconnaître et de déterminer s'il fonctionne correctement. 2. Si le problème persiste, reportez-vous à la section Obtention d'aide. Dépannage des problèmes de refroidissement PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. Assurez-vous qu'aucune des conditions suivantes n'existe : • Retrait du capot du système, du carénage de refroidissement, de la plaque de recouvrement EMI, du cache de barrette de mémoire ou de plaque de recouvrement arrière. • La température ambiante est trop élevée. • La circulation de l'air extérieur est bloquée. • Retrait ou panne de l'un des ventilateurs de refroidissement. • Les consignes d'installation de la carte d'extension n'ont pas été respectées. Dépannage des ventilateurs de refroidissement PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Ouvrez le système. 2. Remettez en place le ventilateur ou le câble d'alimentation du ventilateur. 3. Si le ventilateur fonctionne correctement, fermez le système. Si le problème persiste, reportez-vous à la section Obtention d'aide. Dépannage de la mémoire système PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Si le système est opérationnel, lancez les tests de diagnostic adéquats. Reportez-vous à la section Utilisation des diagnostics système pour connaître les tests de diagnostic disponibles. Si les diagnostics indiquent une panne, suivez les instructions fournies par le programme de diagnostic. 2. Si le système n'est pas opérationnel, mettez-le hors tension ainsi que ses périphériques connectés, puis débranchez-le de sa source d'alimentation. Patientez au moins 10 secondes, puis reconnectez le système à sa source d'alimentation. 3. Mettez le système et les périphériques qui y sont connectés sous tension, puis notez les messages qui s'affichent à l'écran. 97Si un message d'erreur indiquant une panne de module de mémoire s'affiche, passez à l'étape 12. 4. Entrez dans le programme de configuration du système et vérifiez les paramètres de mémoire du système. Modifiez-les si nécessaire. Si un problème persiste, bien que les paramètres de la mémoire correspondent à la mémoire installée, passez à l'étape 12. 5. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 6. Ouvrez le système. 7. Vérifiez les canaux de mémoire et assurez-vous que l'installation des barrettes est correcte. 8. Remboîtez les barrettes de mémoire dans leurs supports. 9. Refermez le système. 10. Accédez à la configuration du système et vérifiez le paramètre de la mémoire système. Si le problème persiste, passez à l'étape suivante. 11. Ouvrez le système. 12. Si un test de diagnostic ou un message d'erreur indique une panne d'un module de mémoire spécifique, installez un module qui fonctionne à la place du module défectueux. 13. Pour dépanner une barrette de mémoire défectueuse non identifiée, remplacez la barrette du premier logement de barrette DIMM par une autre de même type et de même capacité. Si un message d'erreur s'affiche à l'écran, il peut s'agir d'un problème lié au type des DIMM installées, d'une installation incorrecte des DIMM ou de DIMM défectueuse(s). Suivez les instructions qui s'affichent à l'écran pour résoudre le problème. Pour de plus amples informations, reportez-vous aux consignes générales d'installation des modules de mémoire. 14. Refermez le système. 15. Pendant l'amorçage du système, observez les voyants de diagnostic du panneau avant et les messages d'erreur qui s'affichent. 16. Si le problème de mémoire est toujours indiqué, répétez les étapes 12 à 15 pour chaque module de mémoire installé. Si le problème persiste alors que vous avez vérifié toutes les barrettes de mémoire, reportez-vous à la section Obtention d'aide. Dépannage d'une clé USB interne PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Entrez dans le programme de configuration du système et assurez-vous que le Port de clé USB est activé depuis l'écran Integrated Devices (Périphériques intégrés). 2. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 3. Ouvrez le système. 4. Identifiez la clé USB et remettez-la en place. 5. Refermez le système. 6. Mettez le système et les périphériques qui y sont connectés sous tension, puis vérifiez que la clé USB fonctionne correctement. 987. Si le problème persiste, répétez les étapes 2 et 3. 8. Insérez une autre clé USB en état de marche. 9. Refermez le système. Si le problème n'est pas résolu, reportez-vous à la section Obtention d'aide. Dépannage d'une carte SD PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Certaines cartes SD sont équipées d'un commutateur physique de protection contre écriture. Si le commutateur de protection contre écriture est allumé, il est impossible d'écrire sur la carte SD. 1. Accédez à la configuration du système et vérifiez qu'Internal SD Card Port (Port de la carte SD interne) est activé. 2. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 3. Ouvrez le système. PRÉCAUTION: Si l'option Internal SD Card Redundancy (Redondance de la carte SD interne) est réglée sur le mode Mirror (Miroir) dans l'écran Integrated Devices (Périphériques intégrés) de la configuration du système, vous devez suivre les instructions décrites aux étapes 4 à 7 pour éviter toute perte de données. REMARQUE: Lorsqu'une panne de carte SD survient, le contrôleur de module SD interne double la signale au système. Lors du redémarrage suivant, le système affiche un message indiquant la panne. 4. Si l'option Internal SD Card Redundancy (Redondance de la carte SD interne) est réglée sur Disabled (Désactivé), remplacez la carte SD défectueuse par une nouvelle. 5. Si la carte SD 1 a échoué, retirez la carte du logement de carte SD 1. Si la carte SD 2 a échoué, installez une nouvelle carte SD dans le logement de carte SD 2, puis passez à l'étape 7. 6. Retirez la carte se trouvant dans le logement de carte SD 2 et insérez-la dans le logement de carte SD 1. 7. Insérez la nouvelle carte SD dans le logement de carte SD 2. 8. Refermez le système. 9. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 10. Accédez à la configuration du système et assurez-vous que les modes Internal SD Card Port (Port de carte SD interne) et Internal SD Card Redundancy (Redondance de la carte SD interne) sont activés. 11. Vérifiez que la carte SD fonctionne correctement. Si le problème persiste, reportez-vous à la section Obtention d'aide. Dépannage d'un lecteur optique PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 991. Utilisez un autre CD ou DVD. 2. Accédez au programme de configuration du système et vérifiez que le contrôleur SATA intégré et le port du lecteur SATA sont activés. 3. Exécutez le test de diagnostic approprié. 4. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 5. Ouvrez le système. 6. Retirez le cadre avant. 7. Vérifiez que le câble d'interface est correctement branché sur le lecteur optique et le contrôleur. 8. Vérifiez que le câble d'alimentation est bien connecté au lecteur. 9. Refermez le système. Si le problème n'est pas résolu, reportez-vous à la section Obtention d'aide. Dépannage d'une unité de sauvegarde sur bande PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Essayez d'utiliser une autre cartouche de bande. 2. Assurez-vous que les pilotes de périphérique de l'unité de sauvegarde sur bande sont correctement installés et configurés. Consultez la documentation du lecteur de bande pour plus d'informations à propos des pilotes de périphérique. 3. Réinstallez le logiciel de sauvegarde sur bande en suivant la procédure indiquée dans sa documentation. 4. Vérifiez que le câble d'interface du lecteur de bande est correctement branché au port externe de la carte contrôleur. 5. Assurez-vous que la carte contrôleur est correctement installée : a) Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. b) Ouvrez le système. c) Repositionnez la carte contrôleur dans le logement de carte d'extension. d) Refermez le système. e) Mettez sous tension le système et les périphériques qui y sont connectés. 6. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Si vous ne parvenez pas à résoudre le problème, reportez-vous à la section Obtention d'aide. Dépannage d'un disque dur PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 100PRÉCAUTION: Cette procédure de dépannage peut détruire les données stockées sur le disque dur. Avant de poursuivre, sauvegardez tous les fichiers présents sur le disque dur. 1. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Selon les résultats du test de diagnostic, effectuez les étapes appropriées de la procédure ci-dessous. 2. Si le système est doté d'un contrôleur RAID et si les disques durs sont configurés dans une matrice RAID, procédez comme suit : a) Redémarrez le système et appuyez sur la touche durant le redémarrage du système pour exécuter le Lifecycle Controller, exécutez ensuite l'assistant de configuration de matériel pour vérifier la configuration RAID. Reportez-vous à la documentation du Lifecycle Controller ou à l'aide en ligne pour des informations sur la configuration RAID. b) Assurez-vous que les disques durs ont été correctement configurés pour la matrice RAID. c) Mettez le disque dur hors ligne, puis réinsérez-le. d) Quittez l'utilitaire de configuration et laissez le système d'exploitation démarrer. 3. Assurez-vous que les pilotes de périphérique pour votre carte contrôleur sont correctement installés et configurés. Pour en savoir plus, reportez-vous à la documentation sur le système d'exploitation. 4. Redémarrez le système et accédez au programme de configuration du système. 5. Vérifiez que le contrôleur est activé et que les lecteurs apparaissent dans le programme de configuration du système. Si le problème persiste, essayez de dépanner les cartes d'expansion ou reportez-vous à la section Obtention d'aide. Dépannage d'un contrôleur de stockage PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Pour dépanner un contrôleur SAS ou PERC, reportez-vous à sa documentation et à celle du système d'exploitation. 1. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. 2. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 3. Ouvrez le système. 4. Vérifiez que les cartes d'extension installées sont conformes aux consignes d'installation correspondantes. 5. Vérifiez que chaque carte d'extension est correctement insérée dans son connecteur. 6. Refermez le système. 7. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 8. Si le problème n'est pas résolu, éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur. 9. Ouvrez le système. 10. Retirez toutes les cartes d'extension du système. 11. Refermez le système. 10112. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 13. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Si le test échoue, reportez-vous à la section Obtention d'aide. 14. Pour chaque carte d'extension retirée à l'étape 10, effectuez les opérations suivantes : a. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. b. Ouvrez le système. c. Réinstallez une des cartes d'extension. d. Refermez le système. e. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Si les tests échouent, reportez-vous à la section Obtention d'aide. Dépannage des cartes d'extension PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. REMARQUE: Pour dépanner une carte d'extension, consultez sa documentation et celle du système d'exploitation. 1. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. 2. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 3. Ouvrez le système. 4. Vérifiez que chaque carte d'extension est correctement insérée dans son connecteur. 5. Refermez le système. 6. Si le problème n'est pas résolu, éteignez le système et les périphériques qui y sont connectés, puis débranchez le système de la prise secteur. 7. Ouvrez le système. 8. Retirez toutes les cartes d'extension du système. 9. Refermez le système. 10. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Si les tests échouent, reportez-vous à la section « Obtention d'aide ». 11. Pour chaque carte d'extension retirée à l'étape 8, effectuez les opérations suivantes : a) Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. b) Ouvrez le système. c) Réinstallez une des cartes d'extension. d) Refermez le système. e) Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Si un problème est toujours signalé, reportez-vous à la section Obtention d'aide. 102Dépannage des processeurs PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Effectuez le test de diagnostic approprié. Reportez-vous à la section Utilisation des diagnostics système pour voir les tests de diagnostic disponibles. 2. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 3. Ouvrez le système. 4. Vérifiez que le processeur et le dissipateur de chaleur sont correctement installés. 5. Refermez le système. 6. Exécutez le test de diagnostic approprié. Pour plus d'informations, reportez-vous à la section Utilisation des diagnostics système. Si un problème est toujours signalé, reportez-vous à la section Obtention d'aide . 1031045 Utilisation des diagnostics du système Si vous rencontrez un problème avec le système, exécutez les diagnostics du système avant de contacter l'assistance technique de Dell. L'exécution des diagnostics du système permet de tester le matériel du système sans équipement supplémentaire ou risque de perte de données. Si vous ne pouvez pas résoudre vous-même le problème, le personnel de maintenance ou d'assistance peut utiliser les résultats des diagnostics pour vous aider à résoudre le problème. Dell Online Diagnostics Dell Online Diagnostics est une suite autonome de programmes de diagnostic ou de modules de tests qui vous permet d'exécuter des tests de diagnostic sur des systèmes Dell dans un environnement de production tout en optimisant le temps de disponibilité de vos systèmes. Online Diagnostics vous permet d'exécuter des tests de diagnostic sur les châssis et les composants de stockage tels que les disques durs, la mémoire physique et les cartes d'interface réseau. Vous pouvez utiliser l'interface utilisateur graphique (IUG) ou l'interface de ligne de commande (CLI) pour exécuter des tests de diagnostic sur le matériel découvert par Online Diagnostics sur votre système. Pour obtenir plus d'informations sur l'utilisation des diagnostics, reportez-vous au Dell Online PowerEdge Diagnostics User’s Guide (Guide d'utilisation de Dell PowerEdge Diagnostics) sous Software → Serviceability Tools (Outils de services logiciels) à l'adresse support.dell.com/manuals. Diagnostics du système intégré Dell REMARQUE: Également connu sous le nom de diagnostics ePSA (Enhanced Pre-boot System Assessment). Les diagnostics du système intégré offrent un ensemble d'options pour des périphériques ou des groupes de périphériques particuliers, vous permettant : • d'exécuter des tests automatiquement ou dans un mode interactif • de répéter des tests • d'afficher ou d'enregistrer les résultats des tests • d'exécutez des tests complets pour introduire des options de test supplémentaires afin d'offrir des informations supplémentaires sur le ou les périphériques déféctueux • d'afficher des messages d'état vous indiquant si les tests ont réussi • d'afficher les messages d'erreur indiquant les problèmes rencontrés au cours des tests Quand utiliser les diagnostics intégrés du système Si un composant ou un périphérique important dans le système ne fonctionne pas correctement, l'exécution des diagnostics intégrés du système peut indiquer un dysfonctionnement du composant. Exécution des diagnostics intégrés du système Le programme de diagnostics intégrés du système s'exécute à partir de l'écran Dell Lifecycle Controller. 105PRÉCAUTION: Utilisez les diagnostics intégrés du système pour tester uniquement votre système. L'utilisation de ce programme avec d'autres systèmes peut entraîner des résultats invalides ou des messages d'erreur. 1. Au démarrage du système, appuyez sur . 2. Utilisez les touches fléchées vers le haut et vers le bas pour sélectionner System Utilities (Utilitaires système) → Launch Dell Diagnostics (Lancer les diagnostics Dell). La fenêtre ePSA Pre-boot System Assessment (Évaluation du système au pré-amorçage ePSA) s'affiche, répertoriant tous les périphériques détectés dans le système. Le diagnostic démarre l'exécution des tests sur tous les périphériques détectés. Commandes du diagnostic du système Menu Description Configuration Affiche la configuration et les informations relatives à la condition de tous les périphériques détectés. Results (Résultats) Affiche les résultats de tous les tests exécutés. System Health (Intégrité du système) Propose un aperçu de la performance du système actuel. Event Log (Journal d'événements) Affiche un journal daté des résultats de tous les tests exécutés sur le système. Il est affiché si au moins une description d'un évènement est enregistrée. Pour obtenir plus d'informations sur les diagnostics intégrés du système, reportez-vous au Dell Enhanced Pre-boot System Assessment User Guide (Guide de l'utilisateur de l'évaluation améliorée du système de pré-amorçage Dell) à l'adresse support.dell.com/manuals. 1066 Cavaliers et connecteurs Paramètres des cavaliers de la carte système Pour obtenir des informations sur la réinitialisation du cavalier du mot de passe afin de désactiver un mot de passe, reportez-vous à la section Désactivation d'un mot de passe oublié. Tableau 5. Paramètres des cavaliers de la carte système Cavalier Réglage Description PWRD_EN (par défaut) La fonction mot de passe est activée (broches 4–6). La fonction de mot de passe est désactivée (broches 2 à 4). L'accès local à l'iDRAC sera déverrouillé lors du prochain cycle de mise sous tension CA. NVRAM_CLR (par défaut) Les paramètres de configuration sont conservés au démarrage du système (broches 1-3). Les paramètres de configuration sont effacés au prochain démarrage du système (broches 3-5). 107Connecteurs de la carte système Figure 42. Connecteurs et cavaliers de la carte système. Élément Connecteur Description 1 J_PS2 Connecteur d'alimentation PSU 2 2 J_SATA_CD Connecteur SATA du lecteur optique 3 J_BP0 Connecteur d'alimentation du fond de panier des disques durs 4 J_TBU Connecteur d'alimentation de l'unité de sauvegarde de bande. 5 J_PS1 Connecteur d'alimentation PSU 1 6 J_RIPS Connecteur d'unité redondante de stockage permanent interne 7 J_NDC Connecteur de la carte fille réseau 8 J_RISER_3A Connecteur de la carte de montage 3 108Élément Connecteur Description 9 J_RISER_3B Connecteur de la carte de montage 3 10 J_USB Connecteur USB 11 J_VIDEO_REAR Connecteur vidéo 12 J_COM1 Connecteur série 13 J_IDRAC_RJ45 Connecteur iDRAC7 14 J_CYC Connecteur d'identification du système 15 CYC_ID Bouton d'identification du système 16 J_RISER_2A Connecteur de la carte de montage 2 17 J_RISER_1A Connecteur de la carte de montage 1 18 TOUCH POINT Point de contact pour saisir la carte système 19 J_RISER_2B Connecteur de la carte de montage 2 20 J_RISER_1B Connecteur de la carte de montage 1 21 J_STORAGE Connecteur de la carte contrôleur de stockage 22 J_SASX8 Connecteur SATA 23 J_USB_INT Connecteur USB interne 24 BAT Connecteur de la pile 25 CPU2 Support du processeur 2 26 B1, B5, B9, B2, B6, B10 Supports de barrette de mémoire 27 J_FAN2U_7 Connecteur du ventilateur de refroidissement 28 J_FAN2U_6 Connecteur du ventilateur de refroidissement 29 J_FAN2U_5 Connecteur du ventilateur de refroidissement 30 J_FAN2U_4 Connecteur du ventilateur de refroidissement 31 A1, A5, A9, A2, A6, A10, B3, B7, B11, B4, B8, B12 Supports de barrette de mémoire 32 J_FAN1U_3 Connecteur du ventilateur de refroidissement 33 J_BP1 Connecteur d'alimentation du fond de panier 34 J_FAN1U_2 Connecteur du ventilateur de refroidissement 35 J_FAN1U_1 Connecteur du ventilateur de refroidissement 36 A12, A8, A4, A7, A11, A3 Supports de barrette de mémoire 37 J_CP Connecteur d'interface du panneau de commande 38 CPU1 Support du processeur 1 39 J_FP_USB Connecteur USB du panneau avant 40 J_BP_SIG1 Connecteur de transmission de fond de panier 1 41 J_BP_SIG0 Connecteur de transmission de fond de panier 0 109Désactivation d'un mot de passe oublié Les fonctionnalités logicielles de protection du système comprennent un mot de passe du système et un mot de passe de configuration. Le cavalier de mot de passe permet d'activer ou de désactiver ces mots de passe et d'effacer le(s) mot(s) de passe utilisé(s). PRÉCAUTION: La plupart des réparations ne peuvent être effectuées que par un technicien de maintenance agréé. N'effectuez que les opérations de dépannage et les petites réparations autorisées par la documentation de votre produit et suivez les instructions fournies en ligne ou par téléphone par l'équipe de maintenance et d'assistance technique. Tout dommage causé par une réparation non autorisée par Dell est exclu de votre garantie. Consultez et respectez les consignes de sécurité fournies avec votre produit. 1. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 2. Ouvrez le système. 3. Déplacez le cavalier qui se trouve sur la carte système des broches 4 et 6 aux broches 2 et 4. 4. Refermez le système. Les mots de passe existants ne sont pas désactivés (effacés) tant que le système n'a pas démarré avec le cavalier qui se trouve sur les broches 2 et 4. Par contre, avant d'assigner un nouveau mot de passe système et/ou configuration, vous devez redéplacer le cavalier aux broches 4 et 6. REMARQUE: Si vous attribuez un nouveau mot de passe système et/ou de configuration alors que le cavalier est toujours sur les broches 2 et 4, le système désactive les nouveaux mots de passe à son prochain démarrage. 5. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 6. Mettez le système et les périphériques qui y sont connectés hors tension, puis débranchez le système de la prise secteur. 7. Ouvrez le système. 8. Déplacez le cavalier qui se trouve sur la carte système des broches 2 et 4 aux broches 4 et 6. 9. Refermez le système. 10. Rebranchez le système à la prise secteur et mettez-le sous tension, ainsi que les périphériques qui y sont connectés. 11. Attribuez un nouveau mot de passe système et/ou de configuration. 1107 Caractéristiques techniques Processeur Type de processeur Un ou deux processeurs Intel Xeon de la famille E5-2600 Bus d'extension Type de bus Génération PCI Express 3 Logements d'extension dotés de cartes de montage : Carte de montage 1 (Logement 1) Un demi hauteur, demi-longueur lien x8 (Logement 2) Un demi hauteur, demi-longueur lien x16 Carte de montage 2 (Logement 1) Un demi hauteur, demi longueur lien x8 ou un demi hauteur, demi longueur lien x16 REMARQUE: Les deux processeurs doivent être installés pour utiliser les logements qui se trouvent sur la carte de montage 1 et le lien x16 qui se trouve sur la carte de montage 2. Carte de montage 3 (Logement 1) Un pleine hauteur, longueur trois quart lien x16 ou un demi hauteur, demi longueur lien x16 Mémoire Architecture 1066 MT/s, 1333 MT/s, ou 1600 MT/s ECC (code correcteur d'erreurs) DIMM enregistrés ou non tamponnés Prise en charge ECC avancée ou opération de mémoire optimisée. Supports de barrette de mémoire Vingt-quatre supports à 240 broches Capacités de la barrette de mémoire LRDIMM 8 Go, 16 Go, ou 32 Go classés individuellement, par deux ou par quatre. Barrette RDIMM 2 Go, 4 Go, 8 Go, ou 32 Go classés individuellement, par deux ou par quatre 16 Go classés individuellement ou par deux UDIMM 2 Go, 4 Go ou 8 Go RAM minimale 2 Go avec un processeur individuel 4 Go avec deux processeurs 111Mémoire RAM maximale LRDIMM Jusqu'à 768 Go Barrette RDIMM Jusqu'à 512 Go UDIMM Jusqu'à 128 Go Drives (Lecteurs) Disques durs Jusqu'à quatre disques durs SAS, SATA ou Nearline SAS de 2,5 pouces, internes, échangeables à chaud REMARQUE: Les systèmes à quatre disques durs prennent en charge le RAID logiciel. Pour en savoir plus sur le RAID logiciel, reportez-vous à la documentation du PERC (Contrôleur RAID Dell PowerEdge) à l'adresse suivante : support.dell.com/ manuals. Lecteur optique Un lecteur DVD-ROM ou DVD+/-RW SATA en option REMARQUE: Les périphériques DVD sont uniquement des périphériques de données. Connecteurs Arrière Carte réseau Quatre 10/100/1000 Mb/s ou deux 10/100/1000 Mb/s et deux 100 Mb/s/1 Gb/s/10 Gb/s Série Connecteur DTE à 9 broches, compatible 16550 USB Deux connecteurs à 4 broches, compatibles USB 2.0 Vidéo Connecteur VGA à 15 broches Avant USB Deux connecteurs à 4 broches, compatibles USB 2.0 Vidéo Connecteur VGA à 15 broches Carte vFlash externe Logement de la carte mémoire vFlash REMARQUE: Le logement de la carte est disponible uniquement si la licence iDRAC7 Enterprise est installée sur votre système. Interne USB Un connecteur à 4 broches, compatible USB 2.0 Module SD interne double (en option) Deux logements pour carte mémoire flash, en option, avec le module interne SD (Secure Digital) 112Connecteurs REMARQUE: Un logement de carte est réservé à la redondance. Vidéo Type de vidéo Matrox G200 intégré Mémoire vidéo 16 Mo partagés Conditions environnementales REMARQUE: Pour en savoir plus sur les mesures d'exploitation liées à différentes configurations particulières, rendez-vous sur dell.com/environmental_datasheets. Température de fonctionnement standard Fonctionnement continu : de 10 à 35 °C avec une humidité relative (HR) de 10 à 80 %, avec point de condensation maximum à 26 °C. Réduction maximale admissible de la température sèche de 1 °C/300 mètres au-dessus de 900 mètres (1 °F tous les 550 pieds). Température de stockage De -40 à 65 °C (–40 °à 149 °F) avec un gradient thermique maximal de 20 °C par heure. Fonctionnement dans la plage de température étendue REMARQUE: Lorsque le système fonctionne dans la plage de température étendue, ses performances peut s'en voir affectées. REMARQUE: En cas de fonctionnement dans la plage de température étendue, des avertissements de température ambiante peuvent être reportés sur l'écran LCD et dans le journal des événements système. ≤10 % des heures de fonctionnement annuelles De 5 °C à 40 °C entre 5 et 85 % d'humidité relative, avec un point de condensation de 26 °C. REMARQUE: Si le système se trouve hors de la plage de températures de fonctionnement standard (10 °C à 35 °C), il peut réduire sa température de fonctionnement à 5 °C ou l'augmenter jusqu'à 40 °C pendant un maximum de 10 % de ses heures de fonctionnement annuelles. Pour les températures comprises entre 35 °C et 40 °C, la réduction maximale autorisée de la température sèche est de 1 °C tous les 175 m au-dessus de 950 m (1 °F tous les 319 pieds). ≤1 % des heures de fonctionnement annuelles De -5 à 45 °C entre 5 et 90 % d'humidité relative, avec un point de condensation de 26 °C. 113Conditions environnementales REMARQUE: Si le système se trouve hors de la plage de températures de fonctionnement standard (10 à 35 °C), il peut réduire sa température de fonctionnement à -5 °C ou l'augmenter jusqu'à 45 °C pendant un maximum de 1 % de ses heures de fonctionnement annuelles. Pour les températures comprises entre 40 et 45 °C, la réduction maximale autorisée de la température sèche est de 1 °C par 125 m au-dessus de 950 m (1 °F tous les 228 pieds). Restrictions de la température étendue de fonctionnement • N'effectuez pas de démarrage à froid en dessous de 5 °C. • La température de fonctionnement spécifiée correspond à une altitude maximale de 3 050 mètres (10 000 pieds). • Carte GPU non prise en charge • Les processeurs de 130 W (à 4 noyaux) et de 135 W ne sont pas pris en charge • Des blocs d'alimentation redondants sont requis • Les cartes de périphériques non autorisées par Dell et/ou les cartes de périphériques supérieures à 25 W ne sont pas prises en charge 1148 Messages système Messages LCD REMARQUE: Seulement applicable si votre système a un affichage d'écran LCD. Les messages affichés sur l'écran LCD sont des messages textes brefs qui renvoient à des événements enregistrés dans le journal des événements système (SEL). Pour plus d'informations sur le SEL et sur les paramètres de configuration de la gestion du système, reportez-vous à la documentation du logiciel de gestion des systèmes. REMARQUE: Si votre système ne démarre pas, maintenez le bouton de l'ID système enfoncé pendant au moins 5 secondes jusqu'à ce que le code d'erreur s'affiche sur l'écran LCD. Prenez le code en note, puis consultez la section Messages d'erreur du système. Affichage des messages sur l'écran LCD Si une erreur du système survient, l'écran LCD devient orange. Appuyez sur le bouton Sélectionner pour afficher une liste des messages d'erreur ou de conditions. Utilisez les boutons de gauche et de droite pour surligner un numéro d'erreur, puis appuyez sur le bouton Sélectionner pour afficher l'erreur. Suppression des messages affichés sur l'écran LCD Pour les pannes associées aux capteurs, telles que la température, la tension, les ventilateurs, etc. le message affiché sur l'écran LCD est automatiquement supprimé lorsque le capteur retourne à un état normal. Pour les autres types de pannes, vous devez supprimer le message affiché sur l'écran : • Clear the SEL (Effacer le journal d'événements système) : vous pouvez effectuer cette tâche à distance, mais vous perdrez alors la totalité de l'historique des événements système. • Power cycle (Cycle d'alimentation) : mettez le système hors tension et débranchez-le de la prise secteur. Attendez environ 10 secondes, puis rebranchez le câble d'alimentation et redémarrez le système. Messages d'erreur du système Le système affiche des messages d'erreur pour informer l'utilisateur qu'un incident s'est produit. Les messages qui s'affichent sur cet écran se rapportent aux événements consignés dans le journal d'événements du système (SEL).Pour plus d'informations sur ce journal et sur la configuration des paramètres de gestion du système, consultez la documentation du logiciel de gestion des systèmes. Certains messages sont également affichés sous une forme abrégée sur l'écran LCD du système, si le système comprend cette fonctionnalité. REMARQUE: Les messages d'erreur LCD suivants s'affichent sous format simple. Reportez-vous à la section Menu de configuration pour sélectionner le format dans lequel les messages sont affichés. 115REMARQUE: Si vous recevez du système un message qui n'est pas répertorié dans la liste ci-dessous, vérifiez la documentation de l'application que vous utilisiez au moment où le message est apparu. Vous pouvez aussi vous reporter à la documentation du système d'exploitation pour obtenir une explication du message et l'action conseillée. REMARQUE: Dans certains messages, un composant système particulier est identifié par nom (« »), numéro de composant (« ») or emplacement (« baie »). Code d'erreur Informations des messages AMP0302 Message The system board current is greater than the upper warning threshold. (Le courant de la carte système est supérieur au seuil d'avertissement maximal.) Détails Le courant de la carte système ne se trouve pas dans les limites optimales. Action 1. Vérifiez la règle d'alimentation du système. 2. Vérifiez les pannes liées à l'alimentation dans les journaux du système. 3. Vérifiez les modifications de configuration du système. 4. Si le problème persiste, reportez-vous à la section Obtention d'aide. AMP0303 Message The system board current is greater than the upper critical threshold. (Le courant de la carte système est supérieur au seuil critique maximal.) Message sur l'écran LCD System board current is outside of range. (Le courant de la carte système ne se trouve pas dans les limites.) Détails Le courant de la carte système ne se trouve pas dans les limites optimales. Action 1. Vérifiez la règle d'alimentation du système. 2. Vérifiez les pannes liées à l'alimentation dans les journaux du système. 3. Vérifiez les modifications de configuration du système. 4. Si le problème persiste, reportez-vous à la section Obtention d'aide. ASR0000 Message The watchdog timer expired. (Le registre d'horloge de la surveillance a expiré.) Détails Le système d'exploitation ou une application n'a pas réussi à communiquer au cours du délai imparti. Action Vérifiez le journal des événements du système d'exploitation, de l'application, du matériel et du système pour trouver des événements de l'exception. ASR0001 Message The watchdog timer reset the system. (Le registre d'horloge de la surveillance a réinitialisé le système.) Détails Le système d'exploitation ou une application n'a pas réussi à communiquer au cours du délai imparti. Le système a été réinitialisé. 116Code d'erreur Informations des messages Action Vérifiez le journal des événements du système d'exploitation, de l'application, du matériel et du système pour trouver des événements de l'exception. ASR0002 Message The watchdog timer powered off the system. (Le registre d'horloge de la surveillance a mis le système hors tension.) Détails Le système d'exploitation ou une application n'a pas réussi à communiquer au cours du délai imparti. Le système a été mis hors tension. Action Vérifiez le journal des événements du système d'exploitation, de l'application, du matériel et du système pour trouver des événements de l'exception. ASR0003 Message The watchdog timer power cycled the system. (Le registre d'horloge de la surveillance a coupé puis rétabli l'alimentation du système.) Détails Le système d'exploitation ou une application n'a pas réussi à communiquer au cours du délai imparti. L'alimentation du système a été coupée puis rétablie. Action Vérifiez le journal des événements du système d'exploitation, de l'application, du matériel et du système pour trouver des événements de l'exception. BAT0002 Message The system board battery has failed. (Défaillance de la pile de la carte système.) Message sur l'écran LCD The system board battery has failed. Check battery. (La pile de la carte système est défectueuse. Vérifiez la pile.) Détails La pile de la carte système est manquante ou défectueuse. Action Reportez-vous à la section Obtention d'aide. BAT0017 Message The battery has failed. (Défaillance de la batterie .) Message sur l'écran LCD The battery has failed. Check battery. (La batterie est défaillante. Vérifiez la batterie.) Détails La batterie est soit manquante, défectueuse ou incapable de charger suite à des problèmes thermiques. Action Vérifiez les ventilateurs du système. Si le problème persiste, reportez-vous à la section Obtention d'aide. CPU0000 Message CPU has an internal error (IERR). (L'UC est confrontée à une erreur interne (IERR).) Message sur l'écran LCD CPU has an internal error (IERR). (L'UC est confrontée à une erreur interne (IERR).) Détails Le journal des événements système et les journaux du système d'exploitation peuvent indiquer que l'exception est externe au processeur. 117Code d'erreur Informations des messages Action Examinez le journal des événements système et les journaux du système d'exploitation. Si le problème persiste, reportez-vous à la section Obtention d'aide. CPU0001 Message CPU has a thermal trip (over-temperature) event. (Événement de déclenchement thermique de l'UC (surchauffe).) Message sur l'écran LCD CPU has a thermal trip. Check CPU heat sink. (Déclenchement thermique de l'UC . Vérifiez le dissipateur de chaleur de l'UC.) Détails La température du processeur a augmenté au delà des limites opérationnelles. Action Cherchez une panne de ventilateur dans les journaux. Si aucune panne de ventilateur n'est détectée, vérifiez la température d'entrée (si elle est disponible) et réinstallez le dissipateur de chaleur du processeur. Si le problème persiste, reportez-vous à la section Obtention d'aide. CPU0005 Message CPU configuration is unsupported. (Configuration de l'UC non prise en charge.) Message sur l'écran LCD CPU configuration is unsupported. Check CPU or BIOS revision. (Configuration de l'UC non prise en charge. Vérifiez l'UC ou la révision du BIOS.) Détails Le système est incapable de démarrer ou risque de fonctionner dans un état dégradé. Action Examinez les caractéristiques techniques des types de processeurs pris en charge. CPU0010 Message CPU is throttled. (Les performances de l'UC sont réduites.) Détails Les performances de l'UC sont réduites suite à des conditions thermiques ou d'alimentation. Action Examinez les journaux système pour détecter des exceptions d'alimentation ou thermiques. CPU0023 Message CPU is absent. (L'UC est absente.) Message sur l'écran LCD CPU is absent. Check CPU. (L'UC est absente.Vérifiez l'UC.) Action Vérifiez l'installation du processeur. Réinsérez le processeur, si ce dernier est présent. CPU0204 Message CPU voltage is outside of range. (La tension de l'UC ne se trouve pas dans les limites.) Message sur l'écran LCD CPU voltage is outside of range. Re-seat CPU. (La tension de l'UC ne se trouve pas dans les limites.) 118Code d'erreur Informations des messages Détails Les tensions ne se trouvant pas dans les limites autorisées peuvent endommager les composants électroniques ou provoquer la mise hors tension du système. Action 1. Mettez le système hors tension puis supprimez l'alimentation d'entrée pendant une minute. 2. Vérifiez que le processeur est correctement inséré. 3. Réappliquez la puissance d'entrée et allumez le système. 4. Si le problème persiste, reportez-vous à la section Obtention d'aide. CPU0700 Message CPU initialization error detected. (Détection d'une erreur d'initialisation de l'UC .) Message sur l'écran LCD CPU initialization error detected. Power cycle system. (Détection d'une erreur d'initialisation de l'UC . Coupez puis rétablissez l'alimentation du système.) Détails Le BIOS du système n'a pas réussi à initialiser le processeur. Action 1. Mettez le système hors tension puis supprimez l'alimentation d'entrée pendant une minute. 2. Vérifiez que le processeur est correctement inséré. 3. Réappliquez la puissance d'entrée et allumez le système. 4. Si le problème persiste, reportez-vous à la section Obtention d'aide. CPU0701 Message CPU protocol error detected. (Détection d'une erreur de protocole de l'UC .) Message sur l'écran LCD CPU protocol error detected. Power cycle system. (Détection d'une erreur de protocole de l'UC . Coupez puis rétablissez l'alimentation du système.) Détails Le journal des événements système et les journaux du système d'exploitation peuvent indiquer que l'exception est externe au processeur. Action 1. Contrôlez les journaux du système et du système d'exploitation pour détecter des exceptions. Si aucune exception n'est détectée, continuez. 2. Mettez le système hors tension puis supprimez l'alimentation d'entrée pendant une minute. 3. Vérifiez que le processeur est correctement inséré. 4. Réappliquez la puissance d'entrée et allumez le système. 5. Si le problème persiste, reportez-vous à la section Obtention d'aide. CPU0702 Message CPU bus parity error detected. (Détection d'une erreur de parité du bus de l'UC.) 119Code d'erreur Informations des messages Message sur l'écran LCD CPU bus parity error detected. Power cycle system. (Détection d'une erreur de parité du bus de l'UC. Coupez puis rétablissez l'alimentation du système.) Détails Le journal des événements système et les journaux du système d'exploitation peuvent indiquer que l'exception est externe au processeur. Action 1. Contrôlez les journaux du système et du système d'exploitation pour détecter des exceptions. Si aucune exception n'est détectée, continuez. 2. Mettez le système hors tension puis supprimez l'alimentation d'entrée pendant une minute. 3. Vérifiez que le processeur est correctement inséré. 4. Réappliquez la puissance d'entrée et allumez le système. 5. Si le problème persiste, reportez-vous à la section Obtention d'aide. CPU0703 Message CPU bus initialization error detected. (Détection d'une erreur d'initialisation du bus de l'UC.) Message sur l'écran LCD CPU bus initialization error detected. Power cycle system. (Détection d'une erreur d'initialisation du bus de l'UC. Coupez puis rétablissez l'alimentation du système.) Détails Le journal des événements système et les journaux du système d'exploitation peuvent indiquer que l'exception est externe au processeur. Action 1. Contrôlez les journaux du système et du système d'exploitation pour détecter des exceptions. Si aucune exception n'est détectée, continuez. 2. Mettez le système hors tension puis supprimez l'alimentation d'entrée pendant une minute. 3. Vérifiez que le processeur est correctement inséré. 4. Réappliquez la puissance d'entrée et allumez le système. 5. Si le problème persiste, reportez-vous à la section Obtention d'aide. CPU0704 Message CPU machine check error detected. (Détection d'une erreur de vérification de l'ordinateur de l'UC .) Message sur l'écran LCD CPU machine check error detected. Power cycle system. (Détection d'une erreur de vérification de l'ordinateur de l'UC . Coupez puis rétablissez l'alimentation du système.) Détails Le journal des événements système et les journaux du système d'exploitation peuvent indiquer que l'exception est externe au processeur. Action 1. Contrôlez les journaux du système et du système d'exploitation pour détecter des exceptions. Si aucune exception n'est détectée, continuez. 2. Mettez le système hors tension puis supprimez l'alimentation d'entrée pendant une minute. 3. Vérifiez que le processeur est correctement inséré. 4. Réappliquez la puissance d'entrée et allumez le système. 120Code d'erreur Informations des messages 5. Si le problème persiste, reportez-vous à la section Obtention d'aide. VENTILATEUR0000 Message CPU temperature is less than the lower warning threshold. (La température de l'UC est inférieure au seuil d'avertissement minimal.) Détails La vitesse du ventilateur en fonction est hors d'atteinte. Action Retirez puis installez de nouveau le bloc d'alimentation. Si le problème persiste, reportez-vous à la section Obtention d'aide. VENTILATEUR0001 Message CPU temperature is less than the lower warning threshold. (La température de l'UC est inférieure au seuil d'avertissement minimal.) Message sur l'écran LCD Les rotations par minute du ventilateur sont hors d'atteinte. Vérifiez le ventilateur. Détails La vitesse du ventilateur en fonction est hors d'atteinte. Action Retirez puis installez de nouveau le ventilateur. Si le problème persiste, reportez-vous à la section Obtention d'aide. VENTILATEUR1201 Message La redondance du ventilateur est perdue. Message sur l'écran LCD La redondance du ventilateur est perdue. Vérifiez les ventilateurs. Détails Le ventilateur est tombé en panne. Action Enlevez et réinstallez les ventilateurs qui sont en panne ou installez des ventilateurs supplémentaires. HWC1001 Message The is absent. ( est manquant.) Message sur l'écran LCD The is absent. Check hardware. ( est manquant. Vérifiez le matériel.) Détails Le périphérique manquant peut être nécessaire pour un fonctionnement correct. Les fonctionnalités du système peuvent être dégradées. Action Réinstallez ou rebranchez le matériel. HWC2003 Message Le câble de stockage nom n'est pas branché, ou n'est pas branché correctement. Message sur l'écran LCD Câble de stockage ou panne d'interconnexion. Vérifiez la connexion. Détails Le câble peut être nécessaire pour un fonctionnement correct. Les fonctionnalités du système peuvent être dégradées. Action Vérifiez si le câble est présent, ensuite réinstallez-le ou reconnectez-le. 121Code d'erreur Informations des messages HWC2005 Message Le câble de la carte système n'est pas connecté ou n'est pas correctement connecté. Message sur l'écran LCD La connexion du câble de la carte système est en panne. Vérifiez la connexion. Détails Le câble peut être nécessaire pour un fonctionnement correct. Les fonctionnalités du système peuvent être dégradées. Action Vérifiez si le câble est présent, ensuite réinstallez-le ou reconnectez-le. MEM0000 Message Persistent correctable memory errors detected on a memory device at location(s) . (Détection d'erreurs de la mémoire permanente corrigibles sur un périphérique mémoire de l'emplacement .) Détails Il s'agit d'un premier indicateur d'une éventuelle erreur non corrigible future. Action Réinsérez les barrettes de mémoire. Si le problème persiste, reportez-vous à la section Obtention d'aide. MEM0001 Message Multi-bit memory errors detected on a memory device at location(s) . (Détection d'erreurs de mémoire multi-bits sur un périphérique mémoire de l'emplacement .) Message sur l'écran LCD Multi-bit memory error on . Re-seat memory. (Erreur de mémoire multi-bits sur .) Détails La barrette de mémoire a été victime d'une erreur non corrigible. Les performances du système peuvent être dégradées. Par conséquent, le système d'exploitation et/ou les applications peuvent tomber en panne. Action Réinsérez les barrettes de mémoire. Si le problème persiste, reportez-vous à la section Obtention d'aide. MEM0007 Message Unsupported memory configuration; check memory device at location . (Configuration de mémoire non prise en charge, vérifiez le périphérique mémoire à l'emplacement .) Message sur l'écran LCD Unsupported memory configuration. Check memory . (Configuration de mémoire non prise en charge. Vérifiez la mémoire de .) Détails La mémoire n'est peut-être pas insérée ou configurée correctement ou est défectueuse. La taille de la mémoire est réduite. Action Vérifiez la configuration de la mémoire. Réinsérez les barrettes de mémoire. Si le problème persiste, reportez-vous à la section Obtention d'aide. MEM0701 Message Correctable memory error rate exceeded for . (Seuil d'erreurs de mémoire corrigibles dépassé pour .) 122Code d'erreur Informations des messages Détails La mémoire peut ne pas être opérationnelle. Il s'agit d'un premier indicateur d'une éventuelle erreur non corrigible future. Action Réinsérez les barrettes de mémoire. Si le problème persiste, reportez-vous à la section Obtention d'aide . MEM0702 Message Correctable memory error rate exceeded for . (Seuil d'erreurs de mémoire corrigibles dépassé pour .) Message sur l'écran LCD Correctable memory error rate exceeded for . Re-seat memory. (Seuil d'erreurs de mémoire corrigibles dépassé pour . Réinsérez la mémoire.) Détails La mémoire peut ne pas être opérationnelle. Il s'agit d'un premier indicateur d'une éventuelle erreur non corrigible future. Action Réinsérez les barrettes de mémoire. Si le problème persiste, reportez-vous à la section Obtention d'aide. MEM1205 Message Memory mirror redundancy is lost. Check memory device at location(s) . (La redondance de la mise en miroir de la mémoire est perdue. Vérifiez les périphériques mémoire sur .) Message sur l'écran LCD Memory mirror lost on . Power cycle system. (La mise en miroir de la mémoire est perdue sur . Coupez puis rétablissez l'alimentation du système.) Détails La mémoire peut être mal insérée, mal configurée ou défectueuse. Action Vérifiez la configuration de la mémoire. Réinsérez les barrettes de mémoire. Si le problème persiste, reportez-vous à la section Obtention d'aide. MEM1208 Message Memory spare redundancy is lost. Check memory device at location . (La redondance de la mémoire de secours est perdue. Vérifiez les périphériques mémoire sur .) Message sur l'écran LCD Memory spare lost on . Power cycle system. (La mémoire de secours est perdue sur . Coupez puis rétablissez l'alimentation du système.) Détails La mémoire de secours n'est plus disponible. Action Réinsérez les barrettes de mémoire. Si le problème persiste, reportez-vous à la section Obtention d'aide. MEM8000 Message Correctable memory error logging disabled for a memory device at location . (Désactivation de la journalisation des erreurs de la mémoire permanente corrigeable pour un périphérique mémoire de l'emplacement .) 123Code d'erreur Informations des messages Message sur l'écran LCD SBE log disabled on . Re-seat memory. (Désactivation du journal des erreurs portant sur un seul bit sur . Réinsérez la mémoire.) Détails Les erreurs sont corrigées mais ne sont plus reportées dans le journal. Action Examinez les journaux du système pour détecter les exceptions de mémoire. Réinstallez la mémoire sur l'emplacement . PCI1302 Message A bus time-out was detected on a component at bus devicefunction . (Détection d'une expiration du délai du bus sur un composant du bus du périphérique de la fonction .) Détails Les performances du système peuvent être dégradées. Le périphérique ne répond pas à une transaction. Action Coupez puis rétablissez l'alimentation, mettez à jour les pilotes du composant. Si le périphérique est amovible, réinstallez le périphérique. PCI1304 Message An I/O channel check error was detected. (Détection d'une erreur de vérification du canal d'E/S.) Message sur l'écran LCD I/O channel check error detected. Power cycle system. (Détection d'une erreur de vérification du canal d'E/S. Coupez puis rétablissez l'alimentation système.) Action Coupez puis rétablissez l'alimentation, mettez à jour les pilotes du composant. Si le périphérique est amovible, réinstallez le périphérique. PCI1308 Message A PCI parity error was detected on a component at bus devicefunction . (Détection d'une erreur de parité PCI sur un composant du bus du périphérique de la fonction .) Message sur l'écran LCD PCI parity error on bus device function . Power cycle system. (Erreur de parité PCI sur le bus le périphérique la fonction .) Détails Les performances du système peuvent être dégradées, le périphérique PCI ou le système peut ne pas fonctionner. Action Coupez puis rétablissez l'alimentation, mettez à jour les pilotes du composant. Si le périphérique est amovible, réinstallez le périphérique. PCI1320 Message A bus fatal error was detected on a component at bus devicefunction . (Détection d'une erreur fatale de bus sur un composant du bus du périphérique de la fonction .) 124Code d'erreur Informations des messages Message sur l'écran LCD Bus fatal error on bus device function . Power cycle system. (Erreur fatale de bus sur le bus le périphérique la fonction .) Détails Les performances du système peuvent être dégradées ou le système peut ne pas fonctionner. Action Coupez puis rétablissez l'alimentation, mettez à jour les pilotes du composant. Si le périphérique est amovible, réinstallez le périphérique. PCI1342 Message A bus time-out was detected on a component at slot . (Détection d'une expiration de délai de bus sur un composant du logement .) Détails Les performances du système peuvent être dégradées ou le système peut ne pas fonctionner. Action Coupez puis rétablissez l'alimentation, mettez à jour les pilotes du composant. Si le périphérique est amovible, réinstallez le périphérique. PCI1348 Message A PCI parity error was detected on a component at slot . (Détection d'une erreur de parité PCI sur un composant du logement .) Message sur l'écran LCD PCI parity error on slot . Re-seat PCI card. (Erreur de parité PCI du logement . Réinsérez le PCI.) Détails Les performances du système peuvent être dégradées ou le système peut ne pas fonctionner. Action Coupez puis rétablissez l'alimentation, mettez à jour les pilotes du composant. Si le périphérique est amovible, réinstallez le périphérique. PCI1360 Message A bus fatal error was detected on a component at slot . (Détection d'une erreur fatale de bus sur un composant du logement .) Message sur l'écran LCD Bus fatal error on slot . Re-seat PCI card. (Erreur fatale de bus du logement . Réinsérez la carte PCI.) Détails Les performances du système peuvent être dégradées ou le système peut ne pas fonctionner. Action Coupez puis rétablissez l'alimentation, mettez à jour les pilotes du composant. Si le périphérique est amovible, réinstallez le périphérique. PDR0001 Message Fault detected on drive . (Panne détectée dans le lecteur .) Message sur l'écran LCD Fault detected on drive . Check drive. (Panne détectée dans le lecteur . Vérifiez le lecteur.) Détails Le contrôleur a détecté une panne du disque et a mis le disque hors ligne. 125Code d'erreur Informations des messages Action Retirez puis réinsérez le disque en panne. Si le problème persiste, reportez-vous à la section Obtention d'aide. PDR1016 Message Drive is removed from disk drive bay . (Retrait du lecteur de la baie de lecteur de disque dur .) Message sur l'écran LCD Drive removed from disk drive bay . Check drive. (Retrait du lecteur de la baie de lecteur de disque dur . Vérifiez le lecteur.) Détails Le contrôleur a détecté que le lecteur avait été retiré. Action Vérifiez l'installation du lecteur. Réinsérez le lecteur défectueux. Si le problème persiste, reportez-vous à Obtention d'aide. PST0128 Message No memory is detected. (Pas de mémoire détectée.) Message sur l'écran LCD No memory is detected. Inspect memory devices. (Pas de mémoire détectée. Contrôlez les périphériques mémoire.) Détails Le BIOS du système n'a pas été capable de détecter la mémoire dans le système. Action Réinsérez les barrettes de mémoire. Si le problème persiste, reportezvous à la section Obtention d'aide. PST0129 Message Memory is detected, but is not configurable. (Mémoire détectée, mais non configurable.) Message sur l'écran LCD Memory is detected, but is not configurable. Check memory devices. (Mémoire détectée, mais non configurable. Vérifiez les périphériques mémoire.) Détails Le BIOS du système a détecté la mémoire mais a été incapable de configurer la mémoire pour le fonctionnement du système. Action Comparez l'installation de la mémoire du système avec les configurations de mémoire du système prises en charge. PSU0001 Message Power supply failed. (Panne du bloc d'alimentation .) Message sur l'écran LCD PSU failed. Check PSU. (Panne du bloc d'alimentation . Vérifiez le bloc d'alimentation.) Action Retirez puis installez de nouveau le bloc d'alimentation. Si le problème persiste, reportez-vous à la section Obtention d'aide. PSU0002 Message A predictive failure detected on power supply . (Détection d'une panne prévisible sur le bloc d'alimentation .) Message sur l'écran LCD Predictive failure on PSU . Check PSU. (Panne prévisible sur le bloc d'alimentation . Vérifiez le bloc d'alimentation.) 126Code d'erreur Informations des messages Détails Les performances du système et la redondance de l'alimentation peuvent être dégradées ou perdues. Action Retirez puis installez de nouveau le bloc d'alimentation lors du prochain entretien. Si le problème persiste, reportez-vous à la section Obtention d'aide. PSU0003 Message The power input for power supply is lost. (Perte de l'entrée d'alimentation du bloc d'alimentation .) Message sur l'écran LCD Power input for PSU is lost. Check PSU cables. (Perte de l'entrée d'alimentation du bloc d'alimentation . Vérifiez le bloc d'alimentation.) Détails Le bloc d'alimentation est installé correctement mais une source d'alimentation n'est pas connectée ou n'est pas fonctionnelle. Action Vérifiez que la source d'alimentation est liée au bloc d'alimentation. Vérifiez que la source d'alimentation est conforme aux spécifications de fonctionnement du bloc d'alimentation. PSU0006 Message Power supply type mismatch. (Non correspondance du type de bloc d'alimentation .) Message sur l'écran LCD Power supply is incorrectly configured. Check PSU. (Le bloc d'alimentation n'est pas configuré correctement. Vérifiez le bloc d'alimentation.) Détails Les blocs d'alimentation doivent être de même type d'alimentation et de puissance. Action Installez des blocs d'alimentation correspondants et vérifiez la configuration à utiliser dans ce manuel. PSU0016 Message Power supply is absent. (Le bloc d'alimentation est manquant.) Message sur l'écran LCD PSU is absent. Check PSU. (Le bloc d'alimentation est manquant. Vérifiez le bloc d'alimentation.) Détails Le bloc d'alimentation a été retiré ou est défectueux. Action 1. Retirez puis installez de nouveau le bloc d'alimentation. 2. Vérifiez que les câbles et les composants du sous-système ne sont pas endommagés. 3. Si le problème persiste, reportez-vous à la section Obtention d'aide. PSU0031 Message Cannot communicate with power supply . (Impossible de communiquer avec le bloc d'alimentation .) 127Code d'erreur Informations des messages Message sur l'écran LCD Cannot communicate with PSU . Re-seat PSU. (Impossible de communiquer avec le bloc d'alimentation . Réinsérez le bloc d'alimentation.) Détails Le bloc d'alimentation peut fonctionner, toutefois le contrôle du bloc d'alimentation sera dégradé. Les performances du système peuvent être dégradées. Action Retirez puis installez de nouveau le bloc d'alimentation. Si le problème persiste, reportez-vous à la section Obtention d'aide. PSU0032 Message The temperature for power supply is in a warning range. (La température pour l'alimentation est dans une plage d'avertissement). Détails Les performances du système peuvent être dégradées. Action Vérifiez l'environnement de fonctionnement système, notamment le débit d'air et la température d'entrée. Vérifiez les journaux du système pour les pannes de température et de composant thermique. PSU0033 Message The temperature for power supply is outside of the allowable range. (La température pour l'alimentation est en dehors de la plage autorisée). Message sur l'écran LCD PSU temperature outside of range. Check PSU. (La température du PSU est en dehors de la plage. Vérifiez le PSU). Détails Les performances du système peuvent être dégradées. Action Vérifiez l'environnement de fonctionnement système, notamment le débit d'air et la température d'entrée. Recherchez une panne de température et de composant thermique dans les journaux du système. PSU0034 Message An under voltage fault detected on power supply . (Un défaut de sous-tension a été détecté sur l'alimentation ). Message sur l'écran LCD An under voltage fault detected on PSU . Check power source. (Un défaut de sous-tension a été détecté sur le PSU . Vérifiez l'alimentation.) Détails Cette panne peut être le résultat d'un problème électrique lié aux câbles ou aux composants d'un sous-système dans le système. Action 1. Retirez puis installez de nouveau le bloc d'alimentation. 2. Vérifiez que les câbles et les composants du sous-système ne sont pas endommagés. 3. Si le problème persiste, reportez-vous à Getting Help (Obtention d'aide). PSU0035 Message An over voltage fault detected on power supply . (Un défaut de surtension a été détecté sur l'alimentation ). 128Code d'erreur Informations des messages Message sur l'écran LCD Over voltage fault on PSU . Check PSU. (Un défaut de surtension sur le PSU . Vérifiez le PSU). Action Vérifiez l'alimentation. Installez de nouveau le bloc d'alimentation. Si le problème persiste, reportez-vous à la section Obtention d'aide. PSU0036 Message An over current fault detected on power supply . (Un défaut de surintensité a été détecté sur l'alimentation ). Message sur l'écran LCD An over current fault detected on PSU . Check PSU. (Un défaut de surintensité a été détecté sur le PSU . Vérifiez le PSU). Détails Cette panne peut être le résultat d'un problème électrique lié aux câbles ou aux composants d'un sous-système dans le système. Action 1. Retirez puis installez de nouveau le bloc d'alimentation. 2. Vérifiez que les câbles et les composants du sous-système ne sont pas endommagés. 3. Si le problème persiste, reportez-vous à la section Obtention d'aide. PSU0037 Message Fan failure detected on power supply . (Une panne de ventilateur a été détectée sur l'alimentation .) Message sur l'écran LCD Fan failure detected on PSU . Check PSU. (Une panne de ventilateur a été détectée sur le . Vérifiez le PSU). Action Vérifiez s'il y a un blocage de ventilateur. Si le problème persiste, reportezvous à la section Obtention d'aide. PSU0076 Message A power supply wattage mismatch is detected; power supply is rated for watts. (Un déséquilibre de la puissance d'alimentation a été détecté ; l'alimentation est évaluée pour watts.) Message sur l'écran LCD PSU wattage mismatch; PSU = watts (Déséquilibre de puissance du PSU ; PSU = watts) Détails Les blocs d'alimentation doivent être de même type d'alimentation et de puissance. Action Installez les alimentations appariées et révisez ce manuel pour une configuration correcte. PSU1201 Message Power supply redundancy is lost. (Perte de la redondance du bloc d'alimentation.) Détails Le bloc d'alimentation tentera de fonctionner dans un état dégradé. Les performances du système et la redondance de l'alimentation peuvent être dégradées ou perdues. Action Vérifiez l'alimentation. Installez de nouveau le bloc d'alimentation. Si le problème persiste, reportez-vous à la section Obtention d'aide. 129Code d'erreur Informations des messages PSU1204 Message The power supplies are not redundant. Insufficient resources to maintain normal operations. (Les blocs d'alimentation ne sont pas redondants. Il n'y a pas suffisamment de ressources pour conserver un fonctionnement normal.) Message sur l'écran LCD PSU redundancy degraded. Check PSU cables. (Dégradation de la redondance du bloc d'alimentation. Vérifiez les câbles du bloc d'alimentation.) Détails Le mode de fonctionnement de l'alimentation n'est pas redondant à cause d'une exception de bloc d'alimentation, d'un changement de bloc d'alimentation ou d'alimentation du système. Action Examinez le journal des événements pour détecter des pannes de bloc d'alimentation. Vérifiez la configuration du système et la consommation électrique. PWR1004 Message The system performance degraded because power capacity has changed. (Dégradation des performances du système à cause d'une modification des capacités d'alimentation.) Détails Le système peut s'éteindre ou fonctionner dans un état dégradé. Action Examinez le journal des événements pour détecter des pannes de blocs d'alimentation. Vérifiez la configuration du système et la consommation électrique puis mettez à niveau ou installez les blocs d'alimentation en conséquence. PWR1005 Message The system performance degraded because the user-defined power capacity has changed. (Dégradation des performances du système à cause de la modification des capacités d'alimentation définies par l'utilisateur.) Détails Les paramètres d'alimentation définis par l'utilisateur ont affecté le fonctionnement du système. Action Si cela n'est pas prévu, vérifiez les modifications de configuration du système et les politiques d'alimentation. PWR1006 Message The system halted because system power exceeds capacity. (Arrêt du système car la puissance du système dépasse la capacité.) Message sur l'écran LCD System power demand exceeds capacity. System halted. (La demande de puissance du système dépasse la capacité. Arrêt du système.) Détails Arrêt du système car la puissance du système dépasse la capacité. Action Vérifiez la configuration du système, mettez à niveau les blocs d'alimentation ou réduisez la consommation de la puissance du système. RFM1008 Message Failure detected on Removable Flash Media . (Détection d'une erreur sur le support flash amovible .) Message sur l'écran LCD Removable Flash Media failed. Check SD Card. (Panne du support flash amovible . Vérifiez la carte SD). 130Code d'erreur Informations des messages Détails Une erreur est signalée au cours d'une lecture ou écriture de la carte SD. Action Réinitialisez le support flash. Si le problème persiste, reportez-vous à la section Obtention d'aide. RFM1014 Message Removable Flash Media is write protected. (Le support flash amovible est protégé en écriture.) Message sur l'écran LCD Removable Flash Media is write protected. Check SD Card. (Le support flash amovible est protégé en écriture. Vérifiez la carte SD.) Détails La carte est protégée en écriture par un loquet sur la carte SD. Une carte protégée en écriture ne peut pas être utilisée. Action Si cela n'est pas prévu, retirez le support et désactivez la protection en écriture. RFM1201 Message Internal Dual SD Module redundancy lost. (Perte de la redondance du module SD double interne.) Message sur l'écran LCD Internal Dual SD Module redundancy is lost. Check SD Card. (Perte de la redondance du module SD double interne. Vérifiez la carte SD.) Détails Une ou les deux cartes SD ne fonctionnent pas correctement. Action Reportez-vous à la section Obtention d'aide. RFM2001 Message Internal Dual SD Module is absent. (Le module SD double interne est manquant.) Message sur l'écran LCD Internal Dual SD Module is absent. Check SD Card. (Le module SD double interne est manquant. Vérifiez la carte SD.) Détails Le module de la carte SD n'est pas détecté ou n'est pas installé. Action Si cela n'est pas prévu, réinstallez le module de la carte SD. RFM2002 Message Internal Dual SD Module is offline. (Le module SD double interne est hors ligne.) Détails Le module de la carte SD est installé mais peut être mal installé ou mal configuré. Action Réinstallez le module de la carte SD. RFM2004 Message Failure detected on Internal Dual SD Module . (Détection d'une panne sur le module SD double interne .) Message sur l'écran LCD Internal Dual SD Module is failed. Check SD Card. (Panne du module SD double interne . Vérifiez la carte SD.) Détails Le module de la carte SD est installé mais n'est pas correctement configuré ou ne réussit pas à s'initialiser. 131Code d'erreur Informations des messages Action Réinstallez le module de la carte SD et retirez puis réinstallez les cartes SD. RFM2006 Message Internal Dual SD Module is write protected. (Le module SD double interne est protégé en écriture.) Détails Le module est protégé en écriture. Les modifications ne peuvent être écrites sur le support. Action Si cela n'est pas prévu, retirez le support et désactivez la protection en écriture. SEC0031 Message The chassis is open while the power is on. (Le châssis est ouvert alors que le système est sous tension.) Message sur l'écran LCD Intrusion detected. Check chassis cover. (Intrusion détectée. Vérifiez le capot du châssis.) Détails Le châssis est ouvert. Les performances du système peuvent être dégradées et la sécurité compromise. Action Fermez le châssis. Vérifiez les journaux système. SEC0033 Message The chassis is open while the power is off. (Le châssis est ouvert alors que le système est hors tension.) Message sur l'écran LCD Intrusion detected. Check chassis cover. (Intrusion détectée. Vérifiez le capot du châssis.) Détails Le châssis a été ouvert alors que le système est hors tension. La sécurité du système peut avoir été compromise. Action Fermez le châssis et vérifiez l'inventaire du matériel. Vérifiez les journaux système. SEL0006 Message All event logging is disabled. (Désactivation de la journalisation de tous les événements.) Détails Ce message s'affiche lorsque la journalisation de tous les événements a été désactivée par l'utilisateur. Action Si cela n'est pas prévu, activez de nouveau la journalisation. SEL0008 Message Log is full. (Le journal est plein.) Détails Lorsque le journal est plein, les événements supplémentaires ne sont pas écrits dans le journal. Les événements plus anciens peuvent être écrasés et perdus. Ce message peut également s'afficher si l'utilisateur désactive la journalisation des événements. Action Sauvegardez et effacez le journal. SEL0012 Message Could not create or initialize the system event log. (Impossible de créer ou d'initialiser le journal des événements système.) 132Code d'erreur Informations des messages Détails Si le journal des événements système n'arrive pas à s'initialiser, l'état de la plateforme et les événements ne peuvent pas être enregistrés. Certains logiciels de gestion ne rapportent pas les exceptions de plateforme. Action Redémarrez le contrôleur de gestion ou le contrôleur iDRAC. Coupez puis rétablissez l'alimentation du système. Si le problème persiste, contactez le service d'assistance. SEL1204 Message An unknown system hardware failure detected. (Détection d'une panne d'un matériel du système inconnue.) Message sur l'écran LCD Unknown system hardware failure. (Panne d'un matériel du système inconnue.) Détails Si le journal des événements système n'arrive pas à s'initialiser, l'état de la plateforme et les événements ne peuvent pas être enregistrés. Certains logiciels de gestion ne rapportent pas les exceptions de plateforme. Action Configurez à nouveau le système sur la configuration minimale prise en charge. Si le problème persiste, contactez le service d'assistance. TMP0118 Message The system inlet temperature is less than the lower warning threshold. (La température d'entrée du système est inférieure au seuil d'avertissement minimal.) Message sur l'écran LCD System inlet temperature is outside of range. (La température d'entrée du système ne se trouve pas dans les limites.) Détails La température de l'air ambiant est trop froide. Action Vérifiez l'environnement du système d'exploitation. TMP0119 Message The system inlet temperature is less than the lower critical threshold. (La température d'entrée du système est inférieure au seuil critique minimal.) Message sur l'écran LCD System inlet temperature is outside of range. (La température d'entrée du système ne se trouve pas dans les limites.) Détails La température de l'air ambiant est trop froide. Action Vérifiez l'environnement du système d'exploitation. TMP0120 Message The system inlet temperature is greater than the upper warning threshold. (La température d'entrée du système est supérieure au seuil d'avertissement maximal.) Message sur l'écran LCD System inlet temperature is outside of range. (La température d'entrée du système ne se trouve pas dans les limites.) Détails La température de l'air ambiant est trop chaude ou un ou plusieurs ventilateurs sont en panne. 133Code d'erreur Informations des messages Action Vérifiez l'environnement du système d'exploitation et examinez le journal des événements pour détecter des pannes de ventilateur. TMP0121 Message The system inlet temperature is greater than the upper critical threshold. (La température d'entrée du système est supérieure au seuil critique maximal.) Message sur l'écran LCD System inlet temperature is outside of range. Check Fans. (La température d'entrée du système ne se trouve pas dans les limites. Vérifiez les ventilateurs.) Détails La température de l'air ambiant est trop chaude ou un ou plusieurs ventilateurs sont en panne. Action Vérifiez l'environnement du système d'exploitation et examinez le journal des événements pour détecter des pannes de ventilateur. VLT0204 Message The system board voltage is outside of the allowable range. (La tension de la carte système se trouve en dehors des limites autorisées.) Message sur l'écran LCD System board voltage is outside of range. (La tension de la carte système se trouve en dehors des limites.) Détails Le matériel du système a détecté une surtension ou une sous-tension. Si des exceptions de tension multiple surviennent de manière consécutive, le système peut s'arrêter en mode de prévention de défaillance. Action 1. Examinez les journaux des événements pour détecter des exceptions d'alimentation. 2. Configurez à nouveau le système sur la configuration minimale, configurez puis réinstallez les câbles du système. 3. Si le problème persiste, reportez-vous à la section Obtention d'aide. Messages d'avertissement Un message d'avertissement vous alerte des éventuels problèmes et invites auxquels vous devez répondre avant que le système ne poursuive sa tâche. Par exemple, avant de formater un disque dur, un message vous avertit que vous pouvez perdre toutes les données se trouvant sur le disque dur. Les messages d'avertissement interrompent généralement la tâche et demande que vous répondiez en saisissez o (oui) ou n (non). REMARQUE: Les messages d'avertissement sont générés par l'application ou par le système d'exploitation. Pour en savoir plus, consultez la documentation fournie avec le système d'exploitation ou l'application. Messages de diagnostic Les utilitaires de diagnostic du système peuvent créer des messages si vous exécutez des tests de diagnostic sur le système. Reportez-vous à Running The Embedded System Diagnostics (Exécution des diagnostics intégrés du système) pour obtenir plus d'informations sur les diagnostics du système. 134Messages d'alerte Le logiciel de gestion des systèmes génère des messages d'alertes pour votre système. Les messages d'alerte comprennent des messages d'informations, d'états, d'avertissements et de panne relatifs à l'état du lecteur, de la température, du ventilateur et de l'alimentation. Pour obtenir plus d'information, reportez-vous à la documentation du logiciel de gestion des systèmes. 1351369 Obtention d'aide Contacter Dell REMARQUE: Si vous ne disposez pas d'une connexion Internet, les informations de contact figurent sur la facture d'achat, le borderau de colisage, la facture le catalogue des produits Dell. Dell propose diverses options d'assistance et de maintenance en ligne et téléphonique. Ces options varient en fonction du pays et du produit et certains services peuvent ne pas être disponibles dans votre région Pour contacter le service commercial, technique ou client de Dell : 1. Visitez le site support.dell.com. 2. Sélectionnez la catégorie d'assistance. 3. Si vous ne résidez pas aux Etats-Unis, sélectionnez le code pays au bas de la page support.dell.com ou sélectionnez Tout pour afficher d'autres choix. 4. Sélectionnez le lien de service ou d'assistance approprié. 137 Upgrading to BackupExec 2012 PowerVault DL Backup to Disk ApplianceContents EXECUTIVE SUMMARY..................................................................................................................................................... 3 UPGRADE NOTIFICATION................................................................................................................................................. 4 DL APPLIANCE RECOVERY AND UPDATE UTILITY REQUIREMENTS ..................................................................................... 6 UPGRADING TO BACKUP EXEC 2012................................................................................................................................. 7Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Executive Summary Since February 2010, the PowerVault DL Backup to Disk Appliance was integrated with Backup Exec 2010. Starting February 1 st , 2012, PowerVault DL Backup to Disk customers who are current on their Symantec Essential Support will be eligible to upgrade to Backup Exec 2012. Backup Exec 2012 introduces exciting new features such as enhanced virtual machine protection through Symantec’s v-Ray technology. For more details on these new features please visit http://www.backupexec.com. Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Upgrade Notification IMPORTANT NOTE: If you are currently running Backup Exec 12.5 or Backup Exec 2010 and plan on upgrading to Backup Exec 2012, Dell recommends not upgrading to Backup Exec 2012 until the new version of the Dell™ PowerVault™ DL Appliance Recovery and Update Utility (RUU) v3.5 is available in April. For more information, refer to the Backup Exec 2012 FAQ at http://entsupport.symantec.com/umi/V-269-53 Customers with current registered maintenance on the previous version of the Backup Exec DL Edition included with the PowerVault DL Backup to Disk appliance are entitled to Backup Exec 2012 free of charge as part of the maintenance subscription, and are authorized to upgrade to Symantec Backup Exec 2012. This is not a renewal of maintenance. 1. Customers who have registered their Backup Exec 2010 maintenance agreements with Symantec will receive a version upgrade notification letter with their Backup Exec 2012 license files and instructions for obtaining Backup Exec 2012 installation media. The upgrade notifications will be sent over a 12 week period starting in mid March 2012. 2. Using the information contained in the version upgrade letter, customers will be able to download the Backup Exec 2012 installation media from https://fileconnect.symantec.com 3. Customers should also register their new Backup Exec 2012 serial numbers with the Symantec Licensing Portal via https://licensing.symantec.com 4. Once the license files and installation media have been obtained, proceed to the installation instructions below. Customers who have not registered their maintenance agreements must register before they are eligible to upgrade to Backup Exec 2012. This can be done by visiting https://licensing.symantec.com and registering the Serial Number included on the serial number certificate provided at the time of purchase. If you have registered your maintenance and did not receive your version upgrade notification by June 1st, contact Symantec Customer Care for your region. Customer Care contact information can be found at http://www.symantec.com/business/support/assistance_care.jsp NOTE: Backup Exec 2012 will not accept Backup Exec 2010 license keysUpgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance About the Storage Provisioning Option license The Backup Exec Storage Provisioning Option (SPO) enables Backup Exec to configure, monitor and manage disks and disk arrays connected to the PowerVault DL Backup to Disk Appliance. SPO has the ability to automatically configure disks for backup to disk operations and deduplication capabilities in Backup Exec. Note that deduplication requires the Backup Exec Deduplication Option. The Storage Provisioning Option enables the configuration, monitoring and management of disks attached to the PowerVault DL Backup to Disk Appliance for backup and restore operations. There are no restrictions on the number of external disks or disks enclosures that can be configured using SPO. When upgrading to Backup Exec 2012, Backup Exec 12.5 Storage Provisioning Option licenses are mapped to Backup Exec 2012 Storage Provisioning Option Unlimited license keys. When upgrading from Backup Exec 2010, the respective storage provisioning license key will be converted. See description below for information on the Basic & Unlimited license key. • Backup Exec 2012 Storage Provisioning Option Basic – The Backup Exec 2012 Storage Provisioning Option Basic license key only supports the configuration, monitoring and management of disks internal to the PowerVault DL Backup to Disk Appliance head unit. If additional disks are in the form of external disk arrays are attached to the PowerVault DL Backup to Disk Appliance, the Backup Exec 2010 Storage Provisioning Option Unlimited license key is required to configure, monitor, and manage these external disk arrays. • Backup Exec 2012 Storage Provisioning Option Unlimited – The Backup Exec 2012 Storage Provisioning Option Unlimited license key supports the configuration, monitoring and management of disks internal to the PowerVault DL Backup to Disk Appliance head unit and disks in the form of external disk arrays attached to the PowerVault DL Backup to Disk Appliance.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance DL Appliance Recovery and Update Utility Requirements If you are currently running Backup Exec 12.5 or Backup Exec 2010 and plan on upgrading to Backup Exec 2012, Dell recommends not upgrading to Backup Exec 2012 until the new version of the Dell™ PowerVault™ DL Appliance Recovery and Update Utility (RUU) v3.5 is available in April. When upgrading to Backup Exec 2012, you must apply the licenses for Backup Exec 2012. If the licenses are not applied, then Backup Exec 2012 can be run in trial mode for 60 days, however you must ensure that the Storage Provisioning Option is installed during the upgrade. After 60 days, Storage Provisioning Option and prior backup jobs using virtual disks managed by the PERC controller will not work until the Backup Exec 2012 licenses are applied. If you upgrade to Backup Exec 2012 without applying the latest version of the RUU, the following functionality will be affected: • System Recovery of the DL Appliance using DL Backup to Disk Appliance Configuration Wizard o Details: Using the DL Backup to Disk Appliance Configuration Wizard to perform a system recovery of the DL Appliance will not work with Backup Exec 2012 media until it is updated to the latest version using the RUU v3.5 or later. o Recommendation: Ensure that the system is prepared for disaster recovery using Simplified Disaster Recovery (SDR). Refer to the Backup Exec 2012 Administrator’s Guide for more details. Existing IDR jobs are not converted to SDR jobs during migration. You can either edit your existing IDR jobs manually or you can create new SDR jobs after migration. Note that Agents for Windows must be updated before you can run new SDR jobs. For more information see the following technote http://entsupport.symantec.com/umi/V-269-51 • For full functionality of the DL Backup to Disk Appliance Console with Backup Exec 2012, the RUU v3.5 software stack is required. The following features will be unavailable in Appliance Console prior to loading RUU v3.5. Alternatively, the Backup Exec 2012 console can be used to retrieve the information. o Disk usage statistics o Backup Exec services status o The Appliance Role (Central Administration Server or Standalone server)Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Upgrading to Backup Exec 2012 IMPORTANT NOTE: During the upgrade to Backup Exec 2012 on the Dell DL2xxx system, do not run the Dell™ PowerVault™ DL Backup to Disk Appliance Console. Perform the following steps to upgrade your PowerVault DL Backup to Disk Appliance to Backup Exec 2012: 1. On the PowerVault DL Backup to Disk Appliance that is being upgraded, insert the Backup Exec 2012 DVD into the PowerVault DL Backup to Disk Appliance 2. The DVD will autorun and prompt for a language selection to continue. Select the desired language and press Ok to continue. 3. The Backup Exec 2012 DVD Browser appears.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Figure: Backup Exec 2012 DVD Browser 4. Select Install Products and the Product Installation screen appears.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Figure: Product Installation Screen 5. Select Backup Exec and the Backup Exec 2012 Installation wizard appears. Select Next to continue. 6. Read the Backup Exec 2012 End User License Agreement and select “I agree to the terms of the license agreement”. Select Next to continue. 7. Since this is a local installation, Select Local Install and Install Backup Exec software options. Select Next to continue. 8. The Backup Exec Environment Check will run to check the installation pre-requisites. Correct any items marked with a Red X. Once all items have been checked, select Next to continue. 9. An Environment Check will be performed, once it has completed, select Next to continue. 10. The Backup Exec licensing screen appears. Locate your Backup Exec 2012 version upgrade notification and license files and enter them. This can be done by importing the Symantec License File (SLF), or by entering the Serial Numbers for the licenses. Entering a Serial Number requires an internet connection to verify the serial numbers. See http://www.symantec.com/docs/TECH178483 for more information. Select Next to continue.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Figure: Backup Exec Licensing Screen 11. The Backup Exec Configuration Options appears. Verify that each option that you have entered a license file for will be installed. IMPORTANT : Verify that the Storage Provisioning Option is selected for install. Then select Next to continue.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Figure: Backup Exec Configure Options 12. Specify the service account and credentials for Backup Exec 2012 to use. This should be the same service account specified for Backup Exec 12.5 or Backup Exec 2010. Select Next to continue. 13. Specify the location for the Backup Exec installation. It is recommended that you keep the default location. Select Next to continue. 14. As part of the install, BackupExec 2012 will make a backup copy of the BackupExec 2010 settings found on the system. Specify the location to store the backup settings. It is recommended that you keep the default location. Select Next to continue. 15. Review the Backup Exec Installation Summary to verify your selections. Make sure to carefully review any Warnings.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Figure: Backup Exec Installation Summary Upgrade Information Message 16. Select Install to continue and start the migration process. Once the Data Migration process completes review the report.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Figure: Backup Exec Configure Options 17. Click Continue to proceed with the upgrade 18. The Backup Exec Installation Progress appears. The upgrade process will take approximately 15 to 30 minutes.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance Figure: Backup Exec Installation Progress 19. When the upgrade completes, an upgrade summary appears. Review the upgrade summary and select Next to continue.Upgrading to BackupExec 2012 PowerVault DL Backup to Disk Appliance 20. Review the final installation screen. Select Finish to complete the upgrade and REBOOT the server. 21. The upgrade process is complete. FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\New Cover_Dell_Contax.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 – F O R P R O O F O N LY Template Last Updated -03/06/2010 Dell PowerConnect 5500 Series CLI Reference Guide Regulatory Model: PC5524, PC5524P, PC5548 and PC5548PFILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\New DELL CONFIDENTIAL – PRELIMINARY 9/12/12 – FOR PROOF ONLY Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WARNING: A WARNING indicates a potential for property damage, personal injury, or death. COMMENT Remove paragraph if it does not apply to your publication. ____________________ Information in this publication is subject to change without notice. © 2011-2012 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden. Trademarks used in this text: Dell™, the DELL logo, Dell Precision™, OptiPlex™, Latitude™, PowerEdge™, PowerVault™, PowerConnect™, OpenManage™, EqualLogic™, KACE™, FlexAddress™ and Vostro™ are trademarks of Dell Inc. Intel ® , Pentium ® , Xeon ® , Core™ and Celeron ® are registered trademarks of Intel Corporation in the U.S. and other countries. AMD ® is a registered trademark and AMD Opteron™, AMD Phenom™, and AMD Sempron™ are trademarks of Advanced Micro Devices, Inc. Microsoft ® , Windows ® , Windows Server ® , MS-DOS ® and Windows Vista ® are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries. Red Hat Enterprise Linux ® and Enterprise Linux ® are registered trademarks of Red Hat, Inc. in the United States and/or other countries. Novell ® is a registered trademark and SUSE ™ is a trademark of Novell Inc. in the United States and other countries. Oracle ® is a registered trademark of Oracle Corporation and/or its affiliates. Citrix ® , Xen ® , XenServer ® and XenMotion ® are either registered trademarks or trademarks of Citrix Systems, Inc. in the United States and/or other countries. VMware ® , Virtual SMP ® , vMotion ® , vCenter ® , and vSphere ® are registered trademarks or trademarks of VMWare, Inc. in the United States or other countries. Other trademarks and trade names may be used in this publication to refer to either the entities claiming the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own. Regulatory Models: PC5524, PC5524P, PC5548 and PC5548P September 2012 Rev. A043 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY Contents 1 Preface.................................................................... 33 2 User Interface Commands . . . . . . . . . . . . 41 enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 login. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 configure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 exit (Configuration). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 exit (EXEC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 end . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 history size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 terminal history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 terminal history size. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 terminal datadump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 debug-mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 show history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 show privilege. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 do . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 banner exec . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY banner login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55 banner motd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 exec-banner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 login-banner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 motd-banner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 show banner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 3 Macro Commands . . . . . . . . . . . . . . . . . . 63 macro name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 macro apply. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 macro description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 macro global . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 macro global description . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 show parser macro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 4 System Management Commands . . . . . . 71 ping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 traceroute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 telnet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 resume . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 hostname . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 reload . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 stack master . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 system light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 switch renumber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 show switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 855 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY service cpu-utilization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 show cpu utilization. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 clear cpu counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87 service cpu-counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 show cpu counters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 show users. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 show sessions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 show system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 show version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 system resources routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 show system resources routings. . . . . . . . . . . . . . . . . . . . . . 95 show system tcam utilization. . . . . . . . . . . . . . . . . . . . . . . . . 96 show system defaults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97 show tech-support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 system fans always-on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102 show system fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 asset-tag. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 show system id . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104 5 Clock Commands . . . . . . . . . . . . . . . . . . 107 clock set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 clock source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 clock timezone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108 clock summer-time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109 sntp authentication-key. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 sntp authenticate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1126 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY sntp trusted-key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 sntp client poll timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114 sntp broadcast client enable . . . . . . . . . . . . . . . . . . . . . . . . 115 sntp anycast client enable . . . . . . . . . . . . . . . . . . . . . . . . . . 115 sntp client enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 116 sntp client enable (Interface) . . . . . . . . . . . . . . . . . . . . . . . 117 sntp unicast client enable . . . . . . . . . . . . . . . . . . . . . . . . . . 118 sntp unicast client poll . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 sntp server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 sntp port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121 show clock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122 show sntp configuration. . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 show sntp status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124 6 Configuration/Image File Commands . . 127 copy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127 write memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 delete . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 pwd . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 dir . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 more . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135 cd. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136 rename . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 boot system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 138 show running-config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139 show startup-config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1407 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY show bootvar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140 7 Auto-Update and Auto-Configuration . . 143 boot host auto-config . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 boot host auto-update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143 boot host dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 boot host auto-save . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 show boot. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 ip dhcp tftp-server ip addr. . . . . . . . . . . . . . . . . . . . . . . . . . . 148 ip dhcp tftp-server file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 show ip dhcp tftp-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 8 Management ACL Commands . . . . . . . . . 151 management access-list . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 permit (Management). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152 deny (Management) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 management access-class . . . . . . . . . . . . . . . . . . . . . . . . . . 155 show management access-list . . . . . . . . . . . . . . . . . . . . . . 155 show management access-class . . . . . . . . . . . . . . . . . . . . 156 9 SNMP Commands . . . . . . . . . . . . . . . . . . 159 snmp-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 snmp-server community . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159 snmp-server view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 162 snmp-server group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1638 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY snmp-server user . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165 snmp-server filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 snmp-server host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168 snmp-server engineID local. . . . . . . . . . . . . . . . . . . . . . . . . 171 snmp-server engineID remote . . . . . . . . . . . . . . . . . . . . . . 172 snmp-server enable traps. . . . . . . . . . . . . . . . . . . . . . . . . . . 173 snmp-server trap authentication. . . . . . . . . . . . . . . . . . . . . 174 snmp-server contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174 snmp-server location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 snmp-server set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 show snmp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 176 show snmp engineID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 show snmp views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 show snmp groups. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 show snmp filters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 180 show snmp users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 10 RSA and Certificate Commands . . . . . . 183 crypto key generate dsa . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183 crypto key generate rsa . . . . . . . . . . . . . . . . . . . . . . . . . . . . 184 show crypto key mypubkey . . . . . . . . . . . . . . . . . . . . . . . . . 184 crypto certificate generate . . . . . . . . . . . . . . . . . . . . . . . . . 185 crypto certificate request. . . . . . . . . . . . . . . . . . . . . . . . . . . 187 crypto certificate import. . . . . . . . . . . . . . . . . . . . . . . . . . . . 188 crypto certificate export pkcs12 . . . . . . . . . . . . . . . . . . . . . 190 crypto certificate import pkcs12 . . . . . . . . . . . . . . . . . . . . . 1919 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY show crypto certificate mycertificate . . . . . . . . . . . . . . . . 193 11 Web Server Commands . . . . . . . . . . . . . 195 ip http server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 ip http port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 ip http timeout-policy . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 196 ip http secure-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 197 ip http secure-port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198 ip https certificate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 show ip http . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 show ip https . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 12 Telnet, SSH and Slogin Commands . . . . 203 ip telnet server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 ip ssh port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 ip ssh server. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 204 ip ssh pubkey-auth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 205 crypto key pubkey-chain ssh . . . . . . . . . . . . . . . . . . . . . . . . 206 user-key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 key-string . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 208 show ip ssh . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210 show crypto key pubkey-chain ssh. . . . . . . . . . . . . . . . . . . 211 13 Line Commands . . . . . . . . . . . . . . . . . . . . 213 line. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21310 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 autobaud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 214 exec-timeout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 show line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 14 AAA Commands . . . . . . . . . . . . . . . . . . . 219 aaa authentication login. . . . . . . . . . . . . . . . . . . . . . . . . . . . 219 aaa authentication enable . . . . . . . . . . . . . . . . . . . . . . . . . . 221 login authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 enable authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 ip http authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 show authentication methods. . . . . . . . . . . . . . . . . . . . . . . 225 password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 service password-recovery . . . . . . . . . . . . . . . . . . . . . . . . . 227 enable password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 228 username . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 show user accounts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 aaa accounting login . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 aaa accounting dot1x . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 show accounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 passwords min-length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 passwords strength-check enable. . . . . . . . . . . . . . . . . . . 236 passwords strength minimum character-classes . . . . . . 237 passwords strength max-limit repeated-characters . . . 238 passwords aging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239 passwords history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24011 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY passwords history hold-time . . . . . . . . . . . . . . . . . . . . . . . . 241 passwords lockout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 aaa login-history file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 set username active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 set line active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 set enable-password active . . . . . . . . . . . . . . . . . . . . . . . . . 245 show passwords configuration . . . . . . . . . . . . . . . . . . . . . . 246 show users login-history. . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 15 RADIUS Commands . . . . . . . . . . . . . . . . . 249 radius-server host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249 radius-server key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 radius-server retransmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252 radius-server source-ip. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253 radius-server source-ipv6. . . . . . . . . . . . . . . . . . . . . . . . . . . 254 radius-server timeout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 radius-server deadtime . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 show radius-servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256 16 TACACS+ Commands . . . . . . . . . . . . . . . 259 tacacs-server host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 tacacs-server key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260 tacacs-server timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 tacacs-server source-ip . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 show tacacs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26312 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY 17 Syslog Commands . . . . . . . . . . . . . . . . . 265 logging on . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 265 Logging host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266 logging console . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 logging buffered . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 clear logging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269 logging file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 clear logging file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 aaa logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 271 file-system logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 management logging. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 show logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273 show logging file . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 show syslog-servers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 276 18 RMON Commands . . . . . . . . . . . . . . . . . 277 show rmon statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277 rmon collection stats . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279 show rmon collection stats . . . . . . . . . . . . . . . . . . . . . . . . . 280 show rmon history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281 rmon alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284 show rmon alarm-table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286 show rmon alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287 rmon event. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289 show rmon events . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 show rmon log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29113 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY rmon table-size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 19 802.1x Commands . . . . . . . . . . . . . . . . . . 295 aaa authentication dot1x. . . . . . . . . . . . . . . . . . . . . . . . . . . . 295 dot1x system-auth-control . . . . . . . . . . . . . . . . . . . . . . . . . . 296 dot1x port-control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296 dot1x re-authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . . 298 dot1x timeout reauth-period . . . . . . . . . . . . . . . . . . . . . . . . 298 dot1x re-authenticate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 dot1x timeout quiet-period . . . . . . . . . . . . . . . . . . . . . . . . . . 300 dot1x timeout tx-period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301 dot1x max-req . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302 dot1x timeout supp-timeout . . . . . . . . . . . . . . . . . . . . . . . . . 303 dot1x timeout server-timeout . . . . . . . . . . . . . . . . . . . . . . . . 304 show dot1x. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305 show dot1x users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308 show dot1x statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 clear dot1x statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311 dot1x auth-not-req . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312 dot1x host-mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 dot1x violation-mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314 dot1x guest-vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 315 dot1x guest-vlan timeout. . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 dot1x guest-vlan enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 dot1x mac-authentication . . . . . . . . . . . . . . . . . . . . . . . . . . . 318 dot1x traps mac-authentication success. . . . . . . . . . . . . . 31914 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY dot1x traps mac-authentication failure. . . . . . . . . . . . . . . 319 dot1x radius-attributes vlan. . . . . . . . . . . . . . . . . . . . . . . . . 320 dot1x radius-attributes filter-id. . . . . . . . . . . . . . . . . . . . . . 321 dot1x radius-attributes errors . . . . . . . . . . . . . . . . . . . . . . . 322 dot1x legacy-supp-mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 322 show dot1x advanced . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 323 dot1x system-auth-control monitor . . . . . . . . . . . . . . . . . . 324 show dot1x monitoring result . . . . . . . . . . . . . . . . . . . . . . . 325 20 Ethernet Configuration Commands . . . . 329 interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 interface range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 329 description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330 speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 330 duplex. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 331 negotiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 332 flowcontrol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 333 flowcontrol (Global) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 334 show flowcontrol. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 335 mdix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 336 back-pressure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337 port jumbo-frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 337 clear counters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 338 set interface active . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 339 show interfaces configuration . . . . . . . . . . . . . . . . . . . . . . 339 show interfaces status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34015 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY show interfaces advertise . . . . . . . . . . . . . . . . . . . . . . . . . . 341 show interfaces description. . . . . . . . . . . . . . . . . . . . . . . . . 342 show interfaces counters . . . . . . . . . . . . . . . . . . . . . . . . . . . 343 show port jumbo-frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 346 show errdisable interfaces. . . . . . . . . . . . . . . . . . . . . . . . . . 346 storm-control broadcast enable . . . . . . . . . . . . . . . . . . . . . 347 storm-control broadcast level kbps . . . . . . . . . . . . . . . . . . 348 storm-control include-multicast . . . . . . . . . . . . . . . . . . . . . 349 show storm-control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350 21 PHY Diagnostics Commands. . . . . . . . . . 351 test cable-diagnostics tdr . . . . . . . . . . . . . . . . . . . . . . . . . . . 351 show cable-diagnostics tdr . . . . . . . . . . . . . . . . . . . . . . . . . 352 show cable-diagnostics cable-length . . . . . . . . . . . . . . . . 353 show fiber-ports optical-transceiver . . . . . . . . . . . . . . . . . 353 22 Power over Ethernet (PoE) Commands . 357 power inline. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 357 power inline limit-mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 358 power inline powered-device . . . . . . . . . . . . . . . . . . . . . . . 359 power inline priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 359 power inline usage-threshold . . . . . . . . . . . . . . . . . . . . . . . 360 power inline traps enable. . . . . . . . . . . . . . . . . . . . . . . . . . . 361 power inline limit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 361 show power inline . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 362 show power inline consumption . . . . . . . . . . . . . . . . . . . . . 36616 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY show power inline version . . . . . . . . . . . . . . . . . . . . . . . . . 367 23 EEE Commands . . . . . . . . . . . . . . . . . . . 369 eee enable (global) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369 eee enable (interface). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369 eee lldp enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370 show eee . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 370 24 Green Ethernet . . . . . . . . . . . . . . . . . . . 377 show green-ethernet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 377 green-ethernet short-reach (global). . . . . . . . . . . . . . . . . . 379 green-ethernet short-reach (interface) . . . . . . . . . . . . . . . 379 green-ethernet short-reach force . . . . . . . . . . . . . . . . . . . . 380 green-ethernet short-reach threshold . . . . . . . . . . . . . . . . 381 green-ethernet power-meter reset. . . . . . . . . . . . . . . . . . . 382 25 Port Channel Commands . . . . . . . . . . . . 383 channel-group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383 port-channel load-balance . . . . . . . . . . . . . . . . . . . . . . . . . 384 show interfaces port-channel . . . . . . . . . . . . . . . . . . . . . . . 385 26 Address Table Commands . . . . . . . . . . . 387 bridge multicast filtering . . . . . . . . . . . . . . . . . . . . . . . . . . . 387 bridge multicast address . . . . . . . . . . . . . . . . . . . . . . . . . . . 388 bridge multicast forbidden address . . . . . . . . . . . . . . . . . . 38917 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY bridge multicast unregistered . . . . . . . . . . . . . . . . . . . . . . . 390 bridge multicast forward-all . . . . . . . . . . . . . . . . . . . . . . . . 391 bridge multicast forbidden forward-all . . . . . . . . . . . . . . . 392 mac address-table static . . . . . . . . . . . . . . . . . . . . . . . . . . . 393 clear mac address-table . . . . . . . . . . . . . . . . . . . . . . . . . . . 394 mac address-table aging-time . . . . . . . . . . . . . . . . . . . . . . 395 port security. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 396 port security mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397 port security max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 397 port security routed secure-address. . . . . . . . . . . . . . . . . . 398 show mac address-table . . . . . . . . . . . . . . . . . . . . . . . . . . . 399 show mac address-table count . . . . . . . . . . . . . . . . . . . . . . 401 show bridge multicast address-table. . . . . . . . . . . . . . . . . 401 show bridge multicast address-table static . . . . . . . . . . . 405 show bridge multicast filtering . . . . . . . . . . . . . . . . . . . . . . 408 show bridge multicast unregistered. . . . . . . . . . . . . . . . . . 409 show ports security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 410 show ports security addresses . . . . . . . . . . . . . . . . . . . . . . 411 27 Port Monitor Commands . . . . . . . . . . . . . 413 port monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413 show ports monitor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415 28 sFlow Commands . . . . . . . . . . . . . . . . . . 417 sflow receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417 sflow flow-sampling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41818 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY sflow counters-sampling . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 clear sflow statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419 show sflow configuration . . . . . . . . . . . . . . . . . . . . . . . . . . 420 show sflow statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 421 29 LLDP Commands . . . . . . . . . . . . . . . . . . 423 lldp run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423 lldp transmit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 423 lldp receive . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424 lldp timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 425 lldp hold-multiplier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 426 lldp reinit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 427 lldp tx-delay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428 lldp optional-tlv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 428 lldp management-address . . . . . . . . . . . . . . . . . . . . . . . . . . 429 lldp notifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 430 lldp notifications interval . . . . . . . . . . . . . . . . . . . . . . . . . . . 431 lldp optional-tlv 802.1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432 lldp med enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 433 lldp med notifications topology-change . . . . . . . . . . . . . . 434 lldp med fast-start repeat-count . . . . . . . . . . . . . . . . . . . . . 435 lldp med network-policy (global) . . . . . . . . . . . . . . . . . . . . 435 lldp med network-policy (interface) . . . . . . . . . . . . . . . . . 436 clear lldp table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437 lldp med location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 438 show lldp configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43919 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY show lldp med configuration . . . . . . . . . . . . . . . . . . . . . . . . 441 show lldp local tlvs-overloading. . . . . . . . . . . . . . . . . . . . . 443 show lldp local . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 444 show lldp neighbors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 446 show lldp statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 451 30 Spanning-Tree Commands . . . . . . . . . . . 453 spanning-tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 453 spanning-tree mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 453 spanning-tree forward-time . . . . . . . . . . . . . . . . . . . . . . . . . 454 spanning-tree hello-time. . . . . . . . . . . . . . . . . . . . . . . . . . . . 455 spanning-tree max-age . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 456 spanning-tree priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 457 spanning-tree disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 458 spanning-tree cost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 459 spanning-tree port-priority . . . . . . . . . . . . . . . . . . . . . . . . . . 460 spanning-tree portfast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 460 spanning-tree link-type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 461 spanning-tree pathcost method . . . . . . . . . . . . . . . . . . . . . . 462 spanning-tree bpdu (Global). . . . . . . . . . . . . . . . . . . . . . . . . 463 spanning-tree bpdu (Interface) . . . . . . . . . . . . . . . . . . . . . . 464 spanning-tree guard root. . . . . . . . . . . . . . . . . . . . . . . . . . . . 465 spanning-tree bpduguard . . . . . . . . . . . . . . . . . . . . . . . . . . . 466 clear spanning-tree detected-protocols . . . . . . . . . . . . . . 467 spanning-tree mst priority. . . . . . . . . . . . . . . . . . . . . . . . . . . 467 spanning-tree mst max-hops . . . . . . . . . . . . . . . . . . . . . . . . 46820 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY spanning-tree mst port-priority . . . . . . . . . . . . . . . . . . . . . . 469 spanning-tree mst cost . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 470 spanning-tree mst configuration. . . . . . . . . . . . . . . . . . . . . 471 instance (MST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 472 name (MST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473 revision (MST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 473 show (MST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 474 exit (MST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 475 abort (MST) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 476 show spanning-tree. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 476 show spanning-tree bpdu. . . . . . . . . . . . . . . . . . . . . . . . . . . 491 31 VLAN Commands . . . . . . . . . . . . . . . . . . 493 vlan database . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493 vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 493 interface vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 494 interface range vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 495 name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 496 switchport protected-port . . . . . . . . . . . . . . . . . . . . . . . . . . 497 switchport community . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 498 show interfaces protected-ports . . . . . . . . . . . . . . . . . . . . 498 switchport . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 499 switchport mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500 switchport access vlan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501 switchport access multicast-tv vlan . . . . . . . . . . . . . . . . . 502 switchport trunk allowed vlan . . . . . . . . . . . . . . . . . . . . . . 50321 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY switchport trunk native vlan. . . . . . . . . . . . . . . . . . . . . . . . . 504 switchport general allowed vlan . . . . . . . . . . . . . . . . . . . . 505 switchport general pvid . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506 switchport general ingress-filtering disable . . . . . . . . . . 507 switchport general acceptable-frame-type . . . . . . . . . . . 508 switchport customer vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . 509 switchport general forbidden vlan . . . . . . . . . . . . . . . . . . . 509 map protocol protocols-group . . . . . . . . . . . . . . . . . . . . . . . 510 switchport general map protocols-group vlan . . . . . . . . . 511 private-vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 512 private-vlan association . . . . . . . . . . . . . . . . . . . . . . . . . . . . 513 switchport private-vlan mapping . . . . . . . . . . . . . . . . . . . . 514 switchport private-vlan host-association . . . . . . . . . . . . . 515 show vlan private-vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516 ip internal-usage-vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 516 show vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 518 show vlan multicast-tv . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 519 show vlan protocols-groups. . . . . . . . . . . . . . . . . . . . . . . . . 519 show vlan internal usage . . . . . . . . . . . . . . . . . . . . . . . . . . . 520 show interfaces switchport . . . . . . . . . . . . . . . . . . . . . . . . . 521 32 IGMP Snooping Commands . . . . . . . . . . 523 ip igmp snooping (Global) . . . . . . . . . . . . . . . . . . . . . . . . . . . 523 ip igmp snooping vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 523 ip igmp snooping mrouter . . . . . . . . . . . . . . . . . . . . . . . . . . 524 ip igmp snooping mrouter interface . . . . . . . . . . . . . . . . . . 52522 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY ip igmp snooping forbidden mrouter interface . . . . . . . . 526 ip igmp snooping static . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527 ip igmp snooping multicast-tv . . . . . . . . . . . . . . . . . . . . . . . 528 ip igmp snooping querier . . . . . . . . . . . . . . . . . . . . . . . . . . . 529 ip igmp snooping querier address . . . . . . . . . . . . . . . . . . . 530 ip igmp robustness. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 531 ip igmp query-interval. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 531 ip igmp query-max-response-time . . . . . . . . . . . . . . . . . . . 532 ip igmp last-member-query-count . . . . . . . . . . . . . . . . . . . 533 ip igmp last-member-query-interval . . . . . . . . . . . . . . . . . 534 ip igmp snooping vlan immediate-leave . . . . . . . . . . . . . . 534 show ip igmp snooping mrouter . . . . . . . . . . . . . . . . . . . . . 535 show ip igmp snooping interface . . . . . . . . . . . . . . . . . . . . 536 show ip igmp snooping groups . . . . . . . . . . . . . . . . . . . . . . 537 show ip igmp snooping multicast-tv . . . . . . . . . . . . . . . . . 538 33 LACP Commands . . . . . . . . . . . . . . . . . . 541 lacp system-priority. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541 lacp port-priority . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542 lacp timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542 show lacp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543 show lacp port-channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 546 34 GVRP Commands . . . . . . . . . . . . . . . . . . 547 gvrp enable (Global) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547 gvrp enable (Interface) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54723 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY garp timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 548 gvrp vlan-creation-forbid . . . . . . . . . . . . . . . . . . . . . . . . . . . 550 gvrp registration-forbid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 550 clear gvrp statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 551 show gvrp configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . 552 show gvrp statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 553 show gvrp error-statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . 554 35 Voice VLAN Commands . . . . . . . . . . . . . 557 voice vlan id. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 557 voice vlan oui-table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 558 voice vlan cos mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 559 voice vlan cos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 560 voice vlan aging-timeout. . . . . . . . . . . . . . . . . . . . . . . . . . . . 561 voice vlan enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 561 voice vlan secure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 562 show voice vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 563 36 DHCP Snooping and ARP Inspection Commands 567 ip dhcp snooping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 567 ip dhcp snooping vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 568 ip dhcp snooping trust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 568 ip dhcp snooping information option allowed-untrusted 569 ip dhcp snooping verify . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 570 ip dhcp snooping database. . . . . . . . . . . . . . . . . . . . . . . . . . 57124 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY ip dhcp snooping database update-freq . . . . . . . . . . . . . . 572 ip dhcp snooping binding . . . . . . . . . . . . . . . . . . . . . . . . . . . 572 clear ip dhcp snooping database . . . . . . . . . . . . . . . . . . . . 574 show ip dhcp snooping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 574 show ip dhcp snooping binding . . . . . . . . . . . . . . . . . . . . . 575 ip arp inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 576 ip arp inspection vlan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 577 ip arp inspection trust . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 578 ip arp inspection validate. . . . . . . . . . . . . . . . . . . . . . . . . . . 579 ip arp inspection list create. . . . . . . . . . . . . . . . . . . . . . . . . 580 ip mac. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 580 ip arp inspection list assign. . . . . . . . . . . . . . . . . . . . . . . . . 581 ip arp inspection logging interval. . . . . . . . . . . . . . . . . . . . 582 show ip arp inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 583 show ip arp inspection list. . . . . . . . . . . . . . . . . . . . . . . . . . 584 show ip arp inspection statistics . . . . . . . . . . . . . . . . . . . . 584 clear ip arp inspection statistics . . . . . . . . . . . . . . . . . . . . 585 ip dhcp information option . . . . . . . . . . . . . . . . . . . . . . . . . . 586 show ip dhcp information option . . . . . . . . . . . . . . . . . . . . 586 37 iSCSI Commands . . . . . . . . . . . . . . . . . . 589 iscsi enable. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 589 iscsi target port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 590 iscsi cos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 591 iscsi aging-time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 593 iscsi max-tcp-connections . . . . . . . . . . . . . . . . . . . . . . . . . 59425 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY show iscsi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 595 show iscsi sessions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 596 38 IP Addressing Commands . . . . . . . . . . . . 599 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 599 ip address dhcp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601 renew dhcp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602 ip default-gateway . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603 show ip interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603 arp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604 arp timeout (Global) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605 arp timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 606 ip arp proxy disable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 607 ip proxy-arp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 607 clear arp-cache. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 608 show arp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 608 show arp configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609 interface ip. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610 directed-broadcast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 611 broadcast-address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 612 ip helper-address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 612 show ip helper-address. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 614 source-precedence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615 ip domain lookup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616 ip domain name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616 ip name-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61726 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY ip host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619 clear host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620 clear host dhcp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620 show hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621 39 IPv6 Addressing Commands . . . . . . . . . 623 ipv6 enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623 ipv6 address autoconfig . . . . . . . . . . . . . . . . . . . . . . . . . . . . 624 ipv6 icmp error-interval . . . . . . . . . . . . . . . . . . . . . . . . . . . . 625 show ipv6 icmp error-interval . . . . . . . . . . . . . . . . . . . . . . . 626 ipv6 address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 627 ipv6 address link-local . . . . . . . . . . . . . . . . . . . . . . . . . . . . 628 ipv6 unreachables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 629 ipv6 default-gateway. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 630 show ipv6 interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 631 show IPv6 route . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 633 ipv6 nd dad attempts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 634 ipv6 host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635 ipv6 neighbor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 636 ipv6 set mtu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637 ipv6 mld version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 638 ipv6 mld join-group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 639 show ipv6 neighbors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 640 clear ipv6 neighbors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64127 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY 40 Tunnel Commands . . . . . . . . . . . . . . . . . . 643 interface tunnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643 tunnel mode ipv6ip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 643 tunnel isatap router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 644 tunnel source . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 645 tunnel isatap query-interval . . . . . . . . . . . . . . . . . . . . . . . . . 646 tunnel isatap solicitation-interval. . . . . . . . . . . . . . . . . . . . 647 tunnel isatap robustness . . . . . . . . . . . . . . . . . . . . . . . . . . . . 648 show ipv6 tunnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 649 41 DHCP Relay Commands . . . . . . . . . . . . . 651 ip dhcp relay enable (Global) . . . . . . . . . . . . . . . . . . . . . . . . 651 ip dhcp relay enable (Interface). . . . . . . . . . . . . . . . . . . . . . 651 ip dhcp relay address (Global) . . . . . . . . . . . . . . . . . . . . . . . 652 ip dhcp relay address (Interface). . . . . . . . . . . . . . . . . . . . . 653 show ip dhcp relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 654 ip dhcp information option . . . . . . . . . . . . . . . . . . . . . . . . . . 655 show ip dhcp information option. . . . . . . . . . . . . . . . . . . . . 656 42 DHCP Server Commands . . . . . . . . . . . . 657 ip dhcp server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657 ip dhcp pool host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 657 ip dhcp pool network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 658 address (DHCP Host) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 659 address (DHCP Network) . . . . . . . . . . . . . . . . . . . . . . . . . . . 66028 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY lease . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 661 client-name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 663 default-router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 663 dns-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 664 domain-name . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 665 netbios-name-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 netbios-node-type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 667 next-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 667 next-server-name. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 668 bootfile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 669 time-server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 670 option . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 671 ip dhcp excluded-address . . . . . . . . . . . . . . . . . . . . . . . . . . 672 ip dhcp ping enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673 ping enable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 674 ip dhcp ping count . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 675 ip dhcp ping timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 676 clear ip dhcp binding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 677 show ip dhcp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 677 show ip dhcp excluded-addresses . . . . . . . . . . . . . . . . . . 678 show ip dhcp pool host. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 678 show ip dhcp pool network . . . . . . . . . . . . . . . . . . . . . . . . . 680 show ip dhcp binding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681 show ip dhcp server statistics . . . . . . . . . . . . . . . . . . . . . . 683 show ip dhcp allocated . . . . . . . . . . . . . . . . . . . . . . . . . . . . 684 show ip dhcp declined . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68629 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY show ip dhcp expired . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 687 show ip dhcp pre-allocated . . . . . . . . . . . . . . . . . . . . . . . . . 688 43 IP Routing Protocol-Independent Commands 691 ip route . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 691 ip routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 692 show ip route. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 692 44 ACL Commands . . . . . . . . . . . . . . . . . . . . 695 ip access-list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 695 permit ( IP ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 696 deny ( IP ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 698 ipv6 access-list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 702 permit ( IPv6 ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 703 deny ( IPv6 ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 705 mac access-list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 708 permit ( MAC ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 709 service-acl input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 710 service-acl output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 711 service-acl input block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 712 time-range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713 absolute . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714 periodic. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715 show time-range. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717 show access-lists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717 show interfaces access-lists . . . . . . . . . . . . . . . . . . . . . . . . 71930 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY clear access-lists counters . . . . . . . . . . . . . . . . . . . . . . . . . 719 show interfaces access-lists counters . . . . . . . . . . . . . . . 720 45 Quality of Service (QoS) Commands . . . 723 qos. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 723 show qos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724 class-map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 725 show class-map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 726 match . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727 policy-map. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 727 class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 729 show policy-map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 730 trust. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731 set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 732 police . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733 service-policy. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 735 qos aggregate-policer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 735 show qos aggregate-policer . . . . . . . . . . . . . . . . . . . . . . . . 737 police aggregate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 737 wrr-queue cos-map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 738 wrr-queue bandwidth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 740 priority-queue out num-of-queues . . . . . . . . . . . . . . . . . . . 741 traffic-shape . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 742 traffic-shape queue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 743 rate-limit (Ethernet) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 744 qos wrr-queue wrtd. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74431 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY show qos interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 745 qos wrr-queue threshold . . . . . . . . . . . . . . . . . . . . . . . . . . . . 748 qos map policed-dscp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 749 qos map dscp-queue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 750 qos map dscp-dp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 751 qos trust (Global). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 752 qos trust (Interface) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 753 qos cos . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 754 qos dscp-mutation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 755 qos map dscp-mutation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756 show qos map . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 757 clear qos statistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759 qos statistics policer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 759 qos statistics aggregate-policer . . . . . . . . . . . . . . . . . . . . . 760 qos statistics queues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 760 show qos statistics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76132 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Dell_ContaxTOC.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 2 0 1 2 - F O R P R O O F O N LY33 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Preface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 1 Preface About this Document This CLI Reference Guide describes how to use the CLI and a list of the CLI commands and their arguments. The CLI commands described in this document are organized according to feature groups in separate sections. This section describes how to use the CLI. It contains the following topics: • CLI Command Modes • Starting the CLI • CLI Command Conventions • Entering Commands CLI Command Modes To configure devices, the CLI is divided into various command modes. Each command mode has its own set of specific commands. Entering a question mark "?" at the console prompt displays a list of commands available for that particular command mode. A specific command, which varies from mode to mode, is used to navigate from one mode to another. The standard order to access the modes is as follows: User EXEC mode, Privileged EXEC mode, Global Configuration mode, and Interface Configuration modes. When starting a session, the initial mode for non-privileged users is the User EXEC mode. Only a limited subset of commands is available in the User EXEC mode. This level is reserved for tasks that do not change the configuration. 34 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Preface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Privileged users enter the Privileged EXEC mode directly using a password. This mode provides access to the device Configuration modes. The modes are described below. User EXEC Mode After logging into the device, the user is automatically in User EXEC command mode unless the user is defined as a privileged user. In general, the User EXEC commands enable the user to perform basic tests, and display system information. The user-level prompt consists of the device "host name" followed by the angle bracket (>). console> The default host name is "console" unless it has been changed using the hostname command in the Global Configuration mode. Privileged EXEC Mode Privileged access is password-protected to prevent unauthorized use, because many of the privileged commands set operating system parameters: The password is not displayed on the screen and is case sensitive. Privileged users enter directly into the Privileged EXEC mode. Use disable to return to the User EXEC mode. Global Configuration Mode Global Configuration mode commands apply to features that affect the system as a whole, rather than just a specific interface. To enter the Global Configuration mode, enter configure in the Privileged EXEC mode, and press . The Global Configuration mode prompt is displayed. console(config)# Use exit, end or ctrl/z to return to the Privileged EXEC mode. Interface Configuration Modes Commands in the following modes perform specific interface operations:35 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Preface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • Line Interface — Contains commands to configure the management connections. These include commands such as line speed, timeout settings, etc. The Global Configuration mode command line is used to enter the Line Configuration command mode. • VLAN Database — Contains commands to create a VLAN as a whole. The Global Configuration mode command vlan database is used to enter the VLAN Database Interface Configuration mode. • Management Access List — Contains commands to define management access-lists. The Global Configuration mode command management access-list is used to enter the Management Access List Configuration mode. • Port Channel — Contains commands to configure port-channels, for example, assigning ports to a VLAN or port-channel. The Global Configuration mode command interface port-channel is used to enter the Port Channel Interface Configuration mode. • SSH Public Key-Chain — Contains commands to manually specify other device SSH public keys. The Global Configuration mode command crypto key pubkey-chain ssh is used to enter the SSH Public Key-chain Configuration mode. • Interface — Contains commands that configure the interface. The Global Configuration mode command interface is used to enter the Interface Configuration mode. Starting the CLI The switch can be managed over a direct connection to the switch console port, or via a Telnet connection. The switch is managed by entering command keywords and parameters at the prompt. Using the switch CLI commands is similar to entering commands on a UNIX system. If access is via a Telnet connection, ensure the device has an IP address defined, corresponding management access is granted, and the workstation used to access the device is connected to the device prior to using CLI commands. Accessing the CLI from the Console Line 1. Start the device and wait until the startup procedure is complete. The User Exec mode is entered, and the prompt "console>" is displayed. 36 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Preface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY 2. Configure the device and enter the necessary commands to complete the required tasks. 3. When finished, exit the session with the quit or exit command. Accessing the CLI from Telnet 1. Enter telnet and the IP address of the device. A User Name prompt is displayed. 2. Enter the User Name and Password. You are in the Privileged Exec mode. 3. Configure the device and enter the necessary commands to complete the required tasks. 4. When finished, exit the session with the quit or exit command. When another user is required to log onto the system, the login command is entered in the Privileged EXEC command mode,. This effectively logs off the current user and logs on the new user. CLI Command Conventions The following table describes the command syntax conventions. Conventions Description [ ] In a command line, square brackets indicates an optional entry. { } In a command line, curly brackets indicate a selection of compulsory parameters separated by the | character. One option must be selected. For example: flowcontrol {auto|on|off} means that for the flowcontrol command either auto, on or off must be selected. Italic font Indicates a parameter. Any individual key on the keyboard. For example click . Ctrl+F4 Any combination keys pressed simultaneously on the keyboard.37 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Preface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Entering Commands A CLI command is a series of keywords and arguments. Keywords identify a command, and arguments specify configuration parameters. For example, in the command "show interfaces status gi1/0/5" show, interfaces and status are keywords, gi is an argument that specifies the interface type, and 1/0/5 is an argument that specifies the port. To enter commands that require parameters, enter the required parameters after the command keyword. For example, to set a password for the administrator, enter: console(config)# username admin password smith Help information can be displayed in the following ways: • Keyword Lookup — The character ? is entered in place of a command. A list of all valid commands and corresponding help messages are displayed. • Partial Keyword Lookup — A command is incomplete and the character ? is entered in place of a parameter. The matched parameters for this command are displayed. The following describes features that assist in using the CLI: Terminal Command Buffer Every time a command is entered in the CLI, it is recorded on an internally managed Command History buffer. Commands stored in the buffer are maintained on a First In First Out (FIFO) basis.These commands can be Screen Display Indicates system messages and prompts appearing on the console. all When a parameter is required to define a range of ports or parameters and all is an option, the default for the command is all when no parameters are defined. For example, the command interface range port-channel has the option of either entering a range of channels, or selecting all. When the command is entered without a parameter, it automatically defaults to all. Conventions Description38 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Preface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY recalled, reviewed, modified, and reissued. This buffer is not preserved across device resets. The keys that can be used to access the history buffer are described in Table 1. By default, the history buffer system is enabled, but it can be disabled at any time. For information about the command syntax to enable or disable the history buffer, see the history command. There is a standard default number of commands that are stored in the buffer. The standard number of 10 commands can be increased to 256. By configuring 0, the effect is the same as disabling the history buffer system. For information about the command syntax for configuring the command history buffer, see the history size command. To display the history buffer, see show history command. Negating the Effect of Commands For many configuration commands, the prefix keyword "no" can be entered to cancel the effect of a command or reset the configuration to the default value. This guide describes the negation effect for all applicable commands. Command Completion If the command entered is incomplete, invalid, or has missing or invalid parameters, an appropriate error message is displayed. To complete an incomplete command, press the button. If the characters already entered are not enough for the system to identify a single matching command, press "?" to display the available commands matching the characters already entered. Incorrect or incomplete commands are automatically re-entered next to the cursor. If a parameter must be added, the parameter can be added to the basic command already displayed next to the cursor. The following example indicates that the command interface requires a missing parameter. (config)#interface %missing mandatory parameter (config)#interface39 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Preface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Keyboard Shortcuts The CLI has a range of keyboard shortcuts to assist in entering the CLI commands. The following table describes these shortcuts: Table 1: Keyboard Keys Keyboard Key Description Up-arrow key Recalls commands from the history buffer, beginning with the most recent command. Repeat the key sequence to recall successively older commands. Down-arrow key Returns the most recent commands from the history buffer after recalling commands with the up arrow key. Repeating the key sequence will recall successively more recent commands. Ctrl+A Moves the cursor to the beginning of the command line. Ctrl+E Moves the cursor to the end of the command line. Ctrl+Z / End Returns back to the Privileged EXEC mode from any mode. Backspace key Moves the cursor back one space. Up-arrow key Recalls commands from the history buffer, beginning with the most recent command. Repeat the key sequence to recall successively older commands.40 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\CLI_Preface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYUser Interface Commands 41 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 2 User Interface Commands enable The enable EXEC mode command enters the Privileged EXEC mode. Syntax enable [privilege-level] Parameters privilege-level—Specifies the privilege level at which to enter the system. (Range: 1–15) Default Configuration The default privilege level is 15. Command Mode EXEC mode Example The following example enters the Privileged EXEC mode. Console> enable enter password: Console#42 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY disable The disable Privileged EXEC mode command leaves the Privileged EXEC mode and returns to the User EXEC mode. Syntax disable [privilege-level] Parameters privilege-level—Specifies the privilege level at which to enter the system. (Range: 1–15) Default Configuration The default privilege level is 1. Command Mode Privileged EXEC mode Example The following example returns to the User EXEC mode. Console# disable Console> login The login EXEC mode command changes a user’s login. Syntax login Command Mode EXEC modeUser Interface Commands 43 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enters Privileged EXEC mode and logs in with username ‘admin’. Console> login User Name:admin Password:***** Console# configure The configure Privileged EXEC mode command enters the Global Configuration mode. Syntax configure [terminal] Parameters terminal—Enter the Global Configuration mode with or without the keyword terminal. Command Mode Privileged EXEC mode Example The following example enters Global Configuration mode. Console# configure Console(config)# exit (Configuration) The exit command exits any configuration mode to the next highest mode in the CLI mode hierarchy.44 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax exit Command Mode All commands in configuration modes. Examples The following examples change the configuration mode from Interface Configuration mode to Privileged EXEC mode. Console(config-if)# exit Console(config)# exit Console# Router(config-if)# exit Router(config)# exit Router# exit (EXEC) The exit EXEC mode command closes an active terminal session by logging off the device. Syntax exit Command Mode EXEC mode Example The following examples close an active terminal session. Console> exit Router> exitUser Interface Commands 45 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY end The end command ends the current configuration session and returns to the Privileged EXEC mode. Syntax end Command Mode All configuration modes Example The following examples end the Global Configuration mode session and return to the Privileged EXEC mode. Console(config)# end Console# Router(config-if)# end Router# help The help command displays a brief description of the Help system. Syntax help Command Mode All command modes Example The following example describes the Help system. Console# help46 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Help may be requested at any point in a command by entering a question mark '?'. If nothing matches the currently entered incomplete command, the help list is empty. This indicates that there is no command matching the input as it currently appears. If the request is within a command, press the Backspace key and erase the entered characters to a point where the request results in a match. Help is provided when: 1. There is a valid command and a help request is made for entering a parameter or argument (e.g. 'show ?'). All possible parameters or arguments for the entered command are then displayed. 2. An abbreviated argument is entered and a help request is made for arguments matching the input (e.g. 'show pr?'). history The history Line Configuration mode command enables the command history function. Use the no form of this command to disable the command history function. Syntax history no history Default Configuration The history command is enabled. Command Mode Line Configuration mode User Guidelines This command enables the command history function for a specified line. Use the terminal history EXEC mode command to enable or disable the command history function for the current terminal session.User Interface Commands 47 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables the command history function for Telnet. Console(config)# line telnet Console(config-line)# history history size The history size Line Configuration mode command changes the command history buffer size for a particular line. Use the no form of this command to reset the command history buffer size to the default value. Syntax history size number-of-commands no history size Parameters number-of-commands—Specifies the number of commands the system records in its history buffer. (Range: 0–256) Default Configuration The default command history buffer size is 10 commands. Command Mode Line Configuration mode User Guidelines This command configures the command history buffer size for a particular line. Use the terminal history size EXEC mode command to configure the command history buffer size for the current terminal session. The allocated command history buffer is per terminal user, and is taken from a shared buffer. If there is not enough space available in the shared buffer, the command history buffer size () cannot be increased above the default size.48 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example changes the command history buffer size to 100 entries for a particular line Console(config)# line telnet Console(config-line)# history size 100 terminal history The terminal history EXEC mode command enables the command history function for the current terminal session. Use the no form of this command to disable the command history function. Syntax terminal history terminal no history Default Configuration The default configuration for all terminal sessions is defined by the history Line Configuration mode command. Command Mode EXEC mode User Guidelines The command enables the command history for the current session. The default is determined by the history Line Configuration mode command. Example The following example disables the command history function for the current terminal session. Console> terminal no historyUser Interface Commands 49 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY terminal history size The terminal history size EXEC mode command changes the command history buffer size for the current terminal session. Use the no form of this command to reset the command history buffer size to the default value. Syntax terminal history size number-of-commands terminal no history size Parameters number-of-commands—Specifies the number of commands the system maintains in its history buffer. (Range: 10–256) Default Configuration The default configuration for all terminal sessions is defined by the history size Line Configuration mode command. Command Mode EXEC mode User Guidelines The terminal history size EXEC command changes the command history buffer size for the current terminal session. Use the history Line Configuration mode command to change the default command history buffer size. The maximum number of commands in all buffers is 256. Example The following example sets the command history buffer size to 20 commands for the current terminal session. Console> terminal history size 2050 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY terminal datadump The terminal datadump EXEC mode command enables dumping all the output of a show command without prompting. Use the no form of this command to disable dumping. Syntax terminal datadump terminal no datadump Default Configuration Dumping is disabled. Command Mode EXEC mode User Guidelines By default, a More prompt is displayed when the output contains more lines than can be displayed on the screen. Pressing the Enter key displays the next line; pressing the Spacebar displays the next screen of output. The terminal datadump command enables dumping all output immediately after entering the show command. This command is relevant only for the current session. Example The following example dumps all output immediately after entering a show command. Console> terminal datadump debug-mode The debug-mode Privileged EXEC mode command mode switches to debug mode.User Interface Commands 51 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax debug-mode Command Mode Privileged EXEC mode Example The following example enters Debug mode. Console# debug-mode show history The show history EXEC mode command lists commands entered in the current session. Syntax show history Command Mode EXEC mode User Guidelines The buffer includes executed and unexecuted commands. Commands are listed from the first to the most recent command. The buffer remains unchanged when entering into and returning from configuration modes. Example The following example displays all the commands entered while in the current Privileged EXEC mode. Console# show version SW version 3.131 (date 23-Jul-2005 time 17:34:19) HW version 1.0.0 Console# show clock52 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY 15:29:03 Jun 17 2005 Console# show history show version show clock show history 3 commands were logged (buffer size is 10) show privilege The show privilege EXEC mode command displays the current privilege level. Syntax show privilege Command Mode EXEC mode Example The following example displays the current privilege level for the Privileged EXEC mode. Console# show privilege Current privilege level is 15 do The do command executes an EXEC-level command from Global Configuration mode or any configuration submode. Syntax do command Parameters command—Specifies the EXEC-level command to execute.User Interface Commands 53 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode All configuration modes Example The following example executes the show vlan Privileged EXEC mode command from Global Configuration mode. Example Console (Config)# do show vlan Vlan Name Ports Type Authorization ---- ---- --------------------------- -------- ------------- 1 1 gi1/0/1-39,Po1,Po2, other Required Po3,Po4,Po5,Po6,Po7,Po8 2 2 gi1/0/1 dynamicGvrp Required 10 v0010 gi1/0/1 permanent Not Required 11 V0011 gi1/0/1,gi1/0/13 permanent Required 20 20 gi1/0/1 permanent Required 30 30 gi1/0/1,gi1/0/13 permanent Required 31 31 gi1/0/1 permanent Required 91 91 gi1/0/1,gi1/0/40 permanent Required 4093 guest-vlan gi1/0/1,gi1/0/13 permanent Guest console(config)#s banner exec Use the banner exec command to specify and enable a message to be displayed when an EXEC process is created (The user has successfully logged in), use the banner exec command in Global Configuration mode. Use the no form of this command to delete the existing EXEC banner. Syntax banner exec d message-text d no banner exec54 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • d—Delimiting character of your choice—a pound sign (#), for example. You cannot use the delimiting character in the banner message. • message-text—The message must start in a new line. You can enter multiline messages. You can include tokens in the form of $(token) in the message text. Tokens are replaced with the corresponding configuration variable. Tokens are described in the User Guidelines. The message can contain up to 2000 characters (after every 510 characters, you must press to continue). Default Configuration Disabled (no EXEC banner is displayed). Command Mode Global Configuration mode User Guidelines Follow this command with one or more blank spaces and a delimiting character of your choice. Then enter one or more lines of text, terminating the message with the second occurrence of the delimiting character. When a user connects to a device, the message-of-the-day (MOTD) banner appears first, followed by the login banner and prompts. After the user logs in to the device, the EXEC banner is displayed. Use tokens in the form of $(token) in the message text to customize the banner. The tokens are described in the table below: Token Information displayed in the banner $(hostname) Displays the host name for the device. $(domain) Displays the domain name for the device. $(bold) Indicates that the next text is a bold text. Using this token again indicates the end of the bold text. $(inverse) Indicates that the next text is an inverse text. Using this token again indicates the end of the inverse text. $(contact) Displays the system contact string.User Interface Commands 55 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Use the no exec-banner line configuration command to disable the EXEC banner on a particular line or lines. Example The following example sets an EXEC banner that uses tokens. The percent sign (%) is used as a delimiting character. Note that the $(token) syntax is replaced by the corresponding configuration variable. Device(config)# banner exec % Enter TEXT message. End with the character '%'. $(bold)Session activated.$(bold) Enter commands at the prompt. % When a user logs on to the system, the following output is displayed: Session activated. Enter commands at the prompt. banner login Use the banner login command in Global Configuration mode to specify and enable a message to be displayed before the username and password login prompts. Use the no form of this command to delete the existing Login banner. Syntax banner login d message-text d no banner login Parameters • Delimiting character of your choice—A pound sign (#), for example. You cannot use the delimiting character in the banner message. $(location) Displays the system location string. $(macaddress) Displays the base MAC address of the device.56 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • message-text—Message text. The message must start on a new line. You can enter multi-line messages. You can include tokens in the form of $(token) in the message text. Tokens are replaced with the corresponding configuration variable. Tokens are described in the User Guidelines. The message can contain up to 2000 characters (after every 510 characters, you must press to continue). Default Configuration Disabled (no Login banner is displayed). Command Mode Global Configuration mode User Guidelines Follow this command with one or more blank spaces and a delimiting character of your choice. Then enter one or more lines of text, terminating the message with the second occurrence of the delimiting character. When a user connects to a device, the message-of-the-day (MOTD) banner appears first, followed by the login banner and prompts. After the user logs in to the device, the EXEC banner is displayed. Use tokens in the form of $(token) in the message text to customize the banner. The tokens are described in the table below: Token Information displayed in the banner $(hostname) Displays the host name for the device. $(domain) Displays the domain name for the device. $(bold) Indicates that the next text is a bold text. Using this token again indicates the end of the bold text. $(inverse) Indicates that the next text is an inverse text. Using this token again indicates the end of the inverse text. $(contact) Displays the system contact string. $(location) Displays the system location string. $(macaddress) Displays the base MAC address of the device.User Interface Commands 57 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Use the no login-banner line configuration command to disable the Login banner on a particular line or lines. Example The following example sets a Login banner that uses tokens. The percent sign (%) is used as a delimiting character. Note that the $(token) syntax is replaced by the corresponding configuration variable. Device(config)# banner login % Enter TEXT message. End with the character '%'. You have entered $(hostname).$(domain) % When the login banner is executed, the user will see the following banner: You have entered host123.ourdomain.com banner motd Use the banner motd command in Global Configuration mode to specify and enable a message-of-the-day banner. Use the no form of this command to delete the existing MOTD banner. Syntax banner motd d message-text d no banner motd Parameters • d—Delimiting character of your choice—a pound sign (#), for example. You cannot use the delimiting character in the banner message. • message-text—The message must start on a new line. You can enter multiline messages. You can include tokens in the form of $(token) in the message text. Tokens are replaced with the corresponding configuration variable. Tokens are described in the User Guidelines. The message can contain up to 2000 characters (after every 510 characters, you must press to continue).58 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration Disabled (no MOTD banner is displayed). Command Mode Global Configuration mode User Guidelines Follow this command with one or more blank spaces and a delimiting character of your choice. Then enter one or more lines of text, terminating the message with the second occurrence of the delimiting character. When a user connects to a device, the message-of-the-day (MOTD) banner appears first, followed by the login banner and prompts. After the user logs in to the device, the EXEC banner is displayed. Use tokens in the form of $(token) in the message text to customize the banner. The tokens are described in the table below: Use the no motd-banner line configuration command to disable the MOTD banner on a particular line or lines. Example The following example sets an MOTD banner that uses tokens. The percent sign (%) is used as a delimiting character. Note that the $(token) syntax is replaced by the corresponding configuration variable. Token Information displayed in the banner $(hostname) Displays the host name for the device. $(domain) Displays the domain name for the device. $(bold) Indicates that the next text is a bold text. Using this token again to indicates the end of the bold text. $(inverse) Indicates that the next text is an inverse text. Using this token again indicates the end of the inverse text. $(contact) Displays the system contact string. $(location) Displays the system location string. $(mac-address) Displays the base MAC address of the device.User Interface Commands 59 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Device(config)# banner motd % Enter TEXT message. End with the character '%'. $(bold)Upgrade$(bold) to all devices begins at March 12 % When the login banner is executed, the user will see the following banner: Upgrade to all devices begins at March 12 exec-banner Use the exec-banner command in Line Configuration mode to enable the display of exec banners. Use the no form of this command to disable the display of exec banners. Syntax exec-banner no exec-banner Parameters This command has no arguments or keywords. Default Configuration Disabled Command Mode Line Configuration mode Example console# configure console(config)# line console console(config-line)# exec-banner console(config-line)# exit console(config)# line telnet console(config-line)# exec-banner console(config-line)# exit60 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY console(config)# line ssh console(config-line)# exec-banner login-banner Use the login-banner command in Line Configuration mode to enable the display of login banners. Use the no form of this command to disable the display of login banners. Syntax login-banner no login-banner Parameters This command has no arguments or keywords. Default Configuration Enabled Command Mode Line Configuration mode Example console# configure console(config)# line console console(config-line)# login-banner console(config-line)# exit console(config)# line telnet console(config-line)# login-banner console(config-line)# exit console(config)# line ssh console(config-line)# login-bannerUser Interface Commands 61 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY motd-banner Use the motd-banner command in Line Configuration mode to enable the display of message-of-the-day banners. Use the no form of this command to disable the display of MOTD banners. Syntax motd-banner no motd-banner Parameters This command has no arguments or keywords. Default Configuration Enabled Command Mode Line Configuration mode Example console# configure console(config)# line console console(config-line)# motd-banner console(config-line)# exit console(config)# line telnet console(config-line)# motd-banner console(config-line)# exit console(config)# line ssh console(config-line)# motd-banner show banner Use the show banner command in EXEC mode to display the configuration of banners.62 User Interface Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\User_Interface.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show banner motd show banner login show banner exec Parameters This command has no arguments or keywords. Command Mode EXEC mode Examples Device> show banner motd Banner: MOTD Line SSH: Enabled Line Telnet: Enabled Line Console: Enabled 10000 giga ports switch console# console# show banner login ------------------------------------------------------------- Banner: Login Line SSH: Enabled Line Telnet: Enabled Line Console: Enabled console# console# show banner exec Banner: EXEC Line SSH: Enabled Line Telnet: Enabled Line Console: Enabled console#Macro Commands 63 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Macro.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 3 Macro Commands macro name Use the Macro Name Global Configuration mode command to create a user defined macro. Use the no form of this command to delete the macro definition. Syntax macro name [macro-name] no macro name [macro-name] Parameters macro-name—Name of the macro. Macro names are case sensitive. Default Configuration The command has no default setting. Command Mode Global Configuration mode User Guidelines A macro can contain up to 3000 characters and up to 200 lines. Enter one macro command per line. Use the @ character to end the macro. Use the # character at the beginning of a line to enter comment text within the macro. You can define mandatory keywords within a macro by using a help string to specify the keywords. Enter #macro keywords word to define the keywords that are available for use with the macro. The keyword name is case sensitive. You can enter up to three keywords separated by a space. Only the first three 64 Macro Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Macro.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY keywords are visible if you enter more than three macro keywords. The command can be anywhere within the macro. When creating a macro, do not use the exit or end commands or change the command mode using interface interface-id. Doing so might cause commands that follow exit, end or interface interface-id to be executed in a different command mode. You can modify a macro by creating a new macro with the same name as the existing macro. The newer macro overwrites the existing macro. Examples The following example shows how to create a macro that defines the duplex mode and speed: Switch(config) # macro name dup Enter macro commands one per line. End with the character ‘@’. macro description dup duplex full speed auto The following example shows how to create a macro with #macro keywords: Switch(config) # macro name duplex Enter macro commands one per line. End with the character ‘@’. macro description duplex duplex $DUPLEX speed $SPEED #macro keywords $ DUPLEX $ SPEED @ The following example shows how to apply the macros to an interface: Switch(config-if) # macro apply duplex $DUPLEX full $SPEED auto Switch(config-if) # macro apply duplex ? WORDkeyword to replace with value e.g. $DUPLEX, $SPEED Macro Commands 65 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Macro.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Switch(config-if) # macro apply duplex $DUPLEX ? WORDValue of the first keyword to replace Switch(config-if) # macro apply duplex $DUPLEX full $SPEED ? WORDValue of the second keyword to replace macro apply Use the macro apply interface configuration command to apply a macro to an interface or to apply and trace a macro configuration on an interface. Syntax macro {apply | trace} macro-name [parameter {value}] [parameter {value}] [parameter {value}] Parameters • apply—Apply a macro to the specific interface. • trace—Apply and trace a macro to the specific interface. • macro-name—Specify the name of the macro. • parameter—(Optional) Specify unique parameter values that are specific to the interface. You can enter up to three keyword-value pairs. Parameter keyword matching is case sensitive. All matching occurrences of the keyword are replaced with the corresponding value. Default Configuration The command has no default setting. Command Mode Interface Configuration mode User Guidelines You can use the macro trace macro-name Interface Configuration command to apply and show the macros running on an interface or to debug the macro to find any syntax or configuration errors. If a command fails because of a syntax error or a configuration error the macro continues to apply t) in the interface. Use the parameter value 66 Macro Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Macro.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY keywords to designate values specific to the interface when creating a macro that requires the assignment of a unique value. Keyword matching is case sensitive. All matching occurrences of the keyword are replaced with the corresponding value. Any full match of a keyword, even if it is part of a large string, is considered a match and replaced by the corresponding value. Some macros might contain keywords that require a parameter value. You can use the macro apply macro-name command to display a list of any required values in the macro. If you apply a macro without entering the keyword values, the commands are invalid and are therefore not applied. When you apply a macro to an interface, the macro name is automatically added to the interface. You can display the applied commands and macro names by using the show running-configuration interface interface-id user EXEC mode command. A macro applied to an interface range behaves the same way as a macro applied to a single interface. When a macro is applied to an interface range, it is applied sequentially to each interface within the range. If a macro command fails on one interface, it is nonetheless applied to the remaining interfaces. Example Switch(config) # interface gi1/0/2 Switch(config-if) # macro trace dup Applying command… ‘duplex full’ Applying command… ‘speed auto’ Switch(config) # interface gi1/0/2 Switch(config-if) # macro apply duplex $DUPLEX full $SPEED auto Switch(config-if) # exit Switch(config) # interface gi1/0/3 Switch(config-if) # macro apply dup Switch(config-if) # exitMacro Commands 67 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Macro.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY macro description Use the macro description Interface Configuration mode command to enter a description about which macros are applied to an interface. Use the no form of this command to remove the description. Syntax macro description text no macro description Parameters text—Description text. The text can contain up to 160 characters. Default Configuration The command has no default setting. Command Mode Interface Configuration mode User Guidelines When multiple macros are applied on a single interface, the description text is a concatenation of texts from a number of previously applied macros. You can verify your setting by entering the show parser macro description privileged EXEC modecommand. Example Switch(config) # interface gi1/0/2 Switch(config-if) # macro apply dup Switch(config-if) # end Switch(config) # interface gi1/0/3 Switch(config-if) # macro apply duplex $DUPLEX full $SPEED auto Switch(config-if) # end Switch # show parser macro description InterfaceMacro Description -----------------------------------------------------------------68 Macro Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Macro.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY 1/2 dup 1/3 duplex ----------------------------------------------------------------- Switch(config) # interface gi1/0/2 Switch(config-if) # no macro description Switch(config-if) # end Switch # show parser macro description InterfaceMacro Description ----------------------------------------------------------------- 1/3 duplex ----------------------------------------------------------------- macro global Use the macro global Global Configuration command to apply a macro to a switch or to apply and trace a macro configuration on a switch. Syntax macro global {apply | trace} macro-name [parameter {value}] [parameter {value}] [parameter {value}] Parameters • apply—Apply a macro to the switch. • trace—Apply and trace a macro to the switch. • macro-name—Specify the name of the macro. • paramete—(Optional) Specify unique parameter values that are specific to the switch. You can enter up to three keyword-value pairs. Parameter keyword matching is case sensitive. All matching occurrences of the keyword are replaced with the corresponding value. Default Configuration The command has no default setting. Command Mode Global Configuration modeMacro Commands 69 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Macro.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines You can use the macro global trace macro-name Global Configuration mode command to apply and show the macros running on the switch or to debug the macro in order to locate any syntax or configuration errors. If a command fails because of a syntax error or a configuration error when you apply a macro, the macro nonetheless continues to apply the remaining commands to the interface. Use the parameter value keywords to designate values specific to the switch when creating a macro that requires the assignment of unique value. Keyword matching is case sensitive. All matching occurrences of the keyword are replaced with the corresponding value. Any full match of a keyword, even if it is part of a large string, is considered a match and replaced by the corresponding value. Some macros might contain keywords that require a parameter value. You can use the macro global apply macro-name command to display a list of any required values in the macro. If you apply a macro without entering the keyword values, the commands are considered invalid and are not applied. When you apply a macro to the switch, the macro name is automatically added to the switch. You can display the applied commands and macro names by using the show running-configuration interface user EXEC mode command. macro global description Use the macro global description Global Configuration command to enter a description about which macros are applied to the switch. Use the no form of this command to remove the description. Syntax macro global description text no macro global description Parameters text—Description text. The text can contain up to 160 characters.70 Macro Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Macro.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The command has no default setting. Command Mode Global Configuration mode User Guidelines When multiple global macros are applied to a switch, the global description text is a concatenation of texts from a number of previously applied macros. You can verify your settings by entering the show parser macro description privileged EXEC mode command. show parser macro Use the show parser macro User EXEC mode command to display the parameters for all configured macros or for one macro on the switch. Syntax show parser macro [{brief | description [interface interface-id] | name macro-name}] Parameters • brief—(Optional) Display the name of each macro. • description [interface]—(Optional) Display all macro descriptions. • interface-id—Or the description of a specific interface. • name macro-name—(Optional) Display information about a single macro identified by the macro name. Command Mode User EXEC modeSystem Management Commands 71 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 4 System Management Commands ping Use the ping command to send ICMP echo request packets to another node on the network. Syntax ping [ip] {ipv4-address | hostname} [size packet_size] [count packet_count] [timeout time_out] ping ipv6 {ipv6-address | hostname} [size packet_size] [count packet_count] [timeout time_out] Parameters • ip—Use IPv4 to check the network connectivity. • ipv6—Use IPv6 to check the network connectivity. • ipv4-address—IPv4 address to ping. • ipv6-address—Unicast or multicast IPv6 address to ping. When the IPv6 address is a Link Local address (IPv6Z address), the outgoing interface name must be specified. Refer to the User Guidelines for the interface name syntax. • hostname—Hostname to ping (160 characters. Maximum label size: 63.) • packet_size—Number of bytes in the packet not including the VLAN tag. The default is 64 bytes. (IPv4:64-1518, IPv6: 68-1518) • packet_count—Number of packets to send, from 1 to 65535 packets. The default is 4 packets. If 0 is entered, it pings until stopped (0–65535). • time-out—Timeout in milliseconds to wait for each reply, from 50 to 65535 milliseconds. The default is 2000 milliseconds (50–65535).72 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode EXEC mode User Guidelines Press Esc to stop pinging. Following are sample results of the ping command: • Destination does not respond—If the host does not respond, a “no answer from host” appears within 10 seconds. • Destination unreachable—The gateway for this destination indicates that the destination is unreachable. • Network or host unreachable—The switch found no corresponding entry in the route table. The format of an IPv6Z address is: % • interface-name = vlan | ch | isatap | | 0 • integer = | • decimal-number = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 • physical-port-name = Designated port number, for example gi1/0/1 When using the ping ipv6 command to check network connectivity of a directly attached host using its link local address, the egress interface may be specified in the IPv6Z format. If the egress interface is not specified, the default interface is selected. Specifying interface zone=0 is equivalent to not defining an egress interface. When using the ping ipv6 command with MC address, the information displayed is taken from all received echo responses. Examples Console> ping ip 10.1.1.1 Pinging 10.1.1.1 with 64 bytes of data: 64 bytes from 10.1.1.1: icmp_seq=0. time=11 ms 64 bytes from 10.1.1.1: icmp_seq=1. time=8 ms 64 bytes from 10.1.1.1: icmp_seq=2. time=8 msSystem Management Commands 73 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 64 bytes from 10.1.1.1: icmp_seq=3. time=7 ms ----10.1.1.1 PING Statistics---- 4 packets transmitted, 4 packets received, 0% packet loss round-trip (ms) min/avg/max = 7/8/11 Console> ping ip yahoo.com Pinging yahoo.com [66.218.71.198] with 64 bytes of data: 64 bytes from 10.1.1.1: icmp_seq=0. time=11 ms 64 bytes from 10.1.1.1: icmp_seq=1. time=8 ms 64 bytes from 10.1.1.1: icmp_seq=2. time=8 ms 64 bytes from 10.1.1.1: icmp_seq=3. time=7 ms ----10.1.1.1 PING Statistics---- 4 packets transmitted, 4 packets received, 0% packet loss round-trip (ms) min/avg/max = 7/8/11 Console> ping ip oob/176.16.1.1 Pinging oob/176.16.1.1 with 64 bytes of data: 64 bytes from oob/176.16.1.1: icmp_seq=0. time=5 ms 64 bytes from oob/176.16.1.1: icmp_seq=1. time=5 ms 64 bytes from oob/176.16.1.1: icmp_seq=2. time=5 ms 64 bytes from oob/176.16.1.1: icmp_seq=3. time=5 ms ----10.1.1.1 PING Statistics---- 4 packets transmitted, 4 packets received, 0% packet loss round-trip (ms) min/avg/max = 5/5/5 console> ping ipv6 3003::11 Pinging 3003::11 with 64 bytes of data: 64 bytes from 3003::11: icmp_seq=1. time=0 ms 64 bytes from 3003::11: icmp_seq=2. time=50 ms 64 bytes from 3003::11: icmp_seq=3. time=0 ms74 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY 64 bytes from 3003::11: icmp_seq=4. time=0 ms ----3003::11 PING Statistics---- 4 packets transmitted, 4 packets received, 0% packet loss round-trip (ms) min/avg/max = 0/12/50 console> ping ipv6 FF02::1 Pinging FF02::1 with 64 bytes of data: 64 bytes from 3003::11: icmp_seq=1. time=0 ms 64 bytes from 3003::33: icmp_seq=1. time=70 ms 64 bytes from 3003::11: icmp_seq=2. time=0 ms 64 bytes from 3003::55: icmp_seq=1. time=1050 ms 64 bytes from 3003::33: icmp_seq=2. time=70 ms 64 bytes from 3003::55: icmp_seq=2. time=1050 ms 64 bytes from 3003::11: icmp_seq=3. time=0 ms 64 bytes from 3003::33: icmp_seq=3. time=70 ms 64 bytes from 3003::11: icmp_seq=4. time=0 ms 64 bytes from 3003::55: icmp_seq=3. time=1050 ms 64 bytes from 3003::33: icmp_seq=4. time=70 ms 64 bytes from 3003::55: icmp_sq=4. time=1050 ms ---- FF02::1 PING Statistics---- 4 packets transmitted, 12 packets received traceroute To discover (?) the routes that packets will take when traveling to their destination, use the traceroute EXEC command. Syntax traceroute ip {ipv4-address | hostname} [size packet_size] [ttl max-ttl] [count packet_count] [timeout time_out] [source ip-address] [tos tos] traceroute ipv6 {ipv6-address | hostname} [size packet_size] [ttl max-ttl] [count packet_count] [timeout time_out] [source ip-address] [tos tos]System Management Commands 75 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • ip—Use IPv4 to discover the route. • ipv6—Use IPv6 to discover the route. • ipv4-address—IPv4 address of the destination host. (Range: Valid IP address) • ipv6-address—IPv6 address of the destination host. • hostname—Hostname of the destination host. (Range: 1–160 characters. Maximum label size: 63.) • packet_size—Number of bytes in the packet not including the VLAN tag. The default is 64 bytes. (IPv4:64-1518, IPv6: 68-1518) • ttl max-ttl—The largest TTL value that can be used. The default is 30. The traceroute command terminates when the destination is reached or when this value is reached. (Range: 1–255) • count packet_count—The number of probes to be sent at each TTL level. The default count is 3. (Range: 1–10) • timeout time_out—The number of seconds to wait for a response to a probe packet. The default is 3 seconds. (Range: 1–60) • source ip-address—One of the interface addresses of the device to use as a source address for the probes. The device will normally pick what it feels is the best source address to use. (Range: Valid IP address) • tos tos—The Type-Of-Service byte in the IP Header of the packet.(Range: 0—255) Command Mode EXEC mode User Guidelines The traceroute command works by taking advantage of the error messages generated by routers when a datagram exceeds its time-to-live (TTL) value. The traceroute command starts by sending probe datagrams with a TTL value of one. This causes the first router to discard the probe datagram and send back an error message. The traceroute command sends several probes at each TTL level and displays the round-trip time for each. 76 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY The traceroute command sends out one probe at a time. Each outgoing packet can result in one or two error messages. A "time exceeded” error message indicates that an intermediate router has seen and discarded the probe. A "destination unreachable" error message indicates that the destination node has received the probe and discarded it because it could not deliver the packet. If the timer goes off before a response comes in, the traceroute command prints an asterisk (*). The traceroute command terminates when the destination responds, when the maximum TTL is exceeded, or when the user interrupts the trace with Esc. The traceroute command is not relevant to IPv6 link local addresses. Example Router> traceroute ip umaxp1.physics.lsa.umich.edu Type Esc to abort. Tracing the route to umaxp1.physics.lsa.umich.edu (141.211.101.64) 1 i2-gateway.stanford.edu (192.68.191.83) 0 msec 0 msec 0 msec 2 STAN.POS.calren2.NET (171.64.1.213) 0 msec 0 msec 0 msec 3 SUNV--STAN.POS.calren2.net (198.32.249.73) 1 msec 1 msec 1 msec 4 Abilene--QSV.POS.calren2.net (198.32.249.162) 1 msec 1 msec 1 msec 5 kscyng-snvang.abilene.ucaid.edu (198.32.8.103) 33 msec 35 msec 35 msec 6 iplsng-kscyng.abilene.ucaid.edu (198.32.8.80) 47 msec 45 msec 45 msec 7 so-0-2-0x1.aa1.mich.net (192.122.183.9) 56 msec 53 msec 54 msec 8 atm1-0x24.michnet8.mich.net (198.108.23.82) 56 msec 56 msec 57 msec 9 * * * 10 A-ARB3-LSA-NG.c-SEB.umnet.umich.edu (141.211.5.22) 58 msec 58 msec 58 msec 11 umaxp1.physics.lsa.umich.edu (141.211.101.64) 62 msec 63 msec 63 msec Trace completedSystem Management Commands 77 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes the significant fields shown in the display: The following are characters that can appear in the traceroute command output: telnet The telnet EXEC mode command enables logging on to a host that supports Telnet. Syntax telnet {ip-address | hostname} [port] [keyword ...] Field Description 1 Indicates the sequence number of the router in the path to the host. i2-gateway.stanford.edu Host name of this router. 192.68.191.83 IP address of this router. 1 msec 1 msec 1 msec Round-trip time for each of the probes that are sent. Field Description * The probe timed out. ? Unknown packet type. A Administratively unreachable. Usually, this output indicates that an access list is blocking traffic. F Fragmentation required and DF is set. H Host unreachable. N Network unreachable. P Protocol unreachable. Q Source quench. R Fragment reassembly time exceeded S Source route failed. U Port unreachable. 78 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • ip-address—Specifies the destination host IP address. • hostname—Specifies the destination host name. (Length: 1-160 characters. Maximum label length: 63 characters.) • port—Specifies the decimal TCP port number or one of the keywords listed in the Ports table in the User Guidelines. • keyword—Specifies the one or more keywords listed in the Keywords table in the User Guidelines. Default Configuration The default port is the Telnet port (23) on the host. By default, Telnet is enabled. Command Mode EXEC mode User Guidelines Telnet software supports special Telnet commands in the form of Telnet sequences that map generic terminal control functions to operating systemspecific functions. To enter a Telnet sequence, press the escape sequence keys (Ctrl-shift-6) followed by a Telnet command character. Special Telnet Sequences At any time during an active Telnet session, available Telnet commands can be listed by pressing the Ctrl-shift-6-? keys at the system prompt. Telnet Sequence Purpose Ctrl-shift-6-b Break Ctrl-shift-6-c Interrupt Process (IP) Ctrl-shift-6-h Erase Character (EC) Ctrl-shift-6-o Abort Output (AO) Ctrl-shift-6-t Are You There? (AYT) Ctrl-shift-6-u Erase Line (EL)System Management Commands 79 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY A sample of this list follows. Note that the Ctrl-shift-6 sequence appears as ^^ on the screen. Console> ‘Ctrl-shift-6’ ? [Special telnet escape help] ^^ B sends telnet BREAK ^^ C sends telnet IP ^^ H sends telnet EC ^^ O sends telnet AO ^^ T sends telnet AYT ^^ U sends telnet EL Ctrl-shift-6 x suspends the session (return to system command prompt) Several concurrent Telnet sessions can be opened, enabling switching between the sessions. To open a subsequent session, the current connection has to be suspended by pressing the escape sequence keys (Ctrl-shift-6) and x to return to the system command prompt. Then open a new connection with the telnet EXEC mode command. This command lists concurrent Telnet connections to remote hosts that were opened by the current Telnet session to the local device. It does not list Telnet connections to remote hosts that were opened by other Telnet sessions. Keywords Table Options Description /echo Enables local echo. /quiet Prevents onscreen display of all messages from the software. /source-interface Specifies the source interface.80 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Ports Table /stream Turns on stream processing, which enables a raw TCP stream with no Telnet control sequences. A stream connection does not process Telnet options and can be appropriate for connections to ports running UNIX-to-UNIX Copy Program (UUCP) and other non-Telnet protocols. Ctrl-shift-6 x Returns to the System Command Prompt. Keyword Description Port Number BGP Border Gateway Protocol 179 chargen Character generator 19 cmd Remote commands 514 daytime Daytime 13 discard Discard 9 domain Domain Name Service 53 echo Echo 7 exec Exec 512 finger Finger 79 ftp File Transfer Protocol 21 ftp-data FTP data connections 20 gopher Gopher 70 hostname NIC hostname server 101 ident Ident Protocol 113 irc Internet Relay Chat 194 klogin Kerberos login 543 kshell Kerberos shell 544 login Login 513 lpd Printer service 515 nntp Network News Transport Protocol 119 Options DescriptionSystem Management Commands 81 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays logging in to IP address 176.213.10.50 via Telnet. Console> telnet 176.213.10.50 Esc U sends telnet EL resume The resume EXEC mode command enables switching to another open Telnet session. Syntax resume [connection] Parameters connection—Specifies the connection number. (Range: 1-4 connections.) pim-auto-rp PIM Auto-RP 496 pop2 Post Office Protocol v2 109 pop3 Post Office Protocol v3 110 smtp Simple Mail Transport Protocol 25 sunrpc Sun Remote Procedure Call 111 syslog Syslog 514 tacacs TAC Access Control System 49 talk Talk 517 telnet Telnet 23 time Time 37 uucp Unix-to-Unix Copy Program 540 whois Nickname 43 www World Wide Web 80 Keyword Description Port Number82 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The default connection number is that of the most recent connection. Command Mode EXEC mode Example The following command switches to open Telnet session number 1. Console> resume 1 hostname The hostname Global Configuration mode command specifies or modifies the device host name. Use the no form of the command to remove the existing host name. Syntax hostname name no hostname Parameters Name—specifies The Device Host Name. (Length: 1-160 Characters. Maximum label length: 63 characters.) Default Configuration No host name is defined. Command Mode Global Configuration mode Example The following example specifies the device host name as ‘enterprise’. Console(config)# hostname enterprise enterprise(config)#System Management Commands 83 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY reload The reload Privileged EXEC mode command reloads the operating system. Syntax reload [slot stack-member-number] Command Mode Privileged EXEC mode Parameters stack-member-number —Specifies the new master unit number. (Range: 1–8). If unspecified, reloads all the units. Example The following example reloads the operating system on all units. Console# reload This command will reset the whole system and disconnect your current session. Do you want to continue? (y/n) [n] stack master The stack master Global Configuration mode command forces a stack master selection. Use the no form of this command to restore the default configuration. Syntax stack master unit unit no stack master Parameters unit —Specifies the new master unit number. (Range: 1–2) Default Configuration The default is no forced master.84 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode Example The following example forces the stack master to be unit 2. Console(config)# stack master unit 2 system light Use the system light EXEC command to light LEDs on a specific unit. Syntax system light [unit unit-number] [duration seconds] system light stop Parameters • unit-number—Specify unit number or all. • seconds—The number of seconds to light the LEDs. If unspecified, defaults to 5 seconds. (Range: 2–6) • stop—Stop lighting the LEDs. Command Mode EXEC mode switch renumber Use the switch renumber Global Configuration command to change the unit ID of a specific unit. Syntax switch current-unit-number renumber new-unit-number Parameters • current-unit-number—Specify Unit number. (Range: 1–8)System Management Commands 85 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • new-unit-number—The new unit number. (Range: 1–8) Command Mode Global Configuration mode show switch The show switch EXEC mode command displays stack status information for the stack or stack member. Syntax show switch [stack-member-number] Parameters stack-member-number— Specifies the unit number. (Range: 1–6) Command Mode EXEC mode Example The following examples display the stack status information. Console> show switch Unit ---- 1 3 4 5 6 7 8 2 MAC Address ----------------- 00:00:b0:87:12:11 00:00:b0:87:12:13 00:00:b0:87:12:14 00:00:b0:87:12:15 00:00:b0:87:12:16 00:00:b0:87:12:17 00:00:b0:87:12:18 00:00:b0:87:12:12 SW ------ 3.30 3.30 3.30 3.30 3.30 3.30 3.30 3.30 Master ------ Enabled Forced Enabled Enabled Enabled Enabled Enabled Enabled Uplink ----- 2 1 3 4 5 6 7 8 Down link ----- 3 4 5 6 7 8 2 1 Status ------ Slave Master Slave Slave Slave Slave Slave Slave86 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY service cpu-utilization The service cpu-utilization Global Configuration mode command enables measuring CPU utilization. Use the no form of this command to restore the default configuration. Syntax service cpu-utilization no service cpu-utilization Default Configuration Measuring CPU utilization is disabled. Command Mode Global Configuration mode User Guidelines Use the show cpu utilization Privileged EXEC command to view information on CPU utilization. Configured order: Unit 1 at Top, Unit 2 at bottom Console> show switch 1 Unit 1: MAC address: 00:00:b0:87:12:11 Master: Forced. Product: Fonseca 48. Software: 3.30 Uplink unit: 8. Downlink unit: 2. Status: Master Active image: image-1. Selected for next boot: image-2.System Management Commands 87 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables measuring CPU utilization. Console(config)# service cpu-utilization show cpu utilization The show cpu utilization Privileged EXEC mode command displays information about CPU utilization. Syntax show cpu utilization Command Mode Privileged EXEC mode User Guidelines Use the service cpu-utilization Global Configuration mode command to enable measuring CPU utilization. Example The following example displays CPU utilization information. Console# show cpu utilization CPU utilization service is on. CPU utilization -------------------------------------------------- five seconds: 5%; one minute: 3%; five minutes: 3% clear cpu counters The clear cpu counters EXEC mode command clears traffic counters to and from the CPU. Syntax clear cpu counters88 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode EXEC mode Example The following example clears the CPU traffic counters. Console# clear cpu counters service cpu-counters The service cpu-counters Global Configuration mode command enables traffic counting to and from the CPU. To disable counting, use the no form of this command. Syntax service cpu-counters no service cpu-counters Command Mode Global Configuration mode User Guidelines Use the show cpu counters command to display the CPU traffic counters. Example The following example enables counting CPU traffic. Console(config)# service cpu-counters show cpu counters The show cpu counters EXEC mode command displays traffic counter information to and from the CPU. Syntax show cpu countersSystem Management Commands 89 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode EXEC mode User Guidelines Use the service cpu-counters command to enable traffic counting to and from the CPU. Example The following example displays the CPU traffic counters. Console# show cpu counters CPU counters are active. In Octets: 987891 In Unicast Packets: 3589 In Multicast Packets: 29 In Broadcast Packets: 8 Out Octets: 972181 Out Unicast Packets: 3322 Out Multicast Packets: 22 Out Broadcast Packets: 8 show users The show users EXEC mode command displays information about the active users. Syntax show users Command Mode EXEC mode90 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays information about the active users. show sessions The show sessions EXEC mode command displays open Telnet sessions. Syntax show sessions Command Mode EXEC mode User Guidelines The command displays Telnet sessions to remote hosts opened by the current Telnet session to the local device. It does not display Telnet sessions to remote hosts opened by other Telnet sessions to the local device. Console# show users Username ---------- Bob John Robert Betty Sam Protocol ----------- Serial SSH HTTP Telnet Location ------------ 172.16.0.1 172.16.0.8 172.16.1.7 172.16.1.6System Management Commands 91 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays open Telnet sessions. The following table describes significant fields shown above. show system The show system EXEC mode command displays system information. Syntax show system [unit unit] Parameters unit unit — Specifies the unit number. (Range: 1–8) Command Mode EXEC mode Console# show sessions Connection ---------- 1 2 Host ------------- Remote router 172.16.1.2 Address ---------- 172.16.1.1 172.16.1.2 Port ----- 23 23 Byte ---- 89 8 Field Description Connection The connection number. Host The remote host to which the device is connected through a Telnet session. Address The remote host IP address. Port The Telnet TCP port number. Byte The number of unread bytes for the user to see on the connection.92 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the system information. console# show system Unit Type ---- ---------------------- 1 PowerConnect 5524 2 PowerConnect 5524 3 PowerConnect 5524 4 PowerConnect 5524 5 PowerConnect 5524 6 PowerConnect 5524 7 PowerConnect 5524 8 PowerConnect 5524 Unit Main Power Supply Redundant Power Supply ---- ----------------- ---------------------- 1 OK 2 OK 3 OK 4 OK 5 OK 6 OK 7 OK 8 OK NOT OPERATIONAL Unit Fans Status ---- ------------- 1 OK 2 OK 3 OK 4 OK 5 IDLE 6 OK 7 OK 8 FAILURESystem Management Commands 93 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Unit Temperature (Celsius) Temperature Sensor Status ---- ------------------------- --------------- 1 47 OK 2 45 OK 3 49 OK 4 36 OK 5 35 OK 6 45 OK 7 40 OK 8 56 OK Unit Up time ---- --------------- 1 00,00:31:24 2 00,00:31:19 3 00,00:31:24 4 00,00:31:24 5 00,00:31:24 6 00,00:31:24 7 00,00:31:25 8 00,00:31:25 console# show system unit 2 System Type: PowerConnect 5548 System Up Time (days,hour:min:sec): 08,23:03:46 System Contact: System Name: System Location: System MAC Address: 00:99:88:66:33:33 System Object ID: 1.3.6.1.4.1.674.10895.3031 Type: PowerConnect 5548 Main Power Supply Status: OK94 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Fans Status: OK Unit Temperature (Celsius) Status ------------- ------------------- ------------- 2 42 OK show version The show version EXEC mode command displays system version information. Syntax show version [unit unit] Parameters unit unit — Specifies the unit number. (Range: 1–8) Command Mode EXEC mode Example The following example displays system version information. console > show version Unit SW Version Boot Version HW Version ------ ----------- ------------ ---------- 1 3.131 2.178 1.0.0 2 3.131 2.178 1.0.0 system resources routing The system resources routing Global Configuration mode command configures the routing table maximum size. Use the no form of this command to return to the default size. Syntax system resources routing routes hosts interfacesSystem Management Commands 95 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY no system resources routing Parameters • routes—Specifies the maximum number of remote networks in the routing table. • hosts—Specifies the maximum number of directly attached hosts. • interfaces—Specifies the maximum number of IP interfaces. Default Configuration Hosts: 200, Routes: 64, IP Interfaces: 32 Command Mode Global Configuration mode User Guidelines The settings are effective after reboot. Example The following example configures the routing table maximum size. Console# system resources routing 20 23 5 show system resources routings The show system resources routings EXEC mode command displays system routing resources information. Syntax show system resources routings Command Mode EXEC mode96 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the system routing resources information. Console> show system resources routings Parameters Current value After reboot Value -------------- ---------------- ------------------- Hosts: 100 100 Routes: 32 32 IP Interfaces: 32 32 show system tcam utilization The show system tcam utilization EXEC mode command displays the Ternary Content Addressable Memory (TCAM) utilization. Syntax show system tcam utilization [unit unit] Parameters unit unit—Specifies the unit number. (Range: 1–8) Command Mode EXEC mode Example The following example displays TCAM utilization information. Console> show system tcam utilization System: 75% Unit ---- 1 2 TCAM utilization [%] -------------------- 58 57System Management Commands 97 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show system defaults Use the show system defaults command to display system defaults. Syntax show system defaults [section] Parameters section—Show information for specific session only. Available values are: management, 802.1x, port, fdb, port-mirroring, spanning-tree, vlan, voicevlan, ip-addressing, network-security and qos-acl. Command Mode EXEC mode Examples console# show system defaults System Mode: Router Maximum units in stack: 8 # Management defaults Telnet: Enabled (Maximum 4 sessions, shared with SSH) SSH: Enabled (Maximum 4 sessions, shared with Telnet) HTTP: Enabled, port 80 (Maximum 27 sessions) HTTPS: Disabled SNMP: Enabled. User: first SNMP version: V3 SNMP Local Engine ID: 0000000001 SNMP Notifications: Enabled SNMP Authentication Notifications: Enabled Console: Enabled. Cryptographic keys are not generated HTTPS certificate is not generated Management ACL: No ACL is defined AAA Telnet authentication login: Local user data base98 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY AAA HTTP authentication login: Local data base AAA HTTPS authentication login: Local data base Radius accounting: Disabled Radius: No server is defined Tacacs: No server is defined Syslog: No server is defined Logging: Enabled Logging to console: Informational messages Logging to internal buffer: Informational messages Logging to file: Error messages Logging to remote server: Informational messages Maximum no. of syslog messages: 200 SNTP: supported SNTP Port No.: 123 SNTP Interface: Enabled IP Domain Naming System: Enabled DHCP Server: Enabled DHCP Auto Configuration: Enabled DHCP Option 67: Enabled DHCP Option 82: Disabled # IPv6 defaults # 802.1x defaults 802.1X is disabled Mode: Multiple host Guest VLAN: Not defined # Interface defaults in present unit 48 GE regular 2 10G fiberOptics PoE: Enabled POE mode: Port Limit Duplex: Full Negotiation: Enabled Flow control: OffSystem Management Commands 99 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Mdix mode: auto LAGs: No LAG is defined Storm control: Disabled Storm control mode: unknown unicast, broadcast, multicast Port security: Disabled LLDP: Enabled LLDPDU Handeling: Filtering Jumbo frames: Disabled Port-Channel Load Balancing: Layer 2 # Bridging defaults Maximum 16K entries Aging time: 5 minutes iSCSI: Enabled iSCSI cos: 5, with no remark # Multicast defaults Multicast filtering: Disabled IGMP snooping: Disabled IGMP Querier: Disabled Multicast TV Vlan Interface: disabled # Port monitoring defaults Port monitor is not defined Maximum source port: 4 Maximum destination ports for mirroring: 2 # Spanning tree defaults Spanning tree is Enabled Spanning tree mode is Classic Spanning tree interface: Enabled Port fast: Disabled BPDU handling: Filtering BPDU Guard: Disabled # Vlan defaults100 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Maximum Vlans: 4094 Default VLAN: Enabled Default VLAN id: 1 GVRP: Disabled Port mode: undefined PVID: 1 VLAN membership: 1 # Voice vlan defaults Voice VLAN: Disabled Cos: 6 with no remark OUI table: 00:E0:BB 3COM 00:03:6B Cisco 00:E0:75 Veritel 00:D0:1E Pingtel 00:01:E3 Simens 00:60:B9 NEC/Philips 00:0F:E2 Huawei-3COM 00:09:6E Avaya # Network security defaults DHCP snooping: Disabled ARP inspection: Disabled ARP inspection Validation: Disabled # DOS attacks # IP addressing defaults No IP interface is defined # QOS and ACLs defaults QoS mode is basic QoS Basic Trust Mode: CoS QoS Advanced Trust Mode: CoS-DSCP Queue default mapping:System Management Commands 101 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY cos qid: 0 2 1 1 2 1 3 3 4 4 5 5 6 6 7 7 show tech-support Use the show tech-support command to display system and configuration information you can provide to the Technical Assistance Center when reporting a problem. Syntax show tech-support [config] [memory] Parameters Memory—Displays memory and processor state data. Config—Displays switch configuration within the CLI commands supported on the device. Default Configuration By default, this command displays the output for technical-support-related show commands. Use keywords to specify the type of information to be displayed. If you do not specify any parameters, the system displays all configuration and memory data. Command Types Switch command. Command Mode EXEC mode102 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines Caution: Avoid running multiple show tech-support commands on a switch or multiple switches on the network segment. Doing so may cause starvation of some time sensitive protocols, like STP. The show tech-support command may timeout if the configuration file output takes longer to display than the configured session timeout time. If this happens, enter a set logout timeout value of 0 to disable automatic disconnection of idle sessions or enter a longer timeout value. The show tech-support command output is continuous, it does not display one screen at a time. To interrupt the output, press Esc. If you specify the config keyword, the show tech-support command displays a list of the commands supported on the device. If user specifies the memory keyword, the show tech-support command displays the output: flash info (dir if existed, or flash mapping) show bootvar buffers info (like print os buff) memory info (like print os mem) proc info (lie print os tasks) versions of software components show cpu utilization system fans always-on Use the system fans always-on Global Configuration command to set the system fans to On regardless of device temperature. Use the no form of the command to return to default. Syntax system fans always-on [unit unit] no system fans always-on Parameters unit unit—Unit number or all. If unspecified, defaults to all. (Range: 1–8)System Management Commands 103 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration Automatic mode; The system fan speed depends on the temperature of the device. Command Mode Global Configuration mode show system fans Use the show system fans EXEC command to view the fans’ status Syntax show system fans Command Mode EXEC mode Example console>show system fans Unit Temperature Speed Admin state Oper state (Celsius) (RPM) --- --------------- ---------- -------------- ----------- 1 30 8000 auto on 2 40 8000 on on asset-tag The asset-tag Global Configuration mode command assigns an asset-tag to a device. Use the no form of this command to restore the default setting. Syntax asset-tag [unit unit] tag no asset-tag [unit unit]104 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • unit —Specifies the unit number. (Range: 1–8) • tag—Specifies the device asset-tag. Default Configuration No asset tag is defined. The default unit number is the master unit number. Command Mode Global Configuration mode Example The following example assigns the asset-tag 2365491870 to the device. Console(config)# asset-tag 2365491870 show system id The show system id EXEC mode command displays the system identity information. Syntax show system id [unit unit] Parameters unit unit—Specifies the unit number. (Range: 1–8) Command Mode EXEC modeSystem Management Commands 105 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the system identity information. Console> show system id Unit Service tag Serial number Asset tag ------ ------------- ------------- ----------- 1 89788978 8936589782 7843678957 2 3216523877 5621987728106 System Management Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\System_Management.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYClock Commands 107 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 5 Clock Commands clock set The clock set Privileged EXEC mode command manually sets the system clock. Syntax clock set hh:mm:ss {[day month] | [month day]} year Parameters • hh:mm:ss—Specifies the current time in hours (military format), minutes, and seconds. (Range: hh: 0-23, mm: 0-59, ss: 0-59) • day—Specifies the current day of the month. (Range: 1-31) • month—Specifies the current month using the first three letters of the month name. (Range: Jan–Dec) • year—Specifies the current year. (Range: 2000–2037) Command Mode Privileged EXEC mode User Guidelines The user should enter the local clock time and date. Example The following example sets the system time to 13:32:00 on March 7th, 2005. Console# clock set 13:32:00 7 Mar 2005108 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY clock source The clock source Global Configuration mode command configures an external time source for the system clock. Use the no form of this command to disable the external time source. Syntax clock source {sntp} no clock source Parameters sntp—Specifies that an SNTP server is the external clock source. Default Configuration There is no external clock source. Command Mode Global Configuration mode Example The following example configures an SNTP server as an external time source for the system clock. Console(config)# clock source sntp clock timezone Use the clock timezone Global Configuration command to set the time zone for display purposes. Use the no form of this command to set the time to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT), which is the same. Syntax clock timezone zone hours-offset [minutes-offset]Clock Commands 109 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY no clock timezone Parameters • zone—The acronym of the time zone.(Range: Up to 4 characters) • hours-offset—Hours difference from UTC. (Range: (-12)–(+13)) • minutes-offset—Minutes difference from UTC. (Range: 0–59) Default Configuration Offset is 0. Acronym is empty. Command Mode Global Configuration mode User Guidelines The system internally keeps time in UTC, so this command is used only for display purposes and when the time is manually set. Example console(config)# clock timezone abc +2 minutes 32 clock summer-time Use one of the formats of the clock summer-time Global Configuration command to configure the system to automatically switch to summer time (daylight saving time). Use the no form of this command to configure the software not to automatically switch to summer time. Syntax clock summer-time zone recurring {usa | eu | {week day month hh:mm week day month hh:mm}} [offset] clock summer-time zone date date month year hh:mm date month year hh:mm [offset]110 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY clock summer-time zone date month date year hh:mm month date year hh:mm [offset] no clock summer-time Parameters • zone—The acronym of the time zone to be displayed when summer time is in effect. (Range: Up to 4 characters) • recurring—Indicates that summer time should start and end on the corresponding specified days every year. • date—Indicates that summer time should start on the first specific date listed in the command and end on the second specific date in the command. • usa—The summer time rules are the United States rules. • eu—The summer time rules are the European Union rules. • week—Week of the month. Can be 1–4, first, last. • day—Day of the week (first three letters by name, such as Sun). (characters) • date—Date of the month. (Range: 1–31) • month—Month (first three letters by name, such as Feb). (characters) • year—year (no abbreviation). (Range: 2000–2097) • hh:mm—Time (military format) in hours and minutes. (Range: hh:mmhh: 0-23, mm: 0-59) • offset—Number of minutes to add during summer time (default is 60). (Range: 1440) Default Configuration Summer time is disabled. Command Mode Global Configuration mode User Guidelines In both the date and recurring forms of the command, the first part of the command specifies when summer time begins, and the second part specifies Clock Commands 111 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY when it ends. All times are relative to the local time zone. The start time is relative to standard time. The end time is relative to summer time. If the starting month is chronologically after the ending month, the system assumes that you are in the southern hemisphere. USA rule for daylight saving time: • From 2007: • Start: Second Sunday in March • End: First Sunday in November • Time: 2 am local time • Before 2007: • Start: First Sunday in April • End: Last Sunday in October • Time: 2 am local time Example console(config)# clock summer-time abc date apr 1 2010 09:00 aug 2 2010 09:00 EU rule for daylight saving time: • Start: Last Sunday in March • End: Last Sunday in October • Time: 1.00 am (01:00) Greenwich Mean Time (GMT) sntp authentication-key The sntp authentication-key Global Configuration mode command defines an authentication key for Simple Network Time Protocol (SNTP). Use the no form of this command to remove the authentication key for SNTP. Syntax sntp authentication-key key-number md5 key-value no sntp authentication-key key-number112 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • key-number—Specifies the key number. (Range: 1–4294967295) • key-value—Specifies the key value. (Length: 1–8 characters) Default Configuration No authentication key is defined. Command Mode Global Configuration mode Examples The following example defines the authentication key for SNTP. Console(config)# sntp authentication-key 8 md5 ClkKey Device(config)# sntp authentication-key 8 md5 ClkKey Device(config)# sntp trusted-key 8 Device(config)# sntp authenticate sntp authenticate The sntp authenticate Global Configuration mode command enables authentication for received Simple Network Time Protocol (SNTP) traffic from servers. Use the no form of this command to disable the feature. Syntax sntp authenticate no sntp authenticate Default Configuration Authentication is disabled. Command Mode Global Configuration modeClock Commands 113 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines The command is relevant for both unicast and broadcast. Examples The following example enables authentication for received SNTP traffic. Console(config)# sntp authenticate Device(config)# sntp authentication-key 8 md5 ClkKey Device(config)# sntp trusted-key 8 Device(config)# sntp authenticate sntp trusted-key The sntp trusted-key Global Configuration mode command authenticates the system identity with which Simple Network Time Protocol (SNTP) synchronizes. Use the no form of this command to disable system identity authentication. Syntax sntp trusted-key key-number no sntp trusted-key key-number Parameters key-number—Specifies the key number of the authentication key to be trusted. (Range: 1–4294967295) Default Configuration No keys are trusted. Command Mode Global Configuration mode User Guidelines The command is relevant for both received unicast and broadcast.114 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Examples The following example authenticates key 8. Console(config)# sntp trusted-key 8 Device(config)# sntp authentication-key 8 md5 ClkKey Device(config)# sntp trusted-key 8 Device(config)# sntp authenticate sntp client poll timer The sntp client poll timer Global Configuration mode command sets the polling time for the Simple Network Time Protocol (SNTP) client. Use the no form of this command to restore the default configuration. Syntax sntp client poll timer seconds no sntp client poll timer Parameters seconds—Specifies the polling interval in seconds. (Range: 60–86400) Default Configuration The default polling interval is 1024 seconds. Command Mode Global Configuration mode Example The following example sets the polling time for the SNTP client to 120 seconds. Console(config)# sntp client poll timer 120Clock Commands 115 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY sntp broadcast client enable The sntp broadcast client enable Global Configuration mode command enables Simple Network Time Protocol (SNTP) broadcast clients. Use the no form of this command to disable SNTP broadcast clients. Syntax sntp broadcast client enable no sntp broadcast client enable Default Configuration The SNTP broadcast client is disabled. Command Mode Global Configuration mode User Guidelines Use the sntp client enable Interface Configuration mode command to enable the SNTP client on a specific interface. Example The following example enables the SNTP broadcast clients. s Console(config)# sntp broadcast client enable sntp anycast client enable The sntp anycast client enable Global Configuration mode command enables the SNTP anycast client. Use the no form of this command to disable the SNTP anycast client. Syntax sntp anycast client enable no sntp anycast client enable116 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The SNTP anycast client is disabled. Command Mode Global Configuration mode User Guidelines The polling time is configured with the sntp client poll timer Global Configuration mode command. Use the sntp client enable Interface Configuration mode command to enable the SNTP client on a specific interface. Example The following example enables SNTP anycast clients. Console(config)# sntp anycast client enable sntp client enable The sntp client enable Global Configuration mode command enables the Simple Network Time Protocol (SNTP) broadcast and anycast client on an interface. Use the no form of this command to disable the SNTP client. Syntax sntp client enable {interface-id} no sntp client enable {interface-id} Parameters interface-id—Specifies an interface ID, which can be one of the following types: Ethernet port, Port-channel or VLAN. Default Configuration The SNTP client is disabled on an interface. Command Mode Global Configuration modeClock Commands 117 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines The sntp broadcast client enable Global Configuration mode command globally enables broadcast clients. The sntp anycast client enable Global Configuration mode command globally enables anycast clients. Example The following example enables the SNTP broadcast and anycast client on gigabitethernet port gi1/0/3 Console(config)# sntp client enable gi1/0/3 sntp client enable (Interface) To enable the Simple Network Time Protocol (SNTP) broadcast and anycast client on an interface, use the sntp client enable Interface Configuration command. Use the no form of this command to disable the SNTP client. The sntp client enable Interface Configuration (Ethernet, Port-channel, VLAN) mode command enables the Simple Network Time Protocol (SNTP) broadcast and anycast client on an interface. Use the no form of this command to disable the SNTP client. Syntax sntp client enable no sntp client enable Default Configuration The SNTP client is disabled on an interface. Command Mode Interface Configuration (Ethernet, Port-channel, VLAN) mode User Guidelines The sntp broadcast client enable Global Configuration mode command globally enables broadcast clients.118 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY The sntp anycast client enable Global Configuration mode command globally enables anycast clients. Example The following example enables the SNTP broadcast and anycast client on an interface. Console(config-if)# sntp client enable sntp unicast client enable The sntp unicast client enable Global Configuration mode command enables the device to use Simple Network Time Protocol (SNTP) predefined unicast clients. Use the no form of this command to disable the SNTP unicast clients. Syntax sntp unicast client enable no sntp unicast client enable Default Configuration The SNTP unicast client is disabled. Command Mode Global Configuration mode User Guidelines Use the sntp server Global Configuration mode command to define SNTP servers. Example The following example enables the device to use Simple Network Time Protocol (SNTP) unicast clients. Console(config)# sntp unicast client enableClock Commands 119 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY sntp unicast client poll The sntp unicast client poll Global Configuration mode command enables polling for the Simple Network Time Protocol (SNTP) predefined unicast clients. Use the no form of this command to disable the polling for the SNTP client. Syntax sntp unicast client poll no sntp unicast client poll Default Configuration Polling is disabled. Command Mode Global Configuration mode User Guidelines Polling time is configured with the sntp client poll timer Global Configuration mode command. Example The following example enables polling for SNTP predefined unicast clients. Console(config)# sntp unicast client poll sntp server The sntp server Global Configuration mode command configures the device to use the Simple Network Time Protocol (SNTP) to request and accept Network Time Protocol (NTP) traffic from a specified server. Use the no form of this command to remove a server from the list of SNTP servers. Syntax sntp server {ipv4-address | ipv6-address | ipv6z-address | hostname} [poll] [key keyid]120 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY no sntp server {ipv4-address | ipv6-address | ipv6z-address | hostname} Parameters • ipv4-address—Specifies the server IPv4 address. • ipv6-address—Specifies the server IPv6 address. A Link Local address (IPv6Z address) can be defined. • pv6z-address—Specifies the IPv6Z address to ping. The IPv6Z address format is: ipv6-link-local-address}%{interface-name}. The subparameters are: • ipv6-link-local-address—Specifies the IPv6 Link Local address. • interface-name—Specifies the outgoing interface name. The interface name has the format: vlan {integer} | ch {integer} | isatap {integer} | {physical-port-name}. The subparameter integer has the format: {decimal-digit} | {integer}{decimal-digit}. (Range for the decimaldigit: 0–9) • hostname—Specifies the server hostname. Only translation to IPv4 addresses is supported. (Length: 1–158 characters. Maximum label length: 63 characters) • poll—Enables polling. • key keyid—Specifies the Authentication key to use when sending packets to this peer. (Range:1–4294967295) Default Configuration No servers are defined. Command Mode Global Configuration mode User Guidelines Up to 8 SNTP servers can be defined. The sntp unicast client enable Global Configuration mode command enables predefined unicast clients. The sntp unicast client poll Global Configuration mode command globally enables polling.Clock Commands 121 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Polling time is configured with the sntp client poll timer Global Configuration mode command. The format of an IPv6Z address is: %. interface-name = vlan | ch | isatap | | 0 integer = | decimal-number = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 physical-port-name = Designated port number, for example:gi1/0/16. If the egress interface is not specified, the default interface is selected. Specifying interface zone=0 is equal to not defining an egress interface. Example The following example configures the device to accept SNTP traffic from the server on 192.1.1.1. Console(config)# sntp server 192.1.1.1 sntp port The sntp port Global Configuration mode command specifies a Simple Network Time Protocol (SNTP) User Datagram Protocol (UDP) port. Use the no form of this command to use the SNTP server default port. Syntax sntp port port-number no sntp port Parameters port-number—Specifies the UDP port number used by an SNTP server. (Range 1–65535) Default Configuration The default port number is 123.122 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode Example The following example specifies that port 321 of the SNTP server is the UDP port. Console(config)# sntp port 321 show clock The show clock EXEC mode command displays the time and date from the system clock. Syntax show clock [detail] Parameters detail—Displays the TimeZone and SummerTime configuration. Command Mode EXEC mode Example The following example displays the system time and date. Console> show clock 15:29:03 PDT(UTC-7) Jun 17 2002 Time source is SNTP Console> show clock detail 15:29:03 PDT(UTC-7) Jun 17 2002 Time source is SNTP Time zone:Clock Commands 123 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Acronym is PST Offset is UTC-8 Summertime: Acronym is PDT Recurring every year. Begins at first Sunday of April at 2:00. Ends at last Sunday of October at 2:00. Offset is 60 minutes. DHCP timezone: Disabled Device> show clock detail 15:29:03 PDT(UTC-7) Jun 17 2002 Time source is SNTP Timezone (DHCP): Acronym is PST Offset is UTC-8 Timezone (static): Acronym is PST Offset is UTC-8 Summertime (Static): Acronym is PDT Recurring every year. Begins at first Sunday of April at 2:00. Ends at last Sunday of October at 2:00. Offset is 60 minutes. DHCP timezone: Enabled124 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show sntp configuration The show sntp configuration Privileged EXEC mode command displays the Simple Network Time Protocol (SNTP) configuration on the device. Syntax show sntp configuration Command Mode Privileged EXEC mode Example The following example displays the device’s current SNTP configuration. console# show sntp configuration SNTP port : 123 . Polling interval: 1024 seconds. No MD5 authentication keys. Authentication is not required for synchronization. No trusted keys. Unicast Clients: Enabled Unicast Clients Polling: Enabled Server Polling Encryption Key ----------------------------- ---------- -------------- 1.1.1.121 Disabled Disabled Broadcast Clients: disabled Anycast Clients: disabled No Broadcast Interfaces. console# show sntp status The show sntp status Privileged EXEC mode command displays the Simple Network Time Protocol (SNTP) servers status.Clock Commands 125 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show sntp status Command Mode Privileged EXEC mode Example The following examples display the SNTP servers status. Device# show sntp status Clock is synchronized, stratum 4, reference is 176.1.1.8, unicast Reference time is AFE2525E.70597B34 (00:10:22.438 PDT Jul 5 1993) Console# show sntp status Clock is synchronized, stratum 4, reference is 176.1.1.8, unicast Reference time is AFE2525E.70597B34 (00:10:22.438 PDT Jul 5 1993) Unicast servers: Server -------- 176.1.1.8 Status ------- Up Last response --------------------- 19:58:22.289 PDT Feb 19 2005 Offset [mSec] ----- 7.33 Delay [mSec] ------ 117.79 176.1.8.17 Unknown 12:17.17.987 PDT Feb 19 2005 8.98 189.19 Anycast server: Server -------- 176.1.11.8 Interface ------- VLAN 118 Status ----- Up Last response ------------- 9:53:21.789 PDT Feb 19 2005 Offset [mSec] ----- 7.19 Delay [mSec] ------ 119.89 Broadcast: Server --------- 176.9.1.1 Interface --------- VLAN 119 Last response ---------------------------- 19:17:59.792 PDT Feb 19 2002126 Clock Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Clock.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYConfiguration/Image File Commands 127 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 6 Configuration/Image File Commands copy The copy Privileged EXEC mode command copies files from a source to a destination. Syntax copy source-url destination-url [snmp] Parameters • source-url—Specifies the source file location URL or source file reserved keyword to be copied. (Length: 1–160 characters) • destination-url—Specifies the destination file URL or destination file reserved keyword. (Length: 1–160 characters) • snmp—Specifies that the destination/source file is in SNMP format. Used only when copying from/to startup-config. The following table displays URL options. Keyword Source or Destination flash:// Source or destination URL for flash memory. This is the default URL If a URL is specified without a prefix. running-config Currently running configuration file. startup-config Startup configuration file. image Image file. If specified as the source file, it is the active image file. If specified as the destination file, it is the non-active image file.128 Configuration/Image File Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Privileged EXEC mode User Guidelines The location of a file system dictates the format of the source or destination URL. The entire copying process may take several minutes and differs from protocol to protocol and from network to network. If the IPv6 address is a Link Local address (IPv6Z address), the outgoing interface name must be specified. The format of an IPv6Z address is: {ipv6- link-local-address}%{interface-name}. The subparameters are: • ipv6-link-local-address—Specifies the IPv6 Link Local address. boot Boot file. tftp:// Source or destination URL for a TFTP network server. The syntax for this alias is tftp://host/[directory]/filename. The host can be either an IP address or a host name. usb:// Copy to a file on the USB device. The syntax is: usb://directory/filename xmodem: Source for the file from a serial connection that uses the Xmodem protocol. unit://member/i mage Image file on one of the units. To copy from the master to all units, specify * in the member field. unit://member/ boot Boot file on one of the units. To copy from the master to all units, specify * in the member field unit://member/ startup-config Configuration file used during initialization (startup) on one of the units. null: Null destination for copies or files. A remote file can be copied to null to determine its size. mirror-config Mirrored configuration file WORD<1-128> Specify URL prefixes. Keyword Source or DestinationConfiguration/Image File Commands 129 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • interface-name—Specifies the outgoing interface name. The interface name has the format: vlan{integer} | ch{integer} | isatap{integer} | {physical-port-name}.The subparameter integer has the format: {decimaldigit} | {integer}{decimal-digit}. decimal-digit has the range 0–9 If the egress interface is not specified, the default interface is selected. Specifying interface zone=0 is equal to not defining an egress interface. Understanding Invalid Combinations of Source and Destination Some invalid combinations of source and destination exist. Specifically, if one of the following conditions exists: • The source file and destination file are the same file. • xmodem: is the destination file. The source file can be copied to image, boot and null: only. • tftp:// is the source file and destination file on the same copy. • *.prv files cannot be copied. • The source or destination is a slave unit (except for image and boot files).  mirror-config cannot be used as a destination The following table describes the copy characters: Copying an Image File from a Server to Flash Memory Use the copy source-url image command to copy an image file from a server to flash memory. Copying a Boot File from a Server to Flash Memory Use the copy source-url boot command to copy a boot file from a server to flash memory. Copying a Configuration File from a Server to the Running Configuration File Character Description ! For network transfers, indicates that the copy process is taking place. Each exclamation point indicates successful transfer of ten packets (512 bytes each). . For network transfers, indicates that the copy process timed out. Generally, several periods in a row means that the copy process may fail.s130 Configuration/Image File Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Use the copy source-url running-config command to load a configuration file from a network server to the running device configuration file. The commands in the loaded configuration file are added to those in the running configuration file as if the commands were typed in the command-line interface (CLI). The resulting configuration file is a combination of the previous running configuration and the loaded configuration files, with the loaded configuration file taking precedence. Copying a Configuration File from a Server to the Startup Configuration Use the copy source-url startup-config command to copy a configuration file from a network server to the device startup configuration file. The startup configuration file is replaced by the copied configuration file. Storing the Running or Startup Configuration on a Server Use the copy running-config destination-url command to copy the current configuration file to a network server using TFTP, . Use the copy startup-config destination-url command to copy the startup configuration file to a network server. Saving The Running Configuration To The Startup Configuration Use the copy running-config startup-config command to copy the running configuration to the startup configuration file. -Backing Up the Running Configuration or Startup Configuration to a Backup Configuration file Use the copy running-config file command to back up the running configuration to a backup configuration file. Use the copy startup-config file command to back up the startup configuration to a backup configuration file. Examples The following example copies system image file1 from the TFTP server 172.16.101.101 to a non-active image file. Console# copy tftp://172.16.101.101/file1 image Accessing file 'file1' on 172.16.101.101...Configuration/Image File Commands 131 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Loading file1 from 172.16.101.101: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! [OK] Copy took 0:01:11 [hh:mm:ss] Copying an Image from a Server to Flash Memory The following example copies a system image named file1 from the TFTP server with an IP address of 172.16.101.101 to a non-active image file. Router# copy tftp://172.16.101.101/file1 image Accessing file 'file1' on 172.16.101.101... Loading file1 from 172.16.101.101: !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!! !!!!! [OK] Copy took 0:01:11 [hh:mm:ss]132 Configuration/Image File Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY write memory Use the write memory Privileged EXEC mode command to save the running configuration to the startup configuration file. Syntax write memory Parameters This command has no arguments or keywords. Command Mode Privileged EXEC mode Examples The following example copies system image file1 from the TFTP server 172.16.101.101 to a non-active image file. Console# write memory Overwrite file [startup-config] ?[Yes/press any key for no]....15-Sep-2010 11:27 :48 %COPY-I-FILECPY: Files Copy - source URL running-config destination URL flas h://startup-config 15-Sep-2010 11:27:50 %COPY-N-TRAP: The copy operation was completed successfully Copy succeeded delete The delete Privileged EXEC mode command deletes a file from a flash memory device. Syntax delete urlConfiguration/Image File Commands 133 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters url—Specifies the location URL or reserved keyword of the file to be deleted. (Length: 1–160 characters) The following table displays keywords and URL prefixes: Command Mode Privileged EXEC mode User Guidelines *.sys, *.prv, image-1 and image-2 files cannot be deleted. Example The following example deletes the file called ‘test’ from the flash memory. Console# delete flash:test Delete flash:test? [confirm] pwd Use the pwd Privileged EXECmode command to display a full, clarified path to the current directory. Parameters This command has no arguments or keywords. Command Mode EXEC mode Keyword Source or Destination flash:// URL of the flash memory. This is the default URL if a URL is specified without a prefix. usb:// URL of the USB memory. startup-config Startup configuration file. WORD Specify URL prefixes.134 Configuration/Image File Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY dir The dir Privileged EXEC mode command displays the list of files on a flash file system. Syntax dir dir [directory-path] Command Mode Privileged EXEC mode Example The following example displays the list of files on a flash file system Total size of flash: 33292288 bytes Free size of flash: 20708893 bytes console# dir Directory of flash: File Name Permission Size Data Size Modified Flash ------------------- ---------- ---------- -------------------- tmp rw 524288 104 01-Jan-2010 05:35:04 image-1 rw 10485760 10485760 01-Jan-2010 06:10:23 image-2 rw 10485760 10485760 01-Jan-2010 05:43:54 dhcpsn.prv -- 262144 -- 01-Jan-2010 05:25:07 sshkeys.prv -- 262144 -- 04-Jan-2010 06:05:00 syslog1.sys r- 524288 -- 01-Jan-2010 05:57:00 syslog2.sys r- 524288 -- 01-Jan-2010 05:57:00 directry.prv -- 262144 -- 01-Jan-2010 05:25:07 startup-config rw 786432 1081 01-Jan-2010 10:05:34 Total size of flash: 66322432 bytes Free size of flash: 42205184 bytesConfiguration/Image File Commands 135 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY console# more The more Privileged EXEC mode command displays a file. Syntax more url Parameters url—Specifies the location URL or reserved keyword of the source file to be displayed. (Length: 1–160 characters). The following table displays options for the URL parameter: Command Mode Privileged EXEC mode User Guidelines Files are displayed in ASCII format, except for the images, which are displayed in a hexadecimal format. *.prv files cannot be displayed. Example The following example displays the running configuration file contents. Keyword Source or Destination flash:// Source or destination URL for flash memory. If a URL is specified without a prefix, this is the default URL. running-config Current running configuration file. startup-config Startup configuration file. mirror-config Mirrored configuration file. usb: Universal Serial Bus (USB) File System136 Configuration/Image File Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY console# more running-config no spanning-tree interface range gi1/0/1-48 speed 1000 exit no lldp run line console exec-timeout 0 exit cd Use the cd Privileged EXEC mode command to change the current directory. cd new-directory Parameters new-directory—The new directory. The new directory path may be specificed as either a Full Clarified Path or a Relative Path. Command Mode Privileged EXEC mode User Guidelines When command cd changes the current file system, the current directory of the previous file system is saved and when the command specifying only the file system (for example, cd usb:) sets the file system as current, the current directory is restored. Example console cd usb://private/conf console pwd usb://private/conf console cd .. console pwd usb://private console# cd flash:Configuration/Image File Commands 137 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY console pwd flash:// console cd usb: console pwd usb://private console# cd flash:// console pwd flash:\\ console cd usb:// console pwd usb:// rename The rename Privileged EXEC mode command renames a file. Syntax rename url new-url Parameters • url—Specifies the file location URL. (Length: 1–160 characters) • new-url—Specifies the file’s new URL. (Length: 1–160 characters) The following table displays options for the URL parameter: Command Mode Privileged EXEC mode User Guidelines *.sys and *.prv files cannot be renamed. Keyword Source or Destination flash:// URL for flash memory. If a URL is specified without a prefix, this is the default URL. usb: Universal Serial Bus (USB) File System WORD Specify URL prefixes.138 Configuration/Image File Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example renames the configuration file. Console# rename configuration.bak m-config.bak boot system The boot system Privileged EXEC mode command specifies the active system image file that is loaded by the device at startup. Syntax boot system { image-1 | image-2 } [switch number | all] Parameters • switch number—Specifies the unit number. If unspecified, defaults to the master unit number. • image-1—Specifies that image-1 is loaded as the system image during the next device startup. • image-2—Specifies that image-2 is loaded as the system image during the next device startup. Default Configuration This command has no default configuration. The default unit number is the master unit number. Command Mode Privileged EXEC mode User Guidelines Use the show bootvar command to determine which image is the active image.Configuration/Image File Commands 139 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example specifies that image-1 is the active system image file loaded by the device at startup. Console# boot system image-1 show running-config The show running-config Privileged EXEC mode command displays the current running configuration file contents. Syntax show running-config Parameters This command has no arguments or keywords. Command Mode Privileged EXEC mode Example The following example displays the running configuration file contents. Console# show running-config no spanning-tree interface range gi1/0/1-48 speed 1000 exit no lldp run interface vlan 1 ip address 1.1.1.1 255.0.0.0 exit line console exec-timeout 0 exit console#140 Configuration/Image File Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show startup-config The show startup-config Privileged EXEC mode command displays the startup configuration file contents. Syntax show startup-config Command Mode Privileged EXEC mode Example The following example displays the startup configuration file contents. Console# show startup-config no spanning-tree interface range gi1/0/1-48 speed 1000 exit no lldp run interface vlan 1 ip address 1.1.1.1 255.0.0.0 exit line console exec-timeout 0 exit console# show bootvar The show bootvar EXEC mode command displays the active system image file that is loaded by the device at startup. Syntax show bootvar [unit unit]Configuration/Image File Commands 141 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters unit unit—Specifies the unit number. Command Mode EXEC mode Example The following example displays the active system image file that is loaded by the device at startup. Console# show bootvar Unit ---- 1 Image ----- 1 Filename -------- file1 Version ------- 3.1.31 Date -------------------- 23-Jul-2002 17:34:19 Status ----------- Active 1 2 file2 3.2.19 22-Jan-2003 19:22:32 Not active* 2 1 file1 3.1.31 23-Jul-2002 17:34:19 Not active 2 2 file2 3.2.19 22-Jan-2003 19:22:32 Active "*": Designates that the image was selected for the next boot.142 Configuration/Image File Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Configuration_Image.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYAuto-Update and Auto-Configuration 143 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Auto-Update.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 7 Auto-Update and AutoConfiguration boot host auto-config Use the boot host auto-config Global Configuration mode command to enable the support of auto configuration via DHCP. Use the no form of this command to disable DHCP auto configuration. Syntax boot host auto-config no boot host auto-config Parameters This command has no arguments or key words. Command Mode Global Configuration mode Default Configuration Enabled by default. boot host auto-update Use the boot host auto-update Global Configuration mode command to enable the support of auto updated via DHCP. Use the no form of this command to disable DHCP auto configuration.144 Auto-Update and Auto-Configuration FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Auto-Update.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax boot host auto-update no boot host auto-update Parameters This command has no arguments or key words. Command Mode Global Configuration mode Default Configuration Enabled by default. boot host dhcp Use the boot host dhcp Global Configuration mode command to force the mechanism used to download a configuration file at the next system startup. Use the no form of this command to restore the host configuration file to the default. Syntax boot host dhcp no boot host dhcp Parameters This command has no arguments or key words. Command Mode Global Configuration mode User Guidelines Configuring boot host dhcp does not take effect until the next reboot.Auto-Update and Auto-Configuration 145 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Auto-Update.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY boot host auto-save Use the boot host auto-save Global Configuration mode command to enable automatic saving Running in Startup after download. Use the no form of this command restore default behavior. Syntax boot host auto-save no boot host auto-save Parameters This command has no arguments or key words. Command Mode Global Configuration mode Default Configuration Disable show boot Use the show boot Privilege EXEC mode command to show the status of the IP DHCP Auto Config process. Syntax show boot Parameters This command has no keywords or arguments. Command Mode Privilege EXEC mode Examples console# show boot146 Auto-Update and Auto-Configuration FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Auto-Update.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Auto Config ----------- Config Download via DHCP: enable Next Boot Config Download via DHCP: force Auto Config State: Finished TFTP Server IP address: 1.2.20.2 Configuration filename: /config/configfile1.cfg Auto Update ----------- Image Download via DHCP: enabled console# show boot Auto Config ----------- Config Download via DHCP: enable Next Boot Config Download via DHCP: default Auto Config State: Opening -config file Auto Update ------------- Image Download via DHCP: enabled Example 3. console# show boot Auto Config ----------- Config Download via DHCP: enable Next Boot Config Download via DHCP: default Auto Config State: Downloading configuration file Auto Update -----------Auto-Update and Auto-Configuration 147 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Auto-Update.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Image Download via DHCP: enabled console# show boot Auto Config ----------- Config Download via DHCP: enable Next Boot Config Download via DHCP: default Auto Config State: Searching hostname in indirect configuration file Auto Update ----------- Image Download via DHCP: enabled console# show boot Auto Config ----------- Config Download via DHCP: enable Next Boot Config Download via DHCP: default Auto Config State: Quit – failed all steps of finding existing configuration file Auto Update ----------- Image Download via DHCP: enabled console# show boot Auto Config ----------- Config Download via DHCP: enable Next Boot Config Download via DHCP: default Auto Update ----------- Image Download via DHCP: enabled Auto Update State: Downloaded indirect image file148 Auto-Update and Auto-Configuration FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Auto-Update.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY console# show boot Auto Config ----------- Config Download via DHCP: enable Next Boot Config Download via DHCP: default Auto Update ----------- Image Download via DHCP: enabled Auto Update State: Downloading image file console# show boot Auto Config ----------- Config Download via DHCP: enable Next Boot Config Download via DHCP: default Auto Config State: Finished TFTP Server IP address: 1.2.20.2 Configuration filename: /config/configfile1.cfg Auto Update ----------- Image Download via DHCP: enabled Auto Update State: Downloading image file ip dhcp tftp-server ip addr Use the ip dhcp tftp-server ip addr Global Configuration mode command to set the TFTP server’s IP address, used by a switch when it has not been received from the DHCP server. Use the no form of this command to remove the address. Syntax ip dhcp tftp-server ip addr ip-addr no ip dhcp tftp-server ip-addrAuto-Update and Auto-Configuration 149 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Auto-Update.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters ip-addr IP—Address of TFTP server Default Configuration No IP address Command Mode Global Configuration mode ip dhcp tftp-server file Use the ip dhcp tftp-server file Global Configuration mode command to set the full file name on the TFTP server by a switch when it has not been received from the DHCP server. Use the no form of this command to remove the name. Syntax ip dhcp tftp-server file file-path no ip dhcp tftp-server file Parameters file-path—full file name on TFTP server Default Configuration No file name Command Mode Global Configuration mode show ip dhcp tftp-server Use the show ip dhcp tftp-server EXEC mode command to display information about the TFTP server. Syntax show ip dhcp tftp-server150 Auto-Update and Auto-Configuration FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Auto-Update.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode EXEC Example console# show ip dhcp tftp server tftp server address active 1.1.1.1 from sname manual 2.2.2.2 file path on tftp server active conf/conf-file from option 67Management ACL Commands 151 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Management_ACL.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 8 Management ACL Commands management access-list The management access-list Global Configuration mode command configures a management access list and enters the Management Access-List Configuration command mode. Use the no form of this command to delete an access list. Syntax management access-list name no management access-list name Parameters name—Specifies the access list name. (Length: 1–32 characters) Command Mode Global Configuration mode User Guidelines Use this command to configure a management access list. This command enters the Management Access-List Configuration mode, where the denied or permitted access conditions are defined with the deny and permit commands. If no match criteria are defined, the default value is deny. When re-entering the access-list context, the new rules are entered at the end of the access list. Use the management access-class command to select the active access list. The active management list cannot be updated or removed.152 Management ACL Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Management_ACL.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY For IPv6 management traffic that is tunneled in IPv4 packets, the management ACL is applied first on the external IPv4 header (rules with service field are ignored), and then again on the inner IPv6 header. Example The following example creates a management access list called mlist, configures management gigabitethernet interfaces 1/0/1 and 1/0/9, and makes the new access list the active list. Console(config)# management access-list mlist Console(config-macl)# permit gi1/0/1 Console(config-macl)# permit gi1/0/9 Console(config-macl)# exit Console(config)# management access-class mlist The following example creates a management access list called ‘mlist’, configures all interfaces to be management interfaces except gigabitethernet interfaces 1/0/1 and 1/0/9, and makes the new access list the active list. Console(config)# management access-list mlist Console(config-macl)# deny gi1/0/1 Console(config-macl)# deny gi1/0/9 Console(config-macl)# permit Console(config-macl)# exit Console(config)# management access-class mlist permit (Management) The permit Management Access-List Configuration mode command sets conditions for the management access list. Syntax permit [interface-id] [service service] permit ip-source {ipv4-address | ipv6-address/ipv6-prefix-length} [mask {mask | prefix-length}] [interface-id] [service service]Management ACL Commands 153 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Management_ACL.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • interface-id:—Specify an interface ID. The interface ID can be one of the following types: Ethernet port, Port-channel or VLAN • service service — Specifies the service type. Possible values are: Telnet, SSH, HTTP, HTTPS and SNMP. • ipv4-address— Specifies the source IPv4 address. • ipv6-address/ipv6-prefix-length— Specifies the source IPv6 address and source IPv6 address prefix length. The prefix length must be preceded by a forward slash (/). The parameter is optional. • mask mask — Specifies the source IPv4 address network mask. This parameter is relevant only to IPv4 addresses. • mask prefix-length — Specifies the number of bits that comprise the source IPv4 address prefix. The prefix length must be preceded by a forward slash (/). This parameter is relevant only to IPv4 addresses. (Range: 0–32) Command Mode Management Access-List Configuration mode User Guidelines Rules with ethernet, VLAN, and port-channel parameters are valid only if an IP address is defined on the appropriate interface. Example The following example permits all ports in the access list called mlist Console(config)# management access-list mlist Console(config-macl)# permit deny (Management) The deny Management Access-List Configuration mode command sets conditions for the management access list.154 Management ACL Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Management_ACL.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax deny [interface-id] [service service] deny ip-source {ipv4-address | ipv6-address/ipv6-prefix-length} [mask {mask | prefix-length}] [interface-id] [service service] Parameters • interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port, Port-channel or VLAN • service service—Specifies the service type. Possible values are: Telnet, SSH, HTTP, HTTPS and SNMP. • ipv4-address—Specifies the source IPv4 address. • ipv6-address/ipv6-prefix-length—Specifies the source IPv6 address and source IPv6 address prefix length. The prefix length must be preceded by a forward slash (/). The parameter is optional. • mask mask—Specifies the source IPv4 address network mask. The parameter is relevant only to IPv4 addresses. • mask prefix-length—Specifies the number of bits that comprise the source IPv4 address prefix. The prefix length must be preceded by a forward slash (/). The parameter is relevant only to IPv4 addresses. (Range: 0–32) Command Mode Management Access-List Configuration mode User Guidelines Rules with ethernet, VLAN, and port-channel parameters are valid only if an IP address is defined on the appropriate interface. Example The following example denies all ports in the access list called mlist. Console(config)# management access-list mlist Console(config-macl)# denyManagement ACL Commands 155 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Management_ACL.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY management access-class The management access-class Global Configuration mode command restricts management connections by defining the active management access list. To disable management connection restrictions, use the no form of this command. Syntax management access-class {console-only | name} no management access-class Parameters • console-only—Specifies that the device can be managed only from the console. • name—Specifies the access list name to be used. (Length: 1–32 characters) Default Configuration The default configuration is no management connection restrictions. Command Mode Global Configuration mode Example The following example defines an access list called mlist as the active management access list. Console(config)# management access-class mlist show management access-list The show management access-list Privileged EXEC mode command displays management access lists. Syntax show management access-list [name]156 Management ACL Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Management_ACL.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters name—Specifies the name of a management access list to be displayed. (Length: 1–32 characters) Command Mode Privileged EXEC mode Example The following example displays the mlist management access list. Console# show management access-list mlist console-only ------------ deny ! (Note: all other access implicitly denied) mlist ----- permit gi1/0/1 permit gi1/0/9 ! (Note: all other access implicitly denied) console# show management access-class The show management access-class Privileged EXEC mode command displays information about the active management access list. Syntax show management access-class Command Mode Privileged EXEC modeManagement ACL Commands 157 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Management_ACL.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the active management access list information. Console# show management access-class Management access-class is enabled, using access list mlist158 Management ACL Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Management_ACL.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYSNMP Commands 159 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 9 SNMP Commands snmp-server Use the snmp-server server Global Configuration mode command to enable the device to be configured by SNMP. Use the no form of this command to disable this function. Syntax snmp-server server no snmp-server server Parameters This command has no arguments or keywords. Default Enabled Command Mode Global Configuration mode Example snmp-server server ====================== console(config)# snmp-server server snmp-server community Use the snmp-server community Global Configuration mode command to set up the community access string to permit access to the Simple Network 160 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Management Protocol command. Use the no form of this command to remove the specified community string. Syntax snmp-server community string [view view-name] [ro | rw | su] {ipv4- address| ipv6-address} [mask | prefix-length] [type router | oob] snmp-server community-group string group-name [ipv4-address| ipv6- address] [mask | prefix-length] [type router | oob] no snmp-server community string [ipv4-address| ipv6-address] Parameters • string—Community string that acts like a password and permits access to the SNMP protocol. (Range: 1–20 characters) • ro—Specifies read-only access (default) • rw—Specifies read-write access • su—Specifies SNMP administrator access • view view-name—Specifies the name of a view to be configured using the command snmp-server view (no specific order of the command configurations is imposed on the user). The view defines the objects available to the community. It is not relevant for su, which has access to the whole MIB. If unspecified, all the objects, except the community-table and SNMPv3 user and access tables, are available. (Range: 1–30 characters) • ipv4-address—Management station IPv4 address. The default is all IP addresses. • ipv6-address—Management station IPv4 address. The default is all IP addresses. • mask—Specifies the mask of the IPv4 address. This is not a network mask, but rather a mask that defines which bits of the packet’s source address are compared to the configured IP address. If unspecified, it defaults to 255.255.255.255. The command returns an error if the mask is specified without an IPv4 address. • prefix-length—Specifies the number of bits that comprise the IPv4 address prefix. If unspecified, it defaults to 32. The command returns an error if the prefix-length is specified without an IPv4 address.SNMP Commands 161 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • group-name—Specifies the name of a group that should be configured using the command snmp-server group with v1 or v2 parameter (no specific order of the two command configurations is imposed on the user). The group defines the objects available to the community. (Range: 1–30 characters) • type router—Specifies that SNMP requests for duplicate tables configure the router tables. This is the default. • type oob—Specifies that SNMP requests for duplicate tables configure the oob tables. Default No community is defined Command Mode Global Configuration mode User Guidelines You can’t specify view-name for su, which has access to the whole MIB. You can use the view-name to restrict the access rights of a community string. The logical key of the command is the pair (community, ip-address). If ipaddress is omitted then the key is (community, All-Ips). By specifying the view-name parameter, the software: • Generates an internal security-name. • Maps the internal security-name for SNMPv1 and SNMPv2 security models to an internal group-name. • Maps the internal group-name for SNMPv1 and SNMPv2 security models to view-name (read-view and notify-view always, and for rw for write-view also), You can use the group-name to restrict the access rights of a community string. By specifying the group-name parameter the software: • Generates an internal security-name. • Maps the internal security-name for SNMPv1 and SNMPv2 security models to the group-name.162 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY The snmp-server community-group command and snmp-server user command for v1 and v2 are equivalent. You should use the snmp-server community-group command when you want to configure the ipv4-address| ipv6-address management addresses. The Type keyword is used for a different purpose. Therefore, when defining an SNMP community, the administrator must indicate which tables are being configured. If Type is router, it means that the device's tables are being configured. Example snmp-server community ========================== console(config)# snmp-server community abcd su 1.1.1.121 mask 255.0.0.0 console(config)# snmp-server community-group tom abcd 1.1.1.122 prefix 8 snmp-server view The snmp-server view Global Configuration mode command creates or updates a Simple Network Management Protocol (SNMP) server view entry. Use the no form of this command to remove an SNMP server view entry. Syntax snmp-server view view-name oid-tree {included | excluded} no snmp-server view view-name [oid-tree] Parameters • view-name—Specifies the label for the view record that is being created or updated. The name is used to reference the record. (Length: 1–30 characters) • oid-tree—Specifies the ASN.1 subtree object identifier to be included or excluded from the view. To identify the subtree, specify a text string consisting of numbers, such as 1.3.6.2.4, or a word, such as System. Replace a single sub-identifier with the asterisk (*) wildcard to specify a subtree family; for example 1.3.*.4. • included—Specifies that the view type is included.SNMP Commands 163 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • excluded—Specifies that the view type is excluded. Default Configuration Default and DefaultSuper are the default view names. Command Mode Global Configuration mode User Guidelines This command can be entered multiple times for the same view record. The command logical key is the pair (view-name, oid-tree). The number of views is limited to 64. Default and DefaultSuper views are reserved for internal software use and cannot be deleted or modified. Example The following example creates a view that includes all objects in the MIB-II system group except for sysServices (System 7) and all objects for interface 1 in the MIB-II interface group. Console(config)# snmp-server view user-view system included Console(config)# snmp-server view user-view system.7 excluded Console(config)# snmp-server view user-view ifEntry.*.1 included snmp-server group The snmp-server group Global Configuration mode command configures a new Simple Network Management Protocol (SNMP) group or a table that maps SNMP users to SNMP views. Use the no form of this command, remove a specified SNMP group. Syntax snmp-server group groupname {v1 | v2 | v3 {noauth | auth | priv} [notify notifyview]} [read readview] [write writeview]164 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY no snmp-server group groupname {v1 | v2 | v3 [noauth | auth | priv]} [context name] Parameters • groupname—Specifies the group name. (Length: 1–30 characters) • v1—Specifies the SNMP Version 1 security model. • v2—Specifies the SNMP Version 2 security model. • v3—Specifies the SNMP Version 3 security model. • noauth—Specifies no packet authentication. Applicable only to the SNMP Version 3 security model. • auth—Specifies packet authentication without encryption. Applicable only to the SNMP Version 3 security model. • priv—Specifies packet authentication with encryption. Applicable only to the SNMP Version 3 security model. • notify notifyview—Specifies the view name that enables specifying an inform or a trap. Applicable only to the SNMP Version 3 security model. (Length: 1–30 characters) • read readview—Specifies the view name that enables viewing only the agent contents. (Length: 1–30 characters) • write writeview—Specifies the view name that enables entering data and configuring the agent contents. (Length: 1–30 characters) Default Configuration No group entry exists. If notifyview is not specified, nothing is defined for the notify view. If readview is not specified, all objects except for the community-table and SNMPv3 user and access tables are available. If writeview is not specified, nothing is defined for the write view. Command Mode Global Configuration modeSNMP Commands 165 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines The command logical key is (groupname, snmp-version, security-level). For snmp-version v1/v2 the security-level is always noauth. The Router context is translated to "" context in the MIB. Example The following example attaches a group called user-group to SNMPv3 and assigns to the group the privacy security level and read access rights to a view called user-view. Console(config)# snmp-server group user-group v3 priv read userview snmp-server user Use the snmp-server user Global Configuration mode command to configure a new SNMP Version 3 user. Use the no form of the command to remove a user. Syntax snmp-server user username groupname {v1 | v2c | [remote host] v3 [encrypted] [auth {md5 | sha} auth-password]} no snmp-server user username [remote host] Parameters • username—The name of the user on the host that connects to the agent. (Range: Up to 20 characters) • groupname—The name of the group to which the user belongs. The group should be configured using the command snmp-server group with v3 parameters (no specific order of the 2 command configurations is imposed on the user). (Range: Up to 30 characters) • remote host—IP address of the remote SNMP host. • v1—Specifies that v1 is to be used. • v2c—Specifies that v2c is to be used.166 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • v3—Specifies that v3 is to be used. • encrypted—Specifies whether the password appears in encrypted format. • auth—Specifies which authentication level is to be used. • md5—Specifies the HMAC-MD5-96 authentication level. • Sha—Specifies the HMAC-SHA-96 authentication level. • auth-password—Specifies the authentication password. Parameters Range engineid-string5 - 32 characters. auth-passwordUp to 32 characters. Default No group entry exists. Command Mode Global configuration User Guidelines If auth md5 or auth sha is specified, both authentication and privacy are enabled for the user. When you enter a show running-config command, you do not see a line for this user. To see if this user has been added to the configuration, type the show snmp user command. An SNMP EngineID should be defined in order to add users to the device. Changing or removing the value of snmpEngineID deletes the SNMPv3 users’ database. The logical key of the command is Username. Configuring a remote host is required in order to send informs to that host. A configured remote host is also able to manage the device (besides getting the informs) To configure a remote user, specify the IP address for the remote SNMP agent of the device where the user resides. Also, before you configure remote users for a particular agent, configure the SNMP engine ID, using the snmp-server engineID remote command. The remote agent's SNMP engine ID is needed when computing the authentication and privacy digests from the password. If SNMP Commands 167 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY the remote engine ID is not configured first, the configuration command fails. Example snmp-server user ==================== console(config)# snmp-server user tom acbd v1 console(config)# snmp-server user tom acbd v2c console(config)# snmp-server engineid local default The engine-id must be unique within your administrative domain. Do you wish to continue? [Y/N] y The SNMPv3 database will be erased. Do you wish to continue? [Y/N] y console(config)# snmp-server user tom acbd v3 snmp-server filter The snmp-server filter Global Configuration mode command creates or updates a Simple Network Management Protocol (SNMP) server filter entry. Use the no form of this command to remove the specified SNMP server filter entry. Syntax snmp-server filter filter-name oid-tree {included | excluded} no snmp-server filter filter-name [oid-tree] Parameters • filter-name—Specifies the label for the filter record that is being updated or created. The name is used to reference the record. (Length: 1–30 characters)168 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • oid-tree—Specifies the ASN.1 subtree object identifier to be included or excluded from the view. To identify the subtree, specify a text string consisting of numbers, such as 1.3.6.2.4, or a word, such as System. Replace a single sub-identifier with the asterisk (*) wildcard to specify a subtree family; for example, 1.3.*.4. • included—Specifies that the filter type is included. • excluded—Specifies that the filter type is excluded. Default Configuration No view entry exists. Command Mode Global Configuration mode User Guidelines This command can be entered multiple times for the same filter record. If an object identifier is included in two or more lines, later lines take precedence. The command's logical key is the pair (filter-name, oid-tree). Example The following example creates a filter that includes all objects in the MIB-II system group except for sysServices (System 7) and all objects for interface 1 in the MIB-II interfaces group. Console(config)# snmp-server filter filter-name system included Console(config)# snmp-server filter filter-name system.7 excluded Console(config)# snmp-server filter filter-name ifEntry.*.1 included snmp-server host Use the snmp-server host Global Configuration mode command to specify the recipient of a Simple Network Management Protocol notification operation. Use the no form of this command to remove the specified host.SNMP Commands 169 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax snmp-server host { ipv4-address | ipv6-address| hostname} [traps | informs] [version {1 | 2c | 3 [auth | noauth | priv]}] community-string [udp-port port] [filter filtername] [timeout seconds] [retries retries] no snmp-server host { ipv4-address | ipv6-address| hostname} [traps | informs] [version {1 | 2c | 3}] Parameters • pv4-address—IPv4 address of the host (the targeted recipient). • ipv6-address—Pv6 address of the host (the targeted recipient). When the IPv6 address is a Link Local address (IPv6Z address), the outgoing interface name must be specified. Refer to the User Guidelines for the interface name syntax. • hostname—Hostname of the host. (Range: 1–158 characters. Maximum label size: 63) • trap—Sends SNMP traps to this host (default). • informs—Sends SNMP informs to this host. Not applicable to SNMPv1. • 1—SNMPv1 traps are used. • 2c—SNMPv2 traps are used • 3—SNMPv2 traps are used • community-string—Password-like community string sent with the notification operation. (Range: 1–20 characters) • noauth—Specifies no authentication of a packet. • auth—Specifies authentication of a packet without encrypting it. • priv—Specifies authentication of a packet with encryption. • udp-port port—UDP port of the host to use. The default is 162. (Range: 1–65535) • filter filtername—A string that is the name of the filter that defines the filter for this host. If unspecified, nothing is filtered. The filter should be defined using the command snmp-server filter (no specific order of the command configurations is imposed on the user). (Range: Up to 30 characters)170 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • timeout seconds—Number of seconds to wait for an acknowledgment before resending informs. The default is 15 seconds. The parameter is relevant only for informs. (Range: 1–300) • retries retries—Maximum number of times to resend an inform request, when a response is not received for a generated message. The default is 3. The parameter is relevant only for informs. (Range: 0–255) Command Mode Global Configuration mode User Guidelines The logical key of the command is the pair (ip-address/hostname, traps/informs, version). When configuring snmp v1 or v2 notifications recipient the software would automatically generate a notification view for that recipient for all the MIB. (.For SNMPv3 the software doesn’t automatically create a user nor a notify view. Use the commands snmp-server user, snmp-server group and snmpserver view in Global Configuration mode to create a user, a group or a notify group respectively. The format of an IPv6Z address is: % interface-name = vlan | ch | isatap | | 0 integer = | decimal-number = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 physical-port-name = Designated port number, for example 1/0/16 If the egress interface is not specified, the default interface is selected. Specifying interface zone=0 is equal to not defining an egress interface. Example The following defines a host at the IP address displayed. console(config)# snmp-server host 1.1.1.121 abcSNMP Commands 171 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY snmp-server engineID local The snmp-server engineID local Global Configuration mode command specifies the Simple Network Management Protocol (SNMP) engineID on the local device. Use the no form of this command to remove the configured engine ID. Syntax snmp-server engineID local {engineid-string | default} no snmp-server engineID local Parameters • engineid-string—Specifies a concatenated hexadecimal character string identifying the engine ID. Each byte in a hexadecimal character string is two hexadecimal digits. Bytes are separated by a period or colon. If an odd number of hexadecimal digits are entered, the system automatically prefixes the digit 0 to the string. (Length: 5–32 characters, 9–64 hexadecimal digits) • default—Specifies that the engine ID is created automatically based on the device MAC address. Default Configuration The engine ID is not configured. If SNMPv3 is enabled using this command, and the default is specified, the default engine ID is defined per standard as: • First 4 octets: First bit = 1, the rest is IANA Enterprise number = 674. • Fifth octet: Set to 3 to indicate the MAC address that follows. • Last 6 octets: The device MAC address. Command Mode Global Configuration mode User Guidelines To use SNMPv3, specify an engine ID for the device. Any ID can be specified or use a default string, which is generated using the device MAC address.172 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY As the EngineID should be unique within an administrative domain, the following guidelines are recommended: • For standalone devices, use the default keyword to configure the Engine ID. • For stackable systems, configure an EngineID, and verify that it is unique within the administrative domain. Changing or removing the value of snmpEngineID deletes the SNMPv3 users database. The SNMP EngineID cannot be all 0x0 or all 0xF or 0x000000001 Example The following example enables SNMPv3 on the device and sets the device local engine ID to the default value. Console(config)# snmp-server engineID local default snmp-server engineID remote To specify the Simple Network Management Protocol (SNMP) engine ID of a remote SNMP device, use the snmp-server engineID remote Global Configuration mode command. Use the no form of this command to remove the configured engine ID. Syntax snmp-server engineID remote {ipv4-ip-address | ipv6 address} engineidstring no snmp-server engineID remote {ipv4-ip-address | ipv6 address} Parameters • ipv4-ip-address | ipv6 address—Pv4 or IPv6 address of the remote device • engineid-string—The character string that identifies the engine ID. The engine ID is a concatenated hexadecimal string. Each byte in hexadecimal character strings is two hexadecimal digits. Each byte can be separated by SNMP Commands 173 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY a period or colon. If the user enters an odd number of hexadecimal digits, the system automatically prefixes the hexadecimal string with a zero. (Range: engineid-string5–32 characters. 9–64 hexadecimal digits) Default Configuration The EngineID is not configured. Command Mode Global Configuration mode User Guidelines A remote engine ID is required when an SNMP version 3 inform is configured. The remote engine ID is used to compute the security digest for authenticating and encrypting packets sent to a user on the remote host. snmp-server enable traps Use the snmp-server enable traps Global Configuration mode command to enable the device to send SNMP traps. Use the no form of the command to disable SNMP traps. Syntax snmp-server enable traps no snmp-server enable traps Default Configuration SNMP traps are enabled. Command Mode Global Configuration mode Example The following example enables SNMP traps. Console(config)# snmp-server enable traps174 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY snmp-server trap authentication Use the snmp-server trap authentication Global Configuration mode command to enable the device to send SNMP traps when authentication fails. Use the no form of this command to disable SNMP failed authentication traps. Syntax snmp-server trap authentication no snmp-server trap authentication Default Configuration SNMP failed authentication traps are enabled. Command Mode Global Configuration mode Example The following example enables SNMP failed authentication traps. Console(config)# snmp-server trap authentication snmp-server contact Use the snmp-server contact Global Configuration mode command to configure the system contact (sysContact) string. Use the no form of the command to remove the system contact information. Syntax snmp-server contact text no snmp-server contact Parameters text—Specifies the string describing system contact information. (Length: 1–160 characters)SNMP Commands 175 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode Example The following example configures the system contact point called Technical_Support. Console(config)# snmp-server contact Technical_Support snmp-server location Use the snmp-server location Global Configuration mode command to configure the system location string. Use the no form of this command to remove the location string. Syntax snmp-server location text no snmp-server location Parameters text—Specifies a string describing system location information. (Length: 1–160 characters) Command Mode Global Configuration mode Example The following example defines the device location as New_York. Console(config)# snmp-server location New_York snmp-server set Use the snmp-server set Global Configuration mode command to define the SNMP MIB value.176 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax snmp-server set variable-name name value [name2 value2 ...] Parameters • variable-name—Specifies the SNMP MIB variable name, which must be a valid string. • name value—Specifies a list of name and value pairs. Each name and value must be a valid string. In the case of scalar MIBs, there is only a single name-value pair. In the case of an entry in a table, there is at least one name-value pair, followed by one or more fields. Command Mode Global Configuration mode User Guidelines Although the CLI can set any required configuration, there might be a situation where an SNMP user sets a MIB variable that does not have an equivalent command. To generate configuration files that support those situations, use the snmp-server set command. Example The following example configures the scalar MIB sysName with the value TechSupp. Console(config)# snmp-server set sysName sysname TechSupp show snmp Use the show snmp Privileged EXEC mode command to display the SNMP status. Syntax show snmp Command Mode Privileged EXEC modeSNMP Commands 177 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the SNMP communications status. Console# show snmp SNMP is enabled CommunityString -------------- public private private Community-Access ---------------- read only read write su View name ------------ user-view Default DefaultSuper IP Address ---------- All 172.16.1.1/1 0 172.16.1.1 Type ---- Router Router Router Communitystring -------------- public Group name ---------- user-group IP address ---------- All Type ------ Router Traps are enabled. Authentication trap is enabled. Version 1,2 notifications Target Address -------------- 192.122.173.42 192.122.173.42 Type ---- Trap Info rm Community --------- public public Version ------ 2 2 UDP Port --- 162 162 Filter name ------ TO Sec --- 15 15 Retries ------- 3 3 Version 3 notifications Target Address -------------- 192.122.173.42 Type ---- Info rm Username -------- Bob Security Level ------ Priv UDP Port --- 162 Filter name ----- TO Sec --- 15 Retries ------- 3 System Contact: Robert System Location: Marketing178 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes the significant fields shown in the display. show snmp engineID Use the show snmp engineID Privileged EXEC mode command to display the local Simple Network Management Protocol (SNMP) engine ID. Syntax show snmp engineID Command Mode Privileged EXEC mode Example The following example displays the SNMP engine ID. Console # show snmp engineID Local SNMP engineID: 08009009020C0B099C075878 #Editor: If snmp-server engineID remote command is supported add the following line IP address Remote SNMP engineID ----------- ------------------------------- 172.16.1.1 08009009020C0B099C075879 Field Description Community-string The community access string permitting access to the SNMP protocol. Community-access The access type—read-only, read-write, super access. IP Address The management station IP Address. Trap-Rec-Address The targeted recipient. Trap-Rec-Community The statistics sent with the notification operation. Version The SNMP version (1 or 2) for the sent trap.SNMP Commands 179 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show snmp views Use the show snmp views Privileged EXEC mode command to display the configured SNMP views. Syntax show snmp views [viewname] Parameters viewname—Specifies the view name. (Length: 1–30 characters) Command Mode Privileged EXEC mode Example The following example displays the configured SNMP views. show snmp groups Use the show snmp groups Privileged EXEC mode command to display the configured SNMP groups. Syntax show snmp groups [groupname] Parameters groupname—Specifies the group name. (Length: 1–30 characters) Console# show snmp views Name OID Tree Type ---------------- Default Default ---------------------- iso snmpNotificationMIB ---------- Included Excluded180 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Privileged EXEC mode Example The following example displays the configured SNMP groups. The following table describes significant fields shown above. show snmp filters Use the show snmp filters Privileged EXEC mode command to display the configured SNMP filters. Console# show snmp groups Name Security Views ------------- user-group managers-group Model ----- V3 V3 Level ---- priv priv Read ------- Default Default Write ------- "" Default Notify ------- "" "" Field Description Name Group name. Security Model SNMP model in use (v1, v2 or v3). Security Level Packet authentication with encryption. Applicable to SNMP v3 security only. Views Read View name enabling viewing the agent contents. If unspecified, all objects except the communitytable and SNMPv3 user and access tables are available. Write View name enabling data entry and managing the agent contents. Notify View name enabling specifying an inform or a trap.SNMP Commands 181 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show snmp filters [filtername] Parameters filtername—Specifies the filter name. (Length: 1–30 characters) Command Mode Privileged EXEC mode Example The following example displays the configured SNMP filters. show snmp users Use the show snmp users Privileged EXEC mode command to display the configured SNMP users. Syntax show snmp users [username] Parameters username—Specifies the user name. (Length: 1–30 characters) Command Mode Privileged EXEC mode Console# show snmp filters Name OID Tree Type ------------ user-filter user-filter user-filter --------------------- 1.3.6.1.2.1.1 1.3.6.1.2.1.1.7 1.3.6.1.2.1.2.2.1.*.1 --------- Included Excluded Included182 SNMP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\SNMP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the configured SNMP users. Console# show snmp users Name ------ John John Group name ------------ user-group user-group Auth Method ------- md5 md5 Remote ------------------------ 08009009020C0B099C075879RSA and Certificate Commands 183 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 10 RSA and Certificate Commands crypto key generate dsa The crypto key generate dsa Global Configuration mode command generates DSA key pairs. Syntax crypto key generate dsa Default Configuration DSA key pairs do not exist. Command Mode Global Configuration mode User Guidelines DSA keys are generated in pairs - one public DSA key and one private DSA key. If the device already has DSA keys, a warning is displayed with a prompt to replace the existing keys with new keys. This command is not saved in the router configuration. However, the keys generated by this command are saved in the private configuration (which is never displayed to the user or backed up to another device). Example The following example generates DSA key pairs. Console(config)# crypto key generate dsa184 RSA and Certificate Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY crypto key generate rsa The crypto key generate rsa Global Configuration mode command generates RSA key pairs. Syntax crypto key generate rsa Default Configuration RSA key paris do not exist. Command Mode Global Configuration mode User Guidelines RSA keys are generated in pairs - one public RSA key and one private RSA key. If the device already has RSA keys, a warning is displayed with a prompt to replace the existing keys with new keys. This command is not saved in the router configuration; however, the keys generated by this command are saved in the private configuration (which is never displayed to the user or backed up to another device). Example The following example generates RSA key pairs. Console(config)# crypto key generate rsa show crypto key mypubkey The show crypto key mypubkey Privileged EXEC mode command displays the device SSH public keys. Syntax show crypto key mypubkey [rsa | dsa]RSA and Certificate Commands 185 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • rsa—Displays the RSA key. • dsa—Displays the DSA key. Command Mode Privileged EXEC mode Example The following example displays the SSH public RSA keys on the device. Console# show crypto key mypubkey rsa RSA key data: 005C300D 06092A86 4886F70D 01010105 00034B00 30480241 00C5E23B 55D6AB22 04AEF1BA A54028A6 9ACC01C5 129D99E4 64CAB820 847EDAD9 DF0B4E4C 73A05DD2 BD62A8A9 FA603DD2 E2A8A6F8 98F76E28 D58AD221 B583D7A4 71020301 87685768 Fingerprint(Hex): 77:C7:19:85:98:19:27:96:C9:CC:83:C5:78:89:F8:86 Fingerprint(Bubble Babble): yteriuwt jgkljhglk yewiury hdskjfryt gfhkjglk crypto certificate generate The crypto certificate generate Global Configuration mode command generates a self-signed certificate for HTTPS. Syntax crypto certificate number generate [key-generate [length]] [passphrase string] [cn common- name] [ou organization-unit] [or organization] [loc location] [st state] [cu country] [duration days] Parameters • number—Specifies the certificate number. (Range: 1–2) • key-generate—Regenerates SSL RSA key. • length—Specifies the SSL's RSA key length. (Range: 512–2048) • passphrase string—Specifies the passphrase used for exporting the certificate in PKCS12 file format. (Length: 8–96 characters)186 RSA and Certificate Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • cn common-name—Specifies the fully qualified device URL or IP address. (Length: 1–64 characters) • ou organization-unit—Specifies the organization-unit or department name. (Length: 1–64 characters) • or organization—Specifies the organization name. (Length: 1–64 characters) • loc location—Specifies the location or city name. (Length: 1–64 characters) • st state—Specifies the state or province name. (Length: 1–64 characters) • cu country—Specifies the country name. (Length: 2 characters) • duration days—Specifies the number of days a certification is valid. (Range: 30–3650) Default Configuration The default certificate number is 1. The default SSL’s RSA key length is 1024. If passphrase string is not specified, the certificate is not exportable. If cn common-name is not specified, it defaults to the device’s lowest static IPv6 address (when the certificate is generated), or to the device’s lowest static IPv4 address if there is no static IPv6 address, or to 0.0.0.0 if there is no static IP address. If duration days is not specified, it defaults to 365 days. Command Mode Global Configuration mode User Guidelines This command is not saved in the router configuration. However, the certificate and keys generated by this command are saved in the private configuration (which is never displayed to the user or backed up to another device). When exporting a RSA key pair to a PKCS#12 file, the RSA key pair is as secure as the passphrase. Keep the passphrase secure. If the RSA key does not exist, you must use the parameter key-generate.RSA and Certificate Commands 187 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example generates a self-signed certificate for HTTPS. Console# crypto certificate generate key-generate crypto certificate request The crypto certificate request Privileged EXEC mode command generates and displays a certificate request for HTTPS. Syntax crypto certificate number request common-name [ou organization-unit] [or organization] [loc location] [st state] [cu country] Parameters • number—Specifies the certificate number. (Range: 1–2) • common-name—Specifies the device’s fully qualified URL or IP address. (Length: 1–64 characters) • ou organization-unit—Specifies the organization-unit or department name. (Length: 1–64 characters) • or organization—Specifies the organization name. (Length: 1–64 characters) • loc location—Specifies the location or city name. (Length: 1–64 characters) • st state—Specifies the state or province name. (Length: 1–64 characters) • cu country—Specifies the country name. (Length: 2 characters) Command Mode Privileged EXEC mode User Guidelines Use this command to export a certificate request to a Certification Authority. The certificate request is generated in Base64-encoded X.509 format.188 RSA and Certificate Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Before generating a certificate request, first generate a self-signed certificate using the crypto certificate generate Global Configuration mode command to generate the keys. The certificate fields must be re-entered. After receiving the certificate from the Certification Authority, use the crypto certificate import Global Configuration mode command to import the certificate into the device. This certificate replaces the self-signed certificate. Example The following example displays the certificate request for HTTPS. Console# crypto certificate 1 request -----BEGIN CERTIFICATE REQUEST----- MIwTCCASoCAQAwYjELMAkGA1UEBhMCUFAxCzAJBgNVBAgTAkNDMQswCQYDVQQH EwRDEMMAoGA1UEChMDZGxkMQwwCgYDVQQLEwNkbGQxCzAJBgNVBAMTAmxkMRAw DgKoZIhvcNAQkBFgFsMIGfMA0GCSqGSIb3DQEBAQUAA4GNADCBiQKBgQC8ecwQ HdML0831i0fh/F0MV/Kib6Sz5p+3nUUenbfHp/igVPmFM+1nbqTDekb2ymCu6K aKvEbVLF9F2LmM7VPjDBb9bb4jnxkvwW/wzDLvW2rsy5NPmH1QVl+8Ubx3GyCm /oW93BSOFwxwEsP58kf+sPYPy+/8wwmoNtDwIDAQABoB8wHQYJKoZIhvcNAQkH MRDjEyMwgICCAgICAICAgIMA0GCSqGSIb3DQEBBAUAA4GBAGb8UgIx7rB05m+2 m5ZZPhIwl8ARSPXwhVdJexFjbnmvcacqjPG8pIiRV6LkxryGF2bVU3jKEipcZa g+uNpyTkDt3ZVU72pjz/fa8TF0n3 -----END CERTIFICATE REQUEST----- CN= router.gm.com 0= General Motors C= US crypto certificate import The crypto certificate import Global Configuration mode command imports a certificate signed by a Certification Authority for HTTPS. Syntax crypto certificate number importRSA and Certificate Commands 189 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters number—Specifies the certificate number. (Range: 1–2) Command Mode Global Configuration mode User Guidelines To end the session, use a blank line. The imported certificate must be based on a certificate request created by the crypto certificate request privileged EXEC command. If the public key found in the certificate does not match the device's SSL RSA key, the command fails. This command is not saved in the router configuration. However, the certificate imported by this command is saved in the private configuration (which is never displayed to the user or backed up to another device). Example The following example imports a certificate signed by Certification Authority for HTTPS. Console(config)# crypto certificate 1 import -----BEGIN CERTIFICATE----- dHmUgUm9vdCBDZXJ0aWZpZXIwXDANBgkqhkiG9w0BAQEFAANLADBIAkEAp4HS nnH/xQSGA2ffkRBwU2XIxb7n8VPsTm1xyJ1t11a1GaqchfMqqe0kmfhcoHSWr yf1FpD0MWOTgDAwIDAQABo4IBojCCAZ4wEwYJKwYBBAGCNxQCBAYeBABDAEEw CwR0PBAQDAgFGMA8GA1UdEwEB/wQFMAMBAf8wHQYDVR0OBBYEFAf4MT9BRD47 ZvKBAEL9Ggp+6MIIBNgYDVR0fBIIBLTCCASkwgdKggc+ggcyGgclsZGFwOi8v L0VByb3h5JTIwU29mdHdhcmUlMjBSb290JTIwQ2VydGlmaWVyLENOPXNlcnZl -----END CERTIFICATE----- Certificate imported successfully. Issued to: router.gm.com Issued by: www.verisign.com Valid from: 8/9/2003 to 8/9/2004 Subject: CN= router.gm.com, 0= General Motors, C= US190 RSA and Certificate Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Finger print: DC789788 DC88A988 127897BC BB789788 crypto certificate export pkcs12 The crypto certificate export pkcs12 Privileged EXEC mode command exports the certificate and the RSA keys within a PKCS12 file. Syntax crypto certificate number export pkcs12 Parameters number—Specifies the certificate number. (Range: 1–2) Command Mode Privileged EXEC mode User Guidelines The crypto certificate export pkcs12 command creates a PKCS 12 file that contains the certificate and an RSA key pair. The passphrase for the export is determined when the key is generated. The certificate and key pair are exported in a standard PEM-format PKCS12 file. This format can be converted to and from the binary PFX file used by Windows and Linux by using the openssl command-line tool. See an open source OpenSSL user manual (man pkcs12) for more information. Example The following example exports the certificate and the RSA keys within a PKCS12 file. Console# crypto certificate 1 export pkcs12 Bag Attributes localKeyID: 0C 75 81 77 5A 31 53 D1 FF 4E 26 BE 8D 4A FD 8B 22 9F 45 D4 subject=/C=us/ST= /L= /CN= /O= /OU= issuer= /C=us/ST= /L= /CN= /O= /OU= -----BEGIN CERTIFICATE----- MIIBfDCCASYCAQAwDQYJKoZIhvcNAQEEBQAwSTELMAkGA1UEBhMCdXMxCjAIBgNVRSA and Certificate Commands 191 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY BAgTASAxCjAIBgNVBAcTASAxCjAIBgNVBAMTASAxCjAIBgNVBAoTASAxCjAIBgNV BAsTASAwHhcNMDQwMjA3MTU1NDQ4WhcNMDUwMjA2MTU1NDQ4WjBJMQswCQYDVQQG EwJ1czEKMAgGA1UECBMBIDEKMAgGA1UEBxMBIDEKMAgGA1UEAxMBIDEKMAgGA1UE ChMBIDEKMAgGA1UECxMBIDBcMA0GCSqGSIb3DQEBAQUAA0sAMEgCQQCZXP/tk3e/ jrulfZw8q8T2oS5ymrEIes/sRJE8uahTBJqKu1VHqRYJR3VYa/03HSJ741w5MzPI iuWZzrbbuXAxAgMBAAEwDQYJKoZIhvcNAQEEBQADQQBQ+GTLeN1p1kARxI4C1fTU efig3ffZ/tjW5q1t1r5F6zNv/GuXWw7rGzmRyoMXDcYp1TaA4gAIFQCpFGqiSbAx -----END CERTIFICATE----- Bag Attributes localKeyID: 0C 75 81 77 5A 31 53 D1 FF 4E 26 BE 8D 4A FD 8B 22 9F 45 D4 Key Attributes: -----BEGIN RSA PRIVATE KEY----- Proc-Type: 4,ENCRYPTED DEK-Info: DES-EDE3-CBC,085DCBF3A41D2669 dac0m9jqEp1DM50sIDb8Jq1jxW/1P0kqSxuMhc25OdBE/1fPBg9VSvV1ARaYt16W bX67UyJ8t7HHF3AowjcWzElQ5GJgSQ0VemsqsRQzjpCTb090rx+cNwVfIvjoedgQ Mtl5+fKIAcqsfEgEGJNXQ4jEzsXAkwfQLFfgt47O3IpkUn0AxrQzutJDOcC28Uxp raMVTVSlSkJIvaPuXJxdZ279tDMwZffILBfKCJGACT5V5/4WEqDkrF+uuF9/oxm2 5SVL8TvUmXB/3hX4UoaXtxAhuyOdhh1kyyZSpw9BPPR/8bc/wUYERh7+7JXLKHpd ueeu3znfIX4dDeti8B3xYvvE8kGZjxFN1cC3zc3JsD0IVu1LkyiAa93P4LPEvAwG Fw1LqmGiiqw9JM/tzc6kYkZXylFzCrSVf2exP+/tEvM= -----END RSA PRIVATE KEY----- crypto certificate import pkcs12 The crypto certificate import pkcs12 Privileged EXEC mode command imports the certificate and the RSA keys within a PKCS12 file. Syntax crypto certificate number import pkcs12 passphrase Parameters • number—Specifies the certificate number. (Range: 1–2) • passphrase—Specifies the passphrase used to encrypt the PKCS12 file for export. (Length: 8–96 characters)192 RSA and Certificate Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Privileged EXEC mode User Guidelines Use the passphrase that was exported by the crypto certificate export pkcs12 command. NOTE: This passphrase is saved for later exports. Example The following example imports the certificate and the RSA keys within a PKCS12 file. Console# crypto certificate 1 import pkcs12 passphrase Bag Attributes localKeyID: 0C 75 81 77 5A 31 53 D1 FF 4E 26 BE 8D 4A FD 8B 22 9F 45 D4 subject=/C=us/ST= /L= /CN= /O= /OU= issuer= /C=us/ST= /L= /CN= /O= /OU= -----BEGIN CERTIFICATE----- MIIBfDCCASYCAQAwDQYJKoZIhvcNAQEEBQAwSTELMAkGA1UEBhMCdXMxCjAIBgNV BAgTASAxCjAIBgNVBAcTASAxCjAIBgNVBAMTASAxCjAIBgNVBAoTASAxCjAIBgNV BAsTASAwHhcNMDQwMjA3MTU1NDQ4WhcNMDUwMjA2MTU1NDQ4WjBJMQswCQYDVQQG EwJ1czEKMAgGA1UECBMBIDEKMAgGA1UEBxMBIDEKMAgGA1UEAxMBIDEKMAgGA1UE ChMBIDEKMAgGA1UECxMBIDBcMA0GCSqGSIb3DQEBAQUAA0sAMEgCQQCZXP/tk3e/ jrulfZw8q8T2oS5ymrEIes/sRJE8uahTBJqKu1VHqRYJR3VYa/03HSJ741w5MzPI iuWZzrbbuXAxAgMBAAEwDQYJKoZIhvcNAQEEBQADQQBQ+GTLeN1p1kARxI4C1fTU efig3ffZ/tjW5q1t1r5F6zNv/GuXWw7rGzmRyoMXDcYp1TaA4gAIFQCpFGqiSbAx -----END CERTIFICATE----- Bag Attributes localKeyID: 0C 75 81 77 5A 31 53 D1 FF 4E 26 BE 8D 4A FD 8B 22 9F 45 D4 Key Attributes: -----BEGIN RSA PRIVATE KEY----- Proc-Type: 4,ENCRYPTED DEK-Info: DES-EDE3-CBC,085DCBF3A41D2669 dac0m9jqEp1DM50sIDb8Jq1jxW/1P0kqSxuMhc25OdBE/1fPBg9VSvV1ARaYt16W bX67UyJ8t7HHF3AowjcWzElQ5GJgSQ0VemsqsRQzjpCTb090rx+cNwVfIvjoedgQ Mtl5+fKIAcqsfEgEGJNXQ4jEzsXAkwfQLFfgt47O3IpkUn0AxrQzutJDOcC28UxpRSA and Certificate Commands 193 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY raMVTVSlSkJIvaPuXJxdZ279tDMwZffILBfKCJGACT5V5/4WEqDkrF+uuF9/oxm2 5SVL8TvUmXB/3hX4UoaXtxAhuyOdhh1kyyZSpw9BPPR/8bc/wUYERh7+7JXLKHpd ueeu3znfIX4dDeti8B3xYvvE8kGZjxFN1cC3zc3JsD0IVu1LkyiAa93P4LPEvAwG Fw1LqmGiiqw9JM/tzc6kYkZXylFzCrSVf2exP+/tEvM= -----END RSA PRIVATE KEY----- show crypto certificate mycertificate The show crypto certificate mycertificate Privileged EXEC mode command displays the device SSL certificates. Syntax show crypto certificate mycertificate [number] Parameters number—Specifies the certificate number. (Range: 1–2 Command Mode Privileged EXEC mode Example The following example displays SSL certificate # 1 present on the device. Console# show crypto certificate mycertificate 1 -----BEGIN CERTIFICATE----- dHmUgUm9vdCBDZXJ0aWZpZXIwXDANBgkqhkiG9w0BAQEFAANLADBIAkEAp4HS nnH/xQSGA2ffkRBwU2XIxb7n8VPsTm1xyJ1t11a1GaqchfMqqe0kmfhcoHSWr yf1FpD0MWOTgDAwIDAQABo4IBojCCAZ4wEwYJKwYBBAGCNxQCBAYeBABDAEEw CwR0PBAQDAgFGMA8GA1UdEwEB/wQFMAMBAf8wHQYDVR0OBBYEFAf4MT9BRD47 ZvKBAEL9Ggp+6MIIBNgYDVR0fBIIBLTCCASkwgdKggc+ggcyGgclsZGFwOi8v L0VByb3h5JTIwU29mdHdhcmUlMjBSb290JTIwQ2VydGlmaWVyLENOPXNlcnZl -----END CERTIFICATE----- Issued by: www.verisign.com Valid from: 8/9/2003 to 8/9/2004 Subject: CN= router.gm.com, 0= General Motors, C= US194 RSA and Certificate Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RSA_and_Certificates.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Finger print: DC789788 DC88A988 127897BC BB789788Web Server Commands 195 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Web_Server.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 11 Web Server Commands ip http server The ip http server Global Configuration mode command enables configuring and monitoring the device from a web browser. Use the no form of this command to disable this function. Syntax ip http server no ip http server Default Configuration HTTP server is enabled. Command Mode Global Configuration mode196 Web Server Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Web_Server.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables configuring the device from a web browser. Console(config)# ip http server ip http port The ip http port Global Configuration mode command specifies the TCP port used by the web browser interface. Use the no form of this command to restore the default configuration. Syntax ip http port port-number no ip http port Parameters port-numberPort number—For use by the HTTP server. (Range: 0–65534) Default Configuration The default port number is 80. Command Mode Global Configuration mode Example The following example configures the http port number as 100. Console(config)# ip http port 100 ip http timeout-policy Use the ip http timeout-policy Global Configuration mode command to set the interval for the system to wait for user input in http sessions before automatic logoff. Use the no form of this command to return to the default value.Web Server Commands 197 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Web_Server.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax ip http timeout-policy idle seconds no ip http timeout-policy Parameters seconds—Specifies the maximum number of seconds that a connection is kept open if no data is received or response data cannot be sent out. (Range: 0–86400) Default 600 seconds Command Mode Global Configuration mode User Guidelines This command also configures the timeout-policy for HTTPS. To specify no timeout, enter the ip http timeout-policy 0 command. Example The following example configures the http port number as 100. Console(config)# ip http timeout-policy 0 ip http secure-server Use the ip http secure-server Global Configuration mode command to enable the device to be configured securely from a browser, and to also enable the device to be monitored or have its configuration modified securely from a browser,. Use the no form of this command to disable this function. Syntax ip http secure-server no ip http secure-server198 Web Server Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Web_Server.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters This command has no arguments or keywords. Default Disabled Command Mode Global Configuration mode User Guidelines Use the crypto certificate generate command to generate an HTTPS certificate. Example console(config)# ip http secure-server ip http secure-port To specify the TCP port to be used by the secure web browser interface, use the ip http secure-port Global Configuration mode command. To use the default port, use the no form of this command. Syntax ip http secure-port port-number no ip http secure-port Parameters port-number—Port number for use by the HTTPS server (Range: 0–65534) Default The default port number is 443. Command Mode Global Configuration modeWeb Server Commands 199 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Web_Server.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example console(config)# ip http secure-port 1234 ip https certificate The ip https certificate Global Configuration mode command configures the active certificate for HTTPS. Use the no form of this command to restore the default configuration. Syntax ip https certificate number no ip https certificate Parameters number—Specifies the certificate number. (Range: 1–2) Default Configuration The default certificate number is 1. Command Mode Global Configuration mode User Guidelines Use the crypto certificate generate command to generate a HTTPS certificate. Example The following example configures the active certificate for HTTPS. Console(config)# ip https certificate 2200 Web Server Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Web_Server.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show ip http The show ip http EXEC mode command displays the HTTP server configuration. Syntax show ip http Command Mode EXEC mode Example The following example displays the HTTP server configuration. Console# show ip http HTTP server enabled Port: 80 Interactive timeout: 10 minutes show ip https The show ip https Privileged EXEC mode command displays the HTTPS server configuration. Syntax show ip https Command Mode Privileged EXEC mode Example The following example displays the HTTPS server configuration. Console# show ip https HTTPS server enabledWeb Server Commands 201 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Web_Server.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Port: 443 Interactive timeout: Follows the HTTP interactive timeout (10 minutes) Certificate 1 is active Issued by: www.verisign.com Valid from: 8/9/2003 to 8/9/2004 Subject: CN= router.gm.com, 0= General Motors, C= US Finger print: DC789788 DC88A988 127897BC BB789788 Certificate 2 is inactive Issued by: self-signed Valid from: 8/9/2003 to 8/9/2004 Subject: CN= router.gm.com, 0= General Motors, C= US Finger print: 1873B936 88DC3411 BC8932EF 782134BA202 Web Server Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Web_Server.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYTelnet, SSH and Slogin Commands 203 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 12 Telnet, SSH and Slogin Commands ip telnet server The ip telnet server Global Configuration mode command enables the device to be configured from a Telnet server. Use the no form of this command to disable the device configuration from a Telnet server. Syntax ip telnet server no ip telnet server Default Configuration Device configuration from a Telnet server is enabled. Command Mode Global Configuration mode User Guidelines To control the device configuration by SSH, use the ip ssh server Global Configuration mode command. Example The following example enables the device to be configured from a Telnet server. Console(config)# ip telnet server204 Telnet, SSH and Slogin Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY ip ssh port The ip ssh port Global Configuration mode command specifies the port used by the SSH server. Use the no form of this command to restore the default configuration. Syntax ip ssh port port-number no ip ssh port Parameters port-number—Specifies the port number to be used by the SSH server. (Range: 1–65535) Default Configuration The default port number is 22. Command Mode Global Configuration mode Example The following example specifies that port number 8080 is used by the SSH server. Console(config)# ip ssh port 8080 ip ssh server The ip ssh server Global Configuration mode command enables the device to be configured from an SSH server. Use the no form of this command to disable the device configuration from a SSH server,. Syntax ip ssh server no ip ssh serverTelnet, SSH and Slogin Commands 205 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration Device configuration from an SSH server is enabled. Command Mode Global Configuration mode User Guidelines If encryption keys are not generated, the SSH server is in standby until the keys are generated. To generate SSH server keys, use the crypto key generate dsa and crypto key generate rsa Global Configuration mode commands. Example The following example enables configuring the device from a SSH server. Console(config)# ip ssh server ip ssh pubkey-auth The ip ssh pubkey-auth Global Configuration mode command enables public key authentication of incoming SSH sessions. Use the no form of this command to disable this function. Syntax ip ssh pubkey-auth no ip ssh pubkey-auth Default Configuration Public Key authentication of incoming SSH sessions is disabled. Command Mode Global Configuration mode User Guidelines AAA authentication is independent.206 Telnet, SSH and Slogin Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables public key authentication for incoming SSH sessions. Console(config)# ip ssh pubkey-auth crypto key pubkey-chain ssh The crypto key pubkey-chain ssh Global Configuration mode command enters the SSH Public Key-chain Configuration mode. This mode is used to manually specify other device public keys such as SSH client public keys. Syntax crypto key pubkey-chain ssh Default Configuration Keys do not exist. Command Mode Global Configuration mode User Guidelines Use this command when you want to manually specify SSH client’s public keys. Example The following example enters the SSH Public Key-chain Configuration mode and manually configures the RSA key pair for SSH public key-chain to ‘bob’. Console(config)# crypto key pubkey-chain ssh Console(config-pubkey-chain)# user-key bob Console(config-pubkey-key)# key-string rsa AAAAB3NzaC1yc2EAAAADAQABAAABAQCvTnRwPWl Al4kpqIw9GBRonZQZxjHKcqKL6rMlQ+ ZNXfZSkvHG+QusIZ/76ILmFT34v7u7ChFAE+ Vu4GRfpSwoQUvV35LqJJk67IOU/zfwOl1gTelnet, SSH and Slogin Commands 207 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY kTwml75QR9gHujS6KwGN2QWXgh3ub8gDjTSq muSn/Wd05iDX2IExQWu08licglk02LYciz +Z4TrEU/9FJxwPiVQOjc+KBXuR0juNg5nFYsY 0ZCk0N/W9a/tnkm1shRE7Di71+w3fNiOA 6w9o44t6+AINEICBCCA4YcF6zMzaT1wefWwX6f+ Rmt5nhhqdAtN/4oJfce166DqVX1gWmN zNR4DYDvSzg0lDnwCAC8Qh Fingerprint: a4:16:46:23:5a:8d:1d:b5:37:59:eb:44:13:b9:33:e9 user-key The user-key SSH Public Key-string Configuration mode command specifies which SSH public key is manually configured. Use the no form of this command to remove an SSH public key. Syntax user-key username {rsa | dsa} no user-key username Parameters • username—Specifies the remote SSH client username. (Length: 1–48 characters) • rsa—Specifies that the RSA key pair is manually configured. • dsa—Specifies that the DSA key pair is manually configured. Default Configuration No SSH public keys exist. Command Mode SSH Public Key-string Configuration mode User Guidelines Follow this command with the key-string SSH Public Key-String Configuration mode command to specify the key.208 Telnet, SSH and Slogin Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Please note that after entering this command, the existing key is deleted even if no new key is defined by the key-string command Exampe The following example enables manually configuring an SSH public key for SSH public key-chain bob. Console(config)# crypto key pubkey-chain ssh Console(config-pubkey-chain)# user-key bob rsa Console(config-pubkey-key)# key-string row AAAAB3NzaC1yc2EAAAADAQABAAABAQCvTnRwPWl key-string The key-string SSH Public Key-string Configuration mode command manually specifies an SSH public key. Syntax key-string [row key-string] Parameters • row—Specifies the SSH public key row by row. • key-string—Specifies the key in UU-encoded DER format. UU-encoded DER format is the same format as in the authorized_keys file used by OpenSSH. (Length:0–160) Default Configuration Keys do not exist. Command Mode SSH Public Key-string Configuration mode User Guidelines Use the key-string SSH Public Key-string Configuration mode command without the row parameter to specify which SSH public key is to be Telnet, SSH and Slogin Commands 209 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY interactively configured next. Enter a row with no characters to complete the command. Use the key-string row SSH Public Key-string Configuration mode command to specify the SSH public key, row by row. Each row must begin with a keystring row command. The UU-encoded DER format is the same format as in the authorized_keys file used by OpenSSH. Example The following example enters public key strings for SSH public key client ‘bob’. Console(config)# crypto key pubkey-chain ssh Console(config-pubkey-chain)# user-key bob rsa Console(config-pubkey-key)# key-string AAAAB3NzaC1yc2EAAAADAQABAAABAQCvTnRwPWl Al4kpqIw9GBRonZQZxjHKcqKL6rMlQ+ ZNXfZSkvHG+QusIZ/76ILmFT34v7u7ChFAE+ Vu4GRfpSwoQUvV35LqJJk67IOU/zfwOl1g kTwml75QR9gHujS6KwGN2QWXgh3ub8gDjTSq muSn/Wd05iDX2IExQWu08licglk02LYciz +Z4TrEU/9FJxwPiVQOjc+KBXuR0juNg5nFYsY 0ZCk0N/W9a/tnkm1shRE7Di71+w3fNiOA 6w9o44t6+AINEICBCCA4YcF6zMzaT1wefWwX6f+ Rmt5nhhqdAtN/4oJfce166DqVX1gWmN zNR4DYDvSzg0lDnwCAC8Qh Fingerprint: a4:16:46:23:5a:8d:1d:b5:37:59:eb:44:13:b9:33:e9 Console(config)# crypto key pubkey-chain ssh Console(config-pubkey-chain)# user-key bob rsa Console(config-pubkey-key)# key-string row AAAAB3Nza Console(config-pubkey-key)# key-string row C1yc2210 Telnet, SSH and Slogin Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show ip ssh The show ip ssh Privileged EXEC mode command displays the SSH server configuration. Syntax show ip ssh Command Mode Privileged EXEC mode Example The following example displays the SSH server configuration. The following table describes the significant fields shown in the display. Console# show ip ssh SSH server enabled. Port: 22 RSA key was generated. DSA (DSS) key was generated. SSH Public Key Authentication is enabled. Active incoming sessions: IP address --------- 172.16.0.1 SSH username ----------- John Brown Version ------- 1.5 Cipher ------ 3DES Auth code ---------- HMAC-SHA1 Field Description IP address The client address SSH username The user name Version The SSH version numberTelnet, SSH and Slogin Commands 211 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show crypto key pubkey-chain ssh The show crypto key pubkey-chain ssh Privileged EXEC mode command displays SSH public keys stored on the device. Syntax show crypto key pubkey-chain ssh [username username] [fingerprint {bubble-babble | hex}] Parameters • username username—Specifies the remote SSH client username. (Length: 1–48 characters) • fingerprint {bubble-babble | hex}—Specifies the fingerprint display format. The possible values are: • bubble-babble—Specifies that the fingerprint is displayed in Bubble Babble format. • hex—Specifies that the fingerprint is displayed in hexadecimal format. Default Configuration The default fingerprint format is hexadecimal. Command Mode Privileged EXEC mode Example The following examples display SSH public keys stored on the device. Console# show crypto key pubkey-chain ssh Username -------- Cipher The encryption type (3DES, Blowfish, RC4) Auth Code The authentication Code (HMAC-MD5, HMAC-SHA1) Field Description212 Telnet, SSH and Slogin Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Telnet_SSH_and_Slogin.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY bob john Fingerprint ----------------------------------------------- 9A:CC:01:C5:78:39:27:86:79:CC:23:C5:98:59:F1:86 98:F7:6E:28:F2:79:87:C8:18:F8:88:CC:F8:89:87:C8 Console# show crypto key pubkey-chain ssh username bob Username: bob Key: 005C300D 06092A86 4886F70D 01010105 00034B00 30480241 00C5E23B 55D6AB22 04AEF1BA A54028A6 9ACC01C5 129D99E4 Fingerprint: 9A:CC:01:C5:78:39:27:86:79:CC:23:C5:98:59:F1:86Line Commands 213 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Line.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 13 Line Commands line The line Global Configuration mode command identifies a specific line for configuration and enters the Line Configuration command mode. Syntax line {console | telnet | ssh} Parameters • console—Enters the console terminal line mode. • telnet—Configures the device as a virtual terminal for remote console access (Telnet). • ssh—Configures the device as a virtual terminal for secured remote console access (SSH). Command Mode Global Configuration mode Example The following example configures the device as a virtual terminal for remote (Telnet) console access. Console(config)# line telnet Console(config-line)#214 Line Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Line.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY speed The speed Line Configuration mode command sets the line baud rate. Use the no form of this command to restore the default configuration. Syntax speed bps no speed Parameters bps—Specifies the baud rate in bits per second (bps). Possible values are 2400, 4800, 9600, 19200, 38400, 57600, and 115200. Default Configuration The default speed is 9600 bps. Command Mode Line Configuration (console) mode User Guidelines The configured speed is applied when Autobaud is disabled. This configuration applies to the current session only. Example The following example configures the line baud rate as 9600 bits per second. Console(config-line)# speed 9600 autobaud The autobaud Line Configuration mode command sets the line for automatic baud rate detection (autobaud). Use the no form of this command to disable automatic baud rate detection. Syntax autobaudLine Commands 215 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Line.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY no autobaud Default Configuration Automatic baud rate detection is disabled. Command Mode Line Configuration mode User Guidelines To start communication using Autobaud, press the Enter key twice. Example The following example enables autobaud. Console(config)# line console Console(config-line)# autobaud exec-timeout The exec-timeout Line Configuration mode command sets the session idle time interval, during which the system waits for user input before automatic logoff. Use the no form of this command to restore the default configuration. Syntax exec-timeout minutes [seconds] no exec-timeout Parameters • minutes—Specifies the number of minutes. (Range: 0-65535) • seconds—Specifies the number of seconds. (Range: 0-59) Default Configuration The default idle time interval is 10 minutes. Command Mode Line Configuration mode216 Line Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Line.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines To specify no timeout, enter the exec-timeout 0 0 command. Example The following example sets the HTTP session idle time interval before automatic logoff to 20 minutes. Console(config)# line console Console(config-line)# exec-timeout 20 show line The show line EXEC mode command displays line parameters. Syntax show line [console | telnet | ssh] Parameters • console—Displays the console configuration. • telnet—Displays the Telnet configuration. • ssh—Displays the SSH configuration. Default Configuration If the line is not specified, all line configuration parameters are displayed. Command Mode EXEC mode Example The following example displays the line configuration. Console> show line Console configuration:Line Commands 217 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Line.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Interactive timeout: Disabled History: 10 Baudrate: 9600 Databits: 8 Parity: none Stopbits: 1 Telnet configuration: Telnet is enabled. Interactive timeout: 10 minutes 10 seconds History: 10 SSH configuration: SSH is enabled. Interactive timeout: 10 minutes 10 seconds History: 10218 Line Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Line.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYAAA Commands 219 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 14 AAA Commands aaa authentication login The aaa authentication login Global Configuration mode command sets an authentication method applied during login. Use the no form of this command to restore the default authentication method. Syntax aaa authentication login {default | list-name} method [method2 ...] no aaa authentication login {default | list-name} Parameters • default—Uses the listed authentication methods that follow this argument as the default method list when a user logs in. • list-name—Specifies a name for a list of authentication methods activated when a user logs in. (Length: 1–12 characters) • method [method2 ...]—Specifies a list of methods that the authentication algorithm tries, in the given sequence. The additional authentication methods are used only if the previous method returns an error, not if it fails. To ensure that the authentication succeeds even if all methods return an error, specify none as the final method in the command line. Select one or more methods from the following list: Keyword Description enable Uses the enable password for authentication. line Uses the line password for authentication. local Uses the local username database for authentication.220 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The local user database is the default authentication method. This is the same as entering the command aaa authentication login local. NOTE: If an authentication method is not defined, console users can log in without any authentication verification. Command Mode Global Configuration mode User Guidelines The default and additional list names created with the aaa authentication login command are used with the login authentication command. Create a list by entering the aaa authentication login list-name method command for a particular protocol, where list-name is any character string used to name ) this list. The method argument identifies the list of methods that the authentication algorithm tries, in the given sequence. The additional methods of authentication are used only if the previous method returns an error, not if it fails. Specify none as the final method in the command line to ensure that the authentication succeeds even if all methods return an error. Example The following example sets the authentication login methods. Console (config)# aaa authentication login default radius local enable none none Uses no authentication. radius Uses the list of all RADIUS servers for authentication. tacacs Uses the list of all TACACS+ servers for authentication.AAA Commands 221 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY aaa authentication enable The aaa authentication enable Global Configuration mode command sets an authentication method for accessing higher privilege levels. To restore the default authentication method, use the no form of this command. Syntax aaa authentication enable {default | list-name} method [method2 ...] no aaa authentication enable {default | list-name} Parameters • default—Uses the listed authentication methods that follow this argument as the default method list, when accessing higher privilege levels. • list-name —Specifies a name for the list of authentication methods activated when a user accesses higher privilege levels. (Length: 1–12 characters) • method [method2 ...]—Specifies a list of methods that the authentication algorithm tries, in the given sequence. The additional authentication methods are used only if the previous method returns an error, not if it fails. Specify none as the final method in the command line to ensure that the authentication succeeds, even if all methods return an error. Select one or more methods from the following list: Keyword Description enable Uses the enable password for authentication. line Uses the line password for authentication. none Uses no authentication. radius Uses the list of all RADIUS servers for authentication. Uses username "$enabx$." where x is the privilege level. tacacs Uses the list of all TACACS servers for authentication. Uses username "$enabx$." where x is the privilege level.222 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The enable password command is the default authentication login method. This is the same as entering the command aaa authentication enable default enable. On a console, the enable password is used if a password exists. If no password is set, authentication still succeeds. This is the same as entering the command aaa authentication enable default enable none. Command Mode Global Configuration mode User Guidelines The default and additional list names created with the aaa authentication enable command are used with the enable authentication command. All aaa authentication enable default requests sent by the device to a RADIUS or TACACS+ server include the username $enabx$., where x is the requested privilege level. Create a list by entering the aaa authentication enable list-name method command where list-name is any character string used to name this list. The method argument identifies the list of methods that the authentication algorithm tries, in the given sequence. The additional methods of authentication are used only if the previous method returns an error, not if it fails. Specify none as the final method in the command line to ensure that the authentication succeeds even if all methods return an error. Example The following example sets the enable password for authentication for accessing higher privilege levels. Console(config)# aaa authentication enable default enableAAA Commands 223 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY login authentication The login authentication Line Configuration mode command specifies the login authentication method list for a remote Telnet or console session. Use the no form of this command to restore the default authentication method. Syntax login authentication {default | list-name} no login authentication Parameters • default—Uses the default list created with the aaa authentication login command. • list-name—Uses the specified list created with the aaa authentication login command. (Length: 1–12 characters). Default Configuration The default is the aaa authentication login command default. Command Mode Line Configuration mode Example The following example specifies the login authentication method for a console session. Console(config)# line console Console(config-line)# login authentication default enable authentication The enable authentication Line Configuration mode command specifies the authentication method for accessing a higher privilege level from a remote Telnet or console. Use the no form of this command to restore the default authentication method.224 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax enable authentication {default | list-name} no enable authentication Parameters • default—Uses the default list created with the aaa authentication enable command. • list-name—Uses the specified list created with the aaa authentication enable command. (Length: 1–12 characters). Default Configuration The default is the aaa authentication enable command default. Command Mode Line Configuration mode Example The following example specifies the authentication method when accessing a higher privilege level from a console. Console(config)# line console Console(config-line)# enable authentication default ip http authentication The ip http authentication Global Configuration mode command specifies authentication methods for HTTP server access. Use the no form of this command to restore the default authentication method. Syntax ip http authentication aaa login-authentication method1 [method2...] no ip http authentication aaa login-authentication Parameters method [method2 ...]—Specifies a list of methods that the authentication algorithm tries, in the given sequence. The additional authentication AAA Commands 225 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY methods are used only if the previous method returns an error, not if it fails. Specify none as the final method in the command line to ensure that the authentication succeeds, even if all methods return an error. Select one or more methods from the following list: Default Configuration The local user database is the default authentication login method. This is the same as entering the ip http authentication local command. Command Mode Global Configuration mode User Guidelines The command is relevant for HTTP and HTTPS server users. The additional methods of authentication are used only if the previous method returns an error, not if it fails. Specify none as the final method in the command line to ensure that the authentication succeeds, even if all methods return an error. Example The following example specifies the HTTP access authentication methods. Console(config)# ip http authentication aaa login-authentication radius local show authentication methods The show authentication methods Privileged EXEC mode command displays information about the authentication methods. Keyword Description local Uses the local username database for authentication. none Uses no authentication. radius Uses the list of all RADIUS servers for authentication. tacacs Uses the list of all TACACS+ servers for authentication.226 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show authentication methods Command Mode Privileged EXEC mode Example The following example displays the authentication configuration. password The password Line Configuration mode command specifies a password on a line, also known as access method, such as a console or Telnet. Use the no form of this command to return to the default password. Console# show authentication methods Login Authentication Method Lists --------------------------------- Default: Radius, Local, Line Console_Login: Line, None Enable Authentication Method Lists ---------------------------------- Default: Radius, Enable Console_Enable: Enable, None Line -------------- Console Telnet SSH Login Method List ----------------- Console_Login Default Default Enable Method List ------------------ Console_Enable Default Default HTTP: Radius, local HTTPS: Radius, local Dot1x: RadiusAAA Commands 227 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax password password [encrypted] no password Parameters • password—Specifies the password for this line. (Length: 0–159 characters) • encrypted—Specifies that the password is encrypted and copied from another device configuration. Default Configuration No password is defined. Command Mode Line Configuration mode Example The following example specifies the password ‘secret’ on a console. Console(config)# line console Console(config-line)# password secret service password-recovery Use the service password-recovery global configuration mode command to enable full functionality of the password-recovery mechanism. Use the no service password-recovery command to allow password-recovery mechanism without keeping the configuration and user files. Syntax service password-recovery no service password-recovery Parameters N/A228 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The full service password recovery is enabled by default. Command Mode Gobal Configuration mode User Guidelines This mechanism allows an end user, with physical access to the console port of the device, to enter the boot menu and trigger the password recovery process. The following functionality occurs: • If password recovery is enabled, the user can access the boot menu and trigger the password recovery in the boot menu. All configuration files and user files are kept. • If password recovery is disabled, the user still can access the boot menu and trigger the password recovery in the boot menu. However, the configuration files and user files are removed, and the following log message is generated to the terminal: “All the configuration and user files were removed” Example The following command disables password recovery: console# no service password recovery Note that choosing to use Password recovery option in the Boot Menu during the boot process will remove the configuration files and the user files. Would you like to continue ? Y/N. enable password Use the enable password Global Configuration mode command to set a local password to control access to normal and privilege levels. Use the no form of this command to return to the default password.AAA Commands 229 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax enable password [ level privilege-level ] { password | encrypted encryptedpassword } no enable password [ level level ] Parameters • level privilege-level—Level for which the password applies. If not specified the level is 15. (Range: 1–15) • password—Password for this level. (Range: 0–159 chars) • encrypted-password—Encrypted password you enter, copied from another device configuration. Default Default for level is 15. Command Mode Global Configuration mode Example console(config)# enable password level 15 let-me-in username Use the username Global Configuration mode command to establish a username-based authentication system. Use the no form to remove a user name. Syntax username name { nopassword | password password | privilege privilege-level | password encrypted encrypted-password } username name no username name230 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • name—The name of the user. (Range: 1–20 characters) • nopassword—No password is required for this user to log in. • password—The authentication password for the user. (Range: 1–159) • password-encrypted—Encrypted password you enter, copied from another device configuration. • privilege privilege-level —Privilege level for which the password applies. If not specified the level is 15. (Range: 1–15) Default No user is defined. Command Mode Global Configuration mode Example console(config)# username tom privilege 15 password 1234 show user accounts The show user accounts Privileged EXEC mode command displays information about the users local database. Syntax show user accounts Command Mode Privileged EXEC modeAAA Commands 231 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays information about the users local database. The following table describes the significant fields shown in the display: aaa accounting login Use the aaa accounting login command in Global Configuration mode to enable accounting of device management sessions. Use the no form of this command to disable accounting. Syntax aaa accounting login start-stop group radius no aaa accounting login start-stop group radius Parameters This command has no arguments or keywords. Default Disabled Command Mode Global Configuration mode Console# show user accounts Username -------- Bob Robert Smith Privilege --------- 15 15 15 Field Description Username The user name. Privilege The user’s privilege level.232 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines This command enables the recording of device management sessions (Telnet, serial and WEB but not SNMP). It records only users that were identified with a username (e.g. a user that was logged in with a line password is not recorded). If accounting is activated, the device sends a “start”/“stop” messages to a Radius server when a user logs in / logs out respectively. The device uses the configured priorities of the available Radius servers in order to select the Radius server. The following table describes the supported Radius accounting Attributes Values, and when they are sent by the switch. Example console(config)# aaa accounting login start-stop group radius Name Start Stop Description User-Name (1) Yes Yes User’s identity. NAS-IP-Address (4) Yes Yes The switch IP address that is used for the session with the Radius server. Class (25) Yes Yes Arbitrary value is included in all accounting packets for a specific session. Called-Station-ID (30) Yes Yes The switch IP address that is used for the management session. Calling-Station-ID (31) Yes Yes The user IP address. Acct-Session-ID (44) Yes Yes A unique accounting identifier. Acct-Authentic (45) Yes Yes Indicates how the supplicant was authenticated. Acct-Session-Time (46) No Yes Indicates how long the user was logged in. Acct-Terminate-Cause (49) No Yes Reports why the session was terminated.AAA Commands 233 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY aaa accounting dot1x To enable accounting of 802.1x sessions, use the aaa accounting dot1x Global Configuration mode command. Use the no form of this command to disable accounting. Syntax aaa accounting dot1x start-stop group radius no aaa accounting dot1x start-stop group radius Parameters This command has no arguments or keywords. Default Disabled Command Mode Global Configuration mode User Guidelines This command enables the recording of 802.1x sessions. If accounting is activated, the device sends a “start”/“stop” messages to a Radius server when a user logs in / logs out to the network, respectively. The device uses the configured priorities of the available Radius servers in order to select the Radius server. If a new replaces an old supplicant (even if the port state remains authorized), the software sends a “stop” message for the old supplicant and a “start” message for the new supplicant. In multiple sessions mode (dot1x multiple-hosts authentication), the software sends “start”/“stop” messages for each authenticated supplicant. In multiple hosts mode (dot1x multiple-hosts), the software sends “start”/“stop” messages only for the supplicant that has been authenticated.234 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY The software does not send “start”/“stop” messages if the port is forceauthorized. The software does not send “start”/“stop” messages for hosts that are sending traffic on the guest VLAN or on the unauthenticated VLANs. The following table describes the supported Radius accounting Attributes Values and when they are sent by the switch. Example console(config)# aaa accounting dot1x start-stop group radius Name Start Stop Description User-Name (1) Yes Yes Supplicant’s identity. NAS-IP-Address (4) Yes Yes The switch IP address that is used for the session with the Radius server. NAS-Port (5) Yes Yes The switch port from where the supplicant has logged in. Class (25) Yes Yes Arbitrary value is included in all accounting packets for a specific session. Called-Station-ID (30) Yes Yes The switch MAC address. Calling-Station-ID (31) Yes Yes The supplicant MAC address. Acct-Session-ID (44) Yes Yes A unique accounting identifier. Acct-Authentic (45) Yes Yes Indicates how the supplicant was authenticated. Acct-Session-Time (46) No Yes Indicated how long the supplicant was logged in. Acct-Terminate-Cause (49) No Yes Reports why the session was terminated. Nas-Port-Type (61) Yes Yes Indicates the supplicant physical port type.AAA Commands 235 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show accounting The show accounting EXEC mode command displays information about the accounting status. Syntax show accounting Command Mode EXEC mode Example The following example displays information about the accounting status. Console# show accounting Login: Radius 802.1x: Disabled passwords min-length The passwords min-length Global Configuration mode command configures the minimal password length in the local database. Use the no form of this command to remove the restriction. Syntax passwords min-length length no passwords min-length Parameters length—Specifies the minimal length required for passwords. (Range: 8-64) Default Configuration There is no minimal length requirement until this command is executed.236 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode User Guidelines The setting is relevant to local user passwords, line passwords, and enable passwords. The software checks the minimum length requirement when defining a password in an unencrypted format, or when a user tries to log in. Note that if a password is inserted in encrypted format, the minimum length requirement is checked during user login only. Passwords that were defined before defining the minimum length requirement are only checked during user login. Example The following example configures the minimal required password length to 8 characters. Console (config)# passwords min-length 8 passwords strength-check enable Use the passwords strength-check enable Global Configuration mode command to enforce minimum password strength. The no form of this command disables enforcing password strength. Syntax passwords strength-check enable no passwords strength-check enable Parameters This command has no arguments or keywords Default DisabledAAA Commands 237 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode User Guidelines If password strength is enabled, the user is forced to enter passwords that: • Contain characters from user-defined several character classes (uppercase letters, lowercase letters, numbers, and special characters available on a standard keyboard). • Contain no character that is repeated more than user-defined times consecutively. The user can control the above attributes of password strength with specific commands. Example The following example enables password strength and configures the character classes to 3. Console (config)# passwords strength-check enable Console (config)# passwords strength minimum character-classes 3 passwords strength minimum character-classes Use the passwords strength minimum character-classes Global Configuration mode command to configure the minimal classes required for passwords in the local database. Use the no form to remove the requirement. Syntax passwords strength minimum character-classes number no passwords strength minimum character-classes Parameters number—The minimal length required for passwords.(Range: 0–4) Default 0238 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode User Guidelines The setting is relevant to local users’ passwords, line passwords and enable passwords. The software checks the minimum length requirement when you define a password in an unencrypted format. The classes are: upper case letters, lower case letters, numbers and special characters. passwords strength max-limit repeatedcharacters Use the passwords strength max-limit repeated-characters Global Configuration mode command to configure the maximum number of characters in the new password that can be repeated consecutively. Use the no form to remove the requirement. Syntax passwords strength max-limit repeated-characters number no passwords strength max-limit repeated-characters Parameters number—The maximum number of characters in the new password that can be repeated consecutively. (Range: 1–16) Default 1 Command Mode Global Configuration modeAAA Commands 239 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines The setting is relevant to local users’ passwords, line passwords and enable passwords. The software checks the maximum number of characters in the new password that can be repeated consecutively. passwords aging Use the passwords aging Global Configuration mode command to enforce password aging. Use the no form of this command to return to default. Syntax passwords aging days no passwords aging Parameters days—Specifies the number of days before a password change is forced. You can use 0 to disable aging. (Range: 0–365) Default Disabled Command Mode Global Configuration mode User Guidelines Aging is relevant only to users of the local database with privilege level 15 and to “enable” a password of privilege level 15. Example The following example configures the aging time to be 24. Console (config)# passwords aging 24240 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY passwords history The passwords history Global Configuration mode command configures the number of password changes required before a password can be reused. Use the no form of this command to remove the requirement. Syntax passwords history number no passwords history Parameters number—Specifies the number of password changes required before a password can be reused. (Range: 1–8) Default Configuration Password history is disabled. Command Mode Global Configuration mode User Guidelines The setting is relevant to local users’ passwords, line passwords and enable passwords. Password history is not checked during a configuration download. The password history is kept even if the password history check is disabled. The password history for a user is kept as long as the user is defined. Example The following example sets the number of password changes required before a password can be reused to 10. Console(config)# passwords history 10AAA Commands 241 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY passwords history hold-time The passwords history hold-time Global Configuration mode command configures the duration that a password is relevant for tracking passwords history. Use the no form of this command to return to the default configuration. Syntax passwords history hold-time days no passwords history hold-time Parameters days—Specifies the number of days a password is relevant for tracking passwords history. (Range: 1–365) Default Configuration Command Mode Global Configuration mode User Guidelines The setting is relevant to local users’ passwords, line passwords and enable passwords. The passwords are not deleted from the history database when they are not relevant for the password history tracking. Increasing the hold time might "return back" passwords. Example The following example configures the duration that a password is relevant for tracking passwords history. Console(config)# passwords history hold-time 10242 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY passwords lockout The passwords lockout Global Configuration mode command enables user account lockout after a series of authentication failures. Use the no form of this command to disable the lockout feature. Syntax passwords lockout number no passwords lockout Parameters number—Specifies the number of authentication failures before the user account is locked-out. (Range: 1–5) Default Configuration Lockout is disabled. Command Mode Global Configuration mode User Guidelines The setting is relevant to local users’ passwords, line passwords and enable passwords. The account is not locked out for access from the local console. A user with privilege level 15 can release accounts that are locked out by using the set username active, set enable-password active and set line active Privileged EXEC mode commands. Disabling lockout unlocks all users. Re-enabling lockout resets the authentication failures counters. Changing the authentication failures threshold does not reset the counters.AAA Commands 243 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables user account lockout after 3 successive authentication failures. Console(config)# passwords lockout 3 aaa login-history file The aaa login-history file Global Configuration mode command enables writing to the login history file. Use the no form of this command to disable writing to the login history file. Syntax aaa login-history file no aaa login-history file Default Configuration Writing to the login history file is enabled. Command Mode Global Configuration mode User Guidelines The login history is stored in the device internal buffer. Example The following example enables writing to the login history file. Console(config)# aaa login-history file set username active The set username active Privileged EXEC mode command reactivates a locked out user account.244 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax set username name active Parameters name—Specifies the user name: (Length: 1–20 characters) Default Configuration There is no default configuration for this command. Command Mode Privileged EXEC mode Example The following example reactivates user ‘Bob’. Console(config)# set username Bob active set line active The set line active Privileged EXEC mode command reactivates a locked out line. Syntax set line {console | telnet | ssh} active Parameters • console—Reactivates the console terminal line. • telnet—Reactivates the virtual terminal for remote (Telnet) console access. • ssh—Reactivates the virtual terminal for secured remote (SSH) console access. Default Configuration There is no default configuration for this command.AAA Commands 245 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Privileged EXEC mode Example The following example reactivates the virtual terminal for remote (Telnet) console access. Console(config)# set line telnet active set enable-password active The set enable-password active Privileged EXEC mode command reactivates a locked out local password. Syntax set enable-password level active Parameters level—Specifies the privilege level to which the password applies. (Range 1–15) Default Configuration There is no default configuration for this command. Command Mode Privileged EXEC mode Example The following example reactivates a local password that applies to privilege level 1. Console(config)# set enable-password 1 active246 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show passwords configuration The show passwords configuration Privileged EXEC mode command displays information about the password management configuration. Syntax show passwords configuration Parameters Command Mode Privileged EXEC mode Example Console# show passwords configuration Passwords aging is enabled with aging time 180 days. Minimal length: 8 Minimum character classes: 4 Maximal number of repeated characters: 2 History: 10 History hold time: 365 days Lockout control: Disabled Enable Passwords Level Lockout ----- --------- 1 1 15 0 Line Passwords Line Lockout ----- ------------ ConsoleTelnet LOCKOUT SSH 0AAA Commands 247 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes the significant fields shown in the display: show users login-history The show users login-history Privileged EXEC mode command displays information about the user’s login history. Syntax show users login-history [username name] Parameters name—Name of the user. (Range: 1–20 characters) Field Description Minimal length The minimal length required for passwords in the local database. Minimal character classes The minimal number of different types of characters (special characters, integers and so on) required to be part of the password. Maximum number of repeated characters The maximum number of times a singe character can be repeated in the password. History The number of password changes required before a password in the local database can be reused. History hold time The duration that a password is relevant for tracking password history. Lockout control The user account lockout control status after a series of authentication failures. Level The applied password privilege level. Aging The password aging time in days. Expiry date The password expiration date. Lockout If lockout control is enabled, the specific number of times a user failed to enter the correct password since the last successful login is displayed. If the user is locked out, "LOCKOUT" is displayed. Line The applied password line type.248 AAA Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\AAA.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Privileged EXEC mode Example The following example displays information about the users’ login history. Console# show users login-history File save: Enabled. Login Time -------------------- Jan 18 2004 23:58:17 Jan 19 2004 07:59:23 Jan 19 2004 08:23:48 Jan 19 2004 08:29:29 Jan 19 2004 08:42:31 Jan 19 2004 08:49:52 Username ---------- Robert Robert Bob Robert John Betty Protocol ---------- HTTP HTTP Serial HTTP SSH Telnet Location ------------ 172.16.1.8 172.16.0.8 172.16.0.8 172.16.0.1 172.16.1.7RADIUS Commands 249 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 15 RADIUS Commands radius-server host Use the radius-server host Global Configuration mode command to specify a RADIUS server host. Use the no form of the command to delete the specified RADIUS server host. Syntax radius-server host {ipv4-address | ipv6-address | ipv6z-address | hostname} [auth-port auth-port-number] [timeout timeout] [retransmit retries] [deadtime deadtime] [key key-string] [source {ipv4-address | ipv6-address}] [priority priority] [usage {login | 802.1x | all}] no radius-server host {ipv4-address | ipv6-address | hostname} Parameters • ipv4-address—Specifies the RADIUS server host IPv4 address. • ipv6-address—Specifies the RADIUS server host IPv6 address. • ipv6z-address—Specifies the RADIUS server host IPv6Z address. The IPv6Z address format is: {ipv6-link-local-address}%{interface-name}. The subparameters are: • ipv6-link-local-address—Specifies the IPv6 Link Local address. • interface-name—Specifies the outgoing interface name. The interface name has the format: vlan{integer} | ch{integer} | isatap{integer} | {physical-portname}. • The subparameter integer has the format: {decimal-digit} | {integer}{decimal-digit}. decimal-digit has the range 0–9.250 RADIUS Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • hostname—Specifies the RADIUS server host name. Translation to IPv4 addresses only is supported. (Length: 1–158 characters. Maximum label length: 63 characters) • auth-port auth-port-number—Specifies the port number for authentication requests. If the port number is set to 0, the host is not used for authentication. (Range: 0–65535) • timeout timeout—Specifies the timeout value in seconds. (Range: 1–30) • retransmit retries—Specifies the retransmit value. (Range: 1–10) • deadtime deadtime—Specifies the length of time in minutes during which a RADIUS server is skipped over by transaction requests. (Range: 0–2000) • key key-string—Specifies the authentication and encryption key for all RADIUS communications between the device and the RADIUS server. This key must match the encryption used on the RADIUS daemon. To specify an empty string, enter "". (Length: 0–128 characters) • source {ipv4-address | ipv6-address}—Specifies the source IPv4 or IPv6 address to use for communication. 0.0.0.0 is interpreted as a request to use the IP address of the outgoing IP interface. • priority priority—Specifies the order in which servers are used, where 0 has the highest priority. (Range: 0–65535) • usage {login | 802.1x | all}—Specifies the RADIUS server usage type. The possible values are: • login—Specifies that the RADIUS server is used for user login parameters authentication. • 802.1x—Specifies that the RADIUS server is used for 802.1x port authentication. • all—Specifies that the RADIUS server is used for user login parameters authentication and 802.1x port authentication. Default Configuration No RADIUS host is specified; the global radius-server command values are the default values. The default authentication port number is 1812. If timeout is not specified, the global value is used.RADIUS Commands 251 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY If retransmit is not specified, the global value is used. If key-string is not specified, the global value is used. If the source value is not specified, the global value is used. The default usage type is all. Command Mode Global Configuration mode User Guidelines To specify multiple hosts, multiple radius-server host commands can be used. If no host-specific timeout, retries, deadtime or key-string values are specified, the global values apply to each RADIUS server host. The source parameter address type must be the same as that of the host parameter. Example The following example specifies a RADIUS server host with IP address 192.168.10.1, authentication request port number 20, and a 20-second timeout period. Console(config)# radius-server host 192.168.10.1 auth-port 20 timeout 20 radius-server key Use the radius-server key Global Configuration mode command to set the authentication and encryption key for all RADIUS communications between the device and the RADIUS daemon. Use the no form of this command to restore the default configuration. Syntax radius-server key [key-string] no radius-server key252 RADIUS Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters key-string—Specifies the authentication and encryption key for all RADIUS communications between the device and the RADIUS server. This key must match the encryption used on the RADIUS daemon. (Range: 0–128 characters) Default Configuration The key-string is an empty string. Command Mode Global Configuration mode Example The following example defines the authentication and encryption key for all RADIUS communications between the device and the RADIUS daemon. Console(config)# radius-server key enterprise-server radius-server retransmit Use the radius-server retransmit Global Configuration mode command to specify the number of times the software searches the list of RADIUS server hosts. Use the no form of this command to restore the default configuration. Syntax radius-server retransmit retries no radius-server retransmit Parameters retries—Specifies the retransmit value. (Range: 1–10) Default Configuration The software searches the list of RADIUS server hosts 3 times. Command Mode Global Configuration modeRADIUS Commands 253 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example configures the number of times the software searches all RADIUS server hosts as 5. console(config)# radius-server retransmit 5 radius-server source-ip Use the radius-server source-ip Global Configuration mode command to specify the source IP address used for communication with RADIUS servers. Use the no form of this command to restore the default configuration. Syntax radius-server source-ip {source} no radius-server source-ip {source} Parameters source—Specifies the source IP address. Default Configuration The source IP address is the IP address of the outgoing IP interface. Command Mode Global Configuration mode User Guidelines If there is no available IP interface of the configured IP source address, an error message is issued when attempting to communicate with the IP address. Example The following example configures the source IP address used for communication with all RADIUS servers to 10.1.1.1. console(config)# radius-server source-ip 10.1.1.1254 RADIUS Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY radius-server source-ipv6 Use the radius-server source-ipv6 Global Configuration mode command to specify the source IPv6 address used for communication with RADIUS servers. Use the no form of this command to restore the default configuration. Syntax radius-server source-ipv6 {source} no radius-server source-ipv6 {source} Parameters source—Specifies the source IPv6 address. Default Configuration The source IP address is the IP address of the outgoing IP interface. Command Mode Global Configuration mode User Guidelines If there is no available IP interface of the configured IP source address, an error message is issued when attempting to communicate with the IP address. Example The following example configures the source IP address used for communication with all RADIUS servers to 3ffe:1900:4545:3:200:f8ff:fe21:67cf. console(config)# radius-server source-ipv6 3ffe:1900:4545:3:200:f8ff:fe21:67cfRADIUS Commands 255 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY radius-server timeout Use the radius-server timeout Global Configuration mode command to set the time interval during which the device waits for a server host to reply. Use the no form of this command to restore the default configuration. Syntax radius-server timeout timeout no radius-server timeout Parameters timeout—Specifies the timeout value in seconds. (Range: 1–30) Default Configuration The default timeout value is 3 seconds. Command Mode Global Configuration mode Example The following example sets the timeout interval on all RADIUS servers to 5 seconds. Console(config)# radius-server timeout 5 radius-server deadtime Use the radius-server deadtime Global Configuration mode command to configure the time interval during which unavailable RADIUS servers are skipped over by transaction requests. This improves RADIUS response time when servers are unavailable. Use the no form of this command to restore the default configuration. Syntax radius-server deadtime deadtime no radius-server deadtime256 RADIUS Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters deadtime—Specifies the time interval in minutes during which a RADIUS server is skipped over by transaction requests. (Range: 0–2000) Default Configuration The default deadtime interval is 0. Command Mode Global Configuration mode Example The following example sets all RADIUS server deadtimes to 10 minutes. Console(config)# radius-server deadtime 10 show radius-servers Use the show radius-servers Privileged EXEC mode command to display the RADIUS server settings. Syntax show radius-servers Command Mode Privileged EXEC modeRADIUS Commands 257 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays RADIUS server settings. Console# show radius-servers IP address ---------- 172.16.1.1 172.16.1.2 Port Auth ---- 1812 1812 Port Acct ---- 1813 1813 Time Out ----- Global 11 Retrans mit ------- Global 8 Dead time ------ Global Global Source IP ------ Global Global Priority -------- 1 2 Usage ----- All All Global values -------------- TimeOut: 3 Retransmit: 3 Deadtime: 0 Source IP: 172.16.8.1258 RADIUS Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Radius.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYTACACS+ Commands 259 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\TACACS.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 16 TACACS+ Commands tacacs-server host Use the tacacs-server host Global Configuration mode command to specify a TACACS+ host. Use the no form of this command to delete the specified TACACS+ host. Syntax tacacs-server host {ip-address | hostname} [single-connection] [port portnumber] [timeout timeout] [key key-string] [source {source}] [priority priority] no tacacs-server host {ip-address | hostname} Parameters • ip-address—Specifies the TACACS+ server host IP address. • hostname—Specifies the TACACS+ server host name. (Length: 1-158 characters. Maximum label length: 63 characters) • single-connection—Specifies that a single open connection is maintained between the device and the daemon, instead of the device opening and closing a TCP connection to the daemon each time it communicates. • port port-number—Specifies the server port number. If the port number is 0, the host is not used for authentication. (Range: 0–65535) • timeout timeout—Specifies the timeout value in seconds. (Range: 1–30) • key key-string—Specifies the authentication and encryption key for all TACACS+ communications between the device and the TACACS+ server. This key must match the encryption used on the TACACS+ daemon. To specify an empty string, enter "". (Length: 0-128 characters)260 TACACS+ Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\TACACS.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • source {source}—Specifies the source IP to use for the communication. 0.0.0.0 indicates a request to use the outgoing IP interface IP address. • priority priority—Specifies the order in which the TACACS+ servers are used, where 0 is the highest priority. (Range: 0–65535) Default Configuration No TACACS+ host is specified. The default port-number is 49. If timeout is not specified, the global value is used. If key-string is not specified, the global value is used. If source is not specified, the global value is used. Command Mode Global Configuration mode User Guidelines Multiple tacacs-server host commands can be used to specify multiple hosts. If no host-specific timeout, key, or source values are specified, the global values apply to each host. Example The following example specifies a TACACS+ host. Console(config)# tacacs-server host 172.16.1.1 tacacs-server key Use the tacacs-server key Global Configuration mode command to ses the authentication encryption key used for all TACACS+ communications between the device and the TACACS+ daemon. Use the no form of this command to disable the key. Syntax tacacs-server key key-string no tacacs-server keyTACACS+ Commands 261 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\TACACS.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters key-string—Specifies the authentication and encryption key for all TACACS+ communications between the device and the TACACS+ server. This key must match the encryption used on the TACACS+ daemon. (Length: 0–128 characters) Default Configuration The default key is an empty string. Command Mode Global Configuration mode Example The following example sets Enterprise as the authentication encryption key for all TACACS+ servers. Console(config)# tacacs-server key enterprise tacacs-server timeout Use the tacacs-server timeout Global Configuration mode command to set the interval during which the device waits for a TACACS+ server to reply. Use the no form of this command to restore the default configuration. Syntax tacacs-server timeout timeout no tacacs-server timeout Parameters timeout—Specifies the timeout value in seconds. (Range: 1–30) Default Configuration The default timeout value is 5 seconds. Command Mode Global Configuration mode262 TACACS+ Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\TACACS.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example sets the timeout value to 30 for all TACACS+ servers. Console(config)# tacacs-server timeout 30 tacacs-server source-ip Use the tacacs-server source-ip Global Configuration mode command to configure the source IP address to be used for communication with TACACS+ servers. Use the no form of this command to restore the default configuration. Syntax tacacs-server source-ip {source} no tacacs-server source-ip {source} Parameters source—Specifies the source IP address. (Range: Valid IP address) Default Configuration The default source IP address is the outgoing IP interface address. Command Mode Global Configuration mode User Guidelines If the configured IP source address has no available IP interface, an error message is issued when attempting to communicate with the IP address. Example The following example specifies the source IP address for all TACACS+ servers. Console(config)# tacacs-server source-ip 172.16.8.1TACACS+ Commands 263 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\TACACS.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show tacacs Use the show tacacs Privileged EXEC mode command to display configuration and statistical information for a TACACS+ server. Syntax show tacacs [ip-address] Parameters ip-address—Specifies the TACACS+ server name or IP address. Default Configuration If ip-address is not specified, information for all TACACS+ servers is displayed. Command Mode Privileged EXEC mode Example The following example displays configuration and statistical information for all TACACS+ servers. Console# show tacacs IP address -------- 172.16.1.1 Status -------- Connected Port --- 49 Single Connection --------- No Time Out ----- Global Source IP ----- Global Priority ------ 1 Global values ------------- TimeOut: 3 Source IP: 172.16.8.1264 TACACS+ Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\TACACS.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYSyslog Commands 265 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 17 Syslog Commands logging on Use the logging on Global Configuration mode command to control error message logging. This command sends debug or error messages to a logging process, which logs messages asynchronously to designated locations for the process that generated the messages. Use the no form of this command to disable the logging process. Syntax logging on no logging on Default Configuration Message logging is enabled. Command Mode Global Configuration mode User Guidelines The logging process controls the logging messages distribution at various destinations, such as the logging buffer, logging file or syslog server. Logging on and off at these destinations can be individually configured using the logging buffered, logging file, and logging Global Configuration mode commands. However, if the logging on command is disabled, no messages are sent to these destinations. Only the console receives messages.266 Syslog Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables logging error messages. Console(config)# logging on Logging host Use the logging host global configuration command to log messages to a syslog server. Use the no form of this command to delete the syslog server with the specified address from the list of syslogs. Syntax logging host {ipv4-address | ipv6-address | hostname} [port port] [severity level] [facility facility] [description text] no logging host {ipv4-address | ipv6-address | hostname} Parameters • ipv4-address—IPv4 address of the host to be used as a syslog server. • ipv6-address—Pv6 address of the host to be used as a syslog server. When the IPv6 address is a Link Local address (IPv6Z address), the outgoing interface name must be specified. Refer to the User Guidelines for the interface name syntax. • hostname—Hostname of the host to be used as a syslog server. Only translation to IPv4 addresses is supported. (Range: 1–158 characters. Maximum label size: 63) • port—Port number for syslog messages. If unspecified, the port number defaults to 514. (Range: 1–65535) • level—Limits the logging of messages to the syslog servers to a specified level: emergencies, alerts, critical, errors, warnings, notifications, informational, debugging. • facility—The facility that is indicated in the message. It can be one of the following values: local0, local1 , local2 , local3 , local4 , local5 , local 6, local7. If unspecified, the port number defaults to local7. • text—Description of the syslog server. (Range: Up to 64 characters)Syslog Commands 267 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default No messages are logged to a syslog server host. Command Mode Global Configuration mode User Guidelines You can use multiple syslog servers. The format of an IPv6Z address is: % interface-name = vlan | ch | isatap | | 0 integer = | decimal-number = 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 physical-port-name = Designated port number, for example 1/0/16. If the egress interface is not specified, the default interface is selected. Specifying interface zone=0 is equal to not defining an egress interface. Examples console(config)# logging host 1.1.1.121 console(config)# logging host 3000::100 logging console Use the logging console Global Configuration mode command to limit messages logged to the console to messages with a specific severity level. Use the no form of this command to disable logging limiting to the console. Syntax logging console level no logging console268 Syslog Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters level—Specifies the severity level of logged messages displayed on the console. The possible values are: emergencies, alerts, critical, errors, warnings, notifications, informational and debugging. Default Configuration The default severity level is informational. Command Mode Global Configuration mode Example The following example limits logging messages displayed on the console to messages with severity level errors. Console(config)# logging console errors logging buffered Use the logging buffered Global Configuration mode command to limit the syslog message display from an internal buffer to messages with a specific severity leve, and to define the buffer sizel. Use the no form of this command to cancel using the buffer and returning the buffer size to defult Syntax logging buffered [buffer-size] [severity-level] no logging buffered Parameters buffer-size—Specifies the maximum number of messages stored in the history table. (Range: 20–400) severity-level—Specifies the severity level of messages logged in the buffer. The possible values are: emergencies, alerts, critical, errors, warnings, notifications, informational and debugging.Syslog Commands 269 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The default severity level is informational. Command Mode Global Configuration mode User Guidelines All the syslog messages are logged to the internal buffer. This command limits the messages displayed to the user. Example The following example limits the syslog message display from an internal buffer to messages with severity level debugging. Console(config)# logging buffered debugging clear logging Use the clear logging Privileged EXEC mode command to clear messages from the internal logging buffer. Syntax clear logging Command Mode Privileged EXEC mode Example The following example clears messages from the internal logging buffer. Console# clear logging Clear logging buffer [confirm]270 Syslog Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY logging file Use the logging file Global Configuration mode command to limit syslog messages sent to the logging file to messages with a specific severity level. Use the no form of this command to cancel using the buffer. Syntax logging file level no logging file Parameters level—Specifies the severity level of syslog messages sent to the logging file. The possible values are: emergencies, alerts, critical, errors, warnings, notifications, informational and debugging. Default Configuration The default severity level is errors. Command Mode Global Configuration mode Example The following example limits syslog messages sent to the logging file to messages with severity level alerts. Console(config)# logging file alerts clear logging file Use the clear logging file Privileged EXEC mode command to clear messages from the logging file. Syntax clear logging fileSyslog Commands 271 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Privileged EXEC mode Example The following example clears messages from the logging file. Console# clear logging file Clear Logging File [y/n] aaa logging Use the aaa logging Global Configuration mode command to enable logging AAA login events. Use the no form of this command to disable logging AAA login events. Syntax aaa logging {login} no aaa logging {login} Parameters login—Enables logging messages related to successful AAA login events, unsuccessful AAA login events and other AAA login-related events. Default Configuration Logging of AAA login events is enabled. Command Mode Global Configuration mode User Guidelines This command enables logging messages related to successful login events, unsuccessful login events and other login-related events. Other types of AAA events are not subject to this command.272 Syslog Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables logging messages related to AAA login events. Console(config)# aaa logging login file-system logging Use the file-system logging Global Configuration mode command to enable the logging of file system events. Use the no form of this command to disable logging file system events. Syntax file-system logging {copy | delete-rename} no file-system logging {copy | delete-rename} Parameters • copy—Specifies logging messages related to file copy operations. • delete-rename—Specifies logging messages related to file deletion and renaming operations. Default Configuration Logging file system events is enabled. Command Mode Global Configuration mode Example The following example enables logging messages related to file copy operations. Console(config)# file-system logging copySyslog Commands 273 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY management logging Use the management logging Global Configuration mode command to enable logging Management Access List (ACL) deny events. Use the no form of this command to disable logging management access list events. Syntax management logging {deny} no management logging {deny} Parameters deny—Enables logging messages related to management ACL deny actions. Default Configuration Logging management ACL deny events is enabled. Command Mode Global Configuration mode User Guidelines Other management ACL events are not subject to this command. Example The following example enables logging messages related to management ACL deny actions. Console(config)# management logging deny show logging Use the show logging Privileged EXEC mode command to display the logging status and the syslog messages stored in the internal buffer. Syntax show logging274 Syslog Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Privileged EXEC mode Example The following example displays the logging status and the syslog messages stored in the internal buffer. console# show logging Logging is enabled. Console Logging: Level info. Console Messages: 0 Dropped. Buffer Logging: Level info. Buffer Messages: 61 Logged, 61 Displayed, 200 Max. File Logging: Level error. File Messages: 898 Logged, 64 Dropped. 4 messages were not logged Application filtering control Application Event Status -------------------- ---------------- --------- AAA Login Enabled File system Copy Enabled File system Delete-Rename Enabled Management ACL Deny Enabled Aggregation: Disabled. Aggregation aging time: 300 Sec 01-Jan-2010 05:29:46 :%INIT-I-Startup: Warm Startup 01-Jan-2010 05:29:02 :%LINK-I-Up: Vlan 1 01-Jan-2010 05:29:02 :%LINK-I-Up: gi1/0/48 01-Jan-2010 05:29:02 :%LINK-I-Up: gi1/0/47 01-Jan-2010 05:29:00 :%LINK-W-Down: gi1/0/48 show logging file Use the show logging file Privileged EXEC mode command to display the logging status and the syslog messages stored in the logging file.Syslog Commands 275 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show logging file Command Mode Privileged EXEC mode Example The following example displays the logging status and the syslog messages stored in the logging file. Logging is enabled. Console Logging: Level info. Console Messages: 0 Dropped. Buffer Logging: Level info. Buffer Messages: 61 Logged, 61 Displayed, 200 Max. File Logging: Level error. File Messages: 898 Logged, 64 Dropped. 4 messages were not logged Application filtering control Application Event Status ----------------- ---------------- --------- AAA Login Enabled File system Copy Enabled File system Delete-Rename Enabled Management ACL Deny Enabled Aggregation: Disabled. Aggregation aging time: 300 Sec 01-Jan-2010 05:57:00 :%SSHD-E-ERROR: SSH error: key_read: type mismatch: encoding error 01-Jan-2010 05:56:36 :%SSHD-E-ERROR: SSH error: key_read: type mismatch: encoding error 01-Jan-2010 05:55:37 :%SSHD-E-ERROR: SSH error: key_read: type mismatch: encoding error276 Syslog Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Syslog.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY 01-Jan-2010 05:55:03 :%SSHD-E-ERROR: SSH error: key_read: key_from_blob bgEgGnt9 z6NHgZwKI5xKqF7cBtdl1xmFgSEWuDhho5UedydAjVkKS5XR2... failed 01-Jan-2010 05:55:03 :%SSHD-E-ERROR: SSH error: key_from_blob: invalid key type. 01-Jan-2010 05:56:34 :%SSHD-E-ERROR: SSH error: bad sigbloblen 58 != SIGBLOB_LEN console# show syslog-servers Use the show syslog-servers Privileged EXEC mode command to display the syslog server settings. Syntax show syslog-servers Command Mode Privileged EXEC mode Example The following example displays the syslog server settings. console# show syslog-servers Device Configuration ----------------------------- IP address Port Severity Facility Description ------------- ---- --------- -------- -------------- 1.1.1.121 514 info local7 3000::100 514 info local7 console#RMON Commands 277 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 18 RMON Commands show rmon statistics Use the show rmon statistics EXEC mode command to display RMON Ethernet statistics. Syntax show rmon statistics {interface-id} Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode EXEC mode Example The following example displays RMON Ethernet statistics for gigabitethernet port 1/0/1. console# show rmon statistics gi1/0/1 Port gi1/0/1 Dropped: 0 Octets: 0 Packets: 0 Broadcast: 0 Multicast: 0 CRC Align Errors: 0 Collisions: 0 Undersize Pkts: 0 Oversize Pkts: 0 Fragments: 0 Jabbers: 0 64 Octets: 0 65 to 127 Octets: 1278 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY 128 to 255 Octets: 1 256 to 511 Octets: 1 512 to 1023 Octets: 0 1024 to max Octets: 0 The following table describes the significant fields displayed. Field Description Dropped The total number of events in which packets were dropped by the probe due to lack of resources. Note that this number is not necessarily the number of packets dropped. It is the number of times this condition was detected. Octets The total number of octets of data (including those in bad packets) received on the network (excluding framing bits but including FCS octets). Packets The total number of packets (including bad packets, broadcast packets, and multicast packets) received. Broadcast The total number of good packets received and directed to the broadcast address. This does not include multicast packets. Multicast The total number of good packets received and directed to a multicast address. This number does not include packets directed to the broadcast address. CRC Align Errors The total number of packets received with a length (excluding framing bits, but including FCS octets) of between 64 and 1518 octets, inclusive, but with either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a nonintegral number of octets (Alignment Error). Collisions The best estimate of the total number of collisions on this Ethernet segment. Undersize Pkts The total number of packets received, less than 64 octets long (excluding framing bits, but including FCS octets) and otherwise well formed. Oversize Pkts The total number of packets received, longer than 1518 octets (excluding framing bits, but including FCS octets) and otherwise well formed.RMON Commands 279 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY rmon collection stats Use the rmon collection stats Interface Configuration mode command to enable Remote Monitoring (RMON) MIB history group of statistics on an Fragments The total number of packets received, less than 64 octets in length (excluding framing bits but including FCS octets) and either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Jabbers The total number of packets received, longer than 1518 octets (excluding framing bits, but including FCS octets), and either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). 64 Octets The total number of packets (including bad packets) received that are 64 octets in length (excluding framing bits but including FCS octets). 65 to 127 Octets The total number of packets (including bad packets) received that are between 65 and 127 octets in length inclusive (excluding framing bits but including FCS octets). 128 to 255 Octets The total number of packets (including bad packets) received that are between 128 and 255 octets in length inclusive (excluding framing bits but including FCS octets). 256 to 511 Octets The total number of packets (including bad packets) received that are between 256 and 511 octets in length inclusive (excluding framing bits but including FCS octets). 512 to 1023 Octets The total number of packets (including bad packets) received that were between 512 and 1023 octets in length inclusive (excluding framing bits but including FCS octets). 1024 to max The total number of packets (including bad packets) received that were between 1024 octets and the maximum frame size in length inclusive (excluding framing bits but including FCS octets). Field Description 280 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY interface. Use the no form of this command to remove a specified RMON history group of statistics. Syntax rmon collection stats index [owner ownername] [buckets bucket-number] [interval seconds] no rmon collection stats index Parameters • index—The requested group of statistics index.(Range: 1–65535) • owner ownername—Records the name of the owner of the RMON group of statistics. If unspecified, the name is an empty string. (Range: Valid string) • buckets bucket-number—A value associated with the number of buckets specified for the RMON collection history group of statistics. If unspecified, defaults to 50.(Range: 1–50) • interval seconds—The number of seconds in each polling cycle. If unspecified, defaults to 1800 (Range: 1–3600). Command Mode Interface Configuration (Ethernet, Port-channel) mode. Cannot be configured for a range of interfaces (range context). show rmon collection stats Use the show rmon collection stats EXEC mode command to display the requested RMON history group statistics. Syntax show rmon collection stats [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel.RMON Commands 281 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode EXEC mode Example The following example displays all RMON history group statistics. The following table describes the significant fields shown in the display. show rmon history Use the show rmon history EXEC mode command to display RMON Ethernet history statistics. Syntax show rmon history index {throughput | errors | other} [period seconds] Parameters • index—Specifies the set of samples to display. (Range: 1–65535) • throughput—Displays throughput counters. Console# show rmon collection stats Index ----- 1 2 Interface --------- gi1/0/1 gi1/0/1 Interval -------- 30 1800 Requested Samples --------- 50 50 Granted Samples -------- 50 50 Owner ------- CLI Manager Field Description Index An index that uniquely identifies the entry. Interface The sampled Ethernet interface. Interval The interval in seconds between samples. Requested Samples The requested number of samples to be saved. Granted Samples The granted number of samples to be saved. Owner The entity that configured this entry.282 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • errors—Displays error counters. • other—Displays drop and collision counters. • period seconds—Specifies the period of time in seconds to display. (Range: 1–2147483647) Command Mode EXEC mode Example The following examples display RMON Ethernet history statistics for index 1 Console# show rmon history 1 throughput Sample Set: 1 Interface: gi1/0/1 Requested samples: 50 Owner: CLI Interval: 1800 Granted samples: 50 Maximum table size: 500 Time ------------ Jan 18 2005 21:57:00 Jan 18 2005 21:57:30 Octets ------- 303595962 287696304 Packets ------- 357568 275686 Broadcast -------- 3289 2789 Multicast --------- 7287 5878 Util ---- 19% 20% Console# show rmon history 1 errors Sample Set: 1 Interface:gi1/0/1 Requested samples: 50 Owner: Me Interval: 1800 Granted samples: 50 Maximum table size: 500 (800 after reset) Time ------------ Jan 18 2005 21:57:00 CRC Align ------- 1 Under size ----- 1 Oversize -------- 0 Fragments --------- 49 Jabbers ---- 0 Jan 18 2005 21:57:30 1 1 0 2 7 0RMON Commands 283 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes significant fields shown in the display: Console# show rmon history 1 other Sample Set: 1 Interface: gi1/0/1 Requested samples: 50 Owner: Me Interval: 1800 Granted samples: 50 Maximum table size: 500 Time ------------------- Jan 18 2005 21:57:00 Jan 18 2005 21:57:30 Dropped ------ 3 3 Collisions ---------- 0 0 Field Description Time Date and Time the entry is recorded. Octets The total number of octets of data (including those in bad packets and excluding framing bits but including FCS octets) received on the network. Packets The number of packets (including bad packets) received during this sampling interval. Broadcast The number of good packets received during this sampling interval that were directed to the broadcast address. Multicast The number of good packets received during this sampling interval that were directed to a multicast address. This number does not include packets addressed to the broadcast address. Utilization The best estimate of the mean physical layer network utilization on this interface during this sampling interval, in hundredths of a percent. CRC Align The number of packets received during this sampling interval that had a length (excluding framing bits but including FCS octets) between 64 and 1518 octets, inclusive, but had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Undersize The number of packets received during this sampling interval that were less than 64 octets long (excluding framing bits but including FCS octets) and were otherwise well formed.284 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY rmon alarm Use the rmon alarm Global Configuration mode command to configure alarm conditions. Use the no form of this command to remove an alarm. Syntax rmon alarm index mib-object-id interval rthreshold fthreshold revent fevent [type {absolute | delta}] [startup {rising | rising-falling | falling}] [owner name] no rmon alarm index Parameters • index—Specifies the alarm index. (Range: 1–65535) Oversize The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets) but were otherwise well formed. Fragments The total number of packets received during this sampling interval that were less than 64 octets in length (excluding framing bits but including FCS octets) and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error), or a bad FCS with a non-integral number of octets (Alignment Error). It is normal for etherHistoryFragments to increment because it counts both runts (which are normal occurrences due to collisions) and noise hits. Jabbers The number of packets received during this sampling interval that were longer than 1518 octets (excluding framing bits but including FCS octets), and had either a bad Frame Check Sequence (FCS) with an integral number of octets (FCS Error) or a bad FCS with a non-integral number of octets (Alignment Error). Dropped The total number of events in which packets were dropped by the probe due to lack of resources during this sampling interval. This number is not necessarily the number of packets dropped, it is the number of times this condition has been detected. Collisions The best estimate of the total number of collisions on this Ethernet segment during this sampling interval. Field Description RMON Commands 285 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • mib-object-id—Specifies the object identifier of the variable to be sampled. (Valid OID) • interval—Specifies the interval in seconds during which the data is sampled and compared with rising and falling thresholds. (Range: 1–4294967295) • rthreshold—Specifies the rising threshold value. (Range: 0–4294967295) • fthreshold—Specifies the falling threshold value. (Range: 0–4294967295) • revent—Specifies the index of the event triggered when a rising threshold is crossed. (Range: 0–65535) • fevent—Specifies the index of the event triggered when a falling threshold is crossed. (Range: 0–65535) • type {absolute | delta}—Specifies the method used for sampling the selected variable and calculating the value to be compared against the thresholds. The possible values are: • absolute—Specifies that the selected variable value is compared directly with the thresholds at the end of the sampling interval. • delta—Specifies that the selected variable value of the last sample is subtracted from the current value, and the difference is compared with the thresholds. • startup {rising | rising-falling | falling}—Specifies the alarm that may be sent when this entry becomes valid. The possible values are: • rising—Specifies that if the first sample (after this entry becomes valid) is greater than or equal to rthreshold, a single rising alarm is generated. • rising-falling—Specifies that if the first sample (after this entry becomes valid) is greater than or equal to rthreshold, a single rising alarm is generated. If the first sample (after this entry becomes valid) is less than or equal to fthreshold, a single falling alarm is generated. • fallin —Specifies that if the first sample (after this entry becomes valid) is less than or equal to fthreshold, a single falling alarm is generated. • owner name—Specifies the name of the person who configured this alarm. (Valid string)286 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The default method type is absolute. The default startup direction is rising-falling. If the owner name is not specified, it defaults to an empty string. Command Mode Global Configuration mode Example The following example configures an alarm with index 1000, MIB object ID D-Link, sampling interval 360000 seconds (100 hours), rising threshold value 1000000, falling threshold value 1000000, rising threshold event index 10, falling threshold event index 10, absolute method type and rising-falling alarm. console(config)# rmon alarm 1000 1.3.6.1.2.1.2.2.1.10.1 360000 1000000 1000000 10 20 show rmon alarm-table Use the show rmon alarm-table EXEC mode command to display a summary of the alarms table. Syntax show rmon alarm-table Command Mode EXEC modeRMON Commands 287 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the alarms table. The following table describes the significant fields shown in the display: show rmon alarm Use the show rmon alarm EXEC mode command to display alarm configuration. Syntax show rmon alarm number Parameters number—Specifies the alarm index. (Range: 1–65535) Command Mode EXEC mode Example The following example displays RMON 1 alarms. Console# show rmon alarm-table Index ----- 1 2 3 OID ---------------------- 1.3.6.1.2.1.2.2.1.10.1 1.3.6.1.2.1.2.2.1.10.1 1.3.6.1.2.1.2.2.1.10.9 Owner ------- CLI Manager CLI Field Description Index An index that uniquely identifies the entry. OID Monitored variable OID. Owner The entity that configured this entry.288 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Console# show rmon alarm 1 Alarm 1 ------- OID: 1.3.6.1.2.1.2.2.1.10.1 Last sample Value: 878128 Interval: 30 Sample Type: delta Startup Alarm: rising Rising Threshold: 8700000 Falling Threshold: 78 Rising Event: 1 Falling Event: 1 Owner: CLI The following table describes the significant fields shown in the display: Field Description Alarm Alarm index. OID Monitored variable OID. Last Sample Value The value of the statistic during the last sampling period. For example, if the sample type is delta, this value is the difference between the samples at the beginning and end of the period. If the sample type is absolute, this value is the sampled value at the end of the period. Interval The interval in seconds over which the data is sampled and compared with the rising and falling thresholds. Sample Type The method of sampling the variable and calculating the value compared against the thresholds. If the value is absolute, the variable value is compared directly with the thresholds at the end of the sampling interval. If the value is delta, the variable value at the last sample is subtracted from the current value, and the difference is compared with the thresholds.RMON Commands 289 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY rmon event Use the rmon event Global Configuration mode command to configure an event. Use the no form of this command to remove an event. Syntax rmon event index {none | log | trap | log-trap} [community text] [description text] [owner name] no rmon event index Parameters • index—Specifies the event index. (Range: 1–65535) • none— pecifies that no notification is generated by the device for this event. • log—Specifies that a notification entry is generated in the log table by the device for this event. Startup Alarm The alarm that may be sent when this entry is first set. If the first sample is greater than or equal to the rising threshold, and startup alarm is equal to rising or rising-falling, then a single rising alarm is generated. If the first sample is less than or equal to the falling threshold, and startup alarm is equal falling or rising-falling, then a single falling alarm is generated. Rising Threshold The sampled statistic rising threshold. When the current sampled value is greater than or equal to this threshold, and the value at the last sampling interval is less than this threshold, a single event is generated. Falling Threshold The sampled statistic falling threshold. When the current sampled value is less than or equal to this threshold, and the value at the last sampling interval is greater than this threshold, a single event is generated. Rising Event The event index used when a rising threshold is crossed. Falling Event The event index used when a falling threshold is crossed. Owner The entity that configured this entry. Field Description 290 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • trap—Specifies that an SNMP trap is sent to one or more management stations by the device for this event. • log-trap—Specifies that an entry is generated in the log table and an SNMP trap is sent to one or more management stations by the device for this event. • community text—Specifies the SNMP community to which an SNMP trap is sent. (Octet string; length: 0–127 characters) • description text—Specifies a comment describing this event. (Length: 0–127 characters) • owner name—Specifies the name of the person who configured this event. (Valid string) Default Configuration If the owner name is not specified, it defaults to an empty string. Command Mode Global Configuration mode Example The following example configures an event identified as index 10, for which the device generates a notification in the log table. Console(config)# rmon event 10 log show rmon events Use the show rmon events EXEC mode command to display the RMON event table. Syntax show rmon events Command Mode EXEC modeRMON Commands 291 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the RMON event table. The following table describes significant fields shown in the display: show rmon log Use the show rmon log EXEC mode command to display the RMON log table. Console# show rmon events Index ----- 1 Descrip tion -------- Errors Type ------ Log Community -------- Owner ------ CLI Last time sent -------- Jan18 2006 23:58:17 2 High Broadcast LogTrap Router Manager Jan18 2006 23:59:48 Field Description Index A unique index that identifies this event. Description A comment describing this event. Type The type of notification that the device generates about this event. Can have the following values: none, log, trap, log-trap. In the case of log, an entry is made in the log table for each event. In the case of trap, an SNMP trap is sent to one or more management stations. Community If an SNMP trap is to be sent, it is sent to the SNMP community specified by this octet string. Owner The entity that configured this event. Last time sent The time this entry last generated an event. If this entry has not generated any events, this value is zero.292 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show rmon log [event] Parameters event—Specifies the event index. (Range: 0–65535) Command Mode EXEC mode Example The following examples display the RMON log table. rmon table-size Use the rmon table-size Global Configuration mode command to configure the maximum size of RMON tables. Use the no form of this command to return to the default configuration. Syntax rmon table-size {history entries | log entries} no rmon table-size {history | log} Parameters • history entries—Specifies the maximum number of history table entries. (Range: 20–270) Console# show rmon log Maximum table size: 500 (800 after reset) Event ----- 1 Description -------------- MIB Var.: 1.3.6.1.2.1.2.2.1.10.53 , Delta, Rising, Actual Val: 800, Thres.Set: 100, Interval (sec):1 Time ------------------- Jan 18 2006 23:48:19 RMON Commands 293 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • log entries—Specifies the maximum number of log table entries. (Range: 20–100) Default Configuration The default history table size is 270 entries. The default log table size is 200 entries. Command Mode Global Configuration mode User Guidelines The configured table size takes effect after the device is rebooted. Example The following example configures the maximum size of RMON history tables to 100 entries. Console(config)# rmon table-size history 100294 RMON Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\RMON.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY802.1x Commands 295 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 19 802.1x Commands aaa authentication dot1x Use the aaa authentication dot1x Global Configuration mode command to specify one or more authentication, authorization, and accounting (AAA) methods for use on interfaces running IEEE 802.1x. Use the no form of this command to restore the default configuration. Syntax aaa authentication dot1x default method [method2 ...] no aaa authentication dot1x default Parameters method [method2 ...]—Specify at least one method from the following list: Default Configuration The default method is Radius. Command Mode Global Configuration mode User Guidelines Additional methods of authentication are used only if the previous method returns an error and not if the request for authentication is denied. Specify Keyword Description radius Uses the list of all RADIUS servers for authentication none Uses no authentication296 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY none as the final method in the command line to ensure that authentication succeeds even if all methods return an error. Example The following example uses the aaa authentication dot1x default command with no authentication. Console(config)# aaa authentication dot1x default none dot1x system-auth-control Use the dot1x system-auth-control Global Configuration mode command to enable 802.1x globally. Use the no form of this command to restore the default configuration. Syntax dot1x system-auth-control no dot1x system-auth-control Default Configuration All the ports are in FORCE_AUTHORIZED state. Command Mode Global Configuration mode Example The following example enables 802.1x globally. Console(config)# dot1x system-auth-control dot1x port-control Use the dot1x port-control Interface Configuration (Ethernet) mode command to enable manual control of the port authorization state. Use the no form of this command to restore the default configuration.802.1x Commands 297 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax dot1x port-control {auto | force-authorized | force-unauthorized} no dot1x port-control Parameters • auto—Enables 802.1x authentication on the interface and causes the port to transition to the authorized or unauthorized state based on the 802.1x authentication exchange between the device and the client. • force-authorized—Disables 802.1x authentication on the interface and causes the port to transition to the authorized state without any authentication exchange required. The port resends and receives normal traffic without 802.1x-based client authentication. • force-unauthorized—Denies all access through this interface by forcing the port to transition to the unauthorized state and ignoring all attempts by the client to authenticate. The device cannot provide authentication services to the client through the interface. Default Configuration The port is in the force-authorized state. Command Mode Interface Configuration (Ethernet) mode User Guidelines It is recommended to disable spanning tree or to enable spanning-tree PortFast mode on 802.1x edge ports (ports in auto state that are connected to end stations), in order to proceed to the forwarding state immediately after successful authentication. Example The following example enables 802.1x authentication on gigabitethernet port 1/0/15. Console(config)# interface gi1/0/15 Console(config-if)# dot1x port-control auto298 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY dot1x re-authentication Use the dot1x reauthentication Interface Configuration mode command to enable periodic re-authentication of the client. Use the no form of this command to return to the default setting. Syntax dot1x reauthentication no dot1x reauthentication Parameters This command has no arguments or keywords. Default Periodic re-authentication is disabled. Command Mode Interface configuration (Ethernet) Example console(config)# interface gi1/0/1 console(config-if)# dot1x reauthentication dot1x timeout reauth-period Use the dot1x timeout reauth-period Interface Configuration mode command to set the number of seconds between re-authentication attempts. Use the no form of this command to return to the default setting. Syntax dot1x timeout reauth-period seconds no dot1x timeout reauth-period802.1x Commands 299 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters seconds—Number of seconds between re-authentication attempts. (Range: 30–4294967295) Default 3600 Command Mode Interface Configuration (Ethernet) mode Example console(config)# interface gi1/0/1 console(config-if)# dot1x timeout reauth-period 5000 dot1x re-authenticate The dot1x re-authenticate Privileged EXEC mode command manually initiates re-authentication of all 802.1x-enabled ports or the specified 802.1xenabled port. Syntax dot1x re-authenticate [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode Example The following command manually initiates re-authentication of 802.1xenabled gigabitethernet port 1/0/15. Console# dot1x re-authenticate gi1/0/15300 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY dot1x timeout quiet-period Use the dot1x timeout quiet-period Interface Configuration (Ethernet) mode command to set the time interval that the device remains in a quiet state following a failed authentication exchange (for example, the client provided an invalid password). Use the no form of this command to restore the default configuration. Syntax dot1x timeout quiet-period seconds no dot1x timeout quiet-period Parameters seconds—Specifies the time interval in seconds that the device remains in a quiet state following a failed authentication exchange with the client. (Range: 0–65535 seconds) Default Configuration The default quiet period is 60 seconds. Command Mode Interface Configuration (Ethernet) mode User Guidelines During the quiet period, the device does not accept or initiate authentication requests. The default value of this command should only be changed to adjust to unusual circumstances, such as unreliable links or specific behavioral problems with certain clients and authentication servers. To provide faster response time to the user, a smaller number than the default value should be entered. Example The following example sets the time interval that the device remains in the quiet state following a failed authentication exchange to 3600 seconds.802.1x Commands 301 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Console(config)# interface gi1/0/15 Console(config-if)# dot1x timeout quiet-period 3600 dot1x timeout tx-period Use the dot1x timeout tx-period Interface Configuration (Ethernet) mode command to set the time interval during which the device waits for a response to an Extensible Authentication Protocol (EAP) request/identity frame from the client before resending the request. Use the no form of this command to restore the default configuration. Syntax dot1x timeout tx-period seconds no dot1x timeout tx-period Parameters seconds—Specifies the time interval in seconds during which the device waits for a response to an EAP-request/identity frame from the client before resending the request. (Range: 1–65535 seconds) Default Configuration The default timeout period is 30 seconds. Command Mode Interface Configuration (Ethernet) mode User Guidelines The default value of this command should be changed only to adjust to unusual circumstances, such as unreliable links or specific behavioral problems with certain clients and authentication servers. Example The following command sets the time interval during which the device waits for a response to an EAP request/identity frame to 3600 seconds. Console(config)# interface gi1/0/15 Console(config-if)# dot1x timeout tx-period 3600302 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY dot1x max-req Use the dot1x max-req Interface Configuration mode command to set the maximum number of times that the device sends an Extensible Authentication Protocol (EAP) request/identity frame (assuming that no response is received) to the client before restarting the authentication process. Use the no form of this command to restore the default configuration. Syntax dot1x max-req count no dot1x max-req Parameters count—Specifies the maximum number of times that the device sends an EAP request/identity frame before restarting the authentication process. (Range: 1–10) Default Configuration The default maximum number of attempts is 2. Command Mode Interface Configuration (Ethernet) mode User Guidelines The default value of this command should be changed only to adjust to unusual circumstances, such as unreliable links or specific behavioral problems with certain clients and authentication servers. Example The following example sets the maximum number of times that the device sends an EAP request/identity frame to 6 Console(config)# interface gi1/0/15 Console(config-if)# dot1x max-req 6802.1x Commands 303 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY dot1x timeout supp-timeout Use the dot1x timeout supp-timeout Interface Configuration (Ethernet) mode command to set the time interval during which the device waits for a response to an Extensible Authentication Protocol (EAP) request frame from the client before resending the request. Use the no form of this command to restore the default configuration. Syntax dot1x timeout supp-timeout seconds no dot1x timeout supp-timeout Parameters seconds—Specifies the time interval in seconds during which the device waits for a response to an EAP request frame from the client before resending the request. (Range: 1–65535 seconds) Default Configuration The default timeout period is 30 seconds. Command Mode Interface Configuration (Ethernet) mode User Guidelines The default value of this command should be changed only to adjust to unusual circumstances, such as unreliable links or specific behavioral problems with certain clients and authentication servers. Example The following example sets the time interval during which the device waits for a response to an EAP request frame from the client before resending the request to 3600 seconds. Console(config)# interface gi1/0/15 Console(config-if)# dot1x timeout supp-timeout 3600304 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY dot1x timeout server-timeout Use the dot1x timeout server-timeout Interface Configuration (Ethernet) mode command to set the time interval during which the device waits for a response from the authentication server. Use the no form of this command to restore the default configuration. Syntax dot1x timeout server-timeout seconds no dot1x timeout server-timeout Parameters seconds—Specifies the time interval in seconds during which the device waits for a response from the authentication server. (Range: 1–65535 seconds) Default Configuration The default timeout period is 30 seconds. Command Mode Interface Configuration (Ethernet) mode User Guidelines The actual timeout period can be determined by comparing the value specified by the dot1x timeout server-timeout command to the result of multiplying the number of retries specified by the radius-server retransmit command by the timeout period specified by the radius-server timeout command, and selecting the lower of the two values. Example The following example sets the time interval between retransmission of packets to the authentication server to 3600 seconds. Console(config)# interface gi1/0/15 Console(config-if)# dot1x timeout server-timeout 3600802.1x Commands 305 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show dot1x Use the show dot1x Privileged EXEC mode command to display the 802.1x device or specified interface status. Syntax show dot1x [interface interface-id] Parameters interface-id—Specify an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode Example The following examples display the status of 802.1x-enabled Ethernet ports. Console# show dot1x 802.1x is enabled Port ---- gi1/0/1 gi1/0/2 gi1/0/3 gi1/0/4 gi1/0/5 Admin Mode ---------- Auto Auto Auto Force-auth Force-auth Oper Mode ------------ Authorized Authorized Unauthorized Authorized Unauthorized Reauth Control ------- Ena Ena Ena Dis Dis Reauth Period ------ 3600 3600 3600 3600 3600 Username -------- Bob John Clark n/a n/a * Port is down or not present. Console# show dot1x interface gi1/0/3 802.1x is enabled.306 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes the significant fields shown in the display. Port ---- gi1/0/3 Admin Mode ---------- Auto Oper Mode ------------ Unauthorized Reauth Control ------- Enable Reauth Period ------ 3600 Username -------- Clark Quiet period: Tx period: Max req: Supplicant timeout: 60 Seconds 30 Seconds 2 30 Seconds Server timeout: Session Time (HH:MM:SS): MAC Address: Authentication Method: Termination Cause: 30 Seconds 08:19:17 00:08:78:32:98:78 Remote Supplicant logoff Authenticator State Machine State: HELD Backend State Machine State: Authentication success: Authentication fails: IDLE 9 1 Field Description Port The port number. Admin mode The port admin mode. Possible values: Force-auth, Force-unauth, Auto. Oper mode The port oper mode. Possible values: Authorized, Unauthorized or Down. Reauth Control Reauthentication control. Reauth Period Reauthentication period.802.1x Commands 307 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Username The username representing the supplicant identity. This field shows the username if the port control is auto. If the port is Authorized, it displays the username of the current user. If the port is Unauthorized, it displays the last user authenticated successfully. Quiet period The number of seconds that the device remains in the quiet state following a failed authentication exchange (for example, the client provided an invalid password). Tx period The number of seconds that the device waits for a response to an Extensible Authentication Protocol (EAP) request/identity frame from the client before resending the request. Max req The maximum number of times that the device sends an EAP request frame (assuming that no response is received) to the client before restarting the authentication process. Supplicant timeout The number of seconds that the device waits for a response to an EAP-request frame from the client before resending the request. Server timeout The number of seconds that the device waits for a response from the authentication server before resending the request. Session Time The amount of time (HH:MM:SS) that the user is logged in. MAC address The supplicant MAC address. Authentication Method The authentication method used to establish the session. Termination Cause The reason for the session termination. State The current value of the Authenticator PAE state machine and of the Backend state machine. Authentication success The number of times the state machine received a Success message from the Authentication Server. Authentication fails The number of times the state machine received a Failure message from the Authentication Server. Field Description308 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show dot1x users Use the show dot1x users Privileged EXEC mode command to display active 802.1x authenticated users for the device. Syntax show dot1x users [username username] Parameters username—Specifies the supplicant username (Length: 1–160 characters) Command Mode Privileged EXEC mode802.1x Commands 309 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays 802.1x users. Switch# show dot1x users Port Username Session Auth MAC VLAN Filter Time Method Address ------ ---------- ------------- -------- ------------- ---- ---- gi1/0/1 Bob 1d 03:08:58 Remote 0008.3b79.8787 3 gi1/0/2 John 08:19:17 None 0008.3b89.3127 2 OK Port Username Session Auth MAC VLAN Filter Time Method Address --------- ------------------------------ ----------- ---- ------ gi1/0/1 Bob 1d 09:07:38 Remote 0008.3b79.8787 3 OK gi1/0/1 Bernie 03:08:58 Remote 0008.3b79.3232 9 OK gi1/0/2 John 08:19:17 Remote 0008.3b89.3127 2 gi1/0/3 Paul 02:12:48 Remote 0008.3b89.8237 8 Warning Switch# show dot1x users username Bob Port Username Session Auth MAC VLAN Filter Time Method Address --------- ------------------------------ ----------- ---- ----- gi1/0/1 Bob 1d 09:07:38 Remote 0008.3b79.8787 3 OK Filter ID #1: Supplicant-IPv4 Filter ID #2: Supplicant-IPv6 Switch# show dot1x users username Bernie Port Username Session Auth MAC VLAN Filter Time Method Address --------- ------------------------------ ----------- ---- ----- gi1/0/1 Bernard 03:08:58 Remote 0008.3b79.3232 9 OK Filter ID #1: Supplicant-IPv4310 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show dot1x statistics Use the show dot1x statistics Privileged EXEC mode command to display 802.1x statistics for the specified interface. Syntax show dot1x statistics interface interface-id Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode Example The following example displays 802.1x statistics for gigabitethernet port 1/0/1. Console# show dot1x statistics interface gi1/0/1 EapolFramesRx: 11 EapolFramesTx: 12 EapolStartFramesRx: 1 EapolLogoffFramesRx: 1 EapolRespIdFramesRx: 3 EapolRespFramesRx: 6 EapolReqIdFramesTx: 3 EapolReqFramesTx: 6 InvalidEapolFramesRx: 0 EapLengthErrorFramesRx: 0 LastEapolFrameVersion: 1 LastEapolFrameSource: 00:08:78:32:98:78802.1x Commands 311 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes the significant fields shown in the display: clear dot1x statistics Use the clear dot1x statistics Privileged EXEC mode command to clear 802.1x statistics. Field Description EapolFramesRx The number of valid EAPOL frames of any type that have been received by this Authenticator. EapolFramesTx The number of EAPOL frames of any type that have been transmitted by this Authenticator. EapolStartFramesRx The number of EAPOL Start frames that have been received by this Authenticator. EapolLogoffFramesRx The number of EAPOL Logoff frames that have been received by this Authenticator. EapolRespIdFramesRx The number of EAP Resp/Id frames that have been received by this Authenticator. EapolRespFramesRx The number of valid EAP Response frames (other than Resp/Id frames) that have been received by this Authenticator. EapolReqIdFramesTx The number of EAP Req/Id frames that have been transmitted by this Authenticator. EapolReqFramesTx The number of EAP Request frames (other than Req/Id frames) that have been transmitted by this Authenticator. InvalidEapolFramesRx The number of EAPOL frames that have been received by this Authenticator for which the frame type is not recognized. EapLengthErrorFramesR x The number of EAPOL frames that have been received by this Authenticator in which the Packet Body Length field is invalid. LastEapolFrameVersion The protocol version number carried in the most recently received EAPOL frame. LastEapolFrameSource The source MAC address carried in the most recently received EAPOL frame.312 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax clear dot1x statistics [interface-id] Parameters interface-id—Specify an Ethernet port ID. Default Configuration Statistics on all ports are cleared. Command Mode Privileged EXEC mode Example The following example displays how to clear 802.1x statistics on all ports Console# clear dot1x statistics dot1x auth-not-req Use the dot1x auth-not-req Interface Configuration (VLAN) mode command to enable unauthorized devices access to the VLAN. Use the no form of this command to disable access to the VLAN. Syntax dot1x auth-not-req no dot1x auth-not-req Default Configuration Access is enabled. Command Mode Interface Configuration (VLAN) mode User Guidelines An access port cannot be a member in an unauthenticated VLAN. The native VLAN of a trunk port cannot be an unauthenticated VLAN.802.1x Commands 313 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY For a general port, the PVID can be an unauthenticated VLAN (although only tagged packets are accepted in the unauthorized state). Example The following example enables unauthorized devices access to VLAN 5. Console(config)# interface vlan 5 Console(config-if)# dot1x auth-not-req dot1x host-mode Use the dot1x host-mode Interface Configuration mode command to allow a single host (client) or multiple hosts on an IEEE 802.1x-authorized port. Use the no form of this command to return to the default setting. Syntax dot1x host-mode {multi-host | single-host | multi-sessions} Parameters • multi-host—Enable multiple-hosts mode. • single-host—Enable single-hosts mode. • multi-sessions—Enable multiple-sessions mode. Default Default mode is multi-host. Command Mode Interface Configuration (Ethernet) mode User Guidelines In multiple hosts mode only one of the attached hosts must be successfully authorized for all hosts to be granted network access. If the port becomes unauthorized, all attached clients are denied access to the network. In multiple sessions mode each host must be successfully authorized in order to grant network access. Please note that packets are NOT encrypted, and 314 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY after success full authentication filtering is based on the source MAC address only. Port security on a port can’t be enabled in single-host mode and in multiplesessions mode. It is recommended to enable reauthentication when working in multiplesessions mode in order to detect User Logout for users that hadn’t sent Logoff. Example console(config)# interface gi1/0/1 console(config-if)# dot1x host-mode multi-host console(config-if)# dot1x host-mode single-host console(config-if)# dot1x host-mode multi-sessions dot1x violation-mode Use the dot1x violation-mode Interface Configuration (Ethernet) mode command to configure the action to be taken, when a station whose MAC address is not the supplicant MAC address, attempts to access the interface. Use the no form of this command to return to default. Syntax dot1x violation-mode {restrict | protect | shutdown} no dot1x violation-mode Parameters • restrict—Generates a trap when a station whose MAC address is not the supplicant MAC address, attempts to access the interface. The minimum time between the traps is 1 second. Those frames are forwarded but their source address are not learned. • protect—Discard frames with source addresses not the supplicant address. • shutdown—Discard frames with source addresses not the supplicant address and shutdown the port802.1x Commands 315 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration Protect Command Mode Interface Configuration (Ethernet) mode User Guidelines The command is relevant for single-host mode. The command is not relevant for multiple-hosts mode. The command is relevant for multiple-sessions mode, but you should note that since PCs are sending traffic prior to successful 802.1X authentication, this command might not be useful in this mode. BPDU message whose MAC address is not the supplicant MAC address wouldn’t be discarded in the protect mode. BPDU message whose MAC address is not the supplicant MAC address would cause a shutdown in the shutdown mode. Example console(config)# interface gigabitethernet gi1/0/1 console(config-if)# dot1x violation-mode protect dot1x guest-vlan Use the dot1x guest-vlan Interface Configuration (VLAN) mode command to define a guest VLAN. Use the no form of this command to restore the default configuration. Syntax dot1x guest-vlan no dot1x guest-vlan Default Configuration No VLAN is defined as a guest VLAN.316 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Interface Configuration (VLAN) mode User Guidelines Use the dot1x guest-vlan enable Interface Configuration mode command to enable unauthorized users on an interface to access the guest VLAN. If the guest VLAN is defined and enabled, the port automatically joins the guest VLAN when the port is unauthorized and leaves it when the port becomes authorized. To be able to join or leave the guest VLAN, the port should not be a static member of the guest VLAN. Example The following example defines VLAN 2 as a guest VLAN. Console# configure Console(config)# interface vlan 2 Console(config-if)# dot1x guest-vlan dot1x guest-vlan timeout Use the dot1x guest-vlan timeout Global Configuration mode command to set the time delay between enabling 802.1x (or port up) and adding a port to the guest VLAN. Use the no form of this command to restore the default configuration. Syntax dot1x guest-vlan timeout timeout no dot1x guest-vlan timeout Parameters timeout—Specifies the time delay in seconds between enabling 802.1x (or port up) and adding the port to the guest VLAN. (Range: 30–180) Default Configuration The guest VLAN is applied immediately.802.1x Commands 317 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode User Guidelines This command is relevant if the guest VLAN is enabled on the port. Configuring the timeout adds delay from enabling 802.1X (or port up) to the time the device adds the port to the guest VLAN. Example The following example sets the delay between enabling 802.1x and adding a port to a guest VLAN to 60 seconds. Console(config)# dot1x guest-vlan timeout 60 dot1x guest-vlan enable Use the dot1x guest-vlan enable Interface Configuration (Ethernet) mode command to enable unauthorized users on the interface access to the guest VLAN. Use the no form of this command to disable access. Syntax dot1x guest-vlan enable no dot1x guest-vlan enable Default Configuration The default configuration is disabled. Command Mode Interface Configuration (Ethernet) mode User Guidelines A device can have only one global guest VLAN. The guest VLAN is defined using the dot1x guest-vlan Interface Configuration mode command.318 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables unauthorized users on gigabitethernet port 1/0/1 to access the guest VLAN. Console(config)# interface gi1/0/15 Console(config-if)# dot1x guest-vlan enable dot1x mac-authentication Use the dot1x mac-authentication Interface Configuration (Ethernet) mode command to enable authentication based on the station’s MAC address. Use the no form of this command to disable access. Syntax dot1x mac-authentication {mac-only | mac-and-802.1x} no dot1x mac-authentication Parameters • mac-only—Enables authentication based on the station's MAC address only. 802.1X frames are ignored. • mac-and-802.1x—Enables 802.1X authentication and MAC address authentication on the interface. Default Configuration Authentication based on the station's MAC address is disabled. Command Mode Interface Configuration (Ethernet) mode User Guidelines The guest VLAN must be enabled when MAC authentication is enabled. Static MAC addresses cannot be authorized. Do not change an authenticated MAC address to a static address. It is not recommended to delete authenticated MAC addresses. Reauthentication must be enabled when working in this mode.802.1x Commands 319 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables authentication based on the station’s MAC address on gigabitethernet port 1/0/1. Console(config)# interface gi1/0/1 Console(config-if)# dot1x mac-authentication mac-only dot1x traps mac-authentication success Use the dot1x traps mac-authentication success Global Configuration mode command to enable sending traps when a MAC address is successfully authenticated by the 802.1X mac-authentication access control. Use the no form of this command to disable the traps. Syntax dot1x traps mac-authentication success no dot1x traps mac-authentication success Parameters This command has no arguments or keywords. Default Default is disabled. Command Mode Global Configuration mode dot1x traps mac-authentication failure Use the dot1x traps mac-authentication failure Global Configuration mode command to enable sending traps when MAC address was failed in authentication of the 802.1X MAC authentication access control. Use the no form of this command to disable the traps.320 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax dot1x traps mac-authentication failure no dot1x traps mac-authentication failure Parameters This command has no arguments or keywords. Default Default is disabled. Command Mode Global Configuration mode dot1x radius-attributes vlan Use the dot1x radius-attributes vlan Interface Configuration mode command, to enable user-based VLAN assignment. Use the no form of this command to disable user-based VLAN assignment. Syntax dot1x radius-attributes vlan no dot1x radius-attributes vlan Parameters This command has no arguments or keywords. Default Disabled Command Mode Interface Configuration (Ethernet) mode User Guidelines The configuration of this command is allowed only when the port is Forced Authorized.802.1x Commands 321 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Radius attributes are supported only in the multiple sessions mode (multiple hosts with authentication) When Radius attributes are enabled and the Radius Accept message does not contain the supplicant’s VLAN as an attribute, then the supplicant is rejected. Packets to the supplicant are sent untagged. After successful authentication the port remains member in the unauthenticated VLANs and in the Guest VLAN. Other static VLAN configuration is not applied on the port. If the supplicant VLAN does not exist on the switch, the supplicant is rejected. Example console(config)# interface gi1/0/1 console(config-if)# dot1x radius-attributes vlan dot1x radius-attributes filter-id Use the dot1x radius-attributes filter-id Interface Configuration mode command to enable user-based ACL/Qos-Policy assignment. Use the no form of this command to disable user-based ACL/Qos-Policy assignment. Syntax dot1x radius-attributes filter-id no dot1x radius-attributes filter-id Parameters This command has no arguments or keywords. Default Disabled Command Mode Interface Configuration (Ethernet) mode322 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines User based ACL/Qos-Policy assignment is supported only in 802.1x multiple sessions. The configuration of the parameter is allowed only when the port is Forced Authorized or Forced Unauthorized. dot1x radius-attributes errors Use the dot1x radius-attributes errors Global Configuration mode command to specify error handling for the Radius attributes feature. Use the no form of this command to return to default. Syntax dot1x radius-attributes errors filter-id resources {accept | reject} no dot1x radius-attributes errors filter-id resources Parameters accept—If the Filter-ID cannot be allocated for resource allocation reasons, the user is accepted. If the Filter-ID canot be allocated for other reasons, the user is rejected. reject—If the Filter-ID cannot be assigned, the user is rejected. Default Reject Command Mode Global Configuration mode dot1x legacy-supp-mode Use the dot1x legacy-supp-mode Interface Configuration mode command in multiple session mode to enable 802.1x switch to send a periodic EAPOL request identity frame according to tx timeout period in order to verify authentication in multiple session mode of clients that do not follow 802.1x standard behavior. Use the no form of this command to return to the default setting.802.1x Commands 323 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax dot1x legacy-supp-mode no dot1x legacy-supp-mode Parameters This command has no arguments or keywords. Default Legacy support is disabled. Command Mode Interface Configuration (Ethernet) mode User Guidelines The command causes 802.1x switch to send an Extensible Authentication Protocol (EAP)-request/identity frame from the authenticator (switch) each tx-period automatically, when in multiple session mode. The command should be activated onlywhen all devices connected to that port do not follow 802.1x standard behavior to send EAPOL start packets when the client link goes up (for example, some Windows OS with pre Service Pack 3). show dot1x advanced Use the show dot1x advanced Privileged EXEC mode command to display 802.1x advanced features for the device or specified interface. Syntax show dot1x advanced [interface-id] Parameters nterface-id—Specify an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode324 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays 802.1x advanced features for the device. dot1x system-auth-control monitor Use the dot1x system-auth-control monitor Global Configuration command to enable 802.1x globally the 802.1x Monitoring mode and define the Monitor VLAN. Use the no format of the command to return to default. Syntax dot1x system-auth-control monitor [vlan vlan-id] no dot1x system-auth-control monitor console# show dot1x advanced Guest VLAN: 3978 Unauthenticated VLANs: 91, 92 Interface Multiple Guest MAC VLAN Legacy- Policy Hosts VLAN Authentication Assignment supp Mode Assignment ------------------ ---------------------- ----------- --------- ------ gi1/0/1 Disabled Enabled MAC-and-802.1X Enabled Enable Disabled gi1/0/2 Enabled Disabled Disabled Enabled Enable Disabled Switch# show dot1x advanced gi1/0/1 Interface Multiple Guest MAC VLAN Legacy- Policy Hosts VLAN Authentication Assignment sup Mode Assignment ------------------ ----------------------- ----------- ------ ------- gi1/0/1 Disabled Enabled MAC-and-802.1X Enabled Enable Legacy-Supp mode is disabled Policy assignment resource err handling: Accept Single host parameters Violation action: Discard Trap: Enabledx Status: Single-host locked Violations since last trap: 9802.1x Commands 325 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters vlan vlan-id—Specifies the 802.1x Monitoring VLAN. If the parameter is omitted, the Default VLAN is used as the 802.1x Monitoring VLAN.(Range: Any manually created VLAN or the Default VLAN) Default Disabled Command Mode Global Configuration mode User Guidelines The 802.1x Monitoring VLAN cannot be deleted manually. show dot1x monitoring result Use the show dot1x monitoring result Privileged EXEC mode command to display the captured information of each interface/host on the switch/stack. Syntax show dot1x monitoring result [username username] Parameters username username—Specifies supplicant username (Range: 1–80 characters) Command Mode Privileged EXEC mode User Guidelines The following table describes the significant fields shown in the display: Field Description Usernamr Supplicant Username VLAN VLAN assigned to Supplicant MAC address Supplicant MAC address326 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Port Ethernet port or port-channel Reject reason Reason in the case of failure. The following table describes the reasons. Time Supplicant Session time Table 1: Reject Reason Description Abbreviation Description ACL-DEL ACL was deleted by a user ACL-NOTEXST ACL sent by radius Server does not exist on the device ACL-OVRFL ACL sent by radius server can not be applied because of TCAM overflow AUTH-ERR Rejected by Radius due wrong user name or password in Radius server FLTR-ERR Radius accept message contains more than 2 filter-id FRS-MTH-DENY First method is "deny" IPv6WithMAC Radius accept message contains filter with IPv6 DIP and MAC addresses IPV6WithNotIP Radius accept message contains IPv6 and not IP simultaneously POL-BasicMode Policy Map is not supported in the QoS basic mode POL-DEL Policy Map was deleted by a user POL-OVRFL Policy Map sent by radius server can not be applied because of TCAM overflow RAD-APIERR RADIUS API returned error (e.g. No RADIUS server is configured). RAD_INVLRES RADIUS server returned invalid packet (e.g. EAP Attribute is missing) RAD-NORESP RADIUS server is not responding VLAN-DFLT VLAN sent by radius server can not be applied because it is the Default VLAN802.1x Commands 327 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Examples Example 1 Switch# show dot1x monitoring results Monitoring VLAN: 100 Port VLAN UsernameMAC Reject Time Address Reason --------- --------------------------- ---------- --------- gi1/0/1 100 Bob 0008.3b79.8787 VLAN-NOTEX08:19:17 gi1/0/2 15 John 0008.3b89.3128 SERV-ERR 09:20:11 gi1/0/2 5 John 0008.3b89.3129 SERV-ERR 09:20:11 Example 2 Switch# show dot1x monitoring Bob Username: Bob Port gi1/0/1 Quiet period: 60 Seconds Tx period: 30 Seconds Max req: 2 Supplicant timeout: 30 Seconds Server timeout: 30 Seconds Session Time (HH:MM:SS): 08:19:17 MAC Address: 00:08:78:32:98:78 Authentication Method: Remote Assigned VLAN: 207 Reason for Failure: Radius server rejected authentication because username/password mismatch Example 3 VLAN-DYNAM VLAN sent by radius server can not be applied because it is a Dynamic VLAN VLAN-GUEST VLAN sent by radius server can not be applied because it is the Guest VLAN Table 1: Reject Reason Description328 802.1x Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\802.1X.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Switch# show dot1x monitoring Tom Username: Tom Port gi1/0/1 Quiet period: 60 Seconds Tx period: 30 Seconds Max req: 2 Supplicant timeout: 30 Seconds Server timeout: 30 Seconds Session Time (HH:MM:SS): 08:19:17 MAC Address: 00:08:78:32:98:78 Authentication Method: Remote Assigned VLAN: 207 Reason for Failure:VLAN was not defined on SwitchEthernet Configuration Commands 329 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 20 Ethernet Configuration Commands interface Use the interface Global Configuration mode command to configure an interface and enter interface configuration mode. Syntax interface interface-id Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. interface range Use the interface range command to execute a command on multiple ports at the same time. Syntax interface range interface-id-list Parameters interface-id-list—Specify list of interface IDs. The interface ID can be one of the following types: Ethernet port or Port-channel User Guidelines Commands under the interface range context are executed independently on each interface in the range: If the command returns an error on one of the interfaces, it does not stop the execution of the command on other interfaces.330 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example console(config)# interface range gi1/0/1-20 description Use the description Interface Configuration (Ethernet, Port-channel) mode command to add a description to an interface. Use the no form of this command to remove the description. Syntax description string no description Parameters string—Specifies a comment or a description of the port to assist the user. (Length: 1–64 characters) Default Configuration The interface does not have a description. Command Mode Interface Configuration (Ethernet, Port-channel) mode Example The following example adds the description ‘SW#3’ to gigabitethernet port 1/0/5. Console(config)# interface gi1/0/5 Console(config-if)# description SW#3 speed Use the speed Interface Configuration (Ethernet, Port-channel) mode command to configure the speed of a given Ethernet interface when not Ethernet Configuration Commands 331 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY using auto-negotiation. Use the no form of this command to restore the default configuration. Syntax speed {10 | 100 | 1000 | 10000} no speed Parameters • 10—Forces10 Mbps operation. • 100—Forces 100 Mbps operation. • 1000—Forces 1000 Mbps operation. • 10000—Forces 10000 Mbps operation. Default Configuration The port operates at its maximum speed capability. Command Mode Interface Configuration (Ethernet, Port-channel) mode User Guidelines The no speed command in a Port-channel context returns each port in the Port-channel to its maximum capability. Example The following example configures the speed of gigabitethernet port 1/0/5 to 100 Mbps operation. Console(config)# interface gi1/0/5 Console(config-if)# speed 100 duplex Use the duplex Interface Configuration (Ethernet, Port-channel) mode command to configure the full/half duplex operation of a given Ethernet interface when not using auto-negotiation. Use the no form of this command to restore the default configuration.332 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax duplex {half | full} no duplex Parameters • half—Forces half-duplex operation. • full—Forces full-duplex operation. Default Configuration The interface operates in full duplex mode. Command Mode Interface Configuration (Port-channel) mode Example The following example configures gigabitethernet port 1/0/5 to operate in full duplex mode. Console(config)# interface gi1/0/5 Console(config-if)# duplex full Console(config-if)# negotiation Use the negotiation Interface Configuration (Ethernet, Port-channel) mode command to enable auto-negotiation operation for the speed and duplex parameters and master-slave mode of a given interface, where the preferred default mode is master mode. Use the no form of this command to disable auto-negotiation. Syntax negotiation [capability [capability2 ... capability5]] [preferred {master | slave}] no negotiationEthernet Configuration Commands 333 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • capability—Specifies the capabilities to advertise. (Possible values: 10h, 10f, 100h,100f, 1000f). If unspecified, defaults to list of all the capabilities of the port. • Preferred—Specifies the master-slave preference: • Master—Advertise master preference • Slave—Advertise slave preference Default Configuration Auto-negotiation is enabled and preferred default mode is master mode. Command Mode Interface Configuration (Ethernet, Port-channel) mode Example The following example enables auto-negotiation on gigabitethernet port 1/0/5. Console(config)# interface gi1/0/5 Console(config-if)# negotiation Console(config-if)# flowcontrol Use the flowcontrol Interface Configuration (Ethernet, Port-channel) mode command to configure the Flow Control on a given interface. Use the no form of this command to disable Flow Control. Syntax flowcontrol {auto | on | off} no flowcontrol Parameters • aut—Specifies auto-negotiation. • on—Enables Flow Control.334 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • off—Disables Flow Control. Default Configuration Flow control is enabled. Command Mode Interface Configuration (Ethernet, Port-channel) mode User Guidelines Use the negotiation command to enable flow control auto. Example The following example enables Flow Control on port gi1/0/1 Console(config)# interface gi1/0/1 Console(config-if)# flowcontrol on flowcontrol (Global) Use the flowcontrol Global Configuration mode command to configure the Flow Control global mode. Syntax flowcontrol {receive-only | send-receive} Parameters • receive-only—The interfaces with enabled Flow Control will receive pause frames, but will not send Flow Control pause frames. • send-receive—The interfaces with enabled Flow Control will receive and send pause frames. Default Configuration receive-only. Command Mode Global Configuration modeEthernet Configuration Commands 335 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines This command only determines the global mode and does not enable/disable Flow Control on any interface. Flowcontrol must also be enabled on the specific interfaces required (they are enabled by default). Example The following example enables Flow Control in the mode of only receiving pause frames and not sending them. Console(config)# flowcontrol receive-only show flowcontrol Use the show flowcontrol Exec mode command to display the Flow Control global mode. Syntax show flowcontrol Parameters N/A Default Configuration N/A Command Mode Exec mode Example The following example displays the global Flow Control mode when it is receiveonly. Console# show flowcontrol Global Flow Control mode is receive-only.336 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY mdix Use the mdix Interface Configuration (Ethernet) mode command to enable cable crossover on a given interface. Use the no form of this command to disable cable crossover. Syntax mdix {on | auto} no mdix Parameters • on—Enables manual MDIX. • auto—Enables automatic MDI/MDIX. Default Configuration The default setting is On. Command Mode Interface Configuration (Ethernet) mode Example The following example enables automatic crossover on port 1/5. Console(config)# interface gi1/0/1/5 Console(config-if)# mdix auto. The following example enables automatic crossover on port gigabitethernet 1/0/1. Console(config)# interface gi1/0/5 Console(config-if)# mdix autoEthernet Configuration Commands 337 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY back-pressure Use the back-pressure Interface Configuration (Ethernet) mode command to enable back pressure on a specific interface. Use the no form of this command to disable back pressure. Syntax back-pressure no back-pressure Default Configuration Back pressure is enabled. Command Mode Interface Configuration (Ethernet) mode Example The following example enables back pressure on port gi1/0/5. Console(config)# interface gi1/0/5 Console(config-if)# back-pressure port jumbo-frame Use the port jumbo-frame Global Configuration mode command to enable jumbo frames on the device. Use the no form of this command to disable jumbo frames. Syntax port jumbo-frame no port jumbo-frame Default Configuration Jumbo frames are disabled on the device.338 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode User Guidelines This command takes effect only after resetting the device. Example The following example enables jumbo frames on the device. Console(config)# port jumbo-frame clear counters Use the show interfaces counters EXEC mode command to display traffic seen by all the physical interfaces or by a specific interface. Syntax show interfaces counters [interface-id] [detailed] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. detailed—Displays information for non-present ports in addition to present ports. Command Mode EXEC mode Example The following example clears the statistics counters for gigabitethernet port 1/0/5. Console# clear counters gi1/0/5.Ethernet Configuration Commands 339 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY set interface active Use the set interface active EXEC mode command to reactivate an interface that was shut down. Syntax set interface active { interface-id } Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode EXEC mode User Guidelines This command is used to activate interfaces that were configured to be active, but were shut down by the system. Example The following example reactivates gigabitethernet port 1/0/1. Console# set interface active gi1/0/1 show interfaces configuration Use the show interfaces configuration EXEC mode command to display the configuration for all configured interfaces or for a specific interface. Syntax show interfaces configuration [interface-id ] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel.340 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode EXEC mode Example The following example displays the configuration of all configured interfaces: console# show interfaces configuration Flow Admin Back Mdix Port Type Duplex Speed Neg control State Pressure Mode ------ --------- ------ ----- -------- ------- ----- -------- - gi1/0/1 1G-Copper Full 10000 Disabled Off Up Disabled Off gi1/0/2 1G-Copper Full 1000 Disabled Off Up Disabled Off Flow Admin Ch Type Speed Neg Control State ------ ------ ----- -------- ------- ----- Po1 Disabled Off Up show interfaces status Use the show interfaces status EXEC mode command to display the status of all configured interfaces or of a specific interface. Syntax show interfaces status [interface-id][detailed] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. detailed—Displays information for non-present ports in addition to present ports. Command Mode EXEC modeEthernet Configuration Commands 341 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the status of all configured interfaces. console# show interfaces status Flow Link Back Mdix Port Type Duplex Speed Neg ctrl State Pressure Mode ------ --------- ------ ----- -------- ---- ------ -------- -- gi1/0/1 1G-Copper Full 1000 Disabled Off Up Disabled Off gi1/0/2 1G-Copper -- -- -- -- Down -- -- Flow Link Ch Type Duplex Speed Neg ctrl State ----- ------- ------ ----- ------- ---- ------ Po1 1G Full 10000 Disabled Off Up show interfaces advertise Use the show interfaces advertise EXEC mode command to display autonegotiation advertisement information for all configured interfaces or for a specific interface. Syntax show interfaces advertise [interface-id | Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode EXEC mode342 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Examples The following examples display auto-negotiation information. show interfaces description Use the show interfaces description EXEC mode command to display the description for all configured interfaces or for a specific interface. Syntax show interfaces description [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Console# show interfaces advertise Port ---- gi1/0/1 gi1/0/2 Type ---------- 1G-Copper 1G-Copper Neg ------ Enable Enable Operational Link Advertisement ------------------------------ 1000f, 100f, 10f, 10h 1000f Console# show interfaces advertise gi1/0/1 Port:gi1/0/1 Type: 1G-Copper Link state: Up Auto Negotiation: enabled Admin Local link Advertisement Oper Local link Advertisement Remote Local link Advertisement Priority Resolution 10h --- yes yes no - 10f --- yes yes no - 100 h --- - yes yes yes - 100f ---- yes yes yes - 1000f ----- yes yes yes yes Console# show interfaces advertise gi1/0/1 Port: gi1/0/1 Type: 1G-Copper Link state: Up Auto negotiation: disabled.Ethernet Configuration Commands 343 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode EXEC mode Example The following example displays the description of all configured interfaces. show interfaces counters Use the show interfaces counters EXEC mode command to display traffic seen by all the physical interfaces or by a specific interface. Syntax show interfaces counters [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode EXEC mode Console# show interfaces description Port gi1/0/1 gi1/0/1 gi1/0/2 gi1/0/1 gi1/0/1 gi1/0/2 Descriptions --------------------------------------------- Port that should be used for management only Ch ---- Po1 Description ----------- Output344 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays traffic seen by all the physical interfaces. console# show interfaces counters Port InUcastPkts InMcastPkts InBcastPkts InOctets ---------- ------------ ------------ ------------ ------------ gi1/0/1 0 0 0 0 Port OutUcastPkts OutMcastPkts OutBcastPkts OutOctets ---------- ------------ ------------ ------------ ------------ gi1/0/1 0 1 35 7051 Alignment Errors: 0 FCS Errors: 0 Single Collision Frames: 0 Multiple Collision Frames: 0 SQE Test Errors: 0 Deferred Transmissions: 0 Late Collisions: 0 Excessive Collisions: 0 Carrier Sense Errors: 0 Oversize Packets: 0 Internal MAC Rx Errors: 0 Symbol Errors: 0 Received Pause Frames: 0 Transmitted Pause Frames: 0Ethernet Configuration Commands 345 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes the fields shown in the display. Field Description InOctets The number of received octets. InUcastPkts The number of received unicast packets. InMcastPkts The number of received multicast packets. InBcastPkts The number of received broadcast packets. OutOctets The number of transmitted octets. OutUcastPkts The number of transmitted unicast packets. OutMcastPkts The number of transmitted multicast packets. OutBcastPkts The number of transmitted broadcast packets. FCS Errors The number of frames received that are an integral number of octets in length but do not pass the FCS check. Single Collision Frames The number of frames that are involved in a single collision, and are subsequently transmitted successfully. Multiple Collision Frames The number of frames that are involved in more than one collision and are subsequently transmitted successfully. SQE Test Errors The number of times that the SQE TEST ERROR is received. The SQE TEST ERROR is set in accordance with the rules for verification of the SQE detection mechanism in the PLS Carrier Sense Function as described in IEEE Std. 802.3, 2000 Edition, section 7.2.4.6. Deferred Transmissions The number of frames for which the first transmission attempt is delayed because the medium is busy. Late Collisions The number of times that a collision is detected later than one slotTime into the transmission of a packet. Excessive Collisions The number of frames for which transmission fails due to excessive collisions. Oversize Packets The number of frames received that exceed the maximum permitted frame size.346 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show port jumbo-frame Use the show port jumbo-frame EXEC mode command to display the configuration of jumbo frames. Syntax show port jumbo-frame Command Mode EXEC mode Example The following example displays the configuration of jumbo frames on the device. Console# show port jumbo-frame Jumbo frames are disabled Jumbo frames will be enabled after reset show errdisable interfaces Use the show errdisable interfaces EXEC mode command to display the ErrDisable state of all interfaces or of a specific interface. Internal MAC Rx Errors The number of frames for which reception fails due to an internal MAC sublayer receive error. Received Pause Frames The number of MAC Control frames received with an opcode indicating the PAUSE operation. Transmitted Pause Frames The number of MAC Control frames transmitted on this interface with an opcode indicating the PAUSE operation. Field DescriptionEthernet Configuration Commands 347 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show errdisable interfaces Parameters • Interface - Interface number • port-channel-number - Port channel index. Command Mode EXEC mode Example The following example displays the Err-Disable state of all interfaces. Console# show errdisable interfaces Interface Reason --------- -------------- gi1/1/50 stp-bpdu-guard storm-control broadcast enable Use the storm-control broadcast enable Interface Configuration mode command to enable storm control. Use the no form of this command to disable storm control. Syntax storm-control broadcast enable no storm-control broadcast enable Parameters This command has no arguments or keywords. Default Configuration Disabled348 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Interface Configuration mode(Ethernet) User Guidelines • Use the storm-control broadcast level Interface Configuration command to set the maximum rate. • Use the storm-control include-multicast Interface Configuration command to also count multicast packets and optionally unknown unicast packets in the storm control calculation. • Example console(config)# interface gi1/0/1 console(config-if)# storm-control broadcast enable storm-control broadcast level kbps Use the storm-control broadcast levelInterface Configuration mode command to configure the maximum rate of broadcast. Use the no form of this command to return to default. Syntax storm-control broadcast level kbps kbps no storm-control broadcast level Parameters kbps—Maximum of kilo bits per second of broadcast traffic on a port. (Range: GE: 3.5M–1G, 10GE: 8.5M–10G) Default Configuration 1000 Command Mode Interface Configuration mode (Ethernet)Ethernet Configuration Commands 349 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines Use the storm-control broadcast enable Interface Configuration command to enable storm control. The calculated rate includes the 20 bytes of Ethernet framing overhead (preamble+SFD+IPG). Example console(config)# interface gi1/0/1 console(config-if)# storm-control broadcast level kbps 12345 storm-control include-multicast Use the storm-control include-multicast Interface Configuration mode command to count multicast packets in the broadcast storm control. Use the no form of this command to disable counting of multicast packets in the broadcast storm control. Syntax storm-control include-multicast no storm-control include-multicast Parameters Default Configuration Disabled Command Mode Interface Configuration mode (Ethernet) User Guidelines Example console(config)# interface gi1/0/1 console(config-if)# storm-control include-multicast350 Ethernet Configuration Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show storm-control Use the show storm-control EXEC mode command to display the configuration of storm control. Syntax show storm-control [interface-id ] Parameters interface-id—Specifies the interface. Command Mode EXEC mode Example console# show storm-control Port State Rate [Kbits/Sec] Included ------ -------- --------------- ------------------------ gi1/0/1 Enabled 12345 Broadcast, Multicast, Unknown unicast gi1/0/2 Disabled 100000 Broadcast User Guidelines Use the storm-control broadcast enable Interface Configuration command to enable storm control. The calculated rate includes the 20 bytes of Ethernet framing overhead (preamble+SFD+IPG). If the suppression level in percentage is translated (for the current port’s speed) to a rate that is lower then the minimum rate, the minimum rate would be set. Example console(config)# interface gi1/0/1 console(config-if)# storm-control broadcast level kbps 12345PHY Diagnostics Commands 351 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Phy_Diagnostics.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 21 PHY Diagnostics Commands test cable-diagnostics tdr Use the test cable-diagnostics tdr Privileged EXEC mode command to use Time Domain Reflectometry (TDR) technology to diagnose the quality and characteristics of a copper cable attached to a port. Syntax test cable-diagnostics tdr interface interface-id Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode User Guidelines The port to be tested should be shut down during the test, unless it is a combination port with fiber port active. The maximum length of cable for the TDR test is 120 meters. Example The following examples test the copper cables attached to ports 7 and 8. Console# test cable-diagnostics tdr interface gi1/0/7 Cable is open at 64 meters Console# test cable-diagnostics tdr interface gi1/0/8352 PHY Diagnostics Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Phy_Diagnostics.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Can't perform the test on fiber ports show cable-diagnostics tdr Use the show cable-diagnostics tdr EXEC mode command to display information on the last Time Domain Reflectometry (TDR) test performed on all copper ports or on a specific copper port. Syntax show cable-diagnostics tdr [interface interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode EXEC mode User Guidelines The maximum length of cable for the TDR test is 120 meters. Example The following example displays information on the last TDR test performed on all copper ports. Console> show cable-diagnostics tdr Port ---- Result --------- Length [meters] -------------- Date --------------------- gi1/0/1 OK gi1/0/2 Short 50 13:32:00 23 July 2010 gi1/0/3 Test has not been performed gi1/0/4 Open 64 13:32:00 23 July 2010 gi1/0/5 Fiber - -PHY Diagnostics Commands 353 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Phy_Diagnostics.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show cable-diagnostics cable-length Use the show cable-diagnostics cable-length EXEC mode command to display the estimated copper cable length attached to all ports or to a specific port. Syntax show cable-diagnostics cable-length [interface interface-id] Parameters interface-id—Specify an interface ID. The interface ID must be an Ethernet port. Command Mode EXEC mode User Guidelines The port must be active and working at 100 M or 1000 M. Example The following example displays the estimated copper cable length attached to all ports. show fiber-ports optical-transceiver Use the show fiber-ports optical-transceiver EXEC mode command to display the optical transceiver diagnostics. Console> show cable-diagnostics cable-length Port ---- gi1/0/1 gi1/0/2 gi1/0/3 gi1/0/4 Length [meters] ----------------- < 50 Copper not active 110-140 Fiber354 PHY Diagnostics Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Phy_Diagnostics.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show fiber-ports optical-transceiver [interface interface-id] [detailed] Parameters • interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. • detailed—Displays detailed diagnostics. Command Mode EXEC mode Example The following examples display the optical transceiver diagnostics results. console# show fiber-ports optical-transceiver Port Temp Voltage Current Output Input LOS Power Power ----------- ------ ------- ------- ------ ----- --- gi1/0/1 W OK OK OK OK OK gi1/0/2 OK OK OK E OK OK Temp - Internally measured transceiver temperature Voltage - Internally measured supply voltage Current - Measured TX bias current Output Power - Measured TX output power in milliWatts Input Power - Measured RX received power in milliWatts LOS - Loss of signal N/A - Not Available, N/S - Not Supported, W - Warning, E - ErrorPHY Diagnostics Commands 355 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Phy_Diagnostics.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY console# show fiber-ports optical-transceiver detailed Port Temp Voltage Current Output Input LOS [C] [Volt] [mA] Power Power [mWatt] [mWatt] ----------- ------ ------- ------- ------- ------- --- gi0/1 Copper gi0/26 Copper gi0/27 28 3.32 7.26 3.53 3.68 No gi0/28 29 3.33 6.50 3.53 3.71 No Temp - Internally measured transceiver temperature Voltage - Internally measured supply voltage Current - Measured TX bias current Output Power - Measured TX output power in milliWatts Input Power - Measured RX received power in milliWatts LOS - Loss of signal N/A - Not Available, N/S - Not Supported, W - Warning, E - Error356 PHY Diagnostics Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Phy_Diagnostics.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYPower over Ethernet (PoE) Commands 357 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 22 Power over Ethernet (PoE) Commands power inline Use the power inline Interface Configuration mode command to configure the inline power administrative mode on an interface. Syntax power inline {auto | never} Parameters • auto—Turns on the device discovery protocol and applies power to the device. • never—Turns off the device discovery protocol and stops supplying power to the device. Default Configuration The default configuration is set to auto. Command Mode Interface Configuration (Ethernet) mode Example The following example turns on the device discovery protocol on port 4. Console(config)# interface gi1/0/4 Console(config-if)# power inline auto358 Power over Ethernet (PoE) Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY power inline limit-mode Use the power inline limit-mode Global Configuration mode command to set the power limit mode of the system. Use the no form of this command to return to the default. Syntax power inline limit-mode { port | max-port-power } no power inline limit-mode Parameters • port—The power limit of a port depends on port configuration • max-port-power—In this mode, each port can get up to the maximum power, which is 15.4W. Command Mode Global Configuration mode Default User Guidelines Changing the PoE limit mode of the system turns the power OFF and ON for all PoE ports. Example The following example sets the power limit to port. switchxxxxxx(config)# power inline limit-mode portPower over Ethernet (PoE) Commands 359 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY power inline powered-device Use the power inline powered-device Interface Configuration mode command to add a description of the powered device type. Use the no form of this command to remove the description. Syntax power inline powered-device pd-type no power inline powered-device Parameters pd-type—Enters a comment or a description to assist in recognizing the type of the powered device attached to this interface. (Length: 1–24 characters) Default Configuration There is no description. Command Mode Interface Configuration (Ethernet) mode Example The following example adds the description ‘ip phone’ of the device connected to port 4. Console(config)# interfacegi1/0/4 Console(config-if)# power inline powered-device ip phone power inline priority Use the power inline priority Interface Configuration (Ethernet) mode command to configure the interface inline power management priority. Use the no form of this command to restore the default configuration. Syntax power inline priority {critical | high | low}360 Power over Ethernet (PoE) Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY no power inline priority Parameters • critical—Specifies that the powered device operation is critical. • high—Specifies that the powered device operation is high priority. • low—Specifies that the powered device operation is low priority. Default Configuration The default configuration is set to low priority. Command Mode Interface Configuration (Ethernet) mode Example The following example sets the inline power management priority of gigabitethernet port 4 to High. Console(config)# interface gi1/0/4 Console(config-if)# power inline priority high power inline usage-threshold Use the power inline usage-threshold Global Configuration mode command to configure the threshold for initiating inline power usage alarms. Use the no form of this command to restore the default configuration. Syntax power inline usage-threshold percent no power inline usage-threshold Parameters percent—Specifies the threshold in percent to compare to the measured power. (Range: 1–99) Default Configuration The default threshold is 95 percent.Power over Ethernet (PoE) Commands 361 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode Example The following example configures the threshold for initiating inline power usage alarms to 90 percent. Console(config)# power inline usage-threshold 90 power inline traps enable Use the power inline traps enable Global Configuration mode command to enable inline power traps. Use the no form of this command to disable traps. Syntax power inline traps enable no power inline traps enable Default Configuration Inline power traps are disabled. Command Mode Global Configuration mode Example The following example enables inline power traps. Console(config)# power inline traps enable power inline limit Use the power inline limit Interface Configuration mode command to configure the power limit per port on an interface. Use the no form of the command to return to default. 362 Power over Ethernet (PoE) Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax power inline limit power no power inline limit Parameters power—States the port power consumption limit in Milliwatts (Range: 0- 15400 Default Configuration The default value is the maximum power allowed in the specific working mode: • 15.4W Command Mode Interface Configuration (Ethernet) mode Example The following example sets inline power on a port. console(config)# interface gi1/0/1 console(config-if)# power inline limit 2222 show power inline Use the show power inline EXEC mode command to display information about the inline power for all interfaces or for a specific interface. Syntax show power inline [interface-id | module stack-member-number] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. stack-member-number—Specifies the switch member in a stack.Power over Ethernet (PoE) Commands 363 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration There is no default configuration for this command. Command Mode EXEC mode Example 1: The following example displays information about the inline power. console(config)# show power inline Port based power-limit mode Unit Power Nominal Consumed Usage Traps Power Power Threshold ---- ------- ------- ------- ------ -------- 1 On 500 Watts 100 Watts (20%) 95 Disable 2 Off 1 Watts 0 Watts (0%) 95 Disable 3 Off 1 Watts 0 Watts (0%) 95 Disable 4 Off 1 Watts 0 Watts (0%) 95 Disable 5 Off 1 Watts 0 Watts (0%) 95 Disable 6 Off 1 Watts 0 Watts (0%) 95 Disable 7 Off 1 Watts 0 Watts (0%) 95 Disable 8 Off 1 Watts 0 Watts (0%) 95 Disable Port Powered Device State Status Priority Class ----- -------------- ----------- -------- -------- ------- gi1/0/1 IP Phone Model A Auto On High Class0 gi1/0/2 Wireless AP Model A Auto On Low Class1 gi1/0/3 Auto Off Low N/A ... Example 2: The following example displays information about the inline power for a specific port. console(config)# show power inline gi1/1/1 Port Powered Device State Status Priority Class 364 Power over Ethernet (PoE) Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY ----- -------------- ------- ------ -------- ------- gi1/1/1 IP Phone Model A Auto On High Class0 Power limit (for port power-limit mode): 15.4W Overload Counter: 0 Short Counter: 0 Denied Counter: 0 Absent Counter: 0 Invalid Signature Counter: 0 The following table describes the fields shown in the display: Field Description Power The inline power sourcing equipment operational status. Nominal Power The inline power sourcing equipment nominal power in Watts. Consumed Power The measured usage power in Watts. Usage Threshold The usage threshold expressed in percent for comparing the measured power and initiating an alarm if threshold is exceeded. Traps Indicates if inline power traps are enabled. Port The Ethernet port number. Powered device A description of the powered device type. Admin State Indicates if the port is enabled to provide power. The possible values are Auto or Never. Priority The port inline power management priority. The possible values are Critical, High or Low. Oper State Describes the port inline power operational state. The possible values are On, Off, Test-Fail, Testing, Searching or Fault. Classification The power consumption classification of the powered device. Overload Counter Counts the number of overload conditions detected. Short Counter Counts the number of short conditions detected. Denied Counter Counts the number of times power was denied.Power over Ethernet (PoE) Commands 365 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes the fields shown in the display: Following is a list of port status values: Port is on - valid capacitor detected Port is on - valid resistor detected Port is off - main supply voltage is high Port is off - main supply voltage is low Port is off -‘disable all ports’ pin is active Port is off - non-existing port number Fewer ports are available than the max. Port is off - Port is yet undefined Port is off - internal hardware fault Port is off - user setting Port is off - detection is in process Port is off - non-802.3af powered device Port is off - Overload & Underload states Port is off – Underload state Port is off – Overload state Port is off - power budget exceeded Port is off - internal hardware fault Port is off – voltage injection into the port Port is off - improper Capacitor Detection results Port is off - discharged load Port fails Capacitor Port is on – detection regardless (Force On) Undefined error during Force On Supply voltage higher than settings Supply voltage lower than settings Disable_PDU flag raised during Force On Port is forced on, then disabled Port is off – forced power error due to Overload Absent Counter Counts the number of times power was removed because powered device dropout was detected. Invalid Signature Counter Counts the number of times an invalid signature of a powered device was detected. Field Description366 Power over Ethernet (PoE) Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Port is off - “out of power budget” during Force On Communication error with PoE devices after Force On Port is off – short condition Port is off – over temperature at the port Port is off – device is too hot Unknown device port status Force Power Error Short Circuit Force Power Error Channel Over Temperature Force Power Error Chip Over Temperature Power Management-Static Power Management-Static -ovl Force Power Error Management Static Force Power Error Management Static -ovl High power port is ON Chip Over Power Force Power Error Chip Over Power show power inline consumption Use the show power inline consumption EXEC mode command to display information about the inline power consumption for all interfaces or for a specific interface. Syntax show power inline consumption [interface-id | module stack-membernumber] Parameters Interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. stack-member-number—Specifies the switch member in a stack. Default Configuration There is no default configuration for this command.Power over Ethernet (PoE) Commands 367 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode EXEC mode Example The following example displays information about the inline power consumption. show power inline version Use the show power inline version EXEC mode command to display the power inline microcontroller's software version for all the stacking units or for a specific unit. Syntax show power inline version [unit unit] Parameters unit unit — Specifies the stacking unit number. Default Configuration There is no default configuration for this command. Command Mode EXEC mode Console# show power inline consumption Port ---- gi1/0/1 gi1/0/1 gi1/0/1 Power Limit (W) ---------- 15.4 15.4 15.4 Power (W) ---------- 4.115 4.157 4.021 Voltage (V) --------- 50.8 50.7 50.9 Current (mA) --------- 81 82 79368 Power over Ethernet (PoE) Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\PoE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays information about the inline power consumption. Console# show power inline version Unit ---- 1 2 Software version ---------------- 1.12 1.12EEE Commands 369 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_EEE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 23 EEE Commands eee enable (global) Use the eee enable Global Configuration command to enable the EEE mode globally. Use the no format of the command to disable the mode. Syntax eee enable no eee enable Default Configuration EEE is enabled. Command Mode Global Configuration mide User Guidelines Since EEE uses the Auto-Negotiation to negotiate the EEE support on both sides of the link, if Auto-Negotiation is not enabled on the port, the EEE Operational status is disabled. eee enable (interface) Use the eee enable Interface Configuration command to enable the EEE mode on an Ethernet port. Use the no format of the command to disable the mode. Syntax eee enable370 EEE Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_EEE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY no eee enable Default Configuration EEE is enabled. Command Mode Interface Configuration mode (Ethernet) User Guidelines Since EEE uses the Auto-Negotiation to negotiate the EEE support on both sides of the link, if Auto-Negotiation is not enabled on the port, the EEE Operational status is disabled. eee lldp enable Use the eee lldp enable Interface Configuration command to enable EEE support by LLDP on an Ethernet port. Use the no format of the command to disable the support. Syntax eee lldp enable no eee lldp enable Default Configuration Enabled Command Mode Interface Configuration mode (Ethernet) User Guidelines Enabling EEE LLDP advertisement allows devices to choose and change system wake-up times in order to get the optimal energy saving mode. show eee Use the show eee EXEC command to display EEE information.EEE Commands 371 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_EEE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show eee [interface-id] Parameters interface-id—Specify an interface ID. The interface ID must be an Ethernet port. Command Mode EXEC Examples Example 1. Brief Information about all ports Switch>show eee EEE globally enabled EEE Administrate status is enabled on ports: gi1/0/1-6,gi1/0/12 EEE Operational status is enabled on ports: gi1/0/1,gi1/0/3- 6,gi1/0/12,gi1/0/15 EEE LLDP Administrate status is enabled on ports: gi1/0/1-10 EEE LLDP Operational status is enabled on ports: gi1/0/3-5 Example 2. Port in state notPresent, no information if port supports EEE Switch> show eee gi1/0/10 Port Status: notPresent EEE Administrate status: enabled EEE LLDP Administrate status: enabled EEE LLDP Administrate status: enabled Example 3. Port in status DOWN Switch>show eee gi1/0/10 Port Status: DOWN EEE capabilities: Speed 10M: EEE not supported372 EEE Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_EEE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Speed 100M: EEE supported Speed 1G: EEE supported Speed 10G: EEE not supported EEE Administrate status: enabled EEE LLDP Administrate status: enabled Example 4. Port in status UP and does not support EEE Switch>show eee gi1/0/20 Port Status: UP EEE capabilities: Speed 10M: EEE not supported Speed 100M: EEE supported Speed 1G: EEE supported Speed 10G: EEE not supported Current port speed: 1Gbps EEE Administrate status: enabled EEE LLDP Administrate status: enabled Example 5. Neighbor does not support EEE Switch>show eee gi1/0/15 Port Status: UP EEE capabilities: Speed 10M: EEE not supported Speed 100M: EEE supported Speed 1G: EEE supported Speed 10G: EEE not supported Current port speed: 1Gbps EEE Remote status: disabled EEE Administrate status: enabled EEE Operational status: disabled (neighbor does not support) EEE LLDP Administrate status: enabledEEE Commands 373 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_EEE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY EEE LLDP Operational status: disabled Example 6. EEE is disabled on the port Switch>show eee gi1/0/10 Port Status: UP EEE capabilities: Speed 10M: EEE not supported Speed 100M: EEE supported Speed 1G: EEE supported Speed 10G: EEE not supported Current port speed: 1Gbps EEE Administrate status: disabled EEE Operational status: disabled EEE LLDP Administrate status: enabled EEE LLDP Operational status: disabled Example 7. EEE is running on the port, EEE LLDP is disabled Switch>show eee gi1/0/12 Port Status: UP EEE capabilities: Speed 10M: EEE not supported Speed 100M: EEE supported Speed 1G: EEE supported Speed 10G: EEE not supported Current port speed: 1Gbps EEE Remote status: enabled EEE Administrate status: enabled EEE Operational status: enabled EEE LLDP Administrate status: disabled EEE LLDP Operational status: disabled Resolved Tx Timer: 10usec374 EEE Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_EEE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Local Tx Timer: 10 usec Resolved Timer: 25 usec Local Rx Timer: 20 usec Example 8. EEE and EEE LLDP are running on the port Switch>show eee gi1/0/3 Port Status: UP EEE capabilities: Speed 10M: EEE not supported Speed 100M: EEE supported Speed 1G: EEE supported Speed 10G: EEE not supported Current port speed: 1Gbps EEE Remote status: enabled EEE Administrate status: enabled EEE Operational status: enabled EEE LLDP Administrate status: enabled EEE LLDP Operational status: enabled Resolved Tx Timer: 10usec Local Tx Timer: 10 usec Remote Rx Timer: 5 usec Resolved Timer: 25 usec Local Rx Timer: 20 usec Remote Tx Timer: 25 usec Example 9. EEE is running on the port, EEE LLDP enabled but not synchronized with remote link partner Switch>show eee gi1/0/9 Port Status: up EEE capabilities: Speed 10M: EEE not supported Speed 100M: EEE supportedEEE Commands 375 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_EEE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Speed 1G: EEE supported Speed 10G: EEE not supported Current port speed: 1Gbps EEE Remote status: enabled EEE Administrate status: enabled EEE Operational status: enabled EEE LLDP Administrate status: enabled EEE LLDP Operational status: disabled Resolved Tx Timer: 64 Local Tx Timer: 64 Resolved Rx Timer: 16 Local Rx Timer: 16 Example 10. EEE and EEE LLDP are running on the port Switch>show eee gi1/0/3 Port Status: UP EEE capabilities: Speed 10M: EEE not supported Speed 100M: EEE supported Speed 1G: EEE supported Speed 10G: EEE not supported Current port speed: 1Gbps EEE Remote status: enabled EEE Administrate status: enabled EEE Operational status: enabled EEE LLDP Administrate status: enabled EEE LLDP Operational status: enabled Resolved Tx Timer: 10usec Local Tx Timer: 10 usec Remote Rx Timer: 5 usec Resolved Timer: 25 usec376 EEE Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_EEE.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Local Rx Timer: 20 usec Remote Tx Timer: 25 usecGreen Ethernet 377 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Green_Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 24 Green Ethernet show green-ethernet Use the show green-ethernet Privileged EXEC mode command to show green-ethernet configuration and information. Syntax show green-ethernet [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Parameters Range Default. When no interface is specified, this command shows information for all interfaces. Command Mode Privileged EXEC mode User Guidelines The following describes all possible reasons the show command displays, and their descriptions. If there are a several reasons for non-operation, then only the highest priority reason is displayed. Energy-detect Non-operational Reasons priority Reason Description378 Green Ethernet FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Green_Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example console# show green-ethernet Energy-Detect mode: Enabled Short-Reach mode: Disabled Power Consumption: 76% (3.31W out of maximum 4.33W) Cumulative Energy Saved: 33 [Watt*Hour] Short-Reach cable length threshold: 50m Port Energy-Detect Short-Reach VCT Cable Admin Oper Reason Admin Force Oper Reason Length ---- ----- ---- ------- ----- ----- ---- ------- ------ gi1/0/1 on on off off off gi1/0/2 on off LU on off off < 50 gi1/0/3 on off LU off off off 1 NP Port is not present 2 LT Link Type is not supported (fiber, auto media select) 3 LU Port Link is up – NA Short-Reach Non-operational Reasons Priority Reason Description 1 NP Port is not present 2 LT Link Type is not supported (fiber) 3 LS Link Speed Is not Supported (100M,10M,10G) 4 LL Link Length received from VCT Test exceed threshold 6 LD Port Link is Down – NA Green Ethernet 379 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Green_Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY green-ethernet short-reach (global) Use the green-ethernet short-reach Global Configuration mode command to enable green-ethernet short-reach mode globally. Use the no form of this command to disabled it. Syntax green-ethernet short-reach no green-ethernet short-reach Parameters This command has no arguments or keywords. Default Configuration EEE is enabled. Command Mode Global Configuration mode Example console(config)# green-ethernet short-reach green-ethernet short-reach (interface) Use the green-ethernet short-reach Interface Configuration mode command to enable green-ethernet short-reach mode on an interface. Use the no form of this command to disable it on an interface. Syntax green-ethernet short-reach no green-ethernet short-reach Parameters This command has no arguments or keywords.380 Green Ethernet FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Green_Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration EEE is enabled. Command Mode Interface Configuration mode (Ethernet) User Guidelines When short-reach Mode is enabled and is not forced, the VCT (Virtual Cable Tester) length check must be performed. The VCT length check can be performed only on a copper port operating at a speed of 1000 Mbps. If the media is not copper or the link speed is not 1000 Mbps and short-reach mode is not forced (by green-ethernet short-reach force), short-reach mode is not applied. When the interface is set to enhanced mode, after the VCT length check has completed and set the power to low, an active monitoring for errors is done continuously. In the case of errors crossing a certain threshold, the PHY will be reverted to long reach. Example console(config)# interface gi1/0/1 console(config-if)# green-ethernet short-reach green-ethernet short-reach force Use the green-ethernet short-reach force Interface Configuration mode command to force short-reach mode on an interface. Use the no form of this command to return to default. Syntax green-ethernet short-reach force no green-ethernet short-reach force Parameters This command has no arguments or keywords.Green Ethernet 381 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Green_Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration Short-reach mode is not forced. Command Mode Interface Configuration mode(Ethernet) Example console(config)# interface gi1/0/1 console(config-if)# green-ethernet short-reach force green-ethernet short-reach threshold Use the green-ethernet short-reach threshold Global Configuration mode command to set the maximum cable length for applying short-reach. Use the no form of this command to return to default. Syntax green-ethernet short-reach threshold cable-length no green-ethernet short-reach threshold Parameters cable-length—Specifies the maximum cable length (in meters) measured by VCT that allows applying short-reach mode (cable-length 0–70 meters) Default Configuration The default length is 40 meters. Command Mode Global Configuration mode User Guidelines Note that the automatic cable length measurement accuracy is +-10 meters. i.e. a cable with a real length of 30 m may be evaluated in the range of 20m–40m. Length performance depends on the link partner signal quality, cable quality and whether link partner also operates in short-reach mode.382 Green Ethernet FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_Green_Ethernet.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY The recommended default is 50m, as recommended by Marvell PHY team for any cable type. see appendix However, Marvell tests show that link partner can operate error free with an up to 80 m cable (cat 5e). The user may choose to change the threshold parameter under certain circumstances. Setting the threshold to 0 meters basically results in the short reach feature always being disabled, because the threshold will always be exceeded. green-ethernet power-meter reset Use the green-ethernet power meter reset Privileged EXEC mode command to reset the power save meter. Syntax green-ethernet power-meter reset Command Mode Privileged EXEC mode.Port Channel Commands 383 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Port_Channel.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 25 Port Channel Commands channel-group Use the channel-group Interface Configuration (Ethernet) mode command to associate a port with a port-channel. Use the no form of this command to remove a port from a port-channel. Syntax channel-group port-channel mode {on | auto} no channel-group Parameters • port-channel—Specifies the port channel number for the current port to join. • mode {on | auto}—Specifies the mode of joining the port channel. The possible values are: • on—Forces the port to join a channel without an LACP operation. • auto—Forces the port to join a channel as a result of an LACP operation. Default Configuration The port is not assigned to a port-channel. Command Mode Interface Configuration (Ethernet) mode384 Port Channel Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Port_Channel.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example forces port gi1/0/1 to join port-channel 1 without an LACP operation. Console(config)# interface gi1/0/1 Console(config-if)# channel-group 1 mode on port-channel load-balance Use the port-channel load-balance Global Configuration mode command to configure the load balancing policy of the port channeling. Use the no form of this command to reset to default. Syntax port-channel load-balance {src-dst-mac | src-dst-ip | src-dst-mac-ip | } no port-channel load-balance Parameters • src-dst-mac—Port channel load balancing is based on the source and destination MAC address. • src-dst-ip—Port channel load balancing is based on the source and destination IP address. • src-dst-mac-ip—Port channel load balancing is based on the source and destination of MAC and IP addresses. Default Configuration src-dst-mac is the default option. Command Mode Global Configuration mode User Guidelines In src-dst-mac-ip-port load balancing policy, fragmented packets might be reordered.Port Channel Commands 385 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Port_Channel.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example console# console# configure console(config)# port-channel load-balance src-dst-mac console(config)# port-channel load-balance src-dst-ip console(config)# port-channel load-balance src-dst-mac-ip console(config)# port-channel load-balance src-dst-mac-ip-port console(config)# show interfaces port-channel Use the show interfaces port-channel EXEC mode command to display portchannel information for all port channels or for a specific port channel. Syntax show interfaces port-channel [interface-id] Parameters interface-id—Specify an interface ID. The interface ID must be a Port Channel. Command Mode EXEC mode Example The following example displays information on all port-channels. console# console# show interfaces port-channel Load balancing: src-dst-mac. Gathering information... Channel Ports ------- ----- Po1 Active: gi1/0/1,Inactive: gi1/0/2-3 Po2 Active: gi1/0/25 Inactive: gi1/0/24386 Port Channel Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Port_Channel.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Po3 console# show interfaces switchport gi1/0/10 Gathering information... Name: gi1/0/10 Switchport: enable Administrative Mode: access Operational Mode: down Access Mode VLAN: 1 Access Multicast TV VLAN: none Trunking Native Mode VLAN: 1 Trunking VLANs Enabled: 1 2-4094 (Inactive) General PVID: 1 General VLANs Enabled: none General Egress Tagged VLANs Enabled: none General Forbidden VLANs: none General Ingress Filtering: enabled General Acceptable Frame Type: all General GVRP status: disabled Customer Mode VLAN: none Private-vlan promiscuous-association primary VLAN: none Private-vlan promiscuous-association Secondary VLANs Enabled: none Private-vlan host-association primary VLAN: none Private-vlan host-association Secondary VLAN Enabled: none DVA: disableAddress Table Commands 387 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 26 Address Table Commands bridge multicast filtering Use the bridge multicast filtering Global Configuration mode command to enable the filtering of multicast addresses. Use the no form of this command to disable multicast address filtering. Syntax bridge multicast filtering no bridge multicast filtering Default Configuration Multicast address filtering is disabled. All multicast addresses are flooded to all ports. Command Mode Global Configuration mode User Guidelines If multicast devices exist on the VLAN, do not change the unregistered multicast addresses’ states to drop on the device ports. If multicast devices exist on the VLAN and IGMP-snooping is not enabled, the bridge multicast forward-all command should be used to enable forwarding all multicast packets to the multicast switches. Example The following example enables bridge multicast filtering. Console(config)# bridge multicast filtering388 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY bridge multicast address Use the bridge multicast address Interface Configuration (VLAN) mode command to register a MAC-layer multicast address in the bridge table and statically add or remove ports to or from the group. Use the no form of this command to unregister the MAC address. Syntax bridge multicast address {mac-multicast-address} [[add | remove] {ethernet interface-list | port-channel port-channel-list}] no bridge multicast address {mac-multicast-address} Parameters • mac-multicast-address—Specifies the group MAC multicast address. • add—Adds ports to the group. • remove—Removes ports from the group. • ethernet interface-list—Specifies a list of Ethernet ports. Separate nonconsecutive Ethernet ports with a comma and no spaces. Use a hyphen to designate a range of ports. • port-channel port-channel-list—Specifies a list of port channels. Separate nonconsecutive port-channels with a comma and no spaces; use a hyphen to designate a range of port channels. Default Configuration No multicast addresses are defined. If ethernet interface-list or port-channel port-channel-list is specified without specifying add or remove, the default option is add. Command Mode Interface Configuration (VLAN) mode User Guidelines To register the group in the bridge database without adding or removing ports or port channels, specify the mac-multicast-address parameter only.Address Table Commands 389 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Static multicast addresses can be defined on static VLANs only. You can execute the command before the VLAN is created. Example The following example registers the MAC address to the bridge table: Console(config)# interface vlan 8 Console(config-if)# bridge multicast address 01:00:5e:02:02:03 The following example registers the MAC address and adds ports statically. Console(config)# interface vlan 8 Console(config-if)# bridge multicast address 01:00:5e:02:02:03 add gi1/0/1-2 bridge multicast forbidden address Use the bridge multicast forbidden address Interface Configuration (VLAN) mode command to forbid adding or removing a specific multicast address to or from specific ports. Use the no form of this command to restore the default configuration. Syntax bridge multicast forbidden address {mac-multicast-address} {add | remove} {ethernet interface-list | port-channel port-channel-list} no bridge multicast forbidden address {mac-multicast-address} Parameters • mac-multicast-address—Specifies the group MAC multicast address. • add—Forbids adding ports to the group. • remove—Forbids removing ports from the group. • ethernet interface-list—Specifies a list of Ethernet ports. Separate nonconsecutive Ethernet ports with a comma and no spaces. Use a hyphen to designate a range of ports.390 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • port-channel port-channel-list—Specifies a list of port channels. Separate nonconsecutive port-channels with a comma and no spaces. Use a hyphen to designate a range of port channels. Default Configuration No forbidden addresses are defined. Command Mode Interface Configuration (VLAN) mode User Guidelines Before defining forbidden ports, the multicast group should be registered. You can execute the command before the VLAN is created. Example The following example forbids MAC address 0100.5e02.0203 on port 2/9 within VLAN 8. Console(config)# interface vlan 8 Console(config-if)# bridge multicast address 0100.5e.02.0203 Console(config-if)# bridge multicast forbidden address 0100.5e02.0203 add gi1/0/9 bridge multicast unregistered Use the bridge multicast unregistered Interface Configuration (Ethernet, Port-Channel) mode command to configure the forwarding state of unregistered multicast addresses. Use the no form of this command to restore the default configuration. Syntax bridge multicast unregistered {forwarding | filtering} no bridge multicast unregistered Parameters • forwarding—Forwards unregistered multicast packets.Address Table Commands 391 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • filtering—Filters unregistered multicast packets. Default Configuration Unregistered multicast addresses are forwarded. Command Mode Interface Configuration (Ethernet, Port-Channel) mode User Guidelines Do not enable unregistered multicast filtering on ports that are connected to routers, because the 224.0.0.x address range should not be filtered. Note that routers do not necessarily send IGMP reports for the 224.0.0.x range. You can execute the command before the VLAN is created. Example The following example specifies that unregistered multicast packets are filtered on gigabitethernet port 1/0/1: Console(config)# interface gi1/0/1 Console(config-if)# bridge multicast unregistered filtering bridge multicast forward-all Use the bridge multicast forward-all Interface Configuration (VLAN) mode command to enable forwarding all multicast packets for a range of ports or port channels. Use the no form of this command to restore the default configuration. Syntax bridge multicast forward-all {add | remove} {ethernet interface-list | portchannel port-channel-list} no bridge multicast forward-all Parameters • add—Forces forwarding of all multicast packets. • remove—Does not force forwarding of all multicast packets.392 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • ethernet interface-list—Specifies a list of Ethernet ports. Separate nonconsecutive Ethernet ports with a comma and no spaces. Use a hyphen to designate a range of ports. • port-channel port-channel-list—Specifies a list of port channels. Separate nonconsecutive port-channels with a comma and no spaces. Use a hyphen to designate a range of port channels. Default Configuration Forwarding of all multicast packets is disabled. Command Mode Interface Configuration (VLAN) mode Example The following example enables all multicast packets on port gi1/0/8 to be forwarded. Console(config)# interface vlan 2 Console(config-if)# bridge multicast forward-all add gi1/0/8 bridge multicast forbidden forward-all Use the bridge multicast forbidden forward-all Interface Configuration (VLAN) mode command to forbid a port to dynamically join multicast groups. Use the no form of this command to restore the default configuration. Syntax bridge multicast forbidden forward-all {add | remove} {ethernet interfacelist | port-channel port-channel-list} no bridge multicast forbidden forward-all Parameters • add—Forbids forwarding of all multicast packets. • remove—Does not forbid forwarding of all multicast packets.Address Table Commands 393 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • ethernet interface-list—Specifies a list of Ethernet ports. Separate nonconsecutive Ethernet ports with a comma and no spaces. Use a hyphen to designate a range of ports. • port-channel port-channel-list—Specifies a list of port channels. Separate nonconsecutive port-channels with a comma and no spaces; use a hyphen to designate a range of port channels. Default Configuration Ports are not forbidden to dynamically join multicast groups. Command Mode Interface Configuration (VLAN) mode User Guidelines Use this command to forbid a port to dynamically join (by IGMP, for example) a multicast group. The port can still be a multicast router port. Example The following example forbids forwarding of all multicast packets to gi1/0/1 within VLAN 2. Console(config)# interface vlan 2 Console(config-if)# bridge multicast forbidden forward-all add ethernet gi1/0/1 mac address-table static Use the mac address-table static Global Configuration mode command to add MAC-layer station source address to the MAC address table. Use the no form of this command to delete the MAC address. Syntax mac address-table static mac-address vlan vlan-id interface interface-id [permanent | delete-on-reset | delete-on-timeout | secure ] no mac address-table static [mac-address] vlan vlan-id394 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters mac-address—AC address (Range: Valid MAC address) vlan-id—Specify the VLAN interface-id—Specify an interface ID. The interface ID can be one of the following types: Ethernet port or port-channel (Range: Valid Ethernet port, Valid Port-channel number) permanent—The address can only deleted by the no bridge address command. delete-on-reset—The address is deleted after reset. delete-on-timeout—The address is deleted after aged out. secure—The address is deleted after the port changes mode to unlock learning (no port security command). Available only when the port is in learning locked mode. Default Configuration No static addresses are defined. The default mode for an added address is permanent. Command Mode Global Configuration mode Example console(config)# mac address-table static 00:3f:bd:45:5a:b1 vlan 1 gi1/0/1 clear mac address-table Use the clear mac address-table Privileged EXEC command to remove learned or secure entries from the forwarding database. Syntax clear mac address-table dynamic [ interface interface-id ] clear mac address-table secure interface interface-idAddress Table Commands 395 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters interface interface-id—Delete all dynamic address on the specified interface.The interface ID can be one of the following types: Ethernet port or port-channel. Command Mode Privileged EXEC mode Example console# clear mac address-table dynamic mac address-table aging-time Use the mac address-table aging-time global configuration command to set the aging time of the address table. Use the no form of this command to restore the default. Syntax mac address-table aging-time seconds no mac address-table aging-time Parameters seconds—Time is number of seconds. (Range:10–300) Default Configuration 300 Command Mode Global Configuration mode Example console(config)# mac address-table aging-time 600396 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY port security Use the port security Interface Configuration (Ethernet, Port-channel) mode command to enable port security on an interface. Use the no form of this command to disable port security on an interface. Syntax port security [forward | discard | discard-shutdown] [trap seconds] no port security Parameters • forward—Forwards packets with unlearned source addresses, but does not learn the address. • discard—Discards packets with unlearned source addresses. • discard-shutdown—Discards packets with unlearned source addresses and shuts down the port. • trap seconds—Sends SNMP traps and specifies the minimum time interval in seconds between consecutive traps. (Range: 1–1000000) Default Configuration The feature is disabled The default mode is discard. Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example forwards all packets to port gi1/0/1 without learning addresses of packets from unknown sources and sends traps every 100 seconds if a packet with an unknown source address is received. console(config)# gi1/0/1 Console(config-if)# port security forward trap 100Address Table Commands 397 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY port security mode Use the port security mode Interface Configuration (Ethernet, port-channel) mode command configures the port security learning mode. Use the no form of this command to restore the default configuration. Syntax port security mode {lock | max-addresses } no port security mode Parameters • lock—Saves the current dynamic MAC addresses associated with the port and disables learning, relearning and aging. • max-addresses—Deletes the current dynamic MAC addresses associated with the port and learns up to the maximum number of addresses allowed on the port. Relearning and aging are enabled. Default Configuration The default port security mode is lock. Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example sets the port security mode to dynamic for gigabitethernet interface 1/0/7. Console(config)# interface gi1/0/7 Console(config-if)# port security mode dynamic port security max Use the port security mode Interface Configuration (Ethernet, Port-channel) mode command to configure the maximum number of addresses that can be learned on the port while the port is in port security max-addresses mode. Use the no form of this command to restore the default configuration.398 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax port security max {max-addr} no port security max Parameters max-addr—Specifies the maximum number of addresses that can be learned on the port. (Range: 0–128) Default Configuration This default maximum number of addresses is 1. Command Mode Interface Configuration (Ethernet, Port-channel) mode User Guidelines This command is relevant in port security max-addresses mode only. Example Console(config)# interface gi1/0/1 Console(config-if)# port security max 20 port security routed secure-address Use the port security routed secure-address Interface Configuration (Ethernet, Port-channel) mode command to add a MAC-layer secure address to a routed port. Use the no form of this command to delete a MAC address from a routed port. Syntax port security routed secure-address mac-address no port security routed secure-address [mac-address] Parameters mac-address—Specifies the MAC address.Address Table Commands 399 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration No addresses are defined. Command Mode Interface Configuration (Ethernet, port-channel) mode. It cannot be configured for a range of interfaces (range context). User Guidelines This command enables adding secure MAC addresses to a routed port in port security mode. The command is available when the port is a routed port and in port security mode. The address is deleted if the port exits the security mode or is not a routed port. This command is required because the bridge address command cannot be executed on internal VLANs. Example The following example adds the MAC-layer address 66:66:66:66:66:66 to gigabitethernet port 1/0/1. Console(config)# interface gi1/0/1 Console(config-if)# port security routed secure-address 66:66:66:66:66:66 show mac address-table Use the show mac address-table EXEC command to view entries in the MAC address table. Syntax show mac address-table [dynamic | static| secure] [vlan vlan] [interface interface-id] [address mac-address] Parameters • dynamic—Displays only dynamic MAC address table entries. • static—Displays only static MAC address table entries. • secure—Displays only secure MAC address table entries.400 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • vlan—Specifies VLAN, such as VLAN 1. • interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or port-channel. • mac-address—MAC address. Default Command Mode EXEC mode User Guidelines Internal usage VLANs (VLANs that are automatically allocated on routed ports) are presented in the VLAN column by a port number and not by a VLAN ID. Example Console# show mac address-table Aging time is 300 sec VLAN MAC Address Port Type -------- --------------------- ---------- ---------- 1 00:00:26:08:13:23 0 self 1 00:3f:bd:45:5a:b1 gi1/0/1 static 1 00:a1:b0:69:63:f3 gi1/0/24 dynamic 2 00:a1:b0:69:63:f3 gi1/0/24 dynamic Console# show mac address-table 00:3f:bd:45:5a:b1 Aging time is 300 sec VLAN MAC Address Port Type -------- --------------------- ---------- ---------- 1 00:3f:bd:45:5a:b1 static gi1/0/9Address Table Commands 401 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show mac address-table count Use the show mac address-table count EXEC mode command to display the number of addresses present in the Forwarding Database. Syntax show mac address-table count [vlan vlan | interface interface-id] Parameters • vlan—Specifies VLAN. • interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or port-channel. Command Mode EXEC mode Example Console# show mac address-table count Capacity: 8192 Free: 8083 Used: 109 Static addresses: 2 Secure addresses: 1 Dynamic addresses: 97 Internal addresses: 9 show bridge multicast address-table Use the show bridge multicast address-table EXEC mode command to display multicast MAC address or IP address table information.402 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show bridge multicast address-table [vlan vlan-id] [address {mac-multicastaddress | ipv4-multicast-address | ipv6-multicast-address}] [format {ip | mac}] Parameters • vlan vlan-id—Specifies the VLAN ID. • address {mac-multicast-address | ipv4-multicast-address | ipv6- multicast-address}—Specifies the multicast address. The possible values are: • mac-multicast-address—Specifies the MAC multicast address. • ipv4-multicast-address—Specifies the IPv4 multicast address. • ipv6-multicast-address—Specifies the IPv6 multicast address. • format {ip | mac}—Specifies the multicast address format. The possible values are: • ip—Specifies that the multicast address is an IP address. • mac—Specifies that the multicast address is a MAC address. Default Configuration If the format is not specified, it defaults to mac. Command Mode EXEC mode User Guidelines A MAC address can be displayed in IP format only if it is within the range 0100.5e00.0000 through 0100.5e7f.ffff. Multicast Router ports (defined statically or discovered dynamically) are members in all MC groups. Ports that were defined via bridge multicast forbidden forward-all command are displayed in all forbidden MC entries. Example The following example displays bridge multicast address information. Console# show bridge multicast address-tableAddress Table Commands 403 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Multicast address table for VLANs in MAC-GROUP bridging mode: Vlan MAC Address Type Ports ---- ----------------- -------------- ----- 8 01:00:5e:02:02:03 Static 1-2 Forbidden ports for multicast addresses: Vlan MAC Address Ports ---- ----------------- ----- 8 01:00:5e:02:02:03 gi1/0/9 Multicast address table for VLANs in IPv4-GROUP bridging mode: Vlan MAC Address Type Ports ---- ----------------- -------------- ----- 1 224.0.0.251 Dynamic gi1/0/12 Forbidden ports for multicast addresses: Vlan MAC Address Ports ---- ----------------- ----- 1 232.5.6.5 1 233.22.2.6 Multicast address table for VLANs in IPv4-SRC-GROUP bridging mode: Vlan Group Address Source address Type Ports ---- --------------- --------------- -------- ----- 1 224.2.2.251 11.2.2.3 Dynamic gi1/0/11 Forbidden ports for multicast addresses:404 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Vlan Group Address Source Address Ports ---- --------------- --------------- ------- 8 239.2.2.2 * gi1/0/9 8 239.2.2.2 1.1.1.11 gi1/0/9 Multicast address table for VLANs in IPv6-GROUP bridging mode: VLAN IP/MAC Address Type Ports ---- ----------------- --------- --------------------- 8 ff02::4:4:4 Static gi1/0/1-2,gi1/0/7,Po1 Forbidden ports for multicast addresses: VLAN IP/MAC Address Ports ---- ----------------- ----------- 8 ff02::4:4:4 gi1/0/9 Multicast address table for VLANs in IPv6-SRC-GROUP bridging mode: Vlan Group Address Source address Type Ports ---- --------------- --------------- -------- ------------------ 8 ff02::4:4:4 * Static gi1/0/1-2,gi1/0/7,Po1 8 ff02::4:4:4 fe80::200:7ff: Static fe00:200 Forbidden ports for multicast addresses: Vlan Group Address Source address Ports ---- --------------- --------------- ---------- 8 ff02::4:4:4 * gi1/0/9 8 ff02::4:4:4 fe80::200:7ff:f gi1/0/9 e00:200Address Table Commands 405 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show bridge multicast address-table static Use the show bridge multicast address-table static EXEC mode command to display the statically configured multicast addresses. Syntax show bridge multicast address-table static [vlan vlan-id] [address macmulticast-address | ipv4-multicast-address | ipv6-multicast-address] [source ipv4-source-address | ipv6-source-address] [all | mac | ip] Parameters • vlan vlan-id—Specifies the VLAN ID. • address {mac-multicast-address | ipv4-multicast-address | ipv6- multicast-address}—Specifies the multicast address. The possible values are: • mac-multicast-address—Specifies the MAC multicast address. • ipv4-multicast-address—Specifies the IPv4 multicast address. • ipv6-multicast-address—Specifies the IPv6 multicast address. • source {ipv4-source-address | ipv6-source-address}—Specifies the source address. The possible values are: • ipv4-address—Specifies the source IPv4 address. • ipv6-address—Specifies the source IPv6 address. Default Configuration When all/mac/ip is not specified, all entries (mac and ip) will be displayed. Command Mode EXEC mode User Guidelines A MAC address can be displayed in IP format only if it is within the range 0100.5e00.0000–- 0100.5e7f.ffff.406 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the statically configured multicast addresses. Console# show bridge multicast address-table static MAC-GROUP table Vlan ---- 1 MAC Address -------------- 0100.9923.8787 Ports -------- gi1/0/1, gi1/0/2 Forbidden ports for multicast addresses: Vlan ---- MAC Address -------------- Ports -------- IPv4-GROUP Table Vlan ---- 1 19 19 IP Address ---------- 231.2.2.3 231.2.2.8 231.2.2.8 Ports -------- gi1/0/1, gi1/0/2 gi1/0/1-8 gi1/0/9-11 Forbidden ports for multicast addresses: Vlan ---- 1 19 IP Address ---------- 231.2.2.3 231.2.2.8 Ports -------- gi1/0/8 gi1/0/8 IPv4-SRC-GROUP Table:Address Table Commands 407 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Vlan ---- Group Address --------------- Source address --------------- Ports ------ Forbidden ports for multicast addresses: Vlan ---- Group Address --------------- Source address --------------- Ports ------ IPv6-GROUP Table Vlan ---- 191 IP Address ----------------- FF12::8 Ports --------- gi1/0/1-8 Forbidden ports for multicast addresses: Vlan ---- 11 191 IP Address ----------------- FF12::3 FF12::8 Ports --------- gi1/0/8 gi1/0/8 IPv6-SRC-GROUP Table: Vlan ---- 192 Group Address --------------- FF12::8 Source address --------------- FE80::201:C9A9:FE40:8988 Ports ------ gi1/0/1- 8408 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show bridge multicast filtering Use the show bridge multicast filtering EXEC mode command to display the multicast filtering configuration. Syntax show bridge multicast filtering vlan-id Parameters vlan-id—Specifies the VLAN ID. (Range: Valid VLAN) Command Mode EXEC mode Forbidden ports for multicast addresses: Vlan ---- 192 Group Address --------------- FF12::3 Source address --------------- FE80::201:C9A9:FE40 :8988 Ports ------ gi1/0/8Address Table Commands 409 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the multicast configuration for VLAN 1. show bridge multicast unregistered Use the show bridge multicast unregistered EXEC mode command to display the unregistered multicast filtering configuration. Syntax show bridge multicast unregistered [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode EXEC mode Console# show bridge multicast filtering 1 Filtering: Enabled VLAN: 1 Port ----- gi1/0/1 gi1/0/2 gi1/0/3 Forward-All Static --------- Forbidden Forward - Status ------ Filter Forward(s) Forward(d)410 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays the unregistered multicast configuration. show ports security Use the show ports security Privileged EXEC mode command to display the port-lock status. Syntax show ports security [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode Privileged EXEC mode Example The following example displays the port-lock status of all ports. console# show ports security Port Status Learning Action Max Trap Frequency ------- -------- --------- ------ --- ------- -------- gi1/0/1 Enabled Max- Discard 3 Enabled 100 Addresses gi1/0/2 Disabled Max- - 28 - - Console# show bridge multicast unregistered Port ------- gi1/0/1 gi1/0/2 gi1/0/3 Unregistered ------------- Forward Filter FilterAddress Table Commands 411 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Addresses gi1/0/3 Enabled Lock Discard, 8 Disabled - Shutdown The following table describes the fields shown above. show ports security addresses Use the show ports security addresses Privileged EXEC mode command to display the current dynamic addresses in locked ports. Syntax show ports security addresses [interface-id Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode Privileged EXEC mode Field Description Port The port number. Status The port security status. The possible values are: Enabled or Disabled. Mode The port security mode. Action The action taken on violation. Maximum The maximum number of addresses that can be associated on this port in the Max-Addresses mode. Trap The status of SNMP traps. The possible values are: Enable or Disable. Frequency The minimum time interval between consecutive traps.412 Address Table Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Address_Table.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays dynamic addresses in all currently locked ports. Console# show ports security addresses Port ---- gi1/0/1 gi1/0/2 gi1/0/3 Status -------- Enabled Disabled Enabled Learning ------------- Max-addresses Max-addresses Lock Current ------- 2 - NA Maximum ------- 3 128 NAPort Monitor Commands 413 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Port_Monitor.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 27 Port Monitor Commands port monitor Use the port monitor Interface Configuration (Ethernet) mode command to start a port monitoring session. Use the no form of this command to stop a port monitoring session. Syntax port monitor src-interface-id [rx | tx] no port monitor src-interface-id Parameters • rx—Monitors received packets only. If no option is specified, it monitors both rx and tx. • tx—Monitors transmitted packets only. If no option is specified, it monitors both rx and tx. • src-interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Default Configuration Monitors both received and transmitted packets. Command Mode Interface Configuration (Ethernet) mode. It cannot be configured for a range of interfaces (range context).414 Port Monitor Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Port_Monitor.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines This command enables port copy between Source Port (src-interface) to a Destination Port (The port in context). The analyzer port for port ingress traffic mirroring should be the same port for all mirrored ports. The analyzer port for port egress traffic mirroring should be the same port for all mirrored ports. Following are restrictions apply for ports that are configured to be source ports: • The port cannot be a destination port. The following restrictions apply to ports that are configured to be monitor ports: • The port can’t be source port. • The port isn’t member in port-channel. • IP interface is not configured on the port. • GVRP is not enabled on the port. • The port is not a member in any VLAN, except for the default VLAN (will be automatically removed from the default VLAN). • L2 protocols are not active on the copy dest. Port: LLDP, LBD, STP, LACP. The following restrictions apply to ports that are configured to be monitor ports: • The port cannot be source port. • The port is not a member in port-channel. Notes: • In this mode some traffic duplication on the analyzer port may be observed. For example: • Port 2 is being egress monitored by port 4. • Port 2 & 4 are members in VLAN 3. • Unknown Unicast packet sent to VLAN 3 will egress from port 4 twice, one instance as normal forward and another instance as mirrored from port 2.Port Monitor Commands 415 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Port_Monitor.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • Moreover, if port 2 is an untagged member in VLAN 3 and port 4 is a tagged member then both instances will look different (one tagged and the other is not). • When the port is configured to 802.1X auto mode it will forward any mirrored traffic regardless of the .1X state. However, it will operate as a normal network port (forward traffic) only after authorization is done. • Mirrored traffic is exposed to STP state, i.e. if the port is in STP blocking, it will not egress any mirrored traffic. Example The following example copies traffic for both directions (Tx and Rx) from the source port gi1/0/8 to destination port gi1/0/1. Console(config)# interface gi1/0/1 Console(config-if)# port monitor gi1/0/8 show ports monitor Use the show ports monitor EXEC mode command to display the port monitoring status. Syntax show ports monitor Command Mode EXEC mode Example The following example displays the port monitoring status. Console# show ports monitor Source port Destination Port Type Status ----------- ---------------- -------- -------- gi1/0/8 gi1/0/1 RX,TX Active gi1/0/2 gi1/0/1 RX,TX Active gi1/0/18 gi1/0/1 RX Active416 Port Monitor Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Port_Monitor.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYsFlow Commands 417 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_sFlow.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 28 sFlow Commands sflow receiver Use the sflow receiver Global Configuration mode command to define sFlow collector. Use the no form of this command to remove the definition of the collector. Syntax sflow receiver index {ipv4-address | ipv6-address | hostname} [port port] [max-datagram-size bytes] no sflow receiver index Parameters • index—The index of the receiver. (Range: 1–8) • ipv4-address—Pv4 address of the host to be used as an sFlow Collector. • ipv6-address—IPv6 address of the host to be used as an sFlow Collector. When the IPv6 address is a Link Local address (IPv6Z address), the outgoing interface name must be specified. Refer to the User Guidelines for the interface name syntax. • hostname—Hostname of the host to be used as an sFlow Collector. Only translation to IPv4 addresses is supported. • port—Port number for syslog messages. If unspecified, the port number defaults to 6343. The range is 1-65535. • bytes—Specifies the maximum number of bytes that can be sent in a single sample datagram. If unspecified, it defaults to 1400. Default No receiver is defined.418 sFlow Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_sFlow.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode User Guidelines If the IP address of the sFlow receiver is set to 0.0.0.0, no sFlow datagrams are sent. sflow flow-sampling Use the sflow flow-sampling Interface Configuration mode command to enable sFlow Flow sampling and configure the average sampling rate of a specific port. Use the no form of this command to disable Flow sampling. Syntax sflow flow-sampling rate receiver-index [max-header-size bytes] no sflow flow-sampling Parameters  rate—Specifies the average sampling rate (Range: 1, 1024–1073741823.)  receiver-index—Index of the receiver/collector (Range: 1–8.)  bytes—Specifies the maximum number of bytes that would be copied from the sampled packet. If unspecified, defaults to 128. (Range: 20–256.) Default Disabled Command Mode Interface Configuration (Ethernet) mode User Guidelines A new sampling rate configuration is not immediately loaded to the hardware. It will be loaded to the hardware only after the next packet is sampled (based on the current sampling rate).sFlow Commands 419 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_sFlow.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY sflow counters-sampling Use the sflow counters-sampling Interface Configuration mode command to enable sFlow Counters sampling and to configure the maximum interval of a specific port. Use the no form of this command to disable sFlow Counters sampling. Syntax sflow counters-sampling interval receiver-index no sflow counters-sampling Parameters  interval—Specifies the maximum number of seconds between successive samples of the interface counters. (Range: 1, 15–86400.)  receiver-index—Index of the receiver/collector. (Range: 1–8.) Default Disabled Command Mode Interface Configuration (Ethernet) mode clear sflow statistics Use the clear sFlow statistics EXEC mode command to clear sFlow statistics. Syntax clear sflow statistics [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode EXEC mode420 sFlow Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_sFlow.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines If no interface is specified by the user, the command clears all the sFlow statistics counters (including datagrams sent). If an interface is specified by the user, the command clears only the counter of the specific interface. show sflow configuration Use the show sflow configuration EXEC mode command to display the sFlow configuration for ports that are enabled for Flow sampling or Counters sampling. Syntax show sflow configuration [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode EXEC mode Example Console # show sflow configuration Receivers Index IP Address Port Max Datagram Size ----- -------------------- -------- ---------------- 1 0.0.0.0 6343 1400 2 172.16.1.2 6343 1400 3 0.0.0.0 6343 1400 4 0.0.0.0 6343 1400 5 0.0.0.0 6343 1400 6 0.0.0.0 6343 1400 7 0.0.0.0 6343 1400 8 0.0.0.0 6343 1400 InterfacessFlow Commands 421 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_sFlow.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Inter- Flow Counters Max Header Flow Counters Collector face Sampling Sampling Size Collector Index Index ----- ----------- --------- --------- ---------- ----- ------------ gi1/0/1 1/2048 60 sec 128 1 1 gi1/0/2 1/4096 Disabled 128 0 2 show sflow statistics Use the show sflow statistics EXEC mode command to display the sFlow statistics for ports that are enabled for Flow sampling or Counters sampling. Syntax show sflow statistics [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode EXEC mode Example Console # show sflow statistics Total sFlow datagrams sent to collectors: 100 Interface Packets sampled datagrams sent to collector ---------- ----------- -------------- 1/1 30 50 1/2 10 10422 sFlow Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\750_sFlow.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY 1/1 0 10 1/2 0 0LLDP Commands 423 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 29 LLDP Commands lldp run Use the lldp run Global Configuration mode command to enable Link Layer Discovery Protocol (LLDP). To disable LLDP, use the no form of this command. Syntax lldp run no lldp run Parameters This command has no arguments or keywords. Default Enabled Command Mode Global Configuration mode Example console(config)# lldp run lldp transmit Use the lldp transmit Interface Configuration mode command to enable transmitting Link Layer Discovery Protocol (LLDP) on an interface. Use the no form of this command to stop transmitting LLDP on an interface.424 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax lldp transmit no lldp transmit Parameters This command has no arguments or keywords. Default Enabled Command Mode Interface Configuration (Ethernet) mode User Guidelines LLDP manages LAG ports individually. LLDP sends separate advertisements on each port in a LAG. LLDP operation on a port is not dependent on the STP state of a port. I.e. LLDP frames are sent on blocked ports. If a port is controlled by 802.1X, LLDP would operate only if the port is authorized. Example console(config)# interface gi1/0/1 console(config-if)# lldp transmit lldp receive Use the lldp receive Interface Configuration mode command to enable receiving Link Layer Discovery Protocol (LLDP) on an interface. Use the no form of this command to stop receiving LLDP on an interface. Syntax lldp receive no lldp receiveLLDP Commands 425 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters This command has no arguments or keywords. Default Enabled Command Mode Interface Configuration (Ethernet) mode User Guidelines LLDP manages LAG ports individually. LLDP data received through LAG ports is stored individually per port. LLDP operation on a port is not dependent on the STP state of a port. I.e. LLDP frames are received on blocked ports. If a port is controlled by 802.1X, LLDP would operate only if the port is authorized. Example console(config)# interface gi1/0/1 console(config-if)# lldp receive lldp timer Use the lldp timer Global Configuration mode command to specify how often the software sends Link Layer Discovery Protocol (LLDP) updates. Use the no form of this command to restore the default configuration. Syntax lldp timer seconds no lldp timer Parameters seconds—Specifies, in seconds, how often the software sends LLDP updates. (Range: 5-32768 seconds)426 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The default update interval is 30 seconds. Command Mode Global Configuration mode Example The following example sets the interval for sending LLDP updates to 60 seconds. Console(config)# lldp timer 60 lldp hold-multiplier Use the lldp hold-multiplier Global Configuration mode command to set the time interval during which the receiving device holds a Link Layer Discovery Protocol (LLDP) packet before discarding it. Use the no form of this command to restore the default configuration. Syntax lldp hold-multiplier number no lldp hold-multiplier Parameters number—Specifies the LLDP packet hold time interval as a multiple of the LLDP timer value. (Range: 2use the no form of this command10) Default Configuration The default LLDP hold multiplier is 4. Command Mode Global Configuration mode User Guidelines The actual Time-To-Live (TTL) value of LLDP frames is expressed by the following formula:LLDP Commands 427 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY TTL = min(65535, LLDP-Timer * LLDP-HoldMultiplier) For example, if the value of the LLDP timer is 30 seconds, and the value of the LLDP hold multiplier is 4, then the value 120 is encoded in the TTL field of the LLDP header. Example The following example sets the LLDP packet hold time interval to 90 seconds. Console(config)# lldp timer 30 Console(config)# lldp hold-multiplier 3 lldp reinit Use the lldp reinit Global Configuration mode command to specify the minimum time an LLDP port waits before reinitializing LLDP transmission. Use the no form of this command to revert to the default setting. Syntax lldp reinit seconds no lldp reinit Parameters seconds—Specifies the minimum time in seconds an LLDP port waits before reinitializing LLDP transmission.(Range: 1–10) Default 2 seconds Command Mode Global Configuration mode Example console(config)# lldp reinit 4428 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY lldp tx-delay Use the lldp tx-delay Global Configuration mode command to set the delay between successive LLDP frame transmissions initiated by value/status changes in the LLDP local systems MIB. Use the no form of this command to restore the default configuration. Syntax lldp tx-delay seconds no lldp tx-delay Parameters seconds—Specifies the delay in seconds between successive LLDP frame transmissions initiated by value/status changes in the LLDP local systems MIB. (Range: 1-8192 seconds) Default Configuration The default LLDP frame transmission delay is 2 seconds. Command Mode Global Configuration mode User Guidelines It is recommended that the tx-delay be less than 0.25 of the LLDP timer interval. Example The following example sets the LLDP transmission delay to 10 seconds. Console(config)# lldp tx-delay 10 lldp optional-tlv Use the lldp optional-tlv Interface Configuration (Ethernet) mode command to specify which optional TLVs from the basic set are transmitted. Use the no form of this command to restore the default configuration.LLDP Commands 429 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax lldp optional-tlv tlv [tlv2 … tlv5] no lldp optional-tlv Parameters tlv—Specifies TLV that should be included. Available optional TLVs are: port-desc, sys-name, sys-desc, sys-cap, 802.3-mac-phy, 802.3-lag, 802.3-maxframe-size. Default Configuration No optional TLV is transmitted. Command Mode Interface Configuration (Ethernet) mode Example The following example specifies that the port description TLV is transmitted on gigabitethernet port 1/0/2. Console(config)# interface gi1/0/2 Console(config-if)# lldp optional-tlv port-desc lldp management-address Use the lldp management-address Interface Configuration (Ethernet) mode command to specify the management address advertised from an interface. Use the no form of this command to stop advertising management address information. Syntax lldp management-address {ip-address | none | automatic [interface-id] } no lldp management-address Parameters • ip-address—Specifies the static management address to advertise. • none—Specifies that no address is advertised.430 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • automatic—Specifies that the software would automatically choose a management address to advertise from all the IP addresses of the product. In case of multiple IP addresses the software chooses the lowest IP address among the dynamic IP addresses. If there are no dynamic addresses, the software chooses the lowest IP address among the static IP addresses. • automatic interface-id—Specifies that the software automatically chooses a management address to advertise from the IP ddresses that are configured (associated) for the interface ID. In case of multiple IP addresses, the software chooses the lowest IP address among the dynamic IP addresses of the interface. If there are no dynamic addresses, the software chooses the lowest IP address among the static IP addresses of the interface. The interface ID can be one of the following types: Ethernet port, Port-channel or VLAN. Note that if the port or port- channel are members in a VLAN that has an IP address, that address is not included because the address is associated with the VLAN. Default Configuration No IP address is advertised. The default advertisement is automatic. Command Mode Interface Configuration (Ethernet) mode User Guidelines Each port can advertise one IP address. Example The following example sets the LLDP management address advertisement mode to automatic on gigabitethernet port 1/0/2. Console(config)# interface gi1/0/2 Console(config)# lldp management-address automatic lldp notifications Use the lldp notifications Interface Configuration (Ethernet) mode command to enable or disable sending Link Layer Discovery Protocol (LLDP) LLDP Commands 431 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY notifications on an interface. Use the no form of this command to restore the default configuration. Syntax lldp notifications {enable | disable} no lldp notifications Parameters • enable—Enables sending LLDP notifications. • disable—Disables sending LLDP notifications. Default Configuration Sending LLDP notifications is disabled. Command Mode Interface Configuration (Ethernet) mode Example The following example enables sending LLDP notifications on gigabitethernet port 1/0/5. Console(config)# interface gi1/0/5 Console(config)# lldp notifications 10 lldp notifications interval Use the lldp notifications interval Global Configuration mode command to configure the maximum transmission rate of LLDP notifications. Use the no form of this command to return to the default. Syntax lldp notifications interval seconds no lldp notifications interval432 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters seconds—The device should not send more than one notification in the indicated period. (Range: 5–3600) Default 5 seconds Command Mode Global Configuration mode Example console(config)# lldp notification interval 10 lldp optional-tlv 802.1 Use the lldp optional-tlv Interface Configuration mode command to specify which optional TLVs from the basic set to transmit. Use the no form of this command revert to the default setting. Syntax lldp optional-tlv 802.1 pvid no lldp optional-tlv 802.1 pvid lldp optional-tlv 802.1 ppvid add ppvid lldp optional-tlv 802.1 ppvid remove ppvid lldp optional-tlv 802.1 vlan-name add vlan-id lldp optional-tlv 802.1 vlan-name remove vlan-id lldp optional-tlv 802.1 protocol add {stp | rstp | mstp | pause | 802.1x | lacp | gvrp} lldp optional-tlv 802.1 protocol remove {stp | rstp | mstp | pause | 802.1x | lacp | gvrp} Parameters • pvid—Advertises the PVID of the port.LLDP Commands 433 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • ppvid—Adds/removes PPVID for advertising. PPVID 0 can be used to advertise the PPVIDs capabilities of the interface.(Range: 0–4094) • vlan—Adds/removse VLAN ID for advertising. (Range: 1–4094) Default No optional TLV is transmitted. Command Mode Interface Configuration (Ethernet) mode lldp med enable Use the lldp med enable Interface Configuration (Ethernet) mode command to enable Link Layer Discovery Protocol (LLDP) Media Endpoint Discovery (MED) on an interface. Use the no form of this command to disable LLDP MED on an interface. Syntax lldp med enable [tlv … tlv4] no lldp med enable Parameters tlv—Specifies the TLV that should be included. Available TLVs are: networkpolicy, location, and poe-pse, inventory. The capabilities TLV is always included if LLDP-MED is enabled. Default Configuration LLDP MED is disabled. Command Mode Interface Configuration (Ethernet) mode Example The following example enables LLDP MED with the location TLV on gigabitethernet port 1/0/3.434 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Console(config)# interface gi1/0/3 Console(config)# lldp med enable location lldp med notifications topology-change Use the lldp med notifications topology-change Interface Configuration (Ethernet) mode command to enable sending LLDP MED topology change notifications. Use the no form of this command to restore the default configuration. Syntax lldp med notifications topology-change {enable | disable} no lldp med notifications topology-change Parameters • enable—Enables sending LLDP MED topology change notifications. • disable—Disables sending LLDP MED topology change notifications. Default Configuration Disable is the default. Command Mode Interface Configuration (Ethernet) mode Example The following example enables sending LLDP MED topology change notifications on gigabitethernet port 1/0/2. Console(config)# interface gi1/0/2 Console(config)# lldp med notifications topology-change enableLLDP Commands 435 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY lldp med fast-start repeat-count Use the lldp med fast-start repeat-count Global Configuration mode command to configure the number of times the fast start LLDPDU is being sent during the activation of the fast start mechanism defined by LLDPMED. Use the no form of this command return to default. Syntax lldp med fast-start repeat-count number no lldp med fast-start repeat-count Parameters number—Specifies the number of times the fast start LLDPDU is being sent during the activation of the fast start mechanism. Default 3 Command Mode Global Configuration mode Example console(config)# lldp med fast-start repeat-count 4 lldp med network-policy (global) Use the lldp med network-policy Global Configuration mode command to define LLDP MED network policy. Use the no form of this command to remove LLDP MED network policy. Syntax lldp med network-policy number application [vlan id] [vlan-type {tagged | untagged}] [up priority] [dscp value] no lldp med network-policy number436 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • number—Network policy sequential number. • application—The name or the number of the primary function of the application defined for this network policy. Available application names are: voice, voice-signaling, guest-voice, guest-voice-signaling, softphonevoice, video-conferencing, streaming-video, video-signaling. • vlan id—VLAN identifier for the application. • vlan-type—Specifies if the application is using a Tagged or an Untagged VLAN. • up priority—User Priority (Layer 2 priority) to be used for the specified application. • dscp value—DSCP value to be used for the specified application. Default No Network policy is defined. Command Mode Global Configuration mode User Guidelines Use the lldp med network-policy Interface Configuration command to attach a network policy to a port. Up to 32 network policies can be defined. Example console(config)# lldp med network-policy 1 voice-signaling vlan 1 lldp med network-policy (interface) Use the lldp med network-policy Interface Configuration (Ethernet) mode command to attach or remove an LLDP MED network policy on an interface. Use the no form of this command to remove all the LLDP MED network policies from the interface.LLDP Commands 437 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax lldp med network-policy {add | remove} number no lldp med network-policy number Parameters • number—Specifies the network policy sequential number. • add—Attaches the specified network policy to the interface. • remove—Removes the specified network policy from the interface. Default Configuration No network policy is attached to the interface. Command Mode Interface Configuration (Ethernet) mode User Guidelines For each port, only one network policy per application (voice, voice-signaling, etc.) can be defined. Example The following example attaches LLDP MED network policy 1 to gigabitethernet port 1/0/1. Console(config)# interface gi1/0/1 Console(config-if)# lldp med network-policy add 1 clear lldp table Use the clear lldp table command in Privileged EXEC mode to restart the LLDP RX state machine and clear the neighbors table. Syntax clear lldp table [interface-id]438 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode Example console# clear lldp table gi1/0/1 lldp med location Use the lldp med location Interface Configuration (Ethernet) mode command to configure the location information for the Link Layer Discovery Protocol (LLDP) Media Endpoint Discovery (MED) for an interface. Use the no form of this command to delete location information for an interface. Syntax lldp med location {{coordinate data} | {civic-address data} | {ecs-elin data}} no lldp med location {coordinate | civic-address | ecs-elin} Parameters • coordinate—Specifies the location data as coordinates. • civic-address—Specifies the location data as a civic address. • ecs-elin—Specifies the location data as an Emergency Call Service Emergency Location Identification Number (ECS ELIN). • data—Specifies the location data in the format defined in ANSI/TIA 1057: dotted hexadecimal data: Each byte in a hexadecimal character string is two hexadecimal digits. Bytes are separated by a period or colon. (Length: coordinate: 16 bytes. Civic-address: 6-160 bytes. Ecs-elin: 10-25 bytes) Default Configuration The location is not configured.LLDP Commands 439 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Interface Configuration (Ethernet) mode Example The following example configures the LLDP MED location information on gigabitethernet port 1/0/2 as a civic address. console(config)# interface gi1/0/2 console(config-if)# lldp med location civic-address 616263646566 show lldp configuration Use the show lldp configuration Privileged EXEC mode command to display the Link Layer Discovery Protocol (LLDP) configuration for all interfaces or for a specific interface. Syntax show lldp configuration [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode Example The following example sets the LLDP re-initialization delay to 10 seconds. Switch# show lldp configuration State: Enabled Timer: 30 Seconds Hold multiplier: 4 Reinit delay: 2 Seconds Tx delay: 2 Seconds Notifications interval: 5 seconds440 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY LLDP packets handling: Filtering Port State Optional TLVs Address Notifications ---- ----- -------------- ------- ------------ gi1/0/1 RX,TX PD, SN, SD, SC 172.16.1.1 Disabled gi1/0/2 TX PD, SN 172.16.1.1 Disabled gi1/0/3 RX,TX PD, SN, SD, SC None Disabled gi1/0/5 RX,TX D, SN, SD, SC automatic Disabled gi1/0/6 RX,TX PD, SN, SD, SC auto vlan 1 Disabled gi1/0/7 RX,TX PD, SN, SD, SC auto g1 Disabled gi1/0/8 RX,TX PD, SN, SD, SC auto ch1 Disabled Switch# show lldp configuration gi1/0/1 State: Enabled Timer: 30 Seconds Hold multiplier: 4 Reinit delay: 2 Seconds Tx delay: 2 Seconds Notifications interval: 5 seconds LLDP packets handling: Filtering Port State Optional TLVs Address Notifications -------------- -------------- ------------------------ gi1/0/1 RX, TX PD, SN, SD, SC 72.16.1.1 Disabled 802.3 optional TLVs: 802.3-mac-phy, 802.3-lag, 802.3-max-frame-size 802.1 optional TLVs PVID: Enabled PPVIDs: 0, 1, 92 VLANs: 1, 92 Protocols: 802.1xLLDP Commands 441 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY The following table describes the significant fields shown in the display: show lldp med configuration Use the show lldp med configuration Privileged EXEC mode command to display the Link Layer Discovery Protocol (LLDP) Media Endpoint Discovery (MED) configuration for all interfaces or for a specific interface. Syntax show lldp med configuration [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Field Description Timer The time interval between LLDP updates. Hold multiplier The amount of time (as a multiple of the timer interval) that the receiving device holds a Link Layer Discovery Protocol (LLDP) packet before discarding it. Reinit timer The minimum time interval an LLDP port waits before reinitializing an LLDP transmission. Tx delay The delay between successive LLDP frame transmissions initiated by value/status changes in the LLDP local systems MIB. Port The port number. State The port’s LLDP state. Optional TLVs Optional TLVs that are advertised. Possible values are: PD - Port description SN - System name SD - System description SC - System capabilities Address The management address that is advertised. Notifications Indicates whether LLDP notifications are enabled or disabled.442 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Privileged EXEC mode Example The following examples display the LLDP MED configuration for all interfaces and for gigabitethernet port 1/0/1. console# show lldp med configuration Fast Start Repeat Count: 4. Network policy 1 ------------------- Application type: voiceSignaling VLAN ID: 1 untagged Layer 2 priority: 0 DSCP: 0 Port Capabilities Network Location Notifications Inventory policy ------ ----------- ---------- ---------- ------------ -------- gi1/0/1 Yes Yes Yes Enabled Yes gi1/0/2 Yes Yes No Enabled No gi1/0/3 No No No Enabled No console# show lldp med configuration gi1/0/1 Port Capabilities Network policy Location Notifications Inventory ------------------- -------------- -------- ---------- -------- gi1/0/1 Yes Yes Yes Enabled Yes Network policies: Location: Civic-address: 61:62:63:64:65:66LLDP Commands 443 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show lldp local tlvs-overloading Use the show lldp local tlvs-overloading EXEC mode command to display the status of TLVs overloading of the Link Layer Discovery Protocol (LLDP). Syntax show lldp local tlvs-overloading [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode EXEC mode User Guidelines The command calculates the overloading status of the current LLDP configuration, and not for the last LLDP packet that was sent. Example Switch# show lldp local tlvs-overloading Ports with LLDP TLV overloading are: gi1/0/1, gi1/0/9 Switch# show lldp local tlvs-overloading No LLDP TLV overloading. Switch# show lldp local tlvs-overloading gi1/0/1 TLVs Group Bytes Status ------------ ------ -------------- Mandatory 31 Transmitted LLDP-MED Capabilities 9 Transmitted LLDP-MED Location 200 Transmitted 802.1 1360 Overloading Total: 1600 bytes Left: 100 bytes444 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show lldp local Use the show lldp local Privileged EXEC mode command to display the Link Layer Discovery Protocol (LLDP) information that is advertised from a specific port. Syntax show lldp local interface-id Parameters Interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode Example The following examples display LLDP information that is advertised from gigabitethernet ports 1/0/1 and 1/0/2. Switch# show lldp local gi1/0/1 Device ID: 0060.704C.73FF Port ID: gi1/0/1 Capabilities: Bridge System Name: ts-7800-1 System description: Port description: Management address: 172.16.1.8 802.3 MAC/PHY Configuration/Status Auto-negotiation support: Supported Auto-negotiation status: Enabled Auto-negotiation Advertised Capabilities: 100BASE-TX full duplex, 1000BASE-T full duplex Operational MAU type: 1000BaseTFD 802.3 Link Aggregation Aggregation capability: Capable of being aggregated Aggregation status: Not currently in aggregationLLDP Commands 445 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Aggregation port ID: 1 802.3 Maximum Frame Size: 1522 802.3 EEE Local Tx: 30 usec Local Rx: 25 usec Remote Tx Echo: 30 usec Remote Rx Echo: 25 usec 802.1 PVID: 1 802.1 PPVID: 2 supported, enabled 802.1 VLAN: 2 (VLAN2) 802.1 Protocol: 88 8E 01 LLDP-MED capabilities: Network Policy, Location Identification LLDP-MED Device type: Network Connectivity LLDP-MED Network policy Application type: Voice Flags: Tagged VLAN VLAN ID: 2 Layer 2 priority: 0 DSCP: 0 LLDP-MED Power over Ethernet Device Type: Power Sourcing Entity Power source: Primary Power Source Power priority: High Power value: 9.6 Watts LLDP-MED Location Coordinates: 54:53:c1:f7:51:57:50:ba:5b:97:27:80:00:00:67:01 LLDP-MED Inventory Hardware Revision: B1 Firmware Revision: A1446 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Software Revision: 3.8 Serial number: 7978399 Manufacturer name: Manufacturer Model name: Model 1 Asset ID: Asset 123 Switch# show lldp local gi1/0/2 LLDP is disabled. show lldp neighbors Use the show lldp neighbors Privileged EXEC mode command to display information about neighboring devices discovered using Link Layer Discovery Protocol (LLDP). The information can be displayed for all interfaces or for a specific interface. Syntax show lldp neighbors [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode Privileged EXEC mode User Guidelines There are no guidelines for this command. A TLV value that cannot be displayed as an ASCII string is displayed as an hexadecimal string. Example The following examples display information about neighboring devices discovered using LLDP. Location information, if it exists, is also displayed.LLDP Commands 447 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Switch# show lldp neighbors Port Device ID Port ID System Name Capabilities TTL ----- ------------------ -------- ---------- ----------- ---- gi1/0/1 00:00:00:11:11:11 gi1/0/1 ts-7800-2 B 90 gi1/0/1 00:00:00:11:11:11 D gi1/0/1 ts-7800-2 B 90 gi1/0/2 00:00:26:08:13:24 gi1/0/3 ts-7900-1 B, R 90 gi1/0/3 00:00:26:08:13:24 gi1/0/2 ts-7900-2 W 90 Switch# show lldp neighbors gi1/0/1 Device ID: 00:00:00:11:11:11 Port ID: gi1/0/ System Name: ts-7800-2 Capabilities: B System description: Port description: Management address: 172.16.1.1 Time To Live: 90 seconds 802.3 MAC/PHY Configuration/Status Auto-negotiation support: Supported. Auto-negotiation status: Enabled. Auto-negotiation Advertised Capabilities: 100BASE-TX full duplex, 1000BASE-T full duplex. Operational MAU type: 1000BaseTFD 802.3 Power via MDI MDI Power support Port Class: PD PSE MDI Power Support: Not Supported PSE MDI Power State: Not Enabled PSE power pair control ability: Not supported. PSE Power Pair: Signal PSE Power class: 1 802.3 Link Aggregation448 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Aggregation capability: Capable of being aggregated Aggregation status: Not currently in aggregation Aggregation port ID: 1 802.3 Maximum Frame Size: 1522 802.3 EEE Remote Tx: 25 usec Remote Rx: 30 usec Local Tx Echo: 30 usec Local Rx Echo: 25 usec 802.1 PVID: 1 802.1 PPVID: 2 supported, enabled 802.1 VLAN: 2(VLAN2) 802.1 Protocol: 88 8E 01 LLDP-MED capabilities: Network Policy. LLDP-MED Device type: Endpoint class 2. LLDP-MED Network policy Application type: Voice Flags: Unknown policy VLAN ID: 0 Layer 2 priority: 0 DSCP: 0 LLDP-MED Power over Ethernet Device Type: Power Device Power source: Primary power Power priority: High Power value: 9.6 Watts LLDP-MED Inventory Hardware revision: 2.1 Firmware revision: 2.3LLDP Commands 449 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Software revision: 2.7.1 Serial number: LM759846587 Manufacturer name: VP Model name: TR12 Asset ID: 9 LLDP-MED Location Coordinates: 54:53:c1:f7:51:57:50:ba:5b:97:27:80:00:00:67:01 The following table describes significant LLDP fields shown in the display: Field Description Port The port number. Device ID The neighbor device’s configured ID (name) or MAC address. Port ID The neighbor device’s port ID. System name The neighbor device’s administratively assigned name. Capabilities The capabilities discovered on the neighbor device. Possible values are: B - Bridge R - Router W - WLAN Access Point T - Telephone D - DOCSIS cable device H - Host r - Repeater O - Other System description The neighbor device’s system description. Port description The neighbor device’s port description. Management address The neighbor device’s management address. Auto-negotiation support The auto-negotiation support status on the port. (Supported or Not Supported) Auto-negotiation status The active status of auto-negotiation on the port. (Enabled or Disabled)450 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Auto-negotiation Advertised Capabilities The port speed/duplex/flow-control capabilities advertised by the auto-negotiation. Operational MAU type The port MAU type. LLDP MED Capabilities The sender's LLDP-MED capabilities. Device type The device type. Indicates whether the sender is a Network Connectivity Device or Endpoint Device, and if an Endpoint, to which Endpoint Class it belongs. LLDP MED - Network Policy Application type The primary function of the application defined for this network policy. Flags Flags. The possible values are: Unknown policy: Policy is required by the device, but is currently unknown. Tagged VLAN: The specified application type is using a Tagged VLAN. Untagged VLAN: The specified application type is using an Untagged VLAN. VLAN ID The VLAN identifier for the application. Layer 2 priority The Layer 2 priority used for the specified application. DSCP The DSCP value used for the specified application. LLDP MED - Power Over Ethernet Power type The device power type. The possible values are: Power Sourcing Entity (PSE) or Power Device (PD). Power Source The power source utilized by a PSE or PD device. A PSE device advertises its power capability. The possible values are: Primary power source and Backup power source. A PD device advertises its power source. The possible values are: Primary power, Local power, Primary and Local power. Power priority The PD device priority. A PSE device advertises the power priority configured for the port. A PD device advertises the power priority configured for the device. The possible values are: Critical, High and Low.LLDP Commands 451 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show lldp statistics Use the show lldp statistics EXEC mode command to display the Link Layer Discovery Protocol (LLDP) statistics. Syntax show lldp statistics [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID must be an Ethernet port. Command Mode EXEC mode Example Switch# show lldp statistics Contax(config-if)# do show lldp statistics Tables Last Change Time: 14-Oct-2010 32:08:18 Tables Inserts: 26 Tables Deletes: 2 Tables Dropped: 0 Tables Ageouts: 1 Power value The total power in watts required by a PD device from a PSE device, or the total power a PSE device is capable of sourcing over a maximum length cable based on its current configuration. LLDP MED - Location Coordinates, Civic address, ECS ELIN. The location information raw data.452 LLDP Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\LLDP.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY TX Frames RX Frames RX TLVs RX Ageouts Port Total Total Discarded Errors Discarded Unrecognized Total --------- --------- --------- --------- ------ --------- ------------ ------------------ ----------- gi1/0/1 730 850 0 0 0 0 0 gi1/0/2 0 0 0 0 0 0 0 gi1/0/3 730 0 0 0 0 0 0 gi1/0/4 0 0 0 0 0 0 0 gi1/0/5 0 0 0 0 0 0 0 gi1/0/6 8 7 0 0 0 0 1 gi1/0//7 0 0 0 0 0 0 0 gi1/0/8 0 0 0 0 0 0 0 gi1/0/9 730 0 0 0 0 0 0 gi1/0/10 0 0 0 0 0 0 0Spanning-Tree Commands 453 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 30 Spanning-Tree Commands spanning-tree Use the spanning-tree Global Configuration mode command to enable spanning-tree functionality. Use the no form of this command to disable the spanning-tree functionality. Syntax spanning-tree no spanning-tree Default Configuration Spanning-tree is enabled. Command Mode Global Configuration mode Example The following example enables spanning-tree functionality. Console(config)# spanning-tree spanning-tree mode Use the spanning-tree mode Global Configuration mode command to configure the spanning-tree protocol currently running. Use the no form of this command to restore the default configuration.454 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax spanning-tree mode {stp | rstp | mst} no spanning-tree mode Parameters • stp—Specifies that the Spanning Tree Protocol (STP) is enabled. • rstp—Specifies that the Rapid Spanning Tree Protocol (RSTP) is enabled. • mst—Specifies that the Multiple Spanning Tree Protocol (MSTP) is enabled. Default Configuration The default is RSTP. Command Mode Global Configuration mode User Guidelines In RSTP mode, the device uses STP when the neighbor device uses STP. In MSTP mode, the device uses RSTP when the neighbor device uses RSTP, and uses STP when the neighbor device uses STP. Example The following example configures the spanning-tree protocol as RSTP. console(config)# spanning-tree mode mstp spanning-tree forward-time Use the spanning-tree forward-time Global Configuration mode command to configure the spanning-tree bridge forward time, which is the amount of time a port remains in the listening and learning states before entering the forwarding state. Use the no form of this command to restore the default configuration.Spanning-Tree Commands 455 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax spanning-tree forward-time seconds no spanning-tree forward-time Parameters seconds—Specifies the spanning-tree forward time in seconds. (Range: 4–30) Default Configuration The default forwarding time for the IEEE Spanning Tree Protocol (STP) is 15 seconds. Command Mode Global Configuration mode User Guidelines When configuring the forwarding time, the following relationship should be maintained: 2*(Forward-Time - 1) >= Max-Age Example The following example configures the spanning tree bridge forwarding time to 25 seconds. Console(config)# spanning-tree forward-time 25 spanning-tree hello-time Use the spanning-tree hello-time Global Configuration mode command to configure the spanning tree bridge Hello time, which is how often the device broadcasts Hello messages to other devices. Use the no form of this command to restore the default configuration. Syntax spanning-tree hello-time seconds no spanning-tree hello-time456 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters seconds—Specifies the spanning-tree Hello time in seconds. (Range: 1–10) Default Configuration The default Hello time for IEEE Spanning Tree Protocol (STP) is 2 seconds. Command Mode Global Configuration mode User Guidelines When configuring the Hello time, the following relationship should be maintained: Max-Age >= 2*(Hello-Time + 1) Example The following example configures the spanning-tree bridge hello time to 5 seconds. Console(config)# spanning-tree hello-time 5 spanning-tree max-age Use the spanning-tree max-age Global Configuration mode command to configure the spanning-tree bridge maximum age. Use the no form of this command to restore the default configuration. Syntax spanning-tree max-age seconds no spanning-tree max-age Parameters seconds—Specifies the spanning-tree bridge maximum age in seconds. (Range: 6–40)Spanning-Tree Commands 457 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The default maximum age for IEEE Spanning Tree Protocol (STP) is 20 seconds. Command Mode Global Configuration mode User Guidelines When configuring the maximum age, the following relationships should be maintained: 2*(Forward-Time - 1) >= Max-Age Max-Age >= 2*(Hello-Time + 1) Example The following example configures the spanning-tree bridge maximum age to 10 seconds. Console(config)# spanning-tree max-age 10 spanning-tree priority Use the spanning-tree priority Global Configuration mode command to configure the device spanning-tree priority, which is used to determine which bridge is selected as the root bridge. Use the no form of this command to restore the default device spanning-tree priority. Syntax spanning-tree priority priority no spanning-tree priority Parameters priority—Specifies the bridge priority. (Range: 0–61440) Default Configuration The default bridge priority for IEEE Spanning Tree Protocol (STP) is 32768.458 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode User Guidelines The priority value must be a multiple of 4096. The switch with the lowest priority is the root of the spanning tree. Example The following example configures the spanning-tree priority to 12288. Console(config)# spanning-tree priority 12288 spanning-tree disable Use the spanning-tree disable Interface Configuration (Ethernet, portchannel) mode command to disable the spanning tree on a specific port. Use the no form of this command to enable the spanning tree on a port. Syntax spanning-tree disable no spanning-tree disable Default Configuration Spanning tree is enabled on all ports. Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example disables the spanning tree on gigabitethernet port 1/0/5 Console(config)# interface gi1/0/5 Console(config-if)# spanning-tree disableSpanning-Tree Commands 459 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY spanning-tree cost Use the spanning-tree cost Interface Configuration (Ethernet, port-channel) mode command to configure the spanning-tree path cost for a port. Use the no form of this command to restore the default configuration. Syntax spanning-tree cost cost no spanning-tree cost Parameters cost—Specifies the port path cost. (Range: 1–200000000) Default Configuration Default path cost is determined by port speed and path cost method (long or short) as shown below: Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example configures the spanning-tree cost on gigabitethernet port 1/0/15 to 35000. Console(config)# interface gi1/0/15 Console(config-if)# spanning-tree cost 35000 Interface Long Short Port-channel 20,000 4 TenGigabit Ethernet (10000 Mbps) 2000 2 Gigabit Ethernet (1000 Mbps) 20,000 4 Fast Ethernet (100 Mbps) 200,000 19 Ethernet (10 Mbps) 2,000,000 100460 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY spanning-tree port-priority Use the spanning-tree port-priority Interface Configuration (Ethernet, portchannel) mode command to configure the port priority. Use the no form of this command to restore the default configuration. Syntax spanning-tree port-priority priority no spanning-tree port-priority Parameters priority—Specifies the port priority. (Range: 0–240) Default Configuration The default port priority for IEEE Spanning Tree Protocol (STP) is 128. Command Mode Interface Configuration (Ethernet, port-channel) mode User Guidelines The priority value must be a multiple of 16. Example The following example configures the spanning priority on gigabitethernet port 1/0/15 to 96 Console(config)# interface gi1/0/15 Console(config-if)# spanning-tree port-priority 96 spanning-tree portfast Use the spanning-tree portfast Interface Configuration (Ethernet, portchannel) mode command to enable the PortFast mode. In PortFast mode, the interface is immediately put into the forwarding state upon linkup, without waiting for the standard forward time delay. Use the no form of this command to disable the PortFast mode.Spanning-Tree Commands 461 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax spanning-tree portfast [auto] no spanning-tree portfast Parameters auto—Specifies that the software waits for 3 seconds (with no BPDUs received on the interface) before putting the interface into the PortFast mode. Default Configuration PortFast mode is disabled. Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example enables the PortFast mode on gigabitethernet port 1/0/15. Console(config)# interface gi1/0/15 Console(config-if)# spanning-tree portfast spanning-tree link-type Use the spanning-tree link-type Interface Configuration (Ethernet, portchannel) mode command to override the default link-type setting determined by the port duplex mode, and enable Rapid Spanning Tree Protocol (RSTP) transitions to the forwarding state. Use the no form of this command to restore the default configuration. Syntax spanning-tree link-type {point-to-point | shared} no spanning-tree spanning-tree link-type Parameters • point-to-point—Specifies that the port link type is point-to-point.462 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • shared—Specifies that the port link type is shared. Default Configuration The device derives the port link type from the duplex mode. A full-duplex port is considered a point-to-point link and a half-duplex port is considered a shared link. Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example enables shared spanning-tree on gigabitethernet port 1/0/15. Console(config)# interface gi1/0/15 Console(config-if)# spanning-tree link-type shared spanning-tree pathcost method Use the spanning-tree pathcost method Global Configuration mode command to set the default path cost method. Use the no form of this command to return to the default configuration. Syntax spanning-tree pathcost method {long | short} no spanning-tree pathcost method Parameters • long—Specifies that the default port path costs are within the range: 1–200,000,000. • short—Specifies that the default port path costs are within the range: 1–65,535. Default Configuration Short path cost method.Spanning-Tree Commands 463 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Global Configuration mode User Guidelines This command applies to all the spanning tree instances on the switch. • If the short method is chosen, the switch use for the default cost values in the range 1 through 65,535. • If the long method is chosen, the switch use for the default cost values in the range 1 through 200,000,000. Example The following example sets the default path cost method to Long. Console(config)# spanning-tree pathcost method long spanning-tree bpdu (Global) Use the spanning-tree bpdu Global Configuration mode command to define BPDU handling when the spanning tree is disabled globally or on a single interface. Use the no form of this command to restore the default configuration. Syntax spanning-tree bpdu {filtering | flooding} no spanning-tree bpdu Parameters • filtering—Specifies that BPDU packets are filtered when the spanning tree is disabled on an interface. • flooding—Specifies that untagged BPDU packets are flooded unconditionally (without applying VLAN rules) to all ports with the spanning tree disabled and BPDU handling mode of flooding. Tagged BPDU packets are filtered.464 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The default setting is flooding. Command Mode Global Configuration mode User Guidelines The filtering and flooding modes are relevant when the spanning tree is disabled globally or on a single interface. Example The following example defines the BPDU packet handling mode as flooding when the spanning tree is disabled on an interface. Console(config)# spanning-tree bpdu flooding spanning-tree bpdu (Interface) Use the spanning-tree bpdu Interface Configuration (Ethernet, Portchannel) mode command to define BPDU handling when the spanning tree is disabled on a single interface. Use the no form of this command to restore the default configuration. Syntax spanning-tree bpdu {filtering | flooding} no spanning-tree bpdu Parameters • filtering—Specifies that BPDU packets are filtered when the spanning tree is disabled on an interface. • flooding—Specifies that untagged BPDU packets are flooded unconditionally (without applying VLAN rules) to ports with the spanning tree disabled and BPDU handling mode of flooding. Tagged BPDU packets are filtered.Spanning-Tree Commands 465 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The spanning-tree bpdu (Global) command determines the default configuration. Command Mode Interface Configuration (Ethernet, Port-channel) mode Example The following example defines the BPDU packet as flooding when the spanning tree is disabled on gigabitethernet port 1/0/3. Console(config)# interface gi1/0/3 Console(config-if)# spanning-tree bpdu flooding spanning-tree guard root Use the spanning-tree guard root Interface Configuration (Ethernet, Portchannel) mode command to enable root guard on all spanning-tree instances on the interface. Root guard prevents the interface from becoming the root port of the device. Use the no form of this command to disable the root guard on the interface. Syntax spanning-tree guard root no spanning-tree guard root Default Configuration Root guard is disabled. Command Mode Interface Configuration (Ethernet, Port-channel) mode User Guidelines Root guard can be enabled when the device operates in STP, RSTP and MSTP modes.466 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY When root guard is enabled, the port changes to the alternate state if the spanning-tree calculations select the port as the root port. Example The following example prevents gigabitethernet port 1/0/1 from being the root port of the device. Console(config)# interface gi1/0/1 Console(config-if)# spanning-tree guard root spanning-tree bpduguard Use the spanning-tree bpduguard Interface Configuration (Ethernet, portchannel) mode command to shut down an interface when it receives a bridge protocol data unit (BPDU). Use the no form of this command to restore the default configuration. Syntax spanning-tree bpduguard {enable | disable} no spanning-tree bpduguard Parameters enable—Enables BPDU Guard. disable—Disables BPDU Guard. Default Configuration BPDU Guard is disabled. Command Mode Interface Configuration (Ethernet, Port-channel) mode User Guidelines The command can be enabled when the spanning tree is enabled (useful when the port is in the PortFast mode) or disabled.Spanning-Tree Commands 467 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example shuts down Ethernet port 1/0/5 when it receives a BPDU. Console(config)# interface gi1/0/5 Console(config-if)# spanning-tree bpduguard enable clear spanning-tree detected-protocols Use the clear spanning-tree detected-protocols Privileged EXEC command to restart the protocol migration process (force the renegotiation with neighboring switches) on all interfaces or on the specified interface Syntax clear spanning-tree detected-protocols [interface interface-id] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode Privileged EXEC mode User Guidelines This feature should be used only when working in RSTP or MSTP mode. Example console# clear spanning-tree detected-protocols spanning-tree mst priority Use the spanning-tree mst priority Global Configuration mode command to configure the device priority for the specified spanning-tree instance. Use the no form of this command to restore the default configuration.468 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax spanning-tree mst instance-id priority priority no spanning-tree mst instance-id priority Parameters • instance-id—Specifies the spanning-tree instance ID. (Range:1–15) • priority—Specifies the device priority for the specified spanning-tree instance. This setting affects the likelihood that the switch is selected as the root switch. A lower value increases the probability that the switch is selected as the root switch. (Range: 0–61440) Default Configuration The default bridge priority for IEEE Spanning Tree Protocol (STP) is 32768. Command Mode Global Configuration mode User Guidelines The priority value must be a multiple of 4096. The switch with the lowest priority is the root of the spanning tree. Example The following example configures the spanning tree priority of instance 1 to 4096. Console(config)# spanning-tree mst 1 priority 4096 spanning-tree mst max-hops Use the spanning-tree mst max-hops Global Configuration mode command to configure the number of hops in an MST region before the BDPU is discarded and the port information is aged out. Use the no form of this command to restore the default configuration. Syntax spanning-tree mst max-hops hop-countSpanning-Tree Commands 469 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY no spanning-tree mst max-hops Parameters hop-count—Specifies the number of hops in an MST region before the BDPU is discarded. (Range: 1–40) Default Configuration The default number of hops is 20. Command Mode Global Configuration mode Example The following example configures the maximum number of hops that a packet travels in an MST region before it is discarded to 10. Console(config)# spanning-tree mst max-hops 10 spanning-tree mst port-priority Use the spanning-tree mst port-priority Interface Configuration (Ethernet, port-channel) mode command to configure the priority of a port. Use the no form of this command to restore the default configuration. Syntax spanning-tree mst instance-id port-priority priority no spanning-tree mst instance-id port-priority Parameters • instance-id—Specifies the spanning tree instance ID. (Range: 1–15) • priority—Specifies the port priority. (Range: 0–240 in multiples of 16) Default Configuration The default port priority for IEEE Spanning Tree Protocol (STP) is 128.470 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Interface Configuration (Ethernet, port-channel) mode User Guidelines The priority value must be a multiple of 16. Example The following example configures the port priority of port gi1/0/1 to 144. Console(config)# interface gi1/0/1 Console(config-if)# spanning-tree mst 1 port-priority 144 spanning-tree mst cost Use the spanning-tree mst cost Interface Configuration (Ethernet, Portchannel) mode command to configure the path cost for multiple spanningtree (MST) calculations. If a loop occurs, the spanning tree considers path cost when selecting an interface to put in the forwarding state. Use the no form of this command to restore the default configuration. Syntax spanning-tree mst instance-id cost cost no spanning-tree mst instance-id cost Parameters • instance-id—Specifies the spanning-tree instance ID. (Range: 1–15) • cost—Specifies the port path cost. (Range: 1–200000000) Default Configuration Default path cost is determined by the port speed and path cost method (long or short) as shown below: Interface Long Short Port-channel 20,000 4 TenGigabit Ethernet (10000 Mbps) 2000 2Spanning-Tree Commands 471 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example configures the MSTP instance 1 path cost for gigabitethernet port 1/0/9 to 4. Console(config)# interface gi1/0/9 Console(config-if)# spanning-tree mst 1 cost 4 spanning-tree mst configuration Use the spanning-tree mst configuration Global Configuration mode command to enable configuring an MST region by entering the Multiple Spanning Tree (MST) mode. Syntax spanning-tree mst configuration Command Mode Global Configuration mode User Guidelines For two or more switches to be in the same MST region, they need to contain the same VLAN mapping, the same configuration revision number, and the same name. Example The following example configures an MST region. Console(config)# spanning-tree mst configuration Console(config-mst)# instance 1 vlan 10-20 Gigabit Ethernet (1000 Mbps) 20,000 4 Fast Ethernet (100 Mbps) 200,000 19 Ethernet (10 Mbps) 2,000,000 100472 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Console(config-mst)# name region1 Console(config-mst)# revision 1 instance (MST) Use instance MST Configuration mode command to map VLANs to an MST instance. Use the no form of this command to restore default mapping. Syntax instance instance-id vlan vlan-range no instance instance-id vlan vlan-range Parameters • instance-id—MST instance (Range: 1–15) • vlan-range—The specified range of VLANs is added to the existing ones. To specify a range, use a hyphen. To specify a series, use a comma. (Range: 1–4094) Default Configuration All VLANs are mapped to the common and internal spanning tree (CIST) instance (instance 0). Command Mode MST Configuration mode User Guidelines All VLANs that are not explicitly mapped to an MST instance are mapped to the common and internal spanning tree (CIST) instance (instance 0) and cannot be unmapped from the CIST. For two or more devices to be in the same MST region, they must have the same VLAN mapping, the same configuration revision number, and the same name.Spanning-Tree Commands 473 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example maps VLANs 10-20 to MST instance 1. Console(config)# spanning-tree mst configuration Console(config-mst)# instance 1 vlan 10-20 name (MST) Use the name MST Configuration mode command to define the MST configuration name. Use the no form of this command to restore the default setting. Syntax name string no name Parameters string—Specifies the MST configuration name. (Length: 1–32 characters) Default Configuration The default name is the bridge address. Command Mode MST Configuration mode Example The following example defines the configuration name as Region1. Console(config)# spanning-tree mst configuration Console(config-mst)# name region1 revision (MST) Use the revision MST Configuration mode command to define the MST configuration revision number. Use the no form of this command to restore the default configuration.474 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax revision value no revision Parameters value—Specifies the MST configuration revision number. (Range: 0–65535) Default Configuration The default configuration revision number is 0. Command Mode MST Configuration mode Example The following example sets the configuration revision to 1. Console(config) # spanning-tree mst configuration Console(config-mst) # revision 1 show (MST) Use the show MST Configuration mode command to displays the current or pending MST region configuration. Syntax show {current | pending} Parameters • current—Displays the current MST region configuration. • pending—Displays the pending MST region configuration. Command Mode MST Configuration modeSpanning-Tree Commands 475 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays a pending MST region configuration. exit (MST) Use the exit MST Configuration mode command to exit the MST region Configuration mode and appy all configuration changes. Syntax exit Command Mode MST Configuration mode Example The following example exits the MST Configuration mode and saves changes. Console(config)# spanning-tree mst configuration Console(config-mst)# exit Console(config)# Console(config-mst)# show pending Pending MST configuration Name: Region1 Revision: 1 Instance -------- 0 1 Vlans Mapped ------------ 1-9,21-4094 10-20 State ------- Enabled Enabled476 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY abort (MST) Use the abort MST Configuration mode command to exit the MST Configuration mode without applying the configuration changes. Syntax abort Command Mode MST Configuration mode Example The following example exits the MST Configuration mode without saving changes. Console(config)# spanning-tree mst configuration Console(config-mst)# abort show spanning-tree Use the show spanning-tree Privileged EXEC mode command to display the spanning-tree configuration. Syntax show spanning-tree [interface-id] [instance instance-id] show spanning-tree [detail] [active | blockedports] [instance instance-id] show spanning-tree mst-configuration Parameters • instance instance-id—Specifies the spanning tree instance ID. (Range: 0–15) • detail—Displays detailed information. • active—Displays active ports only. • blockedports—Displays blocked ports only.Spanning-Tree Commands 477 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY • mst-configuration—Displays the MST configuration identifier. • interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode Privileged EXEC mode Example The following examples display spanning-tree information. Console# show spanning-tree Spanning tree enabled mode RSTP Default port cost method: long Loopback guard: Disabled Root ID Priority Address Path Cost Root Port 32768 00:01:42:97:e0:00 20000 gi1/0/1 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority Address 36864 00:02:4b:29:7a:00 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec478 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Interfaces Name --------- gi1/0/1 gi1/0/2 gi1/0/3 gi1/0/4 gi1/0/5 State ------ Enabled Enabled Disabled Enabled Enabled Prio. Nbr ------ 128.1 128.2 128.3 128.4 128.5 Cost ----- 20000 20000 20000 20000 20000 Sts --- FWD FWD - BLK DIS Role ---- Root Desg - Altn - PortFast --------- No No - No - Type ---------- P2p (RSTP) Shared (STP) - Shared (STP) - Console# show spanning-tree Spanning tree enabled mode RSTP Default port cost method: long Root ID Priority Address 36864 00:02:4b:29:7a:00 This switch is the Root. Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec InterfacesSpanning-Tree Commands 479 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Name -------- gi1/0/1 gi1/0/2 gi1/0/3 gi1/0/4 gi1/0/5 State -------- Enabled Enabled Disabled Enabled Enabled Prio.Nbr -------- 128.1 128.2 128.3 128.4 128.5 Cost ----- 20000 20000 20000 20000 20000 Sts --- FWD FWD - FWD DIS Role ---- Desg Desg - Desg - PortFast --------- No No - No - Type ---------- P2p (RSTP) Shared (STP) - Shared (STP) - Console# show spanning-tree Spanning tree disabled (BPDU filtering) mode RSTP Default port cost method: long Root ID Priority Address Path Cost Root Port Hello Time N/A N/A N/A N/A N/A Max Age N/A Forward Delay N/A Bridge ID Priority Address 36864 00:02:4b:29:7a:00 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interfaces480 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Name --------- gi1/0/1 gi1/0/2 gi1/0/3 gi1/0/4 gi1/0/5 State -------- Enabled Enabled Disabled Enabled Enabled Prio.Nbr ------- 128.1 128.2 128.3 128.4 128.5 Cost ----- 20000 20000 20000 20000 20000 Sts --- - - - - - Role ---- - - - - - PortFast --------- - - - - - Type ----- - - - - - Console# show spanning-tree active Spanning tree enabled mode RSTP Default port cost method: long Root ID Priority Address Path Cost Root Port 32768 00:01:42:97:e0:00 20000 gi1/0/1 Hello Time 2 sec Max Age 20 secForward Delay 15 sec Bridge ID Priority Address 36864 00:02:4b:29:7a:00 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec InterfacesSpanning-Tree Commands 481 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Name --------- gi1/0/1 gi1/0/2 gi1/0/4 State -------- - Enabled Enabled Enabled Prio.Nbr -------- - 128.1 128.2 128.4 Cost ----- 20000 20000 20000 Sts --- FWD FWD BLK Role ---- Root Desg Altn PortFast --------- No No No Type ---------- P2p (RSTP) Shared (STP) Shared (STP) Console# show spanning-tree blockedports Spanning tree enabled mode RSTP Default port cost method: long Root ID Priority Address Path Cost Root Port 32768 00:01:42:97:e0:00 20000 gi1/0/1 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority 36864 Address 00:02:4b:29:7a:00 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Interfaces482 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Name --------- gi1/0/4 State -------- - Enabled Prio.Nbr -------- - 128.4 Cost ----- 19 Sts --- BLK Role ---- Altn PortFast --------- No Type ---------- Shared (STP) Console# show spanning-tree detail Spanning tree enabled mode RSTP Default port cost method: long Root ID Priority Address Path Cost Root Port 32768 00:01:42:97:e0:00 20000 gi1/0/1 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Bridge ID Priority Address 36864 00:02:4b:29:7a:00 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Number of topology changes 2 last change occurred 2d18h ago Times: hold 1, topology change 35, notification 2 hello 2, max age 20, forward delay 15 Port 1 (gi1/0/1) enabled State: Forwarding Port id: 128.1 Type: P2p (configured: auto) RSTP Designated bridge Priority: 32768 Designated port id: 128.25 Guard root: Disabled Role: Root Port cost: 20000 Port Fast: No (configured:no) Address: 00:01:42:97:e0:00 Designated path cost: 0 BPDU guard: Disabled Number of transitions to forwarding state: 1 BPDU: sent 2, received 120638Spanning-Tree Commands 483 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Port 2 (gi1/0/2) enabled State: Forwarding Port id: 128.2 Type: Shared (configured: auto) STP Designated bridge Priority: 32768 Designated port id: 128.2 Guard root: Disabled Role: Designated Port cost: 20000 Port Fast: No (configured:no) Address: 00:02:4b:29:7a:00 Designated path cost: 20000 BPDU guard: Disabled Number of transitions to forwarding state: 1 BPDU: sent 2, received 170638 Port 3 (gi1/0/3) disabled State: N/A Port id: 128.3 Type: N/A (configured: auto) Designated bridge Priority: N/A Designated port id: N/A Guard root: Disabled Role: N/A Port cost: 20000 Port Fast: N/A (configured:no) Address: N/A Designated path cost: N/A BPDU guard: Disabled Number of transitions to forwarding state: N/A BPDU: sent N/A, received N/A Port 4 (gi1/0/4) enabled State: Blocking Port id: 128.4 Type: Shared (configured:auto) STP Designated bridge Priority: 28672 Designated port id: 128.25 Guard root: Disabled Role: Alternate Port cost: 20000 Port Fast: No (configured:no) Address: 00:30:94:41:62:c8 Designated path cost: 20000 BPDU guard: Disabled Number of transitions to forwarding state: 1 BPDU: sent 2, received 120638 Port 5 (gi1/0/5) enabled State: Disabled Port id: 128.5 Type: N/A (configured: auto) Designated bridge Priority: N/A Designated port id: N/A Guard root: Disabled Role: N/A Port cost: 20000 Port Fast: N/A (configured:no) Address: N/A Designated path cost: N/A BPDU guard: Disabled484 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Number of transitions to forwarding state: N/A BPDU: sent N/A, received N/A Console# show spanning-tree ethernet gi1/0/1 Port 1 (gi1/0/1) enabled State: Forwarding Port id: 128.1 Type: P2p (configured: auto) RSTP Designated bridge Priority: 32768 Designated port id: 128.25 Guard root: Disabled Role: Root Port cost: 20000 Port Fast: No (configured:no) Address: 00:01:42:97:e0:00 Designated path cost: 0 BPDU guard: Disabled Number of transitions to forwarding state: 1 BPDU: sent 2, received 120638 Console# show spanning-tree mst-configuration Name: Region1 Revision: 1 Instance -------- 0 1 Vlans mapped ------------ 1-9, 21-4094 10-20 State --------- Enabled EnabledSpanning-Tree Commands 485 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Console# show spanning-tree Spanning tree enabled mode MSTP Default port cost method: long ###### MST 0 Vlans Mapped: 1-9 CST Root ID Priority Address Path Cost Root Port 32768 00:01:42:97:e0:00 20000 gi1/0/1 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec IST Master ID Priority Address 32768 00:02:4b:29:7a:00 This switch is the IST master. Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Max hops 20 Interfaces Name ---- gi1/0/1 gi1/0/2 gi1/0/3 gi1/0/4 State ------- Enabled Enabled Enabled Enabled Prio.Nbr -------- 128.1 128.2 128.3 128.4 Cost ----- 20000 20000 20000 20000 Sts --- FWD FWD FWD FWD Role ---- Root Desg Desg Desg PortFast -------- No No No No Type --------------- P2p Bound (RSTP) Shared Bound (STP) P2p P2p486 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY ###### MST 1 Vlans Mapped: 10-20 Root ID Priority Address Path Cost Root Port Rem hops 24576 00:02:4b:29:89:76 20000 gi1/0/4 19 Bridge ID Priority Address 32768 00:02:4b:29:7a:00 Interfaces Name ---- gi1/0/1 gi1/0/2 gi1/0/3 gi1/0/4 State ------- Enabled Enabled Enabled Enabled Prio.Nbr -------- 128.1 128.2 128.3 128.4 Cost ----- 20000 20000 20000 20000 Sts --- FWD FWD BLK FWD Role ---- Boun Boun Altn Root PortFast -------- No No No No Type --------------- P2p Bound (RSTP) Shared Bound (STP) P2p P2p Console# show spanning-tree detail Spanning tree enabled mode MSTP Default port cost method: long ###### MST 0 Vlans Mapped: 1-9 CST Root ID Priority Address Path Cost Root Port 32768 00:01:42:97:e0:00 20000 gi1/0/1 Hello Time 2 sec Max Age 20 sec Forward Delay 15 secSpanning-Tree Commands 487 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY IST Master ID Priority Address 32768 00:02:4b:29:7a:00 This switch is the IST master. Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Max hops 20 Number of topology changes 2 last change occurred 2d18h ago Times: hold 1, topology change 35, notification 2 hello 2, max age 20, forward delay 15 Port 1 (gi1/0/1) enabled State: Forwarding Port id: 128.1 Type: P2p (configured: auto) Boundary RSTP Designated bridge Priority: 32768 Designated port id: 128.25 Number of transitions to forwarding state: 1 BPDU: sent 2, received 120638 Role: Root Port cost: 20000 Port Fast: No (configured:no) Address: 00:01:42:97:e0:00 Designated path cost: 0 Port 2 (gi1/0/2) enabled State: Forwarding Port id: 128.2 Type: Shared (configured: auto) Boundary STP Designated bridge Priority: 32768 Designated port id: 128.2 Number of transitions to forwarding state: 1 BPDU: sent 2, received 170638 Role: Designated Port cost: 20000 Port Fast: No (configured:no) Address: 00:02:4b:29:7a:00 Designated path cost: 20000488 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Port 3 (gi1/0/3) enabled State: Forwarding Port id: 128.3 Type: Shared (configured: auto) Internal Designated bridge Priority: 32768 Designated port id: 128.3 Number of transitions to forwarding state: 1 BPDU: sent 2, received 170638 Role: Designated Port cost: 20000 Port Fast: No (configured:no) Address: 00:02:4b:29:7a:00 Designated path cost: 20000 Port 4 (gi1/0/4) enabled State: Forwarding Port id: 128.4 Type: Shared (configured: auto) Internal Designated bridge Priority: 32768 Designated port id: 128.2 Number of transitions to forwarding state: 1 BPDU: sent 2, received 170638 Role: Designated Port cost: 20000 Port Fast: No (configured:no) Address: 00:02:4b:29:7a:00 Designated path cost: 20000 ###### MST 1 Vlans Mapped: 10-20 Root ID Priority Address Path Cost Root Port 24576 00:02:4b:29:89:76 20000 gi1/0/4 Rem hops 19 Bridge ID Priority Address 32768 00:02:4b:29:7a:00 Number of topology changes 2 last change occurred 1d9h ago Times: hold 1, topology change 2, notification 2 hello 2, max age 20, forward delay 15Spanning-Tree Commands 489 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Port 1 (gi1/0/1) enabled State: Forwarding Port id: 128.1 Type: P2p (configured: auto) Boundary RSTP Designated bridge Priority: 32768 Designated port id: 128.1 Number of transitions to forwarding state: 1 BPDU: sent 2, received 120638 Role: Boundary Port cost: 20000 Port Fast: No (configured:no) Address: 00:02:4b:29:7a:00 Designated path cost: 20000 Port 2 (gi1/0/2) enabled State: Forwarding Port id: 128.2 Type: Shared (configured: auto) Boundary STP Designated bridge Priority: 32768 Designated port id: 128.2 Number of transitions to forwarding state: 1 BPDU: sent 2, received 170638 Role: Designated Port cost: 20000 Port Fast: No (configured:no) Address: 00:02:4b:29:7a:00 Designated path cost: 20000 Port 3 (gi1/0/3) disabled State: Blocking Port id: 128.3 Type: Shared (configured: auto) Internal Designated bridge Priority: 32768 Designated port id: 128.78 Number of transitions to forwarding state: 1 BPDU: sent 2, received 170638 Role: Alternate Port cost: 20000 Port Fast: No (configured:no) Address: 00:02:4b:29:1a:19 Designated path cost: 20000 Port 4 (gi1/0/4) enabled State: Forwarding Port id: 128.4 Type: Shared (configured: auto) Internal Designated bridge Priority: 32768 Designated port id: 128.2 Number of transitions to forwarding state: 1 BPDU: sent 2, received 170638 Role: Designated Port cost: 20000 Port Fast: No (configured:no) Address: 00:02:4b:29:7a:00 Designated path cost: 20000490 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Console# show spanning-tree Spanning tree enabled mode MSTP Default port cost method: long ###### MST 0 Vlans Mapped: 1-9 CST Root ID Priority Address Path Cost Root Port 32768 00:01:42:97:e0:00 20000 gi1/0/1 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec IST Master ID Priority Address Path Cost Rem hops 32768 00:02:4b:19:7a:00 10000 19 Bridge ID Priority Address 32768 00:02:4b:29:7a:00 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Max hops 20 Console# show spanning-tree Spanning tree enabled mode MSTP Default port cost method: long ###### MST 0 Vlans Mapped: 1-9 CST Root ID Priority Address 32768 00:01:42:97:e0:00 This switch is root for CST and IST master.Spanning-Tree Commands 491 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show spanning-tree bpdu Use the show spanning-tree bpdu EXEC mode command to display the BPDU handling when spanning-tree is disabled. Syntax show spanning-tree bpdu [interface-id] Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ethernet port or Port-channel. Command Mode EXEC mode Example The following examples display spanning-tree information. Root Port gi1/0/1 Hello Time 2 sec Max Age 20 sec Forward Delay 15 sec Max hops 20 Console# show spanning-tree bpdu Global: Flooding Interface --------- gi1/0/1 gi1/0/2 gi1/0/3 Admin Mode ---------- Global Global Flooding Oper Mode --------- Flooding STP STP492 Spanning-Tree Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\Spanning-Tree.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LYVLAN Commands 493 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 31 VLAN Commands vlan database Use the vlan database Global Configuration mode command to enter the VLAN Configuration mode. Syntax vlan database Command Mode Global Configuration mode Example The following example enters the VLAN database mode. Console(config)# vlan database Console(config-vlan)# vlan Use the vlan VLAN Configuration mode command to create a VLAN. Use the no form of this command to restore the default configuration or delete a VLAN. Syntax vlan vlan-range [name vlan-name] no vlan vlan-range The device accepts also the following syntax:494 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY vlan vlan-range [name vlan-name] [media ethernet] [state active] no vlan vlan-range Parameters • vlan-range—Specifies a list of VLAN IDs to add. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. • name—Specifies the VLAN name. The option is only valid in cass where only one VLAN is configured by the command (Range: 1–32 characters) Command Mode VLAN Configuration mode Example The following example creates VLAN number 1972. Console(config)# vlan database Console(config-vlan)# vlan 1972 interface vlan Use the interface vlan Global Configuration mode command to enter the Interface Configuration (VLAN) mode and enable configuration of the specified VLAN ID. Syntax interface vlan vlan-id Parameters vlan-id—Specifies an existing VLAN ID. Command Mode Global Configuration modeVLAN Commands 495 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines If the VLAN does not exist (ghost VLAN), not all of the commands are available under the interface VLAN context. The commands that are supported for VLANs that do not exist are: • IGMP snooping control commands • Bridge multicast configuration commands Example The following example configures VLAN 1 with IP address 131.108.1.27 and subnet mask 255.255.255.0. Console (config)# interface vlan 1 Console (config-if)# ip address 131.108.1.27 255.255.255.0 interface range vlan Use the interface range vlan Global Configuration mode command to enable configuring multiple VLANs simultaneously. Syntax interface range vlan vlan-range Parameters vlan-range—Specifies a list of VLAN IDs. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. Command Mode Global Configuration mode User Guidelines Commands under the interface range context are executed independently on each interface in the range. If the command returns an error on one of the interfaces, an error message is displayed and command execution continues on the other interfaces.496 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example groups VLANs 221 through 228 and 889 to receive the same command. Console(config)# interface range vlan 221-228, vlan 889 Console(config-if)# name Use the name Interface Configuration (VLAN) mode command to add a name to a VLAN. Use the no form of this command to remove the VLAN name. Syntax name string no name Parameters string—Specifies a unique name associated with this VLAN. (Length: 1–32 characters) Default Configuration No name is defined. Command Mode Interface Configuration (VLAN) mode. It cannot be configured for a range of interfaces (range context). User Guidelines The VLAN name must be unique. Example The following example gives VLAN number 19 the name Marketing. Console(config)# interface vlan 19 Console(config-if)# name MarketingVLAN Commands 497 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY switchport protected-port Use the switchport protected-port Interface Configuration mode command to isolate unicast, multicast, and broadcast traffic at Layer 2 from other protected ports on the same switch. Use the no form of this command to disable protection on the port. Syntax switchport protected-port no switchport protected-port Parameters This command has no arguments or keywords. Default Configuration Unprotected Command Mode Interface configuration (Ethernet, port-channel) User Guidelines Use this command to isolate unicast, multicast, and broadcast traffic at Layer 2 from other protected ports (that are not associated with the same community as the ingress interface) on the same switch. Please note that the packet is still subject to FDB decision and to all filtering rules. Use the switchport community Interface Configuration command to associate the interface with a community. Example console(config)# interface gi1/0/1 console(config-if)# switchport protected-port498 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY switchport community Use the switchport community Interface Configuration mode command to associate a protected port with a community. Use the no form of this command to return to default. Syntax switchport community community no switchport community Parameters community—Specifies the community number. (Range:1 - 30) Default Configuration The port is not associated with any community. Command Mode Interface Configuration (Ethernet, port-channel) mode User Guidelines The command is relevant only when the port is defined as a protected port. Use the switchport protected-port Interface Configuration command to define a port as a protected port. Example console(config)# interface gi1/0/1 console(config-if)# switchport community 1 show interfaces protected-ports Use the show interfaces protected-ports EXEC mode command to show protected ports configuration. Syntax show interfaces protected-ports [interface-id]VLAN Commands 499 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ehernet port or Port-channel. Command Mode EXEC mode Example console# show interfaces protected-ports Interface State Community --------- ------------- --------- gi1/0/1 Protected 1 gi1/0/2 Protected Isolated gi1/0/3 Unprotected 20 gi1/0/4 Unprotected Isolated Note: The Community column for unprotected ports is relevant only when the port state is changed to Protected. switchport Use the switchport Interface Configuration mode command with no keywords to put an interface that is in Layer 3 mode into Layer 2 mode for Layer 2 configuration. Use the no form of this command to put an interface in Layer 3 mode. Syntax switchport no switchport Default Configuration Layer 2 mode500 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Command Mode Interface Configuration (Ethernet, port-channel) mode switchport mode Use the switchport mode Interface Configuration (Ethernet, port-channel) mode command to configure the VLAN membership mode of a port. Use the no form of this command to restore the default configuration. Syntax switchport mode { access | trunk | general | private-vlan {promiscuous | host} | customer } no switchport mode Parameters • access—Specifies an untagged layer 2 VLAN port. • trunk—Specifies a trunking layer 2 VLAN port. • general—Specifies a full 802-1q supported VLAN port. • customer—Specifies that the port is connected to customer equipment. Used when the switch is in a provider network. • private-vlan promiscous—Private-VLAN promiscous port. • private-vlan host—Private-VLAN host port. Default Configuration Command Mode Interface Configuration (Ethernet, port-channel) mode User Guidelines • When the port mode is changed, it receives the configuration corresponding to the mode. • If the port mode is changed to access and the access VLAN does not exist, then the port will not belongs to any VLAN.VLAN Commands 501 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example configures gigabitethernet port 1/0/1 as an untagged layer 2 VLAN port. Console(config)# interface gi1/0/1 Console(config-if)# switchport mode access switchport access vlan Use the switchport access vlan Interface Configuration (Ethernet, portchannel) mode command to configure the VLAN ID when the interface is in access mode. Use the no form of this command to restore the default configuration. Syntax switchport access vlan { vlan-id | none } no switchport access vlan Parameters vlan-id—Specifies the VLAN ID to which the port is configured. none—Specifies the access port cannot belong to any VLAN. Default Configuration If the default VLAN is enabled, the VLAN ID is 1. Otherwise, it is not a member of any VLAN. Command Mode Interface Configuration (Ethernet, port-channel) mode User Guidelines The command automatically removes the port from the previous VLAN and adds it to the new VLAN.502 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example configures a VLAN ID of 23 to the untagged layer 2 VLAN gigabitethernet port 1/0/1. Console(config)# interface gi1/0/1 Console(config-if)# switchport access vlan 23 switchport access multicast-tv vlan Use the switchport access multicast-tv vlan Interface Configuration (Ethernet, Port-channel) mode command to enable receiving multicast transmissions from a VLAN that is not the Access port VLAN, while keeping the L2 segregation with subscribers on different Access port VLANs. Use the no form of this command to disable receiving multicast transmissions. Syntax switchport access multicast-tv vlan vlan-id no switchport access multicast-tv vlan Parameters vlan-id—Specifies the Multicast TV VLAN ID. Default Configuration Receiving multicast transmissions is disabled. Command Mode Interface Configuration (Ethernet, Port-channel) mode User Guidelines The user cannot transmit multicast transmissions on the multicast TV VLAN. A multicast TV VLAN cannot be enabled if a Guest VLAN is enabled on the interface.VLAN Commands 503 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example enables gigabitethernet port 1/0/5 to receive multicast transmissions from VLAN 11. Console(config)# interface gi1/0/5 Console(config-if)# switchport access multicast-tv vlan 11 switchport trunk allowed vlan Use the switchport trunk allowed vlan Interface Configuration mode command to set the trunk characteristics when the interface is in trunking mode. Use the no form of this command to reset a trunking characteristic to the default. Syntax switchport trunk allowed vlan { all | none | add vlan-list | remove vlan-list | except vlan-list } no switchport trunk allowed vlan Parameters all—Specifies all VLANs from 1 to 4094. At any time, the port belongs to all VLANs exiting at the time. (Range: 1–4094) none—Specifies an empty VLAN list The port does not belong to any VLAN. add vlan-list—List of VLAN IDs to add. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. remove vlan-list—List of VLAN IDs to remove. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. except vlan-list—List of VLAN IDs is calculated by inverting the defined list of VLANs (the calculated list will include all VLANs from interval 1..4094 except VLANs from the defined list.504 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration The Default VLAN is its Native VLAN and the port belongs to either all VLANs or only to the Default VLAN depending on a value of parameter Trunk Port Default Configuration. Command Mode Interface Configuration (Ethernet, port-channel) mode User Guidelines The RS port model behavior allows only the following options: Add and Remove. Inside except vlan-list is saved as add ~ vlan-list, where ~ vlan-list is a list of all VLANs from 1 to 4094 minus the VLANs from vlan-list. Command show running/startup always uses the latter format. The port must be in trunk mode before the command can take effect. Example console(config)# interface gi1/0/1 console(config-if)# switchport mode trunk console(config-if)# switchport trunk allowed vlan all switchport trunk native vlan Use the switchport trunk native vlan Interface Configuration (Ethernet, port-channel) mode command to define the native VLAN when the interface is in trunk mode. Use the no form of this command to restore the default configuration. Syntax switchport trunk native vlan { vlan-id | none } no switchport trunk native vlan Parameters • vlan-id—Specifies the native VLAN ID. • none—Specifies the access port cannot belong to any VLAN.VLAN Commands 505 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration If the default VLAN is enabled, the VLAN ID is 1. Otherwise, the VLAN ID is 4095. Command Mode Interface Configuration (Ethernet, port-channel) mode User Guidelines The command adds the port as a member of the VLAN. If the port is already a member of the VLAN (not a native), it must first be removed from the VLAN. Example The following example configures VLAN number 123 as the native VLAN when the port is in trunk mode. Console# interface gi1/0/1 Console(config-if)# switchport trunk native vlan 123 switchport general allowed vlan Use the switchport general allowed vlan Interface Configuration mode command to set the general characteristics when the interface is in general mode. Use the no form of this command to reset a general characteristic to the default. Syntax switchport general allowed vlan {add | remove} vlan-list [tagged|untagged] no switchport general allowed vlan Parameters • add vlan-list—List of VLAN IDs to add. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. (Range: 1–4094)506 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • remove vlan-list—List of VLAN IDs to remove. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. • tagged - Specify that packets would be transmitted tagged for the configured VLANs • untagged - Specify that packets would be transmitted untagged for the configured VLANs (this is the default) Default Configuration The port’s PVID equals to the Default VLAN ID and belongs to the Default VLAN as untagged one. Command Mode Interface Configuration mode Example console(config-if)# interface gi1/0/1 console(config-if)# switchport mode general console(config-if)# switchport general allowed vlan add 2-3 tagged switchport general pvid Use the switchport general pvid Interface Configuration (Ethernet, Portchannel) mode command to configure the Port VLAN ID (PVID) when the interface is in general mode. Use the no form of this command to restore the default configuration. Syntax switchport general pvid vlan-id no switchport general pvid Parameters vlan-id—Specifies the Port VLAN ID (PVID).VLAN Commands 507 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Default Configuration If the default VLAN is enabled, PVID is 1. Otherwise, PVID is =4095. Command Mode Interface Configuration (Ethernet, Port-channel) mode Example The following example configures PVID 234 for gigabitethernet port 1/0/2, when the interface is in general mode. Console(config)# interface gi1/0/2 Console(config-if)# switchport mode general Console(config-if)# switchport general pvid 234 switchport general ingress-filtering disable Use the switchport general ingress-filtering disable Interface Configuration (Ethernet, Port-channel) mode command to disable port ingress filtering. Use the no form of this command to restore the default configuration. Syntax switchport general ingress-filtering disable no switchport general ingress-filtering disable Default Configuration Ingress filtering is enabled. Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example disables port ingress filtering on gigabitethernet port 1/0/1. Console(config)# interface gi1/0/1 Console(config-if)# switchport mode general508 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Console(config-if)# switchport general ingress-filtering disable switchport general acceptable-frame-type Use the switchport general acceptable-frame-type Interface Configuration mode command to configure ingress filtering based on packet type tagged/untagged. Use the no form of this command to return to default. Syntax switchport general acceptable-frame-type {tagged-only | untagged-only | all} no switchport general acceptable-frame-type Parameters • tagged-only—Discard untagged packets and priority tagged packets. • untagged-only—Discard VLAN tagged packets (not including Priority tagged packets) • all—Do not discard packets based on whether the packet is VLAN tagged or not. Default Configuration All frame types are accepted at ingress. Command Mode Interface Configuration (Ethernet, port-channel) mode Example The following example configures gigabitethernet port 1/0/3 to discard untagged frames at ingress. Console(config)# interface gi1/0/3 Console(config-if)# switchport mode general Console(config-if)# switchport general acceptable-frame-type tagged-onlyVLAN Commands 509 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY switchport customer vlan Use the switchport customer vlan Interface Configuration (Ethernet, Portchannel) mode command to set the port's VLAN when the interface is in customer mode. Use the no form of this command to restore the default configuration. Syntax switchport customer vlan vlan-id no switchport customer vlan Parameters vlan-id—Specifies the customer VLAN ID. Default Configuration No VLAN is configured. Command Mode Interface Configuration (Ethernet, Port-channel) mode Example The following example defines gigabitethernet port 1/0/5 as a member of customer VLAN 5. Console(config)# interface gi1/0/5 Console(config-if)# switchport mode custmer Console(config-if)# switchport customer vlan isolated 5 switchport general forbidden vlan Use the switchport general forbidden vlan Interface Configuration (Ethernet, Port-channel) mode command to forbid adding or removing specific VLANs to or from a port. Use the no form of this command to restore the default configuration.510 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax switchport general forbidden vlan {add vlan-list | remove vlan-list} no switchport general forbidden vlan {add vlan-list | remove vlan-list} Parameters • add vlan-list—Specifies a list of VLAN IDs to add. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen to designate a range of IDs. • remove vlan-list—Specifies a list of VLAN IDs to remove. Separate nonconsecutive VLAN IDs with a comma and no spaces. Use a hyphen designate a range of IDs. Default Configuration All VLANs are allowed. Command Mode Interface Configuration (Ethernet, Port-channel) mode Example The following example forbids adding VLAN IDs 234 to 256 to gigabitethernet port 1/0/7. Console(config)# interface gi1/0/7 Console(config-if)# switchport mode general Console(config-if)# switchport general forbidden vlan add 234- 256 map protocol protocols-group Use the map protocol protocols-group VLAN Configuration mode command to map a protocol to a group of protocols. Use the no form of this command to delete a protocol from a group. Syntax map protocol protocol [encapsulation] protocols-group group no map protocol protocol [encapsulation]VLAN Commands 511 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • protocol—Specifies a 16-bit protocol number or one of the reserved names listed in the User Guidelines. (Range: 0x0600–0xFFFF) • encapsulation—Specifies one of the following values: Ethernet, rfc1042, llcOther. If no option is indicated, the default is Ethernet. • protocols-group group—Specifies the group number of the group of protocols associated together. (Range: 1–2147483647) Default Configuration The default encapsulation is Ethernet. Command Mode VLAN Configuration mode User Guidelines The value 0x8100 is not valid as the protocol number for Ethernet encapsulation. The following protocol names are reserved for Ethernet Encapsulation: • ip • arp • ipv6 • ipx Example The following example maps protocol ip to protocol group number 213. Console(config)# vlan database Console(config-vlan)# map protocol ip protocols-group 213 switchport general map protocols-group vlan Use the switchport general map protocols-group vlan Interface Configuration (Ethernet, Port-channel) mode command to set a protocolbased classification rule. Use the no form of this command to delete a classification.512 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax switchport general map protocols-group group vlan vlan-id no switchport general map protocols-group group Parameters • group—Specifies the group number as defined in the map protocol protocols-group command. (Range: 1–65535) • vlan-id—Defines the VLAN ID in the classifying rule. Command Mode Interface Configuration (Ethernet, port-channel) mode Default Configuration No classification is defined. User Guidelines The VLAN classification rule priorities are: 1. MAC-based VLAN (Best match among the rules) 2. Subnet-based VLAN (Best match among the rules) 3. Protocol-based VLAN 4. PVID Example The following example sets a protocol-based classification rule. Console(config-if)# switchport general map protocols-group 1 vlan 8 private-vlan Use the private-vlan Interface VLAN Configuration mode command to configure a private VLAN. Use the no form of this command to return the VLAN to normal VLAN configuration.VLAN Commands 513 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax private-vlan {primary | isolated} no private-vlan Parameters • Primary—Designate the VLAN as Primary VLAN. • Isolated—Designate the VLAN as Isolated VLAN. Default Configuration No private VLANs are configured. Command Mode Interface Configuration (VLAN) mode User Guidelines • The VLAN type cannot be changed if there is a private-VLAN port that is a member in the VLAN. • The VLAN type cannot be changed if it is associated with other private VLANs. • The VLAN type is not kept as a property of the VLAN when it is deleted. private-vlan association Use the private-vlan association Interface VLAN Configuration mode command to configure the association between the primary VLAN and the secondary VLANs. Use the no form of this command to remove the association. Syntax private-vlan association [add | remove] secondary-vlan-list no private-vlan association Parameters • add—Associates a secondary VLAN to a primary VLAN. This is the default action.514 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • remove—Clears the association between a secondary VLAN and a primary VLAN. • secondary-vlan-list—Specifies one or more secondary VLANs to be associated with a primary VLAN in a private VLAN. Default Configuration No private VLANs are configured. Command Mode Interface Configuration (VLAN) mode User Guidelines • The command can only be executed in the context of the primary VLAN. • Private VLAN cannot be removed or change its type if it is associated with other private VLANs. • Primary VLAN can be associated with only single isolated VLAN. • A secondary VLAN can be associated with only one primary VLAN. • The association of secondary VLANs with a primary VLAN cannot be removed if there are private VLAN ports that are members in the secondary VLAN. • In MSTP mode, all the VLANs that are associated with a private VLAN should be mapped to the same instance. switchport private-vlan mapping Use the switchport private-vlan mapping Interface Configuration mode command to configure the VLANs of the private-vlan promiscuous port. Use the no form of this command to reset to default. Syntax switchport private-vlan mapping primary-vlan-id [add | remove] secondaryvlan-list no switchport private-vlan mappingVLAN Commands 515 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters • primary-vlan-id—The VLAN ID of the primary VLAN. • secondary-vlan-list—Specifies one or more secondary VLANs. Default Configuration No VLAN is configured. Command Mode Interface Configuration (Ethernet, port-channel) mode User Guidelines The secondary VLANs should be associated with the primary VLANs, otherwise the configuration is not accepted. See the command private-vlan association. switchport private-vlan host-association Use the switchport private-vlan host-association Interface Configuration mode command to configure the VLANs of the private-vlan host port. Use the no form of this command to reset to default. Syntax switchport private-vlan host-association primary-vlan-id secondary-vlan-id no switchport private-vlan host-association Parameters • primary-vlan-id—The VLAN ID of the primary VLAN. • secondary-vlan-list—Specifies the secondary VLANs. The secondary VLAN is an isolated port. Default Configuration No VLAN is configured. Command Mode Interface Configuration (Ethernet, port-channel) mode516 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY User Guidelines The secondary VLAN should be associated with the primary VLANs, otherwise the configuration is not accepted. See the command private-vlan association. show vlan private-vlan Use the show vlan private-vlan EXEC mode command to show the private VLANs information. Syntax show vlan private-vlan [tag vlan-id ] Parameters vlan-id—VLAN ID Command Mode EXEC mode User Guidelines The show command does not include non-private-vlan ports that are members in private VLANs. Example Console# show vlan private-vlan Primary Secondary Type Ports ----------- ----------- ----------- ---------------------- 150 primary gi1/0/15 150 151 isolated gi1/0/15 ip internal-usage-vlan Use the ip internal-usage-vlan Interface Configuration (Ethernet, Portchannel) mode command to reserve a VLAN as the internal usage VLAN of VLAN Commands 517 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY an interface. Use the no form of this command to restore the default configuration. Syntax ip internal-usage-vlan vlan-id no ip internal-usage-vlan Parameters vlan-id—Specifies the internal usage VLAN ID. Command Mode Interface Configuration (Ethernet, Port-channel) mode. It cannot be configured for a range of interfaces (range context). User Guidelines An internal usage VLAN is required when an IP interface is defined on an Ethernet port or Port-channel. Use this command to define the internal usage VLAN of a port. If an internal usage VLAN is not defined for a port, the software chooses one of the unused VLANs. If a VLAN ID was chosen by the software for internal usage, but it is desired to use that VLAN ID for a static or dynamic VLAN, do one of the following: • Remove the IP interface, create the VLAN, and recreate the IP interface. • Use this command to explicitly define the internal usage VLAN. Example The following example reserves unused VLAN 200 as the internal usage VLAN of Ethernet port 1/3gigabitethernet port 1/0/3. Console(config)# interface gi1/0/3 Console(config-if)# ip internal-usage-vlan 200518 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY show vlan Use the show vlan Privileged EXEC mode command to display VLAN information for all VLANs or for a specific VLAN. Syntax show vlan [tag vlan-id | name vlan-name] Parameters • tag vlan-id—Specifies a VLAN ID. • name vlan-name—Specifies a VLAN name string. (Length: 1–32 characters) Command Mode Privileged EXEC mode Example The following example displays information for all VLANs. Console# show vlan VLAN ---- 1 10 11 20 21 30 31 91 3978 Name ---------- default VLAN0010 VLAN0011 VLAN0020 VLAN0021 VLAN0030 VLAN0031 VLAN0091 Guest VLAN Ports -------- gi1/0/1-2 gi1/0/3-4 gi1/0/1-2 gi1/0/3-4 gi1/0/1-2 gi1/0/17 Type ------- Other dynamic static static static static static static static Authorization -------------- Required Required Required Required Required Required Required Not Required GuestVLAN Commands 519 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY show vlan multicast-tv Use the show vlan multicast-tv EXEC mode command to display information on the source ports and receiver ports of multicast-TV VLAN. Syntax show vlan multicast-tv vlan vlan-id Parameters vlan-id—Specifies the VLAN ID. Command Mode EXEC mode Example The following example displays information on the source and receiver ports of multicast-TV VLAN ID 1000. The following table describes the significant fields shown in the display: show vlan protocols-groups Use the show vlan protocols-groups EXEC mode command to display protocols-groups information. Console # show vlan multicast-tv vlan 1000 Source ports ------------- gi1/0/8, gi1/0/9 Receiver Ports ---------------------- gi1/0/1-18, gi1/0/1-18, gi1/0/1-18 Field Description Source ports Ports that can transmit and receive traffic to and from the VLAN. Receiver ports Ports that can only receive traffic from the VLAN.520 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax show vlan protocols-groups Command Mode EXEC mode Example The following example displays protocols-groups information. show vlan internal usage Use the show vlan internal usage Privileged EXEC mode command to display a list of VLANs used internally by the device. Syntax show vlan internal usage Command Mode Privileged EXEC mode Console> show vlan protocols-groups Protocol ------------- 0x800 (IP) 0x806 (ARP) 0x86dd (IPv6) 0x8898 Encapsulation -------------- Ethernet Ethernet Ethernet Ethernet Group -------- 1 1 2 3VLAN Commands 521 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Example The following example displays VLANs used internally by the device. show interfaces switchport Use the show interfaces switchport Privileged EXEC command to display the administrative and operational status of all interfaces or a specific interface. Syntax show interfaces switchport [interface-id] Parameters Interface-id—Specifies an interface ID. The interface ID can be one of the following types: Ehernet port or Port-channel. Example console# show interfaces switchport gi2/0/1 Gathering information... Name: gi1/0/1 Switchport: enable Administrative Mode: access Operational Mode: down Access Mode VLAN: 1 Access Multicast TV VLAN: none Console# show vlan internal usage VLAN -------- 1007 1008 1009 Usage -------- Eth 1/21 Eth 1/22 Eth 1/23 IP address ---------- Active Inactive Active Reserved ---------- No Yes Yes522 VLAN Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\VLAN_ISCLI_Only.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Trunking Native Mode VLAN: 1 Trunking VLANs Enabled: 1 2-4094 (Inactive) General PVID: 1 General VLANs Enabled: none General Egress Tagged VLANs Enabled: none General Forbidden VLANs: none General Ingress Filtering: enabled General Acceptable Frame Type: all General GVRP status: disabled General GVRP VLANs: none Customer Mode VLAN: none Private-vlan promiscuous-association primary VLAN: none Private-vlan promiscuous-association Secondary VLANs Enabled: none Private-vlan host-association primary VLAN: none Private-vlan host-association Secondary VLAN Enabled: none DVA: disable Protected: Enabled, Uplink is gi1/0/1 Classification rules: Classification type Group ID VLAN ID ------------------- -------- ------- Protocol 1 19 Protocol 1 20 Protocol 2 72 Subnet 1 15 MAC 6 11IGMP Snooping Commands 523 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\IGMP_Snooping.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY 32 IGMP Snooping Commands ip igmp snooping (Global) Use the ip igmp snooping Global Configuration mode command to enable Internet Group Management Protocol (IGMP) snooping. Use the no form of this command to disable IGMP snooping. Syntax ip igmp snooping no ip igmp snooping Default Configuration IGMP snooping is disabled. Command Mode Global Configuration mode Example The following example enables IGMP snooping. Console(config)# ip igmp snooping ip igmp snooping vlan Use the ip igmp snooping vlan Global Configuration mode command to enable Internet Group Management Protocol (IGMP) snooping on a specific VLAN. Use the no form of this command to disable IGMP snooping on a VLAN interface.524 IGMP Snooping Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\IGMP_Snooping.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY Syntax ip igmp snooping vlan vlan-id no ip igmp snooping vlan vlan-id Parameters vlan-id—Specifies the VLAN. Default Disabled Command Mode Global Configuration mode User Guidelines IGMP snooping can be enabled only on static VLANs. IGMPv1, IGMPv2 and IGMPv3 are supported. To activate IGMP snooping, the bridge multicast filtering should be enabled. The User Guidelines of the bridge multicast mode Interface VLAN Configuration command describes the configuration that is written into the FDB as a function of the FDB mode and the IGMP version that is used in the network. Example console(config)# ip igmp snooping vlan 2 ip igmp snooping mrouter Use the ip igmp snooping mrouter Global Configuration mode command to enable automatic learning of multicast router ports. Use the no form of this command to remove the configuration. Syntax ip igmp snooping vlan vlan-id mrouter learn pim-dvmrp no ip igmp snooping vlan vlan-id mrouter learn pim-dvmrpIGMP Snooping Commands 525 FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\IGMP_Snooping.fm D E L L C O N F I D E N T I A L – P R E L I M I N A RY 9 / 1 2 / 1 2 - F O R P R O O F O N LY Parameters vlan-id—Specifies the VLAN. Default Learning pim-dvmrp is enabled. Command Mode Global Configuration mode User Guidelines Multicast router ports are learned based on: • Queries received on the port • PIM/PIMv2 received on the port • DVMRP received on the port • MRDISC received on the port  MOSPF received on the port You can execute the command before the VLAN is created. Example console(config)# ip igmp snooping vlan 1 mrouter learn pim-dvmrp ip igmp snooping mrouter interface Use the ip igmp snooping mrouter interface Global Configuration mode command to define a port that is connected to a multicast router port. Use the no form of this command to remove the configuration. Syntax ip igmp snooping vlan vlan-id mrouter interface interface-list no ip igmp snooping vlan vlan-id mrouter interface interface-list Parameters • vlan-id—Specifies the VLAN.526 IGMP Snooping Commands FILE LOCATION: C:\Users\gina\Desktop\Checkout_new\CLI Folders\Dell Contax CLI\files\IGMP_Snooping.fm D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 9 / 1 2 / 1 2 - F O R P R O O F O N LY • interface-list—Specifies the list of interfaces. The interfaces can be one of the following types: Ethernet port or Port-channel. Default No ports defined Command Mode Global Configuration mode User Guidelines A