Dell Drivers for External OEMR 1850 -> Accéder au site Dell -> Accéder aux CODES PROMO et Bons de réduction Dell -> Voir d'autres manuels Dell Revenir à l'accueil

ou juste avant la balise de fermeture -->

 

 

 

 Drivers for External OEMR 1850

Click here for the latest drivers

Quick Links

BIOS - BIOS

Description Importance Version Released Supported OS Download
Dell Server Custom BIOS, A07
OEM PE1850,BIOS,A07
Recommended A07 5/29/2008 OS Independent    
Dell Server Custom BIOS, A06
OEM Ready 1850, BIOS, A06
Recommended A06 7/25/2007 OS Independent    

 

 

ESM - Firmware

Description Importance Version Released Supported OS Download
Dell BMC Firmware, v.1.83, A10
The Baseboard Management Controller (BMC) flash utility is a tool to update firmware (FW) to the Baseboard Management Controller. This firmware update is a non-destructive update. User data is not affected.
Optional 1.83 6/30/2009 OS Independent    

 

 

Historical Applications - Utility

Description Importance Version Released Supported OS Download
Dell 2161DS Digital Switch, 1.2     10/8/2004 RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS XP

 

 

Historical CMSDK Components - Utility

Description Importance Version Released Supported OS Download
Dell Bundle Applicator, v.2.0.1.65, A01     3/25/2005 WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS XP
Dell Bundle Applicator, v.2.0.0.1006, A00     9/17/2004 WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS XP

 

 

Historical Communication Drivers - Driver

Description Importance Version Released Supported OS Download
Conexant v92 Internal Modem, V92 Lead Free (Cher), v.7.06.00, A01     7/11/2005 WINDOWS SERVER 2003

Historical Communication Drivers - HTML

Description Importance Version Released Supported OS Download
Conexant v92 Internal Modem, V92 Lead Free (Cher), v.1.0, A02     7/15/2005 WINDOWS 2000#WINDOWS SERVER 2003

 

 

Historical Diagnostic Utilities - Diagnostics Utility

Description Importance Version Released Supported OS Download
Dell 32 Bit Diagnostics, v.5052A0, A5052     4/27/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell 32 Bit Diagnostics, v.5053A0, A5053     3/29/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   

 

 

Historical Display Devices - Driver

Description Importance Version Released Supported OS Download
Dell E177FP, A Rev     1/18/2007 WINDOWS VISTA 32-BIT#WINDOWS VISTA 64-BIT
Dell E197FP, A Rev     1/18/2007 WINDOWS VISTA 32-BIT#WINDOWS VISTA 64-BIT
Dell E773c-ULD, A Rev     1/17/2007 WINDOWS VISTA 32-BIT#WINDOWS VISTA 64-BIT
Dell E177FPb, A00     11/5/2006 WINDOWS XP#WINDOWS XP X64
Dell E773c-ULD, A00     11/5/2006 WINDOWS 2000#WINDOWS SERVER 2003 X64#WINDOWS XP#WINDOWS XP X64
Dell E176FPb, V6B01     9/17/2006 WINDOWS 2000#WINDOWS XP#WINDOWS XP X64
Dell E156FPb, V6B01     9/17/2006 WINDOWS 2000#WINDOWS XP#WINDOWS XP X64
Dell E196FPb, V6B01     9/17/2006 WINDOWS 2000#WINDOWS XP#WINDOWS XP X64
Dell E176FPf, V6F01     9/17/2006 WINDOWS 2000#WINDOWS XP#WINDOWS XP X64
Dell E156FPf, V6F01     9/17/2006 WINDOWS 2000#WINDOWS XP
Dell E176FPc, V6C01     9/17/2006 WINDOWS 2000#WINDOWS XP#WINDOWS XP X64
Dell E176FPm, V6M01     9/17/2006 WINDOWS 2000#WINDOWS XP
Dell E156FPc, V6C01     9/17/2006 WINDOWS 2000#WINDOWS XP#WINDOWS XP X64
Dell E773c-ULD, A00     9/12/2006 WINDOWS 2000#WINDOWS SERVER 2003 X64#WINDOWS XP#WINDOWS XP X64
Dell M783c-ULD, A00     4/16/2006 WINDOWS 2000#WINDOWS XP

 

 

Historical Embedded Server Management - Firmware

Description Importance Version Released Supported OS Download
Dell BMC Firmware, v.1.83, A10     6/30/2009 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell BMC Firmware, v.1.72, A09     4/10/2007 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell BMC Firmware, v.1.68, A08     11/22/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell BMC Firmware, v.1.52, A07     4/19/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell BMC Firmware, v.1.40, A05     10/12/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell BMC Firmware, v.1.23, A04     6/21/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
  
Dell Backplane Firmware, v.1.00, A01     6/21/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell BMC Firmware, v.1.23, A03     2/16/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
  
Dell Backplane Firmware, v.1.00, A00     8/13/2004 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
  
Dell BMC Firmware, v.1.07, A02     8/13/2004 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
  

 

 

Historical Fibre Channel - Driver

Description Importance Version Released Supported OS Download
QLogic QLogic Fibre Channel Host Bus Adapter, v.6.90d, A02     6/9/2006 NETWARE
QLogic QLogic Fibre Channel Host Bus Adapter, v.7.07.00, A00     11/17/2005 RED HAT ENTERPRISE LINUX 3
QLogic QLogic Fibre Channel Host Bus Adapter, v.8.01.00, A01     11/17/2005 RED HAT ENTERPRISE LINUX 4

Historical Fibre Channel - Patch/Upgrade

Description Importance Version Released Supported OS Download
Microsoft SCSI Port fix for BSOD 0xD1 for WS03, v.Q883114WS03, A02     11/16/2004 WINDOWS SERVER 2003

 

 

Historical Firmware - Firmware

Description Importance Version Released Supported OS Download
Dell 2161DS Digital Switch, v.3.1.0.0 , 1.3 (A03-00)     9/12/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003
Dell PowerVault 220S/221S SES Firmware, v.E.19, A10     9/11/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
  
Dell PowerVault 220S/221S SES Firmware, v.E.19, A09     4/18/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
  
Dell 180AS/2160AS Analog KVM Switch, v.01.00.02, 1.0 (A00-00)     3/1/2005 NOT APPLICABLE
Dell 2161DS Digital Switch, v.03.00.02, 1.2     10/8/2004 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003
Dell 2161DS Digital Switch, v.2.0.13, A01-00     1/14/2004 RED HAT ENTERPRISE LINUX 2.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#WINDOWS 2000

 

 

Historical FlashBIOS Updates - BIOS

Description Importance Version Released Supported OS Download
Dell Server Custom BIOS, A07     5/29/2008 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell Server Custom BIOS, A06     7/25/2007 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   

 

 

Historical IDE and EIDE - Driver

Description Importance Version Released Supported OS Download
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, CERC ATA 100, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.6.46.2.32, A05     6/7/2005 WINDOWS SERVER 2003
WINDOWS SERVER 2003
WINDOWS SERVER 2003
  
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, CERC ATA 100, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.5.48.0.0, A04     6/7/2005 WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
  
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, CERC ATA 100, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.5.46.0.0, A03     8/11/2004 WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
  

 

 

Historical Network Drivers - Driver

Description Importance Version Released Supported OS Download
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00     12/15/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#SUSE LINUX ES 11#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#SUSE LINUX ES 11#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00     12/15/2009 RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64
RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00     12/15/2009 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64#SUSE LINUX ES 11#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64#SUSE LINUX ES 11#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00     12/15/2009 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00     12/15/2009 WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00     12/15/2009 WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64
WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64
WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.1, A03     9/29/2009 WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.1, A03     9/29/2009 WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64
WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A02     9/11/2009 WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64
WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01     9/8/2009 WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01     9/8/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#SUSE LINUX ES 11#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01     9/8/2009 RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01     9/8/2009 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64#SUSE LINUX ES 11#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01     9/8/2009 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.1, A00     7/7/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#SUSE LINUX ES 11#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.1, A00     7/7/2009 RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.1, A00     7/7/2009 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64#SUSE LINUX ES 11#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A00     4/10/2009 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01     4/10/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01     4/10/2009 RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01     4/10/2009 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01     4/10/2009 WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01     4/10/2009 WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64
WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A03     3/31/2009 WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A03     3/31/2009 WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64
WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A05     3/31/2009 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A02     3/30/2009 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A04     3/30/2009 RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A04     3/30/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02     10/7/2008 WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02     10/7/2008 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02     10/7/2008 RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02     10/7/2008 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02     10/7/2008 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A03     10/7/2008 WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64
WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00     9/2/2008 WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64
WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00     9/2/2008 RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00     9/2/2008 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 10 SP2 X86_64#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00     8/27/2008 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#SUSE LINUX ES 9#SUSE LINUX ES 9 SP4 X86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00     8/27/2008 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A01     8/26/2008 WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A02     5/6/2008 WINDOWS SERVER 2008 X64
WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A02     5/6/2008 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A02     5/6/2008 WINDOWS SERVER 2008 X86
WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A02     5/6/2008 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.51.01, A04     5/5/2008 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.51.01, A04     5/5/2008 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.0/T3.0, A00     4/23/2008 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A03     4/23/2008 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A04     4/23/2008 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A04     4/23/2008 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A00     4/23/2008 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A00     4/23/2008 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A00     4/23/2008 NETWARE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A00     3/18/2008 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A00     3/18/2008 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A00     3/3/2008 WINDOWS SERVER 2008 X86
WINDOWS SERVER 2008 X86
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A00     3/3/2008 WINDOWS SERVER 2008 X64
WINDOWS SERVER 2008 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.51.01, A03     11/20/2007 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.51.01, A03     11/13/2007 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.19.01, A05     8/29/2007 WINDOWS 2000
WINDOWS 2000
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.19.01, A05     8/29/2007 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.19.01, A05     8/29/2007 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A04     7/17/2007 WINDOWS 2000
WINDOWS 2000
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A04     7/17/2007 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A04     7/17/2007 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A03     5/24/2007 WINDOWS 2000
WINDOWS 2000
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A03     5/24/2007 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A03     5/24/2007 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.0/T3.0, A01     5/7/2007 RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.0/T3.0, A01     5/7/2007 RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.0/T3.0, A00     4/11/2007 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.0/T3.0, A00     4/11/2007 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.04, A02     4/11/2007 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.04, A02     4/11/2007 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.04, A02     4/11/2007 WINDOWS 2000
WINDOWS 2000
 
Broadcom NetXtreme II Family of Adapters, v.2.6, A03     12/21/2006 WINDOWS 2000#WINDOWS POWERED
Broadcom NetXtreme II Family of Adapters, v.2.6, A03     12/21/2006 WINDOWS SERVER 2003
Broadcom NetXtreme II Family of Adapters, v.2.6, A03     12/21/2006 WINDOWS SERVER 2003 X64
Broadcom NetXtreme II Family of Adapters, v.2.6, A02     10/23/2006 WINDOWS 2000#WINDOWS POWERED
Broadcom NetXtreme II Family of Adapters, v.2.6, A02     10/23/2006 WINDOWS SERVER 2003 X64
Broadcom NetXtreme II Family of Adapters, v.2.6, A02     10/23/2006 WINDOWS SERVER 2003
Intel PRO Gigabit Adapters, v.8.2, A01     6/9/2006 RED HAT ENTERPRISE LINUX 3
Intel PRO Gigabit Adapters, v.8.2, A01     6/9/2006 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
Intel PRO Gigabit Adapters, v.8.2, A01     6/9/2006 RED HAT ENTERPRISE LINUX 3
Intel PRO Fast Ethernet Adapters, v.8.0.17.0, A00-8.2     6/9/2006 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Intel PRO Gigabit Adapters, v.8.2, A00     6/9/2006 RED HAT ENTERPRISE LINUX 4
Intel PRO Gigabit Adapters, v.8.2, A01     6/9/2006 NETWARE
Intel PRO Gigabit Adapters, v.8.2, A00     6/9/2006 RED HAT ENTERPRISE LINUX 4
Intel PRO Gigabit Adapters, v.8.2, A01     6/9/2006 RED HAT ENTERPRISE LINUX 2.1
Intel PRO Gigabit Adapters, v.8.4.21.0, A00-8.2     6/9/2006 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Intel PRO Gigabit Adapters, v.8.4.21.0, A00-8.2     6/9/2006 WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
 
Broadcom NetXtreme Family of Adapters, v.8.48.0.0, A00-8.3     6/7/2006 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme II Family of Adapters, v.2.6, A00     6/7/2006 NETWARE
Broadcom NetXtreme II Family of Adapters, v.2.6, A00     6/7/2006 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9
Broadcom NetXtreme II Family of Adapters, v.2.6, A00     6/7/2006 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, v.8.3, A00     6/7/2006 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, v.8.3, A00     6/7/2006 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, v.8.3, A00     6/7/2006 NETWARE
Broadcom NetXtreme Family of Adapters, v.8.48.0.0, A00-8.3     6/7/2006 WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
 
Broadcom NetXtreme Family of Adapters, v.8.48.0.0, A00-8.3     6/7/2006 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Broadcom NetXtreme II Family of Adapters, v.2.6, A01     6/7/2006 WINDOWS SERVER 2003
Broadcom NetXtreme II Family of Adapters, v.2.6, A01     6/7/2006 WINDOWS SERVER 2003 X64
Broadcom NetXtreme II Family of Adapters, v.2.6, A01     6/7/2006 WINDOWS 2000#WINDOWS POWERED
Intel PRO Gigabit Adapters, PRO PCI-E Gigabit Family of Adapter, v.9.0, A00     4/17/2006 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9
Intel PRO Gigabit Adapters, PRO PCI-E Gigabit Family of Adapter, v.9.0, A00     4/17/2006 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9
Broadcom NetXtreme Family of Adapters, v.7.107.0.0, A00-7.7     6/9/2005 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
 
Intel PRO Gigabit Adapters, v.8.4.21.0, A00-8.2     3/28/2005 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Intel PRO Fast Ethernet Adapters, v.8.0.17.0, A00-8.2     3/28/2005 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Intel PRO Fast Ethernet Adapters, v.8.0.17.0, A00-8.2     3/28/2005 WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
 
Broadcom NetXtreme Family of Adapters, v.7.100, A00-7.7     3/28/2005 WINDOWS 2000
WINDOWS 2000
 
Broadcom NetXtreme Family of Adapters, v.7.100, A00-7.7     3/28/2005 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom NetXtreme Family of Adapters, v.7.7, A00     3/28/2005 NETWARE
Broadcom NetXtreme Family of Adapters, v.7.7, A01     3/28/2005 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
Broadcom NetXtreme Family of Adapters, v.7.7, A01     3/28/2005 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters, v.7.6, A03     12/7/2004 RED HAT ENTERPRISE LINUX 3
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.80, A01-7.6     11/3/2004 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.80, A01-7.6     11/3/2004 WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
 
Intel PRO 100S, PRO Family of Adapters, PRO1000MT Dual Port, PRO1000MT, PRO1000MF, v.7.2, A00     10/8/2004 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
Intel PRO 100S, PRO Family of Adapters, PRO1000MT Dual Port, PRO1000MT, PRO1000MF, v.7.2, A00     10/8/2004 NETWARE
Intel PRO 100S, PRO Family of Adapters, PRO1000MT Dual Port, PRO1000MT, PRO1000MF, v.7.2, A00     10/8/2004 RED HAT ENTERPRISE LINUX 2.1
Intel PRO 100S, PRO Family of Adapters, PRO1000MT Dual Port, PRO1000MT, PRO1000MF, v.7.2, A00     10/8/2004 RED HAT ENTERPRISE LINUX 2.1
Intel PRO 100S, PRO Family of Adapters, PRO1000MT Dual Port, PRO1000MT, PRO1000MF, v.7.2, A00     10/8/2004 RED HAT ENTERPRISE LINUX 2.1
Intel PRO 100S, PRO Family of Adapters, PRO1000MT Dual Port, PRO1000MT, PRO1000MF, v.7.2, A00     10/8/2004 RED HAT ENTERPRISE LINUX 3
Intel PRO 100S, PRO Family of Adapters, PRO1000MT Dual Port, PRO1000MT, PRO1000MF, v.7.2, A00     10/8/2004 RED HAT ENTERPRISE LINUX 3
Intel PRO 100S, PRO Family of Adapters, PRO1000MT Dual Port, PRO1000MT, PRO1000MF, v.7.2, A00     10/8/2004 MS-DOS
Broadcom NetXtreme Family of Adapters, v.3.6, A02     9/27/2004 RED HAT ENTERPRISE LINUX 3
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters, v.7.6, A00     9/24/2004 RED HAT ENTERPRISE LINUX 2.1
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.6, A00     9/24/2004 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.6, A00     9/24/2004 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.6, A00     9/24/2004 WINDOWS 2000#WINDOWS POWERED
WINDOWS 2000#WINDOWS POWERED
 
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.6, A00     9/24/2004 WINDOWS SERVER 2003
WINDOWS SERVER 2003
 

Historical Network Drivers - HTML

Description Importance Version Released Supported OS Download
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01     9/8/2009 MS-DOS#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 11#SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A00     4/10/2009 MS-DOS#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A02     3/31/2009 MS-DOS#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 4.7#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02     9/9/2008 MS-DOS#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 4.5#RED HAT ENTERPRISE LINUX 5#RED HAT ENTERPRISE LINUX 5.2#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00     9/2/2008 MS-DOS#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A03     4/23/2008 MS-DOS#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A01     4/23/2008 MS-DOS#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A04     1/22/2008 MS-DOS#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.0/T3.0, A00     4/11/2007 MS-DOS#NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Broadcom NetXtreme II Family of Adapters, v.2.6, A00     6/7/2006 MS-DOS#NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Broadcom NetXtreme Family of Adapters, v.8.3, A00     6/7/2006 MS-DOS#NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Broadcom NetXtreme Family of Adapters, v.7.7, A00     7/11/2005 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Intel PRO Gigabit Adapters, v.8.2, A00     6/16/2005 MS-DOS#NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#WINDOWS 2000#WINDOWS SERVER 2003
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.6, A05     11/1/2004 MS-DOS#NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.6, A04     9/30/2004 MS-DOS#NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003

Historical Network Drivers - Utility

Description Importance Version Released Supported OS Download
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00     12/15/2009 NOT APPLICABLE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01     9/8/2009 NOT APPLICABLE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A00     4/10/2009 NOT APPLICABLE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A02     3/30/2009 NOT APPLICABLE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02     10/7/2008 NOT APPLICABLE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00     10/7/2008 WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00     8/27/2008 NOT APPLICABLE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A03     4/23/2008 MS-DOS
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A00     4/23/2008 NOT APPLICABLE
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.0/T3.0, A00     4/11/2007 MS-DOS
Intel PRO Gigabit Adapters, v.8.2, A00     6/9/2006 MS-DOS
Broadcom NetXtreme II Family of Adapters, v.2.6, A00     6/7/2006 MS-DOS
Broadcom NetXtreme Family of Adapters, v.8.3, A00     6/7/2006 MS-DOS
Intel PRO Gigabit Adapters, PRO PCI-E Gigabit Family of Adapter, v.9.0, A00     4/17/2006 NOT APPLICABLE
Broadcom NetXtreme Family of Adapters, v.7.7, A00     7/11/2005 MS-DOS
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.6, A03     11/12/2004 MS-DOS
Broadcom Gigabit 5700, BCM95703, BCM95703s, BCM95701, NetXtreme Family of Adapters , v.7.6, A01     9/24/2004 MS-DOS

 

 

Historical Rack Solutions - Application

Description Importance Version Released Supported OS Download
Dell Rack KVM 2161DS Digital Switch Version 2, Rack KVM 4161DS Digital Switch, v.2.0, A00-00     3/9/2006 RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS XP

Historical Rack Solutions - Firmware

Description Importance Version Released Supported OS Download
Dell Rack KVM 2161DS Digital Switch Version 2, Rack KVM 4161DS Digital Switch, v.1.0.13.1, A00-00     3/9/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS SERVER 2003

Historical Rack Solutions - Utility

Description Importance Version Released Supported OS Download
Dell Rack KVM 2161DS Digital Switch Version 2, Rack KVM 4161DS Digital Switch, v.1.0, A00     5/7/2008 WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64

 

 

Historical Removable Media Storage Devices - Firmware

Description Importance Version Released Supported OS Download
TEAC CD-224E-N slim CDROM ULD, v.3.AC, A01     4/5/2007 NETWARE#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
HLDS GCC-4244N 24x slim combo, v.B104, A03     1/8/2007 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
HLDS GCC-4244N 24x slim combo, v.B103, A02     6/2/2006 WINDOWS 2000#WINDOWS VISTA 32-BIT#WINDOWS VISTA 64-BIT#WINDOWS XP

Historical Removable Media Storage Devices - Utility

Description Importance Version Released Supported OS Download
M-Systems HS 64M / 128M Memory Key, v.1.1.1.7, A01     12/1/2004 WINDOWS 2000#WINDOWS SERVER 2003

 

 

Historical SAS RAID devices - Driver

Description Importance Version Released Supported OS Download
Dell PERC 5/E Adapter, PERC 5/i Integrated, PERC 5/i Adapter, v.00.00.02.05, A02     6/7/2006 SUSE LINUX ES 9
SUSE LINUX ES 9
 
Dell PERC 5/E Adapter, PERC 5/i Integrated, PERC 5/i Adapter, v.1.18.0.32, A02     6/7/2006 WINDOWS 2000#WINDOWS SERVER 2003
WINDOWS 2000#WINDOWS SERVER 2003
WINDOWS 2000#WINDOWS SERVER 2003
  
Dell PERC 5/E Adapter, PERC 5/i Integrated, PERC 5/i Adapter, v.1.18.0.64, A02     6/7/2006 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
  
Dell PERC 5/E Adapter, PERC 5/i Integrated, PERC 5/i Adapter, v.1.17.0.64, A01     4/21/2006 WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
WINDOWS SERVER 2003 X64
  
Dell PERC 5/E Adapter, PERC 5/i Integrated, PERC 5/i Adapter, v.1.17.0.32, A01     4/21/2006 WINDOWS 2000#WINDOWS SERVER 2003
WINDOWS 2000#WINDOWS SERVER 2003
WINDOWS 2000#WINDOWS SERVER 2003
  

Historical SAS RAID devices - Firmware

Description Importance Version Released Supported OS Download
Dell PERC 5/E Adapter, v.5.0.1-0026, A01     4/21/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
     

 

 

Historical SCSI Drives - Utility

Description Importance Version Released Supported OS Download
Dell SCSI Hard Drive Firmware Utility, A09     9/4/2008 NOT APPLICABLE
NOT APPLICABLE
 

 

 

Historical SCSI non-RAID Controllers - BIOS

Description Importance Version Released Supported OS Download
Adaptec 39160 SCSI Controller - Firmware, v.BIOS v3.10, A03     10/8/2004 NOT APPLICABLE

Historical SCSI non-RAID Controllers - Driver

Description Importance Version Released Supported OS Download
Dell Backplane, A05     1/18/2010 WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 R2#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Adaptec 39160 SCSI - Family Manager Set, v.6.4.630.101, A18     7/17/2007 WINDOWS 2000#WINDOWS SERVER 2003
WINDOWS 2000#WINDOWS SERVER 2003
 
Adaptec 39160 SCSI - Family Manager Set, v.6.4.630.100, A16     9/12/2006 WINDOWS 2000
Adaptec 39160 SCSI - Family Manager Set, v.v16.21m/v.8.0, A10     10/8/2004 NETWARE
Adaptec 39160 SCSI - Family Manager Set, v.v16.21m, A11     8/10/2004 NETWARE
Adaptec 39160 SCSI - Family Manager Set, v.6.1.6300.100, A14     8/10/2004 WINDOWS 2000
Adaptec 39160 SCSI - Family Manager Set, v.6.4.630.100, A01     8/10/2004 WINDOWS SERVER 2003

Historical SCSI non-RAID Controllers - Utility

Description Importance Version Released Supported OS Download
Dell Backplane, A03     8/26/2002 WINDOWS 2000

 

 

Historical SCSI Raid - Application

Description Importance Version Released Supported OS Download
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.5.04, A09     6/7/2005 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
 
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.5.32, A08     10/8/2004 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
 

Historical SCSI Raid - Driver

Description Importance Version Released Supported OS Download
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.7.02f, A12     9/30/2005 NETWARE
NETWARE
 
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.7.02c, A10     6/14/2005 NETWARE
NETWARE
 
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, CERC ATA 100, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.6.41.2.32, A04     10/8/2004 WINDOWS SERVER 2003
WINDOWS SERVER 2003
WINDOWS SERVER 2003
 
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.2.10.7, A10     10/8/2004 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3
 
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.7.02c, A09     8/10/2004 NETWARE
NETWARE
 
LSI Logic (formerly AMI) PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.7.01y, A08     8/9/2004 NETWARE
NETWARE
 

Historical SCSI Raid - Firmware

Description Importance Version Released Supported OS Download
LSI Logic PERC 4/SC, PERC 4/DC, v.352D, A22     7/17/2007 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4e/Si, v.522A, A15     9/11/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4/SC, PERC 4/DC, v.352B, A20     9/11/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4e/Si, v.521X, A12     3/28/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4/SC, PERC 4/DC, v.351X, A16     3/28/2006 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4e/Si, v.521S, A05     10/17/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4/SC, PERC 4/DC, v.351S, A09     10/17/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4e/Si, v.521S, A04     6/7/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
LSI Logic PERC 4/SC, PERC 4/DC, v.351S, A08     6/7/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
LSI Logic PERC 4e/Si, v.516A, A01     3/2/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4e/DC, v.513T, A00     10/15/2004 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4/SC, PERC 4/DC, v.350O, A05     10/8/2004 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    
LSI Logic PERC 4e/Si, v.513O, A00     9/17/2004 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
    

Historical SCSI Raid - Utility

Description Importance Version Released Supported OS Download
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.1.03, A02     6/7/2005 WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.1.03, A02     6/7/2005 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4
 

Historical SCSI Raid - XML File

Description Importance Version Released Supported OS Download
Microsoft Storport Version (SAS Non-RAID), Storport Version (SAS RAID), Storport Version (Serial ATA), Storport Version (SCSI RAID), Storport Version (SCSI non-RAID), v.NA, A00     4/21/2009 WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86

 

 

Historical Storage Software - Firmware

Description Importance Version Released Supported OS Download
Dell PowerVault 220S/221S SES Firmware, v.E.18, A07     10/12/2005 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
   
Dell PowerVault 220S/221S SES Firmware, v.E.17, A06     3/29/2004 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
  

 

 

Historical System and Configuration Utilities - Patch/Upgrade

Description Importance Version Released Supported OS Download
Microsoft QFE/GDR/Hotfix, v.QFE907892.BIOSLOCK, A01     11/17/2005 WINDOWS SERVER 2003 X64

 

 

Historical Systems Management - Bundle (SDK only)

Description Importance Version Released Supported OS Download
Dell System Bundle, v.4.2, A00     1/12/2005 WINDOWS SERVER 2003

Historical Systems Management - Utility

Description Importance Version Released Supported OS Download
Dell OpenManage Deployment Toolkit, A01     8/11/2004 MS-DOS

 

 

Historical Tape Devices - Diagnostics Utility

Description Importance Version Released Supported OS Download
Dell PowerVault 110T SDLT320, PowerVault 110T DLT VS160, Powervault 100T DAT72, PowerVault 110T LTO-2-L (Certance), PowerVault 110T LTO-2-L (Tandberg), PowerVault LTO3-060 (IBM), PowerVault LTO3-060 (Tandberg), PowerVault LTO4-120 (IBM), PowerVault LTO4-120HH (IBM), PowerVault LTO3-060 (Quantum), PowerVault LTO3-060 SAS (Quantum), PowerVault LTO4-120 (Quantum), A02     5/20/2010 WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
Dell PowerVault 110T SDLT320, PowerVault 110T DLT VS160, Powervault 100T DAT72, PowerVault 110T LTO-2-L (Certance), PowerVault 110T LTO-2-L (Tandberg), PowerVault LTO3-060 (IBM), PowerVault LTO3-060 (Tandberg), PowerVault LTO4-120 (IBM), PowerVault LTO4-120HH (IBM), PowerVault LTO3-060 (Quantum), PowerVault LTO3-060 SAS (Quantum), PowerVault LTO4-120 (Quantum), A01     6/11/2009 WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86
Dell PowerVault 110T SDLT320, PowerVault 110T DLT VS160, Powervault 100T DAT72, PowerVault 110T LTO-2-L (Certance), PowerVault 110T LTO-2-L (Tandberg), PowerVault LTO3-060 (IBM), PowerVault LTO3-060 (Tandberg), PowerVault LTO4-120 (IBM), PowerVault LTO4-120HH (IBM), PowerVault LTO3-060 (Quantum), PowerVault LTO3-060 SAS (Quantum), PowerVault LTO4-120 (Quantum), A00     11/3/2008 WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X86

Historical Tape Devices - Driver

Description Importance Version Released Supported OS Download
Dell PowerVault LTO4-120 (Quantum), v.3.4, A01     7/16/2008 WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.3.4, A00     5/30/2008 WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
Dell PowerVault 110T LTO-2-L (Certance), v.3.1.2.0, A01     8/14/2007 WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell PowerVault 132T Tape Library, v.Updated Library Driver for Win2000, A05     8/15/2005 WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell PowerVault 110T LTO2, v.6.0.7.13, A03     6/29/2005 WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell PowerVault 110T LTO2, v.6.0.6.8, A02     6/9/2005 WINDOWS SERVER 2003 X64
Dell Powervault 100T DAT72, v.1.11.0.0, A02     6/9/2005 WINDOWS SERVER 2003 X64
Dell PowerVault 110T DLT VS160, Powervault 112T, v.3.0.1.0, A02     6/9/2005 WINDOWS SERVER 2003 X64
Dell PowerVault 110T SDLT, PowerVault 110T SDLT320, v.3.0.1.0, A03     6/9/2005 WINDOWS SERVER 2003 X64
Dell PowerVault 110T LTO-2-L (Certance), v.1.9.0.0, A00     6/7/2005 WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell Powervault 122T SDLT320 Autoloader, v.2.4, A00     12/10/2003 WINDOWS SERVER 2003
Dell PowerVault 110T SDLT320, v.1.7, A00     12/20/2002 WINDOWS 2000

Historical Tape Devices - Firmware

Description Importance Version Released Supported OS Download
Dell PowerVault LTO4-120 (IBM), v.B710, A12     7/27/2011 RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault LTO4-120HH (IBM), v.B6W1/B711, A08     7/27/2011 NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 100T DAT72, v.A16K, A14     5/17/2011 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault LTO4-120HH (IBM), v.B171/A23E, A07     3/23/2011 NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault LTO4-120 (IBM), v.A23D, A11     3/21/2011 RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
 
Dell PowerVault LTO4-120HH (IBM), v.A9Q2/A23E, A06     3/21/2011 NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault LTO4-120HH (IBM), v.A9Q2/A233, A05     12/1/2010 NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.2183, A05     1/6/2010 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault LTO4-120HH (IBM), v.97F1, A04     1/6/2010 NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault LTO4-120 (IBM), v.97F0, A10     1/6/2010 RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 114T Enclosure, PowerVault LTO4-120 (Quantum), v.2210, A05     1/6/2010 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.2183, A04     8/26/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 114T Enclosure, PowerVault LTO4-120 (Quantum), v.2210, A04     8/26/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault 110T SDLT320, v.6262, A18     5/29/2009 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell Powervault 122T SDLT320 Autoloader, v.J12R-6262, A05     5/29/2009 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 132T Tape Library, v.All 132T updates, A13     5/29/2009 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell Powervault 100T DAT72, v.A16J, A13     4/18/2009 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.2182, A03     4/10/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault LTO3-060 (Quantum), v.2181, A02     4/10/2009 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault 132T Tape Library, v.All 132T updates, A12     1/9/2009 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell PowerVault 110T LTO-2-L (Certance), v.1914, A18     12/17/2008 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T DLT VS160, v.3200, A15     12/17/2008 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T SDLT320, v.5D5D, A17     12/17/2008 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 100T DDS4, v.912L, A19     12/17/2008 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault LTO4-120 (Quantum), v.2170, A03     12/12/2008 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 100T DAT72, v.A16E, A12     10/31/2008 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault LTO4-120 (Quantum), v.2143, A02     7/16/2008 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 114T Enclosure, PowerVault LTO4-120 (Quantum), v.2143, A01     7/7/2008 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.2076, A01     5/30/2008 RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#SUSE LINUX ES 10 #SUSE LINUX ES 9#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64#WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
  
Dell PowerVault 110T LTO-2-L (Certance), v.1914, A17     8/15/2007 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell Powervault 100T DAT72, v.A16E, A11     8/15/2007 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 100T DDS4, v.912L, A18     8/15/2007 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO, v.1614, A12     8/15/2007 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T SDLT320, v.5D5D, A16     8/15/2007 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T DLT VS160, v.3200, A14     8/15/2007 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO2, v.67U1, A06     4/12/2007 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO2, v.67U1, A07     4/10/2007 NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
NOT APPLICABLE
  
Dell PowerVault 132T Tape Library, v.All 132T updates, A11     1/4/2007 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell PowerVault 110T LTO-2-L (Certance), v.1914, A16     12/18/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T DLT VS160, v.3200, A13     11/20/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell Powervault 100T DAT72, v.A16E, A10     9/19/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO-2-L (Certance), v.1862, A13     9/19/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T DLT VS160, v.2C00, A12     9/19/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 100T DDS4, v.912L, A17     9/15/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO, v.1614, A11     9/15/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T SDLT320, v.5D5D, A15     9/15/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO2, v.53Y3, A05     9/14/2006 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 132T Tape Library, v.310D.GY004, A10     6/20/2006 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell PowerVault 110T LTO-2-L (Certance), v.1862, A12     6/19/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell Powervault 100T DAT72, v.A16E, A09     6/7/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 100T DDS4, v.912L, A16     6/7/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO-2-L (Certance), v.1785, A11     6/7/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T SDLT320, v.5D5D, A14     6/7/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T DLT VS160, v.2C00, A11     6/7/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO, v.1614, A10     6/7/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
  
Dell PowerVault 110T LTO2, v.53Y3, A04     4/17/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 110T SDLT320, v.5D5D, A08     4/10/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 132T Tape Library, v.all PV132T firmware, A09     3/7/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell Powervault 122T SDLT320 Autoloader, v.J12R-5D5D, A04     3/7/2006 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 110T LTO-2-L (Certance), v.1785, A05     11/22/2005 NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell Powervault 100T DAT72, v.A16E, A03     11/16/2005 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 110T DLT VS160, v.2C00, A04     11/16/2005 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 132T Tape Library, v.LTO1-4561, A08     10/19/2005 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell Powervault 122T SDLT320 Autoloader, v.J12R-5252, A03     10/7/2005 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 122T DLT VS80 Autoloader, v.5538, A03     10/7/2005 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 100T DDS4, v.911D, A08     10/7/2005 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 110T LTO, v.1614, A03     10/7/2005 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 110T DLT VS160, v.2500, A03     10/7/2005 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 122T DLT VS80 Autoloader, v.5538, A02     9/30/2005 NETWARE#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 100T DDS4, v.911D, A07     9/30/2005 NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 110T LTO, v.1614, A02     9/30/2005 NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell Powervault 122T SDLT320 Autoloader, v.J12R-5252, A02     9/30/2005 NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
NETWARE#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#SUSE LINUX ES 9#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
 
Dell PowerVault 132T Tape Library, v.LTO3, A07     8/18/2005 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell PowerVault 110T LTO2, v.53Y3, A03     6/22/2005 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
Dell PowerVault 110T LTO2, v.3AYC, A02     12/3/2004 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003
Dell PowerVault 110T SDLT, PowerVault 110T SDLT320, v.5252(V82)PVtool1.3.8.0, A06     9/20/2004 WINDOWS 2000#WINDOWS SERVER 2003
Dell PowerVault 110T LTO2, v.3AYC, A02     7/27/2004 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003
Dell PowerVault 110T LTO2, v.3AYC, A02     7/9/2004 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003
Dell PowerVault 110T LTO2, v.3YAC, A02     5/11/2004 NETWARE#RED HAT LINUX 7.3#RED HAT LINUX 8.0#WINDOWS 2000#WINDOWS POWERED#WINDOWS SERVER 2003

Historical Tape Devices - Utility

Description Importance Version Released Supported OS Download
Dell PowerVault 100T DDS4, PowerVault 110T LTO, PowerVault 110T SDLT, PowerVault 110T DLT VS80, PowerVault 110T SDLT320, PowerVault 110T DLT VS160, Powervault 100T DAT72, Powervault 114T Enclosure, PowerVault 110T LTO-2-L (Certance), PowerVault LTO3-060 (Quantum), PowerVault LTO3-060 SAS (Quantum), PowerVault LTO4-120 (Quantum), v.6.2.0.7, A06     5/20/2010 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 10 #SUSE LINUX ES 9
Dell PowerVault 100T DDS4, PowerVault 110T LTO, PowerVault 110T SDLT, PowerVault 110T DLT VS80, PowerVault 110T SDLT320, PowerVault 110T DLT VS160, Powervault 100T DAT72, Powervault 114T Enclosure, PowerVault 110T LTO-2-L (Certance), PowerVault LTO3-060 (Quantum), PowerVault LTO3-060 SAS (Quantum), PowerVault LTO4-120 (Quantum), v.6.1.2, A05     6/11/2009 RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4#RED HAT ENTERPRISE LINUX 5#RED HAT LINUX 6.1#RED HAT LINUX 6.2#RED HAT LINUX 7.0#RED HAT LINUX 7.1#RED HAT LINUX 7.2#RED HAT LINUX 7.3#RED HAT LINUX 8.0#RED HAT LINUX 9.0#SUSE LINUX ES 10 #SUSE LINUX ES 9

 

 

Historical Tape Software - Application

Description Importance Version Released Supported OS Download
Yosemite TapeWare, v.7.0_SP5C, A00     8/13/2004 NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003
NETWARE#RED HAT ENTERPRISE LINUX 2.1#RED HAT ENTERPRISE LINUX 3#WINDOWS 2000#WINDOWS NT 4.0#WINDOWS POWERED#WINDOWS SERVER 2003
 

 

 

Historical Video Drivers - Driver

Description Importance Version Released Supported OS Download
ATI Radeon 7000M, v.8.24.50.3-080121a-058688C, A00     2/27/2008 WINDOWS SERVER 2008 X64#WINDOWS SERVER 2008 X86
ATI Radeon 7000M, v.8.19.4 , A04     4/10/2007 WINDOWS 2000#WINDOWS SERVER 2003#WINDOWS SERVER 2003 X64
ATI Radeon 7000M, v.xorg-x11-driver-video-6[1].9.0-46.18.x86_64 , A00     4/10/2007 SUSE LINUX ES 10 
ATI Radeon 7000M, v.radeon7000_RH_A10, A10     4/17/2006 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4
ATI Radeon 7000M, v.radeon7000_RH_A09, A09     10/17/2005 RED HAT ENTERPRISE LINUX 3#RED HAT ENTERPRISE LINUX 4
ATI Radeon 7000M, v.(X64) 8.12-050317m-022598C, A01     6/10/2005 WINDOWS SERVER 2003 X64
ATI Radeon 7000M, v.0.5-1, A02-00     3/29/2005 RED HAT ENTERPRISE LINUX 2.1
ATI Radeon 7000M, v.0.5-1, A02-00     3/29/2005 RED HAT ENTERPRISE LINUX 3
ATI Radeon 7000M, v.0.5-1, A00-00     3/29/2005 RED HAT ENTERPRISE LINUX 3
ATI Radeon 7000M, v.8.08-041111a-020816C-Dell-WHQL, A02     3/29/2005 WINDOWS 2000#WINDOWS SERVER 2003
ATI Radeon 7000M, v.7.98-040120a-015445C-Dell.2-WHQL, A00-00     8/9/2004 WINDOWS 2000
ATI Radeon 7000M, v.7.98-040120a-015445C.2-WHQL, A00-00     8/9/2004 WINDOWS SERVER 2003
ATI Radeon 7000M, v.0.4-1, A01-00     8/9/2004 RED HAT ENTERPRISE LINUX 2.1
ATI Radeon 7000M, v.0.4-1, A01-00     8/9/2004 RED HAT ENTERPRISE LINUX 3

 

 

IDE/EIDE - Driver

Description Importance Version Released Supported OS Download
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, CERC ATA 100, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.5.48.0.0, A04
Dell PowerEdge RAID Controller 4e/Di, 4e/Si, 4e/DC, 4/DC, 4/SC, 3/QC, 3/DC, 3/DCL, 3/SC, PERC 4/Di, and CERC ATA100/4CH Device Driver for Windows 2000. Version: 5.48
Recommended 5.48.0.0 8/8/2007 Windows Powered
Windows 2000
  

 

 

Network - Driver

Description Importance Version Released Supported OS Download
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 14.1.5 12/15/2009 Windows Server 2008 x64
Windows Server 2003 x64
Windows Server 2008 R2
  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI Offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 14.1.5 12/15/2009 Windows Server 2008 x86
Windows Server 2003
  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00
Broadcom NetXtreme I and NetXtreme II Netware Drivers to support adapters based on 5721, 5722, 5708, 5709, 57710 and 57711
Optional 14.1.5 12/15/2009 Netware
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00
Linux source code packages, family version 14.1.5 to support Broadcom NetXtreme I and NetXtreme II based adapters.
Recommended 14.1.5 12/15/2009 SuSE Linux ES 10 SP2 x86_64
Red Hat Enterprise Linux 4.7
SuSE Linux ES 9 SP4 x86_64
Red Hat Enterprise Linux 4
SuSE Linux ES 10
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 3
SuSE Linux ES 11
SuSE Linux ES 9
Red Hat Enterprise Linux 5.2
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00
Linux driver update to 14.1.5 for NetXtreme I and NetXtreme II devices
Recommended 14.1.5 12/15/2009 Red Hat Enterprise Linux 5.2
SuSE Linux ES 10 SP2 x86_64
SuSE Linux ES 10
Red Hat Enterprise Linux 5
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00
Linux Red Hat 4, SLES 9/11 Software update family version 14.1.5 for NetXtreme I and NetXtreme II adapters
Recommended 14.1.5 12/15/2009 Red Hat Enterprise Linux 4
SuSE Linux ES 9
SuSE Linux ES 11
Red Hat Enterprise Linux 4.5
SuSE Linux ES 9 SP4 x86_64
Red Hat Enterprise Linux 4.7
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.1, A03
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 14.1.1 9/29/2009 Windows Server 2008 x64
Windows Server 2003 x64
Windows Server 2008 R2
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.1, A03
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI Offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 14.1.1 9/29/2009 Windows Server 2008 x86
Windows Server 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A02
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 14.1.0 9/11/2009 Windows Server 2003 x64
Windows Server 2008 x64
Windows Server 2008 R2
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01
Linux Red Hat 4, SLES 9/11 Software update family version 14.1.0 for NetXtreme I and NetXtreme II adapters
Recommended 14.1.0 9/8/2009 Red Hat Enterprise Linux 4.5
Red Hat Enterprise Linux 4
SuSE Linux ES 11
SuSE Linux ES 9
Red Hat Enterprise Linux 4.7
SuSE Linux ES 9 SP4 x86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01
Linux driver update to 14.1.0 for NetXtreme I and NetXtreme II devices
Recommended 14.1.0 9/8/2009 Red Hat Enterprise Linux 5
SuSE Linux ES 10
Red Hat Enterprise Linux 5.2
SuSE Linux ES 10 SP2 x86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01
Linux source code packages, family version 14.0.1 to support Broadcom NetXtreme I and NetXtreme II based adapters.
Recommended 14.1.0 9/8/2009 SuSE Linux ES 11
Red Hat Enterprise Linux 4.7
Red Hat Enterprise Linux 4
SuSE Linux ES 10 SP2 x86_64
SuSE Linux ES 10
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 5
SuSE Linux ES 9 SP4 x86_64
Red Hat Enterprise Linux 5.2
SuSE Linux ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01
Broadcom NetXtreme I and NetXtreme II Netware Drivers to support adapters based on 5721, 5722, 5708, 5709, 57710 and 57711
Recommended 14.1.0 9/8/2009 Netware
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI Offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 14.1.0 9/8/2009 Windows Server 2008 x86
Windows Server 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.1, A00
Linux source code packages for Broadcom NetXtreme I and NetXtreme II Devices.
Recommended 12.8.1 7/7/2009 Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 4.7
SuSE Linux ES 10
SuSE Linux ES 9 SP4 x86_64
SuSE Linux ES 10 SP2 x86_64
Red Hat Enterprise Linux 5.2
SuSE Linux ES 11
Red Hat Enterprise Linux 5
SuSE Linux ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.1, A00
Linux driver update to 12.6 for NetXtreme I and NetXtreme II devices
Recommended 12.8.1 7/7/2009 Red Hat Enterprise Linux 5
SuSE Linux ES 10
SuSE Linux ES 10 SP2 x86_64
Red Hat Enterprise Linux 5.2
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.1, A00
Linux driver update to 12.8.1 for NetXtreme I and NetXtreme II devices
Recommended 12.8.1 7/7/2009 Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 4.7
SuSE Linux ES 9
SuSE Linux ES 11
Red Hat Enterprise Linux 4.5
SuSE Linux ES 9 SP4 x86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 12.8.0 4/10/2009 Windows Server 2008 x64
Windows Server 2003 x64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI Offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 12.8.0 4/10/2009 Windows Server 2008 x86
Windows Server 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01
Linux source code packages for 12.8.0 relases for NetXtreme I and NetXtreme II devices
Recommended 12.8.0 4/10/2009 SuSE Linux ES 9
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 5
SuSE Linux ES 9 SP4 x86_64
Red Hat Enterprise Linux 4.7
Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 5.2
SuSE Linux ES 10 SP2 x86_64
SuSE Linux ES 10
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01
Linux driver update to 12.6 for NetXtreme I and NetXtreme II devices
Recommended 12.8.0 4/10/2009 Red Hat Enterprise Linux 5.2
SuSE Linux ES 10
Red Hat Enterprise Linux 5
SuSE Linux ES 10 SP2 x86_64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A01
Linux driver update to 12.6 for NetXtreme I and NetXtreme II devices
Recommended 12.8.0 4/10/2009 Red Hat Enterprise Linux 4.5
Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 4.7
SuSE Linux ES 9 SP4 x86_64
SuSE Linux ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A00
Broadcom NetXtreme I and NetXtreme II Netware Drivers, family versions 12.8.0.
Recommended 12.8.0 4/10/2009 Netware
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A05
Linux source code packages for 12.6.0 relases for NetXtreme I and NetXtreme II devices
Recommended 12.6.0 3/31/2009 Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4.7
SuSE Linux ES 10 SP2 x86_64
SuSE Linux ES 9 SP4 x86_64
Red Hat Enterprise Linux 5.2
SuSE Linux ES 9
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 4
SuSE Linux ES 10
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A03
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Urgent 12.4.0 10/7/2008 Windows Server 2003 x64
Windows Server 2008 x64
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02
Broadcom NetXtreme I and NetXtreme II Netware Drivers, family versions 12.4.0. This release will support 5709 and 57710 based adapters
Recommended 12.4.0 10/7/2008 Netware
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02
Linux driver update to 12.4 for NetXtreme I and NetXtreme II devices
Recommended 12.4.0 10/7/2008 Red Hat Enterprise Linux 4.5
Red Hat Enterprise Linux 4
SuSE Linux ES 9 SP4 x86_64
SuSE Linux ES 9
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02
Linux driver update to 12.4 for NetXtreme I and NetXtreme II devices
Recommended 12.4.0 10/7/2008 SuSE Linux ES 10
Red Hat Enterprise Linux 5
SuSE Linux ES 10 SP2 x86_64
Red Hat Enterprise Linux 5.2
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02
Linux source code packages for 12.4.0 relases for NetXtreme I and NetXtreme II devices
Recommended 12.4.0 10/7/2008 SuSE Linux ES 10
SuSE Linux ES 10 SP2 x86_64
Red Hat Enterprise Linux 4
SuSE Linux ES 9
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 3
SuSE Linux ES 9 SP4 x86_64
Red Hat Enterprise Linux 5.2
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02
Windows Server 2003 and 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) and iSCSI Offload when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft
Recommended 12.4.0 10/7/2008 Windows Server 2008 x86
Windows Server 2003
 
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A02
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Recommended 12.0 5/6/2008 Windows Server 2003 x64  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A02
Windows Server 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices TOE (TCP/IP Offload Engine) is currently turned off in this release due to problems in the OS.
Recommended 12.0 5/6/2008 Windows Server 2008 x86  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A02
Windows Server 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices TOE (TCP/IP Offload Engine) is currently turned off in this release due to problems in the OS
Recommended 12.0 5/6/2008 Windows Server 2008 x64  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A02
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Recommended 12.0 5/6/2008 Windows Server 2003  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.51.01, A04
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Recommended 10.51.01 5/5/2008 Windows Server 2003  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.51.01, A04
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Recommended 10.51.01 5/5/2008 Windows Server 2003 x64  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A00
Broadcom NetXtreme I and NetXtreme II Netware Drivers, family versions 11.0 and 4.1
Recommended 11.0/T4.1 4/11/2008 Netware
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A00
Linux source code packages for 11.0 and T4.1 relases for NetXtreme I and NetXtreme II devices
Recommended 11.0/T4.1 4/11/2008 Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 3
SuSE Linux ES 9
SuSE Linux ES 10
Red Hat Enterprise Linux 4
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A00
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Recommended 12.0 3/18/2008 Windows Server 2003  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A00
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Recommended 12.0 3/18/2008 Windows Server 2003 x64  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A00
Linux driver update to 11.0 and T4.1 for NetXtreme I and NetXtreme II devices RHEL4.5, x86 RHEL4.5, x64 RHEL5.0, x86 RHEL5.0, x64 SLES9.3, x64 SLES10.0, x64
Recommended 11.0/T4.1 3/18/2008 SuSE Linux ES 9
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4
SuSE Linux ES 10
Red Hat Enterprise Linux 3
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A00
Windows Server 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices TOE (TCP/IP Offload Engine) is currently turned off in this release due to problems in the OS
Recommended 12.0 3/3/2008 Windows Server 2008 x64  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.0, A00
Windows Server 2008 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices TOE (TCP/IP Offload Engine) is currently turned off in this release due to problems in the OS.
Recommended 12.0 3/3/2008 Windows Server 2008 x86  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A04
Linux DKMS RPMS for the NetXtreme I and NetXtreme II network devices
Recommended 10.5/T3.5 11/20/2007 SuSE Linux ES 10
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4
SuSE Linux ES 9
Red Hat Enterprise Linux 3
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A04
Linux source code packages for 10.5 and T3.5 relases for NetXtreme I and NetXtreme II devices
Recommended 10.5/T3.5 11/20/2007 Red Hat Enterprise Linux 3
SuSE Linux ES 9
Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 5
SuSE Linux ES 10
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A03
Broadcom NetXtreme I and NetXtreme II Netware Drivers, family versions 10.5 and 3.5.
Recommended 10.5/T3.5 11/20/2007 Netware
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.51.01, A03
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Recommended 10.51.01 11/20/2007 Windows Server 2003 x64  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.51.01, A03
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Recommended 10.51.01 11/20/2007 Windows Server 2003  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.19.01, A05
Windows 2000 Server driver files and Management Applications for Broadcom NetXtreme I and NeXtreme II devices.
Optional 10.19.01 8/29/2007 Windows 2000  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.19.01, A05
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Optional 10.19.01 8/29/2007 Windows Server 2003  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.19.01, A05
Windows Server 2003 (64bit) driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003
Optional 10.19.01 8/29/2007 Windows Server 2003 x64  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A04
Windows 2000 Server driver files and Management Applications for Broadcom NetXtreme I and NeXtreme II devices.
Optional 10.18.06 7/17/2007 Windows 2000  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A04
Windows Server 2003 driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003 Scalable
Optional 10.18.06 7/17/2007 Windows Server 2003  
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.18.06, A04
Windows Server 2003 (64bit) driver files and Management Applications for Broadcom NetXtreme I and NetXtreme II devices. The Broadcom NetXtreme II devices support TOE (TCP/IP Offload Engine) when installed under Windows Server 2003, with Service Pack 1 or newer and the Microsoft Windows Server 2003
Optional 10.18.06 7/17/2007 Windows Server 2003 x64  

Network - HTML

Description Importance Version Released Supported OS Download
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01
Broadcom NetXtreme User's Manual for family version 14.1.0 . Broadcom Release CD: T5.0.4.1
Optional 14.1.0 9/8/2009 Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4.5
Windows Server 2003 x64
SuSE Linux ES 10
Red Hat Enterprise Linux 4.7
Windows Server 2008 R2
Red Hat Enterprise Linux 4
SuSE Linux ES 9
Red Hat Enterprise Linux 5.2
SuSE Linux ES 11
Red Hat Enterprise Linux 3
Windows Server 2008 x64
Windows Server 2003
MS-DOS
Windows Server 2008 x86
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A00
NetXtreme I and NetXtreme II Users Manuals for the 12.8.0 Family of Drivers Releases for Broadcom network interface devices.
Recommended 12.8.0 4/10/2009 Red Hat Enterprise Linux 3
Windows Server 2008 x64
Windows Server 2008 x86
Red Hat Enterprise Linux 4.7
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4.5
Windows Server 2003 x64
MS-DOS
Windows 2000
Red Hat Enterprise Linux 4
SuSE Linux ES 9
Windows Server 2003
Red Hat Enterprise Linux 5.2
SuSE Linux ES 10
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.6.0, A02
NetXtreme I and NetXtreme II Users Manuals for the 12.6.0 Family of Drivers Releases for Broadcom network interface devices.
Recommended 12.6.0 3/31/2009 Windows Server 2003 x64
Windows Server 2008 x64
Windows Server 2008 x86
SuSE Linux ES 10
Red Hat Enterprise Linux 4.5
Red Hat Enterprise Linux 4
Windows 2000
Red Hat Enterprise Linux 5.2
Windows Server 2003
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 5
SuSE Linux ES 9
Red Hat Enterprise Linux 4.7
MS-DOS
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02
NetXtreme I and NetXtreme II Users Manuals for the 12.4.0 Family of Drivers Releases for Broadcom network interface devices.
Recommended 12.4.0 10/7/2008 Red Hat Enterprise Linux 4.5
Red Hat Enterprise Linux 5
MS-DOS
SuSE Linux ES 10
Windows Server 2008 x86
SuSE Linux ES 9
Red Hat Enterprise Linux 3
Windows Server 2008 x64
Windows 2000
Windows Server 2003 x64
Windows Server 2003
Red Hat Enterprise Linux 5.2
Red Hat Enterprise Linux 4
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A01
NetXtreme I and NetXtreme II Users Manuals for the 11.0 and T4.1 Family of Drivers Releases for Broadcom network interface devices.
Recommended 11.0/T4.1 2/29/2008 SuSE Linux ES 9
Windows Server 2003
Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 3
Windows Server 2003 x64
Windows 2000
Red Hat Enterprise Linux 5
Windows Server 2008 x64
SuSE Linux ES 10
Windows Server 2008 x86
MS-DOS
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A04
NetXtreme I and NetXtreme II Users Manuals for the 10.5 and T3.5 Family of Drivers Releases for Broadcom network interface devices.
Recommended 10.5/T3.5 1/22/2008 SuSE Linux ES 9
SuSE Linux ES 10
Red Hat Enterprise Linux 4
MS-DOS
Red Hat Enterprise Linux 5
Windows 2000
Windows Server 2003 x64
Red Hat Enterprise Linux 3
Windows Server 2003
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A03
NetXtreme I and NetXtreme II Users Manuals for the 10.5 and T3.5 Family of Drivers Releases for Broadcom network interface devices.
Recommended 10.5/T3.5 11/20/2007 Windows Server 2003
Windows Server 2003 x64
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 5
SuSE Linux ES 9
MS-DOS
Red Hat Enterprise Linux 4
Windows 2000
SuSE Linux ES 10

Network - Utility

Description Importance Version Released Supported OS Download
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.5, A00
Broadcom NetXtreme I and NetXtreme II DOS Utilities, for family version 14.1.5
Optional 14.1.5 12/15/2009 OS Independent
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.14.1.0, A01
Broadcom NetXtreme I and NetXtreme II DOS Utilities, for family version 14.1.0
Recommended 14.1.0 9/8/2009 OS Independent
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.8.0, A00
Broadcom NetXtreme I and NetXtreme II DOS Utilities, for family version 12.8
Recommended 12.8.0 4/10/2009 OS Independent
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A02
Broadcom NetXtreme I and NetXtreme II DOS Utilities, for family version 12.4
Recommended 12.4.0 10/7/2008 OS Independent
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.12.4.0, A00
Broadcom NetXtreme I and NetXtreme II Windows 2008 Server Core Utilities, for family version 12.4. This utility is used to manage advance networking features such as teaming, VLAN, device driver information and iSCSI offload of Broadcom BCM5722, BCM5708, BCM5709 and BCM57710 devices on Dell
Optional 12.4.0 10/7/2008 Windows Server 2008 x86
Windows Server 2008 x64
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.11.0/T4.1, A00
Broadcom NetXtreme I and NetXtreme II DOS Utilities, for family version 11.0 and 4.1
Recommended 11.0/T4.1 3/3/2008 OS Independent
Broadcom NetXtreme Family of Adapters, NetXtreme II Family of Adapters, v.10.5/T3.5, A03
Broadcom NetXtreme I and NetXtreme II DOS Utilities, for family version 10.5 and 3.5.
Recommended 10.5/T3.5 11/20/2007 MS-DOS

 

 

Rack Solutions - Utility

Description Importance Version Released Supported OS Download
Dell Rack KVM 2161DS Digital Switch Version 2, Rack KVM 4161DS Digital Switch, v.1.0, A00
Active Directory support for networks utilizing Dell OpenManage for either 32-bit or 64-bit Active Directory. Dell Schema Extensions for Active Directory, as well as an LDIF script in order to extend the schema.
Not Defined 1.0 5/7/2008 Windows Server 2003
Windows Server 2003 x64

 

 

SAS Non-RAID - XML File

Description Importance Version Released Supported OS Download
Microsoft Storport Version (SAS Non-RAID), Storport Version (SAS RAID), Storport Version (Serial ATA), Storport Version (SCSI RAID), Storport Version (SCSI non-RAID), v.NA, A00
This file contains information about the Dell tested and recommended storport versions.
Urgent NA 4/21/2009 Windows Server 2003 x64
Windows Server 2008 x86
Windows Server 2003
Windows Server 2008 x64

 

 

SAS RAID - XML File

Description Importance Version Released Supported OS Download
Microsoft Storport Version (SAS Non-RAID), Storport Version (SAS RAID), Storport Version (Serial ATA), Storport Version (SCSI RAID), Storport Version (SCSI non-RAID), v.NA, A00
This file contains information about the Dell tested and recommended storport versions.
Urgent NA 4/21/2009 Windows Server 2008 x64
Windows Server 2003 x64
Windows Server 2008 x86
Windows Server 2003

 

 

SCSI Drive - Utility

Description Importance Version Released Supported OS Download
Dell SCSI Hard Drive Firmware Utility, A09
This is a full compilation of all drives and drive firmware supported under SCSI releases. A drive listed in the Fixes/Enhancements secton indicates that it is a new addition to this release. For more details about the other firmware included please download the individual readme file.
Recommended A09 9/4/2008 OS Independent  

 

 

SCSI non-RAID - Driver

Description Importance Version Released Supported OS Download
Dell Backplane, A05
This INF file contains support for Dell PowerEdge Servers and PowerVault storage products. This INF file will prevent the yellow warning from displaying in the Windows Device Manager.
Recommended A05 1/18/2010 Windows Server 2008 x64
Windows Server 2003
Windows Server 2003 x64
Windows Server 2008 R2
Windows Server 2008 x86
Adaptec 39160 SCSI - Family Manager Set, v.6.4.630.101, A18
Adaptec 39160/29160/7892/7899 SCSI Controller Driver Set for Win2k/XP/Win2k3 Server family.
Recommended 6.4.630.101 7/17/2007 Windows Server 2003
Windows 2000
 

SCSI non-RAID - XML File

Description Importance Version Released Supported OS Download
Microsoft Storport Version (SAS Non-RAID), Storport Version (SAS RAID), Storport Version (Serial ATA), Storport Version (SCSI RAID), Storport Version (SCSI non-RAID), v.NA, A00
This file contains information about the Dell tested and recommended storport versions.
Urgent NA 4/21/2009 Windows Server 2008 x86
Windows Server 2003
Windows Server 2003 x64
Windows Server 2008 x64

 

 

SCSI RAID - Driver

Description Importance Version Released Supported OS Download
LSI Logic PERC3/DCL, PERC3/DC, PERC3/QC, PERC3/SC, PERC 4/Di, CERC ATA 100, PERC 4/SC, PERC 4/DC, PERC 4e/DC, Perc 4e/Di, PERC 4e/Si, v.5.48.0.0, A04
Dell PowerEdge RAID Controller 4e/Di, 4e/Si, 4e/DC, 4/DC, 4/SC, 3/QC, 3/DC, 3/DCL, 3/SC, PERC 4/Di, and CERC ATA100/4CH Device Driver for Windows 2000. Version: 5.48
Recommended 5.48.0.0 8/8/2007 Windows Powered
Windows 2000
  

SCSI RAID - Firmware

Description Importance Version Released Supported OS Download
LSI Logic PERC 4/SC, PERC 4/DC, v.352D, A22
Dell PowerEdge Expandable RAID Controller 4/DC and 4/SC Firmware Update Version: 352D
Urgent 352D 7/18/2007 OS Independent     

SCSI RAID - XML File

Description Importance Version Released Supported OS Download
Microsoft Storport Version (SAS Non-RAID), Storport Version (SAS RAID), Storport Version (Serial ATA), Storport Version (SCSI RAID), Storport Version (SCSI non-RAID), v.NA, A00
This file contains information about the Dell tested and recommended storport versions.
Urgent NA 4/21/2009 Windows Server 2008 x64
Windows Server 2003
Windows Server 2003 x64
Windows Server 2008 x86

 

 

Serial ATA - XML File

Description Importance Version Released Supported OS Download
Microsoft Storport Version (SAS Non-RAID), Storport Version (SAS RAID), Storport Version (Serial ATA), Storport Version (SCSI RAID), Storport Version (SCSI non-RAID), v.NA, A00
This file contains information about the Dell tested and recommended storport versions.
Urgent NA 4/21/2009 Windows Server 2003 x64
Windows Server 2008 x64
Windows Server 2008 x86
Windows Server 2003

 

 

Tape Automation - Firmware

Description Importance Version Released Supported OS Download
Dell PowerVault 132T Tape Library, v.All 132T updates, A13
Firmware for the PowerVault 132T Library, LTO1, LTO2, and LTO3 Tape Drives, SDLT320 Tape Drive, Remote Management Unit, and SNC Module.
Recommended All 132T updates 5/29/2009 Red Hat Enterprise Linux 3
Windows NT 4.0
Red Hat Linux 7.2
Red Hat Linux 6.1
Windows Server 2003 x64
Windows 2000
Red Hat Linux 7.3
Red Hat Linux 7.0
Red Hat Linux 7.1
Red Hat Linux 6.2
Netware
Red Hat Linux 9.0
Red Hat Enterprise Linux 2.1
Red Hat Linux 8.0
Windows Server 2003
Red Hat Enterprise Linux 4
Windows Powered
 
Dell Powervault 122T SDLT320 Autoloader, v.J12R-6262, A05
This release includes the following: new firmware version v6262 (v100) DFU utility v1.3.10 - Firmware flash utility that updates one drive at a time.
Recommended J12R-6262 5/29/2009 Red Hat Linux 6.1
Windows Server 2003 x64
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 2.1
Red Hat Linux 7.0
Netware
Windows NT 4.0
Red Hat Linux 6.2
SuSE Linux ES 9
Windows 2000
Windows Server 2003
Red Hat Enterprise Linux 4
 
Dell PowerVault 132T Tape Library, v.All 132T updates, A12
Firmware for the PowerVault 132T Library, LTO1, LTO2, and LTO3 Tape Drives, SDLT320 Tape Drive, Remote Management Unit, and SNC Module.
Recommended All 132T updates 1/9/2009 Red Hat Linux 8.0
Red Hat Enterprise Linux 2.1
Windows Powered
Red Hat Linux 7.1
Windows NT 4.0
Windows 2000
Red Hat Linux 7.3
Windows Server 2003
Red Hat Linux 9.0
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 4
Red Hat Linux 6.1
Red Hat Linux 7.0
Netware
Red Hat Linux 6.2
Red Hat Linux 7.2
Windows Server 2003 x64

 

 

Tape Drives - Diagnostics Utility

Description Importance Version Released Supported OS Download
Dell PowerVault 110T SDLT320, PowerVault 110T DLT VS160, Powervault 100T DAT72, PowerVault 110T LTO-2-L (Certance), PowerVault 110T LTO-2-L (Tandberg), PowerVault LTO3-060 (IBM), PowerVault LTO3-060 (Tandberg), PowerVault LTO4-120 (IBM), PowerVault LTO4-120HH (IBM), PowerVault LTO3-060 (Quantum), PowerVault LTO3-060 SAS (Quantum), PowerVault LTO4-120 (Quantum), A01
Tape Drive Diagnostics
Optional A01 6/11/2009 Windows Server 2008 x86
Windows 2000
Windows Server 2003

Tape Drives - Driver

Description Importance Version Released Supported OS Download
Dell PowerVault LTO4-120 (Quantum), v.3.4, A01
Initial release of version 3.4 of drivers for Quantum LTO4-120 SAS drive.
Recommended 3.4 7/16/2008 Windows Server 2008 x86
Windows Server 2008 x64
Windows Server 2003
Windows Server 2003 x64
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.3.4, A00
Initial release of version 3.4 of drivers for LTO3-060 SAS drive, with WHQL signatures.
Recommended 3.4 6/16/2008 Windows Server 2003 x64
Windows Server 2008 x86
Windows Server 2003
Windows Server 2008 x64
Dell Powervault 100T DAT72, v.1.11.0.0, A02
Driver for DAT72 TBU Drive.
Optional 1.11.0.0 2/4/2008 Windows Server 2003 x64
Dell PowerVault 110T LTO-2-L (Certance), v.3.1.2.0, A01
This driver is for Windows Server 2000, 2003, and 2003 x64.
Recommended 3.1.2.0 8/14/2007 Windows Server 2003 x64
Windows Powered
Windows 2000
Windows Server 2003

Tape Drives - Firmware

Description Importance Version Released Supported OS Download
Dell PowerVault LTO4-120HH (IBM), v.B6W1/B711, A08
Firmware upgrade for Dell PowerVault LTO4-120-HH (IBM) Tape Drive. This release contains B6W1/B711 drive firmware and ITDT-DCR.
Urgent B6W1/B711 7/27/2011 Red Hat Enterprise Linux 4
Windows Server 2008 x86
SuSE Linux ES 9
SuSE Linux ES 10
Windows Server 2003
Windows Server 2008 x64
Red Hat Enterprise Linux 5
Windows Server 2003 x64
Netware
   
Dell PowerVault LTO4-120 (IBM), v.B710, A12
Firmware upgrade for Dell PowerVault LTO4-120 Tape Drive. This release contains B710 drive firmware and ITDT-DCR (Firmware upgrade utility and diagnostic tool).
Urgent B710 7/27/2011 SuSE Linux ES 10
Windows Server 2008 x86
Windows Server 2008 x64
SuSE Linux ES 9
Windows Server 2003
Windows Server 2003 x64
Red Hat Enterprise Linux 4
   
Dell PowerVault LTO4-120HH (IBM), v.B171/A23E, A07
Firmware upgrade for Dell PowerVault LTO4-120-HH (IBM) Tape Drive. This release contains B171 drive firmware and ITDT-DCR version 2.0.0.010.
Recommended B171/A23E 6/3/2011 Windows Server 2003
SuSE Linux ES 9
Windows Server 2008 x64
Windows Server 2008 x86
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4
Windows Server 2003 x64
SuSE Linux ES 10
Netware
    
Dell Powervault 100T DAT72, v.A16K, A14
This is firmware verison A16k. This release includes the DFU (Dell Firmware Update) Utility which will allow users to update one device at a time as well as the DUP (Dell Update Package) Utility which can be used to update all devices automatically. A14 release includes a high cleaning tension.
Recommended A16K 5/17/2011 SuSE Linux ES 10
Windows Server 2003
SuSE Linux ES 9
Windows Server 2008 x64
Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 3
Windows 2000
Netware
Windows Server 2003 x64
Red Hat Enterprise Linux 5
Windows NT 4.0
Windows Server 2008 x86
Red Hat Enterprise Linux 2.1
Windows Powered
    
Dell PowerVault LTO4-120HH (IBM), v.A9Q2/A23E, A06
Firmware upgrade for Dell PowerVault LTO4-120HH (IBM) Tape Drive which add support for v2 drives. This release contains A9Q2 drive firmware and ITDT-DCR version 1.2.0.005.
Recommended A9Q2/A23E 3/21/2011 Windows Server 2003 x64
Windows Server 2008 x64
SuSE Linux ES 9
Red Hat Enterprise Linux 4
SuSE Linux ES 10
Windows Server 2008 x86
Red Hat Enterprise Linux 5
Windows Server 2003
Netware
    
Dell PowerVault LTO4-120 (IBM), v.A23D, A11
Firmware upgrade for Dell PowerVault LTO4-120 Tape Drive. This release contains A23D drive firmware and ITDT-DCR (Firmware upgrade utility and diagnostic tool).
Recommended A23D 3/21/2011 SuSE Linux ES 10
Windows Server 2008 x64
SuSE Linux ES 9
Red Hat Enterprise Linux 4
Windows Server 2003
Windows Server 2008 x86
Windows Server 2003 x64
  
Dell PowerVault LTO4-120HH (IBM), v.A9Q2/A233, A05
Firmware upgrade for Dell PowerVault LTO4-120HH (IBM) Tape Drive which add support for v2 drives. This release contains A9Q2 drive firmware and ITDT-DCR version 1.2.0.005.
Recommended A9Q2/A233 12/1/2010 Windows Server 2008 x64
Windows Server 2008 x86
SuSE Linux ES 10
Windows Server 2003 x64
Windows Server 2003
Red Hat Enterprise Linux 4
SuSE Linux ES 9
Netware
Red Hat Enterprise Linux 5
    
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.2183, A05
Firmware version V21836406-852 for the Quantum LTO3-060 SAS drive.
Recommended 2183 1/6/2010 Windows Server 2003
Windows Server 2003 x64
Windows Server 2008 x86
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4
Windows Server 2008 x64
SuSE Linux ES 10
SuSE Linux ES 9
    
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.2183, A04
Firmware version V21836406-852 for the Quantum LTO3-060 SAS drive.
Recommended 2183 8/26/2009 Windows Server 2003
SuSE Linux ES 9
Windows Server 2003 x64
SuSE Linux ES 10
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4
Windows Server 2008 x64
Windows Server 2008 x86
    
Dell PowerVault 110T SDLT320, v.6262, A18
This release includes the following: firmware version v6262 (v100) DFU utility v1.3.10 - Firmware flash utility that updates one drive at a time. DUP - Automated Firmware flash utility, Windows and Linux only, that flashes all drives.
Recommended 6262 5/29/2009 Windows 2000
Windows Server 2003 x64
SuSE Linux ES 9
Red Hat Linux 6.2
Windows Server 2003
Red Hat Enterprise Linux 4
Windows NT 4.0
Red Hat Enterprise Linux 2.1
Red Hat Linux 7.0
Red Hat Linux 6.1
Red Hat Enterprise Linux 3
Netware
    
Dell Powervault 100T DAT72, v.A16J, A13
This is firmware verison A16J. This release includes the DFU (Dell Firmware Update) Utility which will allow users to update one device at a time as well as the DUP (Dell Update Package) Utility which can be used to update all devices automatically. A13 release includes a fix to change the C1
Recommended A16J 4/18/2009 Windows Server 2003 x64
Netware
Red Hat Enterprise Linux 2.1
Red Hat Enterprise Linux 4
SuSE Linux ES 9
Windows Server 2003
Windows Server 2008 x64
SuSE Linux ES 10
Red Hat Enterprise Linux 3
Windows Server 2008 x86
Windows NT 4.0
Windows Powered
Red Hat Enterprise Linux 5
Windows 2000
    
Dell PowerVault LTO3-060 (Quantum), v.2181, A02
Latest Quantum LTO3-060 SCSI drive firmware v2181 to address stuck tapes and failing backups.
Recommended 2181 4/10/2009 Red Hat Enterprise Linux 5
Windows Server 2008 x64
SuSE Linux ES 9
Red Hat Enterprise Linux 4
Windows Server 2003 x64
Windows Server 2003
SuSE Linux ES 10
Windows Server 2008 x86
    
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.2182, A03
Firmware version V21826406-852 for the Quantum LTO3-060 SAS drive.
Recommended 2182 4/10/2009 Windows Server 2003 x64
Windows Server 2003
Red Hat Enterprise Linux 4
SuSE Linux ES 9
Windows Server 2008 x64
Windows Server 2008 x86
SuSE Linux ES 10
Red Hat Enterprise Linux 5
    
Dell Powervault 100T DAT72, v.A16E, A11
Release incorporates firmware A16E from the A09 release and adds support for DUP, SUU, and ITA. Added DUP support for SLES operating systems
Recommended A16E 1/19/2009 SuSE Linux ES 9
Windows Server 2003
Windows Server 2003 x64
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 2.1
Netware
Windows 2000
Windows Powered
Red Hat Enterprise Linux 4
Windows NT 4.0
    
Dell PowerVault 110T DLT VS160, v.3200, A15
This release includes new firmware for the VS160 Tape Drive. This will replace any previous releases. Firmware will update to version 3200 (v50). This release includes DFU and DUP. The DFU utility is used to flash the firmware for Windows, Linux, and Netware one drive at a time. The DUP
Recommended 3200 12/17/2008 Windows NT 4.0
Windows Server 2003 x64
Red Hat Enterprise Linux 4
SuSE Linux ES 9
Windows 2000
Red Hat Linux 7.0
Red Hat Linux 6.2
Netware
Red Hat Enterprise Linux 3
Windows Server 2003
Red Hat Enterprise Linux 2.1
Red Hat Linux 6.1
    
Dell PowerVault 100T DDS4, v.912L, A19
Release incorporates existing firmware v912L from A16 release with added DUP support for SLES Linux.
Recommended 912L 12/17/2008 Red Hat Enterprise Linux 4
Windows Server 2003 x64
Windows 2000
Red Hat Enterprise Linux 3
Red Hat Linux 7.0
Red Hat Linux 6.2
Red Hat Linux 6.1
Red Hat Enterprise Linux 2.1
Windows NT 4.0
SuSE Linux ES 9
Windows Server 2003
Netware
    
Dell PowerVault 110T LTO-2-L (Certance), v.1914, A18
Release contains updated tape drive firmware version 1914. **DFU allows users to manually update one device at a time. **DUP will allow users to automatically update all supported devices at once.
Recommended 1914 12/17/2008 Netware
Red Hat Enterprise Linux 4
Red Hat Linux 9.0
Windows Server 2003
Windows 2000
Red Hat Enterprise Linux 2.1
Red Hat Linux 8.0
Windows Server 2003 x64
Windows NT 4.0
Red Hat Enterprise Linux 3
SuSE Linux ES 9
    
Dell PowerVault 110T SDLT320, v.5D5D, A17
This release contains the same firmware as the A14 release and adds DUP support for SLES10. This release includes the following: firmware version v5D5D (v93d) DFU utility v1.3.4 - Firmware flash utility that updates one drive at a time. DUP - Automated Firmware flash utility, Windows and
Recommended 5D5D 12/17/2008 Windows Server 2003 x64
Netware
Windows NT 4.0
Red Hat Enterprise Linux 3
Windows Server 2003
Red Hat Linux 6.2
Red Hat Enterprise Linux 4
Red Hat Linux 6.1
SuSE Linux ES 9
Red Hat Enterprise Linux 2.1
Red Hat Linux 7.0
Windows 2000
    
Dell PowerVault LTO4-120 (Quantum), v.2170, A03
This is the V2170 firmware release for the Quantum LTO4-120 tape drive, which is mounted in the PV114T and PV124T.
Recommended 2170 12/12/2008 Windows Server 2003
Windows Server 2008 x86
SuSE Linux ES 9
SuSE Linux ES 10
Windows Server 2008 x64
Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 5
    
Dell Powervault 100T DAT72, v.A16E, A12
Release incorporates firmware A16E from the A09 release and adds support for DUP, SUU, and ITA. Added DUP support for SLES operating systems
Recommended A16E 11/4/2008 Netware
Windows 2000
Red Hat Enterprise Linux 4
Windows Server 2003
Windows Server 2003 x64
Red Hat Enterprise Linux 2.1
SuSE Linux ES 9
Windows NT 4.0
Red Hat Enterprise Linux 3
Windows Powered
    
Dell PowerVault LTO4-120 (Quantum), v.2143, A02
This is the V2143 firmware release for the Quantum LTO4-120 tape drive, which is mounted in the PV114T and PV124T
Recommended 2143 7/16/2008 SuSE Linux ES 10
Red Hat Enterprise Linux 5
Windows Server 2003
Windows Server 2008 x86
Windows Server 2008 x64
SuSE Linux ES 9
Red Hat Enterprise Linux 4
    
Dell Powervault 114T Enclosure, PowerVault LTO3-060 SAS (Quantum), v.2076, A01
Firmware version V20766316-852 for the Quantum LTO3-060 SAS drive.
Recommended 2076 6/16/2008 Windows Server 2008 x86
Red Hat Enterprise Linux 5
Windows Server 2003
Windows Server 2003 x64
SuSE Linux ES 10
Windows Server 2008 x64
Red Hat Enterprise Linux 4
SuSE Linux ES 9
    
Dell PowerVault 110T DLT VS160, v.3200, A14
This release includes new firmware for the VS160 Tape Drive. This will replace any previous releases. Firmware will update to version 3200 (v50). This release includes DFU and DUP. The DFU utility is used to flash the firmware for Windows, Linux, and Netware one drive at a time. The DUP
Recommended 3200 8/15/2007 Red Hat Enterprise Linux 2.1
Windows NT 4.0
Windows 2000
Red Hat Linux 6.1
Windows Server 2003
Red Hat Enterprise Linux 3
SuSE Linux ES 9
Netware
Red Hat Linux 7.0
Red Hat Linux 6.2
Windows Server 2003 x64
Red Hat Enterprise Linux 4
    
Dell PowerVault 110T SDLT320, v.5D5D, A16
This release contains the same firmware as the A14 release and adds DUP support for SLES10. This release includes the following: firmware version v5D5D (v93d) DFU utility v1.3.4 - Firmware flash utility that updates one drive at a time. DUP - Automated Firmware flash utility, Windows and
Recommended 5D5D 8/15/2007 Red Hat Linux 6.2
Red Hat Linux 6.1
Red Hat Enterprise Linux 3
Netware
Red Hat Enterprise Linux 4
Red Hat Linux 7.0
Windows Server 2003 x64
Windows NT 4.0
SuSE Linux ES 9
Windows Server 2003
Windows 2000
Red Hat Enterprise Linux 2.1
    
Dell PowerVault 110T LTO, v.1614, A12
Release includes firmware previously released in the A10 revision. Added DUP support for SLES Linux **DFU is a tool included in the zip-pack and tar.gz format. This tool will allow users to manually update one drive at a time. **DUP utility (Dell Update Package) will allow users to
Recommended 1614 8/15/2007 Windows 2000
Windows Server 2003 x64
Red Hat Enterprise Linux 2.1
Red Hat Linux 6.1
SuSE Linux ES 9
Red Hat Linux 7.0
Windows Server 2003
Red Hat Linux 6.2
Windows NT 4.0
Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 3
Netware
    
Dell PowerVault 100T DDS4, v.912L, A18
Release incorporates existing firmware v912L from A16 release with added DUP support for SLES Linux.
Recommended 912L 8/15/2007 SuSE Linux ES 9
Red Hat Linux 7.0
Red Hat Enterprise Linux 4
Windows 2000
Netware
Red Hat Linux 6.2
Red Hat Enterprise Linux 2.1
Windows Server 2003 x64
Red Hat Linux 6.1
Windows NT 4.0
Red Hat Enterprise Linux 3
Windows Server 2003
    
Dell PowerVault 110T LTO-2-L (Certance), v.1914, A17
Release contains updated tape drive firmware version 1914. **DFU allows users to manually update one device at a time. **DUP will allow users to automatically update all supported devices at once.
Urgent 1914 8/15/2007 Windows Server 2003 x64
Windows 2000
Windows NT 4.0
Netware
SuSE Linux ES 9
Red Hat Linux 9.0
Windows Server 2003
Red Hat Linux 8.0
Red Hat Enterprise Linux 2.1
Red Hat Enterprise Linux 4
Red Hat Enterprise Linux 3
    

Tape Drives - Utility

Description Importance Version Released Supported OS Download
Dell PowerVault 100T DDS4, PowerVault 110T LTO, PowerVault 110T SDLT, PowerVault 110T DLT VS80, PowerVault 110T SDLT320, PowerVault 110T DLT VS160, Powervault 100T DAT72, Powervault 114T Enclosure, PowerVault 110T LTO-2-L (Certance), PowerVault LTO3-060 (Quantum), PowerVault LTO3-060 SAS (Quantum), PowerVault LTO4-120 (Quantum), v.6.2.0.7, A06
xTalk diagnostic utility for testing the Dell PowerVault 100T DAT72, 100T DDS4, 110T VS80, 110T VS160, 110T SDLT220, 110T SDLT320, 110T LTO1 (Certance) and 110T LTO2-L (Certance), LTO3-060 SCSI, LTO3-060 SAS, LTO4-120 SAS tape drives. Version 6.2.0.7. This download does not include firmware. It is
Recommended 6.2.0.7 5/20/2010 SuSE Linux ES 9
Red Hat Linux 7.0
Red Hat Linux 9.0
Red Hat Linux 8.0
Red Hat Linux 6.1
Red Hat Enterprise Linux 2.1
Red Hat Linux 7.1
Red Hat Linux 7.2
SuSE Linux ES 10
Red Hat Linux 6.2
Red Hat Enterprise Linux 3
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 4
Red Hat Linux 7.3
Dell PowerVault 100T DDS4, PowerVault 110T LTO, PowerVault 110T SDLT, PowerVault 110T DLT VS80, PowerVault 110T SDLT320, PowerVault 110T DLT VS160, Powervault 100T DAT72, Powervault 114T Enclosure, PowerVault 110T LTO-2-L (Certance), PowerVault LTO3-060 (Quantum), PowerVault LTO3-060 SAS (Quantum), PowerVault LTO4-120 (Quantum), v.6.1.2, A05
xTalk diagnostic utility for testing the Dell PowerVault 100T DAT72, 100T DDS4, 110T VS80, 110T VS160, 110T SDLT220, 110T SDLT320, 110T LTO1 (Certance) and 110T LTO2-L (Certance), LTO3-060 SCSI, LTO3-060 SAS, LTO4-120 SAS tape drives. Version 6.1.2. This download does not include firmware. It is
Recommended 6.1.2 6/11/2009 SuSE Linux ES 9
Red Hat Enterprise Linux 4
Red Hat Linux 7.3
Red Hat Linux 9.0
Red Hat Linux 7.0
Red Hat Enterprise Linux 2.1
Red Hat Linux 8.0
Red Hat Enterprise Linux 5
SuSE Linux ES 10
Red Hat Linux 7.2
Red Hat Linux 6.2
Red Hat Linux 7.1
Red Hat Linux 6.1
Red Hat Enterprise Linux 3

 

 

Video - Driver

Description Importance Version Released Supported OS Download
ATI Radeon 7000M, v.8.24.50.3-080121a-058688C, A00
Windows 2008 Video Driver for Radeon 7000M
Recommended 8.24.50.3-080121a-058688C 2/27/2008 Windows Server 2008 x86
Windows Server 2008 x64

 

-> Commander sur Dell.com, Cliquez ici

 

Autres manuels ou drivers :

Dell

[TXT]

 Dell-Product-support..> 18-May-2013 16:59  2.1M  

[TXT]

 Dell-Product-support..> 18-May-2013 16:59  2.1M  

[TXT]

 Dell-Product-support..> 18-May-2013 16:58  2.1M  

[TXT]

 Dell-Product-support..> 18-May-2013 16:58  2.1M  

[TXT]

 Dell-Product-support..> 18-May-2013 16:57  2.1M  

[TXT]

 Dell-Product-support..> 18-May-2013 16:57  2.1M  

[TXT]

 Dell-Manuals-for-Pow..> 18-May-2013 16:57  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 18-May-2013 16:57  2.6M  

[TXT]

 Dell-studio-xps-7100..> 18-May-2013 16:56  2.8M  

[TXT]

 Dell-pa-220.htm         18-May-2013 16:56  2.8M 

[TXT]

 Dell-Manuals-for-XPS..> 18-May-2013 10:56  2.2M  

[TXT]

 Dell-Manuals-for-XPS..> 18-May-2013 10:56  2.5M  

[TXT]

 Dell-Manuals-for-XPS..> 18-May-2013 10:56  2.5M  

[TXT]

 Dell-Manuals-for-Ins..> 18-May-2013 10:56  2.6M  

[TXT]

 Dell-Manuals-for-Ins..> 18-May-2013 10:55  2.9M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:55  3.0M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:54  3.1M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:54  3.2M  

[TXT]

 Dell-Manuals-for-Pre..> 18-May-2013 10:53  3.2M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:53  3.4M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:52  3.7M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:51  2.7M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:51  3.3M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:51  3.0M  

[TXT]

 Dell-Poweredge-2500.htm 18-May-2013 10:50  3.5M  

[TXT]

 Dell-Manuals-for-Lat..> 18-May-2013 10:50  3.5M  

[TXT]

 Dell-Drivers-for-Del..> 18-May-2013 10:48  2.1M  

[TXT]

 Dell-Manuals-for-Pow..> 18-May-2013 10:48  2.1M  

[TXT]

 Dell-Product-support..> 17-May-2013 21:34  2.0M  

[TXT]

 Dell-Product-support..> 17-May-2013 21:34  2.0M  

[TXT]

 Dell-Manuals-for-Pow..> 17-May-2013 21:33  2.0M  

[TXT]

 Dell-Product-support..> 17-May-2013 21:33  2.0M  

[TXT]

 Dell-xps-8300.htm       17-May-2013 21:33  2.0M  

[TXT]

 Dell-Manuals-for-XPS..> 17-May-2013 21:33  2.0M  

[TXT]

 Dell-Manuals-for-Ins..> 17-May-2013 21:03  2.0M 

[TXT]

 Dell-Manuals-for-Pow..> 17-May-2013 20:56  3.1M  

[TXT]

 Dell-Manuals-for-Ins..> 17-May-2013 20:56  2.0M  

[TXT]

 Dell-Product-support..> 17-May-2013 20:53  2.5M  

[TXT]

 Dell-Product-support..> 17-May-2013 20:53  2.5M  

[TXT]

 Dell-2-Manuals-for-D..> 17-May-2013 20:52  2.5M  

[TXT]

 Dell-Product-support..> 17-May-2013 20:52  2.5M  

[TXT]

 Dell-Manuals-for-Ins..> 17-May-2013 20:51  2.8M  

[TXT]

 Dell-Manuals-for-XPS..> 17-May-2013 20:51  2.7M  

[TXT]

 Dell-Manuals-for-Pow..> 17-May-2013 20:50  2.9M  

[TXT]

 Dell-Manuals-for-Pow..> 17-May-2013 20:50  2.9M  

[TXT]

 Dell-Manuals-for-Pow..> 17-May-2013 20:49  2.9M  

[TXT]

 Dell-Product-support..> 17-May-2013 20:49  2.9M 

[TXT]

 Dell-Product-support..> 15-May-2013 07:01  1.7M  

[TXT]

 Dell-Product-support..> 15-May-2013 07:01  1.7M  

[TXT]

 Dell-Manuals-for-Del..> 15-May-2013 07:01  1.7M  

[TXT]

 Dell-Manuals-for-Del..> 15-May-2013 07:00  1.7M  

[TXT]

 Dell-Manuals-for-Ins..> 15-May-2013 07:00  1.7M  

[TXT]

 Dell-Manuals-for-Pre..> 15-May-2013 07:00  1.9M  

[TXT]

 Dell-Manuals-for-XPS..> 15-May-2013 07:00  1.7M  

[TXT]

 Dell-Manuals-for-Min..> 15-May-2013 06:59  1.9M  

[TXT]

 Dell-Manuals-for-W50..> 15-May-2013 06:59  2.0M  

[TXT]

 Dell-Manuals-for-XPS..> 15-May-2013 06:59  2.0M  

[TXT]

 Dell-Manuals-for-Pow..> 15-May-2013 06:59  2.0M  

[TXT]

 Dell-Manuals-for-Pow..> 15-May-2013 06:58  2.1M  

[TXT]

 Dell-Manuals-for-Stu..> 15-May-2013 06:58  2.1M  

[TXT]

 Dell-Manuals-for-Del..> 15-May-2013 06:57  2.5M  

[TXT]

 Dell-Manuals-for-Stu..> 15-May-2013 06:57  2.2M

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 11:57  2.7M  

[TXT]

 Dell-Product-support..> 13-May-2013 11:57  2.7M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 11:56  3.2M  

[TXT]

 Dell-Product-support..> 13-May-2013 11:56  3.2M  

[TXT]

 Dell-Product-support..> 13-May-2013 11:55  1.5M  

[TXT]

 Dell-Manuals-for-Lat..> 13-May-2013 11:55  1.6M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 11:55  1.5M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 08:04  2.7M  

[TXT]

 Dell-Manuals-for-Pre..> 13-May-2013 08:02  2.5M  

[TXT]

 Dell-Manuals-for-XPS..> 13-May-2013 08:02  2.5M  

[TXT]

 Dell-Manuals-for-Min..> 13-May-2013 08:01  2.6M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:43  2.1M  

[TXT]

 Dell-Manuals-for-XPS..> 13-May-2013 07:43  2.3M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:43  2.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 07:42  2.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 07:42  2.3M  

[TXT]

 Dell-Manuals-for-Pre..> 13-May-2013 08:02  2.5M  

[TXT]

 Dell-Manuals-for-XPS..> 13-May-2013 08:02  2.5M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 08:01  2.7M  

[TXT]

 Dell-Manuals-for-Min..> 13-May-2013 08:01  2.6M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:43  2.1M  

[TXT]

 Dell-Manuals-for-XPS..> 13-May-2013 07:43  2.3M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:43  2.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 07:42  2.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 07:42  2.3M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:21  1.6M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:21  1.6M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:20  1.7M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:20  1.6M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:20  1.9M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 07:20  1.8M

[TXT]

 Dell-Product-support..> 12-May-2013 19:02  2.8M  

[TXT]

 Dell-Manuals-for-Ins..> 12-May-2013 19:02  2.9M  

[TXT]

 Dell-Manuals-for-Ali..> 12-May-2013 19:02  3.0M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 19:01  3.1M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 19:01  3.3M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 19:00  3.4M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 19:00  3.5M  

[TXT]

 Dell-Manuals-for-Ins..> 12-May-2013 18:58  3.5M  

[TXT]

 Dell-Manuals-for-Lat..> 12-May-2013 18:58  3.4M  

[TXT]

 Dell-Manuals-for-Lat..> 12-May-2013 18:28  2.8M

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 18:19  2.5M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 18:19  2.2M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 18:18  2.6M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 18:18  2.6M  

[TXT]

 Dell-Manuals-for-XPS..> 12-May-2013 18:17  2.6M  

[TXT]

 Dell-Product-support..> 12-May-2013 18:17  2.6M  

[TXT]

 Dell-Manuals-for-Lat..> 12-May-2013 18:17  2.6M  

[TXT]

 Dell-Product-support..> 12-May-2013 18:16  2.6M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 17:43  2.1M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 17:39  2.1M 

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 12:35  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 12:35  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 12:34  3.0M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 12:34  2.9M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 12:33  3.3M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 12:33  3.3M  

[TXT]

 Dell-Manuals-for-Lat..> 12-May-2013 12:32  3.5M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 12:32  3.5M 

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 17:39  2.1M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 17:39  2.1M  

[TXT]

 Dell-Manuals-for-Lat..> 12-May-2013 17:38  3.5M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 17:38  3.5M  

[TXT]

 Dell-Manuals-for-Vos..> 12-May-2013 17:38  3.6M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 17:37  3.6M  

[TXT]

 Dell-Manuals-for-Ins..> 12-May-2013 17:36  3.7M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 17:35  3.7M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 17:35  4.0M  

[TXT]

 Dell-Manuals-for-XPS..> 12-May-2013 17:35  1.9M  

[TXT]

 Dell-Manuals-for-Opt..> 12-May-2013 17:34  2.0M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 17:34  2.0M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 17:33  2.0M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 17:33  2.0M 

[TXT]

 Dell-Drivers-for-Del..> 12-May-2013 12:05  4.2M  

[TXT]

 Dell-Product-support..> 12-May-2013 12:05  4.1M  

[TXT]

 Dell-Product-support..> 12-May-2013 12:04  4.1M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 12:04  4.3M  

[TXT]

 Dell-Product-support..> 12-May-2013 12:02  4.3M  

[TXT]

 Dell-Drivers-for-Pow..> 12-May-2013 12:02  4.3M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 12:01  2.2M  

[TXT]

 Dell-Product-support..> 12-May-2013 12:01  2.2M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 12:00  2.5M  

[TXT]

 Dell-Product-support..> 12-May-2013 12:00  2.2M  

[TXT]

 Dell-Product-support..> 12-May-2013 11:59  2.5M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 11:59  2.5M  

[TXT]

 Dell-Manuals-for-Del..> 12-May-2013 11:59  2.7M  

[TXT]

 Dell-Product-support..> 12-May-2013 11:59  2.7M  

[TXT]

 Dell-Manuals-for-LCD..> 12-May-2013 11:58  2.7M  

[TXT]

 Dell-Product-support..> 12-May-2013 11:58  2.7M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 11:57  2.8M  

[TXT]

 Dell-Product-support..> 12-May-2013 11:57  2.7M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 11:56  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 12-May-2013 11:56  2.8M 
 Dell-Latitude-E6530-..> 10-May-2013 15:25  2.4M  
 Dell-Latitude-CPi-A-..> 10-May-2013 15:24  2.7M  
 Dell-Configurer-et-u..> 10-May-2013 15:24  2.7M  
 Dell-Latitude-D410-M..> 10-May-2013 15:24  3.0M  
 Dell-Symantec-Backup..> 10-May-2013 15:23  3.0M  
 Dell-PowerEdge-R510-..> 10-May-2013 15:23  3.4M  
 Dell-Studio-1735-Man..> 10-May-2013 15:22  3.1M  
 Dell-Latitude-D620-E..> 10-May-2013 15:21  3.7M  
 Dell-Latitude-E6430-..> 10-May-2013 15:21  3.4M  
 Dell-Inspiron-9400-M..> 10-May-2013 15:20  4.1M  
 Dell-Latitude-E6410-..> 10-May-2013 15:20  3.8M  
 Dell-Latitude-E6400-..> 10-May-2013 15:19  4.3M  
 Dell-Alienware-Area-..> 10-May-2013 15:19  4.1M
 Dell-PowerEdge-T710-..> 10-May-2013 14:23  2.9M  
 Dell-PowerEdge-T420-..> 10-May-2013 14:23  3.2M  
 Dell-UPS-500T-Manuel..> 10-May-2013 14:22  3.4M  
 Dell-PowerConnect-55..> 10-May-2013 14:22  4.5M  
 Dell-UPS-500- Englis..> 10-May-2013 14:21  4.6M  
 Dell-UPS-500T-Españ..> 10-May-2013 14:20  1.7M  
 Dell-OptiPlex-330-Ma..> 10-May-2013 14:20  2.2M  
 Dell-Inspiron-1520-E..> 10-May-2013 14:20  1.9M  
 Dell-Latitude-E6530-..> 10-May-2013 14:19  2.4M  
 Dell-Latitude-E6530-..> 10-May-2013 14:19  2.3M  
 Dell-PowerEdge-T605-..> 10-May-2013 13:46  2.8M  
 Dell-7330dn-Mono-Las..> 10-May-2013 13:41  2.8M  
 Dell-Alienware-X51-M..> 10-May-2013 13:41  2.7M  
 Dell-Comment-utilise..> 10-May-2013 13:41  2.7M 
 Dell-Latitude-D630-M..> 10-May-2013 11:17  4.7M  
 Dell-Precision-690-M..> 10-May-2013 11:16  3.2M  
 Dell-Latitude-E6400-..> 10-May-2013 11:16  3.9M  
 Dell-Precision-M40-M..> 10-May-2013 11:15  3.9M  
 Dell-Precision-360-M..> 10-May-2013 11:15  4.0M  
 Dell-PowerEdge-R320-..> 10-May-2013 11:14  4.4M  
 Dell-Precision-450-M..> 10-May-2013 11:13  4.6M  
 Dell-Intel-Active-Ma..> 10-May-2013 11:13  4.7M  
 Dell-OptiPlex-755-Ma..> 10-May-2013 11:12  5.5M  
 Dell-PowerVault-NX30..> 10-May-2013 11:12  5.6M  
 Dell-Precision-M4500..> 10-May-2013 11:10  6.1M  
 Dell-OptiPlex-SX280-..> 10-May-2013 11:10  6.0M  
 Dell-Latitude-E6400-..> 10-May-2013 10:30  3.2M  
 Dell-PowerEdge-T100-..> 10-May-2013 10:22  3.0M  
 Dell-Vostro-270s-Man..> 10-May-2013 10:21  3.1M  
 Dell-Precision-T7600..> 10-May-2013 10:21  3.2M  
 Dell-Precision-M4400..> 10-May-2013 10:20  3.3M  
 Dell-Precision-M4700..> 10-May-2013 10:20  3.4M  
 Dell-Precision-M4600..> 10-May-2013 10:19  3.4M  
 Dell-Precision-390-M..> 10-May-2013 10:19  2.0M  
 Dell-Precision-610-M..> 10-May-2013 10:18  2.3M  
 Dell-Manuel-d-utilis..> 10-May-2013 10:18  2.3M  
 Dell-Precision-M20-M..> 10-May-2013 10:17  2.8M  
 Dell-Guide-d-utilisa..> 10-May-2013 10:17  2.8M  
 Dell-Precision-370-M..> 10-May-2013 10:16  3.2M 
 Dell-PowerEdge-T100-..> 10-May-2013 10:22  3.0M  
 Dell-Vostro-270s-Man..> 10-May-2013 10:21  3.1M  
 Dell-Precision-T7600..> 10-May-2013 10:21  3.2M  
 Dell-Precision-M4400..> 10-May-2013 10:20  3.3M  
 Dell-Precision-M4700..> 10-May-2013 10:20  3.4M  
 Dell-Precision-M4600..> 10-May-2013 10:19  3.4M  
 Dell-Precision-390-M..> 10-May-2013 10:19  2.0M  
 Dell-Precision-610-M..> 10-May-2013 10:18  2.3M  
 Dell-Manuel-d-utilis..> 10-May-2013 10:18  2.3M  
 Dell-Precision-M20-M..> 10-May-2013 10:17  2.8M  
 Dell-Guide-d-utilisa..> 10-May-2013 10:17  2.8M  
 Dell-Precision-370-M..> 10-May-2013 10:16  3.2M  
 Dell-Latitude-E6400-..> 10-May-2013 10:16  3.2M  
 Dell-XPS-M1210-Owner..> 08-May-2013 10:57  2.9M  
 Dell-Windows-8-Manue..> 08-May-2013 10:54  5.1M  
 Dell-PowerEdge-R815-..> 08-May-2013 10:52  4.3M  
 Dell-Inspiron-1521-M..> 08-May-2013 10:51  2.9M  
 Dell-PowerEdge-R900-..> 08-May-2013 10:50  3.1M  
 Dell-Vostro-270-Manu..> 08-May-2013 10:50  3.2M  
 Dell-XPS-630-Manuels..> 08-May-2013 10:49  3.6M  
 Dell-XPS-M1730-Manue..> 08-May-2013 10:49  3.9M  
 Dell-Vostro-200-Manu..> 08-May-2013 10:48  4.5M  
 Dell-Vostro-410-Manu..> 08-May-2013 10:48  4.1M  
 Dell-Vostro-1700-Man..> 08-May-2013 10:47  4.8M  
 Dell-Inspiron-m301z-..> 08-May-2013 10:47  4.8M  
 Dell-Studio-Slim-Man..> 08-May-2013 10:45  5.1M  
 Dell-PowerEdge-R620-..> 08-May-2013 08:46  4.1M  
 Dell-PowerEdge-R200-..> 08-May-2013 08:46  2.6M  
 Dell-Inspiron-640M-M..> 08-May-2013 08:46  3.7M  
 Dell-Inspiron-600m-M..> 08-May-2013 08:45  2.6M  
 Dell-Studio-Desktop-..> 08-May-2013 08:44  2.7M  
 Dell-Vostro-1000-Man..> 08-May-2013 08:44  2.7M  
 Dell-Inspiron-15-Int..> 08-May-2013 08:44  3.0M  
 Dell-Alienware-Area-..> 08-May-2013 08:43  3.1M  
 Dell-DR4000-Manuels.htm 08-May-2013 08:43  3.4M  
 Dell-Alienware-M15x-..> 08-May-2013 08:42  3.3M  
 Dell-Latitude-XT2-Ma..> 08-May-2013 08:42  3.5M  
 Dell-Latitude-E5520-..> 08-May-2013 08:41  3.5M  
 Dell-OptiPlex-745-Ma..> 08-May-2013 08:40  3.9M  
 Dell-Inspiron-1525-M..> 08-May-2013 08:40  3.9M  
 Dell-Inspiron-One-23..> 08-May-2013 08:39  4.2M  
 Dell-Inspiron-One-23..> 08-May-2013 08:39  2.8M  
 Dell-Inspiron-510m-M..> 08-May-2013 08:38  3.2M  
 Dell-Inspiron-Duo-Ma..> 08-May-2013 08:38  3.0M  
 Dell-Vostro-1550-Man..> 08-May-2013 08:37  3.4M  
 Dell-Precision-T5600..> 08-May-2013 08:37  3.3M  
 Dell-Dimension-8300-..> 07-May-2013 22:03  2.5M  
 Dell-Latitude-Cpi-Ma..> 07-May-2013 22:01  3.2M  
 Dell-Alienware-Area-..> 07-May-2013 22:01  3.2M  
 Dell-Latitude-D620-M..> 07-May-2013 22:00  2.3M  
 Dell-PowerEdge-1950-..> 07-May-2013 22:00  2.2M  
 Dell-Precision-T5600..> 07-May-2013 21:30  3.1M  
 Dell-PowerEdge-R720x..> 07-May-2013 21:26  3.1M  
 Dell-Inspiron-500m-M..> 07-May-2013 21:26  2.8M  
 Dell-PowerEdge-R815-..> 07-May-2013 21:25  2.8M  
 Dell-Alienware-M15x-..> 07-May-2013 21:25  2.8M  
 Dell-Vostro-3450-Man..> 07-May-2013 21:24  2.8M  
 Dell-PowerEdge-R610-..> 07-May-2013 21:24  2.9M  
 Dell-Vostro-3750-Man..> 07-May-2013 21:23  3.0M  
 Dell-Studio-1555-15-..> 07-May-2013 21:23  3.1M  
 Dell-Manuel-de-maint..> 07-May-2013 21:22  3.0M  
 Dell-Latitude-E6420-..> 07-May-2013 21:22  3.1M  
 Dell-Inspiron-1520-M..> 07-May-2013 21:21  2.0M  
 Dell-Aztech-MDP3900-..> 07-May-2013 21:21  2.0M  
 Dell-PowerEdge-M905-..> 07-May-2013 21:21  2.0M  
 Dell-PowerEdge-400SC..> 07-May-2013 21:21  2.1M  
 Dell-Precision-M4500..> 07-May-2013 21:20  2.2M  
 Dell-Vizioncore-Manu..> 07-May-2013 21:20  2.1M  
 Dell-Inspiron-1520-2..> 07-May-2013 21:19  2.5M  
 Dell-Guide-Utilisate..> 07-May-2013 21:19  2.4M  
 Dell-PowerEdge-R510-..> 07-May-2013 21:18  2.7M  
 Dell-Manuel-d-Utilis..> 07-May-2013 21:18  2.4M  
 Dell-PowerEdge-300-M..> 06-May-2013 19:33  4.7M  
 Dell-Lifecycle-Contr..> 06-May-2013 19:32  4.3M  
 Dell-PowerVault-110T..> 06-May-2013 19:31  4.4M  
 Dell-Inspiron-620-Ma..> 06-May-2013 19:10  3.2M  
 Dell-Dimension-5100-..> 06-May-2013 19:10  3.4M  
 Dell-Manuels-et-docu..> 06-May-2013 19:09  3.7M  
 Dell-Manuels-et-docu..> 06-May-2013 19:09  3.5M  
 Dell-1130-Dell-1130n..> 06-May-2013 18:42  3.1M

Dell-Controleurs-RAID-Dell-PowerEdge-PERC-H310-H710-H710P-et-H810-Guide-d-utilisation

Dell-Laser-MFP-Dell-3333dn-et-3335dn-Guide-de-l-utilisateur

Dell-PowerVault-DL-Backup-to-Disk-Appliance-Powered-by-Symantec-Backup-Exec-Guide-d-utilisation

Dell-XPS-015-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerVault-NX3300-Guide-de-mise-en-route

Dell-INSPIRON-GUIDE-DE-REFERENCE

Dell-Systemes-Dell-PowerVault-Network-Attached-Storage-NAS-Guide-de-depannage

Dell-Commutateur-de-consoles-2161DS-Dell-Guide-de-l-utilisateur-d-OSCAR-et-du-materiel

Dell-PowerEdge-T420-Guide-de-mise-en-route

Dell-PowerEdge-C8000XD-Manuel-du-proprietaire-du-materiel

Dell-OptiPlex-755-Guide-d-utilisation

Dell-Matrices-de-stockage-Dell-PowerVault-MD3200i-et-MD3220i-Guide-de-deploiement

Dell-Latitude-E5400-et-E5500-Guide-de-configuration-et-de-reference-rapide

Dell-Set-Up-Your-Computer

Dell-Manuel-du-proprietaire-du-Dell-XPS-M1730-Manuel

Dell-Systemes-Dell-PowerEdge-M620-Manuel-du-proprietaire-Manuel

Dell-PowerEdge-C410x-Getting-Started-With-Your-System

Dell-Systemes-Dell-PowerEdge-SUSE-Linux-Enterprise-Server-10-Instructions-d-installation

Dell-Utilitaires-de-gestion-du-Dell-OpenManage-Baseboard-Management-Controller-Version%204.6-Guide-d-utilisation

Dell-OpenManage-Server-Administrator-Guide-d-installation-de-la-version-7.1

Dell-Systeme-Dell-DR4000-Guide-de-l-administrateur

Dell-Systemes-Dell-PowerEdge%20Red-Hat-Enterprise-Linux-6-x86_64-x86-Instructions-d-installation-et-informations-importantes

Dell-Integrated-Dell-Remote-Access-Controller-7-iDRAC7-Version-1.20.20-Guide-d-utilisation

Dell-Management-Plug-In-pour-VMware-vCenter-Version-1.5-Guide-d-utilisation

Dell-Projecteur-7700FullHD-Dell-Guide-de-l-utilisateur

Dell-Projecteur-Dell-1420X-1430X-Guide-d-utilisation

Dell-FluidFS-NAS-Solutions-Guide-de-l-administrateur

Dell-PowerEdge-Express-SSD-PCIe-Flash-Guide-d-utilisation

Dell-Update-Packages-DUP-Version-7.0-Guide-d-utilisation

Dell-PowerEdge-R720-et-R720xd-Guide-de-mise-en-route-Manuel

Dell-PowerEdge-R320-Guide-de-mise-en-route

Dell-Systemes-Dell-PowerEdge-R510-Manuel-du-proprietaire

Dell-Precision-M4400-Guide-de-configuration-et-de-reference-rapide

Dell-Matrices-de-stockage-SCSI-Dell-EqualLogic-PS-Series-a-clusters-de-basculement-Microsoft-Windows-Server-Guide-d-installation-et-de-depannage-du-materie

Dell-PowerEdge-C410x-Guide-de-mise-en-route-du-systeme

Dell-Moniteur-a-ecran-plat-Dell-U2713HM-Guide-d-utilisation

Dell-Moniteur-a-Dell-P1913-P1913S-P2213

Dell-Guide-de-l-utilisateur-du-moniteur-Dell-E1913S-E1913-E2213

Dell-Systems-Service-and-Diagnostics-Tools-Version-7.0-Guide-d-installation-rapide

Dell-Moniteur-a-Dell-S2740L-Guide-d-utilisation

Dell-INSPIRON-GUIDE-DE-CONFIGURATION

Dell-Dimension-Serie-8300

Dell-PowerEdge-R820-Guide-de-mise-en-route

Dell-PowerEdge-C8000-Manuel-du-proprietaire-du-materiel-manuel

Dell-OpenManage-Server-Administrator-Version-7.1-Guide-d-utilisation

Dell-PowerEdge-M1000e-M915-M910-M820-M710HD-M710-M620-M610x-M610-M520-et-M420-Guide-de-mise-en-route

Dell-OpenManage-Server-Administrator-Version-7.0-Guide-d-installation

Dell-Inspiron-15R-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerVault-NX3200-Guide-de-mise-en-route

Dell-PowerEdge-RAID-Controller-PERC-S110-Guide-d-utilisation

Dell-FluidFS-NAS-Solutions-Guide-de-mise-en-route

Dell-Micrologiciel-Dell-Chassis-Management-Controller-Version-4-1-Guide-d-utilisation

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Guide-de-mise-en-route

Dell-Vostro-470-Manuel-du-proprietaire

/Dell-Systeme-Dell-PowerVault-NX3500-Guide-de-l-administrateur

Dell-Latitude-E6420-XFR-Guide-technique

Dell-Guide-de-l-utilisateur-du-moniteur-S2240M-S2340M

Dell-Systemes-Dell-DR4000-Manuel-du-proprietaire-manuel

Dell-PowerEdge-T320-Guide-de-mise-en-route

Dell-Precision-Workstation-T3600-Manuel-du-proprietaire

Dell-Systemes-Dell-DR4000-Manuel-du-proprietaire

Dell-PowerEdge-R420-Guide-de-mise-en-route

Dell-PowerEdge-C8220-Manuel-du-proprietaire-du-materiel-manuel

Dell-Vostro-470-Owner-s-Manual

Dell-Projecteur-Dell-M110-Guide-de-l-utilisateur

Dell-Upgrading-to-BackupExec-2012-PowerVault-DL-Backup-to-Disk-Appliance

Dell-PowerVault-NX3300-Manuel-du-proprietaire

Dell-PowerConnect-5500-Series-CLI-Reference-Guide

Dell-Matrices-de-stockage-Dell-PowerVault-MD3260-Series-Guide-de-deploiement

Dell-Inspiron-One-2020-Manuel-du-proprietaire

Dell-XPS-14-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-1900-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-M620-Manuel-du-proprietaire

Dell-PowerEdge-R815-Manuel-du-proprietaire

Dell-PowerEdge-R720-and-R720xd-Owner-s-Manual

Dell-Micrologiciel-Dell-Chassis-Management-Controller-Version-4.0-Guide-d-utilisation

Dell-Inspiron-17R-Manuel-du-proprietaire-Manuel

Dell-Inspiron-One-2020-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-C5220-Manuel-du-proprietaire-du-materiel

Dell-Inspiron-660s-Manuel-du-proprietaire-manuel

Dell-PowerEdge-R820-Manuel-du-proprietaire

Dell-Vostro-270-Manuel-du-proprietaire-manuel

Dell-Systeme-Dell-PowerEdge-C6220-Manuel-du-proprietaire

Dell-Inspiron-14R-Manuel-du-proprietaire

Dell-Guide-de-l-Utilisateur-de-l-Ecran-Large-Dell-IN1940MW

Dell-Moniteur-a-Dell-S2440L-Guide-d-utilisation

Dell-Alienware-X51-Owner-s-Manual

Dell-ALIENWARE-M17x-MOBILE-MANUAL

Dell-Emplacement-des-cavaliers-de-la-carte-systeme-des-systemes-Dell-PowerEdge-R310-Mise-a-jour-des-informations

Dell-Systemes-Dell-PowerEdge-6950-Manuel-du-proprietaire

Dell-Alienware-M17x-R4-Owner-s-Manual

Dell-XPS-13-Owner-s-Manual

Dell-HBA-SAS-Dell-PowerEdge-6-Gb-s-et-Internal-Tape-Adapter-Guide-d-utilisation

Dell-Systemes-Dell-PowerEdge-R910-Mise-a-jour-des-informations

Dell-Systemes-Dell-PowerEdge-T610-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R420-Manuel-du-proprietaire

/Dell-PowerEdge-R905-Manuel-du-proprietaire

Dell-Imprimantes-laser-Dell-2350d-et-Dell-2350dn

Dell-XPS-430-Guide-de-reference-rapide

Dell-PowerEdge-RAID-Controller-PERC-H700-et-H800-Guide-d-utilisation

Dell-Lifecycle-Controller-2-Version-1.00.00-User-s-Guide

Dell-OpenManage-Server-Administrator-Version-7.0-Guide-d-utilisation

Dell-Solutions-NAS-Dell-FluidFS-Manuel-du-proprietaire-Manue

Dell-Guide-de-l-utilisateur-Dell-V525w

Dell-XPS-13-Manuel-du-proprietaire

Dell-Adaptateurs-Brocade-Manuel-d-installation-et-de-reference

Dell-FluidFS-NAS-Solutions-NX3600-NX3610-Guide-de-deploiement

Dell-Systemes-Dell-PowerEdge-T410-Manuel-du-proprietaire

Dell-Latitude-ST-Manuel-du-proprietaire-Manuel

Dell-OptiPlex-360-Guide-de-configuration-et-de-reference-rapide

Dell-PowerEdge-R810-Manuel-du-proprietaire-du-materiel

Dell-Guide-d-installation-des-systemes-Dell-PowerVault-Modular-Disk-3000

Dell-Imprimante-laser-Dell-2230d-Guide-de-l-utilisateur

Dell-Systemes-Dell-PowerEdge-C6105-Manuel-du-proprietaire-du-materiel

Dell-Imprimante-personnelle-a-jet-d-encre-Dell-J740-Manuel-du-proprietaire

Dell-2130cn-IMPRIMANTE-LASER-COULEUR

Dell-Guide-d-utilisation-de-la-station-de-travail-Dell-Precision-T3400

Dell-1235cn-Imprimante-Multifonction-Mode-d-emploi

Dell-Vostro-1310-1510-1710-et-2510-Guide-de-configuration-et-de-reference-rapide

Dell-Guide-d-utilisation-APC-Smart-UPS-750VA-1000VA-1500VA-100-120-230-V-CA-2U-Montage-en-baie-Onduleur

Dell-Guide-d-utilisation-Modele-TL24iSCSIxSAS%201Gb-iSCSI-a-SAS

Dell-Imprimantes-laser-Dell-1130-et-Dell-1130n

Dell-Precision-M6400-Guide-de-configuration-et-de-reference-rapide

Dell-M770mm-Color-Monitor-Quick-Set-up

Dell-Carte-de-gestion-reseau-AP9617-AP9618-AP9619-Manuel-d-installation-et-de-demarrage-rapide

Dell-Projecteur-Dell-1410X-Guide-d-utilisation

Dell-Imprimante-couleur-Dell-1350cnw

Dell-Manuel-d-utilisation-Dell-Inspiron-M5040-15-N5040-15-N5050-Manuel

Dell-Manuel-de-maintenance-Dell-Inspiron-620

Dell-3D-VISION-MANUEL-D-UTILISATION

Dell-Inspiron-600m-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R805-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R900-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-2970-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-C6145-Manuel-du-proprietaire-du-materiel

Dell-Inspiron-660s-Manuel-du-proprietaire

Dell-P513w-User-s-Guide-Francais-manuel

Dell-Inspiron-660-manuels

Dell-Serveur-de-sauvegarde-sur-disque-Dell-PowerVault-DL-optimise-par-CommVault-Simpana-Guide-d-utilisation

Dell-P513w-User-s-Guide-Guide-de-l-utilisateur-manuel

Dell-Precision-Workstation-T1650-Manuel-du-proprietaire

Dell-ALIENWARE-M17x-MANUEL-DE-L-ORDINATEUR-PORTABLE

Dell-Manuel-du-proprietaire-de-Dell-PowerEdge-M905-M805-M600-et-M605

Dell-Inspiron-One-2330-Manuel-du-proprietaire

Dell-Dimension-1100-B110-Manuel-du-proprietaire

Dell-Vostro-270-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T320-Manuel-du-proprietaire

Dell-Station-de-travail-mobile-Dell-Precision-M4700-Manuel-du-proprietaire

Dell-XPS-8500-Manuel-du-proprietaire

Dell-1230c-Imprimante-laser-couleur-mode-d-emploi-Manuel

Dell-Client-Management-Manuel

Dell-Studio-XPS-Setup-Guide-Manue

Dell-Adaptateur-hote-Dell-PCIe-SCSI-Ultra320-monocanal-Guide-d-utilisation-Manuel

Dell-INSPIRON-DUO-SETUP-GUIDE-Manuel

Dell-INSPIRON-DUO-GUIDE-DE-CONFIGURATION-Manuel

Dell-Guide-de-l-utilisateur-Dell-Inspiron-M4040-14-N4050-Manuel

Dell-Guide-de-l-administrateur-de-Dell-PowerVault-705N-Manuel

Dell-Vostro-420-220-220s-Guide-de-Configuration-et-de-Reference-Rapide-Manuel

Dell-Matrices-de-stockage-Dell-PowerVault-MD3660f-Series-Guide-de-deploiement-Manuel

Dell-Systemes-Dell-PowerVault-Network-Attached-Storage-NAS-Guide-de-l-administrateur-Manuel

Dell-Latitude-D430-Guide-d-utilisation-Manuel

Dell-Studio-XPS-Guide-de-configuration-Manuel

Dell-PowerEdge-C410x-Manuel-du-proprietaire

Dell-Precision-Workstation-T1650-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R300-Manuel-du-proprietaire

Dell-Systemes%20-Dell%20PowerEdge-T110-II-Manuel-du-proprietaire

Dell-Vostro-200-Manuel-du-proprietaire-Mini-Tower

Dell-Inspiron-531-Manuel-du-proprietaire

Dell-ALIENWARE-MANUEL-DE-L-ORDINATEUR-DE-BUREAU-Francais

Dell-PowerEdge-R520-Manuel-du-proprietaire

Projecteur-Dell-1201MP-Manuel-d-utilisation

Dell-PowerEdge-R910-Manuel-du-proprietaire

Dell-Dimension-C521-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T605-Manuel-du-proprietaire

Dell-Mobile-Jamz

Dell-Inspiron-530-Series-Manuel-du-proprietaire

Dell-Vostro-3460-Manuels

Dell-OPENMANAGE-POWER-CENTER-1.1-Guide-d-utilisation

Dell-PowerVault-MD3660f-Storage-Arrays-Manuels

Dell™ Ekran Yöneticisi Kullanıcı Kılavuzu

Dell-PowerEdge-R620-Guide-de-mise-en-route

Dell-PowerEdge-R520-Guide-de-mise-en-route

DELL-POWERVAULT-MD1200-et-MD1220-TECHNICAL-GUIDEBOOK

Console-de-gestion-multi-onduleurs-Dell-Manuel-de-l-utilisateur-pour-l-installation-et-la-configuration

DELL-OPTIPLEX580-TECHNICAL-GUIDEBOOK-INSIDE-THE-OPTIPLEX-580

Dell-Inspiron-1720-manuels

Dell-PowerEdge-R720-et-R720xd-Guide-de-mise-en-route

Dell-Vostro-1540-1550-Manuel-du-proprietaire

Dell-Latitude-E5430-Manuel-du-proprietaire

Dell™ S2240L/S2340L Monitör Kullanıcı Kılavuzu

Dell PowerEdge Sistemleri İçin Microsoft Windows Server 2012 Önemli Bilgiler Kılavuzu

Dell-Guide-de-l-utilisateur-du-moniteur-Dell-S2240L-S2340L

Dell™ S320/S320wi Projektör Kullanım Kılavuzu

Dell-%20Vostro-270-Manuels

Dell-Vostro-3460-Manuel-du-proprietaire-Francais

Dell-Inspiron-9200-Manuel-de-l-utilisateur

Dell-Inspiron-2600-et-2650-Manuel-de-l-utilisateur

Dell-Axim-X30-Manuel-de-l-utilisateur

Dell-Vostro-2520-Manuel-du-proprietaire

Dell-Inspiron-1721-Manuel

Dell-Systemes-Dell-PowerEdge-T710-Manuel-du-proprietaire

Dell-Precision-Workstation-T5600-Manuel-du-proprietaire

Dell-Solutions-NAS-Dell-FluidFS-Manuel-du-proprietaire

Systemes-Dell-PowerEdge-C5220-Manuel-du-proprietaire-du-materiel

Dell-Dimension-3000-Manuel-du-proprietaire

Dell-PowerEdge-R210-Technical-Guide

Dell-Inspiron-Manuels

Dell-Manuel-du-proprietaire-du-Dell-Vostro-1700

Dell-Clavier-sans-fil-et-souris-Dell-KM713-Manuel-de-l'utilisateur

Dell-Systeme-de-navigation-GPS-Dell-Manuel-de-l'utilisateur

Dell-Logiciel-de-gestion-de-l-onduleur-Manuel-de-l-utilisateur-pour-l-installation-et-la-configuration

Dell-Demarrage-rapide-du-moniteur-couleur-M990

Dell-Manuel-de-l-utilisateur-de-la-station-de-travail-Dell-Precision-370

Dell-Systemes-Dell-PowerEdge-2800-Guide-d-installation-et-de-depannage

Dell-Manuel-de-l-utilisateur-du-systeme-Dell-OptiPlex-SX280

Dell-Vostro-1440-1450-Manuel-de-l-utilisateur

Dell-Photo-Printer-540-Guide-de-l-utilisateur

Dell-Streak-7-Francais-Manuel-de-l-utilisateur

Dell-Venue-Pro-Manuel-de-l-utilisateur

Dell-Imprimante-laser-personnelle-Dell-P1500-Manuel-du-proprietaire

Dell-PowerEdge-C5125-Manuel-du-proprietaire-du-materiel

Dell-Latitude-D630-Manuels

Dell-Vostro-400-Manuel-du-proprietaire-Mini-Tower

Dell-Systemes-Dell-PowerEdge-T100-Manuel-du-proprietaire

Dell-OptiPlex-9010-7010-compact-Manuel-du-proprietaire

Dell-PowerVault%20NX3200-Manuel-du-proprietaire

Dell-Inspiron-1200-et-2200-Manuel-de%20l-utilisateur

Dell-Vostro-1540-1550-Manuel-du-proprietaire

Dell-Inspiron-8600-Manuel-du-proprietaire

Dell-PowerVault-Baie-de-stockage-MD1120-Manuel-du-proprietaire

Dell-Dimension-E521-Manuel-du-proprietaire

Dell-Inspiron-9100-Manuel-du-proprietaire

Dell-Vostro-3360-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T300-Manuel-du-proprietaire

Dell-XPS-One-2710-manuel-d-utilisation

Dell-Inspiron-1150-Manuel-du-proprietaire

Dell-Latitude-E5530-Manuel-du-proprietaire

Dell-Inspiron-660-Manuel-du-proprietaire

Acceder-au-site-Dell

Dell-Manuel-du-proprietaire-des-Dell-Latitude-E6420-et-E6420-ATG-Francais

Dell-OptiPlex-9010-Tout-en-un-Manuel-du-proprietaire

Dell-Vostro-3560-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T110-Manuel-du-proprietaire

Dell-server-poweredge-m710-tech-guidebook_fr

Dell-Systemes-Dell-PowerEdge-R420-Manuel-du-proprietaire

Dell-Latitude-5420-E5420-E5420m-Manuel-de-l-utilisateur

Dell-Latitude-E6320-Manuel-de-l-utilisateur

Dell-Systemes-Dell-Inspiron-8200-Manuel-de-l-utilisateur-Francais

Dell-server-poweredge-r610-tech-guidebook_fr

Dell-server-poweredge-t710-technical-guide-book_fr

Dell-server-poweredge-m1000e-tech-guidebook_fr

Dell-server-poweredge-m610-tech-guidebook_fr

Dell-poweredge-r210-technical-guidebook-en_fr

Dell-MANUEL-ALIENWARE-M15x-MOBILE-Manuel-de-l-utilisateur

Dell-Axim-X51-X51v-Manuel-de-l-utilisateur

Dell-Beats-By-dr.dre-Manuel-et-Garantie

Dell-Dimension-3100C-Manuel-du-proprietaire

 

Dell-Precision-Workstation-T3600-Manuel-du-proprietaire

Dell-Vostro-200-Manuel-du-proprietaire-Slim-Tower

Dell-ALIENWARE-MANUEL-DE-L-ORDINATEUR-DE-BUREAU

Dell-OPENMANAGE-POWER-CENTER-1-1-Guide-d-utilisation

Dell-Vostro-360-Proprietaire-du-manuel

Dell-Dimension-3100C-Manuel-du-proprietaire

AlienwareArea-51Area-51ALX

Dell-Ordinateurs-de-Bureau-PC-Portables-Netbooks/AlienwareAurora-R3

AlienwareAurora-R4

lienwareAuroraAuroraALXAurora-R2

Chassis-RAID-Dell-PowerVault-MD3000i-Manuel-du-proprietaire

Dell-Axim-X50-Manuel-du-proprietaire

Dell-Axim-X51-X51v-Manuel-du-proprietaire

Dell-Baie-de-stockage-Dell-PowerVault-MD1000-Manuel-du-proprietaire

Dell-Boîtier-Dell-PowerEdge-M1000e-Manuel-du-proprietaire

Dell-Clavier-Axim-Manuel-du-proprietaire

Dell-Dimension-3100-E310-Manuel-du-proprietaire

Dell-Dimension-9200-Manuel-du-proprietaire

Dell-Dimension-E520-Manuel-du-proprietaire

Dell-Imprimante-laser-Dell-1100-Manuel-du-proprietaire

Dell-Imprimante-laser-de-groupe-de-travail-Dell-M5200-Manuel-du-proprietaire

Dell-Imprimante-laser-monochrome-Dell-5330dn-Mode-d-emploi

Dell-Imprimante-laser-multifonction-Dell-1600n-Manuel-du-proprietaire

Dell-Inspiron-13z-Manuel-du-proprietaire

Dell-Inspiron-17R-Manuel-du-proprietaire

Dell-Inspiron-530s-Manuel-d-utilisation

Dell-Inspiron-530s-Manuel-du-proprietaire

Dell-Inspiron-700m-Manuel-du-proprietaire

Dell-Inspiron-1100-Manuel-d-utilisation

Dell-Inspiron-1525-1526-Manuel-du-proprietaire

Dell-Inspiron-5100-et-5150-Manuel-d-utilisation

Dell-Inspiron-9300-Manuel-du-proprietaire

Dell-Inspiron-9400-E1705-Manuel-du-proprietaire

http://www.audentia-gestion.fr/Dell-Ordinateurs-de-Bureau-PC-Portables-Netbooks/Dell-Laser-Printer-1700-1700n-Manuel-du-proprietaire.htm

Dell-Laser-Printer-1710-1710n-Manuel-du-proprietaire

Dell-Laser-Printer-3100cn-manuel-du-proprietaire

Dell-Latitude-ST-Manuel-du-proprietaire

Dell-Latitude-XT3-Manuel-du-proprietaire

Dell-Liste-des-manuels-et-de-la-documentation-Dell

Dell-MANUEL-ALIENWARE-M11x-MOBILE-Manuel-du-proprietaire

Dell-MANUEL-ALIENWARE-M15x-MOBILE

Dell-MANUEL-D-ALIENWARE-M17x-MOBILE-francais

Dell-MANUEL-D-ALIENWARE-M17x-MOBILE

Dell-Manuel-d-utilisation-Dell-Inspiron-M5040-15-N5040-15-N5050

Dell-Manuel-d-utilisation-du-Dell-XPS-420

Dell-Manuel-de-l-Utilisateur-Dell-Latitude-E6220

Dell-Manuel-de-l-Utilisateur-Dell-Latitude-E6520

Dell-Manuel-de-l-utilisateur-Dell-Latitude-E6320

Dell-Manuel-de-maintenance-Dell-Inspiron-N5110

Dell-Manuel-du-proprietaire-Dell-Vostro-1500

Dell-Manuel-du-proprietaire-Dell-XPS-M1330

Dell-Manuel-du-proprietaire-des-Dell-Latitude-E6420-et-E6420-ATG

Dell-Manuel-du-proprietaire-du-Dell-Inspiron-1721

Dell-Manuel-du-proprietaire-du-Dell-XPS-M1730

Dell-Manuel-du-proprietaire-du-Dell-XPS-One

Dell-Matrices-de-stockage-Dell-PowerVault-MD3260i-Series-Guide-de-deploiement

Dell-Matrices-de-stockage-Dell-PowerVault-MD3660i-Series-Guide-de-deploiement

Dell-Photo-All-In-One-Printer-944-Manuel-du-proprietaire

Dell-Photo-All-In-One-Printer-964-Manuel-du-proprietaire

Dell-Photo-All-In-One-Printer%20942-Manuel-du-proprietaire

Dell-Photo-Printer-720-Manuel-du-proprietaire

Dell-PowerEdge-C8220-Manuel-du-proprietaire

Dell-PowerEdge-R620-Manuel-du-proprietaire

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Guide-de-l-administrateur

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Manuel-du-proprietaire

Dell-PowerVault-NX400-Guide-de-mise-en-route

Dell-Precision-Workstation-T7600-Manuel-du-proprietaire

Dell-Streak-7-Manuel-de-l-utilisateur

Dell-Streak-Manuel-d-utilisation

Dell-Systemes-Dell-Inspiron-4150-Manuel-de-l-utilisateur

Dell-Systemes-Dell-Inspiron-8200-Manuel-de-l-utilisateur

Dell-Systemes-Dell-PowerEdge-1950-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-M420-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R210-II-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R410-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R710-Manuel-du-proprietaire%20-Manuel-d-utilisation

Dell-Systemes-Dell-PowerEdge-T310-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T420-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-T620-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerVault-NX400-Manuel-du-proprietaire

Dell-Tout-en-un-Dell-Photo-924-Manuel-du-proprietaire

Dell-Vostro-360-Proprietaire-du-manuel

Dell-Vostro-3750-Manuel-du-proprietaire

Dell-Vostro-V131-Manuel-du-proprietaire

Dell-XP-M1530-Manuel-du-proprietaire

Dell-XPS-630i-Manuel-du-proprietair

Dell-moniteur-D1920-Manuel-du-proprietaire

DellDimension1100Series

Imprimante-Dell-Photo-All-In-One-Printer-922-Manuel-du-proprietaire

Imprimante-laser-de-groupe-de-travail-Dell-S2500-Manuel-du-proprietaire

Imprimante-personnelle-Dell-AIO-A960-Manuel-du-proprietaire

alienwareX51

Dell-Manuel-de-l-Utilisateur-Dell-Latitude-E6220

Dell-Systemes-Dell-PowerEdge-T420-Manuel-du-proprietaire

Dell-Systemes-Dell-Inspiron-4150-Manuel-de-l-utilisateur

Dell-Streak-Manuel-d-utilisation

Dell-Manuel-du-proprietaire-du-Dell-XPS-M1730

Dell-Photo-All-In-One-Printer-944-Manuel-du-proprietaire

Dell-Manuel-du-proprietaire-du-Dell-XPS-One

Dell-Clavier-Axim-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R410-Manuel-du-proprietaire

Dell-Manuel-d-utilisation-Dell-Inspiron-M5040-15-N5040-15-N5050

Dell-Manuel-de-maintenance-Dell-Inspiron-N5110

Dell-Inspiron-1100-Manuel-d-utilisation

Dell-Imprimante-laser-de-groupe-de-travail-Dell-M5200-Manuel-du-proprietaire

Dell-Photo-Printer-720-Manuel-du-proprietaire

Dell-Imprimante-laser-Dell-1100-Manuel-du-proprietaire

Dell-Manuel-du-proprietaire-Dell-Vostro-1500

Dell-XP-M1530-Manuel-du-proprietaire

Dell-Inspiron-530s-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-R710-Manuel-du-proprietaire-Manuel-d-utilisation

Dell-Inspiron-5100-et-5150-Manuel-d-utilisation

Dell-Manuel-de-l-Utilisateur-Dell-Latitude-E6520

Dell-MANUEL-D-ALIENWARE-M17x-MOBILE

Dell-Manuel-de-l-utilisateur-Dell-Latitude-E6320

Dell-Laser-Printer-3100cn-manuel-du-proprietaire

Dell-Inspiron-530s-Manuel-d-utilisation

Dell-Systemes-Dell-PowerEdge-1950-Manuel-du-proprietaire

Dell-Manuel-du-proprietaire-des-Dell-Latitude-E6420-et-E6420-ATG

Dell-Imprimante-laser-monochrome-Dell-5330dn-Mode-d-emploi

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Guide-de-l-administrateur

Dell-PowerVault-NX400-Guide-de-mise-en-route

Dell-Matrices-de-stockage-Dell-PowerVault-MD3260i-Series-Guide-de-deploiement

Dell-PowerEdge-C8220-Manuel-du-proprietaire

Dell-MANUEL-ALIENWARE-M11x-MOBILE-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerEdge-M420-Manuel-du-proprietaire

Dell-Systemes-Dell-PowerVault-NX400-Manuel-du-proprietaire

Dell-PowerVault-MD3260-3260i-3660i-3660f-3060e-Storage-Arrays-Manuel-du-proprietaire

Dell-Matrices-de-stockage-Dell-PowerVault-MD3660i-Series-Guide-de-deploiement

Dell-Laser-Printer-1700-1700n-Manuel-du-proprietaire

Dell-Inspiron-9400-E1705-Manuel-du-proprietaire

Dell-Tout-en-un-Dell-Photo-924-Manuel-du-proprietaire

Dell-Laser-Printer-1710-1710n-Manuel-du-proprietaire

Dell-Dimension-3100-E310-Manuel-du-proprietaire

Dell-Inspiron-1525-1526-Manuel-du-proprietaire

 Dell-PowerEdge-R815-..> 08-May-2013 10:52  4.3M  
 Dell-Inspiron-1521-M..> 08-May-2013 10:51  2.9M  
 Dell-PowerEdge-R900-..> 08-May-2013 10:50  3.1M  
 Dell-Vostro-270-Manu..> 08-May-2013 10:50  3.2M  
 Dell-XPS-630-Manuels..> 08-May-2013 10:49  3.6M  
 Dell-XPS-M1730-Manue..> 08-May-2013 10:49  3.9M  
 Dell-Vostro-200-Manu..> 08-May-2013 10:48  4.5M  
 Dell-Vostro-410-Manu..> 08-May-2013 10:48  4.1M  
 Dell-Vostro-1700-Man..> 08-May-2013 10:47  4.8M  
 Dell-Inspiron-m301z-..> 08-May-2013 10:47  4.8M  
 Dell-Studio-Slim-Man..> 08-May-2013 10:45  5.1M  
 Dell-Windows-8-Manue..> 08-May-2013 10:45  5.1M  
 Dell-PowerEdge-R620-..> 08-May-2013 08:46  4.1M  
 Dell-PowerEdge-R200-..> 08-May-2013 08:46  2.6M  
 Dell-Inspiron-640M-M..> 08-May-2013 08:46  3.7M  
 Dell-Inspiron-600m-M..> 08-May-2013 08:45  2.6M  
 Dell-Studio-Desktop-..> 08-May-2013 08:44  2.7M  
 Dell-Vostro-1000-Man..> 08-May-2013 08:44  2.7M  
 Dell-Inspiron-15-Int..> 08-May-2013 08:44  3.0M  
 Dell-Alienware-Area-..> 08-May-2013 08:43  3.1M  
 Dell-DR4000-Manuels.htm 08-May-2013 08:43  3.4M  
 Dell-Alienware-M15x-..> 08-May-2013 08:42  3.3M  
 Dell-Latitude-XT2-Ma..> 08-May-2013 08:42  3.5M  
 Dell-Latitude-E5520-..> 08-May-2013 08:41  3.5M  
 Dell-OptiPlex-745-Ma..> 08-May-2013 08:40  3.9M  
 Dell-Inspiron-1525-M..> 08-May-2013 08:40  3.9M  
 Dell-Inspiron-One-23..> 08-May-2013 08:39  4.2M  
 Dell-Inspiron-One-23..> 08-May-2013 08:39  2.8M  
 Dell-Inspiron-510m-M..> 08-May-2013 08:38  3.2M  
 Dell-Inspiron-Duo-Ma..> 08-May-2013 08:38  3.0M  
 Dell-Vostro-1550-Man..> 08-May-2013 08:37  3.4M  
 Dell-Precision-T5600..> 08-May-2013 08:37  3.3M  
 Dell-Dimension-8300-..> 07-May-2013 22:03  2.5M  
 Dell-Latitude-Cpi-Ma..> 07-May-2013 22:01  3.2M  
 Dell-Alienware-Area-..> 07-May-2013 22:01  3.2M  
 Dell-Latitude-D620-M..> 07-May-2013 22:00  2.3M  
 Dell-PowerEdge-1950-..> 07-May-2013 22:00  2.2M  
 Dell-Precision-T5600..> 07-May-2013 21:30  3.1M  
 Dell-PowerEdge-R720x..> 07-May-2013 21:26  3.1M  
 Dell-Inspiron-500m-M..> 07-May-2013 21:26  2.8M  
 Dell-PowerEdge-R815-..> 07-May-2013 21:25  2.8M  
 Dell-Alienware-M15x-..> 07-May-2013 21:25  2.8M  
 Dell-Vostro-3450-Man..> 07-May-2013 21:24  2.8M  
 Dell-PowerEdge-R610-..> 07-May-2013 21:24  2.9M  
 Dell-Vostro-3750-Man..> 07-May-2013 21:23  3.0M  
 Dell-Studio-1555-15-..> 07-May-2013 21:23  3.1M  
 Dell-Manuel-de-maint..> 07-May-2013 21:22  3.0M  
 Dell-Latitude-E6420-..> 07-May-2013 21:22  3.1M  
 Dell-Inspiron-1520-M..> 07-May-2013 21:21  2.0M  
 Dell-Aztech-MDP3900-..> 07-May-2013 21:21  2.0M  
 Dell-PowerEdge-M905-..> 07-May-2013 21:21  2.0M  
 Dell-PowerEdge-400SC..> 07-May-2013 21:21  2.1M  
 Dell-Precision-M4500..> 07-May-2013 21:20  2.2M  
 Dell-Vizioncore-Manu..> 07-May-2013 21:20  2.1M  
 Dell-Inspiron-1520-2..> 07-May-2013 21:19  2.5M  
 Dell-Guide-Utilisate..> 07-May-2013 21:19  2.4M  
 Dell-PowerEdge-R510-..> 07-May-2013 21:18  2.7M  
 Dell-Manuel-d-Utilis..> 07-May-2013 21:18  2.4M  
 Dell-PowerEdge-300-M..> 06-May-2013 19:33  4.7M  
 Dell-Lifecycle-Contr..> 06-May-2013 19:32  4.3M  
 Dell-PowerVault-110T..> 06-May-2013 19:31  4.4M  
 Dell-Inspiron-620-Ma..> 06-May-2013 19:10  3.2M  
 Dell-Dimension-5100-..> 06-May-2013 19:10  3.4M  
 Dell-Manuels-et-docu..> 06-May-2013 19:09  3.7M  
 Dell-Manuels-et-docu..> 06-May-2013 19:09  3.5M  
 Dell-1130-Dell-1130n..> 06-May-2013 18:42  3.1M  
 Code-Promo-Dell.htm     04-Feb-2013 09:17  1.0M  
 Sony-NV-U83N-Manuels..> 02-Feb-2013 09:00  5.0M  
 Dell-Sansa-Clip-MP3-..> 27-Nov-2012 09:15  3.0M  
 Dell-TSi-500-TSi-400..> 27-Nov-2012 09:15  1.0M  
 Dell-Vostro-3360-Man..> 27-Nov-2012 09:10  2.6M  
 Dell-Inspiron-5100-e..> 27-Nov-2012 09:09  2.8M  
 Dell-Systemes-Dell-P..> 27-Nov-2012 09:09  3.1M  
 Dell-1815dn-Manuel ..> 27-Nov-2012 09:09  3.5M  
 Dell-PowerVault-MD32..> 27-Nov-2012 09:08  1.7M  
 Dell-Multifunktionsp..> 27-Nov-2012 09:07  2.4M  
 Dell-PowerVault-MD32..> 27-Nov-2012 09:07  2.0M  
 Dell-Inspiron-1150-M..> 27-Nov-2012 09:07  2.8M  
 Dell-PowerEdge-C8220..> 27-Nov-2012 09:07  2.6M  
 Dell-Systemes-Dell-P..> 27-Nov-2012 09:06  2.5M  
 Dell-PowerVault-MD32..> 27-Nov-2012 09:06  1.8M  
 Dell-Systemes-Dell-P..> 27-Nov-2012 07:42  3.0M  
 Dell-Matrices-de-sto..> 27-Nov-2012 07:40  3.5M  
 Dell-Systemes-Dell-D..> 27-Nov-2012 07:40  3.8M  
 Dell-Console-de-gest..> 27-Nov-2012 07:40  3.9M  
 Dell-Logiciel-de-ges..> 27-Nov-2012 07:26  2.9M  
 Dell-MANUEL-ALIENWAR..> 27-Nov-2012 07:20  2.6M  
 Dell-Axim-X51-X51v-M..> 27-Nov-2012 07:18  2.5M  
 Dell-Dimension-9150-..> 27-Nov-2012 07:07  2.3M  
 Lien-Manuels-Utilisa..> 19-Nov-2012 07:12   92K  
 Dell-XPS-600-francai..> 19-Nov-2012 06:29  2.1M  
 Dell-XPS-430-francai..> 19-Nov-2012 06:24  1.8M  
 Dell-XPS-420-francai..> 18-Nov-2012 21:25  3.8M  
 Dell-XPS-410-Anglais..> 18-Nov-2012 21:25  3.4M  
 Dell-Dimension-9200C..> 18-Nov-2012 21:03  3.1M  
 Dell-Dimension-1000-..> 18-Nov-2012 20:57  2.9M  
 Dell-Alienware-Auror..> 18-Nov-2012 20:49  2.3M  
 Dell-Alienware-Area-..> 18-Nov-2012 20:45  1.8M  
 Dell-Alienware-Area-..> 18-Nov-2012 20:44  1.9M  
 Dell-Alienware-Area-..> 18-Nov-2012 20:44  1.9M  
 Dell-Alienware-Auror..> 18-Nov-2012 20:44  1.9M  
 Dell-Alienware-Auror..> 18-Nov-2012 20:43  2.3M  
 Dell-Alienware-Auror..> 18-Nov-2012 20:43  2.2M  
 Dell-OpenManage-Remo..> 14-Nov-2012 22:12  4.9M  
 Dell-OpenManage-Serv..> 14-Nov-2012 22:12  5.0M  
 Dell-Media-Center-Gu..> 14-Nov-2012 22:11  1.6M  
 Dell-Systemes-Dell-P..> 14-Nov-2012 21:42  3.2M  
 Dell-E-Legacy-Extend..> 14-Nov-2012 21:40  2.8M  
 Dell-Dimension-XPS-M..> 14-Nov-2012 21:39  3.0M  
 Dell-Adaptateurs-Del..> 14-Nov-2012 21:39  3.1M  
 Dell-Axim-X3-Guide-d..> 14-Nov-2012 21:38  3.4M  
 Dell-Guide-d-utilisa..> 14-Nov-2012 21:38  4.1M  
 Dell-OpenManage-Serv..> 14-Nov-2012 21:38  3.7M  
 Dell-Latitude-D531-G..> 14-Nov-2012 21:36  4.7M  
 Dell-Latitude-D430-G..> 14-Nov-2012 21:36  4.4M  
 Dell-Inspiron-1501-M..> 14-Nov-2012 21:06  5.1M  
 Dell-Systemes-Dell-D..> 14-Nov-2012 21:05  2.6M  
 Dell-Guide-d-utilisa..> 14-Nov-2012 21:05  3.6M  
 Dell-PowerEdge-T110-..> 14-Nov-2012 21:04  3.6M  
 Dell-Guide-d-utilisa..> 14-Nov-2012 21:03  4.1M  
 Dell-XPS-M1710-Manue..> 14-Nov-2012 21:03  4.4M  
 Dell-Ordinateurs-por..> 14-Nov-2012 21:02  4.8M  
 Dell-Studio-GUIDE-DE..> 14-Nov-2012 21:01  5.5M  
 Dell-Inspiron-1420-M..> 14-Nov-2012 21:01  5.4M  
 Dell-Systemes-Dell-P..> 14-Nov-2012 21:00  2.4M  
 Dell-Latitude-D830-G..> 14-Nov-2012 20:59  2.2M  
 Dell-Systemes-Dell-P..> 14-Nov-2012 20:59  2.4M  
 Dell-Dimension-1100-..> 14-Nov-2012 12:08  3.6M  
 Dell-Inspiron-One-23..> 14-Nov-2012 12:08  3.7M  
 Dell-Manuel-de-maint..> 14-Nov-2012 12:07  3.8M  
 Dell-Photo-All-in-On..> 14-Nov-2012 12:06  4.0M  
 Dell-Carte-de-gestio..> 14-Nov-2012 12:05  4.0M  
 Dell-Systemes-Dell-P..> 14-Nov-2012 12:05  4.3M  
 Dell-XPS-M1710-Manue..> 13-Nov-2012 09:56  3.4M  
 Dell-Inspiron-6400-E..> 13-Nov-2012 08:20  2.8M  
 Dell-Systemes-Dell-P..> 13-Nov-2012 08:19  3.4M  
 Dell-Inspiron-1300-B..> 13-Nov-2012 08:19  3.1M  
 Dell-OptiPlex-9010-7..> 13-Nov-2012 08:18  1.7M  
 Dell-Laser-Printer-5..> 13-Nov-2012 08:18  1.9M  
 Dell-XPS-710-H2C-Man..> 13-Nov-2012 08:18  2.5M  
 Dell-Inspiron-1520-M..> 13-Nov-2012 08:17  2.9M  
 Dell-Inspiron-1721-M..> 13-Nov-2012 08:17  3.2M  
 Dell-Inspiron-One-23..> 13-Nov-2012 08:16  3.3M  
 Dell-XPS-M2010-Manue..> 13-Nov-2012 08:16  3.7M  
 Dell-Inspiron-1000-M..> 13-Nov-2012 08:15  3.9M  
 Dell-Inspiron-8500-G..> 13-Nov-2012 08:14  4.1M  
 Dell-Inspiron-640M-E..> 13-Nov-2012 08:13  4.5M  
 Dell-Axim-X50-Manuel..> 13-Nov-2012 08:12  4.7M  
 Dell-Inspiron-300m-G..> 13-Nov-2012 08:12  2.0M  
 Dell-Inspiron-XPS-Ge..> 13-Nov-2012 08:11  2.2M  
 Dell-Inspiron-5160-M..> 13-Nov-2012 08:11  2.4M  
 Dell-Inspiron-8600-G..> 13-Nov-2012 08:11  2.7M  
 Dell-PowerVault-DL20..> 13-Nov-2012 08:11  2.9M  
 Dell-Imprimante-pers..> 13-Nov-2012 08:10  3.0M  
 Dell-Vostro-410-Guid..> 12-Nov-2012 17:26  2.4M  
 Dell-Manuel-de-l-Uti..> 12-Nov-2012 17:07  2.6M  
 Dell-Dimension-serie..> 12-Nov-2012 17:07  1.9M  
 Dell-xps-13-l321x_se..> 12-Nov-2012 17:00  1.9M  
 Dell-XPS-13-Manuel-d..> 12-Nov-2012 16:59  1.9M  
 Dell-Manuel-de-maint..> 12-Nov-2012 16:59  2.1M  
 Dell-Inspiron-2600-e..> 12-Nov-2012 16:59  2.3M  
 Dell-PowerVault-NX33..> 12-Nov-2012 16:58  2.6M  
 Dell-Pave-Tactile-Sa..> 12-Nov-2012 16:58  2.6M  
 Dell-poweredge-r520-..> 12-Nov-2012 16:58  2.7M  
 Dell-Inspiron-5423-O..> 12-Nov-2012 16:57  2.7M  
 Dell-Inspiron-3500-P..> 12-Nov-2012 16:57  2.7M  
 Dell-Inspiron-3000-S..> 12-Nov-2012 16:56  2.7M  
 Dell-Vostro-270-Owne..> 12-Nov-2012 16:56  2.8M  
 Dell-server-poweredg..> 12-Nov-2012 16:56  2.9M  
 Dell-PowerEdge-C6220..> 12-Nov-2012 16:55  3.2M  
 Dell-2145cn-Impriman..> 12-Nov-2012 16:55  3.6M  
 Dell-Dimension-Serie..> 12-Nov-2012 16:54  3.8M  
 Dell-PERC-6-i-PERC-6..> 12-Nov-2012 16:53  4.1M  
 Dell-Configuration-d..> 12-Nov-2012 16:53  4.1M  
 Dell-MANUEL-ALIENWAR..> 12-Nov-2012 16:51  2.1M  
 Dell-ALIENWARE-M18x-..> 12-Nov-2012 16:51  2.2M  
 Dell-MANUEL-DE-L-ORD..> 12-Nov-2012 16:51  2.3M  
 Dell-Carte-de-Gestio..> 06-Nov-2012 18:45  2.0M  
 Dell-Studio-XPS-1640..> 06-Nov-2012 18:40  2.7M  
 Dell-Studio-XPS-GUID..> 06-Nov-2012 18:40  2.3M  
 Dell-Storage-Center-..> 06-Nov-2012 11:43  3.7M  
 Dell-PowerEdge-T300-..> 06-Nov-2012 07:33  2.3M  
 Dell-Manual-del-prop..> 06-Nov-2012 07:33  2.4M  
 Dell-Manual-del-prop..> 06-Nov-2012 07:32  2.5M  
 Dell-PowerEdge-Syste..> 06-Nov-2012 07:32  2.7M  
 Dell-PowerEdge-R710-..> 06-Nov-2012 07:31  3.0M  
 Dell-S2440L-Monitor-..> 06-Nov-2012 07:31  3.0M  
 Dell-P1913-P1913S-P2..> 06-Nov-2012 07:31  2.0M  
 Dell-U2713HM-Flat-Pa..> 06-Nov-2012 07:30  2.0M  
 Dell-U2713HM-Flat-Pa..> 06-Nov-2012 07:30  2.0M  
 Dell-E1913S-E1913-E2..> 06-Nov-2012 07:29  2.1M  
 Dell-Latitude-ST-Kul..> 06-Nov-2012 07:29  2.1M  
 Dell-PowerEdge-R310-..> 06-Nov-2012 07:29  2.4M  
 Dell-Storage-Center-..> 06-Nov-2012 07:29  2.7M  
 Dell-Latitude-XT3-Ow..> 06-Nov-2012 07:28  1.7M  
 Dell-Manuel-de-maint..> 06-Nov-2012 07:28  1.8M  
 Dell-Vostro-3450-Man..> 06-Nov-2012 07:27  1.9M  
 Dell-Inspiron-14z-N4..> 06-Nov-2012 07:27  2.0M  
 Dell-Module-de-venti..> 06-Nov-2012 07:27  2.0M  
 Dell-Matrices-de-sto..> 06-Nov-2012 07:26  2.6M  
 Dell-Points-d-acces-..> 06-Nov-2012 07:26  2.0M  
 Dell-Guide-de-l-util..> 05-Nov-2012 18:31  4.2M  
 Dell-Boitiers-de-sto..> 05-Nov-2012 18:14  1.4M  
 Dell-Studio-One-GUID..> 05-Nov-2012 18:14  1.5M  
 Dell-Vostro-1310-151..> 05-Nov-2012 18:14  1.6M  
 Dell-Systemes-Dell-P..> 05-Nov-2012 18:13  1.9M  
 Dell-Modules-optique..> 05-Nov-2012 18:13  1.9M  
 Dell-PowerEdge-R900-..> 05-Nov-2012 18:13  2.2M  
 Dell-Latitude-E6520-..> 05-Nov-2012 18:13  2.0M  
 Dell-PowerEdge-2900-..> 05-Nov-2012 18:12  2.4M  
 Dell-Point-d-acces-D..> 05-Nov-2012 18:12  2.5M  
 Dell-B1260dn-Mode-d-..> 05-Nov-2012 18:11  2.7M  
 Dell-B1160-Dell-B116..> 05-Nov-2012 18:11  2.9M  
 Dell-OpenManage-Serv..> 05-Nov-2012 18:10  3.3M  
 Dell-PowerEdge-T310-..> 05-Nov-2012 18:10  3.6M  
 Dell-PowerEdge-R410-..> 05-Nov-2012 18:09  3.8M  
 Dell-Inspiron-Guide-..> 05-Nov-2012 18:08  1.3M  
 Dell-Guide-de-soluti..> 05-Nov-2012 17:29  3.8M  
 Adaptateurs-Brocade-..> 05-Nov-2012 15:05  3.6M  
 Dell-PowerEdge-R415-..> 05-Nov-2012 15:01  1.7M  
 Dell-PowerVault-MD-S..> 05-Nov-2012 15:01  1.7M  
 Dell-PowerEdge-2950-..> 05-Nov-2012 15:01  1.9M  
 Dell-PowerEdge-R710-..> 05-Nov-2012 15:00  1.9M  
 Dell-Server-PRO-Mana..> 05-Nov-2012 15:00  2.0M  
 Dell-PowerVault-NX20..> 05-Nov-2012 15:00  2.0M  
 Dell-PowerVault-MD11..> 05-Nov-2012 15:00  2.0M  
 Dell-SAS-RAID-Storag..> 05-Nov-2012 14:59  2.2M  
 Dell-Imprimante-lase..> 05-Nov-2012 14:59  2.2M  
 IOGEAR-Guide-d-insta..> 05-Nov-2012 14:58  2.3M  
 Dell-MANUEL-ALIENWAR..> 05-Nov-2012 14:58  2.4M  
 Dell-Guide-d-install..> 05-Nov-2012 14:58  2.8M  
 Dell-Inspiron-600m-M..> 05-Nov-2012 14:57  2.6M  
 Planification-du-dep..> 05-Nov-2012 14:57  3.1M  
 Dell-Vizioncore-vRep..> 05-Nov-2012 14:57  3.0M  
 Dell-Server-Deployme..> 05-Nov-2012 14:56  3.7M  
 Dell-Latitude-XT2-XF..> 05-Nov-2012 14:54  3.7M  
 Dell-Deploiement-de-..> 05-Nov-2012 12:15  2.6M  
 Dell-Setting-up-Your..> 05-Nov-2012 12:15  2.6M  
 Dell-PowerQuest-Data..> 05-Nov-2012 12:15  2.6M  
 Dell-Controleurs-Del..> 05-Nov-2012 12:14  2.8M  
 Dell-Systemes-Dell-P..> 05-Nov-2012 12:14  2.9M  
 Dell-Guide-de-demarr..> 05-Nov-2012 12:13  2.9M  
 Dell-Guide-de-config..> 05-Nov-2012 12:13  3.0M  
 Dell-Guide-d-utilisa..> 05-Nov-2012 12:12  3.0M  
 Dell-1250c-Color-Pri..> 05-Nov-2012 12:12  3.0M  
 Dell-XPS-600-Manuel-..> 05-Nov-2012 12:11  3.3M  
 Dell-Imprimante-lase..> 05-Nov-2012 12:11  3.4M  
 Dell-Systemes-Dell-P..> 05-Nov-2012 12:10  3.8M  
 Dell-Photo-All-In-On..> 05-Nov-2012 12:10  3.6M  
 Dell-Studio-XPS-Setu..> 05-Nov-2012 12:09  1.3M  
 Dell-XPS-13-Kullanı..> 05-Nov-2012 12:09  1.4M  
 Dell-XPS-13-Chinois-..> 05-Nov-2012 12:08  1.6M  
 Dell-XPS-13-Arabe-Ma..> 05-Nov-2012 12:08  1.5M  
 Dell-Setting-up-Your..> 05-Nov-2012 10:08  1.9M  
 Dell-Setting-up-Your..> 05-Nov-2012 10:08  1.9M  
 Dell-Vizioncore-vCon..> 05-Nov-2012 10:08  2.4M  
 Dell-Cartes-controle..> 05-Nov-2012 10:08  2.0M  
 Dell-Guide-de-l-util..> 05-Nov-2012 09:06  1.9M  
 Dell-Bandotheques-De..> 05-Nov-2012 09:03  2.1M  
 Dell-S320-S320wi-Pro..> 05-Nov-2012 09:02  1.7M  
 Dell-PowerEdge-RAID-..> 05-Nov-2012 09:02  2.4M  
 Dell-Matrices-de-sto..> 05-Nov-2012 09:02  2.2M  
 Dell-Vizioncore-vRan..> 05-Nov-2012 09:01  2.6M  
 Dell-Cartes-d-extens..> 05-Nov-2012 09:01  2.6M  
 Dell-Guide-technique..> 05-Nov-2012 09:00  3.2M  
 Dell-Onduleur-en-Bai..> 05-Nov-2012 09:00  2.7M  
 Dell-Matrices-de-sto..> 05-Nov-2012 08:59  3.7M  
 Dell-Setting-up-Your..> 05-Nov-2012 08:59  3.2M  
 Dell-Systemes-Dell-P..> 05-Nov-2012 08:58  4.2M  
 Dell-Guide-d-utilisa..> 05-Nov-2012 08:58  4.1M  
 Dell-M5200-Carte-de-..> 05-Nov-2012 07:58  1.6M  
 Dell-XPS-L412z-Manue..> 05-Nov-2012 07:38  2.0M  
 Dell-XPS-GUIDE-DE-CO..> 05-Nov-2012 07:38  2.1M  
 Dell-Studio-XPS-8100..> 05-Nov-2012 07:38  2.1M  
 Dell-XPS-One-GUIDE-D..> 05-Nov-2012 07:37  2.2M  
 Dell-INSPIRON-Setup-..> 05-Nov-2012 07:32  2.3M  
 Dell-Inspiron-14R-M4..> 05-Nov-2012 07:32  2.4M  
 Dell-XPS-M1210-Owner..> 05-Nov-2012 07:32  2.7M  
 Dell-Inspiron-6000-M..> 05-Nov-2012 07:31  2.9M  
 Dell-Guide-de-l-util..> 05-Nov-2012 07:31  3.5M  
 Dell-PERC-6-i-PERC-6..> 05-Nov-2012 07:31  3.8M  
 Dell-Adaptateurs-Del..> 05-Nov-2012 07:30  3.9M  
 Dell-Guide-d-utilisa..> 05-Nov-2012 07:29  4.2M  
 Dell-DX-Object-Stora..> 04-Nov-2012 11:04  2.8M  
 Dell-PowerEdge-T620-..> 04-Nov-2012 11:04  2.8M  
 Dell-Guide-d-install..> 04-Nov-2012 11:03  2.9M  
 Dell-Dimension-XPS-G..> 04-Nov-2012 11:03  3.1M  
 Dell-Latitude-E6500-..> 04-Nov-2012 11:02  3.3M  
 Dell-PowerEdge-Expan..> 04-Nov-2012 11:02  3.5M  
 Dell-Matrices-de-sto..> 04-Nov-2012 11:01  3.6M  
 Dell-Matrices-de-sto..> 04-Nov-2012 11:01  3.7M  
 Dell-PowerVault-Data..> 04-Nov-2012 11:00  2.7M  
 Dell-PowerVault-Encr..> 04-Nov-2012 10:41  2.5M  
 Dell-APC-Smart-UPS-A..> 04-Nov-2012 10:41  2.6M  
 Dell-PowerVault-Data..> 04-Nov-2012 10:41  2.6M  
 Dell-PowerVault-Data..> 03-Nov-2012 21:47  2.0M  
 Dell-EqualLogic-Stor..> 03-Nov-2012 21:47  2.1M  
 Dell-Latitude-E4300-..> 03-Nov-2012 21:46  2.3M  
 Dell-Matrices-de-sto..> 03-Nov-2012 21:46  2.2M  
 Dell-OptiPlex-755-Gu..> 03-Nov-2012 21:12  5.7M  
 Dell-PowerEdge-C8000..> 03-Nov-2012 18:23  2.1M  
 Dell-PowerEdge-T420-..> 03-Nov-2012 18:19  2.1M  
 Dell-Commutateur-de-..> 03-Nov-2012 18:19  2.3M  
 Dell-INSPIRON-GUIDE-..> 03-Nov-2012 18:16  2.4M  
 Dell-Systemes-Dell-P..> 03-Nov-2012 18:15  2.4M  
 Dell-XPS 15-Manuel-d..> 03-Nov-2012 18:15  2.4M  
 Dell-PowerVault-DL-B..> 03-Nov-2012 18:12  2.6M  
 Dell-Laser-MFP-Dell-..> 03-Nov-2012 18:12  3.2M  
 Dell-Controleurs-RAI..> 03-Nov-2012 18:11  3.4M  
 Dell-PowerEdge-Expre..> 03-Nov-2012 18:11  1.7M  
 Dell-FluidFS-NAS-Sol..> 03-Nov-2012 18:10  2.1M  
 Dell-Projecteur-Dell..> 03-Nov-2012 18:10  1.8M  
 Dell-Projecteur-7700..> 03-Nov-2012 18:09  2.2M  
 Dell-Management-Plug..> 03-Nov-2012 18:09  2.5M  
 Dell-Integrated-Dell..> 03-Nov-2012 18:09  3.1M  
 Dell-Systemes-Dell-P..> 03-Nov-2012 18:08  2.6M  
 Dell-Systeme-Dell-DR..> 03-Nov-2012 18:08  3.6M  
 Dell-OpenManage-Serv..> 03-Nov-2012 18:07  3.3M  
 Dell-Utilitaires-de-..> 03-Nov-2012 18:06  3.8M  
 Dell-Systemes-Dell-P..> 03-Nov-2012 18:06  3.9M  
 Dell-PowerEdge-C410x..> 03-Nov-2012 18:05  4.0M  
 Dell-Systemes-Dell-P..> 03-Nov-2012 18:05  4.3M  
 Dell-Manuel-du-propr..> 03-Nov-2012 18:04  4.6M  
 Dell-Set-Up-Your-Com..> 03-Nov-2012 18:04  4.6M  
 Dell-Latitude-E5400-..> 03-Nov-2012 18:02  4.7M  
 Dell-Matrices-de-sto..> 03-Nov-2012 18:02  4.9M  
 Dell-Dimension-Serie..> 03-Nov-2012 18:01  5.1M  
 Dell-INSPIRON-GUIDE-..> 03-Nov-2012 11:09  3.0M  
 Dell-Moniteur-a-Dell..> 03-Nov-2012 11:09  3.1M  
 Dell-Systems-Service..> 03-Nov-2012 11:08  3.1M  
 Dell-Guide-de-l-util..> 03-Nov-2012 11:07  3.1M  
 Dell-Moniteur-a-Dell..> 03-Nov-2012 11:07  3.2M  
 Dell-Moniteur-a-ecra..> 03-Nov-2012 11:06  3.2M  
 Dell-PowerEdge-C410x..> 03-Nov-2012 11:06  3.3M  
 Dell-Matrices-de-sto..> 03-Nov-2012 11:05  3.4M  
 Dell-Precision-M4400..> 03-Nov-2012 11:05  1.5M  
 Dell-Systemes-Dell-P..> 03-Nov-2012 11:04  1.9M  
 Dell-PowerEdge-R320-..> 03-Nov-2012 11:04  1.5M  
 Dell-PowerEdge-R720-..> 03-Nov-2012 11:04  2.0M  
 Dell-Update-Packages..> 03-Nov-2012 11:04  1.9M  
 Dell-Micrologiciel-D..> 03-Nov-2012 08:46  2.9M  
 Dell-FluidFS-NAS-Sol..> 03-Nov-2012 08:45  3.0M  
 Dell-PowerEdge-RAID-..> 03-Nov-2012 08:44  3.2M  
 Dell-Systemes-Dell-P..> 03-Nov-2012 08:44  3.0M  
 Dell-Inspiron-15R-Ma..> 03-Nov-2012 08:43  3.5M  
 Dell-OpenManage-Serv..> 03-Nov-2012 08:43  3.4M  
 Dell-PowerEdge-M1000..> 03-Nov-2012 08:42  3.7M  
 Dell-OpenManage-Serv..> 03-Nov-2012 08:42  3.7M  
 Dell-PowerEdge-C8000..> 03-Nov-2012 08:30  2.3M  
 Dell-PowerEdge-R820-..> 03-Nov-2012 08:30  2.0M  
 Dell-PowerEdge-C8220..> 03-Nov-2012 08:29  2.5M  
 Dell-PowerEdge-R420-..> 03-Nov-2012 08:29  2.5M  
 Dell-Systemes-Dell-D..> 03-Nov-2012 08:28  2.8M  
 Dell-Precision-Works..> 03-Nov-2012 08:28  2.6M  
 Dell-PowerEdge-T320-..> 03-Nov-2012 08:27  2.8M  
 Dell-Systemes-Dell-D..> 03-Nov-2012 08:27  2.8M  
 Dell-Guide-de-l-util..> 03-Nov-2012 08:27  3.0M  
 Dell-Latitude-E6420-..> 03-Nov-2012 08:27  3.0M  
 Dell-Systeme-Dell-Po..> 02-Nov-2012 18:07  3.4M  
 Dell-Vostro-470-Manu..> 02-Nov-2012 18:07  3.5M  
 Dell-PowerVault-MD32..> 02-Nov-2012 18:07  3.4M  
 Dell-XPS-14-Manuel-d..> 02-Nov-2012 17:36  3.1M  
 Dell-Inspiron-One-20..> 02-Nov-2012 17:23  3.0M  
 Dell-Matrices-de-sto..> 02-Nov-2012 17:22  3.0M  
 Dell-PowerConnect-55..> 02-Nov-2012 17:22  3.8M  
 Dell-PowerVault-NX33..> 02-Nov-2012 17:21  1.7M  
 Dell-Upgrading-to-Ba..> 02-Nov-2012 17:21  1.4M  
 Dell-Projecteur-Dell..> 02-Nov-2012 17:20  1.8M  
 Dell-Vostro-470-Owne..> 02-Nov-2012 17:20  1.7M  
 Dell-Inspiron-14R-Ma..> 02-Nov-2012 17:20  2.2M  
 Dell-Systeme-Dell-Po..> 02-Nov-2012 17:20  2.1M  
 Dell-Vostro-270-Manu..> 02-Nov-2012 17:19  2.6M  
 Dell-PowerEdge-R820-..> 02-Nov-2012 17:19  2.5M  
 Dell-Inspiron-660s-M..> 02-Nov-2012 17:18  2.7M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 17:18  2.8M  
 Dell-Inspiron-17R-Ma..> 02-Nov-2012 17:17  2.9M  
 Dell-Micrologiciel-D..> 02-Nov-2012 16:35  2.9M  
 Dell-PowerEdge-R720-..> 02-Nov-2012 16:34  2.8M  
 Dell-PowerEdge-R815-..> 02-Nov-2012 16:34  3.1M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 16:33  3.5M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 16:33  1.9M  
 Dell-PowerEdge-R905-..> 02-Nov-2012 16:32  2.2M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 16:32  2.8M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 16:32  2.5M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 16:31  2.9M  
 Dell-HBA-SAS-Dell-Po..> 02-Nov-2012 16:31  2.9M  
 Dell-XPS-13-Owner-s-..> 02-Nov-2012 16:30  3.0M  
 Dell-Alienware-M17x-..> 02-Nov-2012 16:30  3.1M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 16:29  3.4M  
 Dell-Emplacement-des..> 02-Nov-2012 16:29  3.1M  
 Dell-ALIENWARE-M17x-..> 02-Nov-2012 16:28  3.5M  
 Dell-Alienware-X51-O..> 02-Nov-2012 16:28  3.4M  
 Dell-Moniteur-a-Dell..> 02-Nov-2012 16:27  3.6M  
 Dell-Guide-de-l-Util..> 02-Nov-2012 16:27  3.5M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 11:45  2.0M  
 Dell-FluidFS-NAS-Sol..> 02-Nov-2012 11:24  1.7M  
 Dell-Latitude-ST-Man..> 02-Nov-2012 11:23  3.8M  
 Dell-OptiPlex-360-Gu..> 02-Nov-2012 11:23  3.4M  
 Dell-Adaptateurs-Bro..> 02-Nov-2012 11:22  2.8M  
 Dell-XPS-13-Manuel-d..> 02-Nov-2012 11:22  2.9M  
 Dell-Guide-de-l-util..> 02-Nov-2012 11:21  3.2M  
 Dell-Solutions-NAS-D..> 02-Nov-2012 11:21  3.2M  
 Dell-OpenManage-Serv..> 02-Nov-2012 11:20  3.7M  
 Dell-Lifecycle-Contr..> 02-Nov-2012 11:20  3.5M  
 Dell-PowerEdge-RAID-..> 02-Nov-2012 10:08  2.4M  
 Dell-XPS-430-Guide-d..> 02-Nov-2012 10:08  2.4M  
 Dell-Imprimantes-las..> 02-Nov-2012 10:07  2.4M  
 Dell-Imprimantes-las..> 02-Nov-2012 10:07  2.4M  
 Dell-Guide-d-utilisa..> 02-Nov-2012 10:06  2.5M  
 Dell-Guide-d-utilisa..> 02-Nov-2012 10:06  2.4M  
 Dell-Vostro-1310-151..> 02-Nov-2012 10:06  2.6M  
 Dell-1235cn-Impriman..> 02-Nov-2012 10:06  3.0M  
 Dell-Guide-d-utilisa..> 02-Nov-2012 10:05  3.4M  
 Dell-2130cn-IMPRIMAN..> 02-Nov-2012 10:05  3.0M  
 Dell-Imprimante-pers..> 02-Nov-2012 09:44  2.7M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 09:44  3.1M  
 Dell-Imprimante-lase..> 02-Nov-2012 09:44  2.9M  
 Dell-Guide d-install..> 02-Nov-2012 09:43  2.1M  
 Dell-PowerEdge-R810-..> 02-Nov-2012 09:43  2.0M  
 Dell-Inspiron-660s-M..> 02-Nov-2012 09:42  2.5M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 09:42  2.4M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 09:41  2.8M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 09:41  3.1M  
 Dell-Systemes-Dell-P..> 02-Nov-2012 09:40  3.6M  
 Dell-Inspiron-600m-M..> 02-Nov-2012 09:40  3.3M  
 Dell-3D-VISION-MANUE..> 02-Nov-2012 09:39  1.8M  
 Dell-Manuel-de-maint..> 02-Nov-2012 09:39  1.7M  
 Dell-Manuel-d-utilis..> 02-Nov-2012 09:38  1.9M  
 Dell-Imprimante-coul..> 02-Nov-2012 09:38  1.9M  
 Dell-Projecteur-Dell..> 02-Nov-2012 09:38  2.0M  
 Dell-M770mm-Color-Mo..> 02-Nov-2012 09:37  2.1M  
 Dell-Precision-M6400..> 02-Nov-2012 09:37  2.1M  
 Dell-Manuel-du-propr..> 01-Nov-2012 19:14  2.6M  
 Dell-Systemes-Dell-P..> 01-Nov-2012 19:02  2.7M  
 Dell-Vostro-270-Manu..> 01-Nov-2012 19:02  2.7M  
 Dell-ALIENWARE-M17x-..> 01-Nov-2012 19:00  2.3M  
 Dell-Precision-Works..> 01-Nov-2012 18:46  3.3M  
 Dell-P513w-User-s-Gu..> 01-Nov-2012 18:46  2.8M  
 Dell-Serveur-de-sauv..> 01-Nov-2012 18:42  1.9M  
 Dell-Inspiron-660-ma..> 01-Nov-2012 18:42  2.0M  
 Dell-P513w-User-s-Gu..> 01-Nov-2012 18:42  2.3M  
 Dell-Studio-XPS-Guid..> 01-Nov-2012 18:41  2.9M  
 Dell-Latitude-D430-G..> 01-Nov-2012 18:41  3.2M  
 Dell-Systemes-Dell-P..> 01-Nov-2012 18:41  2.7M  
 Dell-Matrices-de-sto..> 01-Nov-2012 18:40  1.9M  
 Dell-Vostro-420-220-..> 01-Nov-2012 18:40  2.0M  
 Dell-Guide-de-l-admi..> 01-Nov-2012 18:39  2.2M  
 Dell-Guide-de-l-util..> 01-Nov-2012 18:39  2.1M  
 Dell-INSPIRON-DUO-GU..> 01-Nov-2012 18:38  2.2M  
 Dell-INSPIRON-DUO-SE..> 01-Nov-2012 18:38  2.3M  
 Dell-Adaptateur-hote..> 01-Nov-2012 18:38  2.3M  
 Dell-Studio-XPS-Setu..> 01-Nov-2012 18:38  2.4M  
 Dell-Client-Manageme..> 01-Nov-2012 18:37  2.5M  
 Dell-1230c-Imprimant..> 01-Nov-2012 18:37  2.6M  
 Dell-XPS-8500-Manuel..> 01-Nov-2012 18:36  2.7M  
 Dell-Station-de-trav..> 01-Nov-2012 18:36  2.3M  
 Dell-Inspiron-530-Se..> 29-Oct-2012 07:41  1.9M  
 Dell-Mobile-Jamz.htm    29-Oct-2012 07:41  1.6M  
 Dell-Systemes-Dell-P..> 29-Oct-2012 07:41  2.2M  
 Dell-Dimension-C521-..> 29-Oct-2012 07:41  1.9M  
 Dell-PowerEdge-R910-..> 29-Oct-2012 07:40  2.6M  
 Projecteur-Dell-1201..> 29-Oct-2012 07:40  2.3M  
 Dell-PowerEdge-R520-..> 29-Oct-2012 07:39  3.0M  
 Dell-ALIENWARE-MANUE..> 29-Oct-2012 07:39  2.7M  
 Dell-Inspiron-531-Ma..> 29-Oct-2012 07:38  2.7M  
 Dell-Vostro-200-Manu..> 29-Oct-2012 07:38  2.4M  
 Dell-Systemes -Dell ..> 29-Oct-2012 07:37  3.2M  
 Dell-Systemes-Dell-P..> 29-Oct-2012 07:37  3.0M  
 Dell-PowerEdge-C410x..> 29-Oct-2012 07:36  3.2M  
 Dell-Latitude-E5430-..> 26-Oct-2012 17:29  1.6M  
 Console-de-gestion-m..> 26-Oct-2012 14:51  3.3M  
 DELL-POWERVAULT-MD12..> 26-Oct-2012 14:50  3.3M  
 Dell-PowerEdge-R520-..> 26-Oct-2012 14:50  3.3M  
 Dell-PowerEdge-R620-..> 26-Oct-2012 14:49  3.3M  
 Dell-Ekran-Yönetici..> 26-Oct-2012 14:49  3.4M  
 Dell-PowerVault-MD36..> 26-Oct-2012 14:48  2.4M  
 Dell-PowerVault-MD36..> 26-Oct-2012 14:48  2.8M  
 Dell-OPENMANAGE-POWE..> 26-Oct-2012 14:47  2.7M  
 Dell-Vostro-3460-Man..> 26-Oct-2012 14:47  2.7M  
 Dell-Vostro-3460-Man..> 26-Oct-2012 14:46  2.7M  
 Dell- Vostro-270-Man..> 26-Oct-2012 14:46  2.8M  
 Dell-S320-S320wi-Pro..> 26-Oct-2012 14:45  2.9M  
 Dell-Guide-de-l-util..> 26-Oct-2012 14:45  2.0M  
 Dell-PowerEdge-Siste..> 26-Oct-2012 14:44  1.4M  
 Dell-S2240L-S2340L-M..> 26-Oct-2012 14:44  1.5M  
 Dell-Vostro-1540-155..> 26-Oct-2012 14:44  2.2M  
 Dell-PowerEdge-R720-..> 25-Oct-2012 18:33  2.5M  
 Dell-Inspiron-1720-m..> 25-Oct-2012 18:32  2.9M  
 DELL-OPTIPLEX580-TEC..> 25-Oct-2012 18:32  2.9M  
 Dell-Manuel-du-propr..> 25-Oct-2012 18:31  3.3M  
 Dell-Inspiron-Manuel..> 25-Oct-2012 18:31  3.3M  
 Dell-PowerEdge-R210-..> 25-Oct-2012 18:30  3.6M  
 Dell-Dimension-3000-..> 25-Oct-2012 18:30  3.5M  
 Systemes-Dell-PowerE..> 25-Oct-2012 18:29  2.8M  
 Dell-Solutions-NAS-D..> 25-Oct-2012 18:29  2.7M  
 Dell-Precision-Works..> 25-Oct-2012 12:10  2.0M  
 Dell-Systemes-Dell-P..> 25-Oct-2012 12:10  2.3M  
 Dell-Inspiron-1721-M..> 25-Oct-2012 12:09  2.7M  
 Dell-Vostro-2520-Man..> 25-Oct-2012 12:09  2.8M  
 Dell-Axim-X30-Manuel..> 25-Oct-2012 12:08  3.0M  
 Dell-Inspiron-2600-e..> 25-Oct-2012 12:08  3.2M  
 Dell-Inspiron-9200-M..> 25-Oct-2012 12:07  3.4M  
 Dell-Imprimante-lase..> 25-Oct-2012 12:07  2.1M  
 Dell-Venue-Pro-Manue..> 25-Oct-2012 12:06  2.4M  
 Dell-Streak-7-Franca..> 25-Oct-2012 12:06  2.3M  
 Dell-Photo-Printer-5..> 25-Oct-2012 12:06  2.6M  
 Dell-Vostro-1440-145..> 25-Oct-2012 12:05  2.5M  
 Dell-Manuel-de-l-uti..> 25-Oct-2012 12:05  2.9M  
 Dell-Systemes-Dell-P..> 25-Oct-2012 12:05  3.1M  
 Dell-Manuel-de-l-uti..> 25-Oct-2012 12:04  2.8M  
 Dell-Demarrage-rapid..> 25-Oct-2012 12:04  2.4M  
 Dellâ„¢ Logiciel-de..> 25-Oct-2012 12:03  2.8M  
 Dell-Systeme-de-navi..> 25-Oct-2012 12:02  3.2M  
 Dell-Clavier-sans-fi..> 25-Oct-2012 12:02  3.0M  
 Dell-Inspiron-1200-e..> 25-Oct-2012 09:48  2.4M  
 Dell-PowerVault NX32..> 25-Oct-2012 09:48  2.7M  
 Dell-OptiPlex-9010-7..> 25-Oct-2012 09:48  2.4M  
 Dell-Systemes-Dell-P..> 25-Oct-2012 09:47  2.0M  
 Dell-Vostro-400-Manu..> 25-Oct-2012 09:47  2.3M  
 Dell-Latitude-D630-M..> 25-Oct-2012 09:46  2.9M  
 Dell-PowerEdge-C5125..> 25-Oct-2012 09:46  2.5M  
 Dell-Inspiron-660-Ma..> 24-Oct-2012 09:15  2.3M  
 Dell-Latitude-E5530-..> 24-Oct-2012 09:15  2.4M  
 Dell-Inspiron-1150-M..> 24-Oct-2012 09:15  2.6M  
 Dell-XPS-One-2710-ma..> 24-Oct-2012 09:14  2.8M  
 Dell-Systemes-Dell-P..> 24-Oct-2012 09:14  3.1M  
 Dell-Inspiron-9100-M..> 24-Oct-2012 09:13  2.6M  
 Dell-Dimension-E521-..> 24-Oct-2012 09:12  2.9M  
 Dell-PowerVault-Baie..> 24-Oct-2012 09:12  3.0M  
 Dell-Inspiron-8600-M..> 24-Oct-2012 09:11  3.2M  
 Dell-OptiPlex-9010-T..> 24-Oct-2012 07:54  2.3M  
 Dell-Dimension-3100C..> 24-Oct-2012 07:42  2.7M  
 Dell-Beats-By-dr.dre..> 24-Oct-2012 07:42  2.7M  
 Dell-Axim-X51-X51v-M..> 24-Oct-2012 07:42  2.9M  
 Dell-MANUEL-ALIENWAR..> 24-Oct-2012 07:41  2.4M  
 Dell-poweredge-r210-..> 24-Oct-2012 07:41  2.5M  
 Dell-server-poweredg..> 24-Oct-2012 07:40  2.5M  
 Dell-server-poweredg..> 24-Oct-2012 07:40  2.6M  
 Dell-server-poweredg..> 24-Oct-2012 07:39  2.3M  
 Dell-server-poweredg..> 24-Oct-2012 07:39  2.4M  
 Dell-Systemes-Dell-I..> 24-Oct-2012 07:39  2.1M  
 Dell-Latitude-E6320-..> 24-Oct-2012 07:38  2.1M  
 Dell-Latitude-5420-E..> 24-Oct-2012 07:38  2.1M  
 Dell-server-poweredg..> 24-Oct-2012 07:37  1.9M  
 Dell-Systemes-Dell-P..> 24-Oct-2012 07:37  2.2M  
 Dell-Vostro-3560-Man..> 24-Oct-2012 07:37  1.9M  
 Dell-Manuel-du-propr..> 24-Oct-2012 07:36  2.2M  
 Acceder-au-site-Dell..> 24-Oct-2012 06:36  1.0M  
 Dell-Vostro-360-Prop..> 19-Oct-2012 07:42  1.7M  
 Dell-OPENMANAGE-POWE..> 19-Oct-2012 07:41  1.9M  
 Dell-ALIENWARE-MANUE..> 19-Oct-2012 07:41  2.0M  
 Dell-Vostro-200-Manu..> 19-Oct-2012 07:41  2.4M  
 Dell-Precision-Works..> 19-Oct-2012 07:41  2.1M  
 Dell-Streak-7-Manuel..> 18-Oct-2012 17:13  2.9M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 17:13  3.6M  
 Dell-Manuel-du-propr..> 18-Oct-2012 17:13  2.9M  
 Dell-MANUEL-D-ALIENW..> 18-Oct-2012 17:12  3.1M  
 Dell-Inspiron-9300-M..> 18-Oct-2012 17:12  3.3M  
 Dell-Systemes-Dell-I..> 18-Oct-2012 17:11  3.6M  
 Dell-PowerEdge-R620-..> 18-Oct-2012 17:11  3.9M  
 Dell-Manuel-d-utilis..> 18-Oct-2012 17:10  3.1M  
 Dell-Precision-Works..> 18-Oct-2012 17:09  3.2M  
 Dell-Inspiron-13z-Ma..> 18-Oct-2012 17:09  3.3M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 17:08  3.6M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 17:08  2.6M  
 Dell-Boîtier-Dell-P..> 18-Oct-2012 17:07  2.7M  
 Dell-Manuel-du-propr..> 18-Oct-2012 17:07  3.1M  
 DELLmanuelsutilisate..> 18-Oct-2012 17:06   12M  
 Dell-Inspiron-5100-e..> 18-Oct-2012 17:05  4.4M  
 Dell-Manuel-de-l-Uti..> 18-Oct-2012 17:04  4.1M  
 Dell-MANUEL-D-ALIENW..> 18-Oct-2012 17:03  4.1M  
 Dell-Manuel-de-l-uti..> 18-Oct-2012 17:02  3.9M  
 Dell-Laser-Printer-3..> 18-Oct-2012 17:02  3.8M  
 Dell-Inspiron-530s-M..> 18-Oct-2012 17:01  3.7M  
 Dell-Liste-des-manue..> 18-Oct-2012 17:01  3.5M  
 Dell-Inspiron-530s-M..> 18-Oct-2012 17:00  3.5M  
 Dell-Vostro-V131-Man..> 18-Oct-2012 16:59  3.4M  
 DellDimension1100Ser..> 18-Oct-2012 16:59  3.4M  
 Dell-Vostro-3750-Man..> 18-Oct-2012 16:58  3.4M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 16:58  3.4M  
 Imprimante-personnel..> 18-Oct-2012 16:57  3.4M  
 Dell-Inspiron-17R-Ma..> 18-Oct-2012 16:56  3.3M  
 Dell-PowerVault-NX40..> 18-Oct-2012 16:56  3.2M  
 Dell-Manuel-du-propr..> 18-Oct-2012 16:55  3.3M  
 Dell-Matrices-de-sto..> 18-Oct-2012 16:55  3.2M  
 Dell-Dimension-9200-..> 18-Oct-2012 16:54  3.2M  
 AlienwareAurora-R3.htm  18-Oct-2012 16:54  3.2M  
 Dell-Axim-X50-Manuel..> 18-Oct-2012 16:53  3.2M  
 Imprimante-laser-de-..> 18-Oct-2012 16:53  3.2M  
 Dell-Axim-X51-X51v-M..> 18-Oct-2012 16:52  3.2M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 16:52  3.2M  
 AlienwareAuroraAuror..> 18-Oct-2012 16:51  3.1M  
 Dell-MANUEL-ALIENWAR..> 18-Oct-2012 16:51  3.1M  
 Dell-PowerEdge-C8220..> 18-Oct-2012 16:50  3.0M  
 Dell-Dimension-E520-..> 18-Oct-2012 16:50  3.0M  
 Chassis-RAID-Dell-Po..> 18-Oct-2012 16:49  3.0M  
 Dell-XPS-630i-Manuel..> 18-Oct-2012 16:49  3.0M  
 AlienwareAurora-R4.htm  18-Oct-2012 16:48  2.9M  
 Dell-Photo-All-In-On..> 18-Oct-2012 16:48  2.9M  
 Dell-Inspiron-700m-M..> 18-Oct-2012 16:47  2.9M  
 Dell-Systemes-Dell-I..> 18-Oct-2012 16:47  2.9M  
 Dell-Manuel-du-propr..> 18-Oct-2012 16:46  2.9M  
 Dell-Photo-Printer-7..> 18-Oct-2012 16:46  2.8M  
 Dell-PowerVault-MD32..> 18-Oct-2012 16:45  2.8M  
 Dell-Photo-All-In-On..> 18-Oct-2012 16:45  2.8M  
 Dell-Manuel-du-propr..> 18-Oct-2012 16:44  2.8M  
 Dell-Imprimante-lase..> 18-Oct-2012 16:44  2.8M  
 Dell-moniteur-D1920-..> 18-Oct-2012 16:43  2.7M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 16:43  2.8M  
 Dell-Latitude-XT3-Ma..> 18-Oct-2012 16:42  2.7M  
 AlienwareArea-51Area..> 18-Oct-2012 16:42  2.7M  
 Dell-Imprimante-lase..> 18-Oct-2012 16:41  2.7M  
 Dell-Baie-de-stockag..> 18-Oct-2012 16:41  2.7M  
 Dell-Streak-Manuel-d..> 18-Oct-2012 16:40  2.7M  
 Imprimante-Dell-Phot..> 18-Oct-2012 16:39  2.6M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 16:39  2.6M  
 Dell-Clavier-Axim-Ma..> 18-Oct-2012 16:38  2.6M  
 Dell-Latitude-ST-Man..> 18-Oct-2012 16:38  2.6M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 16:38  2.5M  
 alienwareX51.htm        18-Oct-2012 16:37  2.5M  
 Dell-Manuel-du-propr..> 18-Oct-2012 16:37  2.5M  
 Dell-Systemes-Dell-P..> 18-Oct-2012 16:36  2.5M  
 Dell-Imprimante-lase..> 18-Oct-2012 16:36  2.5M  
 Dell-Photo-All-In-On..> 18-Oct-2012 16:35  2.3M  
 Dell-Manuel-de-maint..> 18-Oct-2012 16:35  2.2M  
 Dell-Manuel-d-utilis..> 18-Oct-2012 16:35  2.3M  
 Dell-PowerVault-MD32..> 18-Oct-2012 16:34  2.2M  
 Dell-XP-M1530-Manuel..> 18-Oct-2012 16:34  2.2M  
 Dell-Inspiron-1100-M..> 18-Oct-2012 16:33  2.2M  
 Dell-MANUEL-ALIENWAR..> 18-Oct-2012 16:33  2.1M  
 Dell-Matrices-de-sto..> 18-Oct-2012 16:33  2.1M  
 Dell-Inspiron-9400-E..> 18-Oct-2012 16:32  2.0M  
 Dell-Imprimante-lase..> 18-Oct-2012 16:32  1.9M  
 Dell-Laser-Printer-1..> 18-Oct-2012 16:32  1.6M  
 Dell-Inspiron-1525-1..> 18-Oct-2012 16:31  1.5M  
 Dell-Tout-en-un-Dell..> 18-Oct-2012 16:31  1.2M  
 Dell-Laser-Printer-1..> 18-Oct-2012 16:31  1.0M  
 Dell-Dimension-3100-..> 18-Oct-2012 16:31  906K 
Autres Manuels :

[TXT]

 16-4ppm-Imprimante-l..> 28-Sep-2012 12:42  2.8M  

[TXT]

 16-4ppm-Multifonctio..> 28-Sep-2012 12:43  6.0M  

[TXT]

 16-4ppm-Multifonctio..> 28-Sep-2012 12:43  5.4M  

[TXT]

 16-4ppm-Multifonctio..> 28-Sep-2012 12:45  6.0M  

[TXT]

 16-4ppm-Multifonctio..> 28-Sep-2012 12:45  4.3M  

[TXT]

 17-3-Serie-3-300E7A-..> 28-Sep-2012 12:46  3.9M  

[TXT]

 19-Serie-3-Moniteur-..> 28-Sep-2012 12:47  4.7M  

[TXT]

 20ppm-Multifonction-..> 28-Sep-2012 12:48  6.0M  

[TXT]

 24ppm-Multifonction-..> 28-Sep-2012 12:49  6.5M  

[TXT]

 27-Serie7-Moniteur-s..> 28-Sep-2012 12:50  4.8M  

[TXT]

 32-LE32D450WXZF-seri..> 28-Sep-2012 12:51  5.7M  

[TXT]

 32-UE32D6200WXZF-ser..> 28-Sep-2012 12:51  4.6M  

[TXT]

 35-35ppm-Copieur-cou..> 28-Sep-2012 12:53  6.5M  

[TXT]

 40-UE40D6500WXZF-ser..> 28-Sep-2012 12:53  3.6M  

[TXT]

 46-LE46D550WXZF-seri..> 28-Sep-2012 12:55  6.9M  

[   ]

 AEWG.pdf                26-Jun-2009 07:09  5.4M  

[   ]

 AEWK.pdf                30-Jun-2009 07:41  3.9M  

[TXT]

 APPLEmanuelutilisate..> 28-Sep-2012 12:32  7.0M  

[TXT]

 AcerPowerseriemanuel..> 28-Sep-2012 12:30   34K  

[TXT]

 Apple-Manuel_de_l'ut..> 28-Sep-2012 12:28  2.1M  

[TXT]

 Apple-Manuel_de_l_ut..> 28-Sep-2012 12:29  3.6M  

[TXT]

 Apple-Manuel_de_l_ut..> 28-Sep-2012 12:30  3.4M  

[TXT]

 Apple-Manuel_de_l_ut..> 28-Sep-2012 12:30  3.8M  

[TXT]

 CIELQUANTUM450manuel..> 28-Sep-2012 12:31  733K  

[TXT]

 Dell-1130-Dell-1130n..> 13-May-2013 12:06  3.1M  

[TXT]

 Dell-7330dn-Mono-Las..> 13-May-2013 12:06  2.8M  

[TXT]

 Dell-Alienware-Area-..> 13-May-2013 12:07  3.1M  

[TXT]

 Dell-Alienware-Area-..> 13-May-2013 12:07  4.1M  

[TXT]

 Dell-Alienware-Area-..> 13-May-2013 12:08  3.2M  

[TXT]

 Dell-Alienware-M15x-..> 13-May-2013 12:08  2.8M  

[TXT]

 Dell-Alienware-M15x-..> 13-May-2013 12:09  3.3M  

[TXT]

 Dell-Alienware-X51-M..> 13-May-2013 12:09  2.7M  

[TXT]

 Dell-Aztech-MDP3900-..> 13-May-2013 12:09  2.0M  

[TXT]

 Dell-Comment-utilise..> 13-May-2013 12:10  2.7M  

[TXT]

 Dell-Configurer-et-u..> 13-May-2013 12:10  2.7M  

[TXT]

 Dell-DR4000-Manuels.htm 13-May-2013 12:12  3.4M  

[TXT]

 Dell-Dimension-5100-..> 13-May-2013 12:11  3.4M  

[TXT]

 Dell-Dimension-8300-..> 13-May-2013 12:11  2.5M  

[TXT]

 Dell-Drivers-for-Del..> 13-May-2013 12:13  4.2M  

[TXT]

 Dell-Drivers-for-Pow..> 13-May-2013 12:13  4.3M  

[TXT]

 Dell-Guide-Utilisate..> 13-May-2013 12:14  2.4M  

[TXT]

 Dell-Guide-d-utilisa..> 13-May-2013 12:13  2.8M  

[TXT]

 Dell-Inspiron-15-Int..> 13-May-2013 12:14  3.0M  

[TXT]

 Dell-Inspiron-500m-M..> 13-May-2013 12:17  2.8M  

[TXT]

 Dell-Inspiron-510m-M..> 13-May-2013 12:18  3.2M  

[TXT]

 Dell-Inspiron-600m-M..> 13-May-2013 12:18  2.6M  

[TXT]

 Dell-Inspiron-620-Ma..> 13-May-2013 12:19  3.2M  

[TXT]

 Dell-Inspiron-640M-M..> 13-May-2013 12:19  3.7M  

[TXT]

 Dell-Inspiron-1520-2..> 13-May-2013 12:15  2.5M  

[TXT]

 Dell-Inspiron-1520-E..> 13-May-2013 12:15  1.9M  

[TXT]

 Dell-Inspiron-1520-M..> 13-May-2013 12:16  2.0M  

[TXT]

 Dell-Inspiron-1521-M..> 13-May-2013 12:16  2.9M  

[TXT]

 Dell-Inspiron-1525-M..> 13-May-2013 12:17  3.9M  

[TXT]

 Dell-Inspiron-9400-M..> 13-May-2013 12:20  4.1M  

[TXT]

 Dell-Inspiron-Duo-Ma..> 13-May-2013 12:20  3.0M  

[TXT]

 Dell-Inspiron-One-23..> 13-May-2013 12:21  4.2M  

[TXT]

 Dell-Inspiron-One-23..> 13-May-2013 12:22  2.8M  

[TXT]

 Dell-Inspiron-m301z-..> 13-May-2013 12:22  4.8M  

[TXT]

 Dell-Intel-Active-Ma..> 13-May-2013 12:23  4.7M  

[TXT]

 Dell-Latitude-CPi-A-..> 13-May-2013 12:23  2.7M  

[TXT]

 Dell-Latitude-Cpi-Ma..> 13-May-2013 12:24  3.2M  

[TXT]

 Dell-Latitude-D410-M..> 13-May-2013 12:24  3.0M  

[TXT]

 Dell-Latitude-D620-E..> 13-May-2013 12:25  3.7M  

[TXT]

 Dell-Latitude-D620-M..> 13-May-2013 12:25  2.3M  

[TXT]

 Dell-Latitude-D630-M..> 13-May-2013 12:26  4.7M  

[TXT]

 Dell-Latitude-E5520-..> 13-May-2013 12:27  3.5M  

[TXT]

 Dell-Latitude-E6400-..> 13-May-2013 12:28  3.9M  

[TXT]

 Dell-Latitude-E6400-..> 13-May-2013 12:29  4.2M  

[TXT]

 Dell-Latitude-E6400-..> 13-May-2013 12:28  3.2M  

[TXT]

 Dell-Latitude-E6410-..> 13-May-2013 12:29  3.8M  

[TXT]

 Dell-Latitude-E6420-..> 13-May-2013 12:30  3.1M  

[TXT]

 Dell-Latitude-E6430-..> 13-May-2013 12:30  3.4M  

[TXT]

 Dell-Latitude-E6530-..> 13-May-2013 12:31  2.4M  

[TXT]

 Dell-Latitude-E6530-..> 13-May-2013 12:31  2.3M  

[TXT]

 Dell-Latitude-XT2-Ma..> 13-May-2013 12:32  3.5M  

[TXT]

 Dell-Lifecycle-Contr..> 13-May-2013 12:32  4.3M  

[TXT]

 Dell-Manuals-for-Ali..> 13-May-2013 12:33  3.0M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:36  4.3M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:33  2.6M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:34  2.5M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:34  2.6M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:34  2.2M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:35  2.1M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:36  3.5M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:37  2.5M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:37  2.5M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:38  3.4M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:37  2.0M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 12:38  2.7M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 13:24  2.1M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 13:25  3.5M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 13:25  2.0M  

[TXT]

 Dell-Manuals-for-Del..> 13-May-2013 13:26  3.7M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:27  1.8M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:27  1.6M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:26  3.5M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:27  1.6M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:28  2.3M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:28  2.1M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:28  1.6M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:29  3.7M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:29  2.9M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:30  1.7M  

[TXT]

 Dell-Manuals-for-Ins..> 13-May-2013 13:30  1.9M  

[TXT]

 Dell-Manuals-for-LCD..> 13-May-2013 13:32  2.7M  

[TXT]

 Dell-Manuals-for-Lat..> 13-May-2013 13:30  2.8M  

[TXT]

 Dell-Manuals-for-Lat..> 13-May-2013 13:31  3.4M  

[TXT]

 Dell-Manuals-for-Lat..> 13-May-2013 13:31  1.6M  

[TXT]

 Dell-Manuals-for-Lat..> 13-May-2013 13:32  3.5M  

[TXT]

 Dell-Manuals-for-Min..> 13-May-2013 13:33  2.6M  

[TXT]

 Dell-Manuals-for-Opt..> 13-May-2013 13:33  2.0M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:34  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:33  2.0M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:34  3.2M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:35  3.6M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:35  1.5M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:36  3.1M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:36  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:37  3.5M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:37  2.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:38  2.9M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:38  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:39  3.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:39  2.7M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:38  2.2M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:40  3.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:40  3.0M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:41  2.7M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:41  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:41  2.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:42  2.8M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:43  3.3M  

[TXT]

 Dell-Manuals-for-Pow..> 13-May-2013 13:43  4.0M  

[TXT]

 Dell-Manuals-for-Pre..> 13-May-2013 13:43  2.5M  

[TXT]

 Dell-Manuals-for-Vos..> 13-May-2013 13:44  3.6M  

[TXT]

 Dell-Manuals-for-XPS..> 13-May-2013 13:44  1.9M  

[TXT]

 Dell-Manuals-for-XPS..> 13-May-2013 13:45  2.5M  

[TXT]

 Dell-Manuals-for-XPS..> 13-May-2013 13:45  2.6M  

[TXT]

 Dell-Manuals-for-XPS..> 13-May-2013 13:45  2.3M  

[TXT]

 Dell-Manuel-d-Utilis..> 13-May-2013 13:46  2.4M  

[TXT]

 Dell-Manuel-d-utilis..> 13-May-2013 13:46  2.3M  

[TXT]

 Dell-Manuel-de-maint..> 13-May-2013 13:47  3.0M  

[TXT]

 Dell-Manuels-et-docu..> 13-May-2013 13:47  3.7M  

[TXT]

 Dell-Manuels-et-docu..> 13-May-2013 13:48  3.5M  

[TXT]

 Dell-OptiPlex-330-Ma..> 13-May-2013 13:48  2.2M  

[TXT]

 Dell-OptiPlex-745-Ma..> 13-May-2013 13:49  3.9M  

[TXT]

 Dell-OptiPlex-755-Ma..> 13-May-2013 13:50  5.5M  

[TXT]

 Dell-OptiPlex-SX280-..> 13-May-2013 13:51  6.0M  

[TXT]

 Dell-PowerConnect-55..> 13-May-2013 13:51  4.5M  

[TXT]

 Dell-PowerEdge-300-M..> 13-May-2013 13:53  4.7M  

[TXT]

 Dell-PowerEdge-400SC..> 13-May-2013 13:53  2.1M  

[TXT]

 Dell-PowerEdge-1950-..> 13-May-2013 13:52  2.2M  

[TXT]

 Dell-PowerEdge-M905-..> 13-May-2013 13:54  2.0M  

[TXT]

 Dell-PowerEdge-R200-..> 13-May-2013 13:54  2.6M  

[TXT]

 Dell-PowerEdge-R320-..> 13-May-2013 13:55  4.4M  

[TXT]

 Dell-PowerEdge-R510-..> 13-May-2013 13:55  3.4M  

[TXT]

 Dell-PowerEdge-R510-..> 13-May-2013 13:56  2.7M  

[TXT]

 Dell-PowerEdge-R610-..> 13-May-2013 13:56  2.9M  

[TXT]

 Dell-PowerEdge-R620-..> 13-May-2013 13:57  4.1M  

[TXT]

 Dell-PowerEdge-R720x..> 13-May-2013 13:57  3.1M  

[TXT]

 Dell-PowerEdge-R815-..> 13-May-2013 13:58  4.3M  

[TXT]

 Dell-PowerEdge-R815-..> 13-May-2013 13:58  2.8M  

[TXT]

 Dell-PowerEdge-R900-..> 13-May-2013 13:59  3.1M  

[TXT]

 Dell-PowerEdge-T100-..> 13-May-2013 13:59  3.0M  

[TXT]

 Dell-PowerEdge-T420-..> 13-May-2013 14:00  3.2M  

[TXT]

 Dell-PowerEdge-T605-..> 13-May-2013 14:00  2.8M  

[TXT]

 Dell-PowerEdge-T710-..> 13-May-2013 14:01  2.9M  

[TXT]

 Dell-PowerVault-110T..> 13-May-2013 14:02  4.4M  

[TXT]

 Dell-PowerVault-NX30..> 13-May-2013 14:03  5.6M  

[TXT]

 Dell-Precision-360-M..> 13-May-2013 14:03  4.0M  

[TXT]

 Dell-Precision-370-M..> 13-May-2013 14:04  3.2M  

[TXT]

 Dell-Precision-390-M..> 13-May-2013 14:04  2.0M  

[TXT]

 Dell-Precision-450-M..> 13-May-2013 14:05  4.6M  

[TXT]

 Dell-Precision-610-M..> 13-May-2013 14:05  2.3M  

[TXT]

 Dell-Precision-690-M..> 13-May-2013 14:06  3.2M  

[TXT]

 Dell-Precision-M20-M..> 13-May-2013 14:06  2.8M  

[TXT]

 Dell-Precision-M40-M..> 13-May-2013 14:07  3.9M  

[TXT]

 Dell-Precision-M4400..> 13-May-2013 14:07  3.3M  

[TXT]

 Dell-Precision-M4500..> 13-May-2013 14:09  6.1M  

[TXT]

 Dell-Precision-M4500..> 13-May-2013 14:08  2.2M  

[TXT]

 Dell-Precision-M4600..> 13-May-2013 14:09  3.4M  

[TXT]

 Dell-Precision-M4700..> 13-May-2013 14:10  3.4M  

[TXT]

 Dell-Precision-T5600..> 13-May-2013 14:10  3.3M  

[TXT]

 Dell-Precision-T5600..> 13-May-2013 14:11  3.1M  

[TXT]

 Dell-Precision-T7600..> 13-May-2013 14:11  3.2M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:13  4.1M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:12  2.5M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:13  2.2M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:13  2.7M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:13  2.2M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:14  2.8M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:15  2.7M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:14  2.6M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:15  3.2M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:16  2.6M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:16  2.7M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:17  2.7M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:17  1.5M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:18  4.3M  

[TXT]

 Dell-Product-support..> 13-May-2013 14:18  4.1M  

[TXT]

 Dell-Studio-1555-15-..> 13-May-2013 14:19  3.1M  

[TXT]

 Dell-Studio-1735-Man..> 13-May-2013 14:19  3.1M  

[TXT]

 Dell-Studio-Desktop-..> 13-May-2013 14:28  2.7M  

[TXT]

 Dell-Studio-Slim-Man..> 13-May-2013 14:28  5.1M  

[TXT]

 Dell-Symantec-Backup..> 13-May-2013 14:29  3.0M  

[TXT]

 Dell-UPS-500- Englis..> 13-May-2013 14:30  4.6M  

[TXT]

 Dell-UPS-500T-Españ..> 13-May-2013 14:29  1.7M  

[TXT]

 Dell-UPS-500T-Manuel..> 13-May-2013 14:30  3.4M  

[TXT]

 Dell-Vizioncore-Manu..> 13-May-2013 14:31  2.1M  

[TXT]

 Dell-Vostro-200-Manu..> 13-May-2013 14:33  4.5M  

[TXT]

 Dell-Vostro-270-Manu..> 13-May-2013 14:34  3.2M  

[TXT]

 Dell-Vostro-270s-Man..> 13-May-2013 14:34  3.1M  

[TXT]

 Dell-Vostro-410-Manu..> 13-May-2013 14:36  4.1M  

[TXT]

 Dell-Vostro-1000-Man..> 13-May-2013 14:31  2.7M  

[TXT]

 Dell-Vostro-1550-Man..> 13-May-2013 14:32  3.4M  

[TXT]

 Dell-Vostro-1700-Man..> 13-May-2013 14:33  4.8M  

[TXT]

 Dell-Vostro-3450-Man..> 13-May-2013 14:35  2.8M  

[TXT]

 Dell-Vostro-3750-Man..> 13-May-2013 14:35  3.0M  

[TXT]

 Dell-Windows-8-Manue..> 13-May-2013 14:37  5.1M  

[TXT]

 Dell-XPS-630-Manuels..> 13-May-2013 14:37  3.6M  

[TXT]

 Dell-XPS-M1210-Owner..> 13-May-2013 14:38  2.9M  

[TXT]

 Dell-XPS-M1730-Manue..> 13-May-2013 14:38  3.9M  

[TXT]

 EBP-Guide_Auto-entre..> 28-Sep-2012 12:31   78K  

[TXT]

 EBPGestionCommercial..> 28-Sep-2012 12:35  1.4M  

[TXT]

 EBPPAYEV14manuelutil..> 28-Sep-2012 12:35  865K  

[TXT]

 EBPPointdeventebacko..> 28-Sep-2012 12:35  736K  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:31  1.9M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:32  1.9M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:33  1.6M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:33  1.8M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:33  1.0M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:33  1.1M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:33  1.2M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:34  1.9M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:34  1.3M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:34  1.4M  

[TXT]

 EBP_Manuel_Utilisate..> 28-Sep-2012 12:34  1.5M  

[TXT]

 EBPlocationimmobilie..> 28-Sep-2012 12:34  182K  

[   ]

 GENETATS.pdf            26-Jun-2009 07:09  4.8M  

[TXT]

 Galaxy-S-Advance-GT-..> 28-Sep-2012 12:55  5.5M  

[TXT]

 Galaxy-Y-S5360-Andro..> 28-Sep-2012 12:56  3.2M  

[TXT]

 Guide-d-installation..> 28-Sep-2012 12:35  606K  

[TXT]

 Guide-d-installation..> 28-Sep-2012 12:35  606K  

[   ]

 GuideCRC.pdf            30-Jun-2009 07:40  1.0M  

[TXT]

 Guide_Assistants_Jur..> 28-Sep-2012 12:35  132K  

[TXT]

 Guide_Auto-entrepren..> 28-Sep-2012 12:35   81K  

[TXT]

 Guide_CRM_PRO_2013-M..> 28-Sep-2012 12:36  785K  

[TXT]

 Guide_Compta-Classic..> 28-Sep-2012 12:35  204K  

[TXT]

 Guide_Compta-GC_Open..> 28-Sep-2012 12:35  387K  

[TXT]

 Guide_Compta-Gestion..> 28-Sep-2012 12:35  548K  

[TXT]

 Guide_Compta-Open_Li..> 28-Sep-2012 12:35  628K  

[TXT]

 Guide_Compta_Pratic_..> 28-Sep-2012 12:35  684K  

[TXT]

 Guide_Devis_et_Factu..> 28-Sep-2012 12:36  859K  

[TXT]

 Guide_Devis_et_Factu..> 28-Sep-2012 12:36  960K  

[TXT]

 Guide_EBP_Facturatio..> 28-Sep-2012 12:36  1.0M  

[TXT]

 Guide_GC_Open_Line_P..> 28-Sep-2012 12:36  1.2M  

[TXT]

 Guide_GESTION_COMMER..> 28-Sep-2012 12:37  1.3M  

[TXT]

 Guide_Gestion_de_Con..> 28-Sep-2012 12:37  1.4M  

[TXT]

 Guide_Mon_Associatio..> 28-Sep-2012 12:37  1.5M  

[TXT]

 Guide_Paye_Classic_2..> 28-Sep-2012 12:37  1.5M  

[TXT]

 Guide_Paye_Open_Line..> 28-Sep-2012 12:38  1.6M  

[TXT]

 Guide_Report_Designe..> 28-Sep-2012 12:38  1.7M  

[TXT]

 GuidedetelecopieManu..> 28-Sep-2012 12:38  8.4K  

[TXT]

 LE40D503F7W-Samsung-..> 28-Sep-2012 12:57  6.3M  

[TXT]

 LE55C650-LE55C650L1W..> 28-Sep-2012 12:58  6.3M  

[TXT]

 Liste-Manuels-Utilis..> 28-Sep-2012 12:57   17K  

[TXT]

 Liste-Manuels-Utilis..> 29-Sep-2012 21:58   35K  

[   ]

 MEWGE.pdf               26-Jun-2009 07:12   12M  

[   ]

 ME_WKE.pdf              30-Jun-2009 07:43  7.5M  

[TXT]

 Manuels-Utilisateur-..> 28-Sep-2012 13:03  3.4M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 12:58  4.1M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 12:59  4.4M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 13:01  3.8M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 13:01  3.8M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 12:59  2.8M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 13:00  2.5M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 13:00  2.8M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 13:02  3.5M  

[TXT]

 Manuels-de-l-Utilisa..> 28-Sep-2012 13:03  4.1M  

[TXT]

 Micro-chaine-MM-D330..> 28-Sep-2012 13:04  3.9M  

[TXT]

 Microsoftphotopremiu..> 28-Sep-2012 12:41  242K  

[TXT]

 N145Plus-NP-N145P-Ma..> 28-Sep-2012 13:05  3.9M  

[TXT]

 N150-NP-N150-Manuels..> 28-Sep-2012 13:05  3.9M  

[TXT]

 Nexus-S-noir-Open-ma..> 28-Sep-2012 13:06  4.0M  

[TXT]

 OrdinateurportableHP..> 28-Sep-2012 12:38  240K  

[TXT]

 Samsung-32-LE32D450W..> 28-Sep-2012 13:07  4.0M  

[TXT]

 Samsung-46-UE46D5700..> 28-Sep-2012 13:08  4.6M  

[TXT]

 Samsung-AQ18UGFN-Man..> 28-Sep-2012 13:08  3.4M  

[TXT]

 Samsung-AQV18UGAX-Ma..> 28-Sep-2012 13:09  3.7M  

[TXT]

 Samsung-CW21Z503N-Ma..> 28-Sep-2012 13:10  3.3M  

[TXT]

 Samsung-Congelateur-..> 28-Sep-2012 13:09  3.8M  

[TXT]

 Samsung-DA-E550-CN-M..> 28-Sep-2012 13:10  2.4M  

[TXT]

 Samsung-E-MANUAL-X9D..> 28-Sep-2012 13:11  3.1M  

[TXT]

 Samsung-GALAXY-NEXUS..> 28-Sep-2012 13:11  1.4M  

[TXT]

 Samsung-GALAXY-Note-..> 28-Sep-2012 13:14  3.4M  

[TXT]

 Samsung-GALAXY-S-II-..> 28-Sep-2012 13:15  3.4M  

[TXT]

 Samsung-GALAXY-Tab-1..> 28-Sep-2012 13:18  1.9M  

[TXT]

 Samsung-GALAXY-Tab-G..> 28-Sep-2012 13:22  5.0M  

[TXT]

 Samsung-GALAXY-Tab-S..> 28-Sep-2012 13:21  2.4M  

[TXT]

 Samsung-GT-B5310-Man..> 28-Sep-2012 13:23  3.9M  

[TXT]

 Samsung-GT-N8000-CN-..> 28-Sep-2012 13:23  1.0M  

[TXT]

 Samsung-GT-S5360-Man..> 28-Sep-2012 13:24  3.8M  

[TXT]

 Samsung-GT-S5360_UM_..> 28-Sep-2012 13:24  3.2M  

[TXT]

 Samsung-Galaxy-Ace-n..> 28-Sep-2012 13:11  3.0M  

[TXT]

 Samsung-Galaxy-Note-..> 28-Sep-2012 13:13  4.6M  

[TXT]

 Samsung-Galaxy-S-II-..> 28-Sep-2012 13:15  2.8M  

[TXT]

 Samsung-Galaxy-S-III..> 28-Sep-2012 13:16  3.4M  

[TXT]

 Samsung-Galaxy-S-Plu..> 28-Sep-2012 13:17  4.3M  

[TXT]

 Samsung-Galaxy-S-noi..> 28-Sep-2012 13:16  3.2M  

[TXT]

 Samsung-Galaxy-S2-GT..> 28-Sep-2012 13:17  3.3M  

[TXT]

 Samsung-Galaxy-Tab-2..> 28-Sep-2012 13:20  6.5M  

[TXT]

 Samsung-Galaxy-Tab-7..> 28-Sep-2012 13:21  6.8M  

[TXT]

 Samsung-Galaxy-Tab-1..> 28-Sep-2012 13:18  3.6M  

[TXT]

 Samsung-Galaxy-Tab-1..> 28-Sep-2012 13:18  3.6M  

[TXT]

 Samsung-Galaxy-Xcove..> 28-Sep-2012 13:23  4.8M  

[TXT]

 Samsung-Galaxy-mini-..> 28-Sep-2012 13:12  3.9M  

[TXT]

 Samsung-Galaxy-noir-..> 28-Sep-2012 13:12  3.6M  

[TXT]

 Samsung-LA46C550J1F-..> 28-Sep-2012 13:25  1.3M  

[TXT]

 Samsung-LE40S71B-Man..> 28-Sep-2012 13:26  4.0M  

[TXT]

 Samsung-LE46A676-LE4..> 28-Sep-2012 13:26  2.5M  

[TXT]

 Samsung-Lecteur-Mult..> 28-Sep-2012 13:27  4.2M  

[TXT]

 Samsung-NP-R530-NP-R..> 28-Sep-2012 13:28  3.1M  

[TXT]

 Samsung-Nexus-S-noir..> 28-Sep-2012 13:27  3.3M  

[TXT]

 Samsung-Omnia-7-noir..> 28-Sep-2012 13:28  3.4M  

[TXT]

 Samsung-Omnia-II-noi..> 28-Sep-2012 13:29  3.4M  

[TXT]

 Samsung-Omnia-II-noi..> 28-Sep-2012 13:29  3.4M  

[TXT]

 Samsung-Omnia-Lite-n..> 28-Sep-2012 13:30  4.3M  

[TXT]

 Samsung-Omnia-Pro-B7..> 28-Sep-2012 13:31  4.3M  

[TXT]

 Samsung-Omnia-W-noir..> 28-Sep-2012 13:32  4.1M  

[TXT]

 Samsung-Player-Addic..> 28-Sep-2012 13:32  3.8M  

[TXT]

 Samsung-Player-Duo-n..> 28-Sep-2012 13:33  3.6M  

[TXT]

 Samsung-Player-HD-no..> 28-Sep-2012 13:33  3.6M  

[TXT]

 Samsung-RR92HASX-Man..> 28-Sep-2012 13:34  3.6M  

[TXT]

 Samsung-Refrigerateu..> 28-Sep-2012 13:34  3.5M  

[TXT]

 Samsung-SCH-W999-CN-..> 28-Sep-2012 13:35  1.2M  

[TXT]

 Samsung-Samsung-Gala..> 28-Sep-2012 13:35  3.4M  

[TXT]

 Samsung-Samsung-Gala..> 28-Sep-2012 13:36  4.8M  

[TXT]

 Samsung-UA32ES5500-U..> 28-Sep-2012 13:36  1.7M  

[TXT]

 Samsung-UE26EH4000-Z..> 28-Sep-2012 13:37  4.2M  

[TXT]

 Samsung-UE32ES6710-Z..> 28-Sep-2012 13:37  4.3M  

[TXT]

 Samsung-UE40C6000-UE..> 28-Sep-2012 13:38  3.1M  

[TXT]

 Samsung-UE40C6700-UE..> 28-Sep-2012 13:38  3.0M  

[TXT]

 Samsung-UE46C7700-UE..> 28-Sep-2012 13:39  3.2M  

[TXT]

 Samsung-UE46ES6100W-..> 28-Sep-2012 13:40  3.5M  

[TXT]

 Samsung-UE46ES8000-Z..> 28-Sep-2012 13:40  3.6M  

[TXT]

 Samsung-UE50EH5300W-..> 28-Sep-2012 13:41  3.7M  

[TXT]

 Samsung-UE55ES6300-Z..> 28-Sep-2012 13:42  3.6M  

[TXT]

 Samsung-UE55ES6560S-..> 28-Sep-2012 13:42  3.0M  

[TXT]

 Samsung-WEP480-CN-Ma..> 28-Sep-2012 13:49  1.3M  

[TXT]

 Samsung-Wave-3-noir-..> 28-Sep-2012 13:43  4.9M  

[TXT]

 Samsung-Wave-533-noi..> 28-Sep-2012 13:43  4.6M  

[TXT]

 Samsung-Wave-575-bla..> 28-Sep-2012 13:45  4.6M  

[TXT]

 Samsung-Wave-578-noi..> 28-Sep-2012 13:45  4.2M  

[TXT]

 Samsung-Wave-723-gri..> 28-Sep-2012 13:47  7.0M  

[TXT]

 Samsung-Wave-M-noir-..> 28-Sep-2012 13:47  3.9M  

[TXT]

 Samsung-Wave-M-noir-..> 28-Sep-2012 13:49  5.6M  

[TXT]

 Samsung-Wave-noir-Op..> 28-Sep-2012 13:48  3.6M  

[TXT]

 Samsung-XE700T1A-HF1..> 28-Sep-2012 13:50  3.9M  

[TXT]

 Serie-3-300E7A-NP300..> 28-Sep-2012 13:50  3.9M  

[TXT]

 UE55ES8000-ZF-Slim-L..> 28-Sep-2012 13:51  3.8M  

[TXT]

 UE55ES8000-ZF-Slim-L..> 28-Sep-2012 13:52  6.6M  

[TXT]

 UE60ES6100WXZF-UE60E..> 28-Sep-2012 13:54  7.3M  

[TXT]

 UE65C8700-UE65C8700X..> 28-Sep-2012 13:54  7.3M  

[TXT]

 bizhub-350-250-User-..> 28-Sep-2012 12:39  2.8M  

[TXT]

 bizhub-423-363-283-2..> 28-Sep-2012 12:40  2.4M  

[TXT]

 bizhub-C35-French-Sh..> 28-Sep-2012 12:41  3.3M  

[TXT]

 bizhub-C252P-User-Ma..> 28-Sep-2012 12:40  3.2M  

[TXT]

 bizhub-pro-c5501_um_..> 28-Sep-2012 12:40  226K  

[TXT]

 bizhub C360-C280-C22..> 28-Sep-2012 12:39  3.8M  

[TXT]

 bizhubPROC5500manuel..> 28-Sep-2012 12:41  709K  

[TXT]

 cielcomptaevolution1..> 28-Sep-2012 12:30  497K  

[   ]

 generateurtableaubor..> 26-Jun-2009 07:07  1.6M  

[TXT]

 guidedereferenceCiel..> 04-Oct-2011 16:15  354K  

[TXT]

 magicolor1600Wmanuel..> 28-Sep-2012 12:41  317K  

[TXT]

 samsung-Wave-II-noir..> 28-Sep-2012 13:46  3.3M 

Dell PowerEdge RAID Controller (PERC) S100, PERC S300 Guide d'utilisationRemarques, précautions et avertissements REMARQUE : Une REMARQUE indique des informations importantes qui peuvent vous aider à mieux utiliser votre ordinateur. PRÉCAUTION : Une PRÉCAUTION indique un risque d'endommagement du matériel ou de perte de données en cas de non respect des instructions. AVERTISSEMENT : Un AVERTISSEMENT indique un risque d'endommagement du matériel, de blessures corporelles ou même de mort. ____________________ Les informations contenues dans cette publication sont sujettes à modification sans préavis. © 2008—2011 DellInc. Tous droits réservés. La reproduction de ce document de quelque manière que ce soit sans l'autorisation écrite de Dell Inc. est strictement interdite. Marques utilisées dans ce document : Dell™, le logo DELL, PowerEdge™ et OpenManage™ ont des marques de Dell Inc. Intel™ est une marque déposée d'Intel Corporation aux États-Unis et dans d'autres pays. AMD® est une marque déposée et AMD Opteron™, AMD Phenom™ et AMD Sempron™ sont des marques d'Advanced Micro Devices, Inc. Microsoft®, Windows® et Windows Server® sont des marques ou des marques déposées de Microsoft Corporation aux États-Unis et/ou dans d'autres pays. D'autres marques et noms commerciaux peuvent être utilisés dans ce document pour faire référence aux entités revendiquant la propriété de ces marques ou de ces noms de produits. Dell Inc. rejette tout intérêt propriétaire dans les marques et les noms commerciaux autres que les siens. Modèles : UCS61, UCS60 Février 2011 Rév. A01Table des matières 3 Table des matières 1 AVERTISSEMENT : consignes de sécurité . . . . . . . . . . . . . . . . . . . . . . . . 7 SÉCURITÉ : informations générales . . . . . . . . . . . . 8 SÉCURITÉ : intervention à l'intérieur de votre système . . . . . . . . . . . . . . . . . . . . . . . 8 Protection contre les décharges électrostatiques . . . . 9 2 Présentation . . . . . . . . . . . . . . . . . . . . . . 11 Introduction . . . . . . . . . . . . . . . . . . . . . . . 11 Généralités, public visé et conditions préalables à l'utilisation. . . . . . . . . . . . . . . . . . . . . . . 11 Documentation connexe. . . . . . . . . . . . . . . . . 12 Descriptions du contrôleur PERC S100 ou PERC S300 . . . . . . . . . . . . . . . . . . . . . . . . 12 À propos de RAID . . . . . . . . . . . . . . . . . . . . 17 Terminologie RAID. . . . . . . . . . . . . . . . . . . . 18 3 Fonctionnalités . . . . . . . . . . . . . . . . . . . . 21 Généralités. . . . . . . . . . . . . . . . . . . . . . . . 21 Caractéristiques . . . . . . . . . . . . . . . . . . . . . 324 Table des matières 4 Installation du matériel . . . . . . . . . . . . . 35 Avant de commencer. . . . . . . . . . . . . . . . . . . 35 Généralités . . . . . . . . . . . . . . . . . . . . . . . . 35 Installation du contrôleur PERC S300 . . . . . . . . . . 36 Connexion de disques physiques au contrôleur PERC S300 . . . . . . . . . . . . . . . . . . . . . . . . 39 Terminer l'installation du matériel . . . . . . . . . . . 39 5 Installation des pilotes . . . . . . . . . . . . . 41 Installation des pilotes Microsoft Windows . . . . . . 41 6 Configuration et gestion de RAID . . . . . 53 Configuration du contrôleur : utilisation de l'utilitaire de gestion de disques virtuels PERC . . . . . . . . . . 53 7 Dépannage. . . . . . . . . . . . . . . . . . . . . . . 67 Problèmes de démarrage du système . . . . . . . . . . 68 Messages d'avertissement : contrôleur Dell Inc. PERC S100 ou Dell Inc. PERC S300 Écran du BIOS . . . 71 Erreurs liées aux disques virtuels. . . . . . . . . . . . 79 Erreurs liées aux disques physiques . . . . . . . . . . 85 8 Annexe A . . . . . . . . . . . . . . . . . . . . . . . . 89 Caractéristiques du contrôleur . . . . . . . . . . . . . 89 Tâches du contrôleur . . . . . . . . . . . . . . . . . . 90Table des matières 5 Tâches des disques physiques . . . . . . . . . . . . . 90 Tâches des disques virtuels. . . . . . . . . . . . . . . 91 Niveaux de RAID pris en charge . . . . . . . . . . . . 92 Caractéristiques des disques virtuels. . . . . . . . . . 92 9 Annexe B . . . . . . . . . . . . . . . . . . . . . . . . . 95 Technologie RAID - Présentation des matrices de disques et des disques virtuels . . . . . . . . . . . 95 10 Annexe C . . . . . . . . . . . . . . . . . . . . . . . . 103 Avis réglementaires . . . . . . . . . . . . . . . . . . . 103 avis de la FCC (États-Unis uniquement). . . . . . . . . 105 Industry Canada (Canada uniquement) . . . . . . . . . 106 Avis CE (Union européenne). . . . . . . . . . . . . . . 107 Avis sur la marque CE . . . . . . . . . . . . . . . . . . 108 11 Annexe D . . . . . . . . . . . . . . . . . . . . . . . . 109 Contacter Dell . . . . . . . . . . . . . . . . . . . . . . 109 Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111 Glossaire . . . . . . . . . . . . . . . . . . . . . . . . . . . 1176 Table des matièresAVERTISSEMENT : consignes de sécurité 7 AVERTISSEMENT: consignes de sécurité Respectez les consignes de sécurité ci-après pour assurer votre sécurité personnelle, et pour protéger votre système et votre environnement de travail de dommages potentiels. AVERTISSEMENT : n'exposez pas le contrôleur Dell PowerEdge RAID Controller (PERC) S300 à des liquides. Pour réduire les risques d'incendie, ne couvrez pas et n'obstruez pas les entrées d'air du système sur lequel il est installé. N'installez pas le contrôleur dans un endroit confiné. Il pourrait surchauffer. AVERTISSEMENT : ne faites pas fonctionner le contrôleur s'il est tombé ou s'il est endommagé. AVERTISSEMENT : le contrôleur, comme toutes les autres pièces électroniques du système, risque d'être endommagé par l'électricité statique. Veillez à vous relier à la terre. Il est recommandé de porter un bracelet antistatique relié à la terre et de débrancher le système avant d'installer le contrôleur. PRÉCAUTION : les connecteurs de câble doivent être correctement connectés aux connecteurs du contrôleur PERC S300. Les connecteurs sont munis d'un détrompeur pour les empêcher d'être introduits incorrectement. PRÉCAUTION : assurez-vous que le contrôleur RAID actuel (s'il y en a un) n'a pas de tâches en suspens (telles qu'une reconstruction) avant de le mettre hors tension pour mettre le système à niveau. PRÉCAUTION : au cours d'une mise à jour micrologicielle, n'amorcez pas le système qui contient le contrôleur PERC S300. Une mise à jour peut prendre jusqu'à cinq minutes par contrôleur. 8 AVERTISSEMENT : consignes de sécurité SÉCURITÉ : informations générales Respectez et suivez les marquages d'entretien : • N'effectuez pas la maintenance d'un produit vous-même, sauf si vous suivez les explications fournies dans le manuel d'utilisation. Le fait d'ouvrir ou de retirer des caches portant un symbole en forme de triangle entourant un éclair risque de vous exposer à une décharge électrique. Seuls les techniciens de maintenance qualifiés sont habilités à manipuler les composants à l'intérieur de ces boîtiers. • N'utilisez le produit qu'avec du matériel agréé par Dell. • Ne faites fonctionner le produit qu'avec une source d'alimentation externe conforme aux indications figurant sur l'étiquette des normes électriques. Si vous n'êtes pas certain du type de source d'alimentation requis, adressezvous à votre prestataire de services ou à votre compagnie d'électricité. SÉCURITÉ : intervention à l'intérieur de votre système Avant de retirer les capots du système, suivez les étapes ci-dessous dans l'ordre indiqué. AVERTISSEMENT : seuls les techniciens formés sont autorisés par Dell à retirer les caches du système et à accéder à tous les composants internes, sauf mention contraire dans la documentation Dell. PRÉCAUTION : pour éviter tout dommage à la carte système, patientez cinq secondes après la mise hors tension du système avant de déconnecter le contrôleur. 1 Éteignez le système et tous ses périphériques. 2 Mettez des bracelets correctement mis à la terre avant de toucher l'intérieur du système. 3 Répétez cette opération régulièrement pendant votre intervention pour dissiper toute électricité statique qui pourrait endommager les composants internes.AVERTISSEMENT : consignes de sécurité 9 4 Débranchez votre système et vos périphériques de leur source d'alimentation. Pour éviter de vous blesser ou de recevoir une décharge électrique, débranchez toutes les lignes de télécommunication du système. De plus, gardez à l'esprit les consignes de sécurité suivantes qui s'appliquent à votre cas : • Lorsque vous débranchez un câble, tirez sur le connecteur ou sur la boucle prévue à cet effet, mais jamais sur le câble lui-même. Certains câbles sont munis de connecteurs à pattes de verrouillage. Si vous débranchez ce type de câble, appuyez sur les pattes de verrouillage avant de débranchez le câble. Quand vous séparez les connecteurs en tirant dessus, veillez à les maintenir alignés pour ne pas plier de broches. De même, lorsque vous connectez un câble, assurez-vous que les deux connecteurs sont bien orientés et alignés. • Manipulez le contrôleur avec précaution. Ne touchez pas les pièces ou les contacts du contrôleur. Protection contre les décharges électrostatiques Les décharges électrostatiques peuvent endommager les composants électroniques de votre système. Les ESD, ou les décharges électrostatiques, sont produites par l'accumulation d'électricité statique dans le corps d'une personne ou dans un objet, et par son déchargement dans un autre objet. Les décharges électrostatiques peuvent endommager votre contrôleur PERC S300, votre système, ainsi que d'autres composants électriques. Pour éviter les dommages causés par les décharges électrostatiques, il est conseillé que vous déchargiez votre corps de son électricité statique avant de manipuler les composants électroniques internes de votre système. Pour cela, touchez un objet en métal relié à la terre (par exemple, la surface métallique non peinte du panneau d'E/S du système) avant de manipuler tout élément électronique. En outre, lorsque vous manipulez les composants internes de l'ordinateur, pensez à toucher régulièrement un connecteur d'entrée/sortie pour vous débarrasser de la charge statique accumulée par votre corps.10 AVERTISSEMENT : consignes de sécurité Vous pouvez aussi prendre les mesures suivantes pour éviter les dommages liés aux décharges électrostatiques : • Lorsque vous déballez votre contrôleur de son carton, ne le retirez pas de son emballage antistatique tant que vous n'êtes pas prêt à l'installer. Juste avant de retirer l'emballage antistatique, déchargez bien l'électricité statique accumulée dans votre organisme. • Manipulez tous les composants sensibles aux décharges électrostatiques dans une zone protégée contre l'électricité statique. Dans la mesure du possible, utilisez des tapis de sol et des surfaces de travail antistatiques.Présentation 11 Présentation Introduction Le contrôleur Dell PowerEdge RAID Controller(PERC) S300 offre une solution RAID logicielle intégrée pour les serveurs Dell PowerEdge Value. Les contrôleurs PERC S300 prennent en charge les interfaces SAS et SATA. Le contrôleur PERC S300, équipé de deux connecteurs internes munis de quatre ports chacun, contient huit ports pour les lecteurs de connexion dotés d'une vitesse de démarrage maximale de jusqu'à 3 Gb/s par port. Le contrôleur PERC S100 est conçu pour être une solution RAID économique pour les serveurs Dell PowerEdge Value. La solution contrôleur PERC S100 prend en charge les disques durs SATA (HDD) et les lecteurs SSD. Le contrôleur PERC S100 n'exige aucun matériel supplémentaire ; il s'exécute à partir du jeu de puces ICH ou PCH sur la carte mère de la plateforme. Le contrôleur PERC S100 et le contrôleur PERC S300 offrent les mêmes prise en charge et fonctionnalité de niveau de RAID, notamment la prise en charge de jusqu'à 8 lecteurs physiques. Généralités, public visé et conditions préalables à l'utilisation Ce document fournit des informations sur : • Le contrôleur PERC S100 et le contrôleur PERC S300, notamment la prise en charge du serveur, du système d'exploitation et du logiciel • La configuration du contrôleur et les procédures de démarrage • Les modes de fonctionnement du contrôleur Ce document a été conçu pour être utilisé par les administrateurs système et techniciens familiarisés avec l'installation et la configuration de système de stockage.12 Présentation La configuration et l'utilisation du contrôleur supposent que vous soyez familiarisé avec : • Les serveurs et les réseaux informatiques • La technologie RAID • La technologie d'interface de stockage, telle que SAS et SATA Documentation connexe Pour de plus amples informations sur le contrôleur PERC S100 ou le contrôleur PERC S300 et leur relation avec la documentation Dell OpenManage Server Administrator Storage Management, reportez-vous à la documentation Storage Management disponible sur le site Web de support Dell à l'adresse support.dell.com/manuals. Descriptions du contrôleur PERC S100 ou PERC S300 La liste suivante présente chaque type de contrôleur : • Le contrôleur PERC S300 contient deux connecteurs internes munis de ports SAS x4. • Le modulaire PERC S300 contient deux connecteurs internes munis de ports SAS x4. • Le contrôleur PERC S100 s'exécute sur le jeu de puces ICH ou PCH de la carte mère de la plate-forme.Présentation 13 Plate-formes prises en charge Tableau 2-1. Systèmes Dell et matrice de support pour le contrôleur PERC S100 et le contrôleur PERC S300 Serveur PowerEdge Contrôleur PERC, avec prise en charge de jeu de puces et d'adaptateur par plate-forme PowerEdge R210 contrôleur PERC S100 – Jeux de puces Intel Ibex Peak contrôleur PERC S300 – Contrôleur Dell 3 Gb/s SAS PowerEdge R210 II contrôleur PERC S100 – Jeux de puces Intel Cougar Point contrôleur PERC S300 – Contrôleur Dell 3 Gb/s SAS PowerEdge R310 contrôleur PERC S100 – Jeux de puces Intel Ibex Peak contrôleur PERC S300 – Contrôleur SAS Dell 3 Gb/s modulaire PowerEdge R410 contrôleur PERC S100 – Jeux de puces Intel ICH10R contrôleur PERC S300 – Contrôleur SAS Dell 3 Gb/s modulaire PowerEdge R415 contrôleur PERC S300 – Contrôleur SAS Dell 3 Gb/s modulaire jeux de puces AMD SP5100 South Bridge PowerEdge R510 contrôleur PERC S100 – Jeux de puces Intel ICH10R contrôleur PERC S300 – Contrôleur Dell 3 Gb/s SAS PowerEdge R515 contrôleur PERC S300 – Contrôleur Dell 3 Gb/s SAS jeux de puces AMD SP5100 South Bridge PowerEdgeT110 contrôleur PERC S100 – Jeux de puces Intel Ibex Peak contrôleur PERC S300 – Contrôleur Dell 3 Gb/s SAS PowerEdge T110 II contrôleur PERC S100 – Jeux de puces Intel Cougar Point contrôleur PERC S300 – Contrôleur Dell 3 Gb/s SAS PowerEdgeT310 contrôleur PERC S100 – Jeux de puces Intel Ibex Peak contrôleur PERC S300 – Contrôleur Dell 3 Gb/s SAS PowerEdgeT410 contrôleur PERC S100 – Jeux de puces Intel ICH10R contrôleur PERC S300 – Contrôleur Dell 3 Gb/s SAS14 Présentation Exigences de plate-forme pour les contrôleurs PERC S100 et PERC S300 Tableau 2-2. Exigences de plate-forme — Contrôleur PERC S100 ou PERC S300 Composant Exigences Processeur Processeur x86, 32 bits compatible supérieur à 500 MHz. Mémoire 512 Mo ou supérieur. Disque physique Au moins un lecteur HDD (Hard Disk Drive - Lecteur de disque dur) ou SSD (Solid State Disk Drive - Lecteur de disque à circuits intégrés). REMARQUE : le contrôleur PERC S100 prend en charge les configurations câblées de jusqu'à 4 disques physiques HDD SATA ou 4 disques physiques SDD SATA. Le contrôleur PERC S300 prend en charge les configurations câblées ou remplaçables à chaud jusqu'à 8 disques physiques HDD SATA ou SAS. • Les disques physiques HDD SATA-II peuvent être utilisés avec le contrôleur PERC S100 ou le contrôleur PERC S300. • Les disques physiques SSD SATA-II peuvent être utilisés uniquement avec le contrôleur PERC S100. • Les disques physiques HDD SAS peuvent être utilisés uniquement avec le contrôleur PERC S300. Ports • La carte adaptatrice S300 dispose de deux connecteurs SAS internes de type 8470. Chaque mini-connecteur SAS prend en charge 4 ports SAS/SATA. • Le contrôleur S300 modulaire se branche habituellement sur un fond de panier qui dispose d'un connecteur SAS de type 8470 (sauf pour le contrôleur PERC S300 sur un R210 ou T110, dont les câbles se branchent directement sur les disques physiques). Logements disponibles Le contrôleur PERC S300 et les cartes modulaires PERC S300 s'enclenchent dans les logements correspondants PCI-E (Peripheral Component Interconnect - Interconnexion de composants périphériques) à 8 voies.Présentation 15 Systèmes d'exploitation • Microsoft Windows Essential Business Server (x64) • Microsoft Windows Server 2008, Édition Datacenter (x64) • Microsoft Windows Server 2008, Édition Enterprise (x64) • Microsoft Windows Server 2008, Édition Enterprise (x86) • Microsoft Windows Server 2008 Foundation • Microsoft Windows Server 2008, Édition HPC • Microsoft Windows Server 2008 R2 Datacenter • Microsoft Windows Server 2008 R2 SP1 • Microsoft Windows Server 2008 R2 Entreprise • Microsoft Windows Server 2008 R2 Entreprise SP1 • Microsoft Windows Server 2008 R2 Foundation • Microsoft Windows Server 2008 R2 Foundation?SP1 • Microsoft Windows Server 2008 R2, Édition HPC • Microsoft Windows Server 2008 R2 Standard. • Microsoft Windows Server 2008 R2 Standard SP1 • Microsoft Windows Server 2008 SP2, Édition Datacenter (x64) • Microsoft Windows Server 2008 SP2, Édition Enterprise (x64) • Microsoft Windows Server 2008 SP2, Édition Enterprise (x86) • Microsoft Windows Server 2008 SP2, Édition Standard (x64) • Microsoft Windows Server 2008 SP2, Édition Standard (x86) • Microsoft Windows Server 2008 SP2, Édition Web (x64) • Microsoft Windows Server 2008 SP2, Édition Web (x86) • Microsoft Windows Server 2008, Édition Standard (x64) • Microsoft Windows Server 2008, Édition Standard (x86) • Microsoft Windows Server 2008 R2, 64 bits, Édition Standard et Entreprise • Microsoft Windows Server 2008 64 bits version Web Tableau 2-2. Exigences de plate-forme — Contrôleur PERC S100 ou PERC S300 (suite) Composant Exigences16 Présentation • Microsoft Windows Server 2008, Édition Web (x64) • Microsoft Windows Server 2008, Édition Web (x86) • Microsoft Windows Small Business Server 2008 • Microsoft Windows Small Business Server 2008 SP2. • Microsoft Windows Small Business Server 2003 R2 SP2 (x86 ou x64) • Microsoft Windows Small Business Server 2011 • Microsoft Windows Web Server 2008 R2 • Microsoft Windows Web Server 2008 R2 SP1 • Microsoft Windows Server 2003 SP2 (x86 ou x64) • Microsoft WindowsServer 2003 R2 SP2, 32 bits ou 64 bits, Édition Standard et Entreprise • Microsoft Windows Server 2003 R2 SP2 32 bits Édition Web • Microsoft Windows Server 2008 SP2, 32 bits ou 64 bits, Édition Standard et Entreprise. REMARQUE : Microsoft Windows Server 2003 SP1 n'est pas pris en charge. REMARQUE : Microsoft Windows Server 2003 R2 n'est pas pris en charge. REMARQUE : les contrôleurs PERC S100 et PERC S300 ne sont pas pris en charge avec Windows Hyper-V. Périphériques pris en charge • contrôleur PERC S100 : prend en charge les périphériques de bande SATA et les périphériques de disque optique SATA pris en charge par Dell. REMARQUE : le contrôleur PERC S100 prend en charge l'amorçage du système sur une bande, à l'aide d'un périphérique de bande Dell RD1000. Sélectionnez Continuer tout en appuyant sur CTRL-R pour que RD1000 reste en première position dans l'ordre d'amorçage. L'option RD1000 met fin à l'ordre d'amorçage si est sélectionné, et il vous sera impossible d'effectuer l'amorçage dessus. • contrôleur PERC S300 : ne prend pas en charge les périphériques de bande ou les périphériques de disque optique SATA. Tableau 2-2. Exigences de plate-forme — Contrôleur PERC S100 ou PERC S300 (suite) Composant ExigencesPrésentation 17 À propos de RAID Le terme RAID désigne un groupe de plusieurs disques physiques indépendants qui permet d'optimiser les performances en augmentant le nombre de disques utilisés pour l'accès aux données et leur enregistrement. Un sous-système de disque RAID améliore les performances des entrées/sorties et la disponibilité des données. Les disques physiques sont identifiés par le système hôte sous la forme d'une seule unité de stockage ou de plusieurs unités logiques. Le débit de données augmente, car le système accède simultanément à plusieurs disques. Les systèmes RAID améliorent également la disponibilité du système de stockage ainsi que la tolérance aux pannes. Les données perdues en raison d'une panne d'un disque physique peuvent être restaurées en reconstruisant les données manquantes à partir des autres disques physiques, qui contiennent des données ou des informations de parité. REMARQUE : lorsqu'un disque physique d'un disque virtuel RAID 0 est défectueux, les données sont perdues car ce niveau de RAID ne dispose pas de la redondance des données. En revanche, lorsqu'un disque physique est défectueux dans RAID 1, RAID 5 ou RAID 10, les données sont préservées car ces niveaux de RAID permettent la redondance des données. Récapitulatif des niveaux de RAID • Le volume utilise l'espace disponible sur un seul disque physique et forme un seul volume logique sur lequel les données sont stockées. • Le niveau de RAID 0 utilise la répartition (striping) des données sur plusieurs disques pour accélérer le débit de données, notamment pour les fichiers volumineux, dans les environnements ne nécessitant pas de redondance des données. • Le niveau de RAID 1 exploite la mise en miroir des disques afin d'écrire les données simultanément sur deux disques physiques. Il est particulièrement adapté aux bases de données de petite taille ou aux applications peu gourmandes en ressources, mais nécessitant une redondance totale des données. • Le niveau RAID 5 combine répartition sur disque et stockage de données de parité sur tous les disques physiques (parité distribuée) afin de fournir un haut débit et une redondance des données. • Le RAID 10 utilise la répartition sur disque sur deux ensembles mis en miroir. Il fournit un haut débit et une redondance totale des données. 18 Présentation Terminologie RAID Répartition sur les disques La répartition, ou striping, permet d'écrire des données sur plusieurs disques physiques au lieu d'un seul. La répartition sur les disques comprend le partitionnement de chaque espace de stockage de disque physique en bandes de différentes tailles. Ces bandes sont entrelacées de manière séquentielle. La partie de la bande qui se trouve sur un seul disque physique est appelée « élément de bande ». Par exemple, dans un système à quatre disques qui utilise uniquement la répartition sur disque (dans RAID 0), le segment 1 est écrit sur le disque 1, le segment 2 est écrit sur le disque 2, etc. La répartition sur les disques améliore les performances, car le système peut accéder simultanément à plusieurs disques physiques, mais elle ne fournit aucune redondance des données. La Figure 2-1 montre un exemple de répartition sur les disques. Figure 2-1. Exemple d'utilisation de la répartition (RAID0) Élément de bande 1 Élément de bande 5 Élément de bande 9 Élément de bande 2 Élément de bande 6 Élément de bande 10 Élément de bande 3 Élément de bande 7 Élément de bande 11 Élément de bande 4 Élément de bande 8 Élément de bande 12Présentation 19 Mise en miroir des disques Avec la mise en miroir des disques, ou mirroring, (comme avec RAID 1), les données écrites sur un disque sont simultanément écrites sur un autre. En cas de panne d'un disque, le contenu de l'autre peut servir à faire fonctionner le système et à reconstruire le disque physique défectueux. L'avantage principal de la mise en miroir des disques est la redondance totale des données. Comme le contenu du premier disque est intégralement dupliqué sur le second, l'un des deux disques peut tomber en panne sans que cela ait de conséquence. Les deux disques contiennent une copie des mêmes données en permanence. Chacun des deux peut jouer le rôle de disque physique opérationnel. La mise en miroir fournit une redondance totale des données mais coûte cher car il devient nécessaire de dupliquer chaque disque physique du système. La Figure 2-2 montre un exemple de mise en miroir des disques. REMARQUE : la mise en miroir améliore les performances de lecture grâce à l'équilibrage de charge. REMARQUE : le contrôleur PERC S300 prend uniquement en charge les disques physiques (SAS et SATA). Les périphériques SSD ne peuvent pas être migrés sur un contrôleur PERC S300. Figure 2-2. Exemple de mise en miroir des disques (RAID1) Niveaux de RAID avec fractionnement sur plusieurs disques Le terme fractionnement (spanning) décrit la manière dont le RAID 10 est construit à partir de plusieurs ensembles de RAID de niveau plus simple. Par exemple, une installation RAID 10 est constituée de plusieurs ensembles de matrices RAID 1, chaque ensemble RAID 1 étant considéré comme un élément du fractionnement. Les données sont ensuite réparties (comme pour RAID 0) sur plusieurs ensembles RAID 1 pour créer un disque virtuel RAID 10. Élément de bande 1 Élément de bande 2 Élément de bande 3 Élément de bande 1 dupliqué Élément de bande 2 dupliqué Élément de bande 3 dupliqué Élément de bande 4 Élément de bande 4 dupliqué20 Présentation Données de parité Les données de parité sont des données redondantes générées afin de fournir une tolérance de pannes pour certains niveaux de RAID. En cas de panne d'un disque, le contrôleur peut utiliser les données de parité pour régénérer les données utilisateur. Les données de parité sont uniquement présentes dans les matrices de disques RAID 5. Ces données sont réparties sur tous les disques physiques du système. En cas d'échec d'un seul disque physique, vous pouvez le reconstruire à partir de la parité et des données figurant sur les autres disques physiques. RAID 5 combine répartition sur les disques et parité distribuée, tel qu'illustré dans la Figure 2-3. La parité fournit la redondance nécessaire pour faire face à une panne d'un seul disque physique sans dupliquer l'intégralité du contenu des disques physiques. Figure 2-3. Exemple de parité distribuée (RAID 5) Élément de bande 1 Élément de bande 7 Élément de bande 2 Élément de bande 8 Élément de bande 3 Élément de bande 9 Élément de bande 4 Élément de bande 10 Élément de bande 5 Parité (6 à 10) Parité (11 à 15) Parité (1 à 5) Élément de bande 6 Élément de bande 12 Élément de bande 15 Élément de bande 11 Élément de bande 13 Élément de bande 14 Élément de bande 19 Élément de bande 25 Élément de bande 20 Élément de bande 23 Élément de bande 18 Élément de bande 21 Élément de bande 16 Élément de bande 22 Élément de bande 17 Parité (21 à 25) Parité (26 à 30) Parité (16 à 20) Élément de bande 24 Élément de bande 30 Élément de bande 27 Élément de bande 29 Élément de bande 26 Élément de bande 28Features 21 Fonctionnalités Généralités Les fonctionnalités du contrôleur Dell PowerEdge RAID Controller (PERC) S100 et du contrôleur PERC S300 sont décrites dans le Tableau 3-1. REMARQUE : BAS, BGI, CC et OCE s'exécutent uniquement sur le système d'exploitation. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 Fonctionnalité de contrôleur RAID Description Reconstruction automatique du disque virtuel Reconstruit un disque virtuel redondant automatiquement lorsqu'une panne est détectée, si un disque de secours est affecté. Balayage de la matrice en arrière-plan (Background Array Scan - BAS) Vérifie et corrige les erreurs de support corrigibles des données en miroir, de volume ou de parity des disques virtuels. BAS s'exécute automatiquement après la création d'un disque virtuel dans le système d'exploitation.22 Fonctionnalités Initialisation en arrière-plan du disque virtuel (Background virtual disk initialization - BGI) L'initialisation en arrière-plan d'un disque virtuel redondant crée des données de parité qui permettent au disque virtuel de maintenir la redondance des données et de survivre à la panne d'un disque physique. L'initialisation en arrière-plan s'apparente au contrôle de cohérence, en ce qu'elle permet au contrôleur d'identifier et de corriger des problèmes de redondance des données qui pourraient survenir dans le futur. L'initialisation en arrière-plan permet à un disque virtuel redondant d'être immédiatement utilisable. Les données sont perdues si un disque physique tombe en panne avant la fin d'une BGI. REMARQUE : même si la BGI est générée par le logiciel dans l'utilitaire PERC Virtual Disk Management, les pilotes de contrôleur PERC S100/contrôleur PERC S300 doivent être chargés avant d'exécuter la BGI. REMARQUE : sauf mention contraire, le terme utilitaire de gestion de disques virtuels PERC englobe l'utilitaire PERC S100 Virtual Disk Management et l'utilitaire PERC S300 Virtual Disk Management. Prise en charge au démarrage pour les niveaux de RAID Permet la prise en charge au démarrage pour les volumes, RAID 0, RAID 1, RAID 5 et RAID 10. Prise en charge au démarrage pour les disques virtuels dégradés Permet au système de démarrer à partir de disques virtuels redondants dégradés (RAID 1, RAID 5 ou RAID 10). Prise en charge de la cache pour les disques virtuels Prend en charge les options de cache suivantes : Aucune, Lecture seule, Lecture/Écriture. Le contrôleur PERC S100 ou le contrôleur PERC S300 utilise une partie de la mémoire système pour la cache. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID DescriptionFeatures 23 Point de contrôle Permet différents types de points de contrôle (initialisation en arrière-plan, contrôle de cohérence et reconstruction) pour reprendre au dernier point après le démarrage. Une fois le système démarré, cette fonction en arrière-plan reprend à son point de contrôle le plus récent. File d'attente de commandes La file d'attente de commandes est un protocole de commande des disques physiques SATA et SAS pris en charge par le contrôleur PERC S100 et le contrôleur PERC S300. La file d'attente de commandes permet à l'hôte d'émettre plusieurs demandes d'E/S à un disque simultanément. Le disque peut ensuite décider de l'ordre dans lequel il traitera les commandes pour des performances optimales. Les versions SATA et SAS de la file d'attente de commandes ont des protocoles et des moyens légèrement différents de traiter plusieurs demandes de trafic simultanément, mais leurs fins sont comparables. Vérification de cohérence (Consistency check - CC) La vérification de cohérence est une opération en arrière-plan qui vérifie et corrige les données de mise en miroir ou de parité des disques physiques avec tolérance de pannes. Il est recommandé d'exécuter régulièrement une vérification de cohérence sur les disques physiques. Par défaut, la vérification de cohérence corrige automatiquement les incohérences des données de mise en miroir et de parité. Une fois les données corrigées, les données du disque physique principal d'un ensemble mis en miroir sont supposées être correctes et sont écrites sur le deuxième disque physique de l'ensemble mis en miroir. Une vérification de cohérence ne peut pas être initiée par l'utilisateur dans l'utilitaire de gestion de disques virtuels PERC. Toutefois, une vérification de cohérence peut être initiée par l'utilisateur dans Dell OpenManage Server Administrator Storage Management. Initialisation de disques Pour les disques physiques, l'initialisation écrit les méta données sur le disque physique de sorte que le contrôleur puisse utiliser le disque physique. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID Description24 Fonctionnalités Tolérance aux pannes Les fonctionnalités de tolérance aux pannes suivantes sont disponibles dans le contrôleur PERC S100 et le contrôleur PERC S300, afin de prévenir une perte de données en cas de panne de disque physique : • Détection des pannes des disques physiques (automatique). • Reconstruction du disque virtuel à l'aide de disques de secours (automatique, si le disque de secours est configuré pour cette fonctionnalité). • Génération et contrôle de parité (RAID 5 uniquement). • Remplacement manuel à chaud d'un disque physique sans redémarrage du système (uniquement pour les systèmes munis d'un fond de panier qui permet le remplaçage à chaud). Si un côté d'un miroir RAID 1 tombe en panne, les données peuvent être reconstruites à l'aide du disque physique situé de l'autre côté du miroir. Si un disque physique RAID 5 tombe en panne, les données de parité existent sur les disques physiques restants, et peuvent être utilisées pour restaurer les données sur un nouveau disque physique de remplacement configuré en tant que disque de secours. Si un disque physique échoue dans RAID 10, le disque virtuel continue de fonctionner et les données sont lues à partir du/des disque(s) physique(s) mis en miroir restant(s). Une seule panne de disque dans chaque ensemble mis en miroir peut ne pas être critique, en fonction du type d'échec de l'ensemble mis en miroir. Reconstruction de l'ensemble mis en miroir Un ensemble mis en miroir brisé peut être reconstruit après l'insertion d'un nouveau disque physique et son affectation en tant que disque de secours. Le système n'a pas besoin d'un redémarrage. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID DescriptionFeatures 25 Extension de capacité en ligne (Online Capacity Expansion - OCE) L'OCE est un procédé qui vous permet d'ajouter de la capacité de stockage à un disque virtuel existant. Dans la plupart des cas la capacité de stockage supplémentaire peut être ajoutée sans mettre le système hors ligne. Toutefois, si un disque physique supplémentaire doit être ajouté et que le système ne prend pas en charge le remplaçage à chaud, le système doit être mis hors tension. L'OCE permet d'augmenter la capacité de stockage totale d'un disque virtuel en intégrant le stockage non utilisé sur le disque virtuel. L'accès aux données est possible lorsque les disques physiques sont ajoutés (si un système dispose de la capacité de remplaçage à chaud) et lorsque les données du disque virtuel sont en cours de redistribution. Pour les volumes et RAID 1, l'OCE étend le disque virtuel à l'aide de l'espace disponible sur les disques physiques qui sont déjà membres du disque virtuel. Pour RAID 0, RAID 5 et RAID 10, une capacité supplémentaire peut être obtenue en ajoutant des disques physiques au disque virtuel. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID Description26 Fonctionnalités Disques physiques (généralités) Le contrôleur PERC S100 prend en charge jusqu'à quatre disques physiques HDD ou SSD SATA. Le contrôleur PERC S300 prend en charge jusqu'à huit disques physiques HDD SATA ou SAS. REMARQUE : les disques physiques d'un disque virtuel doivent avoir la même interface et le même type de lecteur (HDD ou SSD). Par exemple, vous ne pouvez pas combiner des interfaces SATA et SAS (HDD ou SSD), ou des disques physiques HDD et SSD dans le même disque virtuel. Un maximum de huit disques physiques peut être utilisé pour RAID 0 et RAID 5. Un maximum de deux disques physiques peut être utilisé pour RAID 1. Un maximum de quatre disques physiques peut être utilisé pour RAID 10. Si un disque physique tombe en panne au cours du démarrage du système, le contrôleur identifie le disque physique en panne comme suit : • Dans l'utilitaire de gestion de disques virtuels PERC en mettant en surbrillance rouge le disque physique du disque virtuel en panne. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID DescriptionFeatures 27 • Par un bref avertissement dans l'écran du BIOS du contrôleur Dell Inc. PERC S100 ou du BIOS du contrôleur Dell Inc. PERC S300, qui signale qu'un disque virtuel Dégradé et/ou En échec/Défaillant a été détecté. Ce message prévient l'utilisateur que des disques physiques sont en échec. • Dans le gestionnaire de stockage Dell OpenManage Server Administrator. • Avec un voyant d'état bicolore sur chaque disque physique. La partie verte du voyant d'état est éteinte et la partie orange clignote. REMARQUE : le voyant d'état s'applique uniquement aux systèmes dotés d'un contrôleur PERC S300 et d'un fond de panier ayant des disques physiques amovibles. REMARQUE : les contrôleurs PERC S100 prennent en charge des disques physiques HDD d'une capacité de 2 To et supérieure. Les versions actuelles et ultérieures des contrôleurs PERC S300 ne prennent en charge que des disques physiques HDD d'une capacité de 2 To. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID Description28 Fonctionnalités Remplaçage à chaud de disques physiques (capacité de remplaçage à chaud) La fonctionnalité de remplaçage à chaud (enfichage à chaud) est la substitution manuelle d'un disque physique pour un autre lorsque le système hôte est sous tension. Si un système prend en charge le remplaçage à chaud, les disques physiques peuvent être branchés sur le fond de panier d'un système tandis que le contrôleur est en fonctionnement sans avoir besoin de le redéfinir. PRÉCAUTION : un disque physique peut être remplacé à chaud sur un système uniquement si ce système dispose d'un contrôleur PERC S300 et d'un fond de panier qui prend en charge le remplaçage à chaud. REMARQUE : si les disques physiques d'un système sont uniquement accessibles lorsque le capot du système est retiré, les disques physiques ne peuvent pas être remplacés à chaud. Les disques physiques doivent être situés sur le fond de panier (derrière le panneau avant amovible) et accessibles de l'extérieur. REMARQUE : lors du remplacement de disques physiques dans un disque virtuel déjà créé, veillez à ce que les disques physiques HDD SAS soient remplacés par des disques physiques HDD SAS, que les disques physiques HDD SATA soient remplacés par des disques physiques HDD SATA et que les disques physiques SSD SATA soient remplacés par des disques physiques SSD SATA. REMARQUE : lorsque vous remplacez des disques physiques à chaud, assurez-vous que le nouveau disque dispose d'une capacité supérieure ou égale au disque physique remplacé. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID DescriptionFeatures 29 Itinérance de disque physique Le contrôleur prend en charge le déplacement d'un disque physique d'un logement de fond de panier ou d'une connexion de câble à une autre (sur le même contrôleur). Le contrôleur reconnaît automatiquement le disque physique replacé et le place logiquement dans le bon ordre. AVERTISSEMENT : un disque virtuel est perdu si vous effectuez une itinérance de disques lorsqu'une OCE est en cours d'exécution dans le gestionnaire de stockage. REMARQUE : pour de plus amples informations sur l'ouverture du système et l'ajout de pièces, reportez-vous au Manuel du propriétaire disponible sur le site Web de support Dell à l'adresse support.dell.com/manuals. Procédez aux étapes suivantes pour l'itinérance des disques physiques : REMARQUE : ces étapes ne s'appliquent pas aux systèmes munis d'un fond de panier qui ne prend pas en charge le remplaçage à chaud. 1 Éteignez le système, les disques physiques et les composants système. 2 Débranchez les cordons d'alimentation du système. 3 Déplacez les disques physiques dans des logements différents du fond de panier ou modifiez leurs connexions câblées. 4 Effectuez un contrôle de sécurité. Assurez-vous que les disques physiques sont correctement insérés. 5 Connectez les câbles d'alimentation et mettez le système sous tension. REMARQUE : le contrôleur détecte la configuration RAID à partir des données de configuration figurant sur les disques physiques. Prise en charge du pilote du port de stockage (Storport) En l'utilisant avec Microsoft WindowsServer 2003 et les versions ultérieures, le pilote Storport optimise le débit de traitement et les interfaces de pilote miniport. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID Description30 Fonctionnalités Taille des bandes La taille des bandes est déterminée par un algorithme du contrôleur PERC S100/contrôleur PERC S300. La taille des bandes ne peut pas être configurée par l'utilisateur. Disques virtuels (généralités) Jusqu'à huit disques virtuels sont pris en charge. Le contrôleur PERC S100 et le contrôleur PERC S300 permettent : • La création de disques virtuels dans différents niveaux de RAID sur un seul contrôleur. • La création de disques virtuels sur le même disque physique, pour adapter chaque disque virtuel aux E/S qu'il traite. • La construction de différents disques virtuels avec des caractéristiques différentes pour des applications différentes. Le contrôleur PERC S100 et le contrôleur PERC S300 ne permettent pas : • La création d'un disque virtuel à partir d'une combinaison de disques physiques de types différents. Par exemple, un disque virtuel dans RAID 10 ne peut pas être créé à partir de deux disques physiques HDD SATA II, un disque physique HDD SAS et un disque physique SSD. Tous les disques physiques doivent avoir la même interface (SAS ou SATA) et le même type de lecteur (HDD ou SSD). • La sélection d'un disque physique en tant que disque de secours dédié si le disque physique est d'un type différent du ou des disque(s) physique(s). Un disque virtuel est une zone de stockage créée par le contrôleur à partir d'un ou de plusieurs disques physiques. Bien qu'il soit possible de créer un disque virtuel à partir de plusieurs disques physiques, le système d'exploitation le reconnaît comme un seul disque. La capacité d'un disque virtuel peut être étendue en ligne pour tous les niveaux de RAID, sans redémarrer le système d'exploitation. Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID DescriptionFeatures 31 Migration de disques virtuels Le contrôleur prend en charge la migration automatique de disques virtuel d'un contrôleur PERC S100 à un contrôleur PERC S300 (ou vice versa). L'intervention manuelle pour la migration n'est pas requise ou utilisée par le contrôleur PERC S100 ou le contrôleur PERC S300. PRÉCAUTION : avant de démarrer la migration d'un disque virtuel, mettez les deux systèmes hors tension avant de retirer ou d'insérer les disques physiques. Une fois la migration terminée, assurez-vous que tous les disques physiques ont migré et sont présents sur le disque virtuel. PRÉCAUTION : le disque virtuel est perdu si vous effectuez la migration d'un disque virtuel au cours d'une OCE. REMARQUE : le contrôleur PERC S100 prend uniquement en charge les disques HDD SATA et SDD SATA. Les disques SAS ne peuvent pas migrer avec un contrôleur PERC S100. REMARQUE : un disque virtuel amorçable ne peut pas migrer entre des contrôleurs différents ou des modèles de systèmes différents lorsque le système utilise Microsoft Windows Server 2003 comme système d'exploitation. Niveaux de RAID des disques virtuels Des disques virtuels peuvent être créés à des niveaux de RAID différents. Transformation des disques virtuels La transformation d'un disque virtuel comprend les points suivants : • L'extension de la capacité, à l'aide de OCE (pour allouer de l'espace disque virtuel supplémentaire sur les disques physiques d'origine ou après l'ajout de disques physiques supplémentaires). • La reconstruction (la reconstruction des données sur un disque virtuel se fait à l'aide d'un disque de secours disponible ou d'un disque physique de sauvegarde). Tableau 3-1. Fonctionnalités du contrôleur PERC S100 ou PERC S300 (suite) Fonctionnalité de contrôleur RAID Description32 Fonctionnalités Caractéristiques Le Tableau 3-2 compare les spécifications du contrôleur PERC S100 et du contrôleur PERC S300. Tableau 3-2. Spécifications du contrôleur PERC S100 et du contrôleur PERC S300 Caractéristiques contrôleur PERC S100 contrôleur PERC S300 Technologie SAS Non Oui Technologie SATA Oui Oui Technologie eSATA Oui Non Technologie SSD Oui Non Prise en charge de l'interface hôte PCI-E x8 Non Oui Contrôleur d'E/S Intel ICH10R ou Jeux de puces Intel Ibex Peak ou Intel Cougar Point Contrôleur Dell 3Gb/s SAS Communication avec le système Intégrée Voies PCI-e Connexion aux périphériques finaux Liens SATA Liens SAS/SATA Connecteurs SAS Non Deux connecteurs à 4 ports sur tous les systèmes Connecteurs SATA Discrets sur la carte mère Deux connecteurs à 4 ports sur tous les systèmes Sans plomb Oui Oui Systèmes d'exploitation pris en charge Famille de serveurs Microsoft Windows Server 2003, famille de serveurs Microsoft Windows Server 2008, Microsoft Windows Server 2008 R2 Compatibilité SATA conforme Dell Oui Oui Compatibilité SAS conforme Dell Non OuiFeatures 33 *SMART est pris en charge sous le pilote Windows mais n'est pas pris en charge avec l'interface UEFI (Unified Extensible Firmware Interface de micrologiciel extensible unifiée) et CTRL-R. L'état du lecteur SWRAID SMART affiche « Dégradé » dans OpenManage Storage Services (OMSS). Périphériques finaux à connexion directe pris en charge par Dell Disques physiques compatibles Dell Disques physiques compatibles Dell Prise en charge des erreurs *SMART par les applications de gestion Oui Oui Systèmes pris en charge par le fond de panier Non Oui RAID basé sur logiciel Volume, RAID 1, RAID 0, RAID 5, RAID 10 Volume, RAID 1, RAID 0, RAID 5, RAID 10 Nombre maximal de disques virtuels 8 8 Prise en charge d'un lecteur de bande interne Oui Non Prise en charge du disque de secours global Oui Oui Nombre maximal de disques de secours Varie (en fonction du nombre de disques libres du système) Varie (en fonction du nombre de disques libres du système) Tableau 3-2. Spécifications du contrôleur PERC S100 et du contrôleur PERC S300 Caractéristiques contrôleur PERC S100 contrôleur PERC S30034 FonctionnalitésInstallation du matériel 35 Installation du matériel Avant de commencer Ce chapitre décrit l'installation du contrôleur Dell PowerEdge RAID Controller (PERC) S300. REMARQUE : le contrôleur PERC S100 fait partie intégrante de la carte mère. Les instructions d'installation du matériel ne sont pas requises pour un système équipé d'un contrôleur PERC S100. Généralités AVERTISSEMENT : avant de commencer une procédure de ce chapitre, suivez les consignes de sécurité fournies avec votre système. Pour des informations supplémentaires sur la sécurité, voir la page d'accueil sur la conformité aux réglementations sur le site dell à l'adresse suivante : dell.com/regulatory_compliance. AVERTISSEMENT : les décharges électrostatiques peuvent endommager des composants sensibles. Utilisez toujours une protection antistatique adaptée lorsque vous manipulez des composants. Un contact avec les composants sans mise à la terre correcte peut endommager votre équipement. AVERTISSEMENT : enfichez le contrôleur PERC S300 uniquement dans le logement PCI-E. Le fait de brancher le contrôleur dans le mauvais type de logement risque de l'endommager ainsi que la carte mère. PRÉCAUTION : avant d'installer un contrôleur dans un système existant, sauvegardez toutes les données critiques. Si vous ne vous conformez pas à cette pratique de gestion de système courante, vous risquez de perdre des données.36 Installation du matériel Installation du contrôleur PERC S300 REMARQUE : la procédure d'ouverture du système et d'ajout de pièces peut varier d'un système à l'autre. Pour de plus amples informations, reportez-vous au Manuel du propriétaire du matériel du système sur le site Web de support Dell à l'adresse support.dell.com/manuals. 1 Déballez le contrôleur PERC S300 et vérifiez qu'il est en bon état. REMARQUE : si le contrôleur PERC S300 est endommagé, contactez le support de Dell à l'adresse support.dell.com. 2 Éteignez le système et les périphériques qui y sont connectés. Déconnectez le câble d'alimentation système de la prise secteur. Voir le Manuel du propriétaire du matériel ou le Guide d’utilisation du système sur support.dell.com/manuals pour en savoir plus sur les blocs d'alimentation. 3 Déconnectez le système du réseau et retirez son capot. Reportez-vous au Manuel du propriétaire du matériel ou au Guide d’utilisation de votre système pour obtenir davantage d'informations sur son ouverture. 4 Sélectionnez un logement PCI-E approprié. Retirez la plaque de recouvrement, à l'arrière du système, qui correspond au logement PCI-E choisi. REMARQUE : insérez le contrôleur dans un logement doté d'au moins huit voies PCI-E pour des performances optimales. REMARQUE : insérez le contrôleur dans un logement PCI-E x8 ou un connecteur physique plus important. REMARQUE : pour en savoir plus sur les logements PCI-E de votre système, voir le Manuel du propriétaire du matériel ou Guide d’utilisation du système sur le site Web de support Dell à l'adresse support.dell.com/manuals. 5 Alignez le contrôleur PERC S300 sur le logement PCI-E choisi. 6 Insérez le contrôleur doucement, mais fermement dans le logement jusqu'à ce qu'il soit correctement emboîté. Voir la Figure 4-1. 7 Serrez la vis du support, s'il y en a une, ou utilisez les clips de retenue pour fixer le contrôleur au châssis du système. REMARQUE : si vous tentez d'installer un contrôleur PERC S300 modulaire, reportez-vous à la documentation de la plate-forme pour obtenir de l'aide.Installation du matériel 37 Figure 4-1. Installation d'un contrôleur PERC S300 1 vis du support 2 contrôleur PERC S300 3 logement PCI-E 4 plaque de recouvrement 5 support PCI 1 2 3 4 538 Installation du matériel Figure 4-2. Connexion des câbles 1 câbles des disques physiques (s'applique aux systèmes dotés d'un contrôleur PERC S300) ou des fonds de panier (s'applique uniquement aux systèmes dotés d'un contrôleur PERC S300 modulaire) 2 connecteurs internes SAS/SATA x4 (2) 3 contrôleur PERC S300 1 2 3Installation du matériel 39 Connexion de disques physiques au contrôleur PERC S300 AVERTISSEMENT : des composants critiques du système peuvent être endommagés si l'installateur n'est pas correctement mis à la terre pour prévenir les décharges électrostatiques (ESD). REMARQUE : utilisez le connecteur d'alimentation standard ou, s'il est disponible sur le bloc d'alimentation, un connecteur d'alimentation SATA/SATA II. Utilisez uniquement un de ces deux connecteurs. REMARQUE : les voyants de disque physique du système qui utilise un contrôleur PERC S300sont visibles lors du retrait du panneau avant du système. REMARQUE : le contrôleur prend en charge une fonction qui décale séquentiellement l'accélération de chaque disque physique. Cette fonction ménage suffisamment de temps entre chaque démarrage de disque physique pour éviter au bloc d'alimentation d'être en surcharge. 1 Installer les disques physiques dans le système. 2 Connectez un câble à plusieurs connecteurs à partir des disques physiques (ou du fond de panier) sur le contrôleur. REMARQUE : si le système comprend un contrôleur PERC S300 et un fond de panier remplaçable à chaud, les câbles ne peuvent pas être directement branchés sur les disques physiques. Les disques physiques (dans leur support) sont insérés et installés dans le fond de panier. Un câble du fond de panier est alors connecté au contrôleur PERC S300. Terminer l'installation du matériel Une fois le contrôleur et les câbles installés, procédez comme suit : 1 Assurez-vous que les groupes de fils et les câbles ne sont pas tordus à l'intérieur du système. Veillez à ce qu'ils ne bloquent pas les ventilateurs, les blocs d'alimentation, les dissipateurs de chaleur ou les appareils électriques. 2 Remettez en place le capot du système. Reportez-vous au Manuel du propriétaire du matériel ou au Guide d’utilisation de votre système pour obtenir davantage d'informations sur sa fermeture. 3 Reconnectez le ou les cordons d'alimentation et câbles réseau, puis mettez le système sous tension.40 Installation du matérielInstallation des pilotes 41 Installation des pilotes Le contrôleur Dell PowerEdge RAID Controller (PERC) S100 ou le contrôleur PERC S100 exige des pilotes de contrôleur qui fonctionnent avec les systèmes d'exploitation pris en charge. Ce chapitre présente les procédures d'installation des pilotes de contrôleur pour les systèmes d'exploitation suivants : • Microsoft WindowsServer 2008 • Microsoft Windows Server 2008 R2 • Microsoft Windows Server 2003 SP2 REMARQUE : Microsoft Windows Server 2003 R2 n'est pas pris en charge. Installation des pilotes Microsoft Windows Téléchargement du média de pilote de contrôleur 1 Rendez-vous sur le site support.dell.com/support/downloads. 2 Sélectionnez Choisir par numéro de service→ Saisir un numéro. 3 Saisissez le numéro de service du système sur lequel vous souhaitez installer les pilotes de contrôleur PERC S100/PERC S300, puis sélectionnez Go. REMARQUE : vous pouvez également sélectionner Choisir un modèle→ Sélectionner le modèle. Naviguez sur Serveurs, Stockage, Mise en réseau→Serveur PowerEdge. Sélectionnez le modèle de votre système, puis cliquez sur Confirmer. 4 Choisissez le système d'exploitation applicable. 5 Déroulez la catégorie contrôleur RAID SAS. 6 Sélectionnez Télécharger maintenant pour rechercher le pilote de contrôleur approprié. REMARQUE : introduisez un média optique vierge (CD-ROM ou DVD) dans votre système.42 Installation des pilotes 7 Gravez l'image ISO sur le média optique vierge. 8 Téléchargez les fichiers du contrôleur PERC S100 ou du contrôleur PERC S300 sur le support de pilote, comme indiqué dans la Figure 5-1. Conditions préalables à l'installation des pilotes de contrôleur • Assurez-vous que votre système est équipé des dernières mises à jour du BIOS et du micrologiciel disponibles sur le site Web de support de Dell à l'adresse support.dell.com/manuals. • Effectuez les procédures préalables à l'installation du Tableau 5-2 avant d'installer les pilotes de contrôleur et le système d'exploitation. • Lorsque vous êtes prêt à installer les pilotes de contrôleur et le système d'exploitation, voir « Installation des pilotes de contrôleur au cours de l'installation du système d'exploitation : pour les systèmes équipés d'un contrôleur PERC S100 », à la page 47 ou « Installation des pilotes de contrôleur au cours de l'installation du système d'exploitation : pour les systèmes équipés d'un contrôleur PERC S300 », à la page 49. Tableau 5-1. Système d'exploitation et média de pilote de périphérique Système d'exploitation Média de pilote (CD-ROM, DVD, lecteur flash USB ou disquette) à utiliser Windows Server 2008, Windows Server 2008 R2 32 bits ou 64 bits : copiez tous les fichiers sur un CD-ROM, DVD, lecteur flash USB ou disquette. Windows Server 2003 32 bits ou 64 bits : copiez tous les fichiers sur une disquette. REMARQUE : Windows Server 2003 version SP1 et ultérieure prend en charge le chargement de pilotes dans le cadre de l'installation du système d'exploitation à l'aide d'une clé USB.Installation des pilotes 43 Tableau 5-2. Conditions préalables à l'installation des pilotes de contrôleur Procédure Étapes 1 Confirmez et modifiez les paramètres de configuration dans la fenêtre Système Dell PowerEdge a Démarrez le système. Lorsque l'écran Dell Power-On Self-Test Controller (POST) apparaît, appuyez sur . b Patientez jusqu'à l'apparition de la fenêtre Système Dell PowerEdge. Effectuez les opérations suivantes, en fonction du contrôleur : • Pour un contrôleur PERC S100 : descendez jusqu'aux Paramètres SATA.Appuyez sur . Dans le sous-écran, confirmez que le contrôleur SATA est défini sur le mode RAID. REMARQUE : si nécessaire, modifiez le paramètre à l'aide de la barre d'espace. • Pour un contrôleur PERC S300 : descendez jusqu'aux Paramètres SATA. Appuyez sur . Dans le sous-écran, définissez le contrôleur SATA sur le mode ATA ou AHCI. REMARQUE : si nécessaire, modifiez le paramètre à l'aide de la barre d'espace. c Appuyez sur <Échap> pour quitter. d Appuyez de nouveau sur <Échap>. Les actions suivantes se produisent : • Si aucune modification n'a été effectuée à l'étape b, la séquence de démarrage se poursuit. • Si une modification a été effectuée à l'étape b, une boîte de dialogue s'affiche. Sélectionnez Enregistrer les modifications et quitter. Appuyez sur . La séquence de démarrage se poursuit. REMARQUE : si vous décidez de passer du contrôleur PERC S100 au contrôleur PERC S300, veillez également à modifier le paramètre dans Paramètres SATA→ Contrôleur SATA du mode RAID au modeATA. Voir l’étape b.44 Installation des pilotes 2 Installez le contrôleur PERC S300 (le cas échéant) Reportez-vous à la section « Installation du contrôleur PERC S300 » du Guide d'installation du matériel, situé sur le site web de support Dell à l'adresse support.dell.com/manuals. 3 Initialiser les disques physiques (le cas échéant) Voir « Initialisation des disques physiques », à la page 56. 4 Créer un disque virtuel amorçable Voir « Création de disques virtuels », à la page 58. Tableau 5-2. Conditions préalables à l'installation des pilotes de contrôleur (suite) Procédure Étapes Installation des pilotes 45 5 Vérifiez les options de contrôleur et la priorité de la liste d'amorçage a Dans l'utilitaire Utilitaire PERC S100 Virtual Disk Management ou Gestion de disques virtuels PERC S300 , utilisez les touches fléchées pour sélectionner les options de contrôleur. Appuyez sur . Assurez-vous que Toggle INT13 Boot Support (Basculer la prise en charge de l'amorçage INT13) est activé. Appuyez sur <Échap> pour quitter. b Dans le champ Disques virtuels, assurez-vous que le disque virtuel amorçable créé à l’étape 4 est le premier de la liste. Si le disque virtuel amorçable n'est pas le premier de la liste, voir « Permutation de deux disques virtuels », à la page 62. REMARQUE : si des disques virtuels non RAID sont utilisés (et apparaissent dans la liste des disques virtuels), l'option Swap Two Virtual Disks (Permuter deux disques virtuels) est uniquement activée si le système contient un disque physique initialisé. c Sélectionnez Continue to Boot (Continuer l'amorçage) et appuyez sur . REMARQUE : si la procédure suivante (6) n'est pas applicable, passez à l'une des procédures suivantes : • « Installation des pilotes de contrôleur au cours de l'installation du système d'exploitation : pour les systèmes équipés d'un contrôleur PERC S100 », à la page 47 • « Installation des pilotes de contrôleur au cours de l'installation du système d'exploitation : pour les systèmes équipés d'un contrôleur PERC S300 », à la page 49 Tableau 5-2. Conditions préalables à l'installation des pilotes de contrôleur (suite) Procédure Étapes 46 Installation des pilotes 6 Modifier la Liste de priorités des périphériques (le cas échéant) Pour modifier l'ordre des périphériques (CD-ROM, DVD optique etc), effectuez les actions suivantes : REMARQUE : sauf mention contraire, le terme utilitaire PERC Virtual Disk Management englobe l'utilitaire PERC S100 Virtual Disk Management et l'utilitaire PERC S300 Virtual Disk Management. REMARQUE : si l'utilitaire de gestion de disques virtuels PERC est ouvert, sélectionnez Continue to Boot (Poursuivre l'amorçage), puis appuyez sur . Appuyez sur pour réamorcer le système. a Démarrez le système. Lorsque l'écran POST apparaît, appuyez sur . b À l'écran Système Dell PowerEdge, utilisez les touches fléchées pour dérouler la séquence d'amorçage. Appuyez sur . c Assurez-vous que le disque dur C: est le premier de la liste. d Pour modifier la séquence des autres périphériques : •Utilisez la touche <+> pour déplacer les périphériques vers le haut,ou la touche <-> pour les déplacer vers le bas. •Appuyez sur la barre d'espacement pour activer ou désactiver un périphérique. e Appuyez sur <Échap> pour quitter. f Appuyez de nouveau sur <Échap>. Sélectionnez Enregistrer les modifications et quitter, puis appuyez sur Entrée. REMARQUE : passez à l'une des procédures suivantes : • « Installation des pilotes de contrôleur au cours de l'installation du système d'exploitation : pour les systèmes équipés d'un contrôleur PERC S100 », à la page 47 • « Installation des pilotes de contrôleur au cours de l'installation du système d'exploitation : pour les systèmes équipés d'un contrôleur PERC S300 », à la page 49 Tableau 5-2. Conditions préalables à l'installation des pilotes de contrôleur (suite) Procédure Étapes Installation des pilotes 47 Installation des pilotes de contrôleur au cours de l'installation du système d'exploitation : pour les systèmes équipés d'un contrôleur PERC S100 PRÉCAUTION : les derniers micrologiciels, pilotes et applications doivent être installés lorsque le logiciel du contrôleur est mis à niveau. Une version précédente du pilote peut ne pas fonctionner avec le dernier logiciel du contrôleur et vice versa. REMARQUE : lorsque vous utilisez un lecteur de disquette USB externe, veillez à le connecter au système lorsque celui-ci est hors tension et avant l'étape 1. Sinon, le lecteur de disquette USB externe risque de ne pas être reconnu par le système. 1 Redémarrez le système. Lorsque l'écran POST apparaît, appuyez sur . 2 Introduisez le support du système d'exploitation Windows dans le lecteur optique. 3 Lorsque le menu du gestionnaire de démarrage du BIOS ou de démarrage du périphérique s'affiche, sélectionnez le texte commençant par SATA intégré... et appuyez sur . 4 Installez le système d'exploitation applicable Microsoft Windows à l'aide des instructions qui s'affichent. 5 Lorsque la fenêtre Sélectionner le pilote à installer s'affiche, un sous-écran de Chargement du pilote apparaît. Procédez comme suit: Pour Microsoft Windows Server 2008 et Windows Server 2008 R2 : a Introduisez le CD-ROM, DVD, lecteur flash USB ou la disquette contenant les fichiers copiés à l'étape « Téléchargement du média de pilote de contrôleur », à la page 41. Cliquez sur Parcourir. b Dans la fenêtre Browse to folder (Rechercher le dossier), accédez au répertoire qui contient les fichiers des pilotes de contrôleur. Localisez ces fichiers et sélectionnez-les. Cliquez sur OK. Pour Microsoft Windows Server 2003 : a Introduisez la disquette contenant les fichiers copiés à l'étape « Téléchargement du média de pilote de contrôleur », à la page 41. (Utilisez un lecteur de disquette USB externe si votre système ne dispose pas d'un lecteur de disquette intégré).48 Installation des pilotes b Appuyez sur sur le clavier, lorsque vous y êtes invité au début de la configuration Windows. c Patientez jusqu'à ce que la fenêtre Windows Setup (Configuration Windows) avec S = Specify Additional Device (S = spécifier un périphérique supplémentaire) s'affiche. Appuyez sur sur le clavier. d Introduisez le support requis (le cas échéant), puis appuyez sur . 6 Dans la fenêtre Select the driver to be installed (Sélectionnez le pilote à installer) suivante, sélectionnez Contrôleur Dell PERC S100 S300r... Cliquez sur Suivant pour charger les fichiers des pilotes. Pour Microsoft Windows Server 2003 : Lorsque vous êtes invité à charger des pilotes supplémentaires, appuyez sur pour démarrer le processus d'installation de Microsoft Windows. 7 Dans la liste de la fenêtre Select the operating system you want to install (Sélectionnez le système d'exploitation à installer), sélectionnez le système d'exploitation applicable. Cliquez sur Suivant. 8 Suivez le reste des instructions d'installation du système d'exploitation. Certaines fenêtres ont besoin d'un mot de passe et d'informations système propres à l'utilisateur. Le cas échéant, contactez votre administrateur IT pour obtenir de l'aide. Pour Microsoft Windows Server 2003 uniquement : deux boîtes de dialogue d'avertissement apparaissent au cours de la partie Installation de Windows : • Lorsque la boîte de dialogue Software Installation (Installation du logiciel) apparaît, cliquez sur Oui. • Lorsque la boîte de dialogue Hardware Installation (Installation du matériel) apparaît, cliquez sur Oui. REMARQUE : lorsque le processus d'installation du système d'exploitation est terminé, retirez le média d'installation introduit à l'étape étape 5.Installation des pilotes 49 Installation des pilotes de contrôleur au cours de l'installation du système d'exploitation : pour les systèmes équipés d'un contrôleur PERC S300 PRÉCAUTION : les derniers micrologiciels, pilotes et applications doivent être installés lorsque le logiciel du contrôleur est mis à niveau. Une version précédente du pilote peut ne pas fonctionner avec le dernier logiciel du contrôleur et vice versa. REMARQUE : lorsque vous utilisez un lecteur de disquette USB externe, veillez à le connecter au système lorsque celui-ci est hors tension et avant l'étape 1. 1 Redémarrez le système. Lorsque l'écran POST apparaît, appuyez sur . 2 Introduisez le support du système d'exploitation Windows dans le lecteur optique. 3 Lorsque la fenêtre du Gestionnaire de démarrage du BIOS apparaît, sélectionnez le texte qui commence par Lecteur optique SATA... puis appuyez sur . 4 Installez le système d'exploitation applicable Microsoft Windows à l'aide des instructions qui s'affichent. 5 Dans la liste de la fenêtre Select the operating system you want to install (Sélectionnez le système d'exploitation à installer), sélectionnez le système d'exploitation applicable. Cliquez sur Suivant. 6 Suivez le reste des instructions qui s'affichent dans les fenêtres suivantes. 7 À Install Windows-Where do you want to install Windows? (Installer Windows-Où souhaitez-vous installer Windows ?), procédez comme suit : Pour Microsoft Windows Server 2008 et Windows Server 2008 R2 : a Introduisez le CD-ROM, DVD, lecteur flash USB ou la disquette contenant les fichiers copiés à l'étape « Téléchargement du média de pilote de contrôleur », à la page 41. Cliquez sur Charger le pilote. b Dans le sous-écran Charger le pilote, cliquez sur Parcourir. c Sélectionnez le répertoire qui contient les fichiers des pilotes du contrôleur. Cliquez sur OK.50 Installation des pilotes Pour Microsoft Windows Server 2003 : a Introduisez la disquette contenant les fichiers copiés à l'étape « Téléchargement du média de pilote de contrôleur », à la page 41. (Utilisez un lecteur de disquette USB externe si votre système ne dispose pas d'un lecteur de disquette intégré). b Appuyez sur sur le clavier, lorsque vous y êtes invité au début de la configuration Windows. c Patientez jusqu'à ce que la fenêtre Windows Setup (Configuration Windows) avec S = Specify Additional Device (S = spécifier un périphérique supplémentaire) s'affiche. Appuyez sur sur le clavier. d Introduisez le média requis (le cas échéant), puis appuyez sur . 8 Dans la fenêtre Select the driver to be installed (Sélectionner le pilote à installer), sélectionnez Contrôleur Dell PERC S100, S300... Cliquez sur Suivant pour charger les fichiers des pilotes. Pour Microsoft Windows Server 2003 : lorsque vous êtes invité à charger des pilotes supplémentaires, appuyez sur pour démarrer le processus d'installation de Microsoft Windows. 9 Suivez le reste des instructions d'installation du système d'exploitation. Certaines fenêtres ont besoin d'un mot de passe et d'informations système propres à l'utilisateur. Le cas échéant, contactez votre administrateur IT pour obtenir de l'aide. Pour Microsoft Windows Server 2003 uniquement : deux boîtes de dialogue d'avertissement apparaissent au cours de la partie Installation de Windows : – Lorsque la boîte de dialogue Software Installation (Installation du logiciel) apparaît, cliquez sur Oui. – Lorsque la boîte de dialogue Hardware Installation (Installation du matériel) apparaît, cliquez sur Oui. REMARQUE : lorsque le processus d'installation du système d'exploitation est terminé, retirez le média d'installation introduit à l’étape 7.Installation des pilotes 51 Réalisation des procédures de configuration de gestion pour le contrôleur PERC S100 ou le contrôleur PERC S300 Les procédures de configuration de gestion pour le contrôleur PERC S100 ou le contrôleur PERC S300 sont décrites dans Dell OpenManage Server Administrator Storage Management. Pour configurer un contrôleur PERC S100 ou un contrôleur PERC S300 sur votre système, reportez-vous aux procédures Storage Management situées sur le site Web de support Dell à l'adresse support.dell.com/manuals.52 Installation des pilotesConfiguration et gestion de RAID 53 Configuration et gestion de RAID Le contrôleur Dell PowerEdge RAID (PERC) S100 et le contrôleur PERC S100 sont configurés à l'aide de l'utilitaire PERC S100 Virtual Disk Management ou Virtual Disk Management PERC S300. Cet utilitaire est accessible au démarrage du système, lorsque vous êtes invité à appuyer sur . REMARQUE : sauf indication contraire, le terme utilitaire de gestion de disques virtuels PERC englobe l'utilitaire PERC S100 Virtual Disk Management utility et l'utilitaire PERC S300 Virtual Disk Management. REMARQUE : pour configurer le contrôleur PERC S100 ou le contrôleur PERC S300 avec Dell OpenManage Server Administrator Storage Management, reportez-vous au site Web de support Dell à l'adresse support.dell.com/manuals. REMARQUE : l'utilitaire de gestion de disques virtuels PERC est accessible et peut être configuré sans que les pilotes du système d'exploitation et du contrôleur soient installés. Configuration du contrôleur : utilisation de l'utilitaire de gestion de disques virtuels PERC Tableau 6-1. Opérations de l'utilitaire de gestion de disques virtuels PERC Opération Description Accès à l'utilitaire de gestion de disques virtuels PERC Explique comment se connecter à l'utilitaire gestion de disques virtuels PERC. Comprendre les couleurs de texte dans l'utilitaire gestion de disques virtuels PERC Décrit l'état des disques physiques et des disques virtuels, d'après le texte surligné en couleur. Initialisation des disques physiques Décrit comment initialiser un disque physique pour le stockage de données. Création de disques virtuels Décrit comment créer un disque virtuel à partir des disques physiques connectés.54 Configuration et gestion de RAID Accès à l'utilitaire de gestion de disques virtuels PERC 1 Démarrez le système et patientez jusqu'à l'apparition du message Press Configure (Appuyer pour configurer). 2 Appuyez sur . Vous disposez d'un maximum de trois secondes pour appuyer sur , ou le processus de démarrage du système se poursuivra. PRÉCAUTION : si le contrôleur SATA n'est pas défini sur un mode RAID, des données peuvent être détruites. Veillez à sauvegarder toutes les données avant de changer de mode. Suppression de disques virtuels Efface un ou plusieurs disques virtuels configurés pour le contrôleur. Permutation de deux disques virtuels Permute des disques virtuels pour leur permettre de se charger dans n'importe quel ordre. Gestion des disques de rechange globaux Permet de créer ou d'effacer un disque de rechange global. Affichage des détails concernant les disques physiques Permet d'afficher des informations détaillées sur n'importe quel disque physique connecté. Affichage des détails concernant les disques virtuels Permet d'afficher des informations détaillées sur n'importe quel disque virtuel. Rebalayage des disques Effectue un nouveau balayage des disques pour détecter les nouveaux disques physiques ou virtuels ou ceux qui ont été retirés. Options du contrôleur Modifie les options du contrôleur sélectionné, telles que l'amorçage et les avertissements de disque virtuel. Poursuite du démarrage Permet au système de poursuivre l'amorçage après utilisation de l'utilitaire gestion de disques virtuels PERC utility. Tableau 6-1. Opérations de l'utilitaire de gestion de disques virtuels PERC (suite) Opération DescriptionConfiguration et gestion de RAID 55 REMARQUE : si l'utilitaire de gestion de disques virtuels PERC ne s'affiche pas et que votre système utilise un PERC S100, appuyez sur F2 pour accéder au BIOS du système Dell. Dans le champ Paramètres SATA, mettez le contrôleur SATA en Mode RAID. Si les paramètres sont corrects et que l'utilitaire gestion de disques virtuels PERC ne s'affiche toujours pas, contactez le support Dell à l'adresse support.dell.com. L'utilitaire comprend les champs suivants : • Un champ d'informations (texte jaune ou rouge) : situé sous le nom de la fenêtre et le numéro de version actuelle. • Disques virtuels : affiche les disques virtuels qui ont été créés et les informations les concernant : numéro du disque virtuel, niveau de RAID, taille du disque virtuel, état du disque virtuel et état du mode de mise en cache. • Menu principal : répertorie les opérations principales de l'utilitaire de gestion de disques virtuels PERC. • Disques physiques : affiche des informations sur les disques physiques ou périphériques ATAPI. • Touches disponibles : indique les touches du clavier à utiliser pour sélectionner une ligne de texte ou effectuer une opération. REMARQUE : pour obtenir la description de l'état des disques virtuels et des disques physiques, reportez-vous au TableauB-2 et au TableauB-3, disponibles sur le site Web de support Dell à l'adresse support.dell.com/manuals. REMARQUE : le premier disque virtuel de la liste Disques virtuels doit être un disque virtuel amorçable. Le système peut uniquement démarrer lorsque le disque virtuel amorçable est en première position dans la liste. Comprendre les couleurs de texte dans l'utilitaire gestion de disques virtuels PERC La couleur du texte de l'utilitaire gestion de disques virtuels PERC utility correspond à des codes, comme suit : Tableau 6-2. gestion de disques virtuels PERC Couleurs du texte Couleur de texte Description Texte blanc Option disponible ou texte informatif. Texte noir, surligné jaune Option ou périphérique pour lesquels une action peut être effectuée.56 Configuration et gestion de RAID Initialisation des disques physiques Les nouveaux disques physiques doivent être initialisés avant leur utilisation. L'initialisation écrit les informations de configuration du contrôleur sur le disque physique. Les disques physiques dans l'état suivant peuvent être initialisés : • Non RAID : disque physique configuré par un non-contrôleur PERC S100 ou contrôleur PERC S300. • Prêt : ne contient pas de données stockées mais des informations de configuration contrôleur PERC S100 ou Informations de configuration contrôleur PERC S300. Les disques physiques En ligne ne peuvent pas être initialisés. 1 Mettez le système sous tension pour commencer l'amorçage. 2 Lorsque vous y êtes invité, appuyez sur les touches pour accéder à l'utilitaire gestion de disques virtuels PERC. 3 Dans le champ Menu principal, utilisez les touches fléchées pour sélectionner l'option Initialize Physical Disk(s)(Initialiser les disques physiques). 4 Appuyez sur . 5 À l'aide des touches fléchées, sélectionnez Initialize for PERC S100 (PERC S300) (Initialiser pour PERC S100 [PERC S300]) ou Initialize to Non-Raid (Initialiser pour Non-Raid). 6 Appuyez sur . Texte jaune Informations de l'option surlignée en jaune. Texte vert Article sélectionné. Texte bleu clair L'article ne peut pas être sélectionné. Texte magenta Articles liés à des disques de rechange ou à des options de démarrage. Texte rouge Disque physique ou virtuel en échec ou avertissement. Par exemple, un texte informatif peut être rouge si une option n'est pas disponible. Tableau 6-2. gestion de disques virtuels PERC Couleurs du texte Couleur de texte DescriptionConfiguration et gestion de RAID 57 7 À l'aide des touches fléchées, sélectionnez un disque physique. Appuyez sur pour sélectionner le disque physique, ou sur la touche pour choisir tous les disques physiques sélectionnables. REMARQUE : vous pouvez sélectionner et initialiser plusieurs disques physiques. Il n'y a pas besoin d'initialiser un seul disque physique à la fois. 8 Appuyez sur pour initialiser le ou les disques physiques sélectionnés. REMARQUE : après avoir initialisé un disque physique en tant que Non RAID, il apparaît comme Non RAID dans le champ Disques physiques de l'utilitaire PERC Virtual Disk Management. Un disque virtuel Non RAID est également créé et apparaît dans le champ Disques virtuels. 9 Une boîte de dialogue apparaît et signale que toutes les données du disque physique seront irrémédiablement perdues s'il est initialisé. Appuyez sur la touche pour continuer l'initialisation ou sur <Échap> pour l'annuler. L'initialisation prend de 10 à 15 secondes par disque physique. Un voyant d'état signale le disque physique en cours d'initialisation. Lorsque l'initialisation est terminée, le voyant d'état s'éteint et tous les canaux sont automatiquement rebalayés. PRÉCAUTION : si un disque physique possède un disque virtuel, le disque physique ne peut pas être sélectionné pour initialisation. Pour l'initialiser, effacez le disque virtuel. Assurez-vous que l'initialisation de ce disque physique est vraiment souhaitable, car toutes ses données (notamment les informations de configuration contrôleur PERC S100 ou contrôleur PERC S300) seront supprimées. REMARQUE : lorsque des disques physiques Non RAID sont installés sur le système, les disques virtuels Non RAID qui leur sont associés doivent être supprimés pour pouvoir utiliser les disques physiques avec le contrôleur PERC S100ou le contrôleur PERC S300. La suppression des disques virtuels NonRaid initialise les disques physiques Non-Raid et fait passer leur état à Prêt. REMARQUE : passez ensuite à la procédure suivante, « Création de disques virtuels ».58 Configuration et gestion de RAID Création de disques virtuels Vous pouvez créer des disques virtuels une fois les disques physiques initialisés, particulièrement si le disque virtuel est le disque virtuel amorçable de votre système. Si vous n'avez pas décidé quel niveau de RAID utiliser, reportez-vous au Guide RAID, disponible sur le site Web de support Dell à l'adresse support.dell.com/manuals. Avant de commencer • Au cours de cette procédure, vous pouvez revenir à l'état précédent à n'importe quel moment en appuyant sur <Échap>. • Un maximum de huit disques virtuels peuvent être créés avec l'utilitaire gestion de disques virtuels PERC. • Évitez de combiner des niveaux de raid redondants et non redondants sur le même ensemble de disques physiques. REMARQUE : l'opération Create Virtual Disk (Créer des disques virtuels) n'est pas sélectionnable lorsque les disques physiques ne disposent pas de capacité suffisante. 1 Mettez le système sous tension pour commencer l'amorçage. 2 Lorsque vous y êtes invité, appuyez sur les touches pour accéder à l'utilitaire de gestion de disques virtuels PERC. 3 Dans le champ Menu principal, utilisez les touches fléchées pour sélectionner Create Virtual Disk (Créer un disque virtuel). Appuyez sur . 4 Dans le champ Disques physiques, sélectionnez les disques physiques sur lesquels créer les disques virtuels : a Pour sélectionner chaque disque physique, appuyez sur la touche . (Les disques physiques peuvent être insérés dans n'importe quel ordre). b Une fois les disques physiques à inclure sur le disque virtuel sélectionnés, appuyez sur . 5 Dans le champ User Input (Entrée utilisateur), utilisez les touches fléchées pour sélectionner un type de disque virtuel (niveau de RAID). Appuyez sur . (Seuls les types de disques virtuels qui peuvent être créés avec les disques physiques sélectionnés sont indiqués ; ils sont surlignés en texte blanc).Configuration et gestion de RAID 59 6 Si des disques de rechange (de secours) sont applicables : a Dans le champ User Input (Entrée utilisateur), utilisez les touches fléchées pour sélectionner un disque physique dédié. Appuyez sur . REMARQUE : un disque de rechange peut être affecté après la création d'un disque virtuel, en sélectionnant l'option Manage Global Hot Spare(s) (Gérer les disques de rechange globaux). b Dans le champ Disques physiques, sélectionnez le disque physique à utiliser en tant que disque de rechange (le cas échéant). Appuyez sur pour le sélectionner. c Appuyez sur pour ajouter le disque de rechange. Appuyez sur la touche pour confirmer la modification. 7 Sélectionnez une taille de disque virtuel, en fonction de l'espace disponible des disques physiques. Relisez les choix faits dans le Tableau 6-3. (Les modifications de la taille du disque virtuel sont affichées dans les champs Create Virtual Disk (Créer un disque virtuel) et User Input (Entrée utilisateur.) REMARQUE : la taille maximale du disque virtuel est affectée par l'espace disponible des disques physiques et par le niveau de RAID choisi. 8 Une fois la taille du disque virtuel choisie, appuyez sur . 9 Dans le champ User Input (Entrée utilisateur), sélectionnez un Mode de mise en cache. Appuyez sur . 10 Appuyez sur la touche pour confirmer que vous voulez créer le disque virtuel. 11 Dans le champ Menu principal, effectuez d'autres opérations ou sélectionnez Continue to Boot (Continuer l'amorçage) et appuyez sur . REMARQUE : le disque virtuel d'amorçage doit se trouver en tête de la liste du champ Disques virtuels. Si nécessaire, utilisez l'option Swap Two Virtual Disks (Permuter deux disques virtuels) pour placer le disque virtuel amorçable en première position.60 Configuration et gestion de RAID REMARQUE : si vous souhaitez avoir un disque virtuel amorçable, veillez à ce que la prise en charge INT 13 soit activée sur le contrôleur, comme décrit à la section « Options du contrôleur », à la page 65. Suppression de disques virtuels PRÉCAUTION : bien que n'importe quel disque virtuel du champ Disques virtuels puisse être supprimé, notamment le premier disque virtuel de la liste, ne le supprimez pas. Il se peut qu'il serve à amorcer le système. La suppression du disque virtuel amorçable efface les pilotes du système d'exploitation et du contrôleur. Tableau 6-3. Sélection de la taille des disques virtuels) Pour créer des disques virtuel de taille suivante : Effectuer cette tâche < 2,199 To Utilisez les touches ou pour passer d'une dimension à une autre par grands incréments. ou Utilisez les touches fléchées haut et bas pour passer d'une dimension à une autre par petits incréments. Passez à l'étape « Création de disques virtuels », à la page 58. < 2,199 To 1 Appuyez sur la touche ou la touche fléchée haut pour augmenter la taille du disque virtuel. 2 Une boîte de dialogue apparaît dans le champ User Input (Entrée utilisateur) lorsque la taille maximale est atteinte. Elle demande si vous souhaitez limiter la taille du disque virtuel ou dépasser la taille maximale normale. 3 Appuyez sur <Échap> pour créer un disque virtuel de plus grande taille. 4 Appuyez sur les touches ou la flèche haut jusqu'à ce que vous atteigniez la taille désirée ou la taille maximale. 5 Passez à l'étape « Création de disques virtuels », à la page 58. REMARQUE: lorsque des disques physiques de capacités différentes sont utilisés, la taille maximale du disque virtuel est limitée par la taille du disque physique de plus petite capacité. Configuration et gestion de RAID 61 PRÉCAUTION : lorsqu'un disque physique est supprimé d'un système, les informations de configuration actuelles du contrôleur PERC S100 ou PERC S300 (métadonnées) demeurent sur le disque. Si le disque physique supprimé entraîne l'échec du disque virtuel, et que le disque virtuel est ensuite effacé et qu'un rebalayage est effectué, la réinsertion du disque physique entraîne la fusion par l'utilitaire PERC Virtual Disk Management des informations de configuration du disque physique réinséré et des informations de configuration existantes. Le disque virtuel précédemment supprimé réapparaît dans l'utilitaire PERC Virtual Disk Management. PRÉCAUTION : assurez-vous que tous les disques physiques faisant partie d'un disque virtuel sont dans le système avant de supprimer le disque virtuel. 1 Mettez le système sous tension pour commencer l'amorçage. 2 Lorsque vous y êtes invité, appuyez sur les touches pour accéder à l'utilitaire gestion de disques virtuels PERC. 3 Dans le champ Menu principal, sélectionnez Delete Virtual Disk(s) (Supprimer des disques virtuels). Appuyez sur . 4 Effectuez l'une des procédures suivantes: • Sélectionnez chaque disque virtuel du champ Disques virtuels que vous souhaitez supprimer. Appuyez sur pour confirmer chaque sélection. OU • Appuyez sur pour sélectionner tous les disques virtuels pour une suppression. REMARQUE : la couleur du texte des disques virtuels sélectionnés passe au vert. 5 Appuyez sur . PRÉCAUTION : la boîte de dialogue qui apparaît décrit les conséquences de la suppression des disques virtuels sélectionnés. La suppression du disque virtuel détruit non seulement ses données de manière permanente, mais le disque virtuel lui-même. Cette action est irréversible. 6 Appuyez sur la touche pour confirmer la suppression.62 Configuration et gestion de RAID Permutation de deux disques virtuels L'option Swap Two Virtual Disks de l'utilitaire gestion de disques virtuels PERC permet de réarranger les disques virtuels dans un ordre différent. PRÉCAUTION : ne permutez pas le premier disque virtuel de la liste Disques virtuels s'il s'agit du disque virtuel d'amorçage du système. Le disque virtuel amorçable doit toujours se situer en tête de la liste des Disques virtuels. Avant de commencer • L'option Swap Two Virtual Disks (Permuter deux disques virtuels) est uniquement activée s'il existe au moins un disque physique initialisé dans le système. Par exemple, si tous les disques physiques du système sont Non Raid, l'option Swap Two Virtual Disks est désactivée. • Il est recommandé que le disque virtuel amorçable soit de type redondant, tel que RAID 1, RAID 5 ou RAID 10, pour conserver les données en cas de défaillance d'un disque physique dans le disque virtuel. Le cas échéant, permutez ce disque virtuel en première position de la liste Disques virtuels, s'il ne se trouve pas en tête. Reportez-vous à l'option Swap Two Virtual Disks ci-dessous. • Le périphérique et l'ordre d'amorçage sont sélectionnables par l'utilisateur. • La fonction de permutation est disponible uniquement sur l'utilitairegestion de disques virtuels PERC. REMARQUE : seuls deux disques virtuels peuvent être permutés simultanément. 1 Mettez le système sous tension pour commencer l'amorçage. 2 Lorsque vous y êtes invité, appuyez sur les touches pour accéder à l'utilitaire de gestion de disques virtuels PERC. 3 Dans le champ Menu principal, sélectionnez Swap Two Virtual Disks. Appuyez sur . 4 À l'aide des touches fléchées, sélectionnez un disque virtuel dans le champ Disque virtuel. Appuyez sur . 5 À l'aide des touches fléchées, sélectionnez un autre disque virtuel. Appuyez sur . 6 Appuyez sur pour permuter les disques virtuels.Configuration et gestion de RAID 63 Gestion des disques de rechange globaux Cette option permet de créer un disque de rechange global à partir d'un disque physique sélectionné, ou de supprimer un disque de rechange global. REMARQUE : un disque de rechange global peut être créé uniquement si un disque physique se trouve en état Prêt ou Normal dans le champ Disques physiques. Si le disque physique est en état En ligne, il est en cours d'utilisation par un disque virtuel et ne peut pas être sélectionné en tant que disque de rechange. Créer un disque de rechange global 1 Mettez le système sous tension pour commencer l'amorçage. 2 Lorsque vous y êtes invité, appuyez sur les touches pour accéder à l'utilitaire de gestion de disques virtuels PERC. 3 Dans le champ Menu principal, sélectionnez Manage Global Spare(s) (Gestion des disques de rechange globaux). Appuyez sur . 4 Sélectionnez Assign Global Hot Spare(s) (Affecter des disques de rechange globaux). Appuyez sur . 5 À l'aide des flèches haut et bas, sélectionnez les disques physiques à utiliser en tant que disques de rechange globaux. Appuyez sur . 6 Appuyez sur pour ajouter le disque de rechange global. 7 Appuyez sur la touche pour confirmer l'action. Supprimer un disque de rechange global 1 Mettez le système sous tension pour commencer l'amorçage. 2 Lorsque vous y êtes invité, appuyez sur les touches pour accéder à l'utilitaire gestion de disques virtuels PERC. 3 Dans le champ Menu principal, sélectionnez Manage Global Spare(s) (Gestion des disques de rechange globaux). Appuyez sur . 4 Sélectionnez Unassign Global Hot Spare(s) (Désaffecter des disques de rechange globaux). Appuyez sur . 5 À l'aide des flèches haut et bas, sélectionnez les disques physiques à supprimer en tant que disques de rechange globaux. Appuyez sur . 6 Appuyez sur pour supprimer le disque de rechange global. 7 Appuyez sur la touche pour confirmer l'action.64 Configuration et gestion de RAID Affichage des détails concernant les disques physiques 1 Mettez le système sous tension pour commencer l'amorçage. 2 Lorsque vous y êtes invité, appuyez sur les touches pour accéder à l'utilitaire gestion de disques virtuels PERC. 3 Dans le champ Menu principal, sélectionnez View Physical Disk Details (Afficher les détails du disque physique). Appuyez sur . 4 À l'aide des touches fléchées, sélectionnez un disque physique. 5 Les informations du disque physique s'affichent en haut de la fenêtre : • Numéro du disque physique • Numéro de canal • Taille du disque physique • État du disque physique : New (Nouveau)/Non-Raid/Ready (Prêt)/Online (En ligne) • Espace disponible • Fabricant et numéro de modèle 6 Lorsque vous avez terminé, appuyez sur <Échap> pour revenir à la fenêtre principale. Affichage des détails concernant les disques virtuels 1 Mettez le système sous tension pour commencer l'amorçage. 2 Lorsque vous y êtes invité, appuyez sur les touches pour accéder à l'utilitaire gestion de disques virtuels PERC. 3 Dans le champ Menu principal, sélectionnez View Virtual Disk Details (Afficher les détails du disque virtuel). Appuyez sur . 4 À l'aide des touches fléchées, sélectionnez un disque virtuel. 5 Les informations du disque virtuel s'affichent en haut de la fenêtre dans le champ Disques virtuels : • Numéro du disque virtuel • niveau de RAID • Taille • État (L/É, R, NA)Configuration et gestion de RAID 65 6 Lorsque vous avez terminé, appuyez sur <Échap> pour revenir à la fenêtre principale. REMARQUE : le champ Disquesphysiques répertorie les disques physiques du disque virtuel, surlignés en vert. Rebalayage des disques Cette option permet de balayer de nouveau tous les canaux et de détecter les disques physiques ou virtuels nouveaux ou supprimés. • Pour effectuer un nouveau balayage, sélectionnez Rescan Disks (Rebalayer les disques) dans le Menu principal et appuyez sur . (Le voyant d'activité, visible dans le champ d'informations situé en haut de la fenêtre, tourne lorsque les disques physiques sont en cours d'analyse.) • L'option Rescan Disks (Rebalayer les disques) analyse de nouveau tous les canaux, recherche les disques physiques nouveaux ou supprimés, et relit les informations de configuration de chaque disque physique. REMARQUE : lorsqu'un disque physique tombe en panne, il arrive que le rebalayage le fasse apparaître en ligne. Options du contrôleur La fonction Controller Options (Options du contrôleur) permet de sélectionner la prise en charge d'amorçage INT 13 et de décider d'interrompre le processus d'amorçage lorsqu'une erreur survient. Le processus d'amorçage s'interrompt lorsque Pause if... (Interrompre si...) est activé et si un disque virtuel se retrouve dans l'état Dégradé ou Failed (En échec/défaillant). Appuyez sur pour continuer l'amorçage. Afficher le message d'erreur dans la fenêtre. Si Pause... est Désactivé, le message d'erreur est affiché brièvement, mais le système continue l'amorçage. 1 Dans le champ Menu principal, utilisez la touche fléchée pour sélectionner Options du contrôleur. Appuyez sur . 2 Dans le champ Options du contrôleur, recherchez l'option de contrôleur souhaitée à l'aide des touches fléchées haut ou bas. Voir le Tableau 6-4. 3 Lorsque vous avez terminé, appuyez sur <Échap> pour revenir à la fenêtre principale.66 Configuration et gestion de RAID Poursuite du démarrage Après utilisation de l'utilitaire de gestion de disques virtuels PERC, poursuivez le processus d'amorçage normal du système en sélectionnant Continue to Boot (Continuer l'amorçage) dans le champ Menu principal et en appuyant sur . Tableau 6-4. Options du contrôleur Option du contrôleur Description Fonctionnement INT13 Boot Support (Prise en charge de l'amorçage INT13) Détermine si le BIOS installe la prise en charge INT 13 (opérations de recherche, de lecture et d'écriture d'un disque physique pour un contrôleur PERC S100 ou un contrôleur PERC S300). Appuyez sur pour basculer entre ON (Activé) et OFF (Éteint). Pause if Degraded (Interrompre si dégradé) Lorsque cette option est activée, le BIOS arrête le démarrage lorsqu'un disque virtuel dégradé est détecté. Appuyez sur pour basculer entre ON (Activé) et OFF (Éteint). Pause if Failed (Interrompre si défaillant) Lorsque cette option est activée, le BIOS arrête le démarrage lorsqu'un disque virtuel défaillant est détecté. Appuyez sur pour basculer entre ON (Activé) et OFF (Éteint).Dépannage 67 Dépannage Pour obtenir de l'aide pour votre contrôleur PERC S100 et votre contrôleur PERC S300 Dell PowerEdge RAID Controller (PERC), contactez votre technicien Dell ou accédez au site Web de support Dell à l'adresse support.dell.com. Ce chapitre présente les quatre catégories principales de dépannage : • Les tâches normales qui ne peuvent être exécutées au cours du démarrage du système. • Les messages d'avertissement qui peuvent apparaître à l'écran Dell PERC S100 Controller (BIOS) ou Dell PERC S300 Controller (BIOS). • Les fonctions qui ne peuvent pas être réalisées avec des disques virtuels. • Les fonctions qui ne peuvent pas être réalisées avec des disques physiques. REMARQUE : sauf mention contraire, le terme utilitaire PERC Virtual Disk Management englobe l'utilitaire PERC S100 Virtual Disk Management et l'utilitaire PERC S300 Virtual Disk Management.68 Dépannage Problèmes de démarrage du système Le tableau ci-dessous indique des causes éventuelles liées à l'adaptateur contrôleur PERC S100 ou au PERC S300 entraînant des problèmes de démarrage du système. Tableau 7-1. Le système ne redémarre pas Causes à considérer Mesures correctives Le mode du contrôleur est défini incorrectement dans la configuration du système 1 Au démarrage du système, lorsque l'écran Dell Power-On Self-Test Controller (POST) apparaît, appuyez sur pour aller à l'écran Dell Inc. PowerEdge BIOS. 2 Descendez aux Paramètres SATA. Appuyez sur et vérifiez les points suivants : • Pour un contrôleur PERC S100 : le contrôleur SATA est défini sur un mode RAID. • Pour un contrôleur PERC S300 : le contrôleur SATA est défini sur un mode ATA ou AHCI. REMARQUE : une perte de données peut se produire lors du basculement du mode RAID vers le modeATA.Dépannage 69 Le mode d'amorçage, la séquence d'amorçage et/ou la Nouvelle tentative de séquence d'amorçage ne sont pas correctement définis 1 Au démarrage du système, lorsque l'écran Dell Inc. PowerEdge BIOS Dell apparaît, appuyez sur pour aller à l'écran. 2 Descendez aux Paramètres d'amorçage. Appuyez sur et assurez-vous que le mode d'amorçage est défini sur BIOS. 3 Descendez à la Séquence d'amorçage. Appuyez sur et assurez-vous que le disque dur C: (* contrôleur PERC S100 ou adaptateur PERC S300) est le premier périphérique de la liste. * Le texte variable affiché ici peut être : SATA 1 intégré, Emplacement 1 ou SAS intégré. 4 Descendez à Boot Sequence Retry (Nouvelle tentative de séquence d'amorçage). Vérifiez que le paramètre est Activé. 5 Appuyez sur <Échap> pour quitter et continuer l'amorçage. REMARQUE : si des modifications sont effectuées à l'écran Dell Inc. PowerEdge BIOS, la boîte de dialogue qui apparaît vous invite à enregistrer vos modifications puis à quitter. Le disque virtuel amorçable est en échec 1 Appuyez sur pour redémarrer. 2 Une fois le système redémarré, appuyez sur . Vérifiez l'état du disque virtuel amorçable dans le champ Disque virtuel, ou en sélectionnant Afficher les détails du disque virtuel et en appuyant sur . 3 Recherchez les disques physiques manquants ou hors ligne. Tableau 7-1. Le système ne redémarre pas Causes à considérer Mesures correctives70 Dépannage L'ordre de démarrage n'est pas correct pour un disque virtuel amorçable 1 Lorsque vous y êtes invité au démarrage du système, appuyez sur pour accéder au Gestion de disques virtuels PERC . 2 Vérifiez les Disques virtuels et assurez-vous que le disque virtuel amorçable est le premier de la liste. 3 Le cas échéant, utilisez l'option Swap Two Virtual Disks (Permuter deux disques virtuels) pour replacer les disques virtuels. Un disque virtuel Non-Raid ne se trouve plus en première position dans la liste de l'utilitaire gestion de disques virtuels PERC après le redémarrage du système REMARQUE : lorsque le système s'amorce à partir d'un disque virtuel Non-Raid, la création d'un disque virtuel dans Dell OpenManage Server Administrator Storage Management modifie l'ordre des disques virtuels et place le disque virtuel Non-Raid amorçable en première position.Le contrôleur PERC S100 ou le contrôleur PERC S300 tente ensuite d'amorcer à partir du premier disque virtuel. REMARQUE : Un disque virtuel non Raid peut être créé à partir de disques physiques non Raid (qui sont des disques physiques initialisés sur un contrôleur autre que le contrôleur PERC S100 ou le contrôleur PERC S300). 1 Lorsque vous y êtes invité au démarrage du système, appuyez sur pour accéder à l'utilitaire gestion de disques virtuels PERC. 2 Allez sur les Disques virtuels et vérifiez si le disque virtuel Non-Raid amorçable n'est plus en première position. 3 À l'aide de l'option Swap Two Virtual Disks (Permuter deux disques virtuels), déplacez les disques virtuels et placez le disque virtuel non RAID amorçable en première position dans le champ Disques virtuels. Tableau 7-1. Le système ne redémarre pas Causes à considérer Mesures correctivesDépannage 71 Messages d'avertissement : contrôleur Dell Inc. PERC S100 ou Dell Inc. PERC S300 Écran du BIOS L'écran Dell PERC S100 Controller (BIOS) ou Dell PERC S300 Controller (BIOS) est l'un des premiers écrans à apparaître au cours de la séquence d'amorçage de votre système. Si les disques virtuels de votre système étaient dans un état Normal ou Prêt avant le démarrage du système, la séquence d'amorçage se déroule normalement sur le système d'exploitation du serveur Microsoft Windows Server 2008 ou MicrosoftWindowsServer 2003. En revanche, si un disque virtuel se trouve dans un état Dégradé ou En échec, ou si certaines options du champ Options du contrôleur ont été modifiées au préalable dans l'utilitaire gestion de disques virtuels PERC, les messages d'avertissement décrits du Tableau 7-3 au Tableau 7-6 s'affichent au cours de la séquence d'amorçage. Pour les autres problèmes, reportez-vous au Tableau 7-7. Tableau 7-2. L'option Gestion des disques virtuels PERC ne s'affiche pas Causes à considérer Mesures correctives Le mode contrôleur PERC S100 n'est pas correctement défini dans le BIOS du système Reportez-vous au Tableau 7-1 pour connaître le paramètre SATA correct. Le contrôleur PERC S300 n'est pas installé correctement Vérifiez que le contrôleur PERC S300 se trouve dans le bon logement et qu'il est correctement emboîté.72 Dépannage Tableau 7-3. Messages d'avertissement : BIOS du contrôleur Dell Inc. PERC S100 ou PERC S300 Message d'avertissement Mesure corrective WARNING : Found virtual disks that are Degraded (AVERTISSEMENT : disques virtuels dégradés détectés) Ce message d'avertissement s'affiche lorsqu'au moins un disque virtuel est dans l'état Dégradé et que Pause if Degraded (Suspendre si dégradé) est défini sur ON (Activé) dans l'utilitaire gestion de disques virtuels PERC. Le message suivant apparaît après l'avertissement : --- Press to continue, or to enter setup --- (Appuyez sur Entrée pour continuer, ou sur Ctrl R pour entrer dans la configuration) Appuyez sur pour permettre au système d'exploitation de poursuivre la séquence d'amorçage, ou sur pour entrer dans l'utilitaire gestion de disques virtuels PERC et identifier la cause de la dégradation du disque virtuel. Pour en rechercher la cause, vérifiez les points suivants : • Un disque physique du disque virtuel est-il défaillant ou hors ligne. Vérifiez l'état dans le champ Disques physiques. Un état Dégradé dépend du niveau de RAID du disque virtuel et du nombre de disques physiques défaillants : – Pour un disque virtuel en RAID 1 ou RAID 5, il suffit d'un seul disque physique défaillant pour provoquer l'état Dégradé. – Pour un disque virtuel en RAID 10, c'est l'échec d'un disque physique dans chaque ensemble de miroir qui crée l'état Dégradé. L'échec de deux disques physiques dans le même ensemble de miroir crée un état En échec dans RAID 10. • Le contrôleur est-il défaillant en raison d'un échec du micrologiciel ou d'un composant. Un contrôleur défaillant empêche l'amorçage du disque virtuel. Pour modifier l'état Dégradé du disque virtuel, le disque physique défaillant doit être remplacé et le disque virtuel reconstruit à l'aide de Dell OpenManage Server Administrator Storage Management. Lorsque l'opération de reconstruction est terminée, l'état du disque virtuel passe de Dégradé à Prêt. Pour obtenir une description de la fonction de reconstruction, reportez-vous au Storage Management, situé sur le site de support Dell à l'adresse support.dell.com/manuals.Dépannage 73 Tableau 7-4. Messages d'avertissement : BIOS du contrôleur Dell Inc. PERC S100 ou PERC S300 (suite) Message d'avertissement Mesure corrective WARNING: Found virtual disks that are Failed (AVERTISSEMENT : disques virtuels défaillants détectés) Ce message d'avertissement s'affiche lorsqu'au moins un disque virtuel est dans l'état Défaillant et que Pause if Failed (Suspendre si défaillant) est défini sur ON (Activé) dans l'utilitaire de gestion de disques virtuels PERC. Le message suivant apparaît après l'avertissement : --- Press to continue, or to enter setup --- (Appuyez sur Entrée pour continuer, ou sur Ctrl R pour entrer dans la configuration) Appuyez sur pour permettre au système d'exploitation de continuer son démarrage, ou sur pour entrer dans l'utilitaire gestion de disques virtuels PERC et rechercher la cause de la défaillance du disque virtuel. REMARQUE : un disque virtuel amorçable qui se trouve dans l'état Défaillant empêche le système d'exploitation de démarrer. Pour rechercher la cause de ce problème, vérifiez les points suivants : • Déterminez si un ou plusieurs disques physiques d'un disque virtuel non redondant sont défaillants. Si la réponse est « oui », les données sont perdues. Récupérez les données à partir d'une source de stockage de sauvegarde. • Déterminez si deux disques physiques ou plus d'un disque virtuel redondant sont défaillants. Si la réponse est « oui », les données sont perdues. Récupérez les données à partir d'une source de stockage de sauvegarde. REMARQUE : pour RAID 10, si un seul disque physique est défaillant dans chaque ensemble de miroir, le disque virtuel redondant passe à l'état Dégradé mais les données ne sont pas perdues. Si deux disques physiques sont défaillants dans l'un des ensembles de miroir, le disque virtuel redondant passe à l'état Défaillant et les données sont perdues.74 Dépannage Tableau 7-5. Messages d'avertissement : BIOS du contrôleur Dell Inc. PERC S100 ou PERC S300 (suite) Message d'avertissement Mesure corrective WARNING : Found virtual disks that are Degraded and Failed (AVERTISSEMENT : disques virtuels dégradés et défaillants détectés) Ce message d'avertissement apparaît lorsque plusieurs disques virtuels sont en état Dégradé et Défaillant et que Pause if Degraded (Suspendre si dégradé) ou Pause if Failed (Suspendre si défaillant) sont définis sur ON (Activé) dans l'utilitaire de gestion de disques virtuels PERC. Le message suivant apparaît après l'avertissement : --- Press to continue, or to enter setup --- (Appuyez sur Entrée pour continuer, ou sur Ctrl R pour entrer dans la configuration) Appuyez sur pour permettre au système d'exploitation de continuer son démarrage, ou sur pour entrer dans l'utilitaire gestion de disques virtuels PERCet rechercher la cause de la dégradation ou de la défaillance des disques virtuels. REMARQUE : un disque virtuel amorçable qui se trouve dans l'état Défaillant empêche le système d'exploitation de démarrer. Pour en rechercher la cause, vérifiez les points suivants : • Le disque virtuel se trouve-t-il dans l'état Dégradé parce qu'un des disques physiques d'un disque virtuel dans RAID 1 ou RAID 5 est défaillant, ou parce qu'un disque physique d'un disque virtuel dans RAID 10 est défaillant. Appuyez sur et vérifiez que les disques physiques ne sont pas hors ligne ou manquants. Retirez et remplacez le disque physique défaillant. Un deuxième disque physique défaillant peut faire passer un disque virtuel d'un état Dégradé à Défaillant. • Le disque virtuel se trouve-t-il en état Défaillant en raison de la défaillance d'un ou plusieurs disques physiques. Appuyez sur et vérifiez que les disques physiques ne sont pas hors ligne ou manquants. Retirez et remplacez les disques physiques défaillants. Dépannage 75 Tableau 7-6. Messages d'avertissement : BIOS du contrôleur Dell Inc. PERC S100 ou PERC S300 (suite) Message d'avertissement Mesure corrective BIOS NOT INSTALLED - User Disabled INT13 BIOS Load (BIOS non installé - Chargement du BIOS INT13 désactivé par l'utilisateur) Ce message d'avertissement apparaît lorsque : • L'option INT13 Boot Support (Support d'amorçage INT13) a été définie sur OFF (Désactivée) dans l'utilitaire gestion de disques virtuels PERC. Les périphériques amorçables ne fonctionnent pas avec le contrôleur lorsque INT 13 Boot Support est désactivé.(ON(activé) est le paramètre par défaut, ce qui permet aux périphériques amorçables de fonctionner avec le contrôleur). REMARQUE : vous pouvez définir INT 13 Boot Support sur OFF (Désactivé) lorsque vous souhaitez amorcer le système à partir d'un autre périphérique amorçable (par exemple, un autre disque dur). Il vous est recommandé de n'utiliser que le périphérique amorçable de votre système. Si INT 13 Boot Support est défini sur OFF et qu'un autre périphérique d'amorçage n'est pas sélectionné, voilà ce qui se produit : • La séquence d'amorçage s'arrête après l’affichage du message BIOS Not Installed - User Disabled INT 13 BIOS Load. • Un deuxième message d'avertissement apparaît : No boot device available - strike F1 to retry boot, F2 for setup utility, F11 for BIOS boot manager (Aucun périphérique d'amorçage disponible - appuyez sur F1 pour tenter l'amorçage de nouveau, F2 pour l'utilitaire de configuration, F11 pour le gestionnaire d'amorçage du BIOS). 76 Dépannage Lorsque la séquence d'amorçage du système s'arrête, procédez comme suit : 1 Appuyez sur pour quitter la séquence d'amorçage. 2 Mettez votre système hors tension, puis redémarrez-le. 3 Lorsque vous y êtes invité au cours de la séquence de démarrage, appuyez sur pour accéder à l'utilitaire gestion de disques virtuels PERC. 4 Dans le champ Menu principal, descendez à Options du contrôleur à l'aide de la touche fléchée. Appuyez sur . 5 À INT13 Boot Support appuyez sur et passez de OFF à ON. 6 Appuyez sur <Échap>. 7 Dans le champ Menu principal, à l'aide de la touche fléchée descendez à Continue to Boot (Poursuivre le démarrage). Appuyez sur . REMARQUE : la séquence d'amorçage du système continue sur le système d'exploitation. Tableau 7-6. Messages d'avertissement : BIOS du contrôleur Dell Inc. PERC S100 ou PERC S300 (suite) (suite) Message d'avertissement Mesure correctiveDépannage 77 Tableau 7-7. Autres erreurs apparaissant dans le BIOS Problème Causes à considérer Mesures correctives Le RAID 0 passe hors ligne et le RAID 1 passe à l'état dégradé dans un système PowerEdge R210 à deux lecteurs. Disque physique défecteux 1 Démarrer le système dans CTLR-R et remplacer le lecteur défecteux. 2 Supprimer le RAID 0 en panne et en créer un nouveau. Le RAID 0 est optimal et le RAID 1 est toujours dégradé. 3 Installer le système d'exploitation sur le RAID 0 et sauvegarder le RAID 1. 4 Supprimer et recréer le RAID 1 et restaurer les données de sauvegarde. Lorsque vous tentez de mettre à jour le micrologiciel du fond de panier du système et ou le micrologiciel du disque dur à l'aide des fichiers des libellés en double, les mises à jour échouent. Les fichiers de libellés en double ne sont pas pris en charge. Utiliser les utilitaires DOS Les périphériques eSata apparaissent dans l'état Prêt dans CTLR-R Problème de connexion physique Supprimer les périphériques du port eSata et les brancher sur le châssis. REMARQUE : les périphériques eSATA sont exclus de la création de disques virtuels. Au cours de l'amorçage CTRL-R, le S100/S300 n'affiche pas plus de huit disques virtuels. La fonction n'est pas prise en charge. Supprimer tous les disques physiques sauf le(s) dernier(s) ajouté(s). Poursuivre ensuite la suppression des disques virtuels non nécessaires. Souvenez-vous de compter les disques virtuels actuellement utilisés.78 Dépannage Impossible de supprimer les disques virtuels lorsque plus de huit disques virtuels sont présents dans le système. La fonction n'est pas prise en charge. Supprimer tous les disques physiques sauf le(s) dernier(s) ajouté(s). Poursuivre ensuite la suppression des disques virtuels non nécessaires. Souvenez-vous de compter les disques virtuels actuellement utilisés. État de reconstruction des disques virtuels au cours du CTLR-R La reconstruction n'est pas prise en charge dans Ctrl-R. Amorcer à partir d'un système d'exploitation pris en charge. Démarrage de la reconstruction. Pour afficher l'état de la reconstruction, installer une application de stockage prise en charge. L'option rom S100 n'est pas visible lorsque le contrôleur S300 est utilisé avec le système. La coexistence de S100 et S300 dans le même système n'est pas prise en charge. L'option rom S100 est désactivée lorsque S100 et S300 sont disponibles. Supprimer le contrôleur S300 et redémarrer le système pour sélectionner F1 et le RAID pour l'amorçage du BIOS. L'option rom S100 apparaît au cours du démarrage POST. REMARQUE : si les deux contrôleurs sont utilisés dans le système, le Gestionnaire de pilotes Windows affiche le pilote supplémentaire. Tableau 7-7. Autres erreurs apparaissant dans le BIOS Problème Causes à considérer Mesures correctivesDépannage 79 Erreurs liées aux disques virtuels Servez-vous des informations du tableau suivant pour dépanner le contrôleur. Tableau 7-8. Impossible de créer un nouveau disque virtuel Causes à considérer Mesures correctives Le disque physique ne s'affiche pas Cause possible de l'erreur : – Le contrôleur ne peut pas communiquer avec les disques physiques. – Un câble peut être mal branché ou défectueux. Réinstallez les disques physiques dans le fond de panier et vérifiez leurs câbles. Espace disponible insuffisant sur les disques physiques sélectionnés Les disques physiques du disque virtuel doivent disposer de suffisamment d'espace libre. Nombre incorrect de disques physiques sélectionné pour le niveau de RAID souhaité Pour obtenir une description des niveaux de RAID et connaître le nombre de disques physiques acceptable pour chaque niveau de RAID, reportezvous à la section « Comprendre les niveaux de RAID » du Guide technique RAID, disponible sur le site Web de support Dell à l'adresse support.dell.com/manuals. Le disque physique souhaité est indisponible Déterminez si le disque physique : • Est un disque de rechange dédié et ne peut pas être utilisé sur un autre disque virtuel. • Est plein ou ne dispose pas d'une capacité suffisante. Le système possède déjà un maximum de huit disques virtuels Supprimez les disques virtuels non utilisés. PRÉCAUTION : la suppression d'un disque virtuel détruit toutes les données du disque virtuel.80 Dépannage Tableau 7-9. Un disque virtuel est en échec Causes à considérer Mesures correctives Le disque virtuel a perdu un ou plusieurs disques physiques Remplacez les disques physiques défaillants et restaurez les données à partir d'une source de stockage de sauvegarde. Un disque physique du disque virtuel est défaillant ou a été supprimé • Réinstallez le disque physique d'origine s'il a été accidentellement retiré. Effectuez de nouveau un balayage. • Vérifiez l'état des disques physiques du disque virtuel. Remplacez tout disque défaillant, le cas échéant. Récupérez les données à partir d'une source de stockage de sauvegarde. Après toute modification, effectuez de nouveau un balayage pour vérifier si le disque est toujours dans l'état Défaillant. Le disque virtuel a perdu le maximum de disques physiques permis par niveau de RAID Un ou plusieurs disques physiques sont défaillants. – Si le disque virtuel est non redondant, la défaillance d'un seul disque physique peut mettre le disque virtuel en échec. – Si le disque virtuel est redondant, deux disques physiques en échec ou plus peuvent empêcher la reconstruction du disque virtuel. Créer un nouveau disque virtuel Récupérez les données à partir d'une source de stockage de sauvegarde.Dépannage 81 Tableau 7-10. Un disque virtuel est dans l'état Dégradé Causes à considérer Mesures correctives Un disque physique a été retiré • Installez le disque physique d'origine, s'il a été retiré par accident, ou remplacez-le par un disque physique neuf ou non. • Initialisez un nouveau disque physique. Effectuez un nouveau balayage de tous les disques physiques remplacés. • Si le disque physique n'a pas été retiré, vérifiez que ses câbles sont correctement installés. Problèmes mécaniques ou physiques liés au disque physique • Vérifiez si le disque physique du disque virtuel est défaillant. • Si un disque physique a récemment été remplacé ou retiré, vérifiez qu'il est correctement installé dans le fond de panier. Vérifiez les connexions des câbles du disque physique et de la carte mère. Effectuez un nouveau balayage.82 Dépannage Le disque virtuel a perdu de sa redondance • Un ou plusieurs disques physiques présents sur le disque virtuel ont échoué. En raison du ou des disques physiques défaillants, les données du disque virtuel ne sont plus redondantes (mise en miroir ou parité). L'échec d'un autre disque physique entraîne une perte de données. • Remplacez le ou les disques physiques. Reconstruisez le disque physique à l'aide de Storage Management. Reportez-vous à l'écran applicable Storage Management, situé sur le site Web de support Dell à l'adresse support.dell.com/manuals. Métadonnées corrompues sur le disque virtuel 1 Supprimez le disque virtuel sur lequel figurent les métadonnées défecteuses. 2 Attribuez le disque physique en tant que disque de rechange pour reconstruire un disque virtuel redondant. 3 Pour créer un disque virtuel non redondant, supprimez et reconstruisez les données sur un disque virtuel, puis restaurez les données à partir d'une source de stockage de sauvegarde. Tableau 7-10. Un disque virtuel est dans l'état Dégradé Causes à considérer Mesures correctivesDépannage 83 Tableau 7-11. Impossible d'affecter un disque de secours dédié à un disque virtuel Causes à considérer Mesures correctives Le niveau de RAID n'autorise pas la création d'un disque de secours dédié Des disques de secours ne peuvent pas être créés pour les disques virtuels de volumes ou RAID 0. Le disque physique désigné ne dispose pas d'une capacité suffisante pour être un disque de secours dédié La capacité du disque physique sélectionné en tant que disque de secours dédié doit être égale ou supérieure à la capacité du disque physique de plus petite taille du disque virtuel. Par exemple, si le disque physique sélectionné en tant que disque de secours dédié est de 160 Go, et que les disques physiques du disque virtuel sont de 80 Go, 160 Go et 500 Go, un disque de secours dédié peut être affecté car la taille du disque physique sélectionné en tant que disque de secours dédié est supérieure au plus petit disque physique (80 Go) du disque virtuel. Le disque physique fait déjà partie d'un disque virtuel Un disque de secours dédié ne peut pas être affecté à un autre disque virtuel. Les disques physiques sont de types différents Le disque physique utilisé en tant que disque de secours dédié doit être d'un type identique aux disques physiques faisant déjà partie du disque virtuel. Par exemple, si le disque virtuel comprend des disques physiques SATA II, le disque de secours dédié doit être de type SATA II.84 Dépannage Tableau 7-12. Impossible de créer un disque de secours global Causes à considérer Mesures correctives Il n'existe aucun disque physique vide disponible ou les disques physiques n'ont pas été initialisés Installez des disques physiques supplémentaires et initialisez-les. Si les disques physiques existants ont l'état Nouveau, ils doivent être initialisés. AVERTISSEMENT : lorsque vous initialisez un disque physique, toutes les données qu'il contient sont supprimées. REMARQUE : un disque physique dont l'état est Non-Raid peut être initialisé, si on le souhaite, mais il ne sera plus Non-Raid (l'initialisation ajoute des informations de configuration contrôleur PERC S100/ contrôleur PERC S300 au disque physique). Le disque physique fait déjà partie d'un disque virtuel Un disque de secours global ne peut pas être sélectionné s'il fait déjà partie d'un disque virtuel existant. Le disque physique affecté en tant que disque de secours dédié a échoué Lorsque vous y êtes invité au démarrage du système, appuyez sur pour accéder à l'utilitaire gestion de disques virtuels PERC. À l'utilitaire gestion de disques virtuels PERC, sélectionnez Afficher les détails du disque virtuel et appuyez sur . Déterminez si le disque physique désigné en tant que disque de secours global est en état Défaillant. • Vérifiez si le disque physique est défectueux ou physiquement déconnecté. • Sélectionnez un autre disque physique en tant que disque de secours global. Le disque physique affecté en tant que disque de secours global est manquant • Vérifiez si le disque physique a été retiré du fond de panier ou si le câble est déconnecté, ou si les câbles du contrôleur au disque physique sont déconnectés ou défectueux. • Effectuez de nouveau au balayage pour vérifier si les disques physiques sont toujours manquants.Dépannage 85 Erreurs liées aux disques physiques Tableau 7-13. Le disque physique est défaillant Causes à considérer Mesures correctives Un disque physique n'est pas visible dans l'utilitaire de gestion de disques virtuels PERC ou est hors ligne • Vérifiez que les câbles sont connectés correctement. • Pour les contrôleur PERC S300 uniquement : vérifiez que le disque physique est correctement installé dans le fond de panier du système. • Pour les contrôleur PERC S300 uniquement : vérifiez que le fond de panier du système n'est pas endommagé. • Pour les contrôleur PERC S300 uniquement : réinstallez le disque physique et veillez à ce qu'il soit correctement emboîté dans le fond de panier du système. • Effectuez un nouveau balayage, pour (a) mettre à jour l'état des périphériques de stockage reliés au contrôleur, ou (b) corriger une erreur causée par l'effacement ou l'initialisation d'un disque virtuel. Un disque physique est mis en surbrillance en rouge dans l'utilitaire de gestion de disques virtuels PERC • Remplacez le disque physique. En fonction du niveau de RAID du disque virtuel, des données peuvent être perdues. • Effectuez de nouveau un balayage pour confirmer que le nouveau disque a été découvert.86 Dépannage Tableau 7-14. Un disque de secours dédié est défaillant Causes à considérer Mesures correctives Le contrôleur ne peut pas communiquer avec le disque de secours • Vérifiez que le câble du contrôleur au disque physique est correctement connecté. • Veillez à ce que le disque physique soit toujours affecté en tant que disque de secours dédié ou global. • Vérifiez si le disque physique affecté en tant que disque de secours a échoué. Le disque de secours dédié n'est pas visible dans l'utilitaire gestion de disques virtuels PERC ou se trouve hors ligne Le contrôleur ne peut pas communiquer avec le disque de secours • Vérifiez si le disque physique a été retiré ou s'il a échoué. • Vérifiez si un câble n'est pas mal connecté ou défectueux. Tableau 7-15. Le mauvais disque physique a été retiré Causes à considérer Mesures correctives Un disque physique a été retiré d'un disque virtuel Le retrait d'un disque physique d'un disque virtuel entraîne : • Le passage d'un disque virtuel d'un volume ou RAID 0 à l'état Défaillant. • Le passage d'un disque virtuel RAID 1 et RAID 5 à l'état Dégradé. • Le passage d'un disque virtuel RAID 10 à l'état Dégradé (lorsqu'un disque physique est retiré d'un des ensembles mis en miroir). Réinsérez le disque physique retiré et effectuez de nouveau un balayage du disque virtuel.Dépannage 87 Tableau 7-16. Impossible d'initialiser un disque physique Causes à considérer Mesures correctives Le disque physique ne peut pas être initialisé Vérifiez si le disque physique est : • Déjà membre d'un disque virtuel. • Actuellement un disque de secours global ou dédié. • En état Hors ligne. Seuls les disques physiques qui se trouvent en état Prêt peuvent être initialisés.88 DépannageAnnexe A 89 Annexe A Caractéristiques du contrôleur Cette section contient des informations sur les caractéristiques des contrôleurs Dell PowerEdge RAID Controller (PERC) S100 et S300 : • Règles de lecture, écriture et cache • Tâches des disques physiques et virtuels • Caractéristiques des disques virtuels • Niveaux de RAID pris en charge Règles de lecture, écriture et cache Le Tableau A-1 précise les règles de lecture, d'écriture et de cache prises en charge ou non par le contrôleur PERC S100 et le contrôleur PERC S300. PRÉCAUTION : le paramètre par défaut de l'activation du mode d'écriture de cache est Écriture immédiate, sans lecture anticipée (Write Through, Non Read Ahead - WT, NRA). Pour activer la réécriture (Write Back - WB), un système d'alimentation sans coupure est recommandé. Tableau A-1. Règles de lecture, d'écriture et de cache du contrôleur PERC S100 et du contrôleur PERC S300 Catégorie Pris en charge par le contrôleur PERC S100, le contrôleur PERC S300 Paramètres de cache Oui Lecture/écriture Oui Lecture uniquement Oui Aucune (lecture/écriture) Oui90 Annexe A Tâches du contrôleur Le Tableau A-2 précise les tâches prises en charge ou non par le contrôleur PERC S100 et le contrôleur PERC S300. Tâches des disques physiques Le Tableau A-3 précise les tâches des disques physiques prises en charge ou non par les contrôleurs dans l'utilitaire de gestion de disques virtuels PERC . REMARQUE : sauf indication contraire, le terme PERC Virtual Disk Management utility se réfère indifféremment aux utilitaires de gestion de disques virtuels PERC S100 Virtual Disk Management et PERC S300 Virtual Disk Management. Tableau A-2. Tâches des contrôleurs PERC S100 et PERC S300 Nom de tâche de contrôleur PERC S100 ou contrôleur PERC S300 Pris en charge par le contrôleur PERC S100, le contrôleur PERC S300 Activation de l'alarme Non Désactivation de l'alarme Non Alarme silencieuse Non Test de l'alarme Non Définition du taux de vérification de la cohérence Non Rebalayage du contrôleur Non Création de disque virtuel Oui Tableau A-3. Tâches des disques physiques Nom de la tâche du disque physique Pris en charge par le contrôleur PERC S100, le contrôleur PERC S300 Clignotement/arrêt du clignotement Uniquement sur un système équipé d'un contrôleur PERC S300 et d'un fond de panier Attribution et désattribution d'un disque de rechange global OuiAnnexe A 91 Tâches des disques virtuels Le Tableau A-4 précise les tâches des disques virtuels prises en charges ou non par les contrôleurs. Tableau A-4. Tâches des disques virtuels Nom de la tâche du disque virtuel Pris en charge par le contrôleur PERC S100, le contrôleur PERC S300 Attribution et désattribution d'un disque de rechange dédié Oui Création de disque virtuel Oui Reconfiguration Oui Suppression de disque virtuel Oui Démarrage d'une vérification de la cohérence Oui Annulation d'une vérification de la cohérence Oui Initialisation de disque virtuel Non (utilisation du PERC Virtual Disk Management utility) Oui (initialisation en arrière-plan dans Storage Management)92 Annexe A Niveaux de RAID pris en charge Le Tableau A-5 précise les niveaux de RAID pris en charge par le contrôleur PERC S100 et le contrôleur PERC S300. Caractéristiques des disques virtuels Le Tableau A-6 précise les caractéristiques des disques virtuels qui s'appliquent au contrôleur PERC S100 et au contrôleur PERC S300. Tableau A-5. Niveaux de RAID du contrôleur PERC S100 et du contrôleur PERC S300 Niveau de RAID Pris en charge par le contrôleur PERC S100, le contrôleur PERC S300 Volume Oui (uniquement avec l'utilitaire de Gestion de disques virtuels PERC ) RAID 0 Oui RAID 1 Oui RAID 5 Oui RAID 10 Oui Tableau A-6. Caractéristiques des disques virtuels du contrôleur PERC S100 et du contrôleur PERC S300 Caractéristiques des disques virtuels Valeur Nombre maximal de disques virtuels par contrôleur 8 Taille minimale de disque virtuel 102 Mo Taille maximale de disque virtuel Pas de taille maximale ; des limites de taille de système d'exploitation peuvent s'appliquer Nombre maximal de disques physiques par disque virtuel 8 Nombre maximal de disques virtuels par disque physique 8 Nombre maximal de disques physiques pouvant être concaténés Inapplicable Nombre maximal de disques physiques dans un volume 1Annexe A 93 Nombre maximal de disques physiques dans un RAID 0 8 Nombre maximal de disques physiques dans un RAID 1 2 Nombre maximal de disques physiques dans un RAID 5 8 Nombre maximal de disques physiques dans un RAID 10 8 Nombre minimal de disques physiques pouvant être concaténés Inapplicable Nombre minimal de disques physiques dans un volume 1 Nombre minimal de disques physiques dans un RAID 0 2 Nombre minimal de disques physiques dans un RAID 1 2 Nombre minimal de disques physiques dans un RAID 5 3 Nombre minimal de disques physiques dans un RAID 10 4 Tableau A-6. Caractéristiques des disques virtuels du contrôleur PERC S100 et du contrôleur PERC S300 Caractéristiques des disques virtuels Valeur94 Annexe AAnnexe B 95 Annexe B Technologie RAID - Présentation des matrices de disques et des disques virtuels Une matrice de disque est composée de disques physiques connectés à un contrôleur. Un disque virtuel est un stockage de données créé par un contrôleur à partir d'un ou plusieurs disques physiques. Le disque virtuel est affiché par le système d'exploitation en tant que disque seul. Les contrôleurs Dell PowerEdge RAID Controller (PERC) S 100 et PERC S300 offrent les possibilités suivantes : • Des disques physiques AS (Contrôleur PERC S300 uniquement), SATA et ou SSD SATA (Contrôleur PERC S100 uniquement) peuvent coexister sur un seul contrôleur. • Des disques physiques de même type (SAS, SATA, SSD SATA) mais de capacités différentes. • Des disques virtuels peuvent être de niveaux de RAID différents sur le même contrôleur, mais ne sont pas pris en charge sur le même groupe de disques physiques. Certains niveaux de RAID améliorent les performances tandis que d'autres optimisent la fiabilité. Il est donc important d'évaluer vos besoins lorsque vous planifiez la configuration de vos disques virtuels. La capacité d'expansion en ligne du contrôleur des disques virtuels sur plusieurs disques physiques et contrôleurs s'avère extrêmement utile lorsque l'expansion du stockage devient nécessaire.96 Annexe B Présentation des niveaux de RAID Un Contrôleur PERC S100 ou un Contrôleur PERC S300 prend en charge les niveaux de RAID suivants : Tableau B-1. Niveaux de RAID et caractéristiques Niveau de RAID Caractéristiques principales Avantages Volume (peut être créé uniquement à l'aide des utilitaires PERC S100 Virtual Disk Management et PERC S300 Virtual Disk Management. Le Dell OpenManage Server Administrator Storage Management peut gérer un volume mais ne peut pas en créer.) REMARQUE : sauf indication contraire, le terme PERC Virtual Disk Management utility désigne indifféremment les utilitaires PERC S100 Virtual Disk Management et PERC S300 Virtual Disk Management Type de disque virtuel qui relie l'espace disponible sur un disque physique unique et crée un volume logique unique sur lequel des données sont stockées. • La concaténation permet l'accès à un disque physique unique. • La concaténation n'offre pas d'optimisation des performances ni de redondance des données. • Lorsqu'un disque physique d'un disque virtuel concaténé tombe en panne, les données de ce disque virtuel sont perdues. Comme la redondance n'est pas disponible, les données peuvent être restaurées uniquement à partir d'une sauvegarde. RAID 0 (entrelacement) Offre les meilleures performances, mais pas de redondance des données. Les données du disque virtuel sont entrelacées (distribuées) sur deux disques physiques ou plus. Les disques virtuels de RAID 0 sont utiles pour contenir des informations, telles que le fichier de pages du système d'exploitation, lorsque des performances élevées sont requises mais pas de redondance.Annexe B 97 RAID 1 (mise en miroir) Données mises en miroir d'un disque physique sur l'autre pour offrir une redondance de base. Au cas où un seul disque physique tombe en panne, une copie des données existe. Cette copie peut être utilisée pour restaurer les données sur un nouveau disque physique de rechange. Il est utile uniquement lorsque deux disques physiques sont disponibles et lorsque l'intégrité des données est plus importante que la capacité de stockage. RAID 10 (ensembles de données entrelacées mises en miroir) Combine des ensembles de disques mis en miroir et entrelacés ; les données sont entrelacées sur plusieurs ensembles de disques physiques mis en miroir. Le RAID 10 permet la panne de plusieurs disques physiques, jusqu'à un disque physique en panne dans chaque ensemble mis en miroir et entrelacé. Au cas où un seul disque physique tombe en panne (par ensemble mis en miroir), la copie des données existante peut être utilisée pour restaurer les données sur un nouveau disque physique de rechange. • Offre de meilleures performances qu'une simple mise en miroir en raison des disques physiques supplémentaires. • Exige deux fois plus d'espace disque que RAID 0 pour permettre la redondance. • Lorsqu'un disque physique d'un disque virtuel en RAID 10 tombe en panne, le disque virtuel fonctionne toujours. Les données sont lues à partir du disque en miroir restant. Tableau B-1. Niveaux de RAID et caractéristiques (suite) Niveau de RAID Caractéristiques principales Avantages 98 Annexe B État des disques - Disques virtuels et physiques Les tableaux suivants indiquent les différents états de l'utilitaire de gestion de disques virtuels PERC. RAID 5 (entrelacement avec parité) Entrelace les données, ainsi que la parité, sur tous les disques physiques d'un disque virtuel. Les informations de parité sont intercalées dans le disque virtuel. Au cas où un seul disque physique tombe en panne, la parité des données existe sur les disques physiques restants, qui peut être utilisée pour restaurer les données sur un nouveau disque physique de rechange. • Offre des performances de lecture exceptionnelles et la redondance. • Exige uniquement un disque physique supplémentaire pour la redondance. • Pour la plupart des systèmes possédant trois disques physiques ou plus, ce niveau de RAID est tout indiqué. Tableau B-2. États des disques physiques État Définition ATAPI Dénote un périphérique (CD-ROM, DVD ou lecteur de bande) et non un disque physique. Un périphérique ATAPI ne peut pas être initialisé ou ajouté à un disque virtuel. Non-Raid Un disque physique a été déplacé à partir d'un contrôleur différent, autre qu’un Contrôleur PERC S100 ou un Contrôleur PERC S300. Online (En ligne) Le disque physique a été initialisé et fait partie d'un disque virtuel. Ready (Prêt) Le disque physique a été initialisé mais n'est pas utilisé actuellement dans un disque virtuel. Failed (En panne) Un disque physique en panne apparaît comme Failed uniquement lorsque (a) View Virtual Disk Details est sélectionné et (b) le disque virtuel auquel appartient le disque physique est sélectionné. Spare (Rechange) Un disque physique qui est attribué en tant que disque de rechange global ou dédié. Tableau B-1. Niveaux de RAID et caractéristiques (suite) Niveau de RAID Caractéristiques principales Avantages Annexe B 99 États de panne L'état Failed (En panne) ou Degraded (Dégradé) d'un disque virtuel dépend de son niveau de RAID et du nombre de ses disques physiques en panne. Le Tableau B-4 répertorie les modifications de l'état. Si un rebalayage de tous les canaux est exécuté après la déconnexion d’un disque physique, l'état des disques virtuels utilisant le disque physique déconnecté passe de Ready (Prêt) à Failed ou Degraded, en fonction du niveau de RAID du disque virtuel. Pour davantage d'informations sur le rebalayage visant pour mettre à jour les modifications de la configuration de stockage, reportez-vous à la documentation OpenManage disponible sur le site Web de support de Dell à l'adresse support.dell.com/manuals. Tableau B-3. Virtual Disk States State Definition Degraded (Dégradé) Un disque physique d'un disque virtuel redondant est tombé en panne. Des pannes supplémentaires peuvent entraîner une perte de données. Failed (En panne) Un ou plusieurs disques physiques sont en panne. Le disque virtuel est hors ligne. Le disque virtuel ne peut pas restaurer les données. Non-Raid Un disque physique Non-Raid est automatiquement relié à un disque virtuel Non-Raid pour utilisation avec un Contrôleur PERC S100 ou un Contrôleur PERC S300. Normal Un disque virtuel a été créé et son processus de préparation est terminé. Ready (Prêt) Un disque virtuel redondant a été créé et est prêt pour une préparation supplémentaire. Tableau B-4. États de panne par niveau de RAID des disques virtuels Niveau de RAID des disques virtuels État de panne Description RAID 1, RAID 5 Degraded (Dégradé) Un seul disque physique est en panne. RAID 10 Degraded (Dégradé) Un seul disque physique tombe en panne dans un ou plusieurs des ensembles mis en miroir.100 Annexe B Création de disques virtuels : expansion future Lorsque vous créez des disques virtuels, songez à l'éventuel besoin d'expansion de leur capacité dans le futur. Pour un système d'exploitation Microsoft Windows, formatez les disques virtuels avec New Technology File System (NTFS). Microsoft Corporation fournit un utilitaire (diskpart.exe) qui peut étendre dynamiquement un système de fichiers NTFS sur n'importe quel espace adjacent vacant. L'utilisation d'une seule partition par disque virtuel facilite également considérablement l'expansion. REMARQUE : la version de l'utilitaire diskpart.exe dépend de votre version du système d'exploitation Windows. REMARQUE : l'utilitaire diskpart.exe est disponible sur le CD de certaines versions des systèmes d'exploitation Windows ou sur le site Web de Microsoft Corporation (microsoft.com) pour les autres versions. Utilisez la version adaptée à votre système d'exploitation. Volume, RAID 0 Failed (En panne) Un seul disque physique est en panne. RAID 1 ou RAID 5 Failed (En panne) Deux disques physiques ou plus sont en panne. RAID 10 Failed (En panne) Deux disques physiques dans un ensemble mis en miroir sont en panne. Tableau B-4. États de panne par niveau de RAID des disques virtuels Niveau de RAID des disques virtuels État de panne DescriptionAnnexe B 101 Présentation des disques physiques État des disques physiques Au sein des applications de gestion, les disques physiques peuvent faire partie d'un ou plusieurs disques virtuels et peuvent présenter les états suivants : Rebalayage des disques physiques pour modification de l'état Les informations sur les disques physiques affichées dans l'utilitaire de gestion de disques virtuels PERC concernent l'état des disques physiques lors de leur dernier balayage. Si un rebalayage n'a pas été effectué, les informations affichées concernent l'état des disques physiques au démarrage. Chaque fois qu'un disque physique est connecté ou déconnecté lorsqu'il est en ligne, un rebalayage est effectué. Un rebalayage est automatiquement effectué lorsque Dell OpenManage Server Administrator Storage Management détecte qu'un disque physique a été ajouté ou supprimé. Disques de rechange dédiés Un disque de rechange dédié est un disque physique de sauvegarde pour le disque virtuel redondant auquel il est attribué. Le disque physique utilisé en tant que disque de rechange dédié ne peut pas être membre d'un disque virtuel existant. Lorsque le disque de rechange est activé, il devient le réceptacle des données du disque physique en panne du volume, sans interrompre le système et sans intervention de votre part. Un disque de rechange dédié peut être attribué à n'importe quel disque virtuel et jusqu'à quatre disques de rechange peuvent être attribués à un disque virtuel. Toutefois, un disque de rechange dédié ne peut pas être attribué tant qu'une tâche s'exécute sur le disque virtuel. Tableau B-5. Configurations minimales et maximales des disques physiques Niveau de RAID Nombre minimal de disques physiques Nombre maximal de disques physiques RAID 0 2 8 RAID 1 2 2 RAID 10 8 8 RAID 5 3 8102 Annexe B Un disque de rechange global peut être attribué lorsqu'un disque virtuel est créé dans l'utilitaire de gestion de disques virtuels PERC . Un disque de rechange global peut être ajouté à tout moment lors de l'utilisation de Storage Management. Si l'espace disponible du disque de rechange dédié est suffisant, et si un disque tombe en panne, le processus de reconstruction du disque virtuel démarre automatiquement. Les disques de rechange dédiés ne peuvent pas être attribués à un disque virtuel non redondant. REMARQUE : l'état d'un disque virtuel est Failed ou Degraded si un disque physique est en état Failed ou si le câble SAS/SATA du disque physique ou le câble d'alimentation est déconnecté. Un disque de rechange dédié est souvent préféré à un disque de rechange global, particulièrement pour les données critiques. En effet, le disque de rechange dédié garantit au disque virtuel l'attribution unique d'un disque physique de sauvegarde en cas de panne. Pour de plus amples informations, reportez-vous à la section « Gestion des disques de rechange globaux », à la page 63. Disques de rechange globaux Un disque de rechange global est un disque physique de sauvegarde qui peut être utilisé par n'importe quel disque virtuel redondant. Il n'est pas attribué (dédié) à un disque virtuel en particulier. Les disques virtuels peuvent habituellement être reconstruits à l'aide d'un disque de rechange global tant que celui-ci ne fait pas déjà partie d'un disque virtuel et s'il a une capacité disponible suffisante. Contrairement à un disque de rechange dédié, un disque de rechange global peut être attribué à tout moment, même si des tâches sont en cours d'exécution sur les disques virtuels. Si l'espace disponible du disque de rechange global est suffisant, et si un disque tombe en panne, le processus de reconstruction du disque virtuel démarre automatiquement.Annexe C 103 Annexe C Avis réglementaires Les EMI (ElectroMagnetic Interference - perturbations électromagnétiques) correspondent aux signaux et aux émissions, transmis dans l'espace libre ou par conduction sur les câbles d'alimentation ou de signalisation, susceptibles de nuire au fonctionnement du service de radionavigation ou de tout autre service de sécurité, ou encore de dégrader, d'entraver ou d'interrompre de façon répétée le service autorisé de radiocommunication. Les services de radiocommunication comprennent, entre autres, la radiodiffusion commerciale AM/FM, la télévision, les téléphones mobiles, les radars, le contrôle du trafic aérien, les pagers et les SCP (services de communication personnels). Ces services sous licence, au même titre que les émetteurs de radiations non intentionnels comme les périphériques numériques, y compris les ordinateurs, contribuent à l'environnement électromagnétique. La compatibilité électromagnétique est la capacité des éléments d'un équipement électronique à interagir correctement dans l'environnement électronique. Bien que cet ordinateur ait été conçu et certifié conforme aux limites de l'organisme de réglementation concernant les EMI, il n'y a aucune garantie qu'il n'y aura pas de perturbation dans une installation spécifique. Si cet équipement crée des perturbations nuisibles aux services de radiocommunication, ce qui peut être déterminé en l'éteignant puis en le rallumant, essayez de corriger les perturbations en prenant une ou plusieurs des mesures suivantes : • Changez l'orientation de l'antenne de réception. • Déplacez le système par rapport au récepteur. • Éloignez le système du récepteur. • Branchez le système sur une autre prise pour que l'ordinateur et le récepteur soient sur des circuits différents. S'il le faut, consultez un représentant de support technique Dell ou un technicien qualifié en radio/télévision qui pourra vous donner d'autres suggestions. 104 Annexe C Pour plus d'informations sur la réglementation, reportez-vous au Manuel du propriétaire ou au Guide d'utilisation en ligne fourni avec l'ordinateur. Les ordinateurs Dell sont conçus, testés et classés pour l'environnement électromagnétique dans lequel il est prévu de les utiliser. Ces classifications d'environnement électromagnétique font généralement référence aux définitions harmonisées suivantes : • La classe A désigne généralement les environnements professionnels ou industriels. • La classe B désigne généralement les environnements résidentiels. Les équipements informatiques, y compris les périphériques, cartes d'extension, imprimantes, périphériques d'entrée/sortie (E/S), moniteurs, etc., qui sont intégrés ou connectés à l'ordinateur doivent appartenir à la même classification d'environnement électromagnétique que l'ordinateur. Avis concernant les câbles de transmission blindés : afin de réduire la possibilité de perturbation des services de radiocommunication, n'utilisez que des câbles blindés pour connecter des périphériques à un appareil Dell. L'utilisation de câbles blindés assure le maintien de la conformité à la classification de Compatibilité électromagnétique (EMC) appropriée pour l'environnement prévu. Les câbles sont disponibles depuis le site Dell à l'adresse dell.com. La plupart des ordinateurs Dell sont répertoriés pour les environnements de classe B. Cependant, l'inclusion de certaines options peut faire passer certaines configurations à la classe A. Afin de déterminer la classification électromagnétique du système ou de l'appareil, reportez-vous aux sections suivantes spécifiques à chaque organisme de réglementation. Chaque section fournit les informations sur la Compatibilité électromagnétique (EMC)/EMI ou les consignes de sécurité du produit spécifiques à chaque pays.Annexe C 105 Avis de la FCC (États-Unis uniquement) FCC, classe A Ce matériel a été testé et certifié conforme aux limites des appareils numériques de classe A définies par l'alinéa 15 de la réglementation de la FCC. Ces restrictions sont conçues pour fournir une protection adéquate contre les perturbations nuisibles quand le matériel est utilisé dans un environnement commercial. Ce produit crée, utilise et peut émettre de l'énergie de fréquence radio et risque, s'il n'est pas installé et utilisé conformément aux instructions du guide du fabricant, de produire des perturbations nuisibles aux radiocommunications. L'utilisation de ce produit dans une zone résidentielle risque de provoquer des perturbations nuisibles que vous devrez corriger à vos propres frais. FCC, classe B Cet équipement crée, utilise et peut émettre de l'énergie de fréquence radio et peut, s'il n'est pas installé et utilisé conformément aux instructions du guide du fabricant, être la cause de perturbations des réceptions radio et télévisions. Ce matériel a été testé et certifié conforme aux limites des appareils numériques de classe A définies par l'alinéa 15 de la réglementation de la FCC. Cet appareil est conforme à l'alinéa 15 de la réglementation de la FCC. Son fonctionnement est régi par les deux conditions suivantes : • Cet appareil ne doit pas causer de perturbations nuisibles. • Cet appareil doit accepter toutes les perturbations qu'il reçoit, y compris celles susceptibles de perturber son fonctionnement. PRÉCAUTION : les réglementations de la FCC prévoient que les changements ou modifications non explicitement approuvés par Dell Inc. peuvent annuler vos droits à utiliser cet équipement. Ces limites sont conçues pour fournir une protection raisonnable contre les perturbations nuisibles quand l'équipement est utilisé dans un environnement résidentiel. Il n'y a cependant aucune garantie qu'il n'y aura pas de perturbation dans une installation particulière.106 Annexe C Si cet équipement crée des perturbations nuisibles à la réception radio ou télévision, ce qui peut être déterminé en l'éteignant puis en le rallumant, essayez de corriger les perturbations en prenant une ou plusieurs des mesures suivantes: • Changez l'orientation de l'antenne de réception. • Déplacez le système par rapport au récepteur. • Éloignez le système du récepteur. • Branchez le système sur une autre prise pour que l'ordinateur et le récepteur soient sur des circuits différents. Si nécessaire, consultez un représentant de Dell Inc. ou un technicien radio/télévision expérimenté pour des suggestions supplémentaires. Les informations suivantes relatives au ou aux périphérique(s) sont fournies dans ce document en conformité avec la réglementation de la FCC : Industry Canada (Canada uniquement) Industry Canada, classe A Cet appareil numérique de la classe A est conforme à la norme ICES-003 du Canada. Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Industry Canada, classe B Cet appareil numérique de la classe B est conforme à la norme ICES-003 du Canada. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. Nom de produit PERC S100, PERC S300 Raison sociale : Dell Inc. Worldwide Regulatory Compliance & Environmental Affairs One Dell Way Round Rock, Texas 78682, USA 512-338-4400Annexe C 107 PRÉCAUTION : la réglementation d'Industry Canada précise que tout changement ou modification non expressément approuvé par Dell Inc. peut annuler vos droits d'utilisation de cet équipement. Avis CE (Union européenne) Ce symbole indique que ce système Dell est conforme à la directive sur la compatibilité électromagnétique 89/336/EEC et à la directive sur la basse tension 73/23/EEC de l'Union européenne. Un tel marquage indique que ce système Dell est conforme aux normes techniques suivantes : • EN 55022 — « Appareils de traitement de l'information — Caractéristiques des perturbations radioélectriques — Limites et méthodes de mesure ». • EN 55024 — « Appareils de traitement de l'information - Caractéristiques d'immunité - Limites et méthodes de mesure ». • EN 61000-3-2 — « Compatibilité électromagnétique (CEM) - Partie 3 : Limites - Section 2 : Limites pour les émissions de courant harmonique (courant appelé par les appareils inférieur ou égal à 16 A par phase) ». • EN 61000-3-3 — « Compatibilité électromagnétique (CEM) - Partie 3 : Limites - Section 3 : Limitation des fluctuations de tension et du flicker dans les réseaux à basse tension pour les équipements ayant un courant appelé inférieur ou égal à 16 A ». • EN 60950 — « Sécurité des matériels de traitement de l'information ». Les conditions requises par la norme EN 55022 pour les émissions établissent deux classifications : • La classe A s'applique aux zones commerciales typiques. • La classe B s'applique aux zones résidentielles typiques. Pour déterminer la classe de votre ordinateur, examinez l'étiquette des informations FCC ou ICES sur le système ou l'étiquette réglementaire située à l'arrière, sur le côté ou en dessous de l'ordinateur. Si l'étiquette indique la classe B, l'avertissement suivant s'applique à votre ordinateur : Cet appareil Dell est classé pour une utilisation dans un environnement de classe B typique.108 Annexe C Une « Déclaration de conformité » conforme à ces directives et standards a été faite. Elle est disponible auprès de Dell Inc. Products Europe BV, Limerick, Irlande. Avis sur la marque CE Cet équipement répond aux spécifications de la directive européenne 1999/5/EC.Annexe D 109 Annexe D Contacter Dell Aux États-Unis, appelez le 800-WWW-DELL (800-999-3355). REMARQUE : si vous ne disposez pas d'une connexion Internet active, utilisez les coordonnées figurant sur votre preuve d'achat, votre bordereau de marchandises, votre facture ou encore dans le catalogue de produits Dell. Dell propose plusieurs options de maintenance et d'assistance technique en ligne et par téléphone. Leur disponibilité variant d'un pays à l'autre, il est possible que certains services ne soient pas proposés dans votre région. Pour contacter Dell pour des questions ayant trait aux ventes, au support technique ou au service client : 1 Rendez-vous sur le site support.dell.com. 2 Cliquez sur votre pays/région au bas de la page. Pour la liste complète de pays/régions, cliquez sur All (Tous). 3 Cliquez sur Tous les supports dans le menu Support. 4 Sélectionnez le lien de service ou de support approprié en fonction de vos besoins. 5 Pour contacter Dell, sélectionnez la méthode qui vous convient le mieux.110 Annexe DIndex 111 Index A adaptateur PERC S300 installation, 36 aucun périphérique d'amorçage disponible, 75 avis CE (Union européenne), 107 avis de la FCC (États-Unis uniquement), 105 avis réglementaires, 103 avis CE (Union européenne, 107 avis de la FCC (États-Unis uniquement), 105 avis sur la marque CE, 108 Industry Canada (Canada uniquement), 106 avis sur la marque CE, 108 B BIOS du système Dell configuration du jeu de puces, 43 BIOS, fonctions principales, 53 C caratéristiques des disques virtuels, 92 caratéristiques du disque virtuel pour les adaptateurs PERC S100 et PERC S300, 92 caratéristiques, adaptateurs PERC S100 et PERC S300, 67, 89 Configuration de gestion, 51 Configuration et gestion de RAID, 53 continuer à démarrer le système, 66 contrôleur PERC S100, Configuration de gestion, 51 contrôleur PERC S300, Configuration de gestion, 51 couleur des textes, utilitaire PERC S100 Virtual Disk Management utility, utilitaire PERC S300 Virtual Disk Management utility, 55 D décharge électrostatique, protection contre, 9 démarrer le système après utilisation de l'utilitaire de configuration du BIOS, 66112 Index détails du disque physique, affichage, 64 disques de rechange dédiés, 101 globaux, 102 disques de rechange dédiés, 101 disques de rechange globaux, 102 disques de rechange globaux, gérer, 63 disques de rechange, globaux, gestion, 63 disques physiques afficher les détails, 64 connexion au contrôleur PERC S300, 39 dépannage, 85 erreurs, 85 reconstruction automatique, 21 disques physiques, description générale, 26 disques virtuels afficher les détails, 64 changer l'ordre de deux disques, 62 création, extension future, 100 dépannage, 79 description générale, 30 erreurs, 79 initialisation en arrière-plan, 22 migration, 31 prise en charge au démarrage des disques virtuels dégradés, 22 prise en charge de la mémoire cache, 22 transformation, 31 utilitaire PERC S100 Virtual Disk Management utility, utilitaire PERC S300 Virtual Disk Management utility, 54 disques virtuels dégradés, message d'avertissement, 72 disques virtuels hors ligne, message d'avertissement, 73 disques virtuels, les comprendre, 95 documentation connexe, 12 E échange à chaud, 28 erreurs, disques physiques disque de rechange dédié en échec ou en erreur, 86 état En échec affiché, 85 erreurs, disques virtuels disque virtuel supprimé, 84 état En échec, 80 exigences de plate-forme pour les contrôleurs PERC S100, PERC S300, 14 Extension de la capacité en ligne, 25Index 113 F file d'attente des commandes, 23 fonctionnalités des adaptateurs of the PERC S100 et PERC S300, 21 I Industry Canada (Canada uniquement), 106 initialisation du disque physique, 23 initialisation en arrière-plan, 22 initialisation, disque physique, 23 installation adaptateur PERC S300, 36 installation des pilotes de contrôleur, adaptateur PERC S100, 47 installation des pilotes de contrôleur, adaptateur PERC S300, 49 installation du matériel adaptateurs PERC S100 et PERC S300, 35 considérations générales, 35 fin, 39 installation du système d'exploitation et des pilotes, adaptateur PERC S100, 47 installation du système d'exploitation et des pilotes, adaptateur PERC S300, 49 INT13 désactivé, message d'avertissement, 75 itinérance de disque, 29 itinérance de disque physique, 29 J jeux de puces, configuration dans le BIOS du système Dell, 43 L liste de priorité d'amorçage modification, 46 vérification des options du contrôleur, 45 M matrices de disques, les comprendre, 95 message d'avertissement BIOS non installé, chargement du BIOS INT13 désactivé par l'utilisateur, 75 disques virtuels Dégradés trouvés, 72 disques virtuels Hors ligne trouvés, 73114 Index messages d'avertissement écran du BIOS du contrôleur PERC S100, écran du BIOS du contrôleur PERC S300 messages d'avertissement, 71 O OCE, 25 options modification des options du contrôleur, 65 options de contrôleur, les modifier, 65 options de contrôleur, modification, 65 options, contrôleur, 65 P périphérique d'amorçage, message d'avertissement, 75 pilote du contrôleur, procédure de téléchargement, 41 pilotes installation, 47, 49 pilotes de contrôleur, exigences préalables à l'installation, 42 point de contrôle, 23 prise en charge au démarrage, niveaux de RAID, 22 prise en charge de niveau de RAID, 22 procédure d'installation du pilote du contrôleur, 41 protection contre les ESD, 9 R rebalayage recherche de modification de l'état, 101 rebalayer les disques, 65 reconstruction du miroir, 24 règle d'écriture, 89 règle de lecture, 89 règles de cache, 89 remplacement à chaud des disques physiques, 28 S configuration du contrôleur utilisation de l'utilitaire PERC S100, 53 sécurité consignes de sécurité, 7 informations générales, 8 intervention à l'intérieur de votre système, 8 Storport, prise en charge du pilote, 29Index 115 T tâches du contrôleur, prises en charge par les adaptateurs PERC S100 et PERC S300, 90-92 taille des bandes, 30 technologie RAID, 95 tolérance aux pannes, 24 transformation, disques virtuels, 31 U utilitaire PERC S100 Virtual Disk Management utility, utilitaire PERC S300 Virtual Disk Management utility accès, 54 utilitaire PERC Virtual Disk Management utility fonctions principales, 53 V vérification de cohérence, 23 Virtual Disk Management utility, 53116 IndexGlossaire 117 Glossaire ACTIVER L'ÉCRITURE SUR L E CACHE — En mode Activer l'écriture sur le cache, le contrôleur envoie un signal d'achèvement du transfert de données à l'hôte après réception de toutes les données au cours d'une transaction d'écriture de disque par le cache du contrôleur. Le cache du disque virtuel est désactivé par défaut. Il peut cependant être activé par l'utilisateur via l'interface utilisateur. Utiliser le mode Activer l'écriture sur le cache peut entraîner la perte des données en cache en cas de panne d'alimentation avant qu'elles ne soient écrites sur le périphérique de stockage. Ce risque peut être réduit si l'on utilise un UPS (Uninterrupted Power Supply - Bloc d'alimentation sans interruption) sur un système PERC S100 ou S300. Il est recommandé d'utiliser un UPS sur le cache est activé. ADAPTATEUR — Un adaptateur permet au système d'accéder à des périphériques en convertissant le protocole utilisé par un bus ou une interface vers un autre protocole. Il peut également avoir une fonction spécifique. Par exemple, un contrôleur RAID est un type d'adaptateur qui fournit des fonctions RAID. Les adaptateurs peuvent résider sur la carte système ou sur une carte d'extension. Il existe également des adaptateurs réseau et SCSI. AHCI — Spécification de programmation qui définit le fonctionnement des contrôleurs hôte ATA série (également appelés adaptateurs de bus hôte) sans mise en œuvre systématique. Cette spécification décrit une structure de mémoire système pour les vendeurs de matériel informatique qui permet d'échanger des données entre la mémoire du système hôte et des périphériques de stockage reliés. ATA (ADVANCED TECHNOLOGY ATTACHMENT) — Interface standard permettant de connecter les périphériques de stockage d'un système, tels que des lecteurs de CDROM et des disques durs. ATAPI (ATA PACKET INTERFACE) — Interface standard qui définit l'ensemble du protocole entre un système et ses périphériques de stockage internes, tels qu'un lecteur de CD-ROM, de DVD ou de bande. ATAPI fournit un jeu de commandes de périphériques via une interface IDE. BAS (BACKGROUND ARRAY SCAN - BALAYAGE D E L A MATRICE EN ARRIÈREPLAN)) — Background Array Scan est une opération d'arrière-plan qui s'exécute toutes les 100 msec et qui sert à la vérification et la correction des données miroir, de volume et de parité des disques virtuels. BAS s'exécute automatiquement après la création d'un disque virtuel. CANAL — Lien qui transmet des données point à point.118 Glossaire CONFIGURATION NON RAID — Des données non RAID sont des données qui existent déjà sur un disque physique de rechange. Le disque physique non RAID?doit être initialisé avant de pouvoir être utilisé avec le Contrôleur PERC S100 ou Contrôleur PERC S300. CONTRÔLEUR — Puce qui contrôle le transfert de données entre le microprocesseur et la mémoire, ou entre le microprocesseur et un périphérique, comme un disque physique ou le clavier. Pour la gestion du stockage, il s'agit de l'élément matériel ou logique qui interagit avec les périphériques de stockage pour écrire et extraire des données et effectuer la gestion du stockage. Les contrôleurs RAID offrent des fonctions RAID telles que la répartition et la mise en miroir, qui permettent de protéger les données. DÉCOUPAGE SUR PLUSIEURS DISQUES (SPANNING) — Méthode utilisée pour construire les niveaux RAID imbriqués (comme RAID 10) à partir de plusieurs systèmes de niveaux RAID de base (simple). Par exemple, une installation RAID 10 est constituée de plusieurs ensembles de matrices RAID 1, chaque ensemble RAID 1 étant considéré comme un élément du découpage. Les données sont ensuite réparties (RAID 0) sur plusieurs ensembles RAID 1 pour créer un disque virtuel RAID 10. Le découpage sur plusieurs disques (spanning) est généralement utilisé pour faire référence à ces niveaux RAID imbriqués. DEL (DIODE ÉLECTROLUMINESCENTE) — Périphérique électronique qui brille lorsqu'il est sous tension. DÉSACTIVER L'ÉCRITURE SUR L E CACHE — Avec la mémoire cache à écriture immédiate, le contrôleur envoie à l'hôte un signal d'achèvement du transfert des données lorsque le sous-système de disque a reçu toutes les données et a terminé la transaction d'écriture sur disque. DISQUE — Périphérique de stockage de masse non volatile, adressable de façon aléatoire et réinscriptible. Le terme « disque » désigne les périphériques de stockage magnétiques et optiques à rotation, les périphériques de stockage à semi-conducteurs ou les éléments de stockage électroniques non volatiles. DISQUE D E RECHANGE — Disque physique de secours inactif, sous tension, prêt à être utilisé immédiatement en cas de panne d'un disque. Il ne contient pas de données utilisateur. Le disque de rechange peut être dédié à un seul disque virtuel redondant ou faire partie du pool global de disques de rechange disponible pour tous les disques virtuels que gère le contrôleur. En cas de panne d'un disque, le Contrôleur PERC S100 ou Contrôleur PERC S300 remplace automatiquement le disque défectueux par le disque de rechange et reconstruit les données de l'ancien disque. Cette reconstruction ne peut avoir lieu que pour les disques virtuels redondants (RAID 1, 5 ou 10 ; pas RAID 0) et le disque de rechange doit avoir une capacité suffisante. Si le disque de rechange est désigné comme ayant les caractéristiques d'un boîtier, il tente la reconstruction de tout disque défaillant sur le fond de panier au sein duquel il se trouve avant de tenter la reconstruction de disques défaillants sur d'autres fonds de panier.Glossaire 119 DISQUE D E RECHANGE — Disque physique qui remplace un disque physique défectueux d'un disque virtuel. DISQUE PHYSIQUE — Périphérique de stockage de données non volatile à accès aléatoire. Les disques physiques sont réinscriptibles et souvent appelés lecteurs de disque. DISQUE PHYSIQUE EN PANNE — Disque physique qui a cessé de fonctionner, qui fonctionne continuellement de façon incorrecte ou qui est inaccessible. DISQUE VIRTUEL — Un disque virtuel est une zone de stockage créée par un contrôleur RAID à partir d'un ou de plusieurs disques physiques. Bien qu'il soit possible de créer un disque virtuel à partir de plusieurs disques physiques, le système d'exploitation le reconnaît comme un seul disque. Selon le niveau de RAID utilisé, le disque virtuel peut stocker des données redondantes en cas de panne d'un disque. DISQUE VIRTUEL NON REDONDANT — Un disque virtuel non redondant est un disque virtuel dont les disques physiques ne comportent pas de données redondantes pouvant servir à reconstruire un disque physique défectueux. Un disque virtuel RAID 0 est constitué de données réparties sur les disques physiques, sans mise en miroir ni parité pour fournir une redondance. Cela permet un haut débit de données mais n'offre aucune protection en cas de panne d'un disque physique. DISQUE VIRTUEL REDONDANT — Un disque virtuel redondant est un disque virtuel dont les disques physiques comportent des données redondantes pouvant servir à reconstruire un disque physique défectueux. Le disque virtuel peut appliquer la répartition des données sur les disques physiques, la mise en miroir des disques ou la parité pour fournir une redondance. Cela constitue une protection en cas de panne d'un disque physique. ÉQUILIBRAGE D E CHARGE — L'équilibrage de charge est une méthode qui permet de répartir le travail entre deux ordinateurs, liens réseau, UC, lecteurs de disque physique (ou autres ressources) ou plus. Cette méthode sert à optimiser l'utilisation des ressources, le débit ou le temps de réponse. Sur les contrôleurs, la fonction d'équilibrage de charge est assurée par le micrologiciel. Vous pouvez choisir entre l'équilibrage de charge sur chemin unique et l'équilibrage de type «tourniquet». Avec un chemin unique, le micrologiciel peut détecter plusieurs chemins menant à un périphérique et en utiliser un seul pour les activités d'entrées/de sorties (E/S) sur ce périphérique. Le chemin secondaire est utilisé en cas de panne du chemin principal. Si la fonction d'équilibrage de charge du contrôleur est active, le micrologiciel met en place un tourniquet pour l'émission des E/S sur le périphérique à chemins redondants. Le tourniquet émet une commande d'E/S sur le premier chemin, une autre sur le deuxième chemin, etc. Le micrologiciel ne fixe aucune limite quant au chemin à utiliser en premier. En l'absence d'équilibrage de charge, le micrologiciel peut utiliser n'importe lequel des chemins disponibles pour émettre les E/S et il continue normalement à utiliser ce même chemin pour toutes les E/S. Au redémarrage ou en cas d'échec d'un chemin, le micrologiciel choisit à nouveau n'importe lequel des chemins disponibles.120 Glossaire FORMATER — Processus qui consiste à écrire une valeur spécifique dans tous les champs de données d'un disque physique afin d'éliminer les secteurs illisibles ou endommagés. Comme la plupart des disques physiques sont formatés à la fabrication, le formatage n'intervient généralement que si un disque physique génère de nombreuses erreurs de support. GO — Symbole de gigaoctet. Un gigaoctet est égal à 1 024 mégaoctets, soit 1 073 741 824 octets (2^30 octets). GPT : SIGLE D E « GUID PARTITION TABLE », TABLE D E PARTITIONS GUID — Standard pour l'organisation du tableau de partitions d'un disque dur physique. HBA (HOST BU S ADAPTOR - ADAPTATEUR D E BUS HÔTE) — Carte adaptatrice comprenant une logique, un logiciel et un traitement E/S pour gérer le transfert d'informations entre le système hôte et les périphériques qui y sont connectés. HORS LIGNE — Un disque physique est hors ligne lorsqu'il fait partie d'un disque virtuel, mais que ses données ne sont pas accessibles pour le disque virtuel. IDENTIFICATEUR GLOBAL UNIQUE (GUID) — Identificateur chiffré de référence unique utilisé dans les applications logicielles. INITIALISATION — Processus qui consiste à écrire des zéros dans les champs de données d'un disque virtuel et, pour les niveaux RAID avec tolérance aux pannes, à générer la parité correspondante pour mettre le disque virtuel à l'état Ready (Prêt). L'initialisation génère des informations de parité, de sorte que le disque virtuel est redondant. Les disques virtuels peuvent fonctionner sans initialisation, mais ils ne deviennent vraiment redondants qu'une fois l'initialisation effectuée. INITIALISATION EN ARRIÈRE-PLAN — L'initialisation en arrière-plan désigne la recherche automatique des erreurs de support sur les disques physiques. Cette opération garantit que les segments de données répartis sont identiques sur tous les disques physiques d'un disque virtuel. La différence entre l'initialisation en arrièreplan et la vérification de cohérence est que la première est exécutée automatiquement pour les nouveaux disques virtuels. Elle commence automatiquement après la création du disque. INT 13H — Interruption DOS utilisée pour activer les fonctions de recherche, de lecture, d'écriture et de formatage de disque. L'interface Int 13h prend en charge les disques physiques contenant jusqu'à un espace disque maximum d'environ 8,45 GB. ITINÉRANCE D E DISQUE — Déplacement de disques d'un logement vers un autre sur un contrôleur. JBOD (JUST A BUNCH O F DISKS [DRIVES]) — Sous-système de stockage qui utilise des lecteurs de disques indépendants simples ou multiples. MATRICE D E DISQUES — Groupement de disques physiques connectés au contrôleur RAID. Le contrôleur RAID peut regrouper les disques physiques d'un ou de plusieurs canaux en une matrice. Glossaire 121 MATRICES D E STOCKAGE — Entité de stockage gérée entièrement par le logiciel de gestion de stockage. Matrice de stockage comprenant plusieurs composants physiques (lecteurs, contrôleurs, ventilateurs et blocs d'alimentation) et des composants logiques (tels que des disques virtuels). Une matrice de stockage peut s'étendre sur plusieurs boîtiers physiques. MÉMOIRE CACHE — Mémoire rapide qui stocke les données auxquelles le système a récemment accédé. L'utilisation du cache accélère les accès suivants aux mêmes données. Il s'applique le plus souvent à l'accès à la mémoire du processeur, il peut également servir à stocker une copie des données accessibles sur un réseau. Lorsque les données sont lues ou écrites dans la mémoire principale, une copie est enregistrée dans le cache avec l'adresse mémoire principale associée. Le logiciel de mémoire cache surveille les adresses des lectures suivantes afin de voir si les données demandées sont déjà présentes dans le cache. Si celles-ci se trouvent déjà dans la mémoire cache (un succès cache), elles sont immédiatement lues depuis la mémoire cache et la lecture de mémoire principale est annulée (ou ne démarre pas). Si les données ne se trouvent pas dans la mémoire cache (un échec cache), elles sont extraites de la mémoire principale et enregistrées dans la mémoire cache. MICROLOGICIEL — Logiciel stocké dans la mémoire morte (ROM) ou la mémoire morte programmable (PROM). Le micrologiciel détermine souvent le comportement d'un système lors de son premier démarrage. Exemple typique de micrologiciel : programme de contrôle d'un système, qui charge l'intégralité du système d'exploitation à partir du disque ou d'un réseau, puis passe le contrôle au système d'exploitation. MIGRATION D E DISQUE — La migration de disques signifie le déplacement d'un disque virtuel ou d'un disque de rechange d'un contrôleur sur un autre en déconnectant les disques physiques et en les reliant au nouveau contrôleur. MISE EN CACHE (CACHING) — Processus consistant à utiliser un tampon de mémoire haut débit appelé «cache» afin d'accélérer les performances globales de lecture et d'écriture. Les accès à ce cache sont plus rapides que les accès au soussystème de disque. Pour améliorer les performances de lecture, le cache contient généralement les dernières données auxquelles vous avez accédé, ainsi que celles résidant dans les secteurs de disque adjacents. Pour améliorer les performances d'écriture, le cache peut temporairement stocker les données conformément à ses politiques d'activation de l'écriture sur le cache. Pour en savoir plus, voir la définition de l'activation de l'écriture sur le cache. MISE EN MIROIR — Processus consistant à fournir une redondance totale des données en gérant deux disques physiques qui sont l'exacte copie l'un de l'autre. En cas de panne d'un disque physique, le contenu de l'autre peut servir à maintenir l'intégrité du système et à reconstruire le disque défectueux. MO — Symbole de mégaoctet. Le terme mégaoctet correspond à 1 048 576 octets (2^20 octets); cependant, lorsqu'il s'agit du stockage sur disque dur, cette mesure est souvent arrondie et équivaut à 1 000 000 octets.122 Glossaire NAS (NETWORK ATTACHED STORAGE - STOCKAGE RÉSEAU) — Serveur qui exécute un système d'exploitation pour traiter des fichiers, et qui est accessible directement sur un LAN via des protocoles tels que TCP/IP. NCQ (NATIVE COMMAND QUEUING) — Protocole de commande pour les périphériques ATA série qui permet à plusieurs commandes non exécutées d'être actives simultanément sur le lecteur. NIVEAUX D E RAID — Ensemble de techniques appliquées aux disques physiques d'un disque virtuel pour une grande disponibilité des données, et/ou des caractéristiques de performances pour les environnements hôtes. Vous devez affecter un niveau RAID à chaque disque virtuel. NS — Symbole de nanoseconde, soit un milliardième de seconde. NTFS (NEW TECHNOLOGY FILE SYSTEM) — Système de fichiers utilisé par les systèmes d'exploitation Microsoft Windows. OCE (ONLINE CAPACITY EXPANSION) — Opération consistant à ajouter de la capacité à un disque virtuel existant en lui ajoutant un disque physique supplémentaire alors que le système hôte est actif et sans perturber la disponibilité des données. ONLINE (EN LIGNE) — Un périphérique en ligne est un périphérique accessible. PARITÉ — Bit supplémentaire ajouté à un octet ou à un mot pour révéler les erreurs de stockage (en mémoire RAM ou sur disque) ou de transmission. La parité permet de générer un ensemble de données de redondance à partir de deux ensembles de données parents ou plus. Les données de redondance permettent de reconstruire l'un des ensembles de données parents. Toutefois, les données de parité ne dupliquent pas entièrement les ensembles de données parents. Dans un système RAID, cette méthode est appliquée à des disques physiques entiers ou aux éléments de bande de tous les disques physiques d'un disque virtuel. La parité peut être dédiée, ce qui signifie que la parité des données sur deux disques physiques ou plus est stockée sur un disque physique différent. Elle peut également être distribuée, ce qui signifie que les données de parité sont réparties sur tous les disques physiques du système. En cas d'échec d'un seul disque physique, vous pouvez le reconstruire à partir de la parité des données applicables sur les autres disques physiques. PARITÉ DISTRIBUÉE — La parité inclut un bit supplémentaire, ajouté à un octet ou à un mot pour révéler les erreurs de stockage (en mémoire RAM ou sur disque) ou de transmission. La parité permet de générer un ensemble de données de redondance à partir de deux ensembles de données parents ou plus. Les données de redondance permettent de reconstruire l'un des ensembles de données parents. Avec la parité distribuée, les données de parité sont réparties sur tous les disques physiques du système. En cas d'échec d'un seul disque physique, vous pouvez le reconstruire à partir de la parité des données applicables sur les autres disques physiques. PARTITION — Structure logique sur un segment contigu d'espace de stockage d'un disque physique ou virtuel reconnu par un système d'exploitation.Glossaire 123 PCIE (PERIPHERAL COMPONENT INTERCONNECT EXPRESS) — Interconnexion périphérique à haut débit qui peut être utilisée pour des transferts gigabit et puce à puce. PNP (PLUG AND PLAY) — Technologie qui permet la reconnaissance automatique des cartes et périphériques d'interface lorsqu'elle est branchée sur un PC. PORT — Point de connexion sur un contrôleur RAID, un lecteur de disque, un boîtier ou un autre périphérique. RAID (REDUNDANT ARRAY O F INDEPENDENT DISKS - MATRICE REDONDANTE D E DISQUES INDÉPENDANTS) — Matrice constituée de plusieurs disques physiques indépendants gérés ensemble pour offrir une meilleure fiabilité et/ou des performances supérieures à celles obtenues avec un seul disque physique. Le disque virtuel est reconnu par le système d'exploitation comme une unité de stockage unique. Les entrées/sorties sont plus rapides, car le système peut accéder simultanément à plusieurs disques. Les niveaux de RAID redondants (1, 5 et 10) fournissent un mécanisme de protection des données. RECONSTRUCTION — Régénération de toutes les données sur un disque de rechange dans un disque virtuel redondant (RAID 1, 5 et 10) après une panne du disque physique. La reconstruction du disque se produit normalement sans aucune interruption du fonctionnement normal du disque virtuel concerné, bien que vous puissiez parfois constater une dégradation des performances du sous-système de disque. REDONDANCE — Installation de plusieurs composants interchangeables remplissant la même fonction, afin de gérer les pannes et les erreurs. Les formes courantes de redondance matérielle sont la mise en miroir des disques, la mise en place de disques de parité ou la parité distribuée. REMPLACEMENT À CHAUD — Remplacement d'un composant défectueux alors que le système est en cours d'exécution et fonctionne normalement. RÉPARTITION (STRIPING) — La répartition de disques consiste à écrire les données en les répartissant sur tous les disques physiques qui composent un disque virtuel. Chaque bande de répartition correspond à une plage d'adresses de données sur le disque virtuel. Ces adresses sont associées par adressage séquentiel (sous forme d'unités de taille fixe) à chaque disque physique membre du disque virtuel. Par exemple, si le disque virtuel comprend cinq disques physiques, la bande de répartition écrit des données sur les disques physiques un à cinq sans aucune répétition sur deux disques. La quantité d'espace occupée par une bande est la même sur chaque disque physique. La portion des données réparties qui réside sur un disque physique est un élément de bande. La segmentation en elle-même ne fournit aucune redondance des données, sauf si elle est associée à un mécanisme de parité.124 Glossaire SAN (STORAGE AREA NETWORK - RÉSEAU D E STOCKAGE) — Réseau hautes performances, habituellement de niveau entreprise qui relie des sous-systèmes de stockage de disques à des serveurs. Les périphériques de stockage sont accessibles à plusieurs hôtes simultanément. SAS (SERIAL ATTACHED SCSI) — Extension de la norme SCSI définissant une interface série point à point pour la connexion de périphériques. L'interface SAS offre différents avantages : amélioration des performances, câblage simplifié, utilisation de connecteurs plus petits et d'un nombre de broches réduit, et consommation inférieure à celle de SCSI parallèle. Les disques physiques SAS sont pris en charge uniquement par le Contrôleur PERC S300. SATA (SERIAL ADVANCED TECHNOLOGY ATTACHMENT - CONNEXION PAR TECHNOLOGIE SÉRIE AVANCÉE) — Norme d'interface de stockage physique désignant une liaison série qui fournit des connexions point à point entre différents périphériques. Elle utilise des câbles série plus fins qui permettent une meilleure ventilation de l'intérieur du système et l'utilisation de châssis plus petits. Les contrôleurs Contrôleur PERC S100 et Contrôleur PERC S300 exploitent une interface de connexion électrique et physique courante qui est compatible avec la technologie SATA série. SCSI (SMALL COMPUTER SYSTEM INTERFACE - INTERFACE SYSTÈME POUR MICROORDINATEUR) — Standard qui permet à plusieurs périphériques de se connecter sous forme de guirlande. Les disques durs les plus rapides utilisent le SCSI plutôt que le IDE. SPARE (RECHANGE) — Disque physique capable d'en remplacer un autre lorsqu'il tombe en panne. SSD (SOLID STATE DISK - DISQUE ÉLECTRONIQUE) — Support de stockage hautes performances qui ne contient pas de parties amovibles. Il contient une carte mémoire, un bus de carte mémoire, une UC et une carte de batterie. STORPORT — Le pilote Storport a été conçu pour remplacer le pilote SCSIport sous Windows 2003 et supérieur. De plus, il permet d'augmenter les performances des nouveaux protocoles de contrôleur RAID (comme SAS), en fournissant un débit d'entrées/de sorties supérieur, une plus grande facilité de gestion et une interface sur port miniature mise à niveau. Par exemple, alors que le pilote SCSIport autorise un maximum de 254 commandes par contrôleur, Storport prend en charge le même nombre de commandes par unité logique (LUN). SYSTÈME HÔTE — Tout système sur lequel le contrôleur RAID est installé. Le système hôte peut être un gros système, une station de travail ou un ordinateur personnel. TO (TÉRAOCTET) — Un millier de gigaoctets (environ un trillion d'octets).Glossaire 125 TOLÉRANCE AUX PANNES — Capacité du sous-système de disques à subir une panne d'un seul lecteur de disque physique dans un disque virtuel sans compromettre l'intégrité des données et les capacités de traitement. Le Contrôleur PERC S100 et le Contrôleur PERC S300 fournissent cette prise en charge via les disques virtuels redondants des niveaux de RAID 1, 5 et 10. La tolérance aux pannes est souvent associée à la disponibilité du système, car elle permet au système de rester disponible pendant les pannes de lecteur. En cas d'échec de disque, le Contrôleur PERC S100 et Contrôleur PERC S300 prennent en charge les disques de rechange et la fonction de reconstruction automatique. TRANSFORMATION — Une transformation peut signifier : (1) extension de capacité, à l'aide de OCE (ajout de plus de disques physiques à un disque virtuel et augmentation de la capacité de stockage du ou des disques virtuels), ou (2) reconstruction (reconstruction de données sur le disque virtuel à partir d'un disque virtuel redondant ou d'un disque de rechange ou d'un disque physique de sauvegarde). UTILITAIRE D E CONFIGURATION D U BIOS (SYSTÈME D'E/S D E BASE) — Autre nom de l'utilitaire Gestion de disques virtuels PERC . Il apparaît au cours du démarrage du système par une pression sur les touches . UTILITAIRE D E GESTION D E RAID — Un utilitaire de gestion de RAID (utilitaire Gestion de disques virtuels PERC ) est employé pour configurer des disques physiques et des disques virtuels. Utilisez l'utilitaire Gestion de disques virtuels PERC si le système d'exploitation n'a pas encore été installé sur le contrôleur. UTILITAIRE PERC S100 VIRTUAL DISK MANAGEMENT, PERC S300 VIRTUAL DISK MANAGEMENT UTILITY — L'utilitaire PERC S100 Virtual Disk Management ou PERC S300 Virtual Disk Management (l'utilitaire PERC Virtual Disk Management utility) configure et maintient les disques virtuels RAID et gère le système RAID. Comme il réside dans le BIOS du contrôleur, il fonctionne indépendamment du système d'exploitation de votre installation. L'utilitaire Gestion de disques virtuels PERC , accessible par une pression sur au démarrage du système, est construit sur des éléments appelés des commandes dont chacun exécute une fonction spécifique. Ces fonctions incluent des procédures que vous pouvez exécuter pour configurer des disques physiques et des disques virtuels. L'utilitaire Gestion de disques virtuels PERC est différent du BIOS du système Dell Inc., qui contient les paramètres du BIOS de chaque plateforme Dell et est accessible en appuyant sur au cours du démarrage du système. VÉRIFICATION D E COHÉRENCE — Opération servant à vérifier que toutes les bandes d'un disque virtuel avec un niveau RAID redondant sont cohérentes; elle permet aussi de corriger les erreurs éventuelles. Pour les matrices RAID 5, un contrôle de cohérence vérifie la parité des données sur chaque bande. Pour les matrices RAID 1 et RAID 10, cette opération vérifie que les données en miroir sont correctes pour chaque bande. WHQL (WINDOWS HARDWARE QUALITY LABS - LABORATOIRES D E QUALITÉ MATÉRIELLE WINDOWS) — Entité de Microsoft Corporation qui teste les services du matériel et des pilotes de périphériques non-Microsoft, pour s'assurer de leur conformité et de leur compatibilité avec les systèmes d'exploitation Microsoft. 126 Glossaire Guide d'utilisation du système Dell™ PowerConnect™ 5324 Présentation Description matérielle Installation du périphérique PowerConnect Mise en route et configuration du périphérique Utilisation de Dell OpenManage Switch Administrator Configuration des informations système Configuration des informations du périphérique Affichage des statistiques Configuration de la qualité de service Caractéristiques techniques Glossaire Remarques, avis et précautions Les informations contenues dans ce document sont sujettes à modification sans préavis. © 2003 - 2007 Dell Inc. Tous droits réservés. La reproduction de ce document, de quelque manière que ce soit, sans l'autorisation écrite de Dell Inc. est strictement interdite. Marques utilisées dans ce document : Dell, Dell OpenManage, le logo DELL, Inspiron, Dell Precision, Dimension, OptiPlex, PowerConnect, PowerApp, PowerVault, Axim, DellNet et Latitude sont des marques de Dell Inc. Microsoft et Windows sont des marques déposées de Microsoft Corporation.  D'autres marques et noms commerciaux peuvent être utilisés dans ce document pour faire référence aux entités se réclamant de ces marques et de ces noms ou à leurs produits.  Dell Inc. rejette tout intérêt propriétaire dans les marques et les noms commerciaux autres que les siens. Mai 2007 REMARQUE : Une REMARQUE indique une information importante qui peut vous aider à mieux utiliser votre ordinateur.  AVIS : Un AVIS vous avertit d’un risque de dommage matériel ou de perte de données et vous indique comment éviter le problème.  PRÉCAUTION : Une PRÉCAUTION indique un risque potentiel de dommages matériels ou corporels, ou de mort.Retour à la page du sommaire Mise en route et configuration du périphérique  Guide d'utilisation du système Dell™ PowerConnect™ 5324 Configuration du terminal Amorçage du périphérique Présentation de la configuration Configuration initiale Nom d'utilisateur Chaînes de communauté SNMP Configuration avancée Récupération d'une adresse IP à partir d'un serveur DHCP Réception d'une adresse IP à partir d'un serveur BOOTP Gestion de la sécurité et configuration du mot de passe Configuration de mots de passe de sécurité Procédures de démarrage Une fois toutes les connexions externes terminées, vous devez connecter un terminal au périphérique pour configurer celui-ci et effectuer différentes  procédures. Pour la configuration initiale, une configuration de périphérique standard est réalisée.  Figure 4-12. Organigramme des procédures d'installation et de configuration Configuration du terminal Pour configurer le périphérique, le terminal doit exécuter un logiciel d'émulation de terminal. Assurez-vous que le logiciel d'émulation de terminal est configuré de la façon suivante : 1. Sélectionnez le port série approprié (port série 1 ou 2) à relier à la console.  2. Configurez le taux de transfert des données à 9600 bauds.  REMARQUE : Avant de continuer, lisez les notes de mise à jour pertinentes à ce produit. Les notes de mise à jour peuvent être téléchargées sur le site  www.support.dell.com. 3. Configurez le format de données à 8 bits de données, 1 bit d'arrêt et aucune parité.  4. Paramétrez le contrôle du flux sur none (aucun). 5. Sous Propriétés, sélectionnez le mode VT100 pour émulation. 6. Sélectionnez Touches du terminal pour les touches de fonction, de direction et Ctrl. Assurez-vous que le paramètre est configuré sur Touches du terminal (et non sur Touches Windows). Amorçage du périphérique ¡ Le périphérique est fourni avec une configuration par défaut. ¡ Le périphérique n'est pas configuré avec un nom d'utilisateur et un mot de passe par défaut. Pour amorcer le périphérique, procédez comme suit : 1. Assurez-vous que le port série du périphérique est connecté à un terminal ASCII ou au connecteur série d'un système de bureau exécutant un logiciel  d'émulation de terminal.  2. Trouvez une prise secteur. 3. Éteignez la prise secteur.  4. Connectez le périphérique sur la prise secteur. Reportez-vous à la section «Connexion d'un périphérique sur un bloc d'alimentation». 5. Allumez la prise secteur. Lorsque le périphérique est mis sous tension alors que le terminal local est déjà connecté, il effectue un POST (auto-test de démarrage). Le POST s'effectue  chaque fois que le périphérique est initialisé et vérifie les composants matériels afin de déterminer si le périphérique fonctionne totalement avant de  poursuivre l'initialisation. Si un problème critique est détecté, le flux du programme s'arrête. Si le POST est exécuté avec succès, une image exécutable valide  est chargée dans la mémoire RAM. Les messages de POST qui s'affichent sur le terminal indiquent la réussite ou l'échec du test. 1. Assurez-vous que le câble ASCII est connecté au terminal et que les paramètres sur l'émulation de logiciel sont configurés correctement.  2. Connectez le bloc d'alimentation au périphérique.  3. Mettez le périphérique sous tension.  4. À l'amorçage du périphérique, le test d'amorçage recense tout d'abord la mémoire disponible, puis continue le processus d'amorçage. Vous trouverez cidessous un exemple des informations qui s'affichent lors du POST : ------ Auto-test de démarrage (POST) ------ Test bouclage canal UART.......................................OK Test SDRAM système.............................................OK  Test Somme de Contrôle Amorçage1...............................OK  Test Somme de Contrôle Amorçage2...............................OK  Test Validation Image Flash....................................OK Version logiciel AMORÇAGE 1.0.0.20 Créée le 22-Jan-2004 15:09:28 AVIS : Lorsque vous utilisez HyperTerminal avec le système d'exploitation Microsoft® Windows 2000, assurez-vous d'avoir préalablement installé  Windows® 2000 Service Pack 2 ou une version plus récente. Windows 2000 Service Pack 2 vous permet d'utiliser les touches de direction dans  l'émulation HyperTerminal VT100. Rendez-vous à l'adresse www.microsoft.com pour obtenir des informations sur les service packs de Windows 2000.  REMARQUE : Les données conventionnelles pour l'amorçage sont les suivantes : Processeur : FireFox 88E6218 ARM946E-S , 64 Mo SDRAM. I-Cache 8 Ko. D-Cache 8 Ko. Cache activé.  Amorçage automatique dans 2 secondes - appuyez sur RETOUR ou Échap pour abandonner et accéder à la mémoire PROM.  Préparation à la décompression...  Le processus d'initialisation dure environ 90 secondes. Le message d'amorçage automatique qui apparaît à la fin du POST (voir les dernières lignes ci-dessus) indique qu'aucun problème n'a été rencontré.  Au cours de l'amorçage, le menu Démarrer peut être utilisé pour exécuter des procédures particulières. Pour accéder au menu Démarrer, appuyez sur <Échap> ou  moins de deux secondes après l'affichage du message d'amorçage automatique. Si le processus d'amorçage du système ne s'arrête pas lorsque vous appuyez sur <Échap> ou , le processus continue à décompresser et à charger  le code dans la RAM. Le code démarre à partir de la mémoire RAM et la liste des numéros de port disponibles ainsi que leur état (disponible ou non disponible)  s'affichent. L'écran suivant est un exemple de configuration. Les éléments tels que les adresses, les versions et les dates peuvent être différents pour chaque  périphérique. Décompression logiciel à partir d'image-2 78c000 OK Exécution depuis mémoire RAM...  ********************************************************************* *** Exécution logiciel Ver. 1.0.0.15 Date 03-Mar-2004 Heure 10:41:14 *** ********************************************************************* Version matériel : 00.01.07  Adresse MAC Base : 00:00:07:77:77:77 Taille DRAM : 64 Mo Taille premier bloc DRAM : 40 960 Ko Premier PTR DRAM : 0x1800000 Taille mémoire Flash : 16 Mo  Configuration périphérique :  Système basé sur Prestera  Emplacement 1 - Neyland24 HW Rév. 0.1  Version Tapi : v1.2.9 Version Noyau : v1.2.9 01-Jan-2000 01:01:32 %INIT-I-InitCompleted: Initialisation terminée  console> 01-Jan-2000 01:01:35 %LINK-W-Down: g1 01-Jan-2000 01:01:35 %LINK-W-Down: g2 01-Jan-2000 01:01:35 %LINK-W-Down: g3 01-Jan-2000 01:01:35 %LINK-W-Down: g4 01-Jan-2000 01:01:35 %LINK-W-Down: g5 01-Jan-2000 01:01:35 %LINK-W-Down: g6 01-Jan-2000 01:01:35 %LINK-W-Down: g7 01-Jan-2000 01:01:35 %LINK-W-Down: g8 01-Jan-2000 01:01:35 %LINK-W-Down: g9 01-Jan-2000 01:01:35 %LINK-W-Down: g10 01-Jan-2000 01:01:35 %LINK-W-Down: g11 01-Jan-2000 01:01:35 %LINK-W-Down: g12 01-Jan-2000 01:01:35 %LINK-W-Down: g13 01-Jan-2000 01:01:36 %LINK-W-Down: g14 01-Jan-2000 01:01:36 %LINK-W-Down: g15 01-Jan-2000 01:01:36 %LINK-W-Down: g16 01-Jan-2000 01:01:36 %LINK-W-Down: g17 01-Jan-2000 01:01:36 %LINK-W-Down: g18 01-Jan-2000 01:01:36 %LINK-W-Down: g19 01-Jan-2000 01:01:36 %LINK-W-Down: g20 01-Jan-2000 01:01:36 %LINK-W-Down: g21 01-Jan-2000 01:01:36 %LINK-W-Down: g22 01-Jan-2000 01:01:36 %LINK-I-Up: VLAN 3000 01-Jan-2000 01:01:36 %LINK-I-Up: VLAN 1 01-Jan-2000 01:01:36 %LINK-I-Up: g1 01-Jan-2000 01:01:36 %LINK-I-Up: g13 01-Jan-2000 01:01:36 %LINK-I-Up: g14 01-Jan-2000 01:01:36 %LINK-I-Up: g19 01-Jan-2000 01:01:36 %LINK-I-Up: g20 01-Jan-2000 01:01:36 %LINK-I-Up: g21 01-Jan-2000 01:01:36 %LINK-W-Down: g23 01-Jan-2000 01:01:36 %LINK-W-Down: g24 01-Jan-2000 01:01:36 %LINK-W-Down: canal1 01-Jan-2000 01:01:36 %LINK-I-Up: VLAN 1000 01-Jan-2000 01:01:36 %TRUNK-I-PORTADDED: Port g24 ajouté à canal1  01-Jan-2000 01:01:36 %LINK-I-Up: g22 01-Jan-2000 01:01:36 %LINK-I-Up: g23 01-Jan-2000 01:01:36 %LINK-I-Up: g24 01-Jan-2000 01:01:36 %LINK-I-Up: canal1 01-Jan-2000 01:01:36 %LINK-W-Down: g1 01-Jan-2000 01:03:42 %INIT-I-Startup: Démarrage à froid  console> Lorsque le périphérique démarre correctement, une invite système permettant de configurer le périphérique s'affiche (console>). Avant de configurer le périphérique, assurez-vous que vous y avez installé la dernière version du logiciel. Si nécessaire, téléchargez et installez la dernière version. Pour plus  d'informations sur le téléchargement de la dernière version, reportez-vous à la section «Téléchargement des logiciels». Présentation de la configuration Avant d'affecter une adresse IP statique au périphérique, récupérez les informations suivantes : l L'adresse IP spécifique qui a été affectée au périphérique pour qu'il soit configuré. l Le chemin par défaut. l Le masque du réseau. Il existe deux types de configuration : l Configuration initiale — Fonctions de base en matière de configuration et de sécurité. l Configuration avancée — Inclut la configuration de l'adresse IP dynamique et des fonctions de sécurité plus évoluées. console# copy running-config startup-config Configuration initiale REMARQUE : Si vous modifiez la configuration, vous devez l'enregistrer avant de redémarrer le système. Pour enregistrer la configuration, entrez : ¡ Le périphérique PowerConnect n'a jamais été configuré et est dans le même état que lorsqu'il a été reçu. ¡ L'initialisation du périphérique PowerConnect a réussi. ¡ La connexion série est établie et l'invite de console s'affiche à l'écran d'un terminal VT100. (Appuyez plusieurs fois sur la touche  pour  vérifier que l'invite s'affiche correctement.) ¡ Le périphérique n'est pas configuré avec un nom d'utilisateur et un mot de passe par défaut. La configuration initiale du périphérique se fait via le port série. Après la configuration initiale, le périphérique peut être géré soit par le port série déjà  connecté, soit à distance via une interface définie pendant la configuration initiale. La configuration initiale consiste à : l Paramétrer le nom d'utilisateur 'admin', le mot de passe 'dell' avec le plus haut niveau de privilège : 15. l Configurer l'adresse IP statique et la passerelle par défaut. l Configurer la chaîne de communauté SNMP de lecture/écriture. l Affecter l'adresse IP allouée par le serveur DHCP. Avant d'effectuer la procédure de configuration initiale du périphérique PowerConnect, récupérez les informations suivantes auprès de l'administrateur de  réseau : l L'adresse IP à affecter à un VLAN par lequel le périphérique est géré. l Le masque de sous-réseau IP du réseau. l L'adresse IP passerelle par défaut. l La communauté SNMP. Adresse IP statique et masque de sous-réseau  L'adresse IP peut être configurée sur n'importe quelle interface, comme un VLAN, un LAG ou un port physique. Une fois la commande de configuration saisie, il  est recommandé de vérifier qu'un port a été configuré avec l'adresse IP en saisissant la commande show ip interface. Important : Si une adresse IP est configurée sur un LAG ou un port physique (ex. : g10), cette interface est supprimée du VLAN 1. Configuration du chemin statique Pour gérer le périphérique à partir d'un réseau à distance, vous devez configurer un chemin statique, qui est l'adresse IP où les paquets sont envoyés lorsque  aucune entrée n'est trouvée dans les tables de périphériques. L'adresse IP configurée doit appartenir au même sous-réseau que celle des interfaces IP du  périphérique. Pour configurer un chemin statique, à l'invite du système, tapez la commande comme indiqué dans l'exemple de configuration ci-dessous, où 100.1.1.1  (masque 24) est la station de gestion spécifique et 100.1.1.10 est le chemin statique utilisé comme une passerelle par défaut.  Affectation d'adresses IP statiques sur une interface intrabande ¡ L'adresse IP à affecter à l'interface VLAN PowerConnect est 192.168.1.123 ¡ Le masque de sous-réseau IP du réseau est 255.255.255.0 ¡ L'adresse IP du chemin par défaut est 192.168.1.1 ¡ La chaîne de communauté SNMP de lecture/écriture est «private» (privée) REMARQUE : Avant de continuer, lisez les notes de mise à jour pertinentes à ce produit. Les notes de mise à jour peuvent être téléchargées sur le site  Web de support de Dell à l'adresse support.dell.com. REMARQUE : La configuration simple initiale tient compte des hypothèses suivantes :  REMARQUE : Dans le cas de cet exemple, les conditions suivantes doivent être remplies : console> enable console#configure console(config)# username admin password dell level 15 console(config)# interface vlan 1 console (config-if) # ip address 192.168.1.123 /24 console (config-if)#exit console (config)# ip default-gateway 192.168.1.1 console (config) # snmp-server community private rw console(config)# exit console# Vérification de l'adresse IP et de l'adresse de passerelle par défaut  Assurez-vous que l'adresse IP et la passerelle par défaut sont correctement assignées en exécutant la commande ci-dessous et en analysant le résultat : Commande console# show ip interface vlan 1 Sortie Adresse IP de la passerelle État activité  --------------------- ------------------ 192.168.1.1 Actif Adresse IP Interface Type Nom d'utilisateur Pour gérer le périphérique à distance, par exemple via une session SSH, Telnet ou l'interface Web, vous devez configurer un nom d'utilisateur. Pour obtenir le  contrôle administratif total du périphérique, utilisez le niveau de privilège le plus élevé (15). Pour plus d'informations sur le niveau de privilège, reportez-vous au «Guide de référence CLI». Le nom d'utilisateur configuré est saisi en tant que nom de connexion pour les sessions de gestion à distance. Pour configurer un nom d'utilisateur et un  niveau de privilège, tapez la commande à l'invite du système, comme indiqué dans l'exemple de configuration ci-dessous : console> enable console# configure console(config)# username admin password abc level 15 Chaînes de communauté SNMP Le protocole SNMP (Simple Network Management Protocol - protocole de gestion de réseau simple) fournit une méthode de gestion des périphériques réseau.  Les périphériques SNMP exécutent un logiciel local, appelé «agent». Les agents SNMP gèrent une liste de variables, qui sont utilisées pour gérer le  périphérique. Ces variables sont définies dans la MIB (base d'informations de gestion). La MIB affiche les variables gérées par l'agent. L'agent SNMP définit un  format de spécifications MIB ainsi que le format utilisé pour accéder aux informations sur le réseau. Les droits d'accès aux agents SNMP sont contrôlés par des  chaînes d'accès ainsi que par des chaînes de communauté SNMP. Le périphérique est compatible SNMP et contient un agent SNMP qui prend en charge un jeu de variables MIB standard et privées. Les développeurs des  stations de gestion ont besoin de la structure exacte de l'arborescence MIB et de la totalité des informations relatives aux variables MIB privées avant de  pouvoir gérer les MIB.  Tous les paramètres peuvent être gérés à partir de n'importe quelle plate-forme de gestion SNMP, à l'exception de l'adresse IP de la station de gestion SNMP,  du nom de la communauté et des droits d'accès. L'accès de gestion SNMP au périphérique est désactivé si aucune chaîne de communauté n'existe.  L'écran suivant présente la configuration par défaut du périphérique :  ------------------- ------------ ------------ 192.168.1.123 /24 VLAN 1 Statique REMARQUE : Nous vous recommandons de télécharger la dernière révision de la documentation utilisateur sur le site Web de support de Dell à  l'adresse support.dell.com. REMARQUE : Seul l'administrateur (super-utilisateur) possédant le niveau de privilège le plus élevé (15) est autorisé à gérer le périphérique via  l'interface du navigateur Web. REMARQUE : Le périphérique est fourni sans aucune chaîne de communauté configurée. Les protocoles SNMPv1 et SNMPv2 sont pris en charge sur le  périphérique. Cette section décrit les paramètres de configuration des protocoles SNMPv1/v2.  Console# show snmp Chaîne de communauté  Accès de communauté  Adresse IP --------------- ---------------- -----------------------------La chaîne de communauté, l'accès à la communauté et l'adresse IP peuvent être paramétrés via le terminal local lors de la procédure de configuration initiale. Les options de configuration SNMP sont les suivantes : l Community string (Chaîne de communauté). ¡ Read Only (lecture seule) — Indique que les membres de la communauté peuvent consulter des informations de configuration sans pouvoir les  modifier. ¡ Read/Write (lecture et écriture) — Indique que les membres de la communauté peuvent consulter et modifier des informations de configuration.  ¡ Super — Indique que les membres de la communauté ont un accès administration. l Configurable IP address (Adresse IP configurable). Si l'adresse IP n'est pas configurée, cela signifie que tous les membres de la communauté possédant  le même nom de communauté bénéficient des mêmes droits d'accès.  La norme actuellement utilisée consiste à se servir de deux chaînes de communauté pour le périphérique — l'une (publique) avec un accès en lecture seule et  l'autre (privée) avec un accès en lecture et en écriture. La chaîne publique permet aux stations de gestion autorisées d'extraire des objets MIB, tandis que la  chaîne privée permet aux stations de gestion autorisées d'extraire et de modifier des objets MIB. Lors de la configuration initiale, il est recommandé de configurer l'unité conformément aux exigences de l'administrateur réseau et liées à l'utilisation d'une  station de gestion SNMP. Configuration de SNMP Pour configurer une adresse IP et des chaînes de communauté d'une station SNMP pour les tables générales de routeurs du périphérique, effectuez la  procédure suivante : 1. À l'invite de la console, tapez la commande Enable. L'invite s'affiche sous la forme #. 2. Tapez la commande configure et appuyez sur .  3. En mode de configuration, tapez la commande de configuration SNMP avec les paramètres incluant le nom de la communauté (privée), les droits d'accès  de la communauté (lecture et écriture) et l'adresse IP, comme indiqué dans l'exemple ci-dessous : console# configure config(config)# snmp-server community private rw 11.1.1.2 Affichage des tables de communauté SNMP  Pour afficher l'adresse IP et les tables de communauté de la station SNMP : 1. À l'invite de la console, tapez la commande exit. L'invite s'affiche sous la forme #. Interruptions activées.  L'interruption d'authentification est activée.  Adresse dest. interruption Communauté dest. interruption  Version Contact système :  Emplacement système : 2. En mode Privileged Exec (EXEC privilégié), tapez la commande show comme indiqué dans l'exemple ci-dessous : Les paramètres configurés permettent de poursuivre la configuration du périphérique à partir d'un emplacement distant. Configuration avancée Cette section fournit des informations relatives à l'allocation dynamique d'adresses IP et à la gestion de la sécurité basées sur le mécanisme AAA  (Authentication, Authorization, Accounting). Les sujets suivants y sont traités :  l Configuration des adresses IP via DHCP l Configuration des adresses IP via BOOTP l Gestion de la sécurité et configuration du mot de passe Lors de la configuration/réception d'adresses IP via DHCP et BOOTP, la configuration reçue de la part de ces serveurs inclut l'adresse IP et éventuellement le  masque de sous-réseau et la passerelle par défaut.  Récupération d'une adresse IP à partir d'un serveur DHCP Lorsque le protocole DHCP est utilisé pour obtenir une adresse IP, le périphérique agit en tant que client DHCP. Lorsque le périphérique est réinitialisé, la  commande DHCP est enregistrée dans le fichier de configuration, mais pas l'adresse IP. Pour obtenir une adresse IP à partir d'un serveur DHCP : 1. Sélectionnez et connectez n'importe quel port au serveur DHCP ou à un sous-réseau possédant un serveur DHCP, de manière à obtenir l'adresse IP.  Console# show snmp Chaîne de communauté  Accès de communauté  Adresse IP --------------- ---------------- ----------------------------- privée  lecture écriture  11.1.1.2 Interruptions activées.  L'interruption d'authentification est activée.  Adresse dest. interruption Communauté dest. interruption  Version Contact système :  Emplacement système : 2. Tapez les commandes ci-après pour utiliser le port sélectionné pour la réception de l'adresse IP. Dans cet exemple, les commandes sont basées sur le  type de port utilisé pour la configuration.  l Allocation d'adresses IP dynamiques : console# configure console(config)# interface ethernet g1 console(config-if)# ip address dhcp hostname device console(config-if)# exit console(config)# l Affectation d'adresses IP dynamiques (sur un VLAN) : console# configure console(config)# interface ethernet vlan 1 console(config-if)# ip address dhcp hostname device console(config-if)# exit console(config)# 3.  Pour vérifier l'adresse IP, tapez la commande show ip interface à l'invite du système, comme dans l'exemple ci-après.  Console# show ip interface Adresse IP de la passerelle État activité  --------------------- ------------------ 10.7.1.1 Actif Adresse IP Interface Type ------------------- ------------ ------------ 10.7.1.192/24 VLAN 1 Statique Réception d'une adresse IP à partir d'un serveur BOOTP Le protocole standard BOOTP est pris en charge, ce qui permet au périphérique de télécharger automatiquement la configuration IP de son hôte à partir de  n'importe quel serveur BOOTP standard sur le réseau. Dans ce cas, le périphérique joue le rôle d'un client BOOTP.  Pour obtenir une adresse IP à partir d'un serveur BOOTP : 1. Sélectionnez et connectez n'importe quel port à un serveur BOOTP ou à un sous-réseau contenant ce type de serveur de manière à obtenir l'adresse  IP. 2. À l'invite du système, tapez la commande delete startup configuration pour supprimer la configuration de démarrage de la mémoire Flash.  Le périphérique se réamorce sans configuration et envoie des requêtes BOOTP au bout de 60 secondes. Le périphérique reçoit automatiquement  l'adresse IP. L'exemple suivant présente le processus : console> enable console# delete startup-config Le fichier de démarrage a été supprimé console# reload Vous n'avez pas enregistré vos modifications. Êtes-vous certain de vouloir continuer (y/n) [n] ? Cette commande réinitialisera tout le système et vous déconnectera de la session en cours. Êtes-vous certain de vouloir continuer (y/n) [n] ? ****************************************************** /* redémarrage du commutateur */ Pour vérifier l'adresse IP, tapez la commande show ip interface. Le périphérique est maintenant paramétré avec une adresse IP. Gestion de la sécurité et configuration du mot de passe La sécurité du système est traitée via le mécanisme AAA (Authentication, Authorization, and Accounting) qui gère les droits d'accès des utilisateurs, les  privilèges et les méthodes de gestion. AAA utilise des bases de données utilisateur à la fois locales et distantes. Le cryptage des données est traité via le  mécanisme SSH. Le système est livré sans mot de passe par défaut configuré : Les mots de passe sont tous définis par l'utilisateur. Si un mot de passe défini par l'utilisateur  est perdu, une procédure de récupération du mot de passe peut être lancée à partir du menu Démarrer. Cette procédure est disponible uniquement sur le  terminal local et permet d'accéder une seule fois au périphérique sans saisir de mot de passe. 10.7.2.192/24 VLAN 2 DHCP REMARQUE : Il n'est pas nécessaire de supprimer la configuration du périphérique pour obtenir une adresse IP à partir du serveur DHCP.  REMARQUE : Lorsque vous copiez des fichiers de configuration, évitez d'utiliser un fichier de configuration contenant une instruction permettant  d'activer le protocole DHCP sur une interface reliée au même serveur DHCP ou à un serveur possédant la même configuration. Dans cet exemple, le  périphérique obtient le nouveau fichier de configuration et l'utilise pour démarrer. Le périphérique active ensuite le DHCP comme il est demandé dans le  nouveau fichier de configuration et le DHCP lui demande de charger à nouveau le même fichier.  REMARQUE : Une fois que l'amorçage du périphérique a commencé, le fait d'entrer des données sur le terminal ASCII ou sur le clavier fait avorter le  processus et le périphérique ne reçoit pas d'adresse IP de la part du serveur BOOTP. Configuration de mots de passe de sécurité Vous pouvez configurer des mots de passe de sécurité pour les services suivants : l Terminal l Telnet l SSH l HTTP l HTTPS Configuration d'un mot de passe terminal initial Pour configurer un mot de passe terminal initial, entrez les commandes suivantes : console(config)# aaa authentication login default line console(config)# aaa authentication enable default line console(config)# line console console(config-line)# login authentication default console(config-line)# enable authentication default console(config-line)# password george l Lorsque vous vous connectez à un périphérique pour la première fois via une session de terminal, tapez george à l'invite du mot de passe. l Lorsque vous modifiez le mode du périphérique de disable (désactiver) à enable (activer), tapez george à l'invite du mot de passe. Configuration d'un mot de passe Telnet initial Pour configurer un mot de passe Telnet initial, tapez les commandes suivantes : console(config)# aaa authentication login default line console(config)# aaa authentication enable default line console(config)# line telnet console(config-line)# login authentication default console(config-line)# enable authentication default console(config-line)# password bob l Lorsque vous vous connectez à un périphérique pour la première fois via une session Telnet, tapez bob à l'invite du mot de passe.  l Lorsque vous modifiez le mode du périphérique de disable (désactiver) à enable (activer), tapez bob. REMARQUE : Les mots de passe sont définis par l'utilisateur.  REMARQUE : Lors de la création d'un nom d'utilisateur, la priorité par défaut est 1, ce qui signifie que l'utilisateur peut accéder au système mais pas  aux fonctions de configuration. L'accès à la configuration n'est possible que si le niveau de priorité 15 a été défini. Même si les noms d'utilisateur  peuvent avoir le niveau de privilège 15 sans mot de passe nécessaire, il est recommandé de leur en assigner un automatiquement. Si aucun mot de  passe n'est défini, les utilisateurs privilégiés peuvent accéder à l'interface Web sans mot de passe. Configuration d'un mot de passe SSH initial Pour configurer un mot de passe SSH initial, tapez les commandes suivantes : console(config)# aaa authentication login default line console(config)# aaa authentication enable default line console(config)# line ssh console(config-line)# login authentication default console(config-line)# enable authentication default console(config-line)# password jones. l Lorsque vous vous connectez à un périphérique pour la première fois via une session SSH, tapez jones à l'invite du mot de passe. l Lorsque vous modifiez le mode du périphérique de disable (désactiver) à enable (activer), tapez jones. Configuration d'un mot de passe HTTP initial Pour configurer un mot de passe HTTP initial,